ENS.prg
INFO
| Field |
Value |
| ECU |
Ethernet-Switch |
| ORIGIN |
BMW EI-400 Baumgartner |
| REVISION |
1.000 |
| AUTHOR |
BMW EE-420 Loewe |
| COMMENT |
- |
| PACKAGE |
1.68 |
| SPRACHE |
deutsch |
Jobs
Index
- INFO - Information SGBD
- INITIALISIERUNG - Initialisierung und Kommunikationsparameter
- IDENT - Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
- FS_LESEN - Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
- FS_LESEN_DETAIL - Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
- FS_LOESCHEN - Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
- PRUEFSTEMPEL_LESEN - Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
- PRUEFSTEMPEL_SCHREIBEN - Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
- SVK_LESEN - Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
- STATUS_LESEN - Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
- STEUERN - Vorgeben eines Status UDS : $2E WriteDataByIdentifier
- SERIENNUMMER_LESEN - Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
- STEUERN_ROUTINE - Vorgeben eines Status UDS : $31 RoutineControl
- FS_SPERREN - Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
- IS_LESEN - Sekundaerer Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $22 ReadDataByIdentifierRequestServiceID UDS : $2000 DataIdentifier sekundaerer Fehlerspeicher Modus: Default
- IS_LESEN_DETAIL - sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $22 ReadDataByIdentifier UDS : $20 dataIdentifier UDS : $00 alle Info-Meldungen anschließend UDS : $20 dataIdentifier UDS : $nn Details zur Info-Meldung an der Position n Modus: Default
- IS_LOESCHEN - Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default
- HERSTELLINFO_LESEN - Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
- DIAGNOSE_AUFRECHT - Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
- DIAGNOSE_MODE - SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
- SLEEP_MODE - SG in Sleep-Mode versetzen UDS : $11 ECUReset UDS : $04 EnableRapidPowerShutDown Modus: Default
- ENERGIESPARMODE - Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
- STATUS_ENERGIESPARMODE - Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
- STATUS_BETRIEBSMODE - Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default
- STEUERN_BETRIEBSMODE - Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default
- STEUERGERAETE_RESET - Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
- STATUS_ROE_REPORT - Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS: $86 ResponseOnEvent $04 report activated events $02 eventWindowTime - infinite (LH Diagnosemaster V11 oder höher, Umsetzung nach LH V6 - V10 wird jedoch toleriert)
- STEUERN_ROE_PERSISTENT_STOP - Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
- STEUERN_ROE_PERSISTENT_START - Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
- STATUS_ETH_SIGNAL_QUALITY - Returns the signal quality of all external ports of the ECU UDS : $22 ReadDataByIdentifier $1801 ETH_SIGNAL_QUALITY
- STEUERN_ETH_LEARN_PORT_CONFIGURATION - Stores the current link state (link up/link down) of all external ports of the ecu. The stored port configuration can then be used to detect missing, or additional ECUs during runtime. UDS : $31 RoutineControl $01 StartRoutine $1040
- STATUS_ETH_READ_PHY_REGISTER - Reads an arbitrary PHY, MAC or switch register. UDS : $31 RoutineControl $01 StartRoutine $1041
- STATUS_ETH_ARL_TABLE - Shall return the ARP table of a given network interface. The interface shall be identified by its IP address. UDS : $31 RoutineControl $01 StartRoutine $1042
- STATUS_ETH_ARP_TABLE - Shall return the ARP table of a given network interface. The interface shall be identified by its IP address. UDS : $31 RoutineControl $01 StartRoutine $1043
- STEUERN_ETH_PHY_SWITCH_ENGINE_RESET - Requests the reset of a given PHY or of the ECUs switch(es). If supported by the ECU, the PHY/switch(es) may be held in reset for a given amount of time. If an ECU does not support holding the PHY/switch(es) in reset for a given duration but STOP_PHY_FOR_T is greater than 0, the job shall quit with return value STAT_PHY_RESET = 2 and without performing the reset. After the reset, the default configuration, i.e., the configuration that is used during runtime, shall be applied. UDS : $31 RoutineControl $01 StartRoutine $1044
- STATUS_ETH_IP_CONFIGURATION - Shall return the ARP table of a given network interface. The interface shall be identified by its IP address. UDS : $31 RoutineControl $01 StartRoutine $1045
- STEUERN_ETH_WRITE_PHY_REGISTER - Writes an arbitrary PHY, MAC or switch register. UDS : $31 RoutineControl $01 StartRoutine $104D
INFO
Information SGBD
No arguments.
Results
| Name |
Type |
Comment |
| ECU |
string |
Steuergerät im Klartext |
| ORIGIN |
string |
Steuergeräte-Verantwortlicher |
| REVISION |
string |
Versions-Nummer |
| AUTHOR |
string |
Namen aller Autoren |
| COMMENT |
string |
wichtige Hinweise |
| PACKAGE |
string |
Include-Paket-Nummer |
| SPRACHE |
string |
deutsch, english |
INITIALISIERUNG
Initialisierung und Kommunikationsparameter
No arguments.
Results
| Name |
Type |
Comment |
| DONE |
int |
1, wenn Okay |
IDENT
Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| ID_SG_ADR |
long |
Steuergeraeteadresse |
| ID_SGBD_INDEX |
long |
Index zur Erkennung der SG-Variante |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
FS_LESEN
Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
Arguments
| Name |
Type |
Comment |
| IGNORIERE_EREIGNIS_DTC |
string |
'IGNORIERE_EREIGNIS_DTC': Alle Ereignis DTC-Fehlereinträge werden ignoriert sonst: alle Fehlereinträge werden ausgegeben |
Results
| Name |
Type |
Comment |
| F_VERSION |
int |
Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE |
binary |
Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR |
long |
Index fuer Fehlerort |
| F_ORT_TEXT |
string |
Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC |
int |
0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_STATUSBYTE |
int |
Wert des DTC-Statusbyte laut ISO 14229 (bitcodiert) Bedeutung der einzelnen Bits: Bit 7: warningIndicatorRequested Bit 6: testNotCompletedThisOperationCycle Bit 5: testFailedSinceLastClear Bit 4: testNotCompletedSinceLastClear Bit 3: ConfirmedDTC Bit 2: PendingDTC Bit 1: testFailedThisOperationCycle Bit 0: testFailed |
| F_READY_NR |
int |
Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT |
string |
Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR |
int |
Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT |
string |
Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR |
int |
Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT |
string |
Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
FS_LESEN_DETAIL
Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
Arguments
| Name |
Type |
Comment |
| F_CODE |
long |
gewaehlter Fehlercode |
Results
| Name |
Type |
Comment |
| F_VERSION |
int |
Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE |
binary |
Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR |
long |
Index fuer Fehlerort |
| F_ORT_TEXT |
string |
Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC |
int |
0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_STATUSBYTE |
int |
Wert des DTC-Statusbyte laut ISO 14229 (bitcodiert) Bedeutung der einzelnen Bits: Bit 7: warningIndicatorRequested Bit 6: testNotCompletedThisOperationCycle Bit 5: testFailedSinceLastClear Bit 4: testNotCompletedSinceLastClear Bit 3: ConfirmedDTC Bit 2: PendingDTC Bit 1: testFailedThisOperationCycle Bit 0: testFailed |
| F_READY_NR |
int |
Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT |
string |
Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR |
int |
Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT |
string |
Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR |
int |
Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT |
string |
Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_HFK |
int |
Haeufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf |
| F_HLZ |
int |
Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Heilungsszaehler |
| F_UEBERLAUF |
int |
0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers |
| F_FEHLERKLASSE_NR |
int |
0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich ! |
| F_FEHLERKLASSE_TEXT |
string |
Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT |
| F_UW_ANZ |
int |
Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung |
| F_UW_KM |
long |
Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht |
| F_UW_ZEIT |
long |
Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_UW_BN |
int |
Umweltbedingung Basisnetz (1 Byte) -1, wenn Daten bzgl. Basisnetz nicht zur Verfuegung stehen |
| F_UW_TN |
long |
Umweltbedingung Teilnetz (3 Byte) -1, wenn Daten bzgl. funktionalem Teilnetz nicht zur Verfuegung stehen |
| F_SAE_CODE |
unsigned int |
Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD |
| F_SAE_CODE_STRING |
string |
5 stelliger Text in der Form 'Sxxxx' |
| F_SAE_CODE_TEXT |
string |
Text zu F_SAE_CODE |
| _RESPONSE_SNAPSHOT |
binary |
Hex-Antwort von SG |
| _RESPONSE_EXTENDED_DATA |
binary |
Hex-Antwort von SG |
| _RESPONSE_SEVERITY |
binary |
Hex-Antwort von SG |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
FS_LOESCHEN
Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
Arguments
| Name |
Type |
Comment |
| F_CODE |
long |
0x??????: Angabe eines einzelnen Fehlers Default: 0xFFFFFF: alle Fehler |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
PRUEFSTEMPEL_LESEN
Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| BYTE1 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE2 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE3 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
PRUEFSTEMPEL_SCHREIBEN
Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
Arguments
| Name |
Type |
Comment |
| BYTE1 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE2 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE3 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
SVK_LESEN
Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
Arguments
| Name |
Type |
Comment |
| SVK |
string |
table SVK_ID BEZEICHNUNG WERT default SVK_AKTUELL |
Results
| Name |
Type |
Comment |
| PROG_TEST |
int |
Programmierabhaengigkeiten (ProgrammingDependenciesChecked) 1: IO : Signaturpruefung und ProgrammingDependenciesCheck erfolgreich 2: NIO: mindestens eine SWE fehlerhaft oder ProgrammingDependenciesCheck nicht durchgefuehrt 3: NIO: mindestens eine SWE passt nicht mit einer HWE zusammen 4: NIO: mindestens eine SWE passt nicht mit einer anderen SWE zusammen sonst: reserviert |
| ANZAHL_EINHEITEN |
int |
Anzahl der xWEn |
| PROG_DATUM |
string |
Programmierdatum (DD.MM.YY) |
| PROG_KM |
long |
KM-Stand bei Programmierung (10 KM bis 655350 KM) Inkrement sind 10 KM -1: KM-Stand wird nicht unterstuetzt |
| PROZESSKLASSE_WERT |
int |
table Prozessklassen WERT dezimale Angabe der Prozessklasse |
| PROZESSKLASSE_TEXT |
string |
table Prozessklassen BEZEICHNUNG Text-Angabe der Prozessklasse |
| PROZESSKLASSE_KURZTEXT |
string |
table Prozessklassen PROZESSKLASSE Text-Angabe des Prozessklassenkurztextes |
| SGBM_IDENTIFIER |
string |
Angabe SGBM-ID der Prozessklasse |
| VERSION |
string |
Angabe der Version der Prozessklasse |
| SGBM_ID |
string |
Angabe von Prozessklasse, SGBM-Identifier, Version |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STATUS_LESEN
Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
Arguments
| Name |
Type |
Comment |
| ARGUMENT_SPALTE |
string |
'ARG', 'ID', 'LABEL' |
| STATUS |
string |
Es muss mindestens ein Argument übergeben werden Es wird das zugehörige result erzeugt table SG_Funktionen ARG ID RESULTNAME RES_TABELLE ARG_TABELLE |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Antwort von SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN
Vorgeben eines Status UDS : $2E WriteDataByIdentifier
Arguments
| Name |
Type |
Comment |
| ARGUMENT_SPALTE |
string |
'ARG', 'ID', 'LABEL' |
| STATUS |
string |
Siehe table SG_Funktionen ARG ID LABEL ARG_TABELLE |
| WERT |
string |
Es muss mindestens ein Argument übergeben werden Argumente siehe table SG_Funktionen ARG ID ARG_TABELLE |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Antwort von SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
SERIENNUMMER_LESEN
Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| SERIENNUMMER |
string |
Seriennummer des Steuergeraets |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN_ROUTINE
Vorgeben eines Status UDS : $31 RoutineControl
Arguments
| Name |
Type |
Comment |
| ARGUMENT_SPALTE |
string |
'ARG', 'ID', 'LABEL' |
| STATUS |
string |
Siehe table SG_Funktionen ARG ID RES_TABELLE ARG_TABELLE |
| STEUERPARAMETER |
string |
'STR' = startRoutine 'STPR' = stopRoutine 'RRR' = requestRoutineResults |
| WERT |
string |
Argumente siehe table SG_Funktionen ARG_TABELLE |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Antwort von SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
FS_SPERREN
Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
Arguments
| Name |
Type |
Comment |
| SPERREN |
string |
"ja" -> Fehlerspeicher sperren "nein" -> Fehlerspeicher freigeben table DigitalArgument TEXT Default: "ja" |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
IS_LESEN
Sekundaerer Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $22 ReadDataByIdentifierRequestServiceID UDS : $2000 DataIdentifier sekundaerer Fehlerspeicher Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| F_VERSION |
int |
Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE |
binary |
Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR |
long |
Index fuer Fehlerort |
| F_ORT_TEXT |
string |
Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC |
int |
0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_STATUSBYTE |
int |
Wert des DTC-Statusbyte laut ISO 14229 (bitcodiert) Bedeutung der einzelnen Bits: Bit 7: warningIndicatorRequested Bit 6: testNotCompletedThisOperationCycle Bit 5: testFailedSinceLastClear Bit 4: testNotCompletedSinceLastClear Bit 3: ConfirmedDTC Bit 2: PendingDTC Bit 1: testFailedThisOperationCycle Bit 0: testFailed |
| F_READY_NR |
int |
Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT |
string |
Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR |
int |
Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT |
string |
Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR |
int |
Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT |
string |
Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
IS_LESEN_DETAIL
sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $22 ReadDataByIdentifier UDS : $20 dataIdentifier UDS : $00 alle Info-Meldungen anschließend UDS : $20 dataIdentifier UDS : $nn Details zur Info-Meldung an der Position n Modus: Default
Arguments
| Name |
Type |
Comment |
| F_CODE |
long |
gewaehlter Infocode Wenn dieser Parameter angegeben wird, wird die Position automatisch ermittelt. Es darf dann nicht argument F_POS angegeben werden |
| F_POS |
int |
gewaehlter Eintrag Wenn dieser Parameter angegeben wird, wird die Position benutzt. Wertebereich 1 - 255 Es darf dann nicht argument F_CODE angegeben werden |
Results
| Name |
Type |
Comment |
| F_VERSION |
int |
Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE |
binary |
Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR |
long |
Index fuer Fehlerort |
| F_ORT_TEXT |
string |
Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC |
int |
0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_STATUSBYTE |
int |
Wert des DTC-Statusbyte laut ISO 14229 (bitcodiert) Bedeutung der einzelnen Bits: Bit 7: warningIndicatorRequested Bit 6: testNotCompletedThisOperationCycle Bit 5: testFailedSinceLastClear Bit 4: testNotCompletedSinceLastClear Bit 3: ConfirmedDTC Bit 2: PendingDTC Bit 1: testFailedThisOperationCycle Bit 0: testFailed |
| F_READY_NR |
int |
Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT |
string |
Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR |
int |
Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT |
string |
Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR |
int |
Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT |
string |
Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_HFK |
int |
Haeufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf |
| F_HLZ |
int |
Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Heilungsszaehler |
| F_UEBERLAUF |
int |
0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers |
| F_FEHLERKLASSE_NR |
int |
0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich ! |
| F_FEHLERKLASSE_TEXT |
string |
Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT |
| F_UW_ANZ |
int |
Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung |
| F_UW_KM |
long |
Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht |
| F_UW_ZEIT |
long |
Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_UW_BN |
int |
Umweltbedingung Basisnetz (1 Byte) -1, wenn Daten bzgl. Basisnetz nicht zur Verfuegung stehen |
| F_UW_TN |
long |
Umweltbedingung Teilnetz (3 Byte) -1, wenn Daten bzgl. funktionalem Teilnetz nicht zur Verfuegung stehen |
| F_SAE_CODE |
unsigned int |
Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD |
| F_SAE_CODE_STRING |
string |
5 stelliger Text in der Form 'Sxxxx' |
| F_SAE_CODE_TEXT |
string |
Text zu F_SAE_CODE |
| _RESPONSE_2000 |
binary |
Hex-Antwort von SG |
| _RESPONSE_200X |
binary |
Hex-Antwort von SG |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
IS_LOESCHEN
Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
HERSTELLINFO_LESEN
Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| ID_LIEF_NR |
long |
Lieferantennummer 0xFFFFFF, falls nicht vorhanden |
| ID_LIEF_TEXT |
string |
Text zu ID_LIEF_NR table Lieferanten LIEF_TEXT unbekannter Hersteller, falls nicht vorhanden |
| ID_DATUM |
string |
Herstelldatum (DD.MM.YY) |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
| _REQUEST_2 |
binary |
Hex-Auftrag an SG |
| _RESPONSE_2 |
binary |
Hex-Antwort von SG |
DIAGNOSE_AUFRECHT
Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
Arguments
| Name |
Type |
Comment |
| SG_ANTWORT |
string |
"ja" -> SG soll antworten "nein" -> SG soll nicht antworten table DigitalArgument TEXT Default: SG soll antworten |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
DIAGNOSE_MODE
SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
Arguments
| Name |
Type |
Comment |
| MODE |
string |
gewuenschter Diagnose-Modus table DiagMode MODE MODE_TEXT Defaultwert: DEFAULT (DefaultMode) |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
SLEEP_MODE
SG in Sleep-Mode versetzen UDS : $11 ECUReset UDS : $04 EnableRapidPowerShutDown Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
ENERGIESPARMODE
Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
Arguments
| Name |
Type |
Comment |
| MODE |
int |
0x00: Normalmode 0x01: Fertigungsmode 0x02: Transportmode 0x03: Flashmode |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STATUS_ENERGIESPARMODE
Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| STAT_ENERGIESPARMODE_WERT |
int |
Ausgabe des Energiesparmodes 0: Kein Energiesparmode gesetzt 1: Produktionsmode gesetzt 2: Transportmode gesetzt 3: Flashmode gesetzt -1: Mode ungueltig |
| STAT_ENERGIESPARMODE_TEXT |
string |
Text zu STAT_ENERGIESPARMODE_WERT |
| STAT_PRODUKTIONSMODE_EIN |
int |
0: Produktionsmode nicht aktiv 1: Produktionsmode aktiv |
| STAT_TRANSPORTMODE_EIN |
int |
0: Transportmode nicht aktiv 1: Transportmode aktiv |
| STAT_FLASHMODE_EIN |
int |
0: Flashmode nicht aktiv 1: Flashmode aktiv |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STATUS_BETRIEBSMODE
Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| STAT_BETRIEBSMODE_WERT |
int |
Aktueller Betriebsmode table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle) |
| STAT_BETRIEBSMODE_TEXT |
string |
Textausgabe STAT_BETRIEBSMODE_WERT table Betriebsmode TEXT |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN_BETRIEBSMODE
Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default
Arguments
| Name |
Type |
Comment |
| BETRIEBSMODE |
int |
Betriebsmode setzen table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle) |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERGERAETE_RESET
Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STATUS_ROE_REPORT
Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS: $86 ResponseOnEvent $04 report activated events $02 eventWindowTime - infinite (LH Diagnosemaster V11 oder höher, Umsetzung nach LH V6 - V10 wird jedoch toleriert)
No arguments.
Results
| Name |
Type |
Comment |
| STAT_ROE_AKTIV |
char |
0x00 = Aktive Fehlermeldung deaktiviert 0x01 = Aktive Fehlermeldung aktiviert 0xFF = Status der aktiven Fehlermeldung nicht feststellbar |
| STAT_ROE_AKTIV_TEXT |
string |
Interpretation von STAT_ROE_AKTIV table UDS_TAB_ROE_AKTIV TEXT |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN_ROE_PERSISTENT_STOP
Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
No arguments.
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN_ROE_PERSISTENT_START
Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
No arguments.
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STATUS_ETH_SIGNAL_QUALITY
Returns the signal quality of all external ports of the ECU UDS : $22 ReadDataByIdentifier $1801 ETH_SIGNAL_QUALITY
No arguments.
Results
| Name |
Type |
Comment |
| STAT_SIGNAL_QUALITY_ARRAY |
binary |
Array containing the signal quality of all external ports. Each entry shall contain the signal quality of the corresponding port, normalized to a percentual value. Length of each entry: 1 byte uint8 {0xff = signal quality could not be estimated or link is down or port is not connected, 0-100= percentual signal quality normalized to a percentual value (100%= highest quality, 0%= lowest quality).} |
| STAT_PORT_NUMBER |
unsigned char |
Port Number (0 - 7) |
| STAT_SIGNAL_QUALITY_PERCENT |
string |
Quality of port in percent (decimal) |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN_ETH_LEARN_PORT_CONFIGURATION
Stores the current link state (link up/link down) of all external ports of the ecu. The stored port configuration can then be used to detect missing, or additional ECUs during runtime. UDS : $31 RoutineControl $01 StartRoutine $1040
No arguments.
Results
| Name |
Type |
Comment |
| STAT_LEARN_PORT_CONFIGURATION |
unsigned char |
Learning of port configuration was successful/failed. 1 byte uint8 {0= Learning of port configuration successful, 1= Learning of port configuration failed} |
| STAT_PORT_CONFIGURATION |
binary |
Array containing the stored link state (link up/link down). The size of the array must be a multiple of 1 Byte. (array is bit coded) Length of each entry: 1 Bit {0= Link-down, i.e., no link expected during runtime, or port configuration has not been learned yet. 1= Link-up, i. e., link expected during runtime} |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STATUS_ETH_READ_PHY_REGISTER
Reads an arbitrary PHY, MAC or switch register. UDS : $31 RoutineControl $01 StartRoutine $1041
Arguments
| Name |
Type |
Comment |
| INPUTDATA |
binary |
1st byte: REG_READ_RANGE: Number of registers that shall be read (enumeration starts at 1). {uint8, 0= no write, 1-255= write 1 to 255 registers } --------- followed by: REG_ADDR[] - each entry 4byte uint32. Addresses to be read from. If the number of provided addresses is not equal to REG_READ_RANGE, the job execution shall be aborted. Each address must be converted to a unique PHY, MAC or switch register address. The conversion shall be handled individually by each ECU. The used mapping scheme shall take into account all available PHYs, MACs and switches the ECU is equipped with and that are visible externally, i.e., via an connector. --------- followed by 1 byte: REG_READ_RANGE: Number of registers that shall be read (enumeration starts at 1). {uint8, 0= no write, 1-255= write 1 to 255 registers } --------- followed by: REG_READ_LENGTH[] - each entry 1 byte uint8. Entry n in REG_READ_LENGTH[] specifies how many bytes shall be read from the register address defined by entry n in REG_ADDR[]. Enumeration shall start at 1. If the number of entries is not equal to REG_READ_RANGE, the job execution shall be aborted. |
Results
| Name |
Type |
Comment |
| STAT_REG_READ_OK |
unsigned char |
Shall indicate, whether reading from the requested registers was successful. { 0 =read ok, 1 = read not ok } |
| STAT_REG_READ_DATA |
binary |
If REG_READ_OK=0: shall return the values of the registers defined by REG_ADDR[]. Each array entry corresponds to one register read. The number of bytes that shall be read is defined by the corresponding entry in REG_READ_LENGTH[]. If the length that is to be read for a given entry is smaller than 8 bytes, the upper bytes of this entry shall be set to 0. {0 - 0xffffffffffffffff} |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STATUS_ETH_ARL_TABLE
Shall return the ARP table of a given network interface. The interface shall be identified by its IP address. UDS : $31 RoutineControl $01 StartRoutine $1042
Arguments
| Name |
Type |
Comment |
| PORT_INDEX |
unsigned char |
Port index of the requested ARL table. The ARL table of all external ports of the ECU shall be returned if PORT_INDEX=0xff. 1 byte uint8 {Port 0 - Port n-1 (for n Ports total), 0xff = ARL table of all ports.} |
Results
| Name |
Type |
Comment |
| STAT_NUM_ARL_VLAN_ID_ENTRIES_WERT |
unsigned char |
Shall return the number of following ARL entries. uint8 {0 = no entries, 0xff= requested port does not exist, 0x01-0xfe= Number of ARL entries (starting at 1)} |
| STAT_ARL_VLAN_ID_ENTRIES |
binary |
Array containing all ARL entries for the given port or for all external ports, respectively. Each entry shall contain one complete ARL table entry consisting of the 4 bit long port index, the 12 bit long VLAN-ID and the 6 byte long MAC address. Each entry: 8 bytes uint64 byte[0-5]= MAC address (starting with the MAC address least significant byte in byte[0] and ending with the most significant byte in byte[5]), byte[6]= bits 7-0 of the VLAN-ID, lower 4 bits of byte[7]= bits 11 -8 of the VLAN-ID, upper 4 bits of byte[7]= port index. |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STATUS_ETH_ARP_TABLE
Shall return the ARP table of a given network interface. The interface shall be identified by its IP address. UDS : $31 RoutineControl $01 StartRoutine $1043
Arguments
| Name |
Type |
Comment |
| INPUTDATA |
binary |
1st byte, uint8: IP_VERSION_TAB Used IP version of the network interface for which the ARP table shall be returned. IP_VERSION_TAB = 0 if the entry uses IPv4, IP_VERSION_TAB = 1 if the entry uses IPv6. --------- followed by 16 bytes ARP_TABLE_FOR_IP_ADDRESS: IP address of the network interface for which the ARP table shall be returned. IP address starting with the first octet (e.g., byte[0]=0xC0, byte[1]=0xA8, byte[2]=0x00, byte[3]=0x01 for IP address 192.168.0.1) For IPv4: byte[0] - byte[3]=IPv4 address, byte[4-15]=0. For IPv6: byte[0-15]=IPv6 address. --------- |
Results
| Name |
Type |
Comment |
| STAT_NUM_ARP_ENTRIES |
unsigned char |
Shall return the number of following ARP entries. {0 = no entries, 1-0xff = number of ARP entries} |
| STAT_ARP_IP_MAC_ENTRIES |
binary |
Array containing all ARP entries for the requested network interface. Each entry shall contain the IP address, the used IP version and the corresponding MAC address. 23 bytes byte[0]= 0 if the entry uses IPv4, byte[0]= 1 if the entry uses IPv6. For IPv4: byte[1] - byte[4] = IPv4 address starting with the first octet (e.g., byte[1]=0xC0, byte[2]=0xA8, byte[3]=0x00, byte[4]=0x01 for IP address 192.168.0.1), byte[5-16]=0. For IPv6: byte[1-16] = IPv6 address starting with the first octet. byte[17-22]=MAC address. |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN_ETH_PHY_SWITCH_ENGINE_RESET
Requests the reset of a given PHY or of the ECUs switch(es). If supported by the ECU, the PHY/switch(es) may be held in reset for a given amount of time. If an ECU does not support holding the PHY/switch(es) in reset for a given duration but STOP_PHY_FOR_T is greater than 0, the job shall quit with return value STAT_PHY_RESET = 2 and without performing the reset. After the reset, the default configuration, i.e., the configuration that is used during runtime, shall be applied. UDS : $31 RoutineControl $01 StartRoutine $1044
Arguments
| Name |
Type |
Comment |
| PORT_INDEX |
unsigned char |
Port Index {0-0xfe = Port 0 - Port 254, 0xff = reset all switch engines} |
| STOP_PHY_FOR_T |
unsigned char |
Amount of time the PHY or switch(es) shall be hold in reset. 0 - 255 seconds |
Results
| Name |
Type |
Comment |
| STAT_PHY_RESET |
unsigned char |
Shall indicate, whether the reset was successful or not. {0=reset successful, 1= reset not successful, 2= reset not triggered because STOP_PHY_FOR_T > 0 is not supported for the given port/switch(es)} |
| STAT_PHY_RESET_TEXT |
string |
Shall indicate, whether the reset was successful or not. {reset successful, reset not successful, reset not triggered because STOP_PHY_FOR_T > 0 is not supported for the given port/switch(es)} |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STATUS_ETH_IP_CONFIGURATION
Shall return the ARP table of a given network interface. The interface shall be identified by its IP address. UDS : $31 RoutineControl $01 StartRoutine $1045
Arguments
| Name |
Type |
Comment |
| INTERNAL_EXTERNAL_ADDRESS |
unsigned char |
Identifies the network interface and its corresponding IP address (internal, external, all, further, optional application specific address) for which the IP configuration shall be returned and for which an optional gratuitous ARP shall be triggered. 1 byte uint8 {0= request internal IP address, 1= request external IP address (assigned by tester, cf. [100]) 0xff = request all IP-addresses, else = further, application specific IP address} |
| TRIGGER_GRATUITOUS_ARP |
unsigned char |
Defines whether the ECU shall send out a gratuitous ARP for the requested network interface. The gratuitous ARP shall be sent as soon as possible after being triggered. 1 byte uint8 {1= send gratuitous ARP for the requested network interface, else = do not send gratuitous ARP} |
Results
| Name |
Type |
Comment |
| STAT_ECU_TYPE |
unsigned char |
Returns whether the ECU is equipped with a switch, how the switch is used and what type of Ethernet-ports the ECU is equipped with. This parameter is independent of the selected network interface. The return value is coded as a bit field. Each bit either refers to a given port type or indicates whether the ECU is equipped with a switch and how the switch is used. The different bits shall be ORed if the corresponding conditions are met. 1 byte uint8 Decoding of bitcoded value STAT_ECU_TYPE: Bit (Bitmask) Shall be set if: Bit 0 (0x01) ECU is not equipped with a switch. Bit 1 (0x02) ECU is equipped with a switch that is (also) connected to at least one regular external port (cf. ETH_SYS_DIAG_131). If this bit is set, the ECU must support RC ETH_ARL_TABLE (ETH_SYS_DIAG_87). Bit 2 (0x04) ECU is equipped with a switch that is (also) connected to at least one external special-function port (cf. ETH_SYS_DIAG_140). If this bit is set, the ECU must support ETH_EXTENDED_ARL_TABLE (ETH_SYS_DIAG_147). Bit 3 (0x08) ECU is equipped with a switch that is (also) used internally. Bit 4 (0x10) ECU has at least one regular external port (ETH_SYS_DIAG_131). Bit 5 (0x20) ECU has at least one external special function port (ETH_SYS_DIAG_140). Bit 6 (0x40) reserved Bit 7 (0x80) reserved |
| STAT_IP_CONFIGURATION |
binary |
For INTERNAL_EXTERNAL_ADDRESS != 0xff: Array with one entry only. The entry contains either the internal, the external, or an optional, function specific IP address. The used IP version, network mask, the routers IP address and MAC address of the corresponding interface are part of this entry. If no external IP address has been assigned but the external IP address has been requested, all bytes of the entry shall be set to 0. For INTERNAL_EXTERNAL_ADDRESS == 0xff: Array containing all IP addresses of the ECU (1 to n). Each entry includes the used IP version, the network mask, the routers IP address and MAC address of the corresponding interfaces. The Array always contains the ECUs internal (array index 0) and external (array index 1) IP address. If no external address has been assigned, all bytes of the entry shall be set to 0. If applicable, entries 2 to n-1 contain optional, function specific IP addresses. The number of additional function specific IP addresses depends on the ECU, i.e., the value of n depends on the functionality of the ECU. byte[0 - 54] - 55 bytes IP address, network mask, router IP address (if applicable) and MAC address. byte[0]= 0 if the entry uses IPv4, byte[0]= 1 if the entry uses IPv6. For IPv4: byte[1] - byte[4]=IPv4 address, starting with the first octet (e.g., byte[1]=0xC0, byte[2]=0xA8, byte[3]=0x00, byte[4]=0x01 for IP address 192.168.0.1), byte[5-16]=0 byte[17-20]= netmask, byte[21-32]=0, byte[33-36]= router IPv4 address (0 if not configured), starting with the first octet, byte[37-48]=0. For IPv6: byte[1-16]=IPv6 address, starting with the first octet. byte[17-32]= netmask, byte[33-48]= router IPv6 address (0 if not configured), starting with the first octet byte[49-54]= MAC address (starting with the MAC address least significant byte in byte[49] and ending with the most significant byte in byte[54]). |
| STAT_ECU_TYPE_BIT1_TEXT |
string |
Text with meaning of this bit, if bit is set in result STAT_ECU_TYPE. |
| STAT_ECU_TYPE_BIT2_TEXT |
string |
Text with meaning of this bit, if bit is set in result STAT_ECU_TYPE. |
| STAT_ECU_TYPE_BIT3_TEXT |
string |
Text with meaning of this bit, if bit is set in result STAT_ECU_TYPE. |
| STAT_ECU_TYPE_BIT4_TEXT |
string |
Text with meaning of this bit, if bit is set in result STAT_ECU_TYPE. |
| STAT_ECU_TYPE_BIT5_TEXT |
string |
Text with meaning of this bit, if bit is set in result STAT_ECU_TYPE. |
| STAT_ECU_TYPE_BIT6_TEXT |
string |
Text with meaning of this bit, if bit is set in result STAT_ECU_TYPE. |
| STAT_ECU_TYPE_BIT7_TEXT |
string |
Text with meaning of this bit, if bit is set in result STAT_ECU_TYPE. |
| STAT_ECU_TYPE_BIT8_TEXT |
string |
Text with meaning of this bit, if bit is set in result STAT_ECU_TYPE. |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN_ETH_WRITE_PHY_REGISTER
Writes an arbitrary PHY, MAC or switch register. UDS : $31 RoutineControl $01 StartRoutine $104D
Arguments
| Name |
Type |
Comment |
| INPUTDATA |
binary |
1st byte REG_WRITE_PROTECT, uint8: To avoid misuse or an inadvertent write of registers, REG_WRITE_PROTECT must be set to 0xEE in order to execute the job. The job execution shall be aborted if the parameter REG_WRITE_PROTECT is != 0xEE. --------- followed by 1 byte: REG_WRITE_RANGE: Number of registers that shall be written to (enumeration starts at 1). (uint8, 0= no write, 1-255= write 1 to 255 registers ) --------- followed by: REG_ADDR[] - each entry 4byte uint32. Addresses that shall be written to. If the number of provided addresses is not equal to REG_WRITE_RANGE, the job execution shall be aborted. Each address must be converted to a unique PHY, MAC or switch register address. The conversion shall be handled individually by each ECU. The used mapping scheme shall take into account all available PHYs, MACs and switches the ECU is equipped with and that are visible externally, i.e., via an connector. --------- followed by 1 byte: REG_WRITE_RANGE: Number of registers that shall be written to (enumeration starts at 1). (uint8, 0= no write, 1-255= write 1 to 255 registers) --------- followed by: REG_WRITE_LENGTH[] - each entry 1 byte uint8. Entry n in REG_WRITE_LENGTH[] specifies how many bytes shall be written to the register address defined by entry n in REG_ADDR[]. Enumeration shall start at 1. If the number of entries is not equal to REG_WRITE_RANGE, the job execution shall be aborted. --------- followed by 1 byte: REG_WRITE_RANGE: Number of registers that shall be written to (enumeration starts at 1). (uint8, 0= no write, 1-255= write 1 to 255 registers) --------- followed by: REG_WRITE_DATA[] - each entry 8 bytes uint64. Entry n in REG_WRITE_DATA[] provides the data that shall be written to the register address defined by entry n in REG_ADDR[]. The amount of bytes (starting with the least significant byte) that are actually written are defined by entry n in REG_WRITE_LENGTH[]. If the number of entries is not equal to REG_WRITE_RANGE, the job execution shall be aborted. Enumeration shall start at 1. |
Results
| Name |
Type |
Comment |
| STAT_REG_WRITE_OK |
unsigned char |
Shall indicate, whether writing to the PHY registers was successful. (0 = write ok, 1 = write not ok) |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
Tables
Index
JOBRESULT
Dimensions: 76 rows × 2 columns
| SB |
STATUS_TEXT |
| 0x10 |
ERROR_ECU_GENERAL_REJECT |
| 0x11 |
ERROR_ECU_SERVICE_NOT_SUPPORTED |
| 0x12 |
ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED |
| 0x13 |
ERROR_ECU_INCORRECT_MESSAGE_LENGTH_OR_INVALID_FORMAT |
| 0x14 |
ERROR_ECU_RESPONSE_TOO_LONG |
| 0x21 |
ERROR_ECU_BUSY_REPEAT_REQUEST |
| 0x22 |
ERROR_ECU_CONDITIONS_NOT_CORRECT |
| 0x24 |
ERROR_ECU_REQUEST_SEQUENCE_ERROR |
| 0x25 |
ERROR_ECU_NO_RESPONSE_FROM_SUBNET_COMPONENT |
| 0x26 |
ERROR_ECU_FAILURE_PREVENTS_EXECUTION_OF_REQUESTED_ACTION |
| 0x31 |
ERROR_ECU_REQUEST_OUT_OF_RANGE |
| 0x33 |
ERROR_ECU_SECURITY_ACCESS_DENIED |
| 0x35 |
ERROR_ECU_INVALID_KEY |
| 0x36 |
ERROR_ECU_EXCEED_NUMBER_OF_ATTEMPTS |
| 0x37 |
ERROR_ECU_REQUIRED_TIME_DELAY_NOT_EXPIRED |
| 0x70 |
ERROR_ECU_UPLOAD_DOWNLOAD_NOT_ACCEPTED |
| 0x71 |
ERROR_ECU_TRANSFER_DATA_SUSPENDED |
| 0x72 |
ERROR_ECU_GENERAL_PROGRAMMING_FAILURE |
| 0x73 |
ERROR_ECU_WRONG_BLOCK_SEQUENCE_COUNTER |
| 0x78 |
ERROR_ECU_REQUEST_CORRECTLY_RECEIVED__RESPONSE_PENDING |
| 0x7E |
ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED_IN_ACTIVE_SESSION |
| 0x7F |
ERROR_ECU_SERVICE_NOT_SUPPORTED_IN_ACTIVE_SESSION |
| 0x81 |
ERROR_ECU_RPM_TOO_HIGH |
| 0x82 |
ERROR_ECU_RPM_TOO_LOW |
| 0x83 |
ERROR_ECU_ENGINE_IS_RUNNING |
| 0x84 |
ERROR_ECU_ENGINE_IS_NOT_RUNNING |
| 0x85 |
ERROR_ECU_ENGINE_RUN_TIME_TOO_LOW |
| 0x86 |
ERROR_ECU_TEMPERATURE_TOO_HIGH |
| 0x87 |
ERROR_ECU_TEMPERATURE_TOO_LOW |
| 0x88 |
ERROR_ECU_VEHICLE_SPEED_TOO_HIGH |
| 0x89 |
ERROR_ECU_VEHICLE_SPEED_TOO_LOW |
| 0x8A |
ERROR_ECU_THROTTLE_PEDAL_TOO_HIGH |
| 0x8B |
ERROR_ECU_THROTTLE_PEDAL_TOO_LOW |
| 0x8C |
ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_NEUTRAL |
| 0x8D |
ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_GEAR |
| 0x8F |
ERROR_ECU_BRAKE_SWITCH_NOT_CLOSED |
| 0x90 |
ERROR_ECU_SHIFTER_LEVER_NOT_IN_PARK |
| 0x91 |
ERROR_ECU_TORQUE_CONVERTER_CLUTCH_LOCKED |
| 0x92 |
ERROR_ECU_VOLTAGE_TOO_HIGH |
| 0x93 |
ERROR_ECU_VOLTAGE_TOO_LOW |
| ?00? |
OKAY |
| ?01? |
ERROR_ECU_NO_RESPONSE |
| ?02? |
ERROR_ECU_INCORRECT_LEN |
| ?03? |
ERROR_ECU_INCORRECT_RESPONSE_ID |
| ?04? |
ERROR_ECU_TA_RESPONSE_NOT_SA_REQUEST |
| ?05? |
ERROR_ECU_SA_RESPONSE_NOT_TA_REQUEST |
| ?06? |
ERROR_ECU_RESPONSE_INCORRECT_DATA_IDENTIFIER |
| ?07? |
ERROR_ECU_RESPONSE_TOO_MUCH_DATA |
| ?08? |
ERROR_ECU_RESPONSE_TOO_LESS_DATA |
| ?09? |
ERROR_ECU_RESPONSE_VALUE_OUT_OF_RANGE |
| ?0A? |
ERROR_TABLE |
| ?10? |
ERROR_F_CODE |
| ?12? |
ERROR_INTERPRETATION |
| ?13? |
ERROR_F_POS |
| ?14? |
ERROR_ECU_RESPONSE_INCORRECT_IO_CONTROL_PARAMETER |
| ?15? |
ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_CONTROL_TYPE |
| ?16? |
ERROR_ECU_RESPONSE_INCORRECT_SUB_FUNCTION |
| ?17? |
ERROR_ECU_RESPONSE_INCORRECT_DYNAMICALLY_DEFINED_DATA_IDENTIFIER |
| ?18? |
ERROR_ECU_RESPONSE_NO_STRING_END_CHAR |
| ?19? |
ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_IDENTIFIER |
| ?1A? |
ERROR_ECU_RESPONSE_INCORRECT_RESET_TYPE |
| ?1B? |
ERROR_ECU_RESPONSE_INCORRECT_SERIAL_NUMBER_FORMAT |
| ?1C? |
ERROR_ECU_RESPONSE_INCORRECT_DTC_BY_STATUS_MASK |
| ?1D? |
ERROR_ECU_RESPONSE_INCORRECT_DTC_STATUS_AVAILABILITY_MASK |
| ?1E? |
ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_CONTROL_IDENTIFIER |
| ?50? |
ERROR_BYTE1 |
| ?51? |
ERROR_BYTE2 |
| ?52? |
ERROR_BYTE3 |
| ?60? |
ERROR_VERIFY |
| ?61? |
ERROR_ECU_RESPONSE_ZGW |
| ?62? |
ERROR_ECU_RESPONSE_BACKUP |
| ?70? |
ERROR_CALID_CVN_INCORRECT_LEN |
| ?80? |
ERROR_SVK_INCORRECT_LEN |
| ?81? |
ERROR_SVK_INCORRECT_FINGERPRINT |
| ?F0? |
ERROR_ARGUMENT |
| 0xXY |
ERROR_ECU_UNKNOWN_NEGATIVE_RESPONSE |
LIEFERANTEN
Dimensions: 141 rows × 2 columns
| LIEF_NR |
LIEF_TEXT |
| 0x000001 |
Reinshagen / Delphi |
| 0x000002 |
Leopold Kostal GmbH & Co. KG |
| 0x000003 |
Hella Fahrzeugkomponenten GmbH |
| 0x000004 |
Siemens |
| 0x000005 |
Eaton |
| 0x000006 |
UTA |
| 0x000007 |
Helbako GmbH |
| 0x000008 |
Robert Bosch GmbH |
| 0x000009 |
Lear Corporation |
| 0x000010 |
VDO |
| 0x000011 |
Valeo GmbH |
| 0x000012 |
MBB |
| 0x000013 |
Kammerer |
| 0x000014 |
SWF |
| 0x000015 |
Blaupunkt |
| 0x000016 |
Philips |
| 0x000017 |
Alpine Electronics GmbH |
| 0x000018 |
Continental Teves AG & Co. OHG |
| 0x000019 |
Elektromatik Südafrika |
| 0x000020 |
Harman Becker Automotive Systems |
| 0x000021 |
Preh GmbH |
| 0x000022 |
Alps Electric Co. Ltd. |
| 0x000023 |
Motorola |
| 0x000024 |
Temic |
| 0x000025 |
Webasto SE |
| 0x000026 |
MotoMeter |
| 0x000027 |
Delphi Automotive PLC |
| 0x000028 |
DODUCO (Beru) |
| 0x000029 |
DENSO |
| 0x000030 |
NEC |
| 0x000031 |
DASA |
| 0x000032 |
Pioneer Corporation |
| 0x000033 |
Jatco |
| 0x000034 |
FUBA Automotive GmbH & Co. KG |
| 0x000035 |
UK-NSI |
| 0x000036 |
AABG |
| 0x000037 |
Dunlop |
| 0x000038 |
Sachs |
| 0x000039 |
ITT |
| 0x000040 |
FTE (Fahrzeugtechnik Ebern) |
| 0x000041 |
Megamos |
| 0x000042 |
TRW Automotive GmbH |
| 0x000043 |
WABCO Fahrzeugsysteme GmbH |
| 0x000044 |
ISAD Electronic Systems |
| 0x000045 |
HEC Hella Electronics Corporation |
| 0x000046 |
Gemel |
| 0x000047 |
ZF Friedrichshafen AG |
| 0x000048 |
GMPT |
| 0x000049 |
Harman Becker Automotive Systems GmbH |
| 0x000050 |
Remes GmbH |
| 0x000051 |
ZF Lenksysteme GmbH |
| 0x000052 |
Magneti Marelli S.p.A. |
| 0x000053 |
Johnson Controls Inc. |
| 0x000054 |
GETRAG Getriebe- und Zahnradf. Hermann Hagenmeyer GmbH & Co. KG |
| 0x000055 |
Behr-Hella Thermocontrol GmbH |
| 0x000056 |
Siemens VDO Automotive |
| 0x000057 |
Visteon Innovation & Technology GmbH |
| 0x000058 |
Autoliv AB |
| 0x000059 |
Haberl Electronic GmbH & Co. KG |
| 0x000060 |
Magna International Inc. |
| 0x000061 |
Marquardt GmbH |
| 0x000062 |
AB Elektronik GmbH |
| 0x000063 |
SDVO/BORG |
| 0x000064 |
Hirschmann Car Communication GmbH |
| 0x000065 |
hoerbiger-electronics |
| 0x000066 |
Thyssen Krupp Automotive |
| 0x000067 |
Gentex Corporation |
| 0x000068 |
Atena GmbH |
| 0x000069 |
Magna-Donelly |
| 0x000070 |
Koyo Steeting Europe |
| 0x000071 |
NSI Beheer B.V. |
| 0x000072 |
Aisin AW Co. Ltd. |
| 0x000073 |
Schorlock |
| 0x000074 |
Schrader Electronics Ltd. |
| 0x000075 |
Huf-Electronics Bretten GmbH |
| 0x000076 |
CEL |
| 0x000077 |
AUDIO MOBIL Elektronik GmbH |
| 0x000078 |
rd electronic |
| 0x000079 |
iSYS RTS GmbH |
| 0x000080 |
Westfalia-Automotive GmbH |
| 0x000081 |
Tyco Electronics |
| 0x000082 |
Paragon AG |
| 0x000083 |
IEE S.A. |
| 0x000084 |
TEMIC AUTOMOTIVE of NA |
| 0x000085 |
Sonceboz S.A. |
| 0x000086 |
Meta System S.p.A. |
| 0x000087 |
Huf Hülsbeck & Fürst GmbH & Co. KG |
| 0x000088 |
MANN+HUMMEL GmbH |
| 0x000089 |
Brose Fahrzeugteile GmbH & Co. |
| 0x000090 |
Keihin |
| 0x000091 |
Vimercati S.p.a |
| 0x000092 |
CRH |
| 0x000093 |
TPO Display Corp |
| 0x000094 |
Küster Automotive GmbH |
| 0x000095 |
Hitachi Automotive |
| 0x000096 |
Continental AG |
| 0x000097 |
TI-Automotive |
| 0x000098 |
Hydro |
| 0x000099 |
Johnson Controls Inc. |
| 0x00009A |
Takata-Petri |
| 0x00009B |
Mitsubishi Electric B.V. (Melco) |
| 0x00009C |
Autokabel |
| 0x00009D |
GKN Plc |
| 0x00009E |
Zollner Elektronik AG |
| 0x00009F |
peiker acustic GmbH & Co. KG |
| 0x0000A0 |
Bosal-Oris |
| 0x0000A1 |
Cobasys |
| 0x0000A2 |
Automotive Lighting Reutlingen GmbH |
| 0x0000A3 |
CONTI VDO |
| 0x0000A4 |
A.D.C. Automotive Distance Control Systems GmbH |
| 0x0000A5 |
Novero Dabendorf GmbH |
| 0x0000A6 |
LAMES S.p.a. |
| 0x0000A7 |
Magna/Closures |
| 0x0000A8 |
Harbin Wan Yu Technology Co |
| 0x0000A9 |
ThyssenKrupp Presta AG |
| 0x0000AA |
ArvinMeritor |
| 0x0000AB |
Kongsberg Automotive GmbH |
| 0x0000AC |
SMR Automotive Mirrors Stuttgart GmbH |
| 0x0000AD |
So.Ge.Mi. |
| 0x0000AE |
MTA S.p.A. |
| 0x0000AF |
Alfmeier Präzision AG |
| 0x0000B0 |
Eltek Deutechland GmbH |
| 0x0000B1 |
OMRON Automotive Electronics Europe GmbH |
| 0x0000B2 |
ASK Industries GmbH |
| 0x0000B3 |
CML Innovative Technologies GmbH & Co. KG |
| 0x0000B4 |
APAG Elektronik AG |
| 0x0000B5 |
Nexteer Automotive |
| 0x0000B6 |
Hans Widmaier Fernmelde- und Feinwerktechnik |
| 0x0000B7 |
Robert Bosch Battery Systems GmbH |
| 0x0000B8 |
Kyocera Display Europe GmbH |
| 0x0000B9 |
Magna Powertrain AG & Co. KG |
| 0x0000BA |
BorgWarner Beru Systems GmbH |
| 0x0000BB |
BMW AG |
| 0x0000BC |
Benteler Duncan Plant |
| 0x0000BD |
U-Shin Deutschland Zugangssysteme GmbH |
| 0x0000BE |
Schaeffler Technologies AG & Co. KG |
| 0x0000BF |
JTEKT Corporation |
| 0x0000C0 |
VLF |
| 0x0000C1 |
Flextronics |
| 0x0000C2 |
LG Chem |
| 0xFFFFFF |
unbekannter Hersteller |
FARTTEXTE
Dimensions: 35 rows × 2 columns
| ARTNR |
ARTTEXT |
| 0x00 |
keine Fehlerart verfügbar |
| 0x04 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x05 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x08 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x09 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x0C |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x0D |
Fehler momentan vorhanden und bereits gespeichert |
| 0x20 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x21 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x24 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x25 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x28 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x29 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x2C |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x2D |
Fehler momentan vorhanden und bereits gespeichert |
| 0x40 |
unbekannte Fehlerart |
| 0x44 |
Fehler gespeichert |
| 0x45 |
Fehler gespeichert |
| 0x48 |
Fehler gespeichert |
| 0x49 |
Fehler gespeichert |
| 0x4C |
Fehler gespeichert |
| 0x4D |
Fehler gespeichert |
| 0x60 |
Fehler gespeichert |
| 0x61 |
Fehler gespeichert |
| 0x64 |
Fehler gespeichert |
| 0x65 |
Fehler gespeichert |
| 0x68 |
Fehler gespeichert |
| 0x69 |
Fehler gespeichert |
| 0x6C |
Fehler gespeichert |
| 0x6D |
Fehler gespeichert |
| 0x10 |
Testbedingungen erfüllt |
| 0x11 |
Testbedingungen noch nicht erfüllt |
| 0x80 |
Fehler würde kein Aufleuchten einer Warnlampe verursachen |
| 0x81 |
Fehler würde das Aufleuchten einer Warnlampe verursachen |
| 0xFF |
unbekannte Fehlerart |
DIGITALARGUMENT
Dimensions: 17 rows × 2 columns
| TEXT |
WERT |
| ein |
1 |
| aus |
0 |
| ja |
1 |
| nein |
0 |
| auf |
1 |
| ab |
0 |
| an |
1 |
| yes |
1 |
| no |
0 |
| on |
1 |
| off |
0 |
| up |
1 |
| down |
0 |
| true |
1 |
| false |
0 |
| 1 |
1 |
| 0 |
0 |
PROZESSKLASSEN
Dimensions: 26 rows × 3 columns
| WERT |
PROZESSKLASSE |
BEZEICHNUNG |
| 0x00 |
- |
ungueltig |
| 0x01 |
HWEL |
Hardware (Elektronik) |
| 0x02 |
HWAP |
Hardwareauspraegung |
| 0x03 |
HWFR |
Hardwarefarbe |
| 0x05 |
CAFD |
Codierdaten |
| 0x06 |
BTLD |
Bootloader |
| 0x08 |
SWFL |
Software ECU Speicherimage |
| 0x09 |
SWFF |
Flash File Software |
| 0x0A |
SWPF |
Pruefsoftware |
| 0x0B |
ONPS |
Onboard Programmiersystem |
| 0x0F |
FAFP |
FA2FP |
| 0x1A |
TLRT |
Temporaere Loeschroutine |
| 0x1B |
TPRG |
Temporaere Programmierroutine |
| 0x07 |
FLSL |
Flashloader Slave |
| 0x0C |
IBAD |
Interaktive Betriebsanleitung Daten |
| 0x10 |
FCFA |
Freischaltcode Fahrzeug-Auftrag |
| 0x1C |
BLUP |
Bootloader-Update Applikation |
| 0x1D |
FLUP |
Flashloader-Update Applikation |
| 0xC0 |
SWUP |
Software-Update Package |
| 0xC1 |
SWIP |
Index Software-Update Package |
| 0xA0 |
ENTD |
Entertainment Daten |
| 0xA1 |
NAVD |
Navigation Daten |
| 0xA2 |
FCFN |
Freischaltcode Funktion |
| 0x04 |
GWTB |
Gateway-Tabelle |
| 0x0D |
SWFK |
BEGU: Detaillierung auf SWE-Ebene |
| 0xFF |
- |
ungueltig |
SVK_ID
Dimensions: 65 rows × 2 columns
| WERT |
BEZEICHNUNG |
| 0x01 |
SVK_AKTUELL |
| 0x02 |
SVK_SUPPLIER |
| 0x03 |
SVK_WERK |
| 0x04 |
SVK_BACKUP_01 |
| 0x05 |
SVK_BACKUP_02 |
| 0x06 |
SVK_BACKUP_03 |
| 0x07 |
SVK_BACKUP_04 |
| 0x08 |
SVK_BACKUP_05 |
| 0x09 |
SVK_BACKUP_06 |
| 0x0A |
SVK_BACKUP_07 |
| 0x0B |
SVK_BACKUP_08 |
| 0x0C |
SVK_BACKUP_09 |
| 0x0D |
SVK_BACKUP_10 |
| 0x0E |
SVK_BACKUP_11 |
| 0x0F |
SVK_BACKUP_12 |
| 0x10 |
SVK_BACKUP_13 |
| 0x11 |
SVK_BACKUP_14 |
| 0x12 |
SVK_BACKUP_15 |
| 0x13 |
SVK_BACKUP_16 |
| 0x14 |
SVK_BACKUP_17 |
| 0x15 |
SVK_BACKUP_18 |
| 0x16 |
SVK_BACKUP_19 |
| 0x17 |
SVK_BACKUP_20 |
| 0x18 |
SVK_BACKUP_21 |
| 0x19 |
SVK_BACKUP_22 |
| 0x1A |
SVK_BACKUP_23 |
| 0x1B |
SVK_BACKUP_24 |
| 0x1C |
SVK_BACKUP_25 |
| 0x1D |
SVK_BACKUP_26 |
| 0x1E |
SVK_BACKUP_27 |
| 0x1F |
SVK_BACKUP_28 |
| 0x20 |
SVK_BACKUP_29 |
| 0x21 |
SVK_BACKUP_30 |
| 0x22 |
SVK_BACKUP_31 |
| 0x23 |
SVK_BACKUP_32 |
| 0x24 |
SVK_BACKUP_33 |
| 0x25 |
SVK_BACKUP_34 |
| 0x26 |
SVK_BACKUP_35 |
| 0x27 |
SVK_BACKUP_36 |
| 0x28 |
SVK_BACKUP_37 |
| 0x29 |
SVK_BACKUP_38 |
| 0x2A |
SVK_BACKUP_39 |
| 0x2B |
SVK_BACKUP_40 |
| 0x2C |
SVK_BACKUP_41 |
| 0x2D |
SVK_BACKUP_42 |
| 0x2E |
SVK_BACKUP_43 |
| 0x2F |
SVK_BACKUP_44 |
| 0x30 |
SVK_BACKUP_45 |
| 0x31 |
SVK_BACKUP_46 |
| 0x32 |
SVK_BACKUP_47 |
| 0x33 |
SVK_BACKUP_48 |
| 0x34 |
SVK_BACKUP_49 |
| 0x35 |
SVK_BACKUP_50 |
| 0x36 |
SVK_BACKUP_51 |
| 0x37 |
SVK_BACKUP_52 |
| 0x38 |
SVK_BACKUP_53 |
| 0x39 |
SVK_BACKUP_54 |
| 0x3A |
SVK_BACKUP_55 |
| 0x3B |
SVK_BACKUP_56 |
| 0x3C |
SVK_BACKUP_57 |
| 0x3D |
SVK_BACKUP_58 |
| 0x3E |
SVK_BACKUP_59 |
| 0x3F |
SVK_BACKUP_60 |
| 0x40 |
SVK_BACKUP_61 |
| 0xXY |
ERROR_UNKNOWN |
DTCEXTENDEDDATARECORDNUMBER
Dimensions: 5 rows × 3 columns
| WERT |
TEXT |
ANZ_BYTE |
| 0x00 |
ISO_RESERVED |
0 |
| 0x01 |
CONDITION_BYTE |
1 |
| 0x02 |
HFK |
1 |
| 0x03 |
HLZ |
1 |
| 0xFF |
RECORD_UNKNOWN |
0 |
DTCSNAPSHOTIDENTIFIER
Dimensions: 7 rows × 9 columns
| UWNR |
UWTEXT |
UW_EINH |
L/H |
UWTYP |
NAME |
MUL |
DIV |
ADD |
| 0x1700 |
KM_STAND |
0-n |
- |
0xFFFFFF |
- |
1 |
1 |
0.000000 |
| 0x1701 |
ABS_ZEIT |
0-n |
- |
0xFFFFFFFF |
- |
1 |
1 |
0.000000 |
| 0x1702 |
SAE_CODE |
0-n |
- |
0xFFFFFF |
- |
1 |
1 |
0.000000 |
| 0x1731 |
Fehlerklasse_DTC |
- |
- |
u char |
- |
1 |
1 |
0.000000 |
| 0x1750 |
PWF_Basinetz |
0-n |
- |
0xFF |
- |
1 |
1 |
0.000000 |
| 0x1751 |
PWF_Teilnetz |
0-n |
- |
0xFFFFFF |
- |
1 |
1 |
0.000000 |
| 0xFFFF |
IDENTIFIER_UNKNOWN |
- |
- |
0xFFFFFF |
- |
1 |
1 |
0.000000 |
FEHLERKLASSE
Dimensions: 5 rows × 2 columns
| NR |
TEXT |
| 0x00 |
Keine Fehlerklasse verfuegbar |
| 0x01 |
Ueberpruefung bei naechstem Werkstattbesuch |
| 0x02 |
Ueberpruefung bei naechstem Halt |
| 0x04 |
Ueberpruefung sofort erforderlich ! |
| 0xFF |
unbekannte Fehlerklasse |
DIAGMODE
Dimensions: 12 rows × 3 columns
| NR |
MODE |
MODE_TEXT |
| 0x00 |
UNGUELTIG |
DefaultMode |
| 0x01 |
DEFAULT |
DefaultMode |
| 0x02 |
ECUPM |
ECUProgrammingMode |
| 0x03 |
ECUEXTDIAG |
ECUExtendedDiagnosticSession |
| 0x04 |
ECUSSDS |
ECUSafetySystemDiagnosticSession |
| 0x40 |
ECUEOL |
ECUEndOfLineSession |
| 0x41 |
ECUCODE |
ECUCodingSession |
| 0x42 |
ECUSWT |
ECUSwtSession |
| 0x43 |
ECUHDD |
ECUHDDDownloadSession |
| 0x4F |
ECUDEVELOP |
ECUDevelopmentSession |
| 0x5F |
ECUGDM |
ECUGarageDiagnoseMode |
| 0xXY |
-- |
unbekannter Diagnose-Mode |
IARTTEXTE
Dimensions: 35 rows × 2 columns
| ARTNR |
ARTTEXT |
| 0x00 |
keine Fehlerart verfügbar |
| 0x04 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x05 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x08 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x09 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x0C |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x0D |
Fehler momentan vorhanden und bereits gespeichert |
| 0x20 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x21 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x24 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x25 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x28 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x29 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x2C |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x2D |
Fehler momentan vorhanden und bereits gespeichert |
| 0x40 |
unbekannte Fehlerart |
| 0x44 |
Fehler gespeichert |
| 0x45 |
Fehler gespeichert |
| 0x48 |
Fehler gespeichert |
| 0x49 |
Fehler gespeichert |
| 0x4C |
Fehler gespeichert |
| 0x4D |
Fehler gespeichert |
| 0x60 |
Fehler gespeichert |
| 0x61 |
Fehler gespeichert |
| 0x64 |
Fehler gespeichert |
| 0x65 |
Fehler gespeichert |
| 0x68 |
Fehler gespeichert |
| 0x69 |
Fehler gespeichert |
| 0x6C |
Fehler gespeichert |
| 0x6D |
Fehler gespeichert |
| 0x10 |
Testbedingungen erfüllt |
| 0x11 |
Testbedingungen noch nicht erfüllt |
| 0x80 |
Fehler würde kein Aufleuchten einer Warnlampe verursachen |
| 0x81 |
Fehler würde das Aufleuchten einer Warnlampe verursachen |
| 0xFF |
unbekannte Fehlerart |
UDS_TAB_ROE_AKTIV
Dimensions: 3 rows × 2 columns
| NR |
TEXT |
| 0x00 |
Aktive Fehlermeldung deaktiviert |
| 0x01 |
Aktive Fehlermeldung aktiviert |
| 0xFF |
Status der aktiven Fehlermeldung nicht feststellbar |
ARG_0X1046_R
Dimensions: 1 rows × 14 columns
| ARG |
STR |
STPR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| PORT_INDEX |
+ |
- |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Portindex des zur diagnostizierenden Ports/PHYs (beginnend bei Port 0). Wertebereich: Port 0 - Port n-1 (bei insgesamt n Ports) |
ARG_0X1047_R
Dimensions: 1 rows × 14 columns
| ARG |
STR |
STPR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| PORT_INDEX |
+ |
- |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Portindex Wertebereich: Port 0 - Port n-1 (bei insgesamt n Ports) |
ARG_0X1049_R
Dimensions: 1 rows × 14 columns
| ARG |
STR |
STPR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| PORT_INDEX |
+ |
- |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Index des Ports, für den die Daten ausgelesen werden sollen. Wertebereich: Port 0 - Port n-1 (bei insgesamt n Ports) Wertebereich: Port 0 - Port n-1 (bei insgesamt n Ports) |
ARG_0X104C_R
Dimensions: 3 rows × 14 columns
| ARG |
STR |
STPR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| PORT_INDEX |
+ |
- |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Index des Ports, für den der Testmodus geschaltet werden soll. |
| TEST_DURATION |
+ |
- |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Zeit, für die der Testmodus geschaltet werden soll. Der Wert wird im SG mit 10 multipliziert, so dass die Testdauer von 0s bis 2550s variiert werden kann. |
| TEST_MODE_ID |
+ |
- |
0-n |
high |
unsigned char |
- |
ETH_TEST_MODE_TAB |
- |
- |
- |
- |
- |
ID des Testmodus, in den der PHY geschaltet werden soll |
BF_ETH_IP_CONFIGURATION_ECU_TYPE
Dimensions: 8 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| BIT_0 |
0/1 |
high |
unsigned char |
0x01 |
- |
- |
- |
- |
Wenn 1, dann besitzt das Steuergerät keinen Switch. |
| BIT_1 |
0/1 |
high |
unsigned char |
0x02 |
- |
- |
- |
- |
Wenn 1, dann besitzt das Steuergerät einen Switch. Dieser ist (auch) mit mindestens einem regulären externen Port verbunden. |
| BIT_2 |
0/1 |
high |
unsigned char |
0x04 |
- |
- |
- |
- |
Wenn 1, dann besitzt das Steuergerät einen Port, der (auch) mit mindestens einem externen Special Function Port (z.B. APIX) verbunden ist. |
| BIT_3 |
0/1 |
high |
unsigned char |
0x08 |
- |
- |
- |
- |
Wenn 1, dann besitzzt das Steuergerät einen Switch, der (auch) intern genutzt wird. |
| BIT_4 |
0/1 |
high |
unsigned char |
0x10 |
- |
- |
- |
- |
Wenn 1, dann hat das Steuergerät mindestesn einen regulären externen Port. |
| BIT_5 |
0/1 |
high |
unsigned char |
0x20 |
- |
- |
- |
- |
Wenn 1, dann besitzt das Steuergerät mindestens einen Special Function Port (z.B. APIX). |
| BIT_6 |
0/1 |
high |
unsigned char |
0x40 |
- |
- |
- |
- |
reserviert |
| BIT_7 |
0/1 |
high |
unsigned char |
0x80 |
- |
- |
- |
- |
reserviert |
BF_ETH_PORT_CONFIGURATION
Dimensions: 16 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_PORT_00 |
0-n |
high |
unsigned char |
0x0001 |
ETH_PORT_CONFIGURATION |
- |
- |
- |
Portstatus Port 00 |
| STAT_PORT_01 |
0-n |
high |
unsigned char |
0x0002 |
ETH_PORT_CONFIGURATION |
- |
- |
- |
Portstatus Port 01 |
| STAT_PORT_02 |
0-n |
high |
unsigned char |
0x0004 |
ETH_PORT_CONFIGURATION |
- |
- |
- |
Portstatus Port 02 |
| STAT_PORT_03 |
0-n |
high |
unsigned char |
0x0008 |
ETH_PORT_CONFIGURATION |
- |
- |
- |
Portstatus Port 03 |
| STAT_PORT_04 |
0-n |
high |
unsigned char |
0x0010 |
ETH_PORT_CONFIGURATION |
- |
- |
- |
Portstatus Port 04 |
| STAT_PORT_05 |
0-n |
high |
unsigned char |
0x0020 |
ETH_PORT_CONFIGURATION |
- |
- |
- |
Portstatus Port 05 |
| STAT_PORT_06 |
0-n |
high |
unsigned char |
0x0040 |
ETH_PORT_CONFIGURATION |
- |
- |
- |
Portstatus Port 06 |
| STAT_PORT_07 |
0-n |
high |
unsigned char |
0x0080 |
ETH_PORT_CONFIGURATION |
- |
- |
- |
Portstatus Port 07 |
| STAT_PORT_08 |
0-n |
high |
unsigned char |
0x0100 |
ETH_PORT_CONFIGURATION |
- |
- |
- |
Portstatus Port 08 |
| STAT_PORT_09 |
0-n |
high |
unsigned char |
0x0200 |
ETH_PORT_CONFIGURATION |
- |
- |
- |
Portstatus Port 09 |
| STAT_PORT_10 |
0-n |
high |
unsigned char |
0x0400 |
ETH_PORT_CONFIGURATION |
- |
- |
- |
Portstatus Port 10 |
| STAT_PORT_11 |
0-n |
high |
unsigned char |
0x0800 |
ETH_PORT_CONFIGURATION |
- |
- |
- |
Portstatus Port 11 |
| STAT_PORT_12 |
0-n |
high |
unsigned char |
0x1000 |
ETH_PORT_CONFIGURATION |
- |
- |
- |
Portstatus Port 12 |
| STAT_PORT_13 |
0-n |
high |
unsigned char |
0x2000 |
ETH_PORT_CONFIGURATION |
- |
- |
- |
Portstatus Port 13 |
| STAT_PORT_14 |
0-n |
high |
unsigned char |
0x4000 |
ETH_PORT_CONFIGURATION |
- |
- |
- |
Portstatus Port 14 |
| STAT_PORT_15 |
0-n |
high |
unsigned char |
0x8000 |
ETH_PORT_CONFIGURATION |
- |
- |
- |
Portstatus Port 15 |
BF_PHY_LINK_STATE_BTFLD
Dimensions: 16 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_PHY_LINK_STATE_PORT_00 |
0-n |
high |
unsigned int |
0x0001 |
PHY_LINK_STATE_TAB |
- |
- |
- |
Linkstatus für Port 0 |
| STAT_PHY_LINK_STATE_PORT_01 |
0-n |
high |
unsigned int |
0x0002 |
PHY_LINK_STATE_TAB |
- |
- |
- |
Linkstatus für Port 1 |
| STAT_PHY_LINK_STATE_PORT_02 |
0-n |
high |
unsigned int |
0x0004 |
PHY_LINK_STATE_TAB |
- |
- |
- |
Linkstatus für Port 2 |
| STAT_PHY_LINK_STATE_PORT_03 |
0-n |
high |
unsigned int |
0x0008 |
PHY_LINK_STATE_TAB |
- |
- |
- |
Linkstatus für Port 3 |
| STAT_PHY_LINK_STATE_PORT_04 |
0-n |
high |
unsigned int |
0x0010 |
PHY_LINK_STATE_TAB |
- |
- |
- |
Linkstatus für Port 4 |
| STAT_PHY_LINK_STATE_PORT_05 |
0-n |
high |
unsigned int |
0x0020 |
PHY_LINK_STATE_TAB |
- |
- |
- |
Linkstatus für Port 5 |
| STAT_PHY_LINK_STATE_PORT_06 |
0-n |
high |
unsigned int |
0x0040 |
PHY_LINK_STATE_TAB |
- |
- |
- |
Linkstatus für Port 6 |
| STAT_PHY_LINK_STATE_PORT_07 |
0-n |
high |
unsigned int |
0x0080 |
PHY_LINK_STATE_TAB |
- |
- |
- |
Linkstatus für Port 7 |
| STAT_PHY_LINK_STATE_PORT_08 |
0-n |
high |
unsigned int |
0x0100 |
PHY_LINK_STATE_TAB |
- |
- |
- |
Linkstatus für Port 8 |
| STAT_PHY_LINK_STATE_PORT_09 |
0-n |
high |
unsigned int |
0x0200 |
PHY_LINK_STATE_TAB |
- |
- |
- |
Linkstatus für Port 9 |
| STAT_PHY_LINK_STATE_PORT_10 |
0-n |
high |
unsigned int |
0x0400 |
PHY_LINK_STATE_TAB |
- |
- |
- |
Linkstatus für Port 10 |
| STAT_PHY_LINK_STATE_PORT_11 |
0-n |
high |
unsigned int |
0x0800 |
PHY_LINK_STATE_TAB |
- |
- |
- |
Linkstatus für Port 11 |
| STAT_PHY_LINK_STATE_PORT_12 |
0-n |
high |
unsigned int |
0x1000 |
PHY_LINK_STATE_TAB |
- |
- |
- |
Linkstatus für Port 12 |
| STAT_PHY_LINK_STATE_PORT_13 |
0-n |
high |
unsigned int |
0x2000 |
PHY_LINK_STATE_TAB |
- |
- |
- |
Linkstatus für Port 13 |
| STAT_PHY_LINK_STATE_PORT_14 |
0-n |
high |
unsigned int |
0x4000 |
PHY_LINK_STATE_TAB |
- |
- |
- |
Linkstatus für Port 14 |
| STAT_PHY_LINK_STATE_PORT_15 |
0-n |
high |
unsigned int |
0x8000 |
PHY_LINK_STATE_TAB |
- |
- |
- |
Linkstatus für Port 15 |
BETRIEBSMODE
Dimensions: 6 rows × 3 columns
| WERT |
TEXT |
BEDEUTUNG |
| 0x00 |
Allgemeiner Fertigungs- und Energiesparmode |
Hier deaktivierte Funktionen gemäß FeTra-Liste festhalten |
| 0x01 |
Spezieller Energiesparmode |
- |
| 0x02 |
ECOS-Mode |
- |
| 0x03 |
MOST-Mode |
- |
| 0x04 |
Rollenmode |
- |
| 0xFF |
ungültiger Betriebsmode |
ungültig |
CABLE_DIAG_STATE_TAB
Dimensions: 8 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
Leitungspaar OK - kein Fehler gefunden |
| 0x01 |
Kurzschluss zwischen Leitungspaar |
| 0x02 |
Leitungspaar unterbrochen |
| 0x03 |
Kurzschluss nach Masse |
| 0x04 |
Kurzschluss nach 12V |
| 0x05 |
Kabeldiagnose nicht erfolgreich abgeschlossen |
| 0x10 |
Diagnose läuft bereits (bei aufeinanderfolgenden Jobaufrufen |
| 0xFF |
Diagnose konnte nicht gestartet werden, PHY unterstützt Kabeldiagnose nicht oder Port nicht vorhanden |
ETH_LEARN_PORT_CONFIGURATION
Dimensions: 2 rows × 2 columns
| WERT |
TEXT |
| 0x0 |
Lernen erfolgreich |
| 0x1 |
Lernen nicht erfolgreich oder noch nicht gelernt |
ETH_LOOPBACK_MODE_TAB
Dimensions: 2 rows × 2 columns
| WERT |
TEXT |
| 1 |
internal Loopback-Mode |
| 2 |
external Loopback-Mode |
ETH_PHY_LOOPBACK_TEST
Dimensions: 4 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
Test erfolgreich durchgelaufen und TX- und RX-Zähler wurden wie erwartet inkrementiert |
| 0x01 |
Test konnte nicht gestartet werden, da nach Aktivierung des Loopback-modes kein Link aufgebaut werden konnte |
| 0x02 |
Test nicht erfolgreich, TX- und RX-Zähler wurden durch Versendung des Testframes nicht inkrementiert |
| 0xFF |
Test läuft bereits |
ETH_PHY_TEST_MODE_STATE
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
PHY wird in den Testmodus geschaltet |
| 0x01 |
PHY kann nicht in den Testmodus geschaltet werden |
| 0x02 |
Gewünschter Testmodus für Port/Switch nicht verfügbar |
ETH_PORT_CONFIGURATION
Dimensions: 2 rows × 2 columns
| WERT |
TEXT |
| 0x0 |
link-down |
| 0x1 |
link-up |
ETH_TEST_MODE_TAB
Dimensions: 5 rows × 2 columns
| WERT |
TEXT |
| 0x01 |
Transmit droop test Mode |
| 0x02 |
Transmit Jitter test in MASTER Mode |
| 0x03 |
Transmit Jitter test in SLAVE Mode |
| 0x04 |
Transmit Distortion test |
| 0x05 |
Normal Operation at full power necessary for the PSD mask Test |
FDETAILSTRUKTUR
Dimensions: 6 rows × 2 columns
| NAME |
TYP |
| F_UWB_ERW |
ja |
| SAE_CODE |
nein |
| F_HLZ |
nein |
| F_SEVERITY |
nein |
| F_UWB_SATZ |
2 |
| F_HLZ_VIEW |
nein |
FORTTEXTE
Dimensions: 10 rows × 3 columns
| ORT |
ORTTEXT |
EREIGNIS_DTC |
| 0x021100 |
Energiesparmode aktiv |
0 |
| 0x02FF11 |
Dummy-Fehlerspeichereintrag im Komponentenfehlerbereich nur für Testzwecke |
1 |
| 0x807200 |
Fehler im Basis-IO-System |
0 |
| 0x807201 |
Unterspannung erkannt |
1 |
| 0xCD4600 |
Ethernet: Kommunikationsfehler (Link-Abbruch) |
1 |
| 0xCD4602 |
Ethernet: Link-Qualität niedrig |
1 |
| 0xCD4603 |
Ethernet: Kommunikationsfehler (Link-Abbruch) durch Steuergeräte-Reset |
1 |
| 0xCD4604 |
Ethernet: Unerwarteter Link aufgebaut |
1 |
| 0xCD4BFF |
Dummy-Fehlerspeichereintrag im Netzwerkfehlerbereich nur für Testzwecke |
1 |
| 0xFFFFFF |
unbekannter Fehlerort |
0 |
FUMWELTTEXTE
Dimensions: 59 rows × 9 columns
| UWNR |
UWTEXT |
UW_EINH |
L/H |
UWTYP |
NAME |
MUL |
DIV |
ADD |
| 0x0001 |
DETECTED_UNEXPECTED_LINK_STATUS_PORT_00 |
0-n |
High |
0x0001 |
UNEXPECTED_LINK_UP_STATUS_TAB |
- |
- |
- |
| 0x0002 |
DETECTED_UNEXPECTED_LINK_STATUS_PORT_01 |
0-n |
High |
0x0002 |
UNEXPECTED_LINK_UP_STATUS_TAB |
- |
- |
- |
| 0x0003 |
DETECTED_UNEXPECTED_LINK_STATUS_PORT_02 |
0-n |
High |
0x0004 |
UNEXPECTED_LINK_UP_STATUS_TAB |
- |
- |
- |
| 0x0004 |
DETECTED_UNEXPECTED_LINK_STATUS_PORT_03 |
0-n |
High |
0x0008 |
UNEXPECTED_LINK_UP_STATUS_TAB |
- |
- |
- |
| 0x0005 |
DETECTED_UNEXPECTED_LINK_STATUS_PORT_04 |
0-n |
High |
0x0010 |
UNEXPECTED_LINK_UP_STATUS_TAB |
- |
- |
- |
| 0x0006 |
DETECTED_UNEXPECTED_LINK_STATUS_PORT_05 |
0-n |
High |
0x0020 |
UNEXPECTED_LINK_UP_STATUS_TAB |
- |
- |
- |
| 0x0007 |
DETECTED_UNEXPECTED_LINK_STATUS_PORT_06 |
0-n |
High |
0x0040 |
UNEXPECTED_LINK_UP_STATUS_TAB |
- |
- |
- |
| 0x0008 |
DETECTED_UNEXPECTED_LINK_STATUS_PORT_07 |
0-n |
High |
0x0080 |
UNEXPECTED_LINK_UP_STATUS_TAB |
- |
- |
- |
| 0x0009 |
DETECTED_UNEXPECTED_LINK_STATUS_PORT_08 |
0-n |
High |
0x0100 |
UNEXPECTED_LINK_UP_STATUS_TAB |
- |
- |
- |
| 0x000A |
DETECTED_UNEXPECTED_LINK_STATUS_PORT_09 |
0-n |
High |
0x0200 |
UNEXPECTED_LINK_UP_STATUS_TAB |
- |
- |
- |
| 0x000B |
DETECTED_UNEXPECTED_LINK_STATUS_PORT_10 |
0-n |
High |
0x0400 |
UNEXPECTED_LINK_UP_STATUS_TAB |
- |
- |
- |
| 0x000C |
DETECTED_UNEXPECTED_LINK_STATUS_PORT_11 |
0-n |
High |
0x0800 |
UNEXPECTED_LINK_UP_STATUS_TAB |
- |
- |
- |
| 0x000D |
DETECTED_UNEXPECTED_LINK_STATUS_PORT_12 |
0-n |
High |
0x1000 |
UNEXPECTED_LINK_UP_STATUS_TAB |
- |
- |
- |
| 0x000E |
DETECTED_UNEXPECTED_LINK_STATUS_PORT_13 |
0-n |
High |
0x2000 |
UNEXPECTED_LINK_UP_STATUS_TAB |
- |
- |
- |
| 0x000F |
DETECTED_UNEXPECTED_LINK_STATUS_PORT_14 |
0-n |
High |
0x4000 |
UNEXPECTED_LINK_UP_STATUS_TAB |
- |
- |
- |
| 0x0010 |
DETECTED_UNEXPECTED_LINK_STATUS_PORT_15 |
0-n |
High |
0x8000 |
UNEXPECTED_LINK_UP_STATUS_TAB |
- |
- |
- |
| 0x0011 |
LINK_RESET_STATUS_00 |
0-n |
High |
0x0001 |
LINK_RESET_STATUS_TAB |
- |
- |
- |
| 0x0012 |
LINK_RESET_STATUS_01 |
0-n |
High |
0x0002 |
LINK_RESET_STATUS_TAB |
- |
- |
- |
| 0x0013 |
LINK_RESET_STATUS_02 |
0-n |
High |
0x0004 |
LINK_RESET_STATUS_TAB |
- |
- |
- |
| 0x0014 |
LINK_RESET_STATUS_03 |
0-n |
High |
0x0008 |
LINK_RESET_STATUS_TAB |
- |
- |
- |
| 0x0015 |
LINK_RESET_STATUS_04 |
0-n |
High |
0x0010 |
LINK_RESET_STATUS_TAB |
- |
- |
- |
| 0x0016 |
LINK_RESET_STATUS_05 |
0-n |
High |
0x0020 |
LINK_RESET_STATUS_TAB |
- |
- |
- |
| 0x0017 |
LINK_RESET_STATUS_06 |
0-n |
High |
0x0040 |
LINK_RESET_STATUS_TAB |
- |
- |
- |
| 0x0018 |
LINK_RESET_STATUS_07 |
0-n |
High |
0x0080 |
LINK_RESET_STATUS_TAB |
- |
- |
- |
| 0x0019 |
LINK_RESET_STATUS_08 |
0-n |
High |
0x0100 |
LINK_RESET_STATUS_TAB |
- |
- |
- |
| 0x001A |
LINK_RESET_STATUS_09 |
0-n |
High |
0x0200 |
LINK_RESET_STATUS_TAB |
- |
- |
- |
| 0x001B |
LINK_RESET_STATUS_10 |
0-n |
High |
0x0400 |
LINK_RESET_STATUS_TAB |
- |
- |
- |
| 0x001C |
LINK_RESET_STATUS_11 |
0-n |
High |
0x0800 |
LINK_RESET_STATUS_TAB |
- |
- |
- |
| 0x001D |
LINK_RESET_STATUS_12 |
0-n |
High |
0x1000 |
LINK_RESET_STATUS_TAB |
- |
- |
- |
| 0x001E |
LINK_RESET_STATUS_13 |
0-n |
High |
0x2000 |
LINK_RESET_STATUS_TAB |
- |
- |
- |
| 0x001F |
LINK_RESET_STATUS_14 |
0-n |
High |
0x4000 |
LINK_RESET_STATUS_TAB |
- |
- |
- |
| 0x0020 |
LINK_RESET_STATUS_15 |
0-n |
High |
0x8000 |
LINK_RESET_STATUS_TAB |
- |
- |
- |
| 0x0021 |
PORT_LINK_OFF_STATUS_00 |
0-n |
High |
0x0001 |
PORT_LINK_STATUS_TAB |
- |
- |
- |
| 0x0022 |
PORT_LINK_OFF_STATUS_01 |
0-n |
High |
0x0002 |
PORT_LINK_STATUS_TAB |
- |
- |
- |
| 0x0023 |
PORT_LINK_OFF_STATUS_02 |
0-n |
High |
0x0004 |
PORT_LINK_STATUS_TAB |
- |
- |
- |
| 0x0024 |
PORT_LINK_OFF_STATUS_03 |
0-n |
High |
0x0008 |
PORT_LINK_STATUS_TAB |
- |
- |
- |
| 0x0025 |
PORT_LINK_OFF_STATUS_04 |
0-n |
High |
0x0010 |
PORT_LINK_STATUS_TAB |
- |
- |
- |
| 0x0026 |
PORT_LINK_OFF_STATUS_05 |
0-n |
High |
0x0020 |
PORT_LINK_STATUS_TAB |
- |
- |
- |
| 0x0027 |
PORT_LINK_OFF_STATUS_06 |
0-n |
High |
0x0040 |
PORT_LINK_STATUS_TAB |
- |
- |
- |
| 0x0028 |
PORT_LINK_OFF_STATUS_07 |
0-n |
High |
0x0080 |
PORT_LINK_STATUS_TAB |
- |
- |
- |
| 0x0029 |
PORT_LINK_OFF_STATUS_08 |
0-n |
High |
0x0100 |
PORT_LINK_STATUS_TAB |
- |
- |
- |
| 0x002A |
PORT_LINK_OFF_STATUS_09 |
0-n |
High |
0x0200 |
PORT_LINK_STATUS_TAB |
- |
- |
- |
| 0x002B |
PORT_LINK_OFF_STATUS_10 |
0-n |
High |
0x0400 |
PORT_LINK_STATUS_TAB |
- |
- |
- |
| 0x002C |
PORT_LINK_OFF_STATUS_11 |
0-n |
High |
0x0800 |
PORT_LINK_STATUS_TAB |
- |
- |
- |
| 0x002D |
PORT_LINK_OFF_STATUS_12 |
0-n |
High |
0x1000 |
PORT_LINK_STATUS_TAB |
- |
- |
- |
| 0x002E |
PORT_LINK_OFF_STATUS_13 |
0-n |
High |
0x2000 |
PORT_LINK_STATUS_TAB |
- |
- |
- |
| 0x002F |
PORT_LINK_OFF_STATUS_14 |
0-n |
High |
0x4000 |
PORT_LINK_STATUS_TAB |
- |
- |
- |
| 0x0030 |
PORT_LINK_OFF_STATUS_15 |
0-n |
High |
0x8000 |
PORT_LINK_STATUS_TAB |
- |
- |
- |
| 0x0031 |
Hardware Version |
0/1 |
High |
0x01 |
- |
- |
- |
- |
| 0x0032 |
Portanzahl |
0/1 |
High |
0x02 |
- |
- |
- |
- |
| 0x0033 |
SPI Kommunikation |
0/1 |
High |
0x04 |
- |
- |
- |
- |
| 0x1752 |
Sub-Tabelle |
0-n |
- |
0xFFFF |
- |
- |
- |
- |
| 0x1757 |
Signalqualität |
TEXT |
High |
8 |
- |
1.0 |
1.0 |
0.0 |
| 0x1758 |
Signalqualität |
TEXT |
High |
8 |
- |
1.0 |
1.0 |
0.0 |
| 0x175A |
Sub-Tabelle |
0-n |
- |
0xFFFF |
- |
- |
- |
- |
| 0x175B |
Sub-Tabelle |
0-n |
- |
0xFFFF |
- |
- |
- |
- |
| 0x4001 |
Voltage |
mV |
High |
unsigned int |
- |
1.0 |
1.0 |
0.0 |
| 0x4040 |
Sub-Tabelle |
0-n |
- |
0xFFFFFFFF |
- |
- |
- |
- |
| 0xXYXY |
unbekannte Umweltbedingung |
- |
- |
- |
- |
- |
- |
- |
IDETAILSTRUKTUR
Dimensions: 4 rows × 2 columns
| NAME |
TYP |
| F_UWB_ERW |
ja |
| SAE_CODE |
nein |
| F_HLZ |
nein |
| F_SEVERITY |
nein |
IORTTEXTE
Dimensions: 7 rows × 3 columns
| ORT |
ORTTEXT |
EREIGNIS_DTC |
| 0x100E00 |
Komponente vom Lifecycle ausgeschlossen |
1 |
| 0x101000 |
OSEK OS ErrorHook Fehler |
1 |
| 0x101002 |
Assert |
1 |
| 0x101003 |
OSEK OS Board Invalid |
1 |
| 0x930001 |
UnderVoltage Error-Versorgungsspannung: Mindestwert unterschritten |
1 |
| 0xCD4601 |
Ethernet: CRC Fehler |
1 |
| 0xFFFFFF |
unbekannter Fehlerort |
0 |
IUMWELTTEXTE
Dimensions: 20 rows × 9 columns
| UWNR |
UWTEXT |
UW_EINH |
L/H |
UWTYP |
NAME |
MUL |
DIV |
ADD |
| 0x0034 |
PORT_00_CRC_ERROR_COUNT |
0-n |
High |
0x0000000F |
PORT_CRC_ERROR_COUNT_4B_TAB |
- |
- |
- |
| 0x0035 |
PORT_01_CRC_ERROR_COUNT |
0-n |
High |
0x000000F0 |
PORT_CRC_ERROR_COUNT_4B_TAB |
- |
- |
- |
| 0x0036 |
PORT_02_CRC_ERROR_COUNT |
0-n |
High |
0x00000F00 |
PORT_CRC_ERROR_COUNT_4B_TAB |
- |
- |
- |
| 0x0037 |
PORT_03_CRC_ERROR_COUNT |
0-n |
High |
0x0000F000 |
PORT_CRC_ERROR_COUNT_4B_TAB |
- |
- |
- |
| 0x0038 |
PORT_04_CRC_ERROR_COUNT |
0-n |
High |
0x000F0000 |
PORT_CRC_ERROR_COUNT_4B_TAB |
- |
- |
- |
| 0x0039 |
PORT_05_CRC_ERROR_COUNT |
0-n |
High |
0x00F00000 |
PORT_CRC_ERROR_COUNT_4B_TAB |
- |
- |
- |
| 0x003A |
PORT_06_CRC_ERROR_COUNT |
0-n |
High |
0x0F000000 |
PORT_CRC_ERROR_COUNT_4B_TAB |
- |
- |
- |
| 0x003B |
PORT_07_CRC_ERROR_COUNT |
0-n |
High |
0xF0000000 |
PORT_CRC_ERROR_COUNT_4B_TAB |
- |
- |
- |
| 0x003C |
PORT_08_CRC_ERROR_COUNT |
0-n |
High |
0x0000000F |
PORT_CRC_ERROR_COUNT_4B_TAB |
- |
- |
- |
| 0x003D |
PORT_09_CRC_ERROR_COUNT |
0-n |
High |
0x000000F0 |
PORT_CRC_ERROR_COUNT_4B_TAB |
- |
- |
- |
| 0x003E |
PORT_10_CRC_ERROR_COUNT |
0-n |
High |
0x00000F00 |
PORT_CRC_ERROR_COUNT_4B_TAB |
- |
- |
- |
| 0x003F |
PORT_11_CRC_ERROR_COUNT |
0-n |
High |
0x0000F000 |
PORT_CRC_ERROR_COUNT_4B_TAB |
- |
- |
- |
| 0x0040 |
PORT_12_CRC_ERROR_COUNT |
0-n |
High |
0x000F0000 |
PORT_CRC_ERROR_COUNT_4B_TAB |
- |
- |
- |
| 0x0041 |
PORT_13_CRC_ERROR_COUNT |
0-n |
High |
0x00F00000 |
PORT_CRC_ERROR_COUNT_4B_TAB |
- |
- |
- |
| 0x0042 |
PORT_14_CRC_ERROR_COUNT |
0-n |
High |
0x0F000000 |
PORT_CRC_ERROR_COUNT_4B_TAB |
- |
- |
- |
| 0x0043 |
PORT_15_CRC_ERROR_COUNT |
0-n |
High |
0xF0000000 |
PORT_CRC_ERROR_COUNT_4B_TAB |
- |
- |
- |
| 0x1754 |
Sub-Tabelle |
0-n |
- |
0xFFFFFFFF |
- |
- |
- |
- |
| 0x1755 |
Sub-Tabelle |
0-n |
- |
0xFFFFFFFF |
- |
- |
- |
- |
| 0x4001 |
Voltage |
mV |
High |
unsigned int |
- |
1.0 |
1.0 |
0.0 |
| 0xXYXY |
unbekannte Umweltbedingung |
- |
- |
- |
- |
- |
- |
- |
JOBRESULTEXTENDED
Dimensions: 1 rows × 2 columns
| SB |
STATUS_TEXT |
| 0xXY |
ERROR_UNKNOWN |
LINK_RESET_STATUS_TAB
Dimensions: 2 rows × 2 columns
| WERT |
TEXT |
| 0x0 |
Linkverlust aufgrund SG-externen Ereignisses |
| 0x1 |
Linkverlust aufgrund SG-interen Ereignisses |
PHY_LINK_STATE_TAB
Dimensions: 16 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
Link down |
| 0x01 |
Link up |
| 0x02 |
Link up |
| 0x03 |
Link up |
| 0x04 |
Link up |
| 0x05 |
Link up |
| 0x06 |
Link up |
| 0x07 |
Link up |
| 0x08 |
Link up |
| 0x09 |
Link up |
| 0x0A |
Link up |
| 0x0B |
Link up |
| 0x0C |
Link up |
| 0x0D |
Link up |
| 0x0E |
Link up |
| 0x0F |
Link up |
PORT_CRC_ERROR_COUNT_4B_TAB
Dimensions: 121 rows × 2 columns
| WERT |
TEXT |
| 0x00000000 |
keine Frames verloren |
| 0x00000001 |
1-9 Frames verloren |
| 0x00000002 |
10-99 Frames verloren |
| 0x00000003 |
100-999 Frames verloren |
| 0x00000004 |
1000-9999 Frames verloren |
| 0x00000005 |
10000-99999 Frames verloren |
| 0x00000006 |
> 100000 Frames verloren |
| 0x00000007 |
reserviert |
| 0x00000008 |
reserviert |
| 0x00000009 |
reserviert |
| 0x0000000A |
reserviert |
| 0x0000000B |
reserviert |
| 0x0000000C |
reserviert |
| 0x0000000D |
reserviert |
| 0x0000000E |
Port nicht verbunden |
| 0x0000000F |
Anzahl der verlorenen Frames konnte nicht bestimmt werden. |
| 0x00000010 |
1-9 Frames verloren |
| 0x00000020 |
10-99 Frames verloren |
| 0x00000030 |
100-999 Frames verloren |
| 0x00000040 |
1000-9999 Frames verloren |
| 0x00000050 |
10000-99999 Frames verloren |
| 0x00000060 |
> 100000 Frames verloren |
| 0x00000070 |
reserviert |
| 0x00000080 |
reserviert |
| 0x00000090 |
reserviert |
| 0x000000A0 |
reserviert |
| 0x000000B0 |
reserviert |
| 0x000000C0 |
reserviert |
| 0x000000D0 |
reserviert |
| 0x000000E0 |
Port nicht verbunden |
| 0x000000F0 |
Anzahl der verlorenen Frames konnte nicht bestimmt werden. |
| 0x00000100 |
1-9 Frames verloren |
| 0x00000200 |
10-99 Frames verloren |
| 0x00000300 |
100-999 Frames verloren |
| 0x00000400 |
1000-9999 Frames verloren |
| 0x00000500 |
10000-99999 Frames verloren |
| 0x00000600 |
> 100000 Frames verloren |
| 0x00000700 |
reserviert |
| 0x00000800 |
reserviert |
| 0x00000900 |
reserviert |
| 0x00000A00 |
reserviert |
| 0x00000B00 |
reserviert |
| 0x00000C00 |
reserviert |
| 0x00000D00 |
reserviert |
| 0x00000E00 |
Port nicht verbunden |
| 0x00000F00 |
Anzahl der verlorenen Frames konnte nicht bestimmt werden. |
| 0x00001000 |
1-9 Frames verloren |
| 0x00002000 |
10-99 Frames verloren |
| 0x00003000 |
100-999 Frames verloren |
| 0x00004000 |
1000-9999 Frames verloren |
| 0x00005000 |
10000-99999 Frames verloren |
| 0x00006000 |
> 100000 Frames verloren |
| 0x00007000 |
reserviert |
| 0x00008000 |
reserviert |
| 0x00009000 |
reserviert |
| 0x0000A000 |
reserviert |
| 0x0000B000 |
reserviert |
| 0x0000C000 |
reserviert |
| 0x0000D000 |
reserviert |
| 0x0000E000 |
Port nicht verbunden |
| 0x0000F000 |
Anzahl der verlorenen Frames konnte nicht bestimmt werden. |
| 0x00010000 |
1-9 Frames verloren |
| 0x00020000 |
10-99 Frames verloren |
| 0x00030000 |
100-999 Frames verloren |
| 0x00040000 |
1000-9999 Frames verloren |
| 0x00050000 |
10000-99999 Frames verloren |
| 0x00060000 |
> 100000 Frames verloren |
| 0x00070000 |
reserviert |
| 0x00080000 |
reserviert |
| 0x00090000 |
reserviert |
| 0x000A0000 |
reserviert |
| 0x000B0000 |
reserviert |
| 0x000C0000 |
reserviert |
| 0x000D0000 |
reserviert |
| 0x000E0000 |
Port nicht verbunden |
| 0x000F0000 |
Anzahl der verlorenen Frames konnte nicht bestimmt werden. |
| 0x00100000 |
1-9 Frames verloren |
| 0x00200000 |
10-99 Frames verloren |
| 0x00300000 |
100-999 Frames verloren |
| 0x00400000 |
1000-9999 Frames verloren |
| 0x00500000 |
10000-99999 Frames verloren |
| 0x00600000 |
> 100000 Frames verloren |
| 0x00700000 |
reserviert |
| 0x00800000 |
reserviert |
| 0x00900000 |
reserviert |
| 0x00A00000 |
reserviert |
| 0x00B00000 |
reserviert |
| 0x00C00000 |
reserviert |
| 0x00D00000 |
reserviert |
| 0x00E00000 |
Port nicht verbunden |
| 0x00F00000 |
Anzahl der verlorenen Frames konnte nicht bestimmt werden. |
| 0x01000000 |
1-9 Frames verloren |
| 0x02000000 |
10-99 Frames verloren |
| 0x03000000 |
100-999 Frames verloren |
| 0x04000000 |
1000-9999 Frames verloren |
| 0x05000000 |
10000-99999 Frames verloren |
| 0x06000000 |
> 100000 Frames verloren |
| 0x07000000 |
reserviert |
| 0x08000000 |
reserviert |
| 0x09000000 |
reserviert |
| 0x0A000000 |
reserviert |
| 0x0B000000 |
reserviert |
| 0x0C000000 |
reserviert |
| 0x0D000000 |
reserviert |
| 0x0E000000 |
Port nicht verbunden |
| 0x0F000000 |
Anzahl der verlorenen Frames konnte nicht bestimmt werden. |
| 0x10000000 |
1-9 Frames verloren |
| 0x20000000 |
10-99 Frames verloren |
| 0x30000000 |
100-999 Frames verloren |
| 0x40000000 |
1000-9999 Frames verloren |
| 0x50000000 |
10000-99999 Frames verloren |
| 0x60000000 |
> 100000 Frames verloren |
| 0x70000000 |
reserviert |
| 0x80000000 |
reserviert |
| 0x90000000 |
reserviert |
| 0xA0000000 |
reserviert |
| 0xB0000000 |
reserviert |
| 0xC0000000 |
reserviert |
| 0xD0000000 |
reserviert |
| 0xE0000000 |
Port nicht verbunden |
| 0xF0000000 |
Anzahl der verlorenen Frames konnte nicht bestimmt werden. |
PORT_LINK_STATUS_TAB
Dimensions: 2 rows × 2 columns
| WERT |
TEXT |
| 0 |
kein Link-off festgestellt |
| 1 |
Link-off festgestellt |
RDBI_ADS_DOP
Dimensions: 10 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
ISOSAEReserved_00 |
| 0x01 |
defaultSession |
| 0x02 |
programmingSession |
| 0x03 |
extendedDiagnosticSession |
| 0x04 |
safetySystemDiagnosticSession |
| 0x40 |
vehicleManufacturerSpecific_40 |
| 0x41 |
codingSession |
| 0x42 |
SWTSession |
| 0x43 |
HDDUpdateSession |
| 0xff |
ungültig |
RES_0X1044_R
Dimensions: 1 rows × 13 columns
| RESULTNAME |
STR |
STPR |
RRR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_PHY_STOPPED_FOR_T_WERT |
- |
- |
+ |
s |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Verbleibende Dauer in Sekunden, in denen der gegebene PHY noch inaktiv ist. Wertebereich: 0 Sekunden - 255 Sekunden |
RES_0X1046_R
Dimensions: 1 rows × 13 columns
| RESULTNAME |
STR |
STPR |
RRR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_CABLE_DIAG_STATE |
+ |
- |
- |
0-n |
high |
unsigned char |
- |
CABLE_DIAG_STATE_TAB |
- |
- |
- |
Ergebnis der Kabeldiagnose. |
RES_0X1047_R
Dimensions: 3 rows × 13 columns
| RESULTNAME |
STR |
STPR |
RRR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_OUI_DATA |
+ |
- |
- |
DATA |
high |
data[4] |
- |
- |
1.0 |
1.0 |
0.0 |
24 Bit OUI des PHYs. Die restlichen Bits sind auf 0 zu setzen. |
| STAT_MMN_WERT |
+ |
- |
- |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Die 6 Bit lange MMN des Phys. Die übrigen Bits sollen auf 0 gesetzt werden. |
| STAT_REVISION_WERT |
+ |
- |
- |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
4 Bit lange Revisionsnummer des PHY. Die übrigen Bits sollen mit 0 belegt werden. |
RES_0X1049_R
Dimensions: 6 rows × 13 columns
| RESULTNAME |
STR |
STPR |
RRR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_NUMBER_OF_TRANSMITTED_PACKETS_WERT |
+ |
- |
- |
- |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Anzahl der Pakete, die erfolgreich am angegebenen Port verschickt wurden. Soll auf 0 gesetzt werden, wenn der Port nicht existiert oder der Port diesen Zähler nicht unterstützt. Im Falle eines Überlaufs ist der Wert 0xffffffff zurückzugeben. |
| STAT_BYTES_SENT_WERT |
+ |
- |
- |
- |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Anzahl der Bytes, die am angegebenen Port verschickt wurden. Soll auf 0 gesetzt werden, wenn der Port nicht existiert oder der Port diesen Zähler nicht unterstützt. Im Falle eines Überlaufs ist der Wert 0xffffffff zurückzugeben. |
| STAT_NUMBER_OF_DROPPED_TX_PACKETS_WERT |
+ |
- |
- |
- |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Anzahl der versandten Pakete am angegbenen Port, die auf Grund eines Mangels an Ressourcen (z.B. transmit FIFO underflow) verworfen wurden. Soll auf 0 gesetzt werden, wenn der Port nicht existiert oder der Port diesen Zähler nicht unterstützt. Im Falle eines Überlaufs ist der Wert 0xffffffff zurückzugeben. |
| STAT_NUMBER_OF_RECEIVED_PACKETS_WERT |
+ |
- |
- |
- |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Anzahl der erfolgreich empfangenen Pakete am angegebenen Port. Soll auf 0 gesetzt werden, wenn der Port nicht existiert oder der Port diesen Zähler nicht unterstützt. Im Falle eines Überlaufs ist der Wert 0xffffffff zurückzugeben. |
| STAT_STAT_BYTES_RECEIVED_WERT |
+ |
- |
- |
- |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Anzahl der empfangenen Bytes am angegebenen Port. Soll auf 0 gesetzt werden, wenn der Port nicht existiert oder der Port diesen Zähler nicht unterstützt. Im Falle eines Überlaufs ist der Wert 0xffffffff zurückzugeben. |
| STAT_NUMBER_OF_DROPPED_RX_PACKETS_WERT |
+ |
- |
- |
- |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Anzahl der empfangenen Pakete am angegbenen Port, die auf Grund eines Mangels an Ressourcen (z.B. voller input buffer ) verworfen wurden. Soll auf 0 gesetzt werden, wenn der Port nicht existiert oder der Port diesen Zähler nicht unterstützt. Im Falle eines Überlaufs ist der Wert 0xffffffff zurückzugeben. |
RES_0X104C_R
Dimensions: 1 rows × 13 columns
| RESULTNAME |
STR |
STPR |
RRR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_PHY_TEST_MODE |
+ |
- |
- |
0-n |
high |
unsigned char |
- |
ETH_PHY_TEST_MODE_STATE |
- |
- |
- |
Gibt an, ob das Schalten des PHY in den gewünschten Modus erfolgreich war. |
RES_0X1802_D
Dimensions: 2 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_NUM_OF_PORTS_WERT |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Anzahl der physikalischen Ports. |
| - |
Bit |
high |
BITFIELD |
- |
BF_PHY_LINK_STATE_BTFLD |
- |
- |
- |
Linkstatus aller Port. |
RES_0X1803_D
Dimensions: 2 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_LEARN_PORT_CONFIGURATION |
0-n |
high |
unsigned char |
- |
ETH_LEARN_PORT_CONFIGURATION |
- |
- |
- |
0: Lernen erfolgreich 1: Lernen nicht erfolgreich oder noch nicht gelernt |
| - |
Bit |
high |
BITFIELD |
- |
BF_ETH_PORT_CONFIGURATION |
- |
- |
- |
Pro Port 1Bit, das angibt ob LinkUp(1) oder kein Link (0) vorliegt. |
RES_0X2504_D
Dimensions: 6 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_ERASE_MEMORY_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
EraseMemoryTime, maximale SWE-Löschzeit mit Ablaufkontrolle im Steuergerät. |
| STAT_CHECK_MEMORY_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
CheckMemoryTime (Bsp.: Signaturprüfung), maximale Speicherprüfzeit mit Ablaufkontrolle im Steuergerät. |
| STAT_BOOTLOADER_INSTALLATION_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
BootloaderInstallationTime Die Zeit, die nach dem Reset benötigt wird, damit der Hilfsbootloader gestartet wird, den Bootloader löscht, den neuen Bootloader kopiert, dessen Signatur prüf und der neue Bootloader gestartet wird bis er wieder diagnosefähig ist. Angabe ist verpflichtend für alle Steuergeräte, auch wenn das Steuergerät keinen Bootloader Update geplant hat. Ein Wert von 0x0000 ist verboten. |
| STAT_AUTHENTICATION_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
AuthenticationTime, die maximale Zeit, die das Steuergerät zur Prüfung der Authentisierung (sendKey) benötigt mit Ablaufkontrolle im Steuergerät. |
| STAT_RESET_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
ResetTime Die Zeitangabe bezieht sich auf den Übergang von der ApplicationExtendedSesssion in die ProgrammingSession bzw. bei Übergang von der ProgrammingSession in die DefaultSession. Es ist der Maximalwert auszugeben. Nach Ablauf der ResetTime ist das Steuergerät durch Diagnose ansprechbar. |
| STAT_TRANSFER_DATA_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
TransferDataTime Die Angabe hat sich zu beziehen auf einen TransferData mit maximaler Blocklänge auf die Zeitspanne vom vollständigen Empfang der Daten im Steuergerät über das ggf. erforderliche Dekomprimieren und dem vollständigen Speichern im nichtflüchtigen Speicher bis einschließlich dem Senden der positiven Response. |
SG_FUNKTIONEN
Dimensions: 13 rows × 16 columns
| ARG |
ID |
RESULTNAME |
INFO |
EINHEIT |
LABEL |
L/H |
DATENTYP |
NAME |
MUL |
DIV |
ADD |
SG_ADR |
SERVICE |
ARG_TABELLE |
RES_TABELLE |
| ETH_PHY_SWITCH_ENGINE_RESET |
0x1044 |
- |
Wird verwendet, um einen PHY oder Switch/es zurpükzusetzen und optional im Zustand Reset zu halten. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
- |
RES_0x1044_R |
| STEUERN_CABLE_DIAG |
0x1046 |
- |
Startet die Kabeldiagnose des PHYs. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
ARG_0x1046_R |
RES_0x1046_R |
| ETH_PHY_IDENTIFIER |
0x1047 |
- |
Gibt den eindeutigen PHY-Identifier zurück. Dieser wird durch den 24 Bit langen Organizationally Unique Identifier (OUI), die 6 Bit lange Manufacturer's Model Number sowie die 4 Bit lange Revision Number gebildet. Die Werte sind standardisiert und stets in Register 2 und 3 des PHYs enthalten. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
ARG_0x1047_R |
RES_0x1047_R |
| ETH_GET_PORT_TX_RX_STATS |
0x1049 |
- |
Liest die Anzahl der verschickten und empfangenen Pakete, die Anzahl verworfenen Pakete und die Anzahl der übertragenen und empfangenen Bytes. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
ARG_0x1049_R |
RES_0x1049_R |
| ETH_RESET_PORT_CONFIGURATION |
0x104A |
- |
Setzt die gespeicherte Portkonfiguration zurück. Für ECUs mit mehr als 1 Port verpflichtend umzusetzen. Für ECUs mit 1 Port: Verpflichtend umzusetzen für SP2018 Steuergeräte, optional für SP2015 Steuergeräte. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
- |
- |
| ETH_RESET_PORT_TX_RX_STATS |
0x104B |
- |
Setzt die Receive- und Transmitzähler eines Switchs zurück. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
- |
- |
| ETH_ENABLE_TEST_MODE |
0x104C |
- |
Schaltet den PHY in den Testmode |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
ARG_0x104C_R |
RES_0x104C_R |
| ETH_GET_NUMBER_OF_PORTS |
0x1800 |
STAT_NUM_PORTS_WERT |
Anzahl der Ports |
- |
- |
High |
unsigned char |
- |
1.0 |
1.0 |
0.0 |
- |
22 |
- |
- |
| ETH_PHY_LINK_STATE |
0x1802 |
- |
Gibt den aktuellen Link-Status aller physikalisch vorhandenen Ports zurück. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
22 |
- |
RES_0x1802_D |
| ETH_LEARN_PORT_CONFIGURATION |
0x1803 |
- |
Gibt die gelernte Port-Konfiguration des SGs zurück. Für ECUs mit mehr als 1 Port verpflichtend umzusetzen. Für ECUs mit 1 Port: Verpflichtend umzusetzen für SP2018 Steuergeräte, optional für SP2015 Steuergeräte. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
22 |
- |
RES_0x1803_D |
| READ_SYNC_TIMING_INFORMATION |
0x1820 |
STAT_DMCS_DATA |
Auslesend der DMCS Debugwerte. |
DATA |
- |
High |
data[98] |
- |
1.0 |
1.0 |
0.0 |
- |
22 |
- |
- |
| FLASH_TIMING_PARAMETER |
0x2504 |
- |
Programmierspezifische Timing Parameter |
- |
- |
- |
- |
- |
- |
- |
- |
- |
22 |
- |
RES_0x2504_D |
| ACTIVE_DIAGNOSTIC_SESSION |
0xF186 |
STAT_ACTIVE_DIAGNOSTIC_SESSION |
activeDiagnosticSession |
0-n |
- |
High |
unsigned char |
RDBI_ADS_DOP |
- |
- |
- |
- |
22 |
- |
- |
TAB_0X1752
Dimensions: 1 rows × 17 columns
| UW_ANZ |
UW1_NR |
UW2_NR |
UW3_NR |
UW4_NR |
UW5_NR |
UW6_NR |
UW7_NR |
UW8_NR |
UW9_NR |
UW10_NR |
UW11_NR |
UW12_NR |
UW13_NR |
UW14_NR |
UW15_NR |
UW16_NR |
| 16 |
0x0021 |
0x0022 |
0x0023 |
0x0024 |
0x0025 |
0x0026 |
0x0027 |
0x0028 |
0x0029 |
0x002A |
0x002B |
0x002C |
0x002D |
0x002E |
0x002F |
0x0030 |
TAB_0X1754
Dimensions: 1 rows × 9 columns
| UW_ANZ |
UW1_NR |
UW2_NR |
UW3_NR |
UW4_NR |
UW5_NR |
UW6_NR |
UW7_NR |
UW8_NR |
| 8 |
0x0034 |
0x0035 |
0x0036 |
0x0037 |
0x0038 |
0x0039 |
0x003A |
0x003B |
TAB_0X1755
Dimensions: 1 rows × 9 columns
| UW_ANZ |
UW1_NR |
UW2_NR |
UW3_NR |
UW4_NR |
UW5_NR |
UW6_NR |
UW7_NR |
UW8_NR |
| 8 |
0x003C |
0x003D |
0x003E |
0x003F |
0x0040 |
0x0041 |
0x0042 |
0x0043 |
TAB_0X175A
Dimensions: 1 rows × 17 columns
| UW_ANZ |
UW1_NR |
UW2_NR |
UW3_NR |
UW4_NR |
UW5_NR |
UW6_NR |
UW7_NR |
UW8_NR |
UW9_NR |
UW10_NR |
UW11_NR |
UW12_NR |
UW13_NR |
UW14_NR |
UW15_NR |
UW16_NR |
| 16 |
0x0001 |
0x0002 |
0x0003 |
0x0004 |
0x0005 |
0x0006 |
0x0007 |
0x0008 |
0x0009 |
0x000A |
0x000B |
0x000C |
0x000D |
0x000E |
0x000F |
0x0010 |
TAB_0X175B
Dimensions: 1 rows × 17 columns
| UW_ANZ |
UW1_NR |
UW2_NR |
UW3_NR |
UW4_NR |
UW5_NR |
UW6_NR |
UW7_NR |
UW8_NR |
UW9_NR |
UW10_NR |
UW11_NR |
UW12_NR |
UW13_NR |
UW14_NR |
UW15_NR |
UW16_NR |
| 16 |
0x0011 |
0x0012 |
0x0013 |
0x0014 |
0x0015 |
0x0016 |
0x0017 |
0x0018 |
0x0019 |
0x001A |
0x001B |
0x001C |
0x001D |
0x001E |
0x001F |
0x0020 |
TAB_0X4040
Dimensions: 1 rows × 4 columns
| UW_ANZ |
UW1_NR |
UW2_NR |
UW3_NR |
| 3 |
0x0031 |
0x0032 |
0x0033 |
UNEXPECTED_LINK_UP_STATUS_TAB
Dimensions: 2 rows × 2 columns
| WERT |
TEXT |
| 0 |
für unbelegte Ports kein Link-up festgestellt bzw. Link auf Port zulässig |
| 1 |
Link-up auf eigentlich unbelegtem Port festgestellt |