RLM_2L.prg
INFO
| Field |
Value |
| ECU |
Rücklichtmodul Heckklappe 2 Links |
| ORIGIN |
BMW EK-522 Josef_Berwanger |
| REVISION |
3.005 |
| AUTHOR |
BMW EK-522 Kebsi |
| COMMENT |
- |
| PACKAGE |
1.987 |
| SPRACHE |
deutsch |
Jobs
Index
- INFO - Information SGBD
- INITIALISIERUNG - Initialisierung und Kommunikationsparameter
- IDENT - Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
- FS_LESEN - Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
- FS_LESEN_DETAIL - Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
- FS_LOESCHEN - Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
- PRUEFSTEMPEL_LESEN - Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
- PRUEFSTEMPEL_SCHREIBEN - Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
- SVK_LESEN - Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
- STATUS_LESEN - Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
- STEUERN - Vorgeben eines Status UDS : $2E WriteDataByIdentifier
- SERIENNUMMER_LESEN - Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
- STEUERN_ROUTINE - Vorgeben eines Status UDS : $31 RoutineControl
- FS_SPERREN - Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
- IS_LESEN - Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $17 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
- IS_LESEN_DETAIL - sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $19 ReadDTCInformation UDS : $18 reportDTCSnapshotRecordByDTCNumber UDS : $19 reportDTCExtendedDataRecordByDTCNumber UDS : $-- reportSeverityInformationOfDTC (nicht möglich!) Modus: Default
- IS_LOESCHEN - Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default
- HERSTELLINFO_LESEN - Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
- DIAGNOSE_AUFRECHT - Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
- DIAGNOSE_MODE - SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
- ENERGIESPARMODE - Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
- STATUS_ENERGIESPARMODE - Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
- STATUS_BETRIEBSMODE - Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default
- STEUERN_BETRIEBSMODE - Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default
- STEUERGERAETE_RESET - Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
- STATUS_ROE_REPORT - Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS: $86 ResponseOnEvent $04 report activated events $02 eventWindowTime - infinite (LH Diagnosemaster V11 oder höher, Umsetzung nach LH V6 - V10 wird jedoch toleriert)
- STEUERN_ROE_PERSISTENT_STOP - Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
- STEUERN_ROE_PERSISTENT_START - Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
- CPS_LESEN - Codierpruefstempel lesen UDS : $22 ReadDataByIdentifier UDS : $37FE DataIdentifier Codierpruefstempel Modus: Default
INFO
Information SGBD
No arguments.
Results
| Name |
Type |
Comment |
| ECU |
string |
Steuergerät im Klartext |
| ORIGIN |
string |
Steuergeräte-Verantwortlicher |
| REVISION |
string |
Versions-Nummer |
| AUTHOR |
string |
Namen aller Autoren |
| COMMENT |
string |
wichtige Hinweise |
| PACKAGE |
string |
Include-Paket-Nummer |
| SPRACHE |
string |
deutsch, english |
INITIALISIERUNG
Initialisierung und Kommunikationsparameter
No arguments.
Results
| Name |
Type |
Comment |
| DONE |
int |
1, wenn Okay |
IDENT
Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| ID_SG_ADR |
long |
Steuergeraeteadresse |
| ID_SGBD_INDEX |
long |
Index zur Erkennung der SG-Variante |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
FS_LESEN
Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
Arguments
| Name |
Type |
Comment |
| FEHLER_KLASSE |
string |
'IGNORIERE_EREIGNIS_DTC': Wenn EREIGNIS_DTC = '1', DTC-Fehlereinträge werden ignoriert sonst: FEHLERKLASSE wird ausgewertet |
Results
| Name |
Type |
Comment |
| F_VERSION |
int |
Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE |
binary |
Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR |
long |
Index fuer Fehlerort |
| F_ORT_TEXT |
string |
Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC |
int |
0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC -1: wird nicht unterstuetzt table FOrtTexte EREIGNIS_DTC |
| F_FEHLERKLASSE |
unsigned long |
table FOrtTexte FEHLERKLASSE |
| F_STATUSBYTE |
int |
Wert des DTC-Statusbyte laut ISO 14229 (bitcodiert) Bedeutung der einzelnen Bits: Bit 7: warningIndicatorRequested Bit 6: testNotCompletedThisOperationCycle Bit 5: testFailedSinceLastClear Bit 4: testNotCompletedSinceLastClear Bit 3: ConfirmedDTC Bit 2: PendingDTC Bit 1: testFailedThisOperationCycle Bit 0: testFailed |
| F_READY_NR |
int |
Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT |
string |
Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR |
int |
Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT |
string |
Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR |
int |
Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT |
string |
Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
FS_LESEN_DETAIL
Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
Arguments
| Name |
Type |
Comment |
| F_CODE |
long |
gewaehlter Fehlercode |
Results
| Name |
Type |
Comment |
| F_VERSION |
int |
Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE |
binary |
Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR |
long |
Index fuer Fehlerort |
| F_ORT_TEXT |
string |
Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC |
int |
0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_STATUSBYTE |
int |
Wert des DTC-Statusbyte laut ISO 14229 (bitcodiert) Bedeutung der einzelnen Bits: Bit 7: warningIndicatorRequested Bit 6: testNotCompletedThisOperationCycle Bit 5: testFailedSinceLastClear Bit 4: testNotCompletedSinceLastClear Bit 3: ConfirmedDTC Bit 2: PendingDTC Bit 1: testFailedThisOperationCycle Bit 0: testFailed |
| F_READY_NR |
int |
Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT |
string |
Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR |
int |
Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT |
string |
Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR |
int |
Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT |
string |
Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_HFK |
int |
Haeufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf |
| F_HLZ |
int |
Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Heilungsszaehler |
| F_UEBERLAUF |
int |
0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers |
| F_FEHLERKLASSE_NR |
int |
0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich ! |
| F_FEHLERKLASSE_TEXT |
string |
Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT |
| F_UW_ANZ |
int |
Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung |
| F_UW_KM |
long |
Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht |
| F_UW_ZEIT |
long |
Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_UW_BN |
int |
Umweltbedingung Basisnetz (1 Byte) -1, wenn Daten bzgl. Basisnetz nicht zur Verfuegung stehen |
| F_UW_TN |
long |
Umweltbedingung Teilnetz (3 Byte) -1, wenn Daten bzgl. funktionalem Teilnetz nicht zur Verfuegung stehen |
| F_SAE_CODE |
unsigned int |
Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD |
| F_SAE_CODE_STRING |
string |
5 stelliger Text in der Form 'Sxxxx' |
| F_SAE_CODE_TEXT |
string |
Text zu F_SAE_CODE |
| _RESPONSE_SNAPSHOT |
binary |
Hex-Antwort von SG |
| _RESPONSE_EXTENDED_DATA |
binary |
Hex-Antwort von SG |
| _RESPONSE_SEVERITY |
binary |
Hex-Antwort von SG |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
FS_LOESCHEN
Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
Arguments
| Name |
Type |
Comment |
| F_CODE |
long |
0x??????: Angabe eines einzelnen Fehlers Default: 0xFFFFFF: alle Fehler |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
PRUEFSTEMPEL_LESEN
Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| BYTE1 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE2 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE3 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
PRUEFSTEMPEL_SCHREIBEN
Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
Arguments
| Name |
Type |
Comment |
| BYTE1 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE2 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE3 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
SVK_LESEN
Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
Arguments
| Name |
Type |
Comment |
| SVK |
string |
table SVK_ID BEZEICHNUNG WERT default SVK_AKTUELL |
Results
| Name |
Type |
Comment |
| PROG_TEST |
int |
Programmierabhaengigkeiten (ProgrammingDependenciesChecked) 1: IO : Signaturpruefung und ProgrammingDependenciesCheck erfolgreich 2: NIO: mindestens eine SWE fehlerhaft oder ProgrammingDependenciesCheck nicht durchgefuehrt 3: NIO: mindestens eine SWE passt nicht mit einer HWE zusammen 4: NIO: mindestens eine SWE passt nicht mit einer anderen SWE zusammen sonst: reserviert |
| ANZAHL_EINHEITEN |
int |
Anzahl der xWEn |
| PROG_DATUM |
string |
Programmierdatum (DD.MM.YY) |
| PROG_KM |
long |
KM-Stand bei Programmierung (10 KM bis 655350 KM) Inkrement sind 10 KM -1: KM-Stand wird nicht unterstuetzt |
| PROZESSKLASSE_WERT |
int |
table Prozessklassen WERT dezimale Angabe der Prozessklasse |
| PROZESSKLASSE_TEXT |
string |
table Prozessklassen BEZEICHNUNG Text-Angabe der Prozessklasse |
| PROZESSKLASSE_KURZTEXT |
string |
table Prozessklassen PROZESSKLASSE Text-Angabe des Prozessklassenkurztextes |
| SGBM_IDENTIFIER |
string |
Angabe SGBM-ID der Prozessklasse |
| VERSION |
string |
Angabe der Version der Prozessklasse |
| SGBM_ID |
string |
Angabe von Prozessklasse, SGBM-Identifier, Version |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STATUS_LESEN
Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
Arguments
| Name |
Type |
Comment |
| ARGUMENT_SPALTE |
string |
'ARG', 'ID', 'LABEL' |
| STATUS |
string |
Es muss mindestens ein Argument übergeben werden Es wird das zugehörige result erzeugt table SG_Funktionen ARG ID RESULTNAME RES_TABELLE ARG_TABELLE |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Antwort von SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN
Vorgeben eines Status UDS : $2E WriteDataByIdentifier
Arguments
| Name |
Type |
Comment |
| ARGUMENT_SPALTE |
string |
'ARG', 'ID', 'LABEL' |
| STATUS |
string |
Siehe table SG_Funktionen ARG ID LABEL ARG_TABELLE |
| WERT |
string |
Es muss mindestens ein Argument übergeben werden Argumente siehe table SG_Funktionen ARG ID ARG_TABELLE |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Antwort von SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
SERIENNUMMER_LESEN
Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| SERIENNUMMER |
string |
Seriennummer des Steuergeraets |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN_ROUTINE
Vorgeben eines Status UDS : $31 RoutineControl
Arguments
| Name |
Type |
Comment |
| ARGUMENT_SPALTE |
string |
'ARG', 'ID', 'LABEL' |
| STATUS |
string |
Siehe table SG_Funktionen ARG ID RES_TABELLE ARG_TABELLE |
| STEUERPARAMETER |
string |
'STR' = startRoutine 'STPR' = stopRoutine 'RRR' = requestRoutineResults |
| WERT |
string |
Argumente siehe table SG_Funktionen ARG_TABELLE |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Antwort von SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
FS_SPERREN
Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
Arguments
| Name |
Type |
Comment |
| SPERREN |
string |
"ja" -> Fehlerspeicher sperren "nein" -> Fehlerspeicher freigeben table DigitalArgument TEXT Default: "ja" |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
IS_LESEN
Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $17 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
Arguments
| Name |
Type |
Comment |
| IGNORIERE_EREIGNIS_DTC |
string |
'IGNORIERE_EREIGNIS_DTC': Alle Ereignis DTC-Fehlereinträge werden ignoriert sonst: alle Fehlereinträge werden ausgegeben |
Results
| Name |
Type |
Comment |
| F_VERSION |
int |
Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE |
binary |
Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR |
long |
Index fuer Fehlerort |
| F_ORT_TEXT |
string |
Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC |
int |
0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_STATUSBYTE |
int |
Wert des DTC-Statusbyte laut ISO 14229 (bitcodiert) Bedeutung der einzelnen Bits: Bit 7: warningIndicatorRequested Bit 6: testNotCompletedThisOperationCycle Bit 5: testFailedSinceLastClear Bit 4: testNotCompletedSinceLastClear Bit 3: ConfirmedDTC Bit 2: PendingDTC Bit 1: testFailedThisOperationCycle Bit 0: testFailed |
| F_READY_NR |
int |
Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT |
string |
Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR |
int |
Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT |
string |
Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR |
int |
Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT |
string |
Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
IS_LESEN_DETAIL
sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $19 ReadDTCInformation UDS : $18 reportDTCSnapshotRecordByDTCNumber UDS : $19 reportDTCExtendedDataRecordByDTCNumber UDS : $-- reportSeverityInformationOfDTC (nicht möglich!) Modus: Default
Arguments
| Name |
Type |
Comment |
| F_CODE |
long |
gewaehlter Infocode |
Results
| Name |
Type |
Comment |
| F_VERSION |
int |
Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE |
binary |
Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR |
long |
Index fuer Fehlerort |
| F_ORT_TEXT |
string |
Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC |
int |
0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_STATUSBYTE |
int |
Wert des DTC-Statusbyte laut ISO 14229 (bitcodiert) Bedeutung der einzelnen Bits: Bit 7: warningIndicatorRequested Bit 6: testNotCompletedThisOperationCycle Bit 5: testFailedSinceLastClear Bit 4: testNotCompletedSinceLastClear Bit 3: ConfirmedDTC Bit 2: PendingDTC Bit 1: testFailedThisOperationCycle Bit 0: testFailed |
| F_READY_NR |
int |
Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT |
string |
Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR |
int |
Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT |
string |
Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR |
int |
Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT |
string |
Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_HFK |
int |
Haeufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf |
| F_HLZ |
int |
Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Heilungsszaehler |
| F_UEBERLAUF |
int |
0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers |
| F_FEHLERKLASSE_NR |
int |
0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich ! |
| F_FEHLERKLASSE_TEXT |
string |
Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT |
| F_UW_ANZ |
int |
Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung |
| F_UW_KM |
long |
Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht |
| F_UW_ZEIT |
long |
Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_UW_BN |
int |
Umweltbedingung Basisnetz (1 Byte) -1, wenn Daten bzgl. Basisnetz nicht zur Verfuegung stehen |
| F_UW_TN |
long |
Umweltbedingung Teilnetz (3 Byte) -1, wenn Daten bzgl. funktionalem Teilnetz nicht zur Verfuegung stehen |
| F_SAE_CODE |
unsigned int |
Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD |
| F_SAE_CODE_STRING |
string |
5 stelliger Text in der Form 'Sxxxx' |
| F_SAE_CODE_TEXT |
string |
Text zu F_SAE_CODE |
| _REQUEST_SNAPSHOT |
binary |
Anfrage ans SG |
| _REQUEST_EXTENDED_DATA |
binary |
Anfrage ans SG |
| _RESPONSE_SNAPSHOT |
binary |
Hex-Antwort von SG |
| _RESPONSE_EXTENDED_DATA |
binary |
Hex-Antwort von SG |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
IS_LOESCHEN
Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
HERSTELLINFO_LESEN
Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| ID_LIEF_NR |
long |
Lieferantennummer 0xFFFFFF, falls nicht vorhanden |
| ID_LIEF_TEXT |
string |
Text zu ID_LIEF_NR table Lieferanten LIEF_TEXT unbekannter Hersteller, falls nicht vorhanden |
| ID_DATUM |
string |
Herstelldatum (DD.MM.YY) |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
| _REQUEST_2 |
binary |
Hex-Auftrag an SG |
| _RESPONSE_2 |
binary |
Hex-Antwort von SG |
DIAGNOSE_AUFRECHT
Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
Arguments
| Name |
Type |
Comment |
| SG_ANTWORT |
string |
"ja" -> SG soll antworten "nein" -> SG soll nicht antworten table DigitalArgument TEXT Default: SG soll antworten |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
DIAGNOSE_MODE
SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
Arguments
| Name |
Type |
Comment |
| MODE |
string |
gewuenschter Diagnose-Modus table DiagMode MODE MODE_TEXT Defaultwert: DEFAULT (DefaultMode) |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
ENERGIESPARMODE
Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
Arguments
| Name |
Type |
Comment |
| MODE |
int |
0x00: Normalmode 0x01: Fertigungsmode 0x02: Transportmode 0x03: Flashmode |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STATUS_ENERGIESPARMODE
Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| STAT_ENERGIESPARMODE_WERT |
int |
Ausgabe des Energiesparmodes 0: Kein Energiesparmode gesetzt 1: Produktionsmode gesetzt 2: Transportmode gesetzt 3: Flashmode gesetzt -1: Mode ungueltig |
| STAT_ENERGIESPARMODE_TEXT |
string |
Text zu STAT_ENERGIESPARMODE_WERT |
| STAT_PRODUKTIONSMODE_EIN |
int |
0: Produktionsmode nicht aktiv 1: Produktionsmode aktiv |
| STAT_TRANSPORTMODE_EIN |
int |
0: Transportmode nicht aktiv 1: Transportmode aktiv |
| STAT_FLASHMODE_EIN |
int |
0: Flashmode nicht aktiv 1: Flashmode aktiv |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STATUS_BETRIEBSMODE
Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| STAT_BETRIEBSMODE_WERT |
int |
Aktueller Betriebsmode table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle) |
| STAT_BETRIEBSMODE_TEXT |
string |
Textausgabe STAT_BETRIEBSMODE_WERT table Betriebsmode TEXT |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN_BETRIEBSMODE
Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default
Arguments
| Name |
Type |
Comment |
| BETRIEBSMODE |
int |
Betriebsmode setzen table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle) |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERGERAETE_RESET
Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STATUS_ROE_REPORT
Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS: $86 ResponseOnEvent $04 report activated events $02 eventWindowTime - infinite (LH Diagnosemaster V11 oder höher, Umsetzung nach LH V6 - V10 wird jedoch toleriert)
No arguments.
Results
| Name |
Type |
Comment |
| STAT_ROE_AKTIV |
char |
0x00 = Aktive Fehlermeldung deaktiviert 0x01 = Aktive Fehlermeldung aktiviert 0xFF = Status der aktiven Fehlermeldung nicht feststellbar |
| STAT_ROE_AKTIV_TEXT |
string |
Interpretation von STAT_ROE_AKTIV table UDS_TAB_ROE_AKTIV TEXT |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN_ROE_PERSISTENT_STOP
Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
No arguments.
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN_ROE_PERSISTENT_START
Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
No arguments.
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
CPS_LESEN
Codierpruefstempel lesen UDS : $22 ReadDataByIdentifier UDS : $37FE DataIdentifier Codierpruefstempel Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| CPS |
string |
Codierpruefstempel bis SP2021 bestehend aus VIN7 7 Zeichen (ASCII) Codierpruefstempel ab SP2021 bestehend aus Codierdatum 6 Zeichen (3 Byte Hex) bestehend aus TesterNr 6 Zeichen (3 Byte Hex) bestehend aus LizenzID 10 Zeichen (5 Byte Hex) bestehend aus VIN7 7 Zeichen (ASCII) |
| CPS_VIN7 |
string |
7 Zeichen (ASCII) |
| CPS_DATUM |
string |
erst ab SP2021 Codierdatum 8 Zeichen TT.MM.JJJJ |
| CPS_TESTERNR |
string |
erst ab SP2021 Tester-Nummer 6 Zeichen hex |
| CPS_LIZENZID |
string |
erst ab SP2021 Tester-Lizenz-ID 10 Zeichen hex |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
Tables
Index
JOBRESULT
Dimensions: 76 rows × 2 columns
| SB |
STATUS_TEXT |
| 0x10 |
ERROR_ECU_GENERAL_REJECT |
| 0x11 |
ERROR_ECU_SERVICE_NOT_SUPPORTED |
| 0x12 |
ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED |
| 0x13 |
ERROR_ECU_INCORRECT_MESSAGE_LENGTH_OR_INVALID_FORMAT |
| 0x14 |
ERROR_ECU_RESPONSE_TOO_LONG |
| 0x21 |
ERROR_ECU_BUSY_REPEAT_REQUEST |
| 0x22 |
ERROR_ECU_CONDITIONS_NOT_CORRECT |
| 0x24 |
ERROR_ECU_REQUEST_SEQUENCE_ERROR |
| 0x25 |
ERROR_ECU_NO_RESPONSE_FROM_SUBNET_COMPONENT |
| 0x26 |
ERROR_ECU_FAILURE_PREVENTS_EXECUTION_OF_REQUESTED_ACTION |
| 0x31 |
ERROR_ECU_REQUEST_OUT_OF_RANGE |
| 0x33 |
ERROR_ECU_SECURITY_ACCESS_DENIED |
| 0x35 |
ERROR_ECU_INVALID_KEY |
| 0x36 |
ERROR_ECU_EXCEED_NUMBER_OF_ATTEMPTS |
| 0x37 |
ERROR_ECU_REQUIRED_TIME_DELAY_NOT_EXPIRED |
| 0x70 |
ERROR_ECU_UPLOAD_DOWNLOAD_NOT_ACCEPTED |
| 0x71 |
ERROR_ECU_TRANSFER_DATA_SUSPENDED |
| 0x72 |
ERROR_ECU_GENERAL_PROGRAMMING_FAILURE |
| 0x73 |
ERROR_ECU_WRONG_BLOCK_SEQUENCE_COUNTER |
| 0x78 |
ERROR_ECU_REQUEST_CORRECTLY_RECEIVED__RESPONSE_PENDING |
| 0x7E |
ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED_IN_ACTIVE_SESSION |
| 0x7F |
ERROR_ECU_SERVICE_NOT_SUPPORTED_IN_ACTIVE_SESSION |
| 0x81 |
ERROR_ECU_RPM_TOO_HIGH |
| 0x82 |
ERROR_ECU_RPM_TOO_LOW |
| 0x83 |
ERROR_ECU_ENGINE_IS_RUNNING |
| 0x84 |
ERROR_ECU_ENGINE_IS_NOT_RUNNING |
| 0x85 |
ERROR_ECU_ENGINE_RUN_TIME_TOO_LOW |
| 0x86 |
ERROR_ECU_TEMPERATURE_TOO_HIGH |
| 0x87 |
ERROR_ECU_TEMPERATURE_TOO_LOW |
| 0x88 |
ERROR_ECU_VEHICLE_SPEED_TOO_HIGH |
| 0x89 |
ERROR_ECU_VEHICLE_SPEED_TOO_LOW |
| 0x8A |
ERROR_ECU_THROTTLE_PEDAL_TOO_HIGH |
| 0x8B |
ERROR_ECU_THROTTLE_PEDAL_TOO_LOW |
| 0x8C |
ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_NEUTRAL |
| 0x8D |
ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_GEAR |
| 0x8F |
ERROR_ECU_BRAKE_SWITCH_NOT_CLOSED |
| 0x90 |
ERROR_ECU_SHIFTER_LEVER_NOT_IN_PARK |
| 0x91 |
ERROR_ECU_TORQUE_CONVERTER_CLUTCH_LOCKED |
| 0x92 |
ERROR_ECU_VOLTAGE_TOO_HIGH |
| 0x93 |
ERROR_ECU_VOLTAGE_TOO_LOW |
| ?00? |
OKAY |
| ?01? |
ERROR_ECU_NO_RESPONSE |
| ?02? |
ERROR_ECU_INCORRECT_LEN |
| ?03? |
ERROR_ECU_INCORRECT_RESPONSE_ID |
| ?04? |
ERROR_ECU_TA_RESPONSE_NOT_SA_REQUEST |
| ?05? |
ERROR_ECU_SA_RESPONSE_NOT_TA_REQUEST |
| ?06? |
ERROR_ECU_RESPONSE_INCORRECT_DATA_IDENTIFIER |
| ?07? |
ERROR_ECU_RESPONSE_TOO_MUCH_DATA |
| ?08? |
ERROR_ECU_RESPONSE_TOO_LESS_DATA |
| ?09? |
ERROR_ECU_RESPONSE_VALUE_OUT_OF_RANGE |
| ?0A? |
ERROR_TABLE |
| ?10? |
ERROR_F_CODE |
| ?12? |
ERROR_INTERPRETATION |
| ?13? |
ERROR_F_POS |
| ?14? |
ERROR_ECU_RESPONSE_INCORRECT_IO_CONTROL_PARAMETER |
| ?15? |
ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_CONTROL_TYPE |
| ?16? |
ERROR_ECU_RESPONSE_INCORRECT_SUB_FUNCTION |
| ?17? |
ERROR_ECU_RESPONSE_INCORRECT_DYNAMICALLY_DEFINED_DATA_IDENTIFIER |
| ?18? |
ERROR_ECU_RESPONSE_NO_STRING_END_CHAR |
| ?19? |
ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_IDENTIFIER |
| ?1A? |
ERROR_ECU_RESPONSE_INCORRECT_RESET_TYPE |
| ?1B? |
ERROR_ECU_RESPONSE_INCORRECT_SERIAL_NUMBER_FORMAT |
| ?1C? |
ERROR_ECU_RESPONSE_INCORRECT_DTC_BY_STATUS_MASK |
| ?1D? |
ERROR_ECU_RESPONSE_INCORRECT_DTC_STATUS_AVAILABILITY_MASK |
| ?1E? |
ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_CONTROL_IDENTIFIER |
| ?50? |
ERROR_BYTE1 |
| ?51? |
ERROR_BYTE2 |
| ?52? |
ERROR_BYTE3 |
| ?60? |
ERROR_VERIFY |
| ?61? |
ERROR_ECU_RESPONSE_ZGW |
| ?62? |
ERROR_ECU_RESPONSE_BACKUP |
| ?70? |
ERROR_CALID_CVN_INCORRECT_LEN |
| ?80? |
ERROR_SVK_INCORRECT_LEN |
| ?81? |
ERROR_SVK_INCORRECT_FINGERPRINT |
| ?F0? |
ERROR_ARGUMENT |
| 0xXY |
ERROR_ECU_UNKNOWN_NEGATIVE_RESPONSE |
LIEFERANTEN
Dimensions: 149 rows × 2 columns
| LIEF_NR |
LIEF_TEXT |
| 0x000001 |
Reinshagen / Delphi |
| 0x000002 |
Leopold Kostal GmbH & Co. KG |
| 0x000003 |
Hella Fahrzeugkomponenten GmbH |
| 0x000004 |
Siemens |
| 0x000005 |
Eaton |
| 0x000006 |
UTA |
| 0x000007 |
Helbako GmbH |
| 0x000008 |
Robert Bosch GmbH |
| 0x000009 |
Lear Corporation |
| 0x000010 |
VDO |
| 0x000011 |
Valeo GmbH |
| 0x000012 |
MBB |
| 0x000013 |
Kammerer |
| 0x000014 |
SWF |
| 0x000015 |
Blaupunkt |
| 0x000016 |
Philips |
| 0x000017 |
Alpine Electronics GmbH |
| 0x000018 |
Continental Teves AG & Co. OHG |
| 0x000019 |
Elektromatik Südafrika |
| 0x000020 |
Harman Becker Automotive Systems |
| 0x000021 |
Preh GmbH |
| 0x000022 |
Alps Electric Co. Ltd. |
| 0x000023 |
Motorola |
| 0x000024 |
Temic |
| 0x000025 |
Webasto SE |
| 0x000026 |
MotoMeter |
| 0x000027 |
Delphi Automotive PLC |
| 0x000028 |
DODUCO (Beru) |
| 0x000029 |
DENSO |
| 0x000030 |
NEC |
| 0x000031 |
DASA |
| 0x000032 |
Pioneer Corporation |
| 0x000033 |
Jatco |
| 0x000034 |
FUBA Automotive GmbH & Co. KG |
| 0x000035 |
UK-NSI |
| 0x000036 |
AABG |
| 0x000037 |
Dunlop |
| 0x000038 |
Sachs |
| 0x000039 |
ITT |
| 0x000040 |
FTE (Fahrzeugtechnik Ebern) |
| 0x000041 |
Megamos |
| 0x000042 |
TRW Automotive GmbH |
| 0x000043 |
WABCO Fahrzeugsysteme GmbH |
| 0x000044 |
ISAD Electronic Systems |
| 0x000045 |
HEC Hella Electronics Corporation |
| 0x000046 |
Gemel |
| 0x000047 |
ZF Friedrichshafen AG |
| 0x000048 |
GMPT |
| 0x000049 |
Harman Becker Automotive Systems GmbH |
| 0x000050 |
Remes GmbH |
| 0x000051 |
ZF Lenksysteme GmbH |
| 0x000052 |
Magneti Marelli S.p.A. |
| 0x000053 |
Johnson Controls Inc. |
| 0x000054 |
GETRAG Getriebe- und Zahnradf. Hermann Hagenmeyer GmbH & Co. KG |
| 0x000055 |
Behr-Hella Thermocontrol GmbH |
| 0x000056 |
Siemens VDO Automotive |
| 0x000057 |
Visteon Innovation & Technology GmbH |
| 0x000058 |
Autoliv AB |
| 0x000059 |
Haberl Electronic GmbH & Co. KG |
| 0x000060 |
Magna International Inc. |
| 0x000061 |
Marquardt GmbH |
| 0x000062 |
AB Elektronik GmbH |
| 0x000063 |
SDVO/BORG |
| 0x000064 |
Hirschmann Car Communication GmbH |
| 0x000065 |
hoerbiger-electronics |
| 0x000066 |
Thyssen Krupp Automotive |
| 0x000067 |
Gentex Corporation |
| 0x000068 |
Atena GmbH |
| 0x000069 |
Magna-Donelly |
| 0x000070 |
Koyo Steeting Europe |
| 0x000071 |
NSI Beheer B.V. |
| 0x000072 |
Aisin AW Co. Ltd. |
| 0x000073 |
Schorlock |
| 0x000074 |
Schrader Electronics Ltd. |
| 0x000075 |
Huf-Electronics Bretten GmbH |
| 0x000076 |
CEL |
| 0x000077 |
AUDIO MOBIL Elektronik GmbH |
| 0x000078 |
rd electronic |
| 0x000079 |
iSYS RTS GmbH |
| 0x000080 |
Westfalia-Automotive GmbH |
| 0x000081 |
Tyco Electronics |
| 0x000082 |
Paragon AG |
| 0x000083 |
IEE S.A. |
| 0x000084 |
TEMIC AUTOMOTIVE of NA |
| 0x000085 |
Sonceboz S.A. |
| 0x000086 |
Meta System S.p.A. |
| 0x000087 |
Huf Hülsbeck & Fürst GmbH & Co. KG |
| 0x000088 |
MANN+HUMMEL GmbH |
| 0x000089 |
Brose Fahrzeugteile GmbH & Co. |
| 0x000090 |
Keihin |
| 0x000091 |
Vimercati S.p.a |
| 0x000092 |
CRH |
| 0x000093 |
TPO Display Corp |
| 0x000094 |
Küster Automotive GmbH |
| 0x000095 |
Hitachi Automotive |
| 0x000096 |
Continental AG |
| 0x000097 |
TI-Automotive |
| 0x000098 |
Hydro |
| 0x000099 |
Johnson Controls Inc. |
| 0x00009A |
Takata-Petri |
| 0x00009B |
Mitsubishi Electric B.V. (Melco) |
| 0x00009C |
Autokabel |
| 0x00009D |
GKN Plc |
| 0x00009E |
Zollner Elektronik AG |
| 0x00009F |
peiker acustic GmbH & Co. KG |
| 0x0000A0 |
Bosal-Oris |
| 0x0000A1 |
Cobasys |
| 0x0000A2 |
Automotive Lighting Reutlingen GmbH |
| 0x0000A3 |
CONTI VDO |
| 0x0000A4 |
A.D.C. Automotive Distance Control Systems GmbH |
| 0x0000A5 |
Novero Dabendorf GmbH |
| 0x0000A6 |
LAMES S.p.a. |
| 0x0000A7 |
Magna/Closures |
| 0x0000A8 |
Harbin Wan Yu Technology Co |
| 0x0000A9 |
ThyssenKrupp Presta AG |
| 0x0000AA |
ArvinMeritor |
| 0x0000AB |
Kongsberg Automotive GmbH |
| 0x0000AC |
SMR Automotive Mirrors Stuttgart GmbH |
| 0x0000AD |
So.Ge.Mi. |
| 0x0000AE |
MTA S.p.A. |
| 0x0000AF |
Alfmeier Präzision AG |
| 0x0000B0 |
Eltek Deutechland GmbH |
| 0x0000B1 |
OMRON Automotive Electronics Europe GmbH |
| 0x0000B2 |
ASK Industries GmbH |
| 0x0000B3 |
CML Innovative Technologies GmbH & Co. KG |
| 0x0000B4 |
APAG Elektronik AG |
| 0x0000B5 |
Nexteer Automotive |
| 0x0000B6 |
Hans Widmaier Fernmelde- und Feinwerktechnik |
| 0x0000B7 |
Robert Bosch Battery Systems GmbH |
| 0x0000B8 |
Kyocera Display Europe GmbH |
| 0x0000B9 |
Magna Powertrain AG & Co. KG |
| 0x0000BA |
BorgWarner Beru Systems GmbH |
| 0x0000BB |
BMW AG |
| 0x0000BC |
Benteler Duncan Plant |
| 0x0000BD |
U-Shin Deutschland Zugangssysteme GmbH |
| 0x0000BE |
Schaeffler Technologies AG & Co. KG |
| 0x0000BF |
JTEKT Corporation |
| 0x0000C0 |
VLF |
| 0x0000C1 |
Flextronics |
| 0x0000C2 |
LG Chem |
| 0x0000C3 |
Panasonic |
| 0x0000C4 |
Alpitronic GmbH |
| 0x0000C5 |
Telemotive AG |
| 0x0000C6 |
Garmin |
| 0x0000C7 |
RSG Elotech Elektronische Baugruppen GmbH |
| 0x0000C8 |
KEBODA TECHNOLOGY CORP |
| 0x0000C9 |
Aptiv |
| 0x0000CA |
SEG Automotive Germany GmbH |
| 0xFFFFFF |
unbekannter Hersteller |
FARTTEXTE
Dimensions: 35 rows × 2 columns
| ARTNR |
ARTTEXT |
| 0x00 |
keine Fehlerart verfügbar |
| 0x04 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x05 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x08 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x09 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x0C |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x0D |
Fehler momentan vorhanden und bereits gespeichert |
| 0x20 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x21 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x24 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x25 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x28 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x29 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x2C |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x2D |
Fehler momentan vorhanden und bereits gespeichert |
| 0x40 |
unbekannte Fehlerart |
| 0x44 |
Fehler gespeichert |
| 0x45 |
Fehler gespeichert |
| 0x48 |
Fehler gespeichert |
| 0x49 |
Fehler gespeichert |
| 0x4C |
Fehler gespeichert |
| 0x4D |
Fehler gespeichert |
| 0x60 |
Fehler gespeichert |
| 0x61 |
Fehler gespeichert |
| 0x64 |
Fehler gespeichert |
| 0x65 |
Fehler gespeichert |
| 0x68 |
Fehler gespeichert |
| 0x69 |
Fehler gespeichert |
| 0x6C |
Fehler gespeichert |
| 0x6D |
Fehler gespeichert |
| 0x10 |
Testbedingungen erfüllt |
| 0x11 |
Testbedingungen noch nicht erfüllt |
| 0x80 |
Fehler würde kein Aufleuchten einer Warnlampe verursachen |
| 0x81 |
Fehler würde das Aufleuchten einer Warnlampe verursachen |
| 0xFF |
unbekannte Fehlerart |
DIGITALARGUMENT
Dimensions: 17 rows × 2 columns
| TEXT |
WERT |
| ein |
1 |
| aus |
0 |
| ja |
1 |
| nein |
0 |
| auf |
1 |
| ab |
0 |
| an |
1 |
| yes |
1 |
| no |
0 |
| on |
1 |
| off |
0 |
| up |
1 |
| down |
0 |
| true |
1 |
| false |
0 |
| 1 |
1 |
| 0 |
0 |
PROZESSKLASSEN
Dimensions: 26 rows × 3 columns
| WERT |
PROZESSKLASSE |
BEZEICHNUNG |
| 0x00 |
- |
ungueltig |
| 0x01 |
HWEL |
Hardware (Elektronik) |
| 0x02 |
HWAP |
Hardwareauspraegung |
| 0x03 |
HWFR |
Hardwarefarbe |
| 0x05 |
CAFD |
Codierdaten |
| 0x06 |
BTLD |
Bootloader |
| 0x08 |
SWFL |
Software ECU Speicherimage |
| 0x09 |
SWFF |
Flash File Software |
| 0x0A |
SWPF |
Pruefsoftware |
| 0x0B |
ONPS |
Onboard Programmiersystem |
| 0x0F |
FAFP |
FA2FP |
| 0x1A |
TLRT |
Temporaere Loeschroutine |
| 0x1B |
TPRG |
Temporaere Programmierroutine |
| 0x07 |
FLSL |
Flashloader Slave |
| 0x0C |
IBAD |
Interaktive Betriebsanleitung Daten |
| 0x10 |
FCFA |
Freischaltcode Fahrzeug-Auftrag |
| 0x1C |
BLUP |
Bootloader-Update Applikation |
| 0x1D |
FLUP |
Flashloader-Update Applikation |
| 0xC0 |
SWUP |
Software-Update Package |
| 0xC1 |
SWIP |
Index Software-Update Package |
| 0xA0 |
ENTD |
Entertainment Daten |
| 0xA1 |
NAVD |
Navigation Daten |
| 0xA2 |
FCFN |
Freischaltcode Funktion |
| 0x04 |
GWTB |
Gateway-Tabelle |
| 0x0D |
SWFK |
BEGU: Detaillierung auf SWE-Ebene |
| 0xFF |
- |
ungueltig |
SVK_ID
Dimensions: 65 rows × 2 columns
| WERT |
BEZEICHNUNG |
| 0x01 |
SVK_AKTUELL |
| 0x02 |
SVK_SUPPLIER |
| 0x03 |
SVK_WERK |
| 0x04 |
SVK_BACKUP_01 |
| 0x05 |
SVK_BACKUP_02 |
| 0x06 |
SVK_BACKUP_03 |
| 0x07 |
SVK_BACKUP_04 |
| 0x08 |
SVK_BACKUP_05 |
| 0x09 |
SVK_BACKUP_06 |
| 0x0A |
SVK_BACKUP_07 |
| 0x0B |
SVK_BACKUP_08 |
| 0x0C |
SVK_BACKUP_09 |
| 0x0D |
SVK_BACKUP_10 |
| 0x0E |
SVK_BACKUP_11 |
| 0x0F |
SVK_BACKUP_12 |
| 0x10 |
SVK_BACKUP_13 |
| 0x11 |
SVK_BACKUP_14 |
| 0x12 |
SVK_BACKUP_15 |
| 0x13 |
SVK_BACKUP_16 |
| 0x14 |
SVK_BACKUP_17 |
| 0x15 |
SVK_BACKUP_18 |
| 0x16 |
SVK_BACKUP_19 |
| 0x17 |
SVK_BACKUP_20 |
| 0x18 |
SVK_BACKUP_21 |
| 0x19 |
SVK_BACKUP_22 |
| 0x1A |
SVK_BACKUP_23 |
| 0x1B |
SVK_BACKUP_24 |
| 0x1C |
SVK_BACKUP_25 |
| 0x1D |
SVK_BACKUP_26 |
| 0x1E |
SVK_BACKUP_27 |
| 0x1F |
SVK_BACKUP_28 |
| 0x20 |
SVK_BACKUP_29 |
| 0x21 |
SVK_BACKUP_30 |
| 0x22 |
SVK_BACKUP_31 |
| 0x23 |
SVK_BACKUP_32 |
| 0x24 |
SVK_BACKUP_33 |
| 0x25 |
SVK_BACKUP_34 |
| 0x26 |
SVK_BACKUP_35 |
| 0x27 |
SVK_BACKUP_36 |
| 0x28 |
SVK_BACKUP_37 |
| 0x29 |
SVK_BACKUP_38 |
| 0x2A |
SVK_BACKUP_39 |
| 0x2B |
SVK_BACKUP_40 |
| 0x2C |
SVK_BACKUP_41 |
| 0x2D |
SVK_BACKUP_42 |
| 0x2E |
SVK_BACKUP_43 |
| 0x2F |
SVK_BACKUP_44 |
| 0x30 |
SVK_BACKUP_45 |
| 0x31 |
SVK_BACKUP_46 |
| 0x32 |
SVK_BACKUP_47 |
| 0x33 |
SVK_BACKUP_48 |
| 0x34 |
SVK_BACKUP_49 |
| 0x35 |
SVK_BACKUP_50 |
| 0x36 |
SVK_BACKUP_51 |
| 0x37 |
SVK_BACKUP_52 |
| 0x38 |
SVK_BACKUP_53 |
| 0x39 |
SVK_BACKUP_54 |
| 0x3A |
SVK_BACKUP_55 |
| 0x3B |
SVK_BACKUP_56 |
| 0x3C |
SVK_BACKUP_57 |
| 0x3D |
SVK_BACKUP_58 |
| 0x3E |
SVK_BACKUP_59 |
| 0x3F |
SVK_BACKUP_60 |
| 0x40 |
SVK_BACKUP_61 |
| 0xXY |
ERROR_UNKNOWN |
DTCEXTENDEDDATARECORDNUMBER
Dimensions: 5 rows × 3 columns
| WERT |
TEXT |
ANZ_BYTE |
| 0x00 |
ISO_RESERVED |
0 |
| 0x01 |
CONDITION_BYTE |
1 |
| 0x02 |
HFK |
1 |
| 0x03 |
HLZ |
1 |
| 0xFF |
RECORD_UNKNOWN |
0 |
DTCSNAPSHOTIDENTIFIER
Dimensions: 7 rows × 9 columns
| UWNR |
UWTEXT |
UW_EINH |
L/H |
UWTYP |
NAME |
MUL |
DIV |
ADD |
| 0x1700 |
KM_STAND |
0-n |
- |
0xFFFFFF |
- |
1 |
1 |
0.000000 |
| 0x1701 |
ABS_ZEIT |
0-n |
- |
0xFFFFFFFF |
- |
1 |
1 |
0.000000 |
| 0x1702 |
SAE_CODE |
0-n |
- |
0xFFFFFF |
- |
1 |
1 |
0.000000 |
| 0x1731 |
Fehlerklasse_DTC |
- |
- |
u char |
- |
1 |
1 |
0.000000 |
| 0x1750 |
PWF_Basinetz |
0-n |
- |
0xFF |
- |
1 |
1 |
0.000000 |
| 0x1751 |
PWF_Teilnetz |
0-n |
- |
0xFFFFFF |
- |
1 |
1 |
0.000000 |
| 0xFFFF |
IDENTIFIER_UNKNOWN |
- |
- |
0xFFFFFF |
- |
1 |
1 |
0.000000 |
FEHLERKLASSE
Dimensions: 5 rows × 2 columns
| NR |
TEXT |
| 0x00 |
Keine Fehlerklasse verfuegbar |
| 0x01 |
Ueberpruefung bei naechstem Werkstattbesuch |
| 0x02 |
Ueberpruefung bei naechstem Halt |
| 0x04 |
Ueberpruefung sofort erforderlich ! |
| 0xFF |
unbekannte Fehlerklasse |
DIAGMODE
Dimensions: 14 rows × 3 columns
| NR |
MODE |
MODE_TEXT |
| 0x00 |
UNGUELTIG |
DefaultMode |
| 0x01 |
DEFAULT |
DefaultMode |
| 0x02 |
ECUPM |
ECUProgrammingMode |
| 0x03 |
ECUEXTDIAG |
ECUExtendedDiagnosticSession |
| 0x04 |
ECUSSDS |
ECUSafetySystemDiagnosticSession |
| 0x40 |
ECUEOL |
ECUEndOfLineSession |
| 0x41 |
ECUCODE |
ECUCodingSession |
| 0x42 |
ECUSWT |
ECUSwtSession |
| 0x43 |
ECUHDD |
ECUHDDDownloadSession |
| 0x44 |
ECURSU |
ECURsuSession |
| 0x4F |
ECUDEVELOP |
ECUDevelopmentSession |
| 0x5F |
ECUGDM |
ECUGarageDiagnoseMode |
| 0x61 |
ECUSUPSPEC |
ECUSupplierSpecificSession |
| 0xXY |
-- |
unbekannter Diagnose-Mode |
IARTTEXTE
Dimensions: 35 rows × 2 columns
| ARTNR |
ARTTEXT |
| 0x00 |
keine Fehlerart verfügbar |
| 0x04 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x05 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x08 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x09 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x0C |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x0D |
Fehler momentan vorhanden und bereits gespeichert |
| 0x20 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x21 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x24 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x25 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x28 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x29 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x2C |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x2D |
Fehler momentan vorhanden und bereits gespeichert |
| 0x40 |
unbekannte Fehlerart |
| 0x44 |
Fehler gespeichert |
| 0x45 |
Fehler gespeichert |
| 0x48 |
Fehler gespeichert |
| 0x49 |
Fehler gespeichert |
| 0x4C |
Fehler gespeichert |
| 0x4D |
Fehler gespeichert |
| 0x60 |
Fehler gespeichert |
| 0x61 |
Fehler gespeichert |
| 0x64 |
Fehler gespeichert |
| 0x65 |
Fehler gespeichert |
| 0x68 |
Fehler gespeichert |
| 0x69 |
Fehler gespeichert |
| 0x6C |
Fehler gespeichert |
| 0x6D |
Fehler gespeichert |
| 0x10 |
Testbedingungen erfüllt |
| 0x11 |
Testbedingungen noch nicht erfüllt |
| 0x80 |
Fehler würde kein Aufleuchten einer Warnlampe verursachen |
| 0x81 |
Fehler würde das Aufleuchten einer Warnlampe verursachen |
| 0xFF |
unbekannte Fehlerart |
UDS_TAB_ROE_AKTIV
Dimensions: 3 rows × 2 columns
| NR |
TEXT |
| 0x00 |
Aktive Fehlermeldung deaktiviert |
| 0x01 |
Aktive Fehlermeldung aktiviert |
| 0xFF |
Status der aktiven Fehlermeldung nicht feststellbar |
ARG_0X4000_D
Dimensions: 1 rows × 12 columns
| ARG |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| PIN |
Byte |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
1000.0 |
9999.0 |
PIN für Authentisierung |
ARG_0X4001_D
Dimensions: 13 rows × 12 columns
| ARG |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| PIN |
Byte |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
1000.0 |
9999.0 |
PIN für Authentisierung |
| LAMP_SUPPLIER |
TEXT |
high |
string[6] |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Name of the Lamp Supplier |
| SUPPLIER_PLANT |
TEXT |
high |
string[6] |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Assembly plant of the rear lamp |
| PRODUCTION_DATE |
- |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Production date of the rear lamp. Format: YYYYMMDD |
| SERIAL_NUMBER |
TEXT |
high |
string[16] |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Serial Number of the lamp |
| LED_TYPE_CHANEL_1 |
TEXT |
high |
string[10] |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
OLED/LED Supplier and LED Type |
| LED_TYPE_CHANEL_2 |
TEXT |
high |
string[10] |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
LED Supplier and LED Type |
| LED_TYPE_CHANEL_3 |
TEXT |
high |
string[10] |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
LED Supplier and LED Type |
| LED_TYPE_CHANEL_4 |
TEXT |
high |
string[10] |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
LED Supplier and LED Type |
| LED_TYPE_CHANEL_5 |
TEXT |
high |
string[10] |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
LED Supplier and LED Type |
| LED_TYPE_CHANEL_6 |
TEXT |
high |
string[10] |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
LED Supplier and LED Type |
| LED_TYPE_CHANEL_7 |
TEXT |
high |
string[10] |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
LED Supplier and LED Type |
| HARDWARE_VARIANT |
0-n |
high |
unsigned char |
- |
TAB_HARDWARE_VARIANT |
- |
- |
- |
- |
- |
SAE/ECE value |
ARG_0X4002_D
Dimensions: 9 rows × 12 columns
| ARG |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| PIN |
Byte |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
1000.0 |
9999.0 |
PIN für Authentisierung |
| CHANNEL_1 |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Binning class for channel 1 |
| CHANNEL_2 |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Binning class for channel 2 |
| CHANNEL_3 |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Binning class for channel 3 |
| CHANNEL_4 |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Binning class for channel 4 |
| CHANNEL_5 |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Binning class for channel 5 |
| CHANNEL_6 |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Binning class for channel 6 |
| CHANNEL_7 |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Binning class for channel 7 |
| DUMMY |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
reserved |
ARG_0X4061_D
Dimensions: 1 rows × 12 columns
| ARG |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| PIN |
Byte |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
1000.0 |
9999.0 |
PIN für Authentisierung |
ARG_0X4062_D
Dimensions: 1 rows × 12 columns
| ARG |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| PIN |
Byte |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
1000.0 |
9999.0 |
PIN für Authentisierung |
ARG_0XD6DA_D
Dimensions: 3 rows × 12 columns
| ARG |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| KANAL |
0-n |
high |
unsigned char |
- |
KANAL_RLM |
- |
- |
- |
- |
- |
Auswahl des RLM Kanal |
| ZEIT |
s |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
255.0 |
Zeitvorgabe in Sekunden (0=aus ... 254 s, 255 = dauerhaft ein) |
| PWM |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
PWM Wert 0...100% |
ARG_0XD6DD_D
Dimensions: 2 rows × 12 columns
| ARG |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| ELEMENT |
0-n |
- |
signed int |
- |
TAB_RUECKLEUCHTEN_FUNKTION_ARG |
- |
- |
- |
- |
- |
Auswahl siehe table TAB_RUECKLEUCHTEN_FUNKTION_ARG |
| ZEIT |
s |
- |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Zeitvorgabe [0..255] in Sekunden, 0=aus ...254, 255=permanent an. |
ARG_0XF002_R
Dimensions: 1 rows × 14 columns
| ARG |
STR |
STPR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| KANAL_NR |
+ |
- |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
1.0 |
8.0 |
Kanalnummerl [1..8] |
ARG_0XF003_R
Dimensions: 1 rows × 14 columns
| ARG |
STR |
STPR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| KANAL_NR |
+ |
- |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
Lese Voltagestatistik pro Kanal [1..7] |
ARG_0XF100_R
Dimensions: 36 rows × 14 columns
| ARG |
STR |
STPR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| STAT_01_LED_1_STROM_WERT |
+ |
- |
mA |
high |
unsigned char |
- |
- |
1.0 |
10.0 |
0.0 |
0.0 |
1500.0 |
Stromwert LED 1 |
| STAT_02_STRANG_1_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert Strang 1 |
| STAT_03_LED_1_1_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 11 |
| STAT_04_LED_1_2_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 12 |
| STAT_05_LED_1_3_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 13 |
| STAT_06_LED_2_STROM_WERT |
+ |
- |
mA |
high |
unsigned char |
- |
- |
1.0 |
10.0 |
0.0 |
0.0 |
1500.0 |
Stromwert LED 2 |
| STAT_07_STRANG_2_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert Strang 2 |
| STAT_08_LED_2_1_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 21 |
| STAT_09_LED_2_2_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 22 |
| STAT_10_LED_2_3_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 23 |
| STAT_11_LED_3_STROM_WERT |
+ |
- |
mA |
high |
unsigned char |
- |
- |
1.0 |
10.0 |
0.0 |
0.0 |
1500.0 |
Stromwert LED 3 |
| STAT_12_STRANG_3_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert Strang 3 |
| STAT_13_LED_3_1_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 31 |
| STAT_14_LED_3_2_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 32 |
| STAT_15_LED_3_3_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 33 |
| STAT_16_LED_4_STROM_WERT |
+ |
- |
mA |
high |
unsigned char |
- |
- |
1.0 |
10.0 |
0.0 |
0.0 |
1500.0 |
Stromwert LED 4 |
| STAT_17_STRANG_4_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert Strang 4 |
| STAT_18_LED_4_1_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 41 |
| STAT_19_LED_4_2_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 42 |
| STAT_20_LED_4_3_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 43 |
| STAT_21_LED_5_STROM_WERT |
+ |
- |
mA |
high |
unsigned char |
- |
- |
1.0 |
10.0 |
0.0 |
0.0 |
1500.0 |
Stromwert LED 5 |
| STAT_22_STRANG_5_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert Strang 5 |
| STAT_23_LED_5_1_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 51 |
| STAT_24_LED_5_2_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 52 |
| STAT_25_LED_6_STROM_WERT |
+ |
- |
mA |
high |
unsigned char |
- |
- |
1.0 |
10.0 |
0.0 |
0.0 |
1500.0 |
Stromwert LED 6 |
| STAT_26_STRANG_6_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert Strang 6 |
| STAT_27_LED_6_1_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 61 |
| STAT_28_LED_6_2_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 62 |
| STAT_29_LED_6_3_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 63 |
| STAT_30_LED_6_4_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 64 |
| STAT_31_LED_6_5_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 65 |
| STAT_32_LED_6_6_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 66 |
| STAT_33_LED_7_STROM_WERT |
+ |
- |
mA |
high |
unsigned char |
- |
- |
1.0 |
10.0 |
0.0 |
0.0 |
1500.0 |
Stromwert LED 7 |
| STAT_34_LED_7_1_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 71 |
| STAT_35_LED_8_STROM_WERT |
+ |
- |
mA |
high |
unsigned char |
- |
- |
1.0 |
10.0 |
0.0 |
0.0 |
1500.0 |
Stromwert LED 8 |
| STAT_36_LED_8_1_PWM_WERT |
+ |
- |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
100.0 |
Prozent Wert LED 81 |
ARG_0XFD00_D
Dimensions: 1 rows × 12 columns
| ARG |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| RESET_ZAEHLER_LOESCHEN |
0-n |
high |
unsigned int |
- |
TAB_RESET_ZAEHLER_LOESCHEN |
- |
- |
- |
- |
- |
Ruecksetzen des Reset oder Watchdog Zaehlers |
ARG_0XFD01_D
Dimensions: 1 rows × 12 columns
| ARG |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| RESET_BULB_OP_TIME |
0-n |
high |
unsigned int |
- |
TAB_BULB_OP_TIME_RESET |
- |
- |
- |
- |
- |
Reset Bulb operation time for segments |
ARG_0XFD02_D
Dimensions: 1 rows × 12 columns
| ARG |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| RESET_STATISTIC_TEMPERATUR_HISTOGRAMM_CHANNEL |
HEX |
high |
unsigned char |
- |
- |
- |
- |
- |
- |
- |
Kanal [1..8] |
ARG_0XFD03_D
Dimensions: 1 rows × 12 columns
| ARG |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| RESET_STATISTIC_VOLTAGE_HISTOGRAM_CHANNEL |
HEX |
high |
unsigned char |
- |
- |
- |
- |
- |
- |
- |
Rücksetzten der Voltage Staistic Daten für einen Kanal [1..7] |
ARG_0XFD04_D
Dimensions: 1 rows × 12 columns
| ARG |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| SELECT |
HEX |
high |
unsigned char |
- |
- |
- |
- |
- |
- |
- |
Index 0: all |
BF_22_F152_SUPPLIERINFO
Dimensions: 2 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_HWMODEL |
0-n |
high |
unsigned char |
0xC0 |
HW_MODEL |
- |
- |
- |
hardware model |
| STAT_SUPPLIERINFOFIELD |
0-n |
high |
unsigned char |
0x3F |
TAB_SUPPLIERINFO_FIELD |
- |
- |
- |
supplierInfo |
BETRIEBSMODE
Dimensions: 6 rows × 3 columns
| WERT |
TEXT |
BEDEUTUNG |
| 0x00 |
Allgemeiner Fertigungs- und Energiesparmode |
Hier deaktivierte Funktionen gemäß FeTra-Liste festhalten |
| 0x01 |
Spezieller Energiesparmode |
- |
| 0x02 |
ECOS-Mode |
- |
| 0x03 |
MOST-Mode |
- |
| 0x04 |
Rollenmode |
- |
| 0xFF |
ungültiger Betriebsmode |
ungültig |
FDETAILSTRUKTUR
Dimensions: 6 rows × 2 columns
| NAME |
TYP |
| F_UWB_ERW |
ja |
| SAE_CODE |
nein |
| F_HLZ |
nein |
| F_SEVERITY |
nein |
| F_UWB_SATZ |
2 |
| F_HLZ_VIEW |
nein |
FORTTEXTE
Dimensions: 66 rows × 4 columns
| ORT |
ORTTEXT |
EREIGNIS_DTC |
FEHLERKLASSE |
| 0x021C00 |
Energiesparmode aktiv |
0 |
- |
| 0x021C08 |
Codierung: Steuergerät ist nicht codiert |
0 |
- |
| 0x021C09 |
Codierung: Fehler bei Codierdatentransaktion aufgetreten |
0 |
- |
| 0x021C0A |
Codierung: Signatur der Codierdaten ungültig |
0 |
- |
| 0x021C0B |
Codierung: Codierdaten passen nicht zum Fahrzeug |
0 |
- |
| 0x021C0C |
Codierung: Unplausible Daten während Codierdatentransaktion |
0 |
- |
| 0x021C0D |
Codierung: unqualifizierte Daten |
0 |
- |
| 0x021C24 |
NVM_E_HARDWARE |
0 |
- |
| 0x02FF1C |
Dummy-Fehlerspeichereintrag im Komponentenfehlerbereich nur für Testzwecke |
1 |
- |
| 0x808300 |
Unterspannung erkannt |
1 |
- |
| 0x808301 |
Überspannung erkannt |
1 |
- |
| 0x808302 |
Überfallalarm: defekt |
0 |
- |
| 0x808303 |
Fernlichtblinken: defekt |
0 |
- |
| 0x808304 |
Panik Blinken: defekt |
0 |
- |
| 0x808305 |
DWA Blinken: defekt |
0 |
- |
| 0x808306 |
ESS Blinken: defekt |
0 |
- |
| 0x808307 |
Standlicht: defekt |
0 |
- |
| 0x808308 |
Follow Me Home: defekt |
0 |
- |
| 0x808309 |
Welcome Light: defekt |
0 |
- |
| 0x80830A |
Remote Light: defekt |
0 |
- |
| 0x80830B |
Goodbye Bremslicht: defekt |
0 |
- |
| 0x80830C |
Ausgelagerte Leuchte: defekt |
0 |
- |
| 0x80830D |
Fahrtrichtungsanzeiger: defekt |
0 |
- |
| 0x80830E |
Tagfahrlicht: defekt |
0 |
- |
| 0x80830F |
Seitenmarkierungsleuchte: defekt |
0 |
- |
| 0x808310 |
Parklicht: defekt |
0 |
- |
| 0x808311 |
Bremslicht: defekt |
0 |
- |
| 0x808312 |
Nebelschlusslicht: defekt |
0 |
- |
| 0x808313 |
Rueckfahrlicht: defekt |
0 |
- |
| 0x808314 |
Bremslicht - Notlaufaktivierung wegen unplausibler Eingangssignale |
1 |
- |
| 0x80831E |
CAN_TIMEOUT_ERROR |
0 |
- |
| 0x80831F |
MCAL_PORT_TIMEOUT_ERROR |
0 |
- |
| 0x808320 |
FLS_Error |
0 |
- |
| 0x808328 |
GPT_ERROR |
0 |
- |
| 0x808329 |
MCU_ERROR |
0 |
- |
| 0x80832A |
WDG_ERROR |
0 |
- |
| 0x80832B |
WDGM_ERROR |
0 |
- |
| 0x808343 |
Variant not configured |
0 |
- |
| 0x808344 |
configuration data invalid combined event |
0 |
- |
| 0x808360 |
NTC1: Temperatursensor on board |
0 |
- |
| 0x808361 |
NTC2: Temperatursensor combinded event |
0 |
- |
| 0x808362 |
NTC3: Temperatursensor combinded event |
0 |
- |
| 0x808363 |
NTC4: Temperatursensor combinded event |
0 |
- |
| 0xD0050B |
B2-CAN Physikalischer Busfehler |
0 |
- |
| 0xD00514 |
B2-CAN Control Module Bus OFF |
0 |
- |
| 0xD00B00 |
Botschaft 0x2EB (CTR_LP_EX) - Timeout combined event |
1 |
- |
| 0xD00B01 |
Botschaft 0x2EB (CTR_LP_EX) - Alive/CRC |
1 |
- |
| 0xD00B03 |
Botschaft 0x1E4 (CTR_LP_EX_2) - Timeout combined event |
1 |
- |
| 0xD00B09 |
Botschaft 0x2CA (A_Temp)- Timeout combined event |
1 |
- |
| 0xD00B0F |
Botschaft 0xCA (CTR_FN_IDC) - Timeout combined event |
1 |
- |
| 0xD00B10 |
Botschaft 0xCA (CTR_FN_IDC) - Alive/CRC |
1 |
- |
| 0xD00B12 |
Botschaft 0x328 (Relativzeit) - Timeout combined event |
1 |
- |
| 0xD00B15 |
Botschaft 0x32 (ST_CENG) - Timeout combined event |
1 |
- |
| 0xD00B18 |
Botschaft 0x1A1 (V_VEH) - Timeout combined event |
1 |
- |
| 0xD00B19 |
Botschaft 0x1A1 (V_VEH) - Alive/CRC |
1 |
- |
| 0xD00B1B |
Botschaft 0x21x (ST_LP_EX_REAR_SAME_SIDE) - Timeout combined event |
1 |
- |
| 0xD00B1C |
Botschaft 0x21x (ST_LP_EX_REAR_SAME_SIDE) - Alive/CRC combined event |
1 |
- |
| 0xD00B25 |
Botschaft 0x21x (ST_LP_EX_REAR_OTHER_SIDE_MASTER_1) - Timeout combined event |
1 |
- |
| 0xD00B26 |
Botschaft 0x21x (ST_LP_EX_REAR_OTHER_SIDE_MASTER_1) - Alive/CRC |
1 |
- |
| 0xD00B28 |
Botschaft 0x21x (ST_LP_EX_REAR_OTHER_SIDE_SLAVE_2) - Timeout combined event |
1 |
- |
| 0xD00B29 |
Botschaft 0x21x (ST_LP_EX_REAR_OTHER_SIDE_SLAVE_2) - Alive/CRC |
1 |
- |
| 0xD00B2B |
Botschaft 0x3C (Con_VEH) - Timeout combined event |
1 |
- |
| 0xD00B2C |
Botschaft 0x3C (Con_VEH) - Alive/CRC |
1 |
- |
| 0xD00B2E |
Botschaft 0x2FC (STAT_ZV_KLAPPEN) - Timeout combined event |
1 |
- |
| 0xD00BFF |
Dummy-Fehlerspeichereintrag im Netzwerkfehlerbereich nur für Testzwecke |
1 |
- |
| 0xFFFFFF |
unbekannter Fehlerort |
0 |
- |
FSCSM_ERRORCODE_TAB
Dimensions: 18 rows × 2 columns
| WERT |
TEXT |
| 0x01 |
ERC_FSCSM_INVALID_ENCRYPTED_ID_AND_KEY |
| 0x02 |
ERC_FSCSM_INVALID_SG_ID |
| 0x04 |
ERC_FSCSM_SWE_INVALID |
| 0x05 |
ERC_FSCSM_CAL_CSM_ERROR |
| 0x06 |
ERC_FSCSM_SSV_ERROR_STATE |
| 0x08 |
ERC_FSCSM_MESSAGE_TIMEOUT_REQ |
| 0x00 |
ERC_NO_ERROR |
| 0x30 |
ERC_PENDING |
| 0x50 |
ERC_NVM_ERROR |
| 0x51 |
ERC_INCORRECT_MESSAGE_LENGTH |
| 0x52 |
ERC_INVALID_PARAMETER |
| 0x53 |
ERC_SEQUENCE_ERROR |
| 0x54 |
ERC_NOT_INITIALIZED |
| 0x55 |
ERC_PARALLEL_EXECUTION |
| 0x87 |
ERC_MSM_INVALID_SIGNATURE_OVER_RND |
| 0x88 |
ERC_MSM_INVALID_B2VSEC_CERTIFICATE |
| 0x5A |
ERC_CALCULATION_ERROR |
| 0xFE |
ERC_UNEXPECTED_ERROR |
FUMWELTTEXTE
Dimensions: 92 rows × 9 columns
| UWNR |
UWTEXT |
UW_EINH |
L/H |
UWTYP |
NAME |
MUL |
DIV |
ADD |
| 0x1700 |
Kilometerstand |
TEXT |
High |
3 |
- |
- |
- |
- |
| 0x1701 |
Systemzeit |
s |
High |
signed long |
- |
1.0 |
1.0 |
0.0 |
| 0x1742 |
SWT_FEHLERWERT |
HEX |
High |
unsigned char |
- |
- |
- |
- |
| 0x1743 |
SWT_VIN |
TEXT |
High |
7 |
- |
1.0 |
1.0 |
0.0 |
| 0x1744 |
SWT_ID |
HEX |
High |
signed long |
- |
- |
- |
- |
| 0x1750 |
F_UW_BN |
- |
High |
signed char |
- |
1.0 |
1.0 |
0.0 |
| 0x1751 |
F_UW_TN |
TEXT |
High |
3 |
- |
1.0 |
1.0 |
0.0 |
| 0x1760 |
FSCSM_ERRORCODE |
0-n |
High |
0xFF |
FSCSM_ERRORCODE_TAB |
- |
- |
- |
| 0x4006 |
UWB_DEFEKT_ART_STRANG_LED1 |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_STRANG |
- |
- |
- |
| 0x4007 |
UWB_DEFEKT_ART_NTC |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_NTC |
- |
- |
- |
| 0x4008 |
Außentemperatur |
°C |
High |
unsigned char |
- |
0.5 |
1.0 |
-40.0 |
| 0x4009 |
Fahrzeuggeschwindigkeit |
km/h |
High |
unsigned int |
- |
0.015625 |
1.0 |
0.0 |
| 0x400A |
KLEMMENZUSTAND_PWF |
- |
High |
unsigned int |
- |
1.0 |
1.0 |
0.0 |
| 0x400B |
UWB Bordnetzspannung SysVolt |
V |
High |
unsigned char |
- |
0.1 |
1.0 |
0.0 |
| 0x400C |
UWB Signalname_0x2EB_CTRL_LP_EX |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X2CB_CTRL_LP_EX |
- |
- |
- |
| 0x400D |
UWB Timeout Botschaft 0x2EB CTR_LP_EX |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0x2EB_CTR_LP_EX |
- |
- |
- |
| 0x400E |
UWB_ALIVE_CRC_0x2EB_CTR_LP_EX |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X2EB_CTR_LP_EX |
- |
- |
- |
| 0x400F |
FLS_ERROR_SOURCE |
0-n |
High |
0xFF |
UWB_TAB_FLS_ERROR_SOURCE |
- |
- |
- |
| 0x4010 |
GPT_ERROR_SOURCE |
0-n |
High |
0xFF |
UWB_TAB_GPT_ERROR_SOURCE |
- |
- |
- |
| 0x4011 |
MCU_ERROR_SOURCE |
0-n |
High |
0xFF |
UWB_TAB_MCU_ERROR_SOURCE |
- |
- |
- |
| 0x4012 |
NVM_ERROR_SOURCE |
0-n |
High |
0xFF |
UWB_TAB_NVM_ERROR_SOURCE |
- |
- |
- |
| 0x4013 |
WDG_ERROR_SOURCE |
0-n |
High |
0xFF |
UWB_TAB_WDG_ERROR_SOURCE |
- |
- |
- |
| 0x4014 |
WDGM_ERROR_SOURCE |
0-n |
High |
0xFF |
UWB_TAB_WDGM_ERROR_SOURCE |
- |
- |
- |
| 0x4015 |
UWB Signal_0x1E4_error_source |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X1E4_CTR_LP_EX_2 |
- |
- |
- |
| 0x4016 |
UWB Timeout source of message 0X1E4_CTR_LP_EX_2 |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X1E4_CTR_LP_EX_2 |
- |
- |
- |
| 0x4018 |
UWB ALIVE_CRC_ERROR_CTR_LP_EX_2 |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X1E4_CTR_LP_EX_2 |
- |
- |
- |
| 0x4019 |
UWB SIGNAL_0X330_KILOMETERSTAND |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0x330_Kilometerstand |
- |
- |
- |
| 0x401A |
UWB Timeout_0X330_Kiliometerstand |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X330_KILOMETERSTAND |
- |
- |
- |
| 0x401B |
UWB_ALIVE_CRC_0X330_KILOMETERSTAND |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X330_KILOMETERSTAND |
- |
- |
- |
| 0x401C |
UWB SIGNAL_0X2CA_A_TEMP |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0x2CA_A_TEMP |
- |
- |
- |
| 0x401D |
UWB Timeout_0X2CA_A_TEMP |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0x2CA_A_Temp |
- |
- |
- |
| 0x401E |
UWB_ALIVE_CRC_0x2CA_A_TEMP |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0x2CA_A_Temp |
- |
- |
- |
| 0x401F |
UWB_SIGNAL_0x380_Fahrgestellnummer |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0x380_Fahrgestellnummer |
- |
- |
- |
| 0x4020 |
UWB_TIMEOUT_0X380_FAHRGESTELLNUMMER |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X380_FAHRGESTELLNUMMER |
- |
- |
- |
| 0x4021 |
UWB_ALIVE_CRC_0X380_FAHRGESTELLNUMMER |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X380_FAHRGESTELLNUMMER |
- |
- |
- |
| 0x4022 |
UWB_SIGNAL_0XCA_CTR_FN_IDC |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0XCA_CTR_FN_IDC |
- |
- |
- |
| 0x4023 |
UWB_TIMEOUT_0XCA_CTR_FN_IDC |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_CRC_0XCA_CTR_FN_IDC |
- |
- |
- |
| 0x4024 |
UWB_ALIVE_CRC_0XCA_CTR_FN_IDC |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0XCA_CTR_FN_IDC |
- |
- |
- |
| 0x4025 |
UWB_SIGNAL_0X328_RELATIVZEIT |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X328_RELATIVZEIT |
- |
- |
- |
| 0x4026 |
UWB_TIMEOUT_0X328_RELATIVZEIT |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X328_RELATIVZEIT |
- |
- |
- |
| 0x4027 |
UWB_ALIVE_CRC_0X328_RELATIVZEIT |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X328_RELATIVZEIT |
- |
- |
- |
| 0x4028 |
UWB_SIGNAL_0X32_ST_CENG |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X32_ST_CENG |
- |
- |
- |
| 0x4029 |
UWB_TIMEOUT_0X32_ST_CENG |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X32_ST_CENG |
- |
- |
- |
| 0x402A |
UWB_ALIVE_CRC__0X32_ST_CENG |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X32_ST_CENG |
- |
- |
- |
| 0x402B |
UWB_SIGNAL_0X1A1_V_VEH |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X1A1_V_VEH |
- |
- |
- |
| 0x402C |
UWB_TIMEOUT_0X1A1_V_VEH |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X1A1_V_VEH |
- |
- |
- |
| 0x402D |
UWB_ALIVE_CRC_0X1A1_V_VEH |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X1A1_V_VEH |
- |
- |
- |
| 0x402E |
UWB_SIGNAL_0X215_ST_LP_EX_REAR_SAME_SIDE |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X215_REAR_2 |
- |
- |
- |
| 0x402F |
UWB_TIMEOUT_0X215_ST_LP_EX_REAR_SAME_SIDE |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X215_ST_LP_EX_REAR |
- |
- |
- |
| 0x4030 |
UWB_ALIVE_CRC_0X215_ST_LP_EX_REAR_SAME_SIDE |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X215_ST_LP_EX_REAR |
- |
- |
- |
| 0x4031 |
UWB_SIGNAL_0X388_FAHRZEUGTYP |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X388_FAHRZEUGTYP |
- |
- |
- |
| 0x4032 |
UWB_TIMEOUT_0X388_FAHRZEUGTYP |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X388_FAHRZEUGTYP |
- |
- |
- |
| 0x4033 |
UWB_ALIVE_CRC_0X388_FAHRZEUGTYP |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X388_FAHRZEUGTYP |
- |
- |
- |
| 0x4034 |
UWB_SIGNAL_0X3A0_FZZSTD |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X3A0_FZZSTD |
- |
- |
- |
| 0x4035 |
UWB_TIMEOUT_0X3A0_FZZSTD |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X3A0_FZZSTD |
- |
- |
- |
| 0x4036 |
UWB_ALIVE_CRC_0X3A0_FZZSTD |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X3A0_FZZSTD |
- |
- |
- |
| 0x4039 |
UWB_OVERVOLTAGE_SEG_STRANG_1 |
0-n |
High |
0xFF |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_1 |
- |
- |
- |
| 0x403A |
UWB_OVERVOLTAGE_SEG_STRANG_2 |
0-n |
High |
0xFF |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_2 |
- |
- |
- |
| 0x403B |
UWB_OVERVOLTAGE_SEG_STRANG_3 |
0-n |
High |
0xFF |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_3 |
- |
- |
- |
| 0x403C |
UWB_OVERVOLTAGE_SEG_STRANG_4 |
0-n |
High |
0xFF |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_4 |
- |
- |
- |
| 0x403D |
UWB_OVERVOLTAGE_SEG_STRANG_5 |
0-n |
High |
0xFF |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_5 |
- |
- |
- |
| 0x403E |
UWB_OVERVOLTAGE_SEG_STRANG_6 |
0-n |
High |
0xFF |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_6 |
- |
- |
- |
| 0x403F |
UWB_UNDERVOLTAGE_SEG_STRANG_1 |
0-n |
High |
0xFF |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_1 |
- |
- |
- |
| 0x4040 |
UWB_UNDERVOLTAGE_SEG_STRANG_2 |
0-n |
High |
0xFF |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_2 |
- |
- |
- |
| 0x4041 |
UWB_UNDERVOLTAGE_SEG_STRANG_3 |
0-n |
High |
0xFF |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_3 |
- |
- |
- |
| 0x4042 |
UWB_UNDERVOLTAGE_SEG_STRANG_4 |
0-n |
High |
0xFF |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_4 |
- |
- |
- |
| 0x4043 |
UWB_UNDERVOLTAGE_SEG_STRANG_5 |
0-n |
High |
0xFF |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_5 |
- |
- |
- |
| 0x4044 |
UWB_UNDERVOLTAGE_SEG_STRANG_6 |
0-n |
High |
0xFF |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_6 |
- |
- |
- |
| 0x4045 |
UWB_SIGNAL_0X215_ST_LP_EX_REAR_OTHER_SIDE_MASTER_1 |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X215_REAR_2 |
- |
- |
- |
| 0x4046 |
UWB_TIMEOUT_0X215_ST_LP_EX_REAR_OTHER_SIDE_MASTER_1 |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X215_ST_LP_EX_REAR |
- |
- |
- |
| 0x4047 |
UWB_ALIVE_CRC_0X215_ST_LP_EX_REAR_OTHER_SIDE_MASTER_1 |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X215_ST_LP_EX_REAR |
- |
- |
- |
| 0x4048 |
UWB_SIGNAL_0X215_ST_LP_EX_REAR_OTHER_SIDE_SLAVE_2 |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X215_REAR_2 |
- |
- |
- |
| 0x4049 |
UWB_TIMEOUT_0X215_ST_LP_EX_REAR_OTHER_SIDE_SLAVE_2 |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X215_ST_LP_EX_REAR |
- |
- |
- |
| 0x404A |
UWB_ALIVE_CRC_0X215_ST_LP_EX_REAR_OTHER_SIDE_SLAVE_2 |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X215_ST_LP_EX_REAR |
- |
- |
- |
| 0x404B |
UWB_TIMEOUT_0X3C_CON_VEH |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X3C_CON_VEH |
- |
- |
- |
| 0x404C |
UWB_ALIVE_CRC_0X3C_Con_VEH |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X3C_CON_VEH |
- |
- |
- |
| 0x404D |
UWB_SIGNAL_0X3C_Con_VEH |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X3C_Con_VEH |
- |
- |
- |
| 0x404E |
UWB_TIMEOUT_0X2FC_STAT_ZV_KLAPPEN |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0x2FC_STAT_ZV_KLAPPEN |
- |
- |
- |
| 0x404F |
UWB_DEFEKT_ART_STRANG_LED2 |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_STRANG |
- |
- |
- |
| 0x4050 |
UWB_DEFEKT_ART_STRANG_LED3 |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_STRANG |
- |
- |
- |
| 0x4051 |
UWB_DEFEKT_ART_STRANGLED4 |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_STRANG |
- |
- |
- |
| 0x4052 |
UWB_DEFEKT_ART_STRANG_LED5 |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_STRANG |
- |
- |
- |
| 0x4053 |
UWB_DEFEKT_ART_STRANG_LED6 |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_STRANG |
- |
- |
- |
| 0x4054 |
UWB_DEFEKT_ART_STRANG_LED7 |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_STRANG |
- |
- |
- |
| 0x4055 |
UWB_DEFEKT_ART_NTC |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_NTC |
- |
- |
- |
| 0x4056 |
UWB_DEFEKT_ART_NTC |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_NTC |
- |
- |
- |
| 0x4057 |
UWB_DEFEKT_ART_NTC |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_NTC |
- |
- |
- |
| 0x4058 |
UWB_DEFEKT_ART_NTC |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_NTC |
- |
- |
- |
| 0x4059 |
UWB_DEFEKT_ART_STRANG_HSS |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_STRANG |
- |
- |
- |
| 0x405A |
UWB_CONFIGURATION_DATA_INVALID |
0-n |
High |
0xFF |
UWB_TAB_CONFIGURATION_DATA_INVALID |
- |
- |
- |
| 0x405B |
UWB_DEFEKT_ART_NOTLAUFAKTIVIERUNG |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_NOTLAUFAKTIVIERUNG |
- |
- |
- |
| 0xXYXY |
unbekannte Umweltbedingung |
- |
- |
- |
- |
- |
- |
- |
HW_MODEL
Dimensions: 5 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
A-Muster |
| 0x40 |
B-Muster |
| 0x80 |
C-Muster |
| 0xC0 |
D-Muster |
| 0xFF |
Wert ungültig |
IDETAILSTRUKTUR
Dimensions: 5 rows × 2 columns
| NAME |
TYP |
| F_UWB_ERW |
ja |
| SAE_CODE |
nein |
| F_HLZ |
nein |
| F_SEVERITY |
nein |
| F_UWB_SATZ |
2 |
IORTTEXTE
Dimensions: 69 rows × 4 columns
| ORT |
ORTTEXT |
EREIGNIS_DTC |
FEHLERKLASSE |
| 0x808321 |
LED Ausgang 1: Strang |
0 |
- |
| 0x808322 |
LED Ausgang 2: Strang |
0 |
- |
| 0x808323 |
LED Ausgang 3: Strang |
0 |
- |
| 0x808324 |
LED Ausgang 4: Strang |
0 |
- |
| 0x808325 |
LED Ausgang 5: Strang |
0 |
- |
| 0x808326 |
LED Ausgang 6: Strang |
0 |
- |
| 0x808327 |
LED Ausgang 7: Strang |
0 |
- |
| 0x80832C |
Overvoltage_Segment_Strang_1: Strang combined event |
0 |
- |
| 0x80832D |
Overvoltage_Segment_Strang_2: Strang combined event |
0 |
- |
| 0x80832E |
Overvoltage_Segment_Strang_3: Strang combined event |
0 |
- |
| 0x80832F |
Overvoltage_Segment_Strang_4: Strang combined event |
0 |
- |
| 0x808330 |
Overvoltage_Segment_Strang_5: Strang combined event |
0 |
- |
| 0x808331 |
Overvoltage_Segment_Strang_6: Strang combined event |
0 |
- |
| 0x808332 |
Undervoltage_Segment_Strang_1: Strang combined event |
0 |
- |
| 0x808333 |
Undervoltage_Segment_Strang_2: Strang combined event |
0 |
- |
| 0x808334 |
Undervoltage_Segment_Strang_3: Strang combined event |
0 |
- |
| 0x808335 |
Undervoltage_Segment_Strang_4: Strang combined event |
0 |
- |
| 0x808336 |
Undervoltage_Segment_Strang_5: Strang combined event |
0 |
- |
| 0x808337 |
Undervoltage_Segment_Strang_6: Strang combined event |
0 |
- |
| 0x808338 |
Overvoltage_Segment_Strang_7 |
0 |
- |
| 0x808339 |
Undervoltage_Segment_Strang_7 |
0 |
- |
| 0x80833A |
CRC-Checksum Fehler |
0 |
- |
| 0x80833B |
Booster defekt |
0 |
- |
| 0x80833C |
ChargePump nicht abschaltbar |
0 |
- |
| 0x80833D |
Überlauf SPI-Empfangspuffer |
0 |
- |
| 0x80833E |
Controller nicht abschaltbar |
0 |
- |
| 0x80833F |
Reset |
0 |
- |
| 0x808340 |
Watchdog hat Reset ausgelöst |
0 |
- |
| 0x808341 |
Fehlerhafter Quarz-Betrieb des Controllers |
0 |
- |
| 0x808342 |
LED Ausgang 8: HSS combined event |
0 |
- |
| 0x808345 |
FLS_E_COMPARE_FAILED |
0 |
- |
| 0x808346 |
FLS_E_ERASE_FAILED |
0 |
- |
| 0x808347 |
FLS_E_READ_FAILED |
0 |
- |
| 0x808348 |
FLS_E_UNEXPECTED_FLASH_ID |
0 |
- |
| 0x808349 |
FLS_E_WRITE_FAILED |
0 |
- |
| 0x80834A |
FLS_E_READ_FAILED_DED |
0 |
- |
| 0x80834B |
MCU_E_WRITE_TIMOUT_FAILURE |
0 |
- |
| 0x80834C |
MCU_E_LVI_FAILURE |
0 |
- |
| 0x80834D |
NVM_E_INTEGRITY_FAILED |
0 |
- |
| 0x80834E |
NVM_E_LOSS_OF_REDUNDANCY |
0 |
- |
| 0x80834F |
NVM_E_QUEUE_OVERFLOW |
0 |
- |
| 0x808350 |
NVM_E_REQ_FAILED |
0 |
- |
| 0x808351 |
NVM_E_VERIFY_FAILED |
0 |
- |
| 0x808352 |
NVM_E_WRITE_PROTECTED |
0 |
- |
| 0x808353 |
NVM_E_WRONG_BLOCK_ID |
0 |
- |
| 0x808354 |
WDG_E_DISABLE_REJECTED |
0 |
- |
| 0x808355 |
WDG_E_MODE_FAILED |
0 |
- |
| 0x808356 |
WDG_E_TRIGGER_TIMEOUT |
0 |
- |
| 0x808357 |
WDG_E_READBACK_FAILURE |
0 |
- |
| 0x808358 |
WDGM_E_IMPROPER_CALLER |
0 |
- |
| 0x808359 |
WDGM_E_MONITORING |
0 |
- |
| 0x80835A |
WDGM_E_SET_MODE |
0 |
- |
| 0xD00B02 |
Botschaft 0x2EB (CTR_LP_EX) - Signal combined event |
1 |
- |
| 0xD00B05 |
Botschaft 0x1E4 (CTR_LP_EX_2) - Signal combined event |
1 |
- |
| 0xD00B08 |
Botschaft 0x330 Kilometerstand- Signal combined event |
1 |
- |
| 0xD00B0B |
Botschaft 0x2CA (A_Temp) - Signal combined event |
1 |
- |
| 0xD00B0E |
Botschaft 0x380 (Fahrgestellnummer) - Signal combined event |
1 |
- |
| 0xD00B11 |
Botschaft 0xCA (CTR_FN_IDC) - Signal combined event |
1 |
- |
| 0xD00B14 |
Botschaft 0x328 (Relativzeit) - Signal combined event |
1 |
- |
| 0xD00B17 |
Botschaft 0x32 (ST_CENG) - Signal combined event |
1 |
- |
| 0xD00B1A |
Botschaft 0x1A1 (V_VEH) - Signal combined event |
1 |
- |
| 0xD00B1D |
Botschaft 0x215 (ST_LP_EX_REAR_2_LH) - Signal combined event |
1 |
- |
| 0xD00B21 |
Botschaft 0x388 (Fahrzeugtyp) - Signal combined event |
1 |
- |
| 0xD00B24 |
Botschaft 0x3A0 (FZZSTD) - Signal combined event |
1 |
- |
| 0xD00B27 |
Botschaft 0x215 (ST_LP_EX_REAR_OTHER_SIDE_MASTER_1) - Signal combined event |
1 |
- |
| 0xD00B2A |
Botschaft 0x215 (ST_LP_EX_REAR_OTHER_SIDE_Slave_2) - Signal combined event |
1 |
- |
| 0xD00B2D |
Botschaft 0x3C (Con_VEH) - Signal combined event |
1 |
- |
| 0xD00B2F |
Botschaft 0x2FC (STAT_ZV_KLAPPEN) - Signal ST_CT_BTL |
1 |
- |
| 0xFFFFFF |
unbekannter Fehlerort |
0 |
- |
IUMWELTTEXTE
Dimensions: 92 rows × 9 columns
| UWNR |
UWTEXT |
UW_EINH |
L/H |
UWTYP |
NAME |
MUL |
DIV |
ADD |
| 0x1700 |
Kilometerstand |
TEXT |
High |
3 |
- |
- |
- |
- |
| 0x1701 |
Systemzeit |
s |
High |
signed long |
- |
1.0 |
1.0 |
0.0 |
| 0x1742 |
SWT_FEHLERWERT |
HEX |
High |
unsigned char |
- |
- |
- |
- |
| 0x1743 |
SWT_VIN |
TEXT |
High |
7 |
- |
1.0 |
1.0 |
0.0 |
| 0x1744 |
SWT_ID |
HEX |
High |
signed long |
- |
- |
- |
- |
| 0x1750 |
F_UW_BN |
- |
High |
signed char |
- |
1.0 |
1.0 |
0.0 |
| 0x1751 |
F_UW_TN |
TEXT |
High |
3 |
- |
1.0 |
1.0 |
0.0 |
| 0x1760 |
FSCSM_ERRORCODE |
0-n |
High |
0xFF |
FSCSM_ERRORCODE_TAB |
- |
- |
- |
| 0x4006 |
UWB_DEFEKT_ART_STRANG_LED1 |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_STRANG |
- |
- |
- |
| 0x4007 |
UWB_DEFEKT_ART_NTC |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_NTC |
- |
- |
- |
| 0x4008 |
Außentemperatur |
°C |
High |
unsigned char |
- |
0.5 |
1.0 |
-40.0 |
| 0x4009 |
Fahrzeuggeschwindigkeit |
km/h |
High |
unsigned int |
- |
0.015625 |
1.0 |
0.0 |
| 0x400A |
KLEMMENZUSTAND_PWF |
- |
High |
unsigned int |
- |
1.0 |
1.0 |
0.0 |
| 0x400B |
UWB Bordnetzspannung SysVolt |
V |
High |
unsigned char |
- |
0.1 |
1.0 |
0.0 |
| 0x400C |
UWB Signalname_0x2EB_CTRL_LP_EX |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X2CB_CTRL_LP_EX |
- |
- |
- |
| 0x400D |
UWB Timeout Botschaft 0x2EB CTR_LP_EX |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0x2EB_CTR_LP_EX |
- |
- |
- |
| 0x400E |
UWB_ALIVE_CRC_0x2EB_CTR_LP_EX |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X2EB_CTR_LP_EX |
- |
- |
- |
| 0x400F |
FLS_ERROR_SOURCE |
0-n |
High |
0xFF |
UWB_TAB_FLS_ERROR_SOURCE |
- |
- |
- |
| 0x4010 |
GPT_ERROR_SOURCE |
0-n |
High |
0xFF |
UWB_TAB_GPT_ERROR_SOURCE |
- |
- |
- |
| 0x4011 |
MCU_ERROR_SOURCE |
0-n |
High |
0xFF |
UWB_TAB_MCU_ERROR_SOURCE |
- |
- |
- |
| 0x4012 |
NVM_ERROR_SOURCE |
0-n |
High |
0xFF |
UWB_TAB_NVM_ERROR_SOURCE |
- |
- |
- |
| 0x4013 |
WDG_ERROR_SOURCE |
0-n |
High |
0xFF |
UWB_TAB_WDG_ERROR_SOURCE |
- |
- |
- |
| 0x4014 |
WDGM_ERROR_SOURCE |
0-n |
High |
0xFF |
UWB_TAB_WDGM_ERROR_SOURCE |
- |
- |
- |
| 0x4015 |
UWB Signal_0x1E4_error_source |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X1E4_CTR_LP_EX_2 |
- |
- |
- |
| 0x4016 |
UWB Timeout source of message 0X1E4_CTR_LP_EX_2 |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X1E4_CTR_LP_EX_2 |
- |
- |
- |
| 0x4018 |
UWB ALIVE_CRC_ERROR_CTR_LP_EX_2 |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X1E4_CTR_LP_EX_2 |
- |
- |
- |
| 0x4019 |
UWB SIGNAL_0X330_KILOMETERSTAND |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0x330_Kilometerstand |
- |
- |
- |
| 0x401A |
UWB Timeout_0X330_Kiliometerstand |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X330_KILOMETERSTAND |
- |
- |
- |
| 0x401B |
UWB_ALIVE_CRC_0X330_KILOMETERSTAND |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X330_KILOMETERSTAND |
- |
- |
- |
| 0x401C |
UWB SIGNAL_0X2CA_A_TEMP |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0x2CA_A_TEMP |
- |
- |
- |
| 0x401D |
UWB Timeout_0X2CA_A_TEMP |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0x2CA_A_Temp |
- |
- |
- |
| 0x401E |
UWB_ALIVE_CRC_0x2CA_A_TEMP |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0x2CA_A_Temp |
- |
- |
- |
| 0x401F |
UWB_SIGNAL_0x380_Fahrgestellnummer |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0x380_Fahrgestellnummer |
- |
- |
- |
| 0x4020 |
UWB_TIMEOUT_0X380_FAHRGESTELLNUMMER |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X380_FAHRGESTELLNUMMER |
- |
- |
- |
| 0x4021 |
UWB_ALIVE_CRC_0X380_FAHRGESTELLNUMMER |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X380_FAHRGESTELLNUMMER |
- |
- |
- |
| 0x4022 |
UWB_SIGNAL_0XCA_CTR_FN_IDC |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0XCA_CTR_FN_IDC |
- |
- |
- |
| 0x4023 |
UWB_TIMEOUT_0XCA_CTR_FN_IDC |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_CRC_0XCA_CTR_FN_IDC |
- |
- |
- |
| 0x4024 |
UWB_ALIVE_CRC_0XCA_CTR_FN_IDC |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0XCA_CTR_FN_IDC |
- |
- |
- |
| 0x4025 |
UWB_SIGNAL_0X328_RELATIVZEIT |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X328_RELATIVZEIT |
- |
- |
- |
| 0x4026 |
UWB_TIMEOUT_0X328_RELATIVZEIT |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X328_RELATIVZEIT |
- |
- |
- |
| 0x4027 |
UWB_ALIVE_CRC_0X328_RELATIVZEIT |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X328_RELATIVZEIT |
- |
- |
- |
| 0x4028 |
UWB_SIGNAL_0X32_ST_CENG |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X32_ST_CENG |
- |
- |
- |
| 0x4029 |
UWB_TIMEOUT_0X32_ST_CENG |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X32_ST_CENG |
- |
- |
- |
| 0x402A |
UWB_ALIVE_CRC__0X32_ST_CENG |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X32_ST_CENG |
- |
- |
- |
| 0x402B |
UWB_SIGNAL_0X1A1_V_VEH |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X1A1_V_VEH |
- |
- |
- |
| 0x402C |
UWB_TIMEOUT_0X1A1_V_VEH |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X1A1_V_VEH |
- |
- |
- |
| 0x402D |
UWB_ALIVE_CRC_0X1A1_V_VEH |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X1A1_V_VEH |
- |
- |
- |
| 0x402E |
UWB_SIGNAL_0X215_ST_LP_EX_REAR_SAME_SIDE |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X215_REAR_2 |
- |
- |
- |
| 0x402F |
UWB_TIMEOUT_0X215_ST_LP_EX_REAR_SAME_SIDE |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X215_ST_LP_EX_REAR |
- |
- |
- |
| 0x4030 |
UWB_ALIVE_CRC_0X215_ST_LP_EX_REAR_SAME_SIDE |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X215_ST_LP_EX_REAR |
- |
- |
- |
| 0x4031 |
UWB_SIGNAL_0X388_FAHRZEUGTYP |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X388_FAHRZEUGTYP |
- |
- |
- |
| 0x4032 |
UWB_TIMEOUT_0X388_FAHRZEUGTYP |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X388_FAHRZEUGTYP |
- |
- |
- |
| 0x4033 |
UWB_ALIVE_CRC_0X388_FAHRZEUGTYP |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X388_FAHRZEUGTYP |
- |
- |
- |
| 0x4034 |
UWB_SIGNAL_0X3A0_FZZSTD |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X3A0_FZZSTD |
- |
- |
- |
| 0x4035 |
UWB_TIMEOUT_0X3A0_FZZSTD |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X3A0_FZZSTD |
- |
- |
- |
| 0x4036 |
UWB_ALIVE_CRC_0X3A0_FZZSTD |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X3A0_FZZSTD |
- |
- |
- |
| 0x4039 |
UWB_OVERVOLTAGE_SEG_STRANG_1 |
0-n |
High |
0xFF |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_1 |
- |
- |
- |
| 0x403A |
UWB_OVERVOLTAGE_SEG_STRANG_2 |
0-n |
High |
0xFF |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_2 |
- |
- |
- |
| 0x403B |
UWB_OVERVOLTAGE_SEG_STRANG_3 |
0-n |
High |
0xFF |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_3 |
- |
- |
- |
| 0x403C |
UWB_OVERVOLTAGE_SEG_STRANG_4 |
0-n |
High |
0xFF |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_4 |
- |
- |
- |
| 0x403D |
UWB_OVERVOLTAGE_SEG_STRANG_5 |
0-n |
High |
0xFF |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_5 |
- |
- |
- |
| 0x403E |
UWB_OVERVOLTAGE_SEG_STRANG_6 |
0-n |
High |
0xFF |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_6 |
- |
- |
- |
| 0x403F |
UWB_UNDERVOLTAGE_SEG_STRANG_1 |
0-n |
High |
0xFF |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_1 |
- |
- |
- |
| 0x4040 |
UWB_UNDERVOLTAGE_SEG_STRANG_2 |
0-n |
High |
0xFF |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_2 |
- |
- |
- |
| 0x4041 |
UWB_UNDERVOLTAGE_SEG_STRANG_3 |
0-n |
High |
0xFF |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_3 |
- |
- |
- |
| 0x4042 |
UWB_UNDERVOLTAGE_SEG_STRANG_4 |
0-n |
High |
0xFF |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_4 |
- |
- |
- |
| 0x4043 |
UWB_UNDERVOLTAGE_SEG_STRANG_5 |
0-n |
High |
0xFF |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_5 |
- |
- |
- |
| 0x4044 |
UWB_UNDERVOLTAGE_SEG_STRANG_6 |
0-n |
High |
0xFF |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_6 |
- |
- |
- |
| 0x4045 |
UWB_SIGNAL_0X215_ST_LP_EX_REAR_OTHER_SIDE_MASTER_1 |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X215_REAR_2 |
- |
- |
- |
| 0x4046 |
UWB_TIMEOUT_0X215_ST_LP_EX_REAR_OTHER_SIDE_MASTER_1 |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X215_ST_LP_EX_REAR |
- |
- |
- |
| 0x4047 |
UWB_ALIVE_CRC_0X215_ST_LP_EX_REAR_OTHER_SIDE_MASTER_1 |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X215_ST_LP_EX_REAR |
- |
- |
- |
| 0x4048 |
UWB_SIGNAL_0X215_ST_LP_EX_REAR_OTHER_SIDE_SLAVE_2 |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X215_REAR_2 |
- |
- |
- |
| 0x4049 |
UWB_TIMEOUT_0X215_ST_LP_EX_REAR_OTHER_SIDE_SLAVE_2 |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X215_ST_LP_EX_REAR |
- |
- |
- |
| 0x404A |
UWB_ALIVE_CRC_0X215_ST_LP_EX_REAR_OTHER_SIDE_SLAVE_2 |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X215_ST_LP_EX_REAR |
- |
- |
- |
| 0x404B |
UWB_TIMEOUT_0X3C_CON_VEH |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0X3C_CON_VEH |
- |
- |
- |
| 0x404C |
UWB_ALIVE_CRC_0X3C_Con_VEH |
0-n |
High |
0xFF |
UWB_TAB_ALIVE_CRC_0X3C_CON_VEH |
- |
- |
- |
| 0x404D |
UWB_SIGNAL_0X3C_Con_VEH |
0-n |
High |
0xFF |
UWB_TAB_SIGNAL_0X3C_Con_VEH |
- |
- |
- |
| 0x404E |
UWB_TIMEOUT_0X2FC_STAT_ZV_KLAPPEN |
0-n |
High |
0xFF |
UWB_TAB_TIMEOUT_0x2FC_STAT_ZV_KLAPPEN |
- |
- |
- |
| 0x404F |
UWB_DEFEKT_ART_STRANG_LED2 |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_STRANG |
- |
- |
- |
| 0x4050 |
UWB_DEFEKT_ART_STRANG_LED3 |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_STRANG |
- |
- |
- |
| 0x4051 |
UWB_DEFEKT_ART_STRANGLED4 |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_STRANG |
- |
- |
- |
| 0x4052 |
UWB_DEFEKT_ART_STRANG_LED5 |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_STRANG |
- |
- |
- |
| 0x4053 |
UWB_DEFEKT_ART_STRANG_LED6 |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_STRANG |
- |
- |
- |
| 0x4054 |
UWB_DEFEKT_ART_STRANG_LED7 |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_STRANG |
- |
- |
- |
| 0x4055 |
UWB_DEFEKT_ART_NTC |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_NTC |
- |
- |
- |
| 0x4056 |
UWB_DEFEKT_ART_NTC |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_NTC |
- |
- |
- |
| 0x4057 |
UWB_DEFEKT_ART_NTC |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_NTC |
- |
- |
- |
| 0x4058 |
UWB_DEFEKT_ART_NTC |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_NTC |
- |
- |
- |
| 0x4059 |
UWB_DEFEKT_ART_STRANG_HSS |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_STRANG |
- |
- |
- |
| 0x405A |
UWB_CONFIGURATION_DATA_INVALID |
0-n |
High |
0xFF |
UWB_TAB_CONFIGURATION_DATA_INVALID |
- |
- |
- |
| 0x405B |
UWB_DEFEKT_ART_NOTLAUFAKTIVIERUNG |
0-n |
High |
0xFF |
UWB_TAB_DEFEKT_ART_NOTLAUFAKTIVIERUNG |
- |
- |
- |
| 0xXYXY |
unbekannte Umweltbedingung |
- |
- |
- |
- |
- |
- |
- |
JOBRESULTEXTENDED
Dimensions: 1 rows × 2 columns
| SB |
STATUS_TEXT |
| 0xXY |
ERROR_UNKNOWN |
KANAL_RLM
Dimensions: 9 rows × 2 columns
| WERT |
TEXT |
| 0 |
alle |
| 1 |
Kanal 1 |
| 2 |
Kanal 2 |
| 3 |
Kanal 3 |
| 4 |
Kanal 4 |
| 5 |
Kanal 5 |
| 6 |
Kanal 6 |
| 7 |
Kanal 7 |
| 8 |
Kanal 8 |
RDBI_ADS_DOP
Dimensions: 10 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
ISOSAEReserved_00 |
| 0x01 |
defaultSession |
| 0x02 |
programmingSession |
| 0x03 |
extendedDiagnosticSession |
| 0x04 |
safetySystemDiagnosticSession |
| 0x40 |
vehicleManufacturerSpecific_40 |
| 0x41 |
codingSession |
| 0x42 |
SWTSession |
| 0x43 |
HDDUpdateSession |
| 0xff |
ungültig |
RDBI_PC_PCS_DOP
Dimensions: 4 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
ECU mehrmals programmierbar |
| 0x01 |
ECU mindestens einmal vollstaendig programmierbar |
| 0x02 |
ECU nicht mehr programmierbar |
| 0xff |
ungültig |
RES_0X2502_D
Dimensions: 3 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_RESERVE_WERT |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Reserve. Konstante = 0x00 |
| STAT_PROG_ZAEHLER_STATUS |
0-n |
high |
unsigned char |
- |
RDBI_PC_PCS_DOP |
- |
- |
- |
ProgrammingCounterStatus |
| STAT_PROG_ZAEHLER_WERT |
- |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
ProgrammingCounter |
RES_0X2504_D
Dimensions: 6 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_ERASE_MEMORY_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
EraseMemoryTime, maximale SWE-Löschzeit mit Ablaufkontrolle im Steuergerät. |
| STAT_CHECK_MEMORY_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
CheckMemoryTime (Bsp.: Signaturprüfung), maximale Speicherprüfzeit mit Ablaufkontrolle im Steuergerät. |
| STAT_BOOTLOADER_INSTALLATION_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
BootloaderInstallationTime Die Zeit, die nach dem Reset benötigt wird, damit der Hilfsbootloader gestartet wird, den Bootloader löscht, den neuen Bootloader kopiert, dessen Signatur prüf und der neue Bootloader gestartet wird bis er wieder diagnosefähig ist. Angabe ist verpflichtend für alle Steuergeräte, auch wenn das Steuergerät keinen Bootloader Update geplant hat. Ein Wert von 0x0000 ist verboten. |
| STAT_AUTHENTICATION_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
AuthenticationTime, die maximale Zeit, die das Steuergerät zur Prüfung der Authentisierung (sendKey) benötigt mit Ablaufkontrolle im Steuergerät. |
| STAT_RESET_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
ResetTime Die Zeitangabe bezieht sich auf den Übergang von der ApplicationExtendedSesssion in die ProgrammingSession bzw. bei Übergang von der ProgrammingSession in die DefaultSession. Es ist der Maximalwert auszugeben. Nach Ablauf der ResetTime ist das Steuergerät durch Diagnose ansprechbar. |
| STAT_TRANSFER_DATA_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
TransferDataTime Die Angabe hat sich zu beziehen auf einen TransferData mit maximaler Blocklänge auf die Zeitspanne vom vollständigen Empfang der Daten im Steuergerät über das ggf. erforderliche Dekomprimieren und dem vollständigen Speichern im nichtflüchtigen Speicher bis einschließlich dem Senden der positiven Response. |
RES_0X4003_D
Dimensions: 8 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_BINNING_CHANNEL_1_WERT |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Binning class for channel 1 |
| STAT_BINNING_CHANNEL_2_WERT |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Binning class for channel 2 |
| STAT_BINNING_CHANNEL_3_WERT |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Binning class for channel 3 |
| STAT_BINNING_CHANNEL_4_WERT |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Binning class for channel 4 |
| STAT_BINNING_CHANNEL_5_WERT |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Binning class for channel 5 |
| STAT_BINNING_CHANNEL_6_WERT |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Binning class for channel 6 |
| STAT_BINNING_CHANNEL_7_WERT |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Binning class for channel 7 |
| STAT_DUMMY_WERT |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Platzhalter |
RES_0X4004_D
Dimensions: 12 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_LAMP_SUPPLIER_TEXT |
TEXT |
high |
string[6] |
- |
- |
1.0 |
1.0 |
0.0 |
Name of the Lamp Supplier |
| STAT_SUPPLIER_PLANT_TEXT |
TEXT |
high |
string[6] |
- |
- |
1.0 |
1.0 |
0.0 |
Assembly plant of the rear lamp |
| STAT_PRODUCTION_DATE_WERT |
- |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Production date of the rear lamp. Format: YYYYMMDD |
| STAT_SERIAL_NUMBER_TEXT |
TEXT |
high |
string[16] |
- |
- |
1.0 |
1.0 |
0.0 |
Serial Number of the lamp |
| STAT_LED_TYPE_CHANEL_1_TEXT |
TEXT |
high |
string[10] |
- |
- |
1.0 |
1.0 |
0.0 |
OLED/LED Supplier and LED Type |
| STAT_LED_TYPE_CHANEL_2_TEXT |
TEXT |
high |
string[10] |
- |
- |
1.0 |
1.0 |
0.0 |
OLED/LED Supplier and LED Type |
| STAT_LED_TYPE_CHANEL_3_TEXT |
TEXT |
high |
string[10] |
- |
- |
1.0 |
1.0 |
0.0 |
OLED/LED Supplier and LED Type |
| STAT_LED_TYPE_CHANEL_4_TEXT |
TEXT |
high |
string[10] |
- |
- |
1.0 |
1.0 |
0.0 |
OLED/LED Supplier and LED Type |
| STAT_LED_TYPE_CHANEL_5_TEXT |
TEXT |
high |
string[10] |
- |
- |
1.0 |
1.0 |
0.0 |
OLED/LED Supplier and LED Type |
| STAT_LED_TYPE_CHANEL_6_TEXT |
TEXT |
high |
string[10] |
- |
- |
1.0 |
1.0 |
0.0 |
OLED/LED Supplier and LED Type |
| STAT_LED_TYPE_CHANEL_7_TEXT |
TEXT |
high |
string[10] |
- |
- |
1.0 |
1.0 |
0.0 |
OLED/LED Supplier and LED Type |
| STAT_HARDWARE_VARIANT |
0-n |
high |
unsigned char |
- |
TAB_HARDWARE_VARIANT |
- |
- |
- |
SAE/ECE value |
RES_0X4037_D
Dimensions: 44 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_01_PWM_LED_1_1_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 1 vor thermo calculation |
| STAT_02_PWM_LED_1_1_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 1 nach thermo calculation |
| STAT_03_PWM_LED_1_2_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 1 vor thermo calculation |
| STAT_04_PWM_LED_1_2_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 1 nach thermo calculation |
| STAT_05_PWM_LED_1_3_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 1 vor thermo calculation |
| STAT_06_PWM_LED_1_3_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 1 nach thermo calculation |
| STAT_07_PWM_LED_2_1_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 2 vor thermo calculation |
| STAT_08_PWM_LED_2_1_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 2 nach thermo calculation |
| STAT_09_PWM_LED_2_2_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 2 vor thermo calculation |
| STAT_10_PWM_LED_2_2_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 2 nach thermo calculation |
| STAT_11_PWM_LED_2_3_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 2 vor thermo calculation |
| STAT_12_PWM_LED_2_3_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 2 nach thermo calculation |
| STAT_13_PWM_LED_3_1_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 3 vor thermo calculation |
| STAT_14_PWM_LED_3_1_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 3 nach thermo calculation |
| STAT_15_PWM_LED_3_2_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 3 vor thermo calculation |
| STAT_16_PWM_LED_3_2_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 3 nach thermo calculation |
| STAT_17_PWM_LED_3_3_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 3 vor thermo calculation |
| STAT_18_PWM_LED_3_3_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 3 nach thermo calculation |
| STAT_19_PWM_LED_4_1_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 4 vor thermo calculation |
| STAT_20_PWM_LED_4_1_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 4 nach thermo calculation |
| STAT_21_PWM_LED_4_2_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 4 vor thermo calculation |
| STAT_22_PWM_LED_4_2_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 4 nach thermo calculation |
| STAT_23_PWM_LED_4_3_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 4 vor thermo calculation |
| STAT_24_PWM_LED_4_3_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 4 nach thermo calculation |
| STAT_25_PWM_LED_5_1_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 5 vor thermo calculation |
| STAT_26_PWM_LED_5_1_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 5 nach thermo calculation |
| STAT_27_PWM_LED_5_2_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 5 vor thermo calculation |
| STAT_28_PWM_LED_5_2_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 5 nach thermo calculation |
| STAT_29_PWM_LED_6_1_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 6 vor thermo calculation |
| STAT_30_PWM_LED_6_1_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 6 nach thermo calculation |
| STAT_31_PWM_LED_6_2_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 6 vor thermo calculation |
| STAT_32_PWM_LED_6_2_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 6 nach thermo calculation |
| STAT_33_PWM_LED_6_3_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 6 vor thermo calculation |
| STAT_34_PWM_LED_6_3_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 6 nach thermo calculation |
| STAT_35_PWM_LED_6_4_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 6 vor thermo calculation |
| STAT_36_PWM_LED_6_4_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 6 nach thermo calculation |
| STAT_37_PWM_LED_6_5_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 6 vor thermo calculation |
| STAT_38_PWM_LED_6_5_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 6 nach thermo calculation |
| STAT_39_PWM_LED_6_6_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 6vor thermo calculation |
| STAT_40_PWM_LED_6_6_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED 6 nach thermo calculation |
| STAT_41_PWM_STRANG_7_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED Strang 7 vor thermo calulation |
| STAT_42_PWM_STRANG_7_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED Strang 7 nach thermo calculation |
| STAT_43_PWM_STRANG_8_PRE_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED Strang 8 vor thermo calulation |
| STAT_44_PWM_STRANG_8_POST_WERT |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
pwm für LED Strang 8 nach thermo calculation |
RES_0X4038_D
Dimensions: 8 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_NTC1_ECU_TEMP_WERT |
°C |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
-40.0 |
NTC1 ECU Temperaturwert in Grad Celcius 0: means -40 190: means 150 |
| STAT_NTC2_TEMP_WERT |
°C |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
-40.0 |
NTC2 Temperaturwert in Grad Celcius 0: means -40 190: means 150 |
| STAT_NTC3_TEMP_WERT |
°C |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
-40.0 |
NTC3 Temperaturwert in Grad Celcius 0: means -40 190: means 150 |
| STAT_NTC4_TEMP_WERT |
°C |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
-40.0 |
NTC4 Temperaturwert in Grad Celcius 0: means -40 190: means 150 |
| STAT_NTC5_TEMP_WERT |
°C |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
-40.0 |
NTC5 Temperaturwert in Grad Celcius 0: means -40 190: means 150 |
| STAT_NTC13_TEMP_WERT |
°C |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
-40.0 |
VIRT NTC 13 Temperaturwert in Grad Celcius 0: means -40 190: means 150 |
| STAT_NTC14_TEMP_WERT |
°C |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
-40.0 |
VIRT NTC 14 Temperaturwert in Grad Celcius 0: means -40 190: means 150 |
| STAT_NTC15_TEMP_WERT |
°C |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
-40.0 |
VIRT NTC 15 Temperaturwert in Grad Celcius 0: means -40 190: means 150 |
RES_0XA5A8_R
Dimensions: 22 rows × 13 columns
| RESULTNAME |
STR |
STPR |
RRR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_SEGMENT_01_CHAN_1 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 1 Kanal 1 |
| STAT_SEGMENT_02_CHAN_1 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 2 Kanal 1 |
| STAT_SEGMENT_03_CHAN_1 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 3 Kanal 1 |
| STAT_SEGMENT_04_CHAN_2 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 4 Kanal 2 |
| STAT_SEGMENT_05_CHAN_2 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 5 Kanal 2 |
| STAT_SEGMENT_06_CHAN_2 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 6 Kanal 2 |
| STAT_SEGMENT_07_CHAN_3 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 7 Kanal 3 |
| STAT_SEGMENT_08_CHAN_3 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 8 Kanal 3 |
| STAT_SEGMENT_09_CHAN_3 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 9 Kanal 3 |
| STAT_SEGMENT_10_CHAN_4 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 10 Kanal 4 |
| STAT_SEGMENT_11_CHAN_4 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 11 Kanal 4 |
| STAT_SEGMENT_12_CHAN_4 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 12 Kanal 4 |
| STAT_SEGMENT_13_CHAN_5 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 13 Kanal 5 |
| STAT_SEGMENT_14_CHAN_5 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 14 Kanal 5 |
| STAT_SEGMENT_15_CHAN_6 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 15 Kanal 6 |
| STAT_SEGMENT_16_CHAN_6 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 16 Kanal 6 |
| STAT_SEGMENT_17_CHAN_6 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 17 Kanal 6 |
| STAT_SEGMENT_18_CHAN_6 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 18 Kanal 6 |
| STAT_SEGMENT_19_CHAN_6 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 19 Kanal 6 |
| STAT_SEGMENT_20_CHAN_6 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 20 Kanal 6 |
| STAT_SEGMENT_21_CHAN_7 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 21 Kanal 7 |
| STAT_SEGMENT_22_CHAN_8 |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_FunktionstestRlm_Segmentresult |
- |
- |
- |
Segment 22 Kanal 8 |
RES_0XD6DA_D
Dimensions: 16 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_KANAL_1 |
0-n |
high |
unsigned char |
- |
STATUS_RLM_KANAL |
- |
- |
- |
Status Kanal 1 |
| STAT_PWM_KANAL_1 |
0-n |
high |
unsigned char |
- |
- |
- |
- |
- |
Der PWM-Wert des Kanals (in %) |
| STAT_KANAL_2 |
0-n |
high |
unsigned char |
- |
STATUS_RLM_KANAL |
- |
- |
- |
Status Kanal 2 |
| STAT_PWM_KANAL_2 |
0-n |
high |
unsigned char |
- |
- |
- |
- |
- |
Der PWM-Wert des Kanals (in %) |
| STAT_KANAL_3 |
0-n |
high |
unsigned char |
- |
STATUS_RLM_KANAL |
- |
- |
- |
Status Kanal 3 |
| STAT_PWM_KANAL_3 |
0-n |
high |
unsigned char |
- |
- |
- |
- |
- |
Der PWM-Wert des Kanals (in %) |
| STAT_KANAL_4 |
0-n |
high |
unsigned char |
- |
STATUS_RLM_KANAL |
- |
- |
- |
Status Kanal 4 |
| STAT_PWM_KANAL_4 |
0-n |
high |
unsigned char |
- |
- |
- |
- |
- |
Der PWM-Wert des Kanals (in %) |
| STAT_KANAL_5 |
0-n |
high |
unsigned char |
- |
STATUS_RLM_KANAL |
- |
- |
- |
Status Kanal 5 |
| STAT_PWM_KANAL_5 |
0-n |
high |
unsigned char |
- |
- |
- |
- |
- |
Der PWM-Wert des Kanals (in %) |
| STAT_KANAL_6 |
0-n |
high |
unsigned char |
- |
STATUS_RLM_KANAL |
- |
- |
- |
Status Kanal 6 |
| STAT_PWM_KANAL_6 |
0-n |
high |
unsigned char |
- |
- |
- |
- |
- |
Der PWM-Wert des Kanals (in %) |
| STAT_KANAL_7 |
0-n |
high |
unsigned char |
- |
STATUS_RLM_KANAL |
- |
- |
- |
Status Kanal 7 |
| STAT_PWM_KANAL_7 |
0-n |
high |
unsigned char |
- |
- |
- |
- |
- |
Der PWM-Wert des Kanals (in %) |
| STAT_KANAL_8 |
0-n |
high |
unsigned char |
- |
STATUS_RLM_KANAL |
- |
- |
- |
Status Kanal 8 |
| STAT_PWM_KANAL_8 |
0-n |
high |
unsigned char |
- |
- |
- |
- |
- |
Der PWM-Wert des Kanals (in %) |
RES_0XD6DD_D
Dimensions: 16 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_STANDLICHT |
0-n |
- |
unsigned char |
- |
STATUS_RLM_FUNKTION |
- |
- |
- |
Status Standlicht |
| STAT_RUECKFAHRLICHT |
0-n |
- |
unsigned char |
- |
STATUS_RLM_FUNKTION |
- |
- |
- |
Status Rückfahrlicht |
| STAT_NEBELSCHLUSSLICHT |
0-n |
- |
unsigned char |
- |
STATUS_RLM_FUNKTION |
- |
- |
- |
Status Nebelschlusslicht |
| STAT_BREMSLICHT |
0-n |
- |
unsigned char |
- |
STATUS_RLM_FUNKTION |
- |
- |
- |
Status Bremslicht |
| STAT_PARKLICHT |
0-n |
- |
unsigned char |
- |
STATUS_RLM_FUNKTION |
- |
- |
- |
Status Parklicht |
| STAT_SEITENMARKIERUNGSLICHT |
0-n |
- |
unsigned char |
- |
STATUS_RLM_FUNKTION |
- |
- |
- |
Status Seitenmarkierungslicht |
| STAT_TAGFAHRLICHT |
0-n |
- |
unsigned char |
- |
STATUS_RLM_FUNKTION |
- |
- |
- |
Status Tagfahrlicht |
| STAT_FAHRTRICHTUNGSANZEIGER |
0-n |
- |
unsigned char |
- |
STATUS_RLM_FUNKTION |
- |
- |
- |
Status Fahrtrichtungsanzeiger |
| STAT_GOODBYE_LICHT |
0-n |
- |
unsigned char |
- |
STATUS_RLM_FUNKTION |
- |
- |
- |
Status Goodbye Light |
| STAT_WELCOME_LICHT |
0-n |
- |
unsigned char |
- |
STATUS_RLM_FUNKTION |
- |
- |
- |
Status Welcome Licht |
| STAT_FOLLOW_ME_HOME |
0-n |
- |
unsigned char |
- |
STATUS_RLM_FUNKTION |
- |
- |
- |
Status Follow me home |
| STAT_ESS_BLINKEN |
0-n |
- |
unsigned char |
- |
STATUS_RLM_FUNKTION |
- |
- |
- |
Status ESS Blinken |
| STAT_DWA_BLINKEN |
0-n |
- |
unsigned char |
- |
STATUS_RLM_FUNKTION |
- |
- |
- |
Status DWA Blinken |
| STAT_PANIK_BLINKEN |
0-n |
- |
unsigned char |
- |
STATUS_RLM_FUNKTION |
- |
- |
- |
Status Panik Blinken |
| STAT_UEBERFALL_ALARM |
0-n |
- |
unsigned char |
- |
STATUS_RLM_FUNKTION |
- |
- |
- |
Status Überfall Alarm |
| STAT_VIRTUAL_LIGHT_FUNCTION_TURN_INDICATOR |
0-n |
- |
unsigned char |
- |
STATUS_RLM_FUNKTION |
- |
- |
- |
Virtuelle Funktion, um den Fahrtrichtungsanzeiger permananet zu aktivieren. |
RES_0XF002_R
Dimensions: 6 rows × 13 columns
| RESULTNAME |
STR |
STPR |
RRR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_CLASS_1 |
+ |
- |
- |
0-n |
high |
unsigned long |
- |
- |
- |
- |
- |
Temperaturstatistik Class 1: T < 0 Grad C |
| STAT_CLASS_2 |
+ |
- |
- |
0-n |
high |
unsigned long |
- |
- |
- |
- |
- |
Temperaturstatistik Class 2: 0 < T < 95 Grad C |
| STAT_CLASS_3 |
+ |
- |
- |
0-n |
high |
unsigned long |
- |
- |
- |
- |
- |
Temperaturstatistik Class 3: 95 < T < 115 Grad C |
| STAT_CLASS_4 |
+ |
- |
- |
0-n |
high |
unsigned long |
- |
- |
- |
- |
- |
Temperaturstatistik Class 4: 115 < T < 135 Grad C |
| STAT_CLASS_5 |
+ |
- |
- |
0-n |
high |
unsigned long |
- |
- |
- |
- |
- |
Temperaturstatistik Class 5: 135 < T < 155 Grad C |
| STAT_CLASS_6 |
+ |
- |
- |
0-n |
high |
unsigned long |
- |
- |
- |
- |
- |
Temperaturstatistik Class 6: 155 < T Grad C |
RES_0XF003_R
Dimensions: 30 rows × 13 columns
| RESULTNAME |
STR |
STPR |
RRR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_DOUBLE_WEEK_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_1_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_2_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_3_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_4_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_5_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_6_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_7_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_8_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_9_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_10_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_11_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_12_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_13_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_14_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_15_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_16_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_17_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_18_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_19_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_20_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_21_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_22_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_23_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_24_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_25_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_26_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_27_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_28_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
| STAT_DOUBLE_WEEK_29_WERT |
+ |
- |
- |
mV |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
voltage of doubleweek |
RES_0XF100_R
Dimensions: 36 rows × 13 columns
| RESULTNAME |
STR |
STPR |
RRR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_01_LED_1_STROM_WERT |
- |
- |
+ |
mA |
high |
unsigned char |
- |
- |
10.0 |
1.0 |
0.0 |
Stromwert LED 1 |
| STAT_02_STRANG_1_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert Strang 1 |
| STAT_03_LED_1_1_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 11 |
| STAT_04_LED_1_2_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 12 |
| STAT_05_LED_1_3_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 13 |
| STAT_06_LED_2_STROM_WERT |
- |
- |
+ |
mA |
high |
unsigned char |
- |
- |
10.0 |
1.0 |
0.0 |
Stromwert LED 2 |
| STAT_07_STRANG_2_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert Strang 2 |
| STAT_08_LED_2_1_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 21 |
| STAT_09_LED_2_2_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 22 |
| STAT_10_LED_2_3_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 23 |
| STAT_11_LED_3_STROM_WERT |
- |
- |
+ |
mA |
high |
unsigned char |
- |
- |
10.0 |
1.0 |
0.0 |
Stromwert LED 3 |
| STAT_12_STRANG_3_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert Strang 3 |
| STAT_13_LED_3_1_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 31 |
| STAT_14_LED_3_2_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 32 |
| STAT_15_LED_3_3_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 33 |
| STAT_16_LED_4_STROM_WERT |
- |
- |
+ |
mA |
high |
unsigned char |
- |
- |
10.0 |
1.0 |
0.0 |
Stromwert LED 4 |
| STAT_17_STRANG_4_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert Strang 4 |
| STAT_18_LED_4_1_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 41 |
| STAT_19_LED_4_2_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 42 |
| STAT_20_LED_4_3_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 43 |
| STAT_21_LED_5_STROM_WERT |
- |
- |
+ |
mA |
high |
unsigned char |
- |
- |
10.0 |
1.0 |
0.0 |
Stromwert LED 5 |
| STAT_22_STRANG_5_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert Strang 5 |
| STAT_23_LED_5_1_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 51 |
| STAT_24_LED_5_2_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 52 |
| STAT_25_LED_6_STROM_WERT |
- |
- |
+ |
mA |
high |
unsigned char |
- |
- |
10.0 |
1.0 |
0.0 |
Stromwert LED 6 |
| STAT_26_STRANG_6_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert Strang 6 |
| STAT_27_LED_6_1_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 61 |
| STAT_28_LED_6_2_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 62 |
| STAT_29_LED_6_3_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 63 |
| STAT_30_LED_6_4_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 64 |
| STAT_31_LED_6_5_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 65 |
| STAT_32_LED_6_6_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 66 |
| STAT_33_LED_7_STROM_WERT |
- |
- |
+ |
mA |
high |
unsigned char |
- |
- |
10.0 |
1.0 |
0.0 |
Stromwert LED 7 |
| STAT_34_LED_7_1_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 71 |
| STAT_35_LED_8_STROM_WERT |
- |
- |
+ |
mA |
high |
unsigned char |
- |
- |
10.0 |
1.0 |
0.0 |
Stromwert LED 8 |
| STAT_36_LED_8_1_PWM_WERT |
- |
- |
+ |
% |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Prozent Wert LED 81 |
RES_0XF152_D
Dimensions: 2 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_HW_MODIFICATION_INDEX_WERT |
HEX |
high |
unsigned char |
- |
- |
- |
- |
- |
Index of hardware modification: FF: Not supported index |
| - |
Bit |
high |
BITFIELD |
- |
BF_22_F152_SUPPLIERINFO |
- |
- |
- |
Tab Supplierinfo |
RES_0XFD00_D
Dimensions: 2 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_RESET_ZAEHLER |
0-n |
high |
unsigned char |
- |
- |
- |
- |
- |
Zaehlerstand des Reset Zaehlers |
| STAT_WATCHDOG_ZAEHLER |
0-n |
high |
unsigned char |
- |
- |
- |
- |
- |
Zaehlerstand Watchdog Zaehlers |
RES_0XFD01_D
Dimensions: 22 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_BULB_OP_TIMER1_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 1 |
| STAT_BULB_OP_TIMER2_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 2 |
| STAT_BULB_OP_TIMER3_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 3 |
| STAT_BULB_OP_TIMER4_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 4 |
| STAT_BULB_OP_TIMER5_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 5 |
| STAT_BULB_OP_TIMER6_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 6 |
| STAT_BULB_OP_TIMER7_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 7 |
| STAT_BULB_OP_TIMER8_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 8 |
| STAT_BULB_OP_TIMER9_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 9 |
| STAT_BULB_OP_TIMER10_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 10 |
| STAT_BULB_OP_TIMER11_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 11 |
| STAT_BULB_OP_TIMER12_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 12 |
| STAT_BULB_OP_TIMER13_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 13 |
| STAT_BULB_OP_TIMER14_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 14 |
| STAT_BULB_OP_TIMER15_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 15 |
| STAT_BULB_OP_TIMER16_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 16 |
| STAT_BULB_OP_TIMER17_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 17 |
| STAT_BULB_OP_TIMER18_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 18 |
| STAT_BULB_OP_TIMER19_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 19 |
| STAT_BULB_OP_TIMER20_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 20 |
| STAT_BULB_OP_TIMER21_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 21 |
| STAT_BULB_OP_TIMER22_WERT |
Counts |
high |
unsigned long |
- |
- |
1.0 |
1.0 |
0.0 |
Statistic Timer for Segment 22 |
RES_0XFD04_D
Dimensions: 20 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_STACK_POINTER_1_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content SP |
| STAT_PC_1_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content programming counter |
| STAT_STACK_POINTER_2_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content SP |
| STAT_PC_2_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content programming counter |
| STAT_STACK_POINTER_3_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content SP |
| STAT_PC_3_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content programming counter |
| STAT_STACK_POINTER_4_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content SP |
| STAT_PC_4_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content programming counter |
| STAT_STACK_POINTER_5_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content SP |
| STAT_PC_5_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content programming counter |
| STAT_STACK_POINTER_6_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content SP |
| STAT_PC_6_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content programming counter |
| STAT_STACK_POINTER_7_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content SP |
| STAT_PC_7_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content programming counter |
| STAT_STACK_POINTER_8_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content SP |
| STAT_PC_8_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content programming counter |
| STAT_STACK_POINTER_9_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content SP |
| STAT_PC_9_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content programming counter |
| STAT_STACK_POINTER_10_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content SP |
| STAT_PC_10_WERT |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
content programming counter |
SG_FUNKTIONEN
Dimensions: 29 rows × 16 columns
| ARG |
ID |
RESULTNAME |
INFO |
EINHEIT |
LABEL |
L/H |
DATENTYP |
NAME |
MUL |
DIV |
ADD |
SG_ADR |
SERVICE |
ARG_TABELLE |
RES_TABELLE |
| PROGRAMMING_COUNTER |
0x2502 |
- |
Programming-Counter |
- |
- |
- |
- |
- |
- |
- |
- |
- |
22 |
- |
RES_0x2502_D |
| PROGRAMMING_COUNTER_MAX_VALUE |
0x2503 |
STAT_PROG_MAX_WERT |
maximalen Anzahl von Programmiervorgängen |
- |
- |
High |
unsigned int |
- |
1.0 |
1.0 |
0.0 |
- |
22 |
- |
- |
| FLASH_TIMING_PARAMETER |
0x2504 |
- |
Programmierspezifische Timing Parameter |
- |
- |
- |
- |
- |
- |
- |
- |
- |
22 |
- |
RES_0x2504_D |
| MILE_KM_EEPROM |
0x2540 |
STAT_MILE_KM_EEPROM_DATA |
Im EEPROM abgelegter Kilometerstand. |
DATA |
- |
High |
data[3] |
- |
1.0 |
1.0 |
0.0 |
- |
22 |
- |
- |
| _RESET_ECU_VARIANT |
0x4000 |
- |
Entwicklerjob für das Rücksetzen der vergebenen ECU-Variante |
- |
- |
- |
- |
- |
- |
- |
- |
- |
2E |
ARG_0x4000_D |
- |
| _WRITE_SUPPLIER_INFO |
0x4001 |
- |
Lamp-Supplier-Information, Productiondate, LED-Types, ... |
- |
- |
- |
- |
- |
- |
- |
- |
- |
2E |
ARG_0x4001_D |
- |
| _WRITE_BINNING_DATA |
0x4002 |
- |
Binning information for each channel |
- |
- |
- |
- |
- |
- |
- |
- |
- |
2E |
ARG_0x4002_D |
- |
| READ_BINNING_INFO |
0x4003 |
- |
READ BINNING Information |
- |
- |
- |
- |
- |
- |
- |
- |
- |
22 |
- |
RES_0x4003_D |
| READ_SUPPLIER_INFO |
0x4004 |
- |
Reading supplier informatin |
- |
- |
- |
- |
- |
- |
- |
- |
- |
22 |
- |
RES_0x4004_D |
| READ_NTC_PWM |
0x4037 |
- |
Read NTC values before and after thermo calculation |
- |
- |
- |
- |
- |
- |
- |
- |
- |
22 |
- |
RES_0x4037_D |
| READ_NTC_TEMP |
0x4038 |
- |
Auslesen der Temperaturwerte aus allen DTC's |
- |
- |
- |
- |
- |
- |
- |
- |
- |
22 |
- |
RES_0x4038_D |
| RESET_SUPPLIER_DATA |
0x4061 |
- |
Reset Supplier Data in NVM |
- |
- |
- |
- |
- |
- |
- |
- |
- |
2E |
ARG_0x4061_D |
- |
| RESET_BINNING_DATA |
0x4062 |
- |
Reset binning data in NVM to default value |
- |
- |
- |
- |
- |
- |
- |
- |
- |
2E |
ARG_0x4062_D |
- |
| FUNKTIONSTEST_RLM |
0xA5A8 |
- |
Funktionstest RLM |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
- |
RES_0xA5A8_R |
| RLM_KANAL |
0xD6DA |
- |
Diagnose RLM Kanäle |
- |
- |
- |
- |
- |
- |
- |
- |
- |
2E;22 |
ARG_0xD6DA_D |
RES_0xD6DA_D |
| LEUCHTEN_FUNKTION_RLM |
0xD6DD |
- |
Leuchtfunktion |
- |
- |
- |
- |
- |
- |
- |
- |
- |
2E;22 |
ARG_0xD6DD_D |
RES_0xD6DD_D |
| RLM_EINGANGSSPANNUNG |
0xE2EB |
STAT_SPANNUNG_KLEMME_LICHT_WERT |
Eingangsspannung am Steuergerät |
mV |
- |
High |
unsigned int |
- |
1.0 |
1.0 |
0.0 |
- |
22 |
- |
- |
| STEUERN_SUPPLIERROUTINE_SUBSERVICE |
0xF000 |
- |
SupplierRoutine 1 - Anwendung nur durch SG-Lieferant nur in Diagnose-Modus SYSTEM_SUPPLIER_SPECIFIC_61 ausführbar |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
- |
- |
| STEUERN_SUPPLIERROUTINE_CONTROL |
0xF001 |
- |
SupplierRoutine2 - Anwendung nur SG-Lieferant nur in Diagnose-Modus SYSTEM_SUPPLIER_SESSION_61 ausführbar |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
- |
- |
| STEUERN_READ_CHANNEL_TEMPERATURE_STATISTIC |
0xF002 |
- |
Lese Temperaturstatisticv pro Kanal [1..8] |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
ARG_0xF002_R |
RES_0xF002_R |
| READ_CHANNEL_VOLTAGE_STATISTIC |
0xF003 |
- |
Lese Voltagestatistik pro Kanal [1..7] |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
ARG_0xF003_R |
RES_0xF003_R |
| _STEUERN_LEUCHTEN_AUSSENLICHT_KANAL |
0xF100 |
- |
Ansteuern der einzelnen LED Kanäle |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
ARG_0xF100_R |
RES_0xF100_R |
| READHWMODIFICATIONINDEX |
0xF152 |
- |
Dieser Service kommt nur zum Einsatz, wenn es eine geringfügige Hardwareänderung an dem Steuergerät gegeben hat, die nicht zu einer Änderung der Sachnummer bzw. der Hardware SGBM-IDs geführt hat. Eine solche Änderung ist von außen nicht diagnostizierbar, daher wurde dieser Dienst dafür eingeführt. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
22 |
- |
RES_0xF152_D |
| ACTIVE_DIAGNOSTIC_SESSION |
0xF186 |
STAT_ACTIVE_DIAGNOSTIC_SESSION |
activeDiagnosticSession |
0-n |
- |
High |
unsigned char |
RDBI_ADS_DOP |
- |
- |
- |
- |
22 |
- |
- |
| RESET_ZAEHLER |
0xFD00 |
- |
Ruecksetzen / auslesen der Resetzähler für Reset und Watchdog |
- |
- |
- |
- |
- |
- |
- |
- |
- |
2E;22 |
ARG_0xFD00_D |
RES_0xFD00_D |
| BULB_OP_TIMERS |
0xFD01 |
- |
Read/Reset Bulp operation timers |
- |
- |
- |
- |
- |
- |
- |
- |
- |
2E;22 |
ARG_0xFD01_D |
RES_0xFD01_D |
| RESET_STATISTIC_TEMPERATURE_HISTOGRAMM |
0xFD02 |
- |
Rücksetzten Temperatur History eines Kanals [1..8] |
- |
- |
- |
- |
- |
- |
- |
- |
- |
2E |
ARG_0xFD02_D |
- |
| RESET_STATISTIC_VOLTAGE_HISTOGRAM |
0xFD03 |
- |
Rücksetzten der Voltage Staistic Daten für einen Kanal [1..7] |
- |
- |
- |
- |
- |
- |
- |
- |
- |
2E |
ARG_0xFD03_D |
- |
| RESET_VECTOR |
0xFD04 |
- |
Lesen / Rücksetzen einer Liste von Resetvektoren bestehend aus Stackpointer und program counter. Die Liste wird beim Auslösen des WDG befüllt |
- |
- |
- |
- |
- |
- |
- |
- |
- |
22;2E |
ARG_0xFD04_D |
RES_0xFD04_D |
STATUS_RLM_FUNKTION
Dimensions: 4 rows × 2 columns
| WERT |
TEXT |
| 0 |
aus |
| 1 |
ein |
| 254 |
nicht unterstützt |
| 255 |
nicht verbaut |
STATUS_RLM_KANAL
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 0 |
aus |
| 1 |
ein |
| 255 |
nicht verbaut |
TAB_ACV_FN_IDC
Dimensions: 29 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
Blinken_Aus |
| 0x01 |
Crash_Blinken |
| 0x02 |
Reversier_Blinken |
| 0x03 |
Quittierungsblinken_Schaerfen |
| 0x04 |
Quittierungsblinken_Entschaerfen |
| 0x05 |
DWA_Blinken |
| 0x06 |
Warnblinken_manuell |
| 0x07 |
Dauerblinken_links |
| 0x08 |
Dauerblinken_rechts |
| 0x09 |
Tippblinken_links |
| 0x0A |
Tippblinken_rechts |
| 0x0B |
Ueberfallalarm |
| 0x0C |
FAS_Warnblinken_Auspraegung_1 |
| 0x0D |
Auffahrwarnblinken |
| 0x0E |
Ankuendigungsblinken_Oeffnen |
| 0x0F |
Ankuendigungsblinken_Schliessen |
| 0x10 |
Warnblinken_nach_Gefahrenbremsung |
| 0x11 |
Warnblinken_von_RCP |
| 0x12 |
FAS_Richtungsblinken_lowPrio_links |
| 0x13 |
FAS_Richtungsblinken_lowPrio_rechts |
| 0x14 |
FAS_Richtungsblinken_midPrio_links |
| 0x15 |
FAS_Richtungsblinken_midPrio_rechts |
| 0x16 |
FAS_Richtungsblinken_highPrio_links |
| 0x17 |
FAS_Richtungsblinken_highPrio_rechts |
| 0x18 |
FAS_Warnblinken_Auspraegung_2 |
| 0x19 |
FAS_Warnblinken_Auspraegung_3 |
| 0xFD |
Reserviert_nicht_verfuegbar |
| 0xFE |
Reserviert_Fehler |
| 0xFF |
Signal_unbefuellt |
TAB_BULB_OP_TIME_RESET
Dimensions: 22 rows × 2 columns
| WERT |
TEXT |
| 0 |
reset light bulp operation time counter segment 1 |
| 1 |
reset light bulp operation time counter segment 2 |
| 2 |
reset light bulp operation time counter segment 3 |
| 3 |
reset light bulp operation time counter segment 4 |
| 4 |
reset light bulp operation time counter segment 5 |
| 5 |
reset light bulp operation time counter segment 6 |
| 6 |
reset light bulp operation time counter segment 7 |
| 7 |
reset light bulp operation time counter segment 8 |
| 8 |
reset light bulp operation time counter segment 9 |
| 9 |
reset light bulp operation time counter segment 10 |
| 10 |
reset light bulp operation time counter segment 11 |
| 11 |
reset light bulp operation time counter segment 12 |
| 12 |
reset light bulp operation time counter segment 13 |
| 13 |
reset light bulp operation time counter segment 14 |
| 14 |
reset light bulp operation time counter segment 15 |
| 15 |
reset light bulp operation time counter segment 16 |
| 16 |
reset light bulp operation time counter segment 17 |
| 17 |
reset light bulp operation time counter segment 18 |
| 18 |
reset light bulp operation time counter segment 19 |
| 19 |
reset light bulp operation time counter segment 20 |
| 20 |
reset light bulp operation time counter segment 21 |
| 21 |
reset light bulp operation time counter segment 22 |
TAB_CTR_BFD
Dimensions: 7 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
INIT |
| 0x01 |
OFF_BFD |
| 0x02 |
BFD_MODE_1 |
| 0x03 |
BFD_MODE_2 |
| 0x04 |
BFD_MODE_3 |
| 0x05 |
BFD_MODE_4 |
| 0x0F |
Signal ungültig |
TAB_CTR_BL
Dimensions: 4 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
INIT |
| 0x01 |
OFF_BL |
| 0x02 |
ON_BL |
| 0x03 |
Signal ungültig |
TAB_CTR_DRL
Dimensions: 7 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
INIT |
| 0x01 |
OFF_DRL |
| 0x02 |
ON_DRL |
| 0x06 |
DRL_L_ON_R_ERR |
| 0x0A |
DRL_L_ERR_R_ON |
| 0x0D |
DRL_L_ERR_R_ERR |
| 0x0F |
Signal ungültig |
TAB_CTR_FMH
Dimensions: 4 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
INIT |
| 0x01 |
OFF_FMH |
| 0x02 |
ON_FMH |
| 0x03 |
Signal ungültig |
TAB_CTR_FOG_LAMP
Dimensions: 8 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
INIT |
| 0x01 |
OFF_RFLI_OFF_TRM |
| 0x02 |
ON_RFLI_OFF_TRM |
| 0x03 |
ON_RFLI_ON_TRM |
| 0x04 |
OFF_RFLI_ON_TRM |
| 0x08 |
ON_RFLI_SYNC |
| 0x09 |
ON_RFLI_ASYNC |
| 0xFF |
Signal ungültig |
TAB_CTR_FREQ_IDC
Dimensions: 8 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
Nicht_blinken |
| 0x01 |
Normal_Blinktakt |
| 0x02 |
Doppelter_Blinktakt |
| 0x03 |
Doppel_Blink_Impuls |
| 0x04 |
Spar_Blinktakt |
| 0x0D |
Reserviert_nicht_verfuegbar |
| 0x0E |
Reserviert_Fehler |
| 0x0F |
Signal unbefüllt |
TAB_CTR_GBL
Dimensions: 7 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
INIT |
| 0x01 |
OFF_GBL |
| 0x02 |
OFF_GBL_HARD |
| 0x03 |
GBL_MODE_1 |
| 0x0D |
Reserviert nicht verfügbar |
| 0x0E |
Reserviert Fehler |
| 0x0F |
Signal unbefüllt |
TAB_CTR_PLI
Dimensions: 5 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
INIT |
| 0x01 |
OFF_PLI |
| 0x02 |
ON_PLI_L |
| 0x03 |
ON_PLI_R |
| 0x0F |
Signal ungültig |
TAB_CTR_POLI
Dimensions: 7 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
INIT |
| 0x01 |
OFF_POLI |
| 0x02 |
POLI_MODUS_1 |
| 0x03 |
POLI_MODUS_2 |
| 0x04 |
POLI_MODUS_3 |
| 0x05 |
POLI_MODUS_4 |
| 0x0F |
Signal ungültig |
TAB_CTR_REMLI
Dimensions: 5 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
INIT |
| 0x01 |
OFF_Remote-Light |
| 0x02 |
ON_Remote-Light_1 |
| 0x04 |
ON_Remote-Light_0 |
| 0x0F |
Signal ungültig |
TAB_CTR_RVLP
Dimensions: 5 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
INIT |
| 0x01 |
OFF |
| 0x02 |
ON |
| 0x03 |
ON_TRM |
| 0x0F |
Signal ungültig |
TAB_CTR_WELL
Dimensions: 10 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
INIT |
| 0x01 |
OFF_WELL |
| 0x02 |
OFF_WELL_HARD |
| 0x03 |
WELL_MODE_1 |
| 0x04 |
WELL_MODE_2 |
| 0x05 |
WELL_MODE_3 |
| 0x06 |
WELL_MODE_4 |
| 0x07 |
WELL_MODE_5 |
| 0x08 |
WELL_MODE_6 |
| 0x0F |
Signal ungültig |
TAB_FUNKTIONSTESTRLM_SEGMENTRESULT
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 0 |
Fehler erkannt |
| 1 |
Kein Fehler erkannt |
| 0xFF |
Wert ungültig |
TAB_HARDWARE_VARIANT
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 0 |
unbekannt |
| 1 |
SAE |
| 2 |
ECE |
TAB_RESET_ZAEHLER_LOESCHEN
Dimensions: 2 rows × 2 columns
| WERT |
TEXT |
| 1 |
Reset Zaehler |
| 2 |
Watchdog Zaehler |
TAB_RUECKLEUCHTEN_FUNKTION_ARG
Dimensions: 16 rows × 2 columns
| WERT |
TEXT |
| 0x01 |
Standlicht/ Position light |
| 0x02 |
Rueckfahrlicht/ Rverse light |
| 0x03 |
Nebelschlusslicht/ Fog light |
| 0x04 |
Bremslicht/ Brake light |
| 0x05 |
Parklicht/ Parking light |
| 0x06 |
SML |
| 0x07 |
Tagfahrlicht/ Day running light |
| 0x08 |
Fahrtrichtungsanzeiger/ Direction indicator |
| 0x09 |
Goodbye Light |
| 0x0A |
Welcome Light |
| 0x0B |
Heimleuchte/ Follow me home |
| 0x0C |
ESS Blinken |
| 0x0D |
DWA Blinken |
| 0x0E |
Panik Blinken |
| 0x0F |
Überfall Alarm |
| 0x10 |
Permanenter Fahrtrichtungsanzeiger (virtuelle Lichtfunktion für Zulassungszwecke) |
TAB_SUPPLIERINFO_FIELD
Dimensions: 64 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
Wert 0 |
| 0x1 |
Wert 1 |
| 0x2 |
Wert 2 |
| 0x3 |
Wert 3 |
| 0x4 |
Wert 4 |
| 0x5 |
Wert 5 |
| 0x6 |
Wert 6 |
| 0x7 |
Wert 7 |
| 0x8 |
Wert 8 |
| 0x9 |
Wert 9 |
| 0xA |
Wert 10 |
| 0xB |
Wert 11 |
| 0xC |
Wert 12 |
| 0xD |
Wert 13 |
| 0xE |
Wert 14 |
| 0xF |
Wert 15 |
| 0x10 |
Wert 16 |
| 0x11 |
Wert 17 |
| 0x12 |
Wert 18 |
| 0x13 |
Wert 19 |
| 0x14 |
Wert 20 |
| 0x15 |
Wert 21 |
| 0x16 |
Wert 22 |
| 0x17 |
Wert 23 |
| 0x18 |
Wert 24 |
| 0x19 |
Wert 25 |
| 0x1A |
Wert 26 |
| 0x1B |
Wert 27 |
| 0x1C |
Wert 28 |
| 0x1D |
Wert 29 |
| 0x1E |
Wert 30 |
| 0x1F |
Wert 31 |
| 0x20 |
Wert 32 |
| 0x21 |
Wert 33 |
| 0x22 |
Wert 34 |
| 0x23 |
Wert 35 |
| 0x24 |
Wert 36 |
| 0x25 |
Wert 37 |
| 0x26 |
Wert 38 |
| 0x27 |
Wert 39 |
| 0x28 |
Wert 40 |
| 0x29 |
Wert 41 |
| 0x2A |
Wert 42 |
| 0x2B |
Wert 43 |
| 0x2C |
Wert 44 |
| 0x2D |
Wert 45 |
| 0x2E |
Wert 46 |
| 0x2F |
Wert 47 |
| 0x30 |
Wert 48 |
| 0x31 |
Wert 49 |
| 0x32 |
Wert 50 |
| 0x33 |
Wert 51 |
| 0x34 |
Wert 52 |
| 0x35 |
Wert 53 |
| 0x36 |
Wert 54 |
| 0x37 |
Wert 55 |
| 0x38 |
Wert 56 |
| 0x39 |
Wert 57 |
| 0x3A |
Wert 58 |
| 0x3B |
Wert 59 |
| 0x3C |
Wert 60 |
| 0x3D |
Wert 61 |
| 0x3E |
Wert 62 |
| 0xFF |
Wert ungültig |
UWB_TAB_ALIVE_CRC_0X1A1_V_VEH
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Alive-Fehler |
| 2 |
CRC-Fehler |
| 0xFF |
Wert ungültig |
UWB_TAB_ALIVE_CRC_0X1E4_CTR_LP_EX_2
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Alive-Fehler |
| 2 |
CRC-Fehler |
| 0xFF |
Wert ungültig |
UWB_TAB_ALIVE_CRC_0X215_ST_LP_EX_REAR
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Alive-Fehler |
| 2 |
CRC-Fehler |
| 0xFF |
Wert ungültig |
UWB_TAB_ALIVE_CRC_0X2EB_CTR_LP_EX
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Alive-Fehler |
| 2 |
CRC-Fehler |
| 0xFF |
Wert ungültig |
UWB_TAB_ALIVE_CRC_0X328_RELATIVZEIT
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Alive-Fehler |
| 2 |
CRC-Fehler |
| 0xFF |
Wert ungültig |
UWB_TAB_ALIVE_CRC_0X32_ST_CENG
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Alive-Fehler |
| 2 |
CRC-Fehler |
| 0xFF |
Wert ungültig |
UWB_TAB_ALIVE_CRC_0X330_KILOMETERSTAND
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Alive-Fehler |
| 2 |
CRC-Fehler |
| 0xFF |
Wert ungültig |
UWB_TAB_ALIVE_CRC_0X380_FAHRGESTELLNUMMER
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Alive-Fehler |
| 2 |
CRCFehler |
| 0xFF |
Wert ungültig |
UWB_TAB_ALIVE_CRC_0X388_FAHRZEUGTYP
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Alive-Fehler |
| 2 |
CRC-Fehler |
| 0xFF |
Wert ungültig |
UWB_TAB_ALIVE_CRC_0X3A0_FZZSTD
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Alive-Fehler |
| 2 |
CRC-Fehler |
| 0xFF |
Wert ungültig |
UWB_TAB_ALIVE_CRC_0X3C_CON_VEH
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Alive-Fehler |
| 2 |
CRC-Fehler |
| 0xFF |
Wert ungültig |
UWB_TAB_ALIVE_CRC_0XCA_CTR_FN_IDC
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Alive-Fehler |
| 2 |
CRCFehler |
| 0xFF |
Wert ungültig |
UWB_TAB_ALIVE_CRC_0X2CA_A_TEMP
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Alive-Fehler |
| 2 |
CRC-Fehler |
| 0xFF |
Wert ungültig |
UWB_TAB_CONFIGURATION_DATA_INVALID
Dimensions: 5 rows × 2 columns
| WERT |
TEXT |
| 1 |
binning data |
| 2 |
supplier data |
| 3 |
pav data |
| 4 |
crc pav data |
| 0xFF |
Wert ungültig |
UWB_TAB_DEFEKT_ART_NOTLAUFAKTIVIERUNG
Dimensions: 4 rows × 2 columns
| WERT |
TEXT |
| 1 |
PLAUSIBILITY_CHECK_FAILURE |
| 2 |
FUSI_DATA_CRC_CHECK_FAILURE |
| 3 |
COMMUNICATION_ERRORS |
| 0xFF |
Wert ungültig |
UWB_TAB_DEFEKT_ART_NTC
Dimensions: 4 rows × 2 columns
| WERT |
TEXT |
| 1 |
Kurzschluss nach Masse |
| 2 |
Leitungsunterbrechung |
| 3 |
Kurzschluss nach VBat |
| 0xFF |
Wert ungültig |
UWB_TAB_DEFEKT_ART_STRANG
Dimensions: 8 rows × 2 columns
| WERT |
TEXT |
| 1 |
Kurzschluss nach Masse |
| 2 |
Kurzschluss nach Plus |
| 3 |
Spannung außerhalb Toleranz |
| 4 |
Strangunterbrechung |
| 5 |
Übertemperatur 1 (Abschaltung) |
| 6 |
Übertemperatur 2 (Degradation) |
| 7 |
Strom außerhalb Toleranz |
| 0xFF |
Wert ungültig |
UWB_TAB_FLS_ERROR_SOURCE
Dimensions: 7 rows × 2 columns
| WERT |
TEXT |
| 1 |
FLS_E_COMPARE_FAILED |
| 2 |
FLS_E_ERASE_FAILED |
| 3 |
FLS_E_READ_FAILED |
| 4 |
FLS_E_UNEXPECTED_FLASH_ID |
| 5 |
FLS_E_WRITE_FAILED |
| 6 |
FLS_E_READ_FAILED_DED |
| 0xFF |
Wert ungültig |
UWB_TAB_GPT_ERROR_SOURCE
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
GPT_E_TIMEOUT_FAILURE |
| 2 |
GPT_E_READBACK_FAILURE |
| 0xFF |
Wert ungültig |
UWB_TAB_MCU_ERROR_SOURCE
Dimensions: 4 rows × 2 columns
| WERT |
TEXT |
| 1 |
MCU_E_CLOCK_FAILURE |
| 2 |
MCU_E_WRITE_TIMEOUT_FAILURE |
| 3 |
MCU_E_LVI_FAILURE |
| 0xFF |
Wert ungültig |
UWB_TAB_NVM_ERROR_SOURCE
Dimensions: 8 rows × 2 columns
| WERT |
TEXT |
| 1 |
NVM_E_INTEGRITY_FAILED |
| 2 |
NVM_E_LOSS_OF_REDUNDANCY |
| 3 |
NVM_E_QUEUE_OVERFLOW |
| 4 |
NVM_E_REQ_FAILED |
| 5 |
NVM_E_VERIFY_FAILED |
| 6 |
NVM_E_WRITE_PROTECTED |
| 7 |
NVM_E_WRONG_BLOCK_ID |
| 0xFF |
Wert ungültig |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_1
Dimensions: 5 rows × 2 columns
| WERT |
TEXT |
| 0 |
Strang |
| 1 |
Segment 1 |
| 2 |
Segment 2 |
| 3 |
Segment 3 |
| 0xFF |
Wert ungültig |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_2
Dimensions: 5 rows × 2 columns
| WERT |
TEXT |
| 0 |
Strang |
| 4 |
Segment 4 |
| 5 |
Segment 5 |
| 6 |
Segment 6 |
| 0xFF |
Wert ungültig |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_3
Dimensions: 5 rows × 2 columns
| WERT |
TEXT |
| 0 |
Strang 3 |
| 7 |
Segment 7 |
| 8 |
Segment 8 |
| 9 |
Segment 9 |
| 0xFF |
Wert ungültig |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_4
Dimensions: 5 rows × 2 columns
| WERT |
TEXT |
| 0 |
Strang 4 |
| 10 |
Segment 10 |
| 11 |
Segment 11 |
| 12 |
Segment 12 |
| 0xFF |
Wert ungültig |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_5
Dimensions: 4 rows × 2 columns
| WERT |
TEXT |
| 0 |
Strang 5 |
| 13 |
Segment 13 |
| 14 |
Segment 14 |
| 0xFF |
Wert ungültig |
UWB_TAB_OVERVOLTAGE_SEG_STRANG_6
Dimensions: 8 rows × 2 columns
| WERT |
TEXT |
| 0 |
Strang 6 |
| 15 |
Segment 15 |
| 16 |
Segment 16 |
| 17 |
Segment 17 |
| 18 |
Segment 18 |
| 19 |
Segment 19 |
| 20 |
Segment 20 |
| 0xFF |
Wert ungültig |
UWB_TAB_SIGNAL_0X1A1_V_VEH
Dimensions: 6 rows × 2 columns
| WERT |
TEXT |
| 1 |
DVCO_VEH |
| 2 |
QU_V_VEH_COG |
| 3 |
V_VEH_COG |
| 4 |
ALIV_V_VEH |
| 5 |
CRC_V_VEH |
| 0xFF |
Wert ungültig |
UWB_TAB_SIGNAL_0X1E4_CTR_LP_EX_2
Dimensions: 13 rows × 2 columns
| WERT |
TEXT |
| 1 |
CTR_FN_ML |
| 2 |
CTR_FN_FFLI |
| 3 |
CTR_FN_OVT |
| 4 |
CTR_FN_MAB |
| 5 |
CTR_MOD_FN_SPFLS |
| 6 |
CTR_PHA_FN_SPFLS |
| 7 |
CTR_FN_CORNL_RH |
| 8 |
CTR_FN_CORNL_LH |
| 9 |
CTR_LDSTR_LOWB_RH |
| 10 |
CTR_FN_DIPB_RH |
| 11 |
CTR_LDSTR_LOWB_LH |
| 12 |
CTR_FN_DIPB_LH |
| 0xFF |
Wert ungültig |
UWB_TAB_SIGNAL_0X215_REAR_2
Dimensions: 16 rows × 2 columns
| WERT |
TEXT |
| 1 |
ST_SU_REAR_2_LH |
| 2 |
ST_FN_IDC_REAR_2_LH |
| 3 |
ST_FN_FMH_REAR_2_LH |
| 4 |
ST_FN_REMLI_REAR_2_LH |
| 5 |
ST_FN_BL_REAR_2_LH |
| 6 |
ST_FN_DRL_REAR_2_LH |
| 7 |
ST_FN_BFD_REAR_2_LH |
| 8 |
ST_FN_RVLP_REAR_2_LH |
| 9 |
ST_FN_PLI_REAR_2_LH |
| 10 |
ST_FN_POLI_REAR_2_LH |
| 11 |
ST_FN_RFLP_REAR_2_LH |
| 12 |
ST_FN_WELL_REAR_2_LH |
| 13 |
CHL_ST_LP_EX_REAR_2_LH |
| 14 |
ALIV_ST_LP_EX_REAR_2_LH |
| 15 |
CRC_ST_LP_EX_REAR_2_LH |
| 0xFF |
Wert ungültig |
UWB_TAB_SIGNAL_0X2CB_CTRL_LP_EX
Dimensions: 15 rows × 2 columns
| WERT |
TEXT |
| 1 |
CTR_FN_REMLI |
| 2 |
CTR_FN_FMH |
| 3 |
CTR_FN_BL |
| 4 |
CTR_FN_DRL |
| 5 |
CTR_FN_BFD |
| 6 |
CTR_FN_RVLP |
| 7 |
CTR_FN_PLI |
| 8 |
CTR_FN_POLI |
| 9 |
CTR_FN_RFLP |
| 10 |
CTR_FN_WELL |
| 11 |
CTR_BRIGLEV_LP |
| 12 |
ALIV_CTR_LP_EX |
| 13 |
CRC_CTR_LP_EX |
| 14 |
CTR_FN_GBL |
| 0xFF |
Wert ungültig |
UWB_TAB_SIGNAL_0X328_RELATIVZEIT
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
T_DAY_COU_ABSL |
| 2 |
T_SEC_COU_REL |
| 0xFF |
Wert ungültig |
UWB_TAB_SIGNAL_0X32_ST_CENG
Dimensions: 4 rows × 2 columns
| WERT |
TEXT |
| 1 |
ST_ENERG_SUPY |
| 2 |
ST_UDP |
| 3 |
ST_CENG_DRV |
| 0xFF |
Wert ungültig |
UWB_TAB_SIGNAL_0X388_FAHRZEUGTYP
Dimensions: 5 rows × 2 columns
| WERT |
TEXT |
| 1 |
TYP_CNT |
| 2 |
TYP_STE |
| 3 |
QUAN_GR |
| 4 |
TYP_VEH |
| 0xFF |
Wert ungültig |
UWB_TAB_SIGNAL_0X3A0_FZZSTD
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
ST_ILK_ERRM_FZM |
| 2 |
ST_ERRM_FZM |
| 0xFF |
Wert ungültig |
UWB_TAB_SIGNAL_0X3C_CON_VEH
Dimensions: 7 rows × 2 columns
| WERT |
TEXT |
| 1 |
QU_ST_CON_VEH |
| 2 |
ST_CON_VEH |
| 3 |
CTR_FKTN_PRINT |
| 4 |
CTR_BS_PRINT |
| 5 |
ALIV_CON_VEH |
| 6 |
CRC_CON_VEH |
| 0xFF |
Wert ungültig |
UWB_TAB_SIGNAL_0XCA_CTR_FN_IDC
Dimensions: 11 rows × 2 columns
| WERT |
TEXT |
| 1 |
OVLY_FN_IDC |
| 2 |
ACV_FN_IDC |
| 3 |
CTR_IDC |
| 4 |
CTR_SYNC_IDC |
| 5 |
CTR_FREQ_IDC |
| 6 |
CHL_CTR_FN_IDC |
| 7 |
ALIV_CTR_FNS_IDC |
| 8 |
CRC_CTR_FNS_IDC |
| 9 |
CTR_T_SECS_IDC |
| 10 |
CTR_T_MSECS_IDC |
| 0xFF |
Wert ungültig |
UWB_TAB_SIGNAL_0X2CA_A_TEMP
Dimensions: 2 rows × 2 columns
| WERT |
TEXT |
| 1 |
TEMP_EX |
| 0xFF |
Wert ungültig |
UWB_TAB_SIGNAL_0X330_KILOMETERSTAND
Dimensions: 2 rows × 2 columns
| WERT |
TEXT |
| 1 |
MILE_KM |
| 0xFF |
Wert ungültig |
UWB_TAB_SIGNAL_0X380_FAHRGESTELLNUMMER
Dimensions: 8 rows × 2 columns
| WERT |
TEXT |
| 1 |
NO_VECH_1 |
| 2 |
NO_VECH_2 |
| 3 |
NO_VECH_3 |
| 4 |
NO_VECH_4 |
| 5 |
NO_VECH_5 |
| 6 |
NO_VECH_6 |
| 7 |
NO_VECH_7 |
| 0xff |
Wert ungültig |
UWB_TAB_TIMEOUT_0X1A1_V_VEH
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Timeout zyklisch |
| 2 |
Timeout Ereignisgesteuert |
| 0xFF |
Wert ungültig |
UWB_TAB_TIMEOUT_0X1E4_CTR_LP_EX_2
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Timeout zyklisch |
| 2 |
Timeout Ereignisgesteuert |
| 0xFF |
Wert ungültig |
UWB_TAB_TIMEOUT_0X215_ST_LP_EX_REAR
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Timeout zyklisch |
| 2 |
Timeout Ereignisgesteuert |
| 0xFF |
Wert ungültig |
UWB_TAB_TIMEOUT_0X328_RELATIVZEIT
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Timeout zyklisch |
| 2 |
Timeout Ereignisgesteuer |
| 0xFF |
Wert ungültig |
UWB_TAB_TIMEOUT_0X32_ST_CENG
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Timeout zyklisch |
| 2 |
Timeout Ereignisgesteuert |
| 0xFF |
Wert ungültig |
UWB_TAB_TIMEOUT_0X330_KILOMETERSTAND
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Timeout zyklisch |
| 2 |
Timeout Ereignisgesteuert |
| 0xFF |
Wert ungültig |
UWB_TAB_TIMEOUT_0X380_FAHRGESTELLNUMMER
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Timeout zyklisch |
| 2 |
Timeout Ereignisgesteuert |
| 0xFF |
Wert ungültig |
UWB_TAB_TIMEOUT_0X388_FAHRZEUGTYP
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Timeout zyklisch |
| 2 |
Timeout Ereignisgesteuert |
| 0xFF |
Wert ungültig |
UWB_TAB_TIMEOUT_0X3A0_FZZSTD
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Timeout zyklisch |
| 2 |
Timeout Ereignisgesteuert |
| 0xFF |
Wert ungültig |
UWB_TAB_TIMEOUT_0X3C_CON_VEH
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Timeout zyklisch |
| 2 |
Timeout Ereignisgesteuert |
| 0xFF |
Wert ungültig |
UWB_TAB_TIMEOUT_0X2CA_A_TEMP
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Timeout zyklisc |
| 2 |
Timeout Ereignisgesteuert |
| 0xFF |
Wert ungültig |
UWB_TAB_TIMEOUT_0X2EB_CTR_LP_EX
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Timeout zyklisch |
| 2 |
Timeout Ereignisgesteuert |
| 0xFF |
Wert ungültig |
UWB_TAB_TIMEOUT_0X2FC_STAT_ZV_KLAPPEN
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Timeout zyklisch |
| 2 |
Timeout Ereignisgesteuert |
| 0xFF |
Wert ungültig |
UWB_TAB_TIMEOUT_CRC_0XCA_CTR_FN_IDC
Dimensions: 3 rows × 2 columns
| WERT |
TEXT |
| 1 |
Timeout zyklisch |
| 2 |
Timeout Ereignisgesteuer |
| 0xFF |
Wert ungültig |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_1
Dimensions: 5 rows × 2 columns
| WERT |
TEXT |
| 0 |
Strang 0 |
| 1 |
Segment 1 |
| 2 |
Segment 2 |
| 3 |
Segment 3 |
| 0xFF |
Wert ungültig |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_2
Dimensions: 5 rows × 2 columns
| WERT |
TEXT |
| 0 |
strang 2 |
| 4 |
segment 4 |
| 5 |
segment 5 |
| 6 |
segment 6 |
| 0xFF |
Wert ungültig |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_3
Dimensions: 5 rows × 2 columns
| WERT |
TEXT |
| 0 |
strang 3 |
| 7 |
segment 7 |
| 8 |
segment 8 |
| 9 |
segment 9 |
| 0xFF |
Wert ungültig |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_4
Dimensions: 5 rows × 2 columns
| WERT |
TEXT |
| 0 |
strang 4 |
| 10 |
segment 10 |
| 11 |
segment 11 |
| 12 |
segment 12 |
| 0xFF |
Wert ungültig |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_5
Dimensions: 4 rows × 2 columns
| WERT |
TEXT |
| 0 |
strang 5 |
| 13 |
segment 13 |
| 14 |
segment 14 |
| 0xFF |
Wert ungültig |
UWB_TAB_UNDERVOLTAGE_SEG_STRANG_6
Dimensions: 8 rows × 2 columns
| WERT |
TEXT |
| 0 |
strang 6 |
| 15 |
segment 15 |
| 16 |
segment 16 |
| 17 |
segment 17 |
| 18 |
segment 18 |
| 19 |
segment 19 |
| 20 |
segment 20 |
| 0xFF |
Wert ungültig |
UWB_TAB_WDGM_ERROR_SOURCE
Dimensions: 4 rows × 2 columns
| WERT |
TEXT |
| 1 |
WDGM_E_IMPROPER_CALLER |
| 2 |
WDGM_E_MONITORING |
| 3 |
WDGM_E_SET_MODE |
| 0xFF |
Wert ungültig |
UWB_TAB_WDG_ERROR_SOURCE
Dimensions: 5 rows × 2 columns
| WERT |
TEXT |
| 1 |
WDG_E_DISABLE_REJECTED |
| 2 |
WDG_E_MODE_FAILED |
| 3 |
WDG_E_TRIGGER_TIMEOUT |
| 4 |
WDG_E_READBACK_FAILURE |
| 0xFF |
Wert ungültig |