Skip to content

SCR03.prg

INFO

Field Value
ECU Selective Catalytic Reduction
ORIGIN BMW EA-722 Philipp_Wolfgramm
REVISION 9.000
AUTHOR BMW EA-722 Wolfgramm
COMMENT -
PACKAGE 1.992
SPRACHE deutsch

Jobs

Index

  • INFO - Information SGBD
  • INITIALISIERUNG - Initialisierung und Kommunikationsparameter
  • IDENT - Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
  • FS_LESEN - Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
  • FS_LESEN_DETAIL - Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
  • FS_LOESCHEN - Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
  • PRUEFSTEMPEL_LESEN - Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
  • PRUEFSTEMPEL_SCHREIBEN - Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
  • SVK_LESEN - Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
  • STATUS_LESEN - Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
  • STEUERN - Vorgeben eines Status UDS : $2E WriteDataByIdentifier
  • SERIENNUMMER_LESEN - Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
  • STEUERN_IO - Vorgeben eines Status UDS : $2F InputOutputControlByIdentifier
  • STEUERN_ROUTINE - Vorgeben eines Status UDS : $31 RoutineControl
  • FS_SPERREN - Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
  • FS_LESEN_PERMANENT - permanente Fehler aus Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $15 ReportDTCWithPermanentStatus Modus: Default
  • IS_LESEN - Sekundaerer Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $22 ReadDataByIdentifierRequestServiceID UDS : $2000 DataIdentifier sekundaerer Fehlerspeicher Modus: Default
  • IS_LESEN_DETAIL - sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $22 ReadDataByIdentifier UDS : $20 dataIdentifier UDS : $00 alle Info-Meldungen anschließend UDS : $20 dataIdentifier UDS : $nn Details zur Info-Meldung an der Position n Modus: Default
  • IS_LOESCHEN - Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default
  • HERSTELLINFO_LESEN - Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
  • DIAGNOSE_AUFRECHT - Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
  • DIAGNOSE_MODE - SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
  • SLEEP_MODE - SG in Sleep-Mode versetzen UDS : $11 ECUReset UDS : $04 EnableRapidPowerShutDown Modus: Default
  • ENERGIESPARMODE - Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
  • STATUS_ENERGIESPARMODE - Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
  • STATUS_BETRIEBSMODE - Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default
  • STEUERN_BETRIEBSMODE - Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default
  • STEUERGERAETE_RESET - Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
  • STATUS_ROE_REPORT - Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS: $86 ResponseOnEvent $04 report activated events $02 eventWindowTime - infinite (LH Diagnosemaster V11 oder höher, Umsetzung nach LH V6 - V10 wird jedoch toleriert)
  • STEUERN_ROE_PERSISTENT_STOP - Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
  • STEUERN_ROE_PERSISTENT_START - Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
  • CALID_CVN_LESEN - OBD Calibration ID, CVN Calibration verification number UDS : $22 ReadDataByIdentifier UDS : $2541 CAL-ID Calibration ID and CVN Calibration verification number

INFO

Information SGBD

No arguments.

Results

Name Type Comment
ECU string Steuergerät im Klartext
ORIGIN string Steuergeräte-Verantwortlicher
REVISION string Versions-Nummer
AUTHOR string Namen aller Autoren
COMMENT string wichtige Hinweise
PACKAGE string Include-Paket-Nummer
SPRACHE string deutsch, english

INITIALISIERUNG

Initialisierung und Kommunikationsparameter

No arguments.

Results

Name Type Comment
DONE int 1, wenn Okay

IDENT

Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default

No arguments.

Results

Name Type Comment
ID_SG_ADR long Steuergeraeteadresse
ID_SGBD_INDEX long Index zur Erkennung der SG-Variante
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

FS_LESEN

Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default

Arguments

Name Type Comment
FEHLER_KLASSE string 'IGNORIERE_EREIGNIS_DTC': Wenn EREIGNIS_DTC = '1', DTC-Fehlereinträge werden ignoriert sonst: FEHLERKLASSE wird ausgewertet

Results

Name Type Comment
F_VERSION int Typ des Fehlerspeichers Fuer UDS immer 3
F_HEX_CODE binary Fehlerdaten pro Fehler als Hexcode
F_ORT_NR long Index fuer Fehlerort
F_ORT_TEXT string Fehlerort als Text table FOrtTexte ORTTEXT
F_EREIGNIS_DTC int 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC -1: wird nicht unterstuetzt table FOrtTexte EREIGNIS_DTC
F_FEHLERKLASSE unsigned long table FOrtTexte FEHLERKLASSE
F_STATUSBYTE int Wert des DTC-Statusbyte laut ISO 14229 (bitcodiert) Bedeutung der einzelnen Bits: Bit 7: warningIndicatorRequested Bit 6: testNotCompletedThisOperationCycle Bit 5: testFailedSinceLastClear Bit 4: testNotCompletedSinceLastClear Bit 3: ConfirmedDTC Bit 2: PendingDTC Bit 1: testFailedThisOperationCycle Bit 0: testFailed
F_READY_NR int Readyness Flag (Standard-Fehlerart) als Zahl
F_READY_TEXT string Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
F_VORHANDEN_NR int Fehler vorhanden (Standard-Fehlerart) als Zahl
F_VORHANDEN_TEXT string Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
F_WARNUNG_NR int Warnlampen Flag (Standard-Fehlerart) als Zahl
F_WARNUNG_TEXT string Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

FS_LESEN_DETAIL

Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default

Arguments

Name Type Comment
F_CODE long gewaehlter Fehlercode

Results

Name Type Comment
F_VERSION int Typ des Fehlerspeichers Fuer UDS immer 3
F_HEX_CODE binary Fehlerdaten pro Fehler als Hexcode
F_ORT_NR long Index fuer Fehlerort
F_ORT_TEXT string Fehlerort als Text table FOrtTexte ORTTEXT
F_EREIGNIS_DTC int 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC
F_STATUSBYTE int Wert des DTC-Statusbyte laut ISO 14229 (bitcodiert) Bedeutung der einzelnen Bits: Bit 7: warningIndicatorRequested Bit 6: testNotCompletedThisOperationCycle Bit 5: testFailedSinceLastClear Bit 4: testNotCompletedSinceLastClear Bit 3: ConfirmedDTC Bit 2: PendingDTC Bit 1: testFailedThisOperationCycle Bit 0: testFailed
F_READY_NR int Readyness Flag (Standard-Fehlerart) als Zahl
F_READY_TEXT string Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
F_VORHANDEN_NR int Fehler vorhanden (Standard-Fehlerart) als Zahl
F_VORHANDEN_TEXT string Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
F_WARNUNG_NR int Warnlampen Flag (Standard-Fehlerart) als Zahl
F_WARNUNG_TEXT string Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
F_HFK int Haeufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf
F_HLZ int Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Heilungsszaehler
F_UEBERLAUF int 0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers
F_FEHLERKLASSE_NR int 0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich !
F_FEHLERKLASSE_TEXT string Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT
F_UW_ANZ int Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung
F_UW_KM long Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht
F_UW_KM_SUPREME string Umweltbedingung Kilometerstand metergenau (31 Bit) Wertebereich: 0 - 16777215 km
F_UW_KM_SUPREME_INSYNC unsigned char Environmental condition mileage (long, LSb 1 Bit) 0 == out of sync, 1 == insync
F_UW_ZEIT long Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht
F_UW_ZEIT_MS int Umweltbedingung Zeit Millisekundenanteil Genauigkeit: in 5ms-Schritten -1, wenn Absolute Zeit nicht zur Verfuegung steht
F_UW_ZEIT_SUPREME string Umweltbedingung Absolute Zeit mit Sekundenbruchteilen Genauigkeit: in 5ms-Schritten wenn Zeit nicht zur Verfuegung steht "No time received"
F_UW_ZEIT_SUPREME_INSYNC unsigned char Environmental condition system time (Bit0) 0 == out of sync, 1 == insync
F_UW_ZEIT_SUPREME_SYNCMETHOD unsigned char Environmental condition system time (Bit1 und Bit2) 00 == Kombizeit, 01 == DMCS, 10 == IEEE802.1AS, 11 == invalid
F_UW_ZEIT_SUPREME_SYNCMETHOD_INFO string Environmental condition system time (Bit1 und Bit2) table: 0 == Kombizeit, 1 == DMCS, 2 == IEEE802.1AS, 3 == invalid
F_UW_ZEIT_SUPREME_USER_INFORMATION string Environmental condition system time (Bit0, Bit1 und Bit2) TAB_ZEIT_USER_INFO
F_UW_BN int Umweltbedingung Basisnetz (1 Byte) -1, wenn Daten bzgl. Basisnetz nicht zur Verfuegung stehen
F_UW_TN long Umweltbedingung Teilnetz (3 Byte) -1, wenn Daten bzgl. funktionalem Teilnetz nicht zur Verfuegung stehen
F_SAE_CODE unsigned int Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD
F_SAE_CODE_STRING string 5 stelliger Text in der Form 'Sxxxx'
F_SAE_CODE_TEXT string Text zu F_SAE_CODE
_RESPONSE_SNAPSHOT binary Hex-Antwort von SG
_RESPONSE_EXTENDED_DATA binary Hex-Antwort von SG
_RESPONSE_SEVERITY binary Hex-Antwort von SG
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT

FS_LOESCHEN

Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default

Arguments

Name Type Comment
F_CODE long 0x??????: Angabe eines einzelnen Fehlers Default: 0xFFFFFF: alle Fehler

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

PRUEFSTEMPEL_LESEN

Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default

No arguments.

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
BYTE1 int Bereich: 0-255 bzw. 0x00-0xFF
BYTE2 int Bereich: 0-255 bzw. 0x00-0xFF
BYTE3 int Bereich: 0-255 bzw. 0x00-0xFF
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

PRUEFSTEMPEL_SCHREIBEN

Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default

Arguments

Name Type Comment
BYTE1 int Bereich: 0-255 bzw. 0x00-0xFF
BYTE2 int Bereich: 0-255 bzw. 0x00-0xFF
BYTE3 int Bereich: 0-255 bzw. 0x00-0xFF

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

SVK_LESEN

Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default

Arguments

Name Type Comment
SVK string table SVK_ID BEZEICHNUNG WERT default SVK_AKTUELL

Results

Name Type Comment
PROG_TEST int Programmierabhaengigkeiten (ProgrammingDependenciesChecked) 1: IO : Signaturpruefung und ProgrammingDependenciesCheck erfolgreich 2: NIO: mindestens eine SWE fehlerhaft oder ProgrammingDependenciesCheck nicht durchgefuehrt 3: NIO: mindestens eine SWE passt nicht mit einer HWE zusammen 4: NIO: mindestens eine SWE passt nicht mit einer anderen SWE zusammen sonst: reserviert
ANZAHL_EINHEITEN int Anzahl der xWEn
PROG_DATUM string Programmierdatum (DD.MM.YY)
PROG_KM long KM-Stand bei Programmierung (10 KM bis 655350 KM) Inkrement sind 10 KM -1: KM-Stand wird nicht unterstuetzt
PROZESSKLASSE_WERT int table Prozessklassen WERT dezimale Angabe der Prozessklasse
PROZESSKLASSE_TEXT string table Prozessklassen BEZEICHNUNG Text-Angabe der Prozessklasse
PROZESSKLASSE_KURZTEXT string table Prozessklassen PROZESSKLASSE Text-Angabe des Prozessklassenkurztextes
SGBM_IDENTIFIER string Angabe SGBM-ID der Prozessklasse
VERSION string Angabe der Version der Prozessklasse
SGBM_ID string Angabe von Prozessklasse, SGBM-Identifier, Version
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STATUS_LESEN

Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier

Arguments

Name Type Comment
ARGUMENT_SPALTE string 'ARG', 'ID', 'LABEL'
STATUS string Es muss mindestens ein Argument übergeben werden Es wird das zugehörige result erzeugt table SG_Funktionen ARG ID RESULTNAME RES_TABELLE ARG_TABELLE

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Antwort von SG
_RESPONSE binary Hex-Antwort von SG

STEUERN

Vorgeben eines Status UDS : $2E WriteDataByIdentifier

Arguments

Name Type Comment
ARGUMENT_SPALTE string 'ARG', 'ID', 'LABEL'
STATUS string Siehe table SG_Funktionen ARG ID LABEL ARG_TABELLE
WERT string Es muss mindestens ein Argument übergeben werden Argumente siehe table SG_Funktionen ARG ID ARG_TABELLE

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Antwort von SG
_RESPONSE binary Hex-Antwort von SG

SERIENNUMMER_LESEN

Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default

No arguments.

Results

Name Type Comment
SERIENNUMMER string Seriennummer des Steuergeraets
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STEUERN_IO

Vorgeben eines Status UDS : $2F InputOutputControlByIdentifier

Arguments

Name Type Comment
ARGUMENT_SPALTE string 'ARG', 'ID', 'LABEL'
STATUS string Siehe table SG_Funktionen ARG ID RES_TABELLE ARG_TABELLE
STEUERPARAMETER string 'RCTECU' = returnControlToECU 'RTD' = resetToDefault 'FCS' = freezeCurrentState 'STA' = shortTermAdjustment optionales Argument Wenn nicht angegeben, dann kein InputOutputControlParameter im Request
WERT string Argumente siehe table SG_Funktionen ARG_TABELLE

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Antwort von SG
_RESPONSE binary Hex-Antwort von SG

STEUERN_ROUTINE

Vorgeben eines Status UDS : $31 RoutineControl

Arguments

Name Type Comment
ARGUMENT_SPALTE string 'ARG', 'ID', 'LABEL'
STATUS string Siehe table SG_Funktionen ARG ID RES_TABELLE ARG_TABELLE
STEUERPARAMETER string 'STR' = startRoutine 'STPR' = stopRoutine 'RRR' = requestRoutineResults
WERT string Argumente siehe table SG_Funktionen ARG_TABELLE

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Antwort von SG
_RESPONSE binary Hex-Antwort von SG

FS_SPERREN

Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default

Arguments

Name Type Comment
SPERREN string "ja" -> Fehlerspeicher sperren "nein" -> Fehlerspeicher freigeben table DigitalArgument TEXT Default: "ja"

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

FS_LESEN_PERMANENT

permanente Fehler aus Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $15 ReportDTCWithPermanentStatus Modus: Default

No arguments.

Results

Name Type Comment
F_VERSION int Typ des Fehlerspeichers fuer UDS immer 3
F_HEX_CODE binary Fehlerdaten pro Fehler als Hexcode
F_ORT_NR long Index fuer Fehlerort
F_ORT_TEXT string Fehlerort als Text table FOrtTexte ORTTEXT
F_EREIGNIS_DTC int 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC
F_READY_NR int Readyness Flag (Standard-Fehlerart) als Zahl
F_READY_TEXT string Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
F_VORHANDEN_NR int Fehler vorhanden (Standard-Fehlerart) als Zahl
F_VORHANDEN_TEXT string Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
F_WARNUNG_NR int Warnlampen Flag (Standard-Fehlerart) als Zahl
F_WARNUNG_TEXT string Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

IS_LESEN

Sekundaerer Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $22 ReadDataByIdentifierRequestServiceID UDS : $2000 DataIdentifier sekundaerer Fehlerspeicher Modus: Default

No arguments.

Results

Name Type Comment
F_VERSION int Typ des Fehlerspeichers Fuer UDS immer 3
F_HEX_CODE binary Fehlerdaten pro Fehler als Hexcode
F_ORT_NR long Index fuer Fehlerort
F_ORT_TEXT string Fehlerort als Text table FOrtTexte ORTTEXT
F_EREIGNIS_DTC int 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC
F_STATUSBYTE int Wert des DTC-Statusbyte laut ISO 14229 (bitcodiert) Bedeutung der einzelnen Bits: Bit 7: warningIndicatorRequested Bit 6: testNotCompletedThisOperationCycle Bit 5: testFailedSinceLastClear Bit 4: testNotCompletedSinceLastClear Bit 3: ConfirmedDTC Bit 2: PendingDTC Bit 1: testFailedThisOperationCycle Bit 0: testFailed
F_READY_NR int Readyness Flag (Standard-Fehlerart) als Zahl
F_READY_TEXT string Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
F_VORHANDEN_NR int Fehler vorhanden (Standard-Fehlerart) als Zahl
F_VORHANDEN_TEXT string Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
F_WARNUNG_NR int Warnlampen Flag (Standard-Fehlerart) als Zahl
F_WARNUNG_TEXT string Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

IS_LESEN_DETAIL

sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $22 ReadDataByIdentifier UDS : $20 dataIdentifier UDS : $00 alle Info-Meldungen anschließend UDS : $20 dataIdentifier UDS : $nn Details zur Info-Meldung an der Position n Modus: Default

Arguments

Name Type Comment
F_CODE long gewaehlter Infocode Wenn dieser Parameter angegeben wird, wird die Position automatisch ermittelt. Es darf dann nicht argument F_POS angegeben werden
F_POS int gewaehlter Eintrag Wenn dieser Parameter angegeben wird, wird die Position benutzt. Wertebereich 1 - 255 Es darf dann nicht argument F_CODE angegeben werden

Results

Name Type Comment
F_VERSION int Typ des Fehlerspeichers Fuer UDS immer 3
F_HEX_CODE binary Fehlerdaten pro Fehler als Hexcode
F_ORT_NR long Index fuer Fehlerort
F_ORT_TEXT string Fehlerort als Text table FOrtTexte ORTTEXT
F_EREIGNIS_DTC int 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC
F_STATUSBYTE int Wert des DTC-Statusbyte laut ISO 14229 (bitcodiert) Bedeutung der einzelnen Bits: Bit 7: warningIndicatorRequested Bit 6: testNotCompletedThisOperationCycle Bit 5: testFailedSinceLastClear Bit 4: testNotCompletedSinceLastClear Bit 3: ConfirmedDTC Bit 2: PendingDTC Bit 1: testFailedThisOperationCycle Bit 0: testFailed
F_READY_NR int Readyness Flag (Standard-Fehlerart) als Zahl
F_READY_TEXT string Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
F_VORHANDEN_NR int Fehler vorhanden (Standard-Fehlerart) als Zahl
F_VORHANDEN_TEXT string Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
F_WARNUNG_NR int Warnlampen Flag (Standard-Fehlerart) als Zahl
F_WARNUNG_TEXT string Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
F_HFK int Haeufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf
F_HLZ int Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Heilungsszaehler
F_UEBERLAUF int 0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers
F_FEHLERKLASSE_NR int 0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich !
F_FEHLERKLASSE_TEXT string Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT
F_UW_ANZ int Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung
F_UW_KM long Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht
F_UW_KM_SUPREME string Umweltbedingung Kilometerstand metergenau (31 Bit) Wertebereich: 0 - 16777215 km
F_UW_KM_SUPREME_INSYNC unsigned char Environmental condition mileage (long, LSb 1 Bit) 0 == out of sync, 1 == insync
F_UW_ZEIT long Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht
F_UW_ZEIT_MS int Umweltbedingung Zeit Millisekundenanteil Genauigkeit: in 5ms-Schritten -1, wenn Absolute Zeit nicht zur Verfuegung steht
F_UW_ZEIT_SUPREME string Umweltbedingung Absolute Zeit mit Sekundenbruchteilen Genauigkeit: in 5ms-Schritten wenn Zeit nicht zur Verfuegung steht "No time received"
F_UW_ZEIT_SUPREME_INSYNC unsigned char Environmental condition system time (Bit0) 0 == out of sync, 1 == insync
F_UW_ZEIT_SUPREME_SYNCMETHOD unsigned char Environmental condition system time (Bit1 und Bit2) 00 == Kombizeit, 01 == DMCS, 10 == IEEE802.1AS, 11 == invalid
F_UW_ZEIT_SUPREME_SYNCMETHOD_INFO string Environmental condition system time (Bit1 und Bit2) table: 0 == Kombizeit, 1 == DMCS, 2 == IEEE802.1AS, 3 == invalid
F_UW_ZEIT_SUPREME_USER_INFORMATION string Environmental condition system time (Bit0, Bit1 und Bit2) TAB_ZEIT_USER_INFO
F_UW_BN int Umweltbedingung Basisnetz (1 Byte) -1, wenn Daten bzgl. Basisnetz nicht zur Verfuegung stehen
F_UW_TN long Umweltbedingung Teilnetz (3 Byte) -1, wenn Daten bzgl. funktionalem Teilnetz nicht zur Verfuegung stehen
F_SAE_CODE unsigned int Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD
F_SAE_CODE_STRING string 5 stelliger Text in der Form 'Sxxxx'
F_SAE_CODE_TEXT string Text zu F_SAE_CODE
_RESPONSE_2000 binary Hex-Antwort von SG
_RESPONSE_200X binary Hex-Antwort von SG
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT

IS_LOESCHEN

Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default

No arguments.

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

HERSTELLINFO_LESEN

Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default

No arguments.

Results

Name Type Comment
ID_LIEF_NR long Lieferantennummer 0xFFFFFF, falls nicht vorhanden
ID_LIEF_TEXT string Text zu ID_LIEF_NR table Lieferanten LIEF_TEXT unbekannter Hersteller, falls nicht vorhanden
ID_DATUM string Herstelldatum (DD.MM.YY)
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG
_REQUEST_2 binary Hex-Auftrag an SG
_RESPONSE_2 binary Hex-Antwort von SG

DIAGNOSE_AUFRECHT

Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default

Arguments

Name Type Comment
SG_ANTWORT string "ja" -> SG soll antworten "nein" -> SG soll nicht antworten table DigitalArgument TEXT Default: SG soll antworten

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

DIAGNOSE_MODE

SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job

Arguments

Name Type Comment
MODE string gewuenschter Diagnose-Modus table DiagMode MODE MODE_TEXT Defaultwert: DEFAULT (DefaultMode)

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

SLEEP_MODE

SG in Sleep-Mode versetzen UDS : $11 ECUReset UDS : $04 EnableRapidPowerShutDown Modus: Default

No arguments.

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

ENERGIESPARMODE

Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default

Arguments

Name Type Comment
MODE int 0x00: Normalmode 0x01: Fertigungsmode 0x02: Transportmode 0x03: Flashmode

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STATUS_ENERGIESPARMODE

Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default

No arguments.

Results

Name Type Comment
STAT_ENERGIESPARMODE_WERT int Ausgabe des Energiesparmodes 0: Kein Energiesparmode gesetzt 1: Produktionsmode gesetzt 2: Transportmode gesetzt 3: Flashmode gesetzt -1: Mode ungueltig
STAT_ENERGIESPARMODE_TEXT string Text zu STAT_ENERGIESPARMODE_WERT
STAT_PRODUKTIONSMODE_EIN int 0: Produktionsmode nicht aktiv 1: Produktionsmode aktiv
STAT_TRANSPORTMODE_EIN int 0: Transportmode nicht aktiv 1: Transportmode aktiv
STAT_FLASHMODE_EIN int 0: Flashmode nicht aktiv 1: Flashmode aktiv
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STATUS_BETRIEBSMODE

Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default

No arguments.

Results

Name Type Comment
STAT_BETRIEBSMODE_WERT int Aktueller Betriebsmode table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle)
STAT_BETRIEBSMODE_TEXT string Textausgabe STAT_BETRIEBSMODE_WERT table Betriebsmode TEXT
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STEUERN_BETRIEBSMODE

Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default

Arguments

Name Type Comment
BETRIEBSMODE int Betriebsmode setzen table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle)

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STEUERGERAETE_RESET

Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default

No arguments.

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STATUS_ROE_REPORT

Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS: $86 ResponseOnEvent $04 report activated events $02 eventWindowTime - infinite (LH Diagnosemaster V11 oder höher, Umsetzung nach LH V6 - V10 wird jedoch toleriert)

No arguments.

Results

Name Type Comment
STAT_ROE_AKTIV char 0x00 = Aktive Fehlermeldung deaktiviert 0x01 = Aktive Fehlermeldung aktiviert 0xFF = Status der aktiven Fehlermeldung nicht feststellbar
STAT_ROE_AKTIV_TEXT string Interpretation von STAT_ROE_AKTIV table UDS_TAB_ROE_AKTIV TEXT
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STEUERN_ROE_PERSISTENT_STOP

Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)

No arguments.

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STEUERN_ROE_PERSISTENT_START

Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)

No arguments.

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

CALID_CVN_LESEN

OBD Calibration ID, CVN Calibration verification number UDS : $22 ReadDataByIdentifier UDS : $2541 CAL-ID Calibration ID and CVN Calibration verification number

No arguments.

Results

Name Type Comment
ANZAHL_CALID_CVN int Anzahl der CAL-ID CVN Paare
CALID string Calibration ID
CVN string Calibration verification number
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

Tables

Index

JOBRESULT

Dimensions: 76 rows × 2 columns

SB STATUS_TEXT
0x10 ERROR_ECU_GENERAL_REJECT
0x11 ERROR_ECU_SERVICE_NOT_SUPPORTED
0x12 ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED
0x13 ERROR_ECU_INCORRECT_MESSAGE_LENGTH_OR_INVALID_FORMAT
0x14 ERROR_ECU_RESPONSE_TOO_LONG
0x21 ERROR_ECU_BUSY_REPEAT_REQUEST
0x22 ERROR_ECU_CONDITIONS_NOT_CORRECT
0x24 ERROR_ECU_REQUEST_SEQUENCE_ERROR
0x25 ERROR_ECU_NO_RESPONSE_FROM_SUBNET_COMPONENT
0x26 ERROR_ECU_FAILURE_PREVENTS_EXECUTION_OF_REQUESTED_ACTION
0x31 ERROR_ECU_REQUEST_OUT_OF_RANGE
0x33 ERROR_ECU_SECURITY_ACCESS_DENIED
0x35 ERROR_ECU_INVALID_KEY
0x36 ERROR_ECU_EXCEED_NUMBER_OF_ATTEMPTS
0x37 ERROR_ECU_REQUIRED_TIME_DELAY_NOT_EXPIRED
0x70 ERROR_ECU_UPLOAD_DOWNLOAD_NOT_ACCEPTED
0x71 ERROR_ECU_TRANSFER_DATA_SUSPENDED
0x72 ERROR_ECU_GENERAL_PROGRAMMING_FAILURE
0x73 ERROR_ECU_WRONG_BLOCK_SEQUENCE_COUNTER
0x78 ERROR_ECU_REQUEST_CORRECTLY_RECEIVED__RESPONSE_PENDING
0x7E ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED_IN_ACTIVE_SESSION
0x7F ERROR_ECU_SERVICE_NOT_SUPPORTED_IN_ACTIVE_SESSION
0x81 ERROR_ECU_RPM_TOO_HIGH
0x82 ERROR_ECU_RPM_TOO_LOW
0x83 ERROR_ECU_ENGINE_IS_RUNNING
0x84 ERROR_ECU_ENGINE_IS_NOT_RUNNING
0x85 ERROR_ECU_ENGINE_RUN_TIME_TOO_LOW
0x86 ERROR_ECU_TEMPERATURE_TOO_HIGH
0x87 ERROR_ECU_TEMPERATURE_TOO_LOW
0x88 ERROR_ECU_VEHICLE_SPEED_TOO_HIGH
0x89 ERROR_ECU_VEHICLE_SPEED_TOO_LOW
0x8A ERROR_ECU_THROTTLE_PEDAL_TOO_HIGH
0x8B ERROR_ECU_THROTTLE_PEDAL_TOO_LOW
0x8C ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_NEUTRAL
0x8D ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_GEAR
0x8F ERROR_ECU_BRAKE_SWITCH_NOT_CLOSED
0x90 ERROR_ECU_SHIFTER_LEVER_NOT_IN_PARK
0x91 ERROR_ECU_TORQUE_CONVERTER_CLUTCH_LOCKED
0x92 ERROR_ECU_VOLTAGE_TOO_HIGH
0x93 ERROR_ECU_VOLTAGE_TOO_LOW
?00? OKAY
?01? ERROR_ECU_NO_RESPONSE
?02? ERROR_ECU_INCORRECT_LEN
?03? ERROR_ECU_INCORRECT_RESPONSE_ID
?04? ERROR_ECU_TA_RESPONSE_NOT_SA_REQUEST
?05? ERROR_ECU_SA_RESPONSE_NOT_TA_REQUEST
?06? ERROR_ECU_RESPONSE_INCORRECT_DATA_IDENTIFIER
?07? ERROR_ECU_RESPONSE_TOO_MUCH_DATA
?08? ERROR_ECU_RESPONSE_TOO_LESS_DATA
?09? ERROR_ECU_RESPONSE_VALUE_OUT_OF_RANGE
?0A? ERROR_TABLE
?10? ERROR_F_CODE
?12? ERROR_INTERPRETATION
?13? ERROR_F_POS
?14? ERROR_ECU_RESPONSE_INCORRECT_IO_CONTROL_PARAMETER
?15? ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_CONTROL_TYPE
?16? ERROR_ECU_RESPONSE_INCORRECT_SUB_FUNCTION
?17? ERROR_ECU_RESPONSE_INCORRECT_DYNAMICALLY_DEFINED_DATA_IDENTIFIER
?18? ERROR_ECU_RESPONSE_NO_STRING_END_CHAR
?19? ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_IDENTIFIER
?1A? ERROR_ECU_RESPONSE_INCORRECT_RESET_TYPE
?1B? ERROR_ECU_RESPONSE_INCORRECT_SERIAL_NUMBER_FORMAT
?1C? ERROR_ECU_RESPONSE_INCORRECT_DTC_BY_STATUS_MASK
?1D? ERROR_ECU_RESPONSE_INCORRECT_DTC_STATUS_AVAILABILITY_MASK
?1E? ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_CONTROL_IDENTIFIER
?50? ERROR_BYTE1
?51? ERROR_BYTE2
?52? ERROR_BYTE3
?60? ERROR_VERIFY
?61? ERROR_ECU_RESPONSE_ZGW
?62? ERROR_ECU_RESPONSE_BACKUP
?70? ERROR_CALID_CVN_INCORRECT_LEN
?80? ERROR_SVK_INCORRECT_LEN
?81? ERROR_SVK_INCORRECT_FINGERPRINT
?F0? ERROR_ARGUMENT
0xXY ERROR_ECU_UNKNOWN_NEGATIVE_RESPONSE

LIEFERANTEN

Dimensions: 149 rows × 2 columns

LIEF_NR LIEF_TEXT
0x000001 Reinshagen / Delphi
0x000002 Leopold Kostal GmbH & Co. KG
0x000003 Hella Fahrzeugkomponenten GmbH
0x000004 Siemens
0x000005 Eaton
0x000006 UTA
0x000007 Helbako GmbH
0x000008 Robert Bosch GmbH
0x000009 Lear Corporation
0x000010 VDO
0x000011 Valeo GmbH
0x000012 MBB
0x000013 Kammerer
0x000014 SWF
0x000015 Blaupunkt
0x000016 Philips
0x000017 Alpine Electronics GmbH
0x000018 Continental Teves AG & Co. OHG
0x000019 Elektromatik Südafrika
0x000020 Harman Becker Automotive Systems
0x000021 Preh GmbH
0x000022 Alps Electric Co. Ltd.
0x000023 Motorola
0x000024 Temic
0x000025 Webasto SE
0x000026 MotoMeter
0x000027 Delphi Automotive PLC
0x000028 DODUCO (Beru)
0x000029 DENSO
0x000030 NEC
0x000031 DASA
0x000032 Pioneer Corporation
0x000033 Jatco
0x000034 FUBA Automotive GmbH & Co. KG
0x000035 UK-NSI
0x000036 AABG
0x000037 Dunlop
0x000038 Sachs
0x000039 ITT
0x000040 FTE (Fahrzeugtechnik Ebern)
0x000041 Megamos
0x000042 TRW Automotive GmbH
0x000043 WABCO Fahrzeugsysteme GmbH
0x000044 ISAD Electronic Systems
0x000045 HEC Hella Electronics Corporation
0x000046 Gemel
0x000047 ZF Friedrichshafen AG
0x000048 GMPT
0x000049 Harman Becker Automotive Systems GmbH
0x000050 Remes GmbH
0x000051 ZF Lenksysteme GmbH
0x000052 Magneti Marelli S.p.A.
0x000053 Johnson Controls Inc.
0x000054 GETRAG Getriebe- und Zahnradf. Hermann Hagenmeyer GmbH & Co. KG
0x000055 Behr-Hella Thermocontrol GmbH
0x000056 Siemens VDO Automotive
0x000057 Visteon Innovation & Technology GmbH
0x000058 Autoliv AB
0x000059 Haberl Electronic GmbH & Co. KG
0x000060 Magna International Inc.
0x000061 Marquardt GmbH
0x000062 AB Elektronik GmbH
0x000063 SDVO/BORG
0x000064 Hirschmann Car Communication GmbH
0x000065 hoerbiger-electronics
0x000066 Thyssen Krupp Automotive
0x000067 Gentex Corporation
0x000068 Atena GmbH
0x000069 Magna-Donelly
0x000070 Koyo Steeting Europe
0x000071 NSI Beheer B.V.
0x000072 Aisin AW Co. Ltd.
0x000073 Schorlock
0x000074 Schrader Electronics Ltd.
0x000075 Huf-Electronics Bretten GmbH
0x000076 CEL
0x000077 AUDIO MOBIL Elektronik GmbH
0x000078 rd electronic
0x000079 iSYS RTS GmbH
0x000080 Westfalia-Automotive GmbH
0x000081 Tyco Electronics
0x000082 Paragon AG
0x000083 IEE S.A.
0x000084 TEMIC AUTOMOTIVE of NA
0x000085 Sonceboz S.A.
0x000086 Meta System S.p.A.
0x000087 Huf Hülsbeck & Fürst GmbH & Co. KG
0x000088 MANN+HUMMEL GmbH
0x000089 Brose Fahrzeugteile GmbH & Co.
0x000090 Keihin
0x000091 Vimercati S.p.a
0x000092 CRH
0x000093 TPO Display Corp
0x000094 Küster Automotive GmbH
0x000095 Hitachi Automotive
0x000096 Continental AG
0x000097 TI-Automotive
0x000098 Hydro
0x000099 Johnson Controls Inc.
0x00009A Takata-Petri
0x00009B Mitsubishi Electric B.V. (Melco)
0x00009C Autokabel
0x00009D GKN Plc
0x00009E Zollner Elektronik AG
0x00009F peiker acustic GmbH & Co. KG
0x0000A0 Bosal-Oris
0x0000A1 Cobasys
0x0000A2 Automotive Lighting Reutlingen GmbH
0x0000A3 CONTI VDO
0x0000A4 A.D.C. Automotive Distance Control Systems GmbH
0x0000A5 Novero Dabendorf GmbH
0x0000A6 LAMES S.p.a.
0x0000A7 Magna/Closures
0x0000A8 Harbin Wan Yu Technology Co
0x0000A9 ThyssenKrupp Presta AG
0x0000AA ArvinMeritor
0x0000AB Kongsberg Automotive GmbH
0x0000AC SMR Automotive Mirrors Stuttgart GmbH
0x0000AD So.Ge.Mi.
0x0000AE MTA S.p.A.
0x0000AF Alfmeier Präzision AG
0x0000B0 Eltek Deutechland GmbH
0x0000B1 OMRON Automotive Electronics Europe GmbH
0x0000B2 ASK Industries GmbH
0x0000B3 CML Innovative Technologies GmbH & Co. KG
0x0000B4 APAG Elektronik AG
0x0000B5 Nexteer Automotive
0x0000B6 Hans Widmaier Fernmelde- und Feinwerktechnik
0x0000B7 Robert Bosch Battery Systems GmbH
0x0000B8 Kyocera Display Europe GmbH
0x0000B9 Magna Powertrain AG & Co. KG
0x0000BA BorgWarner Beru Systems GmbH
0x0000BB BMW AG
0x0000BC Benteler Duncan Plant
0x0000BD U-Shin Deutschland Zugangssysteme GmbH
0x0000BE Schaeffler Technologies AG & Co. KG
0x0000BF JTEKT Corporation
0x0000C0 VLF
0x0000C1 Flextronics
0x0000C2 LG Chem
0x0000C3 Panasonic
0x0000C4 Alpitronic GmbH
0x0000C5 Telemotive AG
0x0000C6 Garmin
0x0000C7 RSG Elotech Elektronische Baugruppen GmbH
0x0000C8 KEBODA TECHNOLOGY CORP
0x0000C9 Aptiv
0x0000CA SEG Automotive Germany GmbH
0xFFFFFF unbekannter Hersteller

FARTTEXTE

Dimensions: 35 rows × 2 columns

ARTNR ARTTEXT
0x00 keine Fehlerart verfügbar
0x04 Fehler momentan nicht vorhanden, aber bereits gespeichert
0x05 Fehler momentan vorhanden und bereits gespeichert
0x08 Fehler momentan nicht vorhanden, aber bereits gespeichert
0x09 Fehler momentan vorhanden und bereits gespeichert
0x0C Fehler momentan nicht vorhanden, aber bereits gespeichert
0x0D Fehler momentan vorhanden und bereits gespeichert
0x20 Fehler momentan nicht vorhanden, aber bereits gespeichert
0x21 Fehler momentan vorhanden und bereits gespeichert
0x24 Fehler momentan nicht vorhanden, aber bereits gespeichert
0x25 Fehler momentan vorhanden und bereits gespeichert
0x28 Fehler momentan nicht vorhanden, aber bereits gespeichert
0x29 Fehler momentan vorhanden und bereits gespeichert
0x2C Fehler momentan nicht vorhanden, aber bereits gespeichert
0x2D Fehler momentan vorhanden und bereits gespeichert
0x40 unbekannte Fehlerart
0x44 Fehler gespeichert
0x45 Fehler gespeichert
0x48 Fehler gespeichert
0x49 Fehler gespeichert
0x4C Fehler gespeichert
0x4D Fehler gespeichert
0x60 Fehler gespeichert
0x61 Fehler gespeichert
0x64 Fehler gespeichert
0x65 Fehler gespeichert
0x68 Fehler gespeichert
0x69 Fehler gespeichert
0x6C Fehler gespeichert
0x6D Fehler gespeichert
0x10 Testbedingungen erfüllt
0x11 Testbedingungen noch nicht erfüllt
0x80 Fehler würde kein Aufleuchten einer Warnlampe verursachen
0x81 Fehler würde das Aufleuchten einer Warnlampe verursachen
0xFF unbekannte Fehlerart

DIGITALARGUMENT

Dimensions: 17 rows × 2 columns

TEXT WERT
ein 1
aus 0
ja 1
nein 0
auf 1
ab 0
an 1
yes 1
no 0
on 1
off 0
up 1
down 0
true 1
false 0
1 1
0 0

PROZESSKLASSEN

Dimensions: 26 rows × 3 columns

WERT PROZESSKLASSE BEZEICHNUNG
0x00 - ungueltig
0x01 HWEL Hardware (Elektronik)
0x02 HWAP Hardwareauspraegung
0x03 HWFR Hardwarefarbe
0x05 CAFD Codierdaten
0x06 BTLD Bootloader
0x08 SWFL Software ECU Speicherimage
0x09 SWFF Flash File Software
0x0A SWPF Pruefsoftware
0x0B ONPS Onboard Programmiersystem
0x0F FAFP FA2FP
0x1A TLRT Temporaere Loeschroutine
0x1B TPRG Temporaere Programmierroutine
0x07 FLSL Flashloader Slave
0x0C IBAD Interaktive Betriebsanleitung Daten
0x10 FCFA Freischaltcode Fahrzeug-Auftrag
0x1C BLUP Bootloader-Update Applikation
0x1D FLUP Flashloader-Update Applikation
0xC0 SWUP Software-Update Package
0xC1 SWIP Index Software-Update Package
0xA0 ENTD Entertainment Daten
0xA1 NAVD Navigation Daten
0xA2 FCFN Freischaltcode Funktion
0x04 GWTB Gateway-Tabelle
0x0D SWFK BEGU: Detaillierung auf SWE-Ebene
0xFF - ungueltig

SVK_ID

Dimensions: 65 rows × 2 columns

WERT BEZEICHNUNG
0x01 SVK_AKTUELL
0x02 SVK_SUPPLIER
0x03 SVK_WERK
0x04 SVK_BACKUP_01
0x05 SVK_BACKUP_02
0x06 SVK_BACKUP_03
0x07 SVK_BACKUP_04
0x08 SVK_BACKUP_05
0x09 SVK_BACKUP_06
0x0A SVK_BACKUP_07
0x0B SVK_BACKUP_08
0x0C SVK_BACKUP_09
0x0D SVK_BACKUP_10
0x0E SVK_BACKUP_11
0x0F SVK_BACKUP_12
0x10 SVK_BACKUP_13
0x11 SVK_BACKUP_14
0x12 SVK_BACKUP_15
0x13 SVK_BACKUP_16
0x14 SVK_BACKUP_17
0x15 SVK_BACKUP_18
0x16 SVK_BACKUP_19
0x17 SVK_BACKUP_20
0x18 SVK_BACKUP_21
0x19 SVK_BACKUP_22
0x1A SVK_BACKUP_23
0x1B SVK_BACKUP_24
0x1C SVK_BACKUP_25
0x1D SVK_BACKUP_26
0x1E SVK_BACKUP_27
0x1F SVK_BACKUP_28
0x20 SVK_BACKUP_29
0x21 SVK_BACKUP_30
0x22 SVK_BACKUP_31
0x23 SVK_BACKUP_32
0x24 SVK_BACKUP_33
0x25 SVK_BACKUP_34
0x26 SVK_BACKUP_35
0x27 SVK_BACKUP_36
0x28 SVK_BACKUP_37
0x29 SVK_BACKUP_38
0x2A SVK_BACKUP_39
0x2B SVK_BACKUP_40
0x2C SVK_BACKUP_41
0x2D SVK_BACKUP_42
0x2E SVK_BACKUP_43
0x2F SVK_BACKUP_44
0x30 SVK_BACKUP_45
0x31 SVK_BACKUP_46
0x32 SVK_BACKUP_47
0x33 SVK_BACKUP_48
0x34 SVK_BACKUP_49
0x35 SVK_BACKUP_50
0x36 SVK_BACKUP_51
0x37 SVK_BACKUP_52
0x38 SVK_BACKUP_53
0x39 SVK_BACKUP_54
0x3A SVK_BACKUP_55
0x3B SVK_BACKUP_56
0x3C SVK_BACKUP_57
0x3D SVK_BACKUP_58
0x3E SVK_BACKUP_59
0x3F SVK_BACKUP_60
0x40 SVK_BACKUP_61
0xXY ERROR_UNKNOWN

DTCEXTENDEDDATARECORDNUMBER

Dimensions: 5 rows × 3 columns

WERT TEXT ANZ_BYTE
0x00 ISO_RESERVED 0
0x01 CONDITION_BYTE 1
0x02 HFK 1
0x03 HLZ 1
0xFF RECORD_UNKNOWN 0

DTCSNAPSHOTIDENTIFIER

Dimensions: 9 rows × 9 columns

UWNR UWTEXT UW_EINH L/H UWTYP NAME MUL DIV ADD
0x1700 KM_STAND 0-n - 0xFFFFFF - 1 1 0.000000
0x1701 ABS_ZEIT 0-n - 0xFFFFFFFF - 1 1 0.000000
0x1702 SAE_CODE 0-n - 0xFFFFFF - 1 1 0.000000
0x1731 Fehlerklasse_DTC - - u char - 1 1 0.000000
0x1750 PWF_Basinetz 0-n - 0xFF - 1 1 0.000000
0x1751 PWF_Teilnetz 0-n - 0xFFFFFF - 1 1 0.000000
0x1768 KM_STAND_SUP 0-n - 0xFFFFFFFF - 1 1 0.000000
0x1769 ABS_ZEIT_SUP 0-n - 0xFFFFFFFF - 1 1 0.000000
0xFFFF IDENTIFIER_UNKNOWN - - 0xFFFFFF - 1 1 0.000000

TAB_ZEIT_SYNCMETHOD

Dimensions: 4 rows × 2 columns

WERT TEXT
0x00 Combi-Time
0x01 DMCS
0x02 IEEE802.1AS
0x03 invalid

TAB_ZEIT_USER_INFO

Dimensions: 8 rows × 2 columns

WERT TEXT
0x00 out of sync, no time available
0x01 insync, ms ECU overall, not comparable
0x02 ms ECU overall, not comparable
0x03 ms ECU overall, comparable
0x04 ms ECU overall, not comparable
0x05 ms ECU overall, comparable
0x06 invalid
0x07 invalid

FEHLERKLASSE

Dimensions: 5 rows × 2 columns

NR TEXT
0x00 Keine Fehlerklasse verfuegbar
0x01 Ueberpruefung bei naechstem Werkstattbesuch
0x02 Ueberpruefung bei naechstem Halt
0x04 Ueberpruefung sofort erforderlich !
0xFF unbekannte Fehlerklasse

DIAGMODE

Dimensions: 14 rows × 3 columns

NR MODE MODE_TEXT
0x00 UNGUELTIG DefaultMode
0x01 DEFAULT DefaultMode
0x02 ECUPM ECUProgrammingMode
0x03 ECUEXTDIAG ECUExtendedDiagnosticSession
0x04 ECUSSDS ECUSafetySystemDiagnosticSession
0x40 ECUEOL ECUEndOfLineSession
0x41 ECUCODE ECUCodingSession
0x42 ECUSWT ECUSwtSession
0x43 ECUHDD ECUHDDDownloadSession
0x44 ECURSU ECURsuSession
0x4F ECUDEVELOP ECUDevelopmentSession
0x5F ECUGDM ECUGarageDiagnoseMode
0x61 ECUSUPSPEC ECUSupplierSpecificSession
0xXY -- unbekannter Diagnose-Mode

IARTTEXTE

Dimensions: 35 rows × 2 columns

ARTNR ARTTEXT
0x00 keine Fehlerart verfügbar
0x04 Fehler momentan nicht vorhanden, aber bereits gespeichert
0x05 Fehler momentan vorhanden und bereits gespeichert
0x08 Fehler momentan nicht vorhanden, aber bereits gespeichert
0x09 Fehler momentan vorhanden und bereits gespeichert
0x0C Fehler momentan nicht vorhanden, aber bereits gespeichert
0x0D Fehler momentan vorhanden und bereits gespeichert
0x20 Fehler momentan nicht vorhanden, aber bereits gespeichert
0x21 Fehler momentan vorhanden und bereits gespeichert
0x24 Fehler momentan nicht vorhanden, aber bereits gespeichert
0x25 Fehler momentan vorhanden und bereits gespeichert
0x28 Fehler momentan nicht vorhanden, aber bereits gespeichert
0x29 Fehler momentan vorhanden und bereits gespeichert
0x2C Fehler momentan nicht vorhanden, aber bereits gespeichert
0x2D Fehler momentan vorhanden und bereits gespeichert
0x40 unbekannte Fehlerart
0x44 Fehler gespeichert
0x45 Fehler gespeichert
0x48 Fehler gespeichert
0x49 Fehler gespeichert
0x4C Fehler gespeichert
0x4D Fehler gespeichert
0x60 Fehler gespeichert
0x61 Fehler gespeichert
0x64 Fehler gespeichert
0x65 Fehler gespeichert
0x68 Fehler gespeichert
0x69 Fehler gespeichert
0x6C Fehler gespeichert
0x6D Fehler gespeichert
0x10 Testbedingungen erfüllt
0x11 Testbedingungen noch nicht erfüllt
0x80 Fehler würde kein Aufleuchten einer Warnlampe verursachen
0x81 Fehler würde das Aufleuchten einer Warnlampe verursachen
0xFF unbekannte Fehlerart

UDS_TAB_ROE_AKTIV

Dimensions: 3 rows × 2 columns

NR TEXT
0x00 Aktive Fehlermeldung deaktiviert
0x01 Aktive Fehlermeldung aktiviert
0xFF Status der aktiven Fehlermeldung nicht feststellbar

ANFORDERUNG_MIL_DIAGNOSE_OBD_SCR

Dimensions: 3 rows × 2 columns

WERT TEXT
0x0000 Anforderung MIL aus
0x0001 Anforderung MIL ein
0xFFFF Wert ungültig

ARG_0XAE64_R

Dimensions: 2 rows × 14 columns

ARG STR STPR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
DOSIERMASSE + - mg high unsigned int - - 1.0 8.0 0.0 0.0 524280.0 Dosiermasse in mg
MASSENSTROM + - mg/s high unsigned int - - 1.0 0.015625 0.0 0.0 1023.98437 Massenstrom in mg/s

ARG_0XAE68_R

Dimensions: 1 rows × 14 columns

ARG STR STPR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
BITMASKE_PARAMETER + - 0-n high unsigned int - AR_TESTAUSWAHL - - - - - Übergabeparameter für Inbetriebnahme Routine.

ARG_0XAE6B_R

Dimensions: 1 rows × 14 columns

ARG STR STPR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
UMPUMPMENGE + - l high unsigned int - - 1024.0 1.0 0.0 0.0 63.999 tbd

ARG_0XD280_D

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
STEUERN_FOERDERPUMPE % high signed int - - 163.84 1.0 0.0 0.0 33.0 Test der Förderpumpe

ARG_0XD281_D

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
STEUERN_RUECKFOERDERPUMPE % high signed int - - 163.84 1.0 0.0 0.0 33.0 tbd

ARG_0XD282_D

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
STEUERN_AKTIVTANKHEIZUNG % high signed int - - 163.84 1.0 0.0 0.0 100.0 Test zum Steuern der Aktivtankheizung

ARG_0XD283_D

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
STEUERN_DOSIERLEITUNGSHEIZUNG % high signed int - - 163.84 1.0 0.0 0.0 100.0 Test zum Steuern der Dosierleitungsheizung

ARG_0XD284_D

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
STEUERN_DOSIERVENTIL % high signed int - - 163.84 1.0 0.0 0.0 80.0 Test zum Steuern des Dosierventils

ARG_0XD285_D

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
STEUERN_TRANSFERPUMPE % high signed int - - 163.84 1.0 0.0 0.0 100.0 Test zum Steuern der Transferpumpe.

ARG_0XD286_D

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
LANGZEITERFASSUNG_DOSIERMENGE g high unsigned long - - 1000.0 1.0 0.0 0.0 2147483.64 Langzeiterfassung der Dosiermenge.

ARG_0XD287_D

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
LANGZEITERFASSUNG_UMPUMPMENGE l high unsigned int - - 10.0 1.0 0.0 0.0 6553.5 Langzeiterfassung der Umpumpmenge

ARG_0XD290_D

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
STEUERN_ERSTBEFUELLUNGSSTATUS 0/1 high unsigned char - - - - - - - Manuelles Setzen des Erstbefüllungsstatus. Neues TFM - Setzen auf 0. Neues SG - Setzen auf1.

ARG_0XD291_D

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
STEUERN_ZEITDAUER_SPULENHEIZEN 0/1 high unsigned char - - - - - - - Manuelles Rücksetzen der Zeitdauer für das Heizen der Spule des Dosierventils auf 0.

ARG_0XD292_D

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
STEUERN_ZEITDAUER_UEBERTEMPERATUR_DOSIERVENTIL 0/1 high unsigned char - - - - - - - Manuelles Rücksetzen der Zeitdauer für die Übertemperatur des Dosierventils

ARG_0XD293_D

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
STEUERN_INITIALISIERUNG_LERNWERT_FOERDERPUMPE 0/1 high unsigned char - - - - - - - Manuelles Neuinitialisieren des Lernwerts der Förderpumpe.

ARG_0XD294_D

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
STEUERN_INITIALISIERUNG_LERNWERT_DOSIERVENTIL 0/1 high unsigned char - - - - - - - Manuelles Neuinitialisieren des Lernwerts der Förderpumpe.

ARG_0XD29A_D

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
STEUERN_INITIALISIERUNG_FUELLMENGE_AKTIVTANK 0/1 high unsigned char - - - - - - - Manuelles Neuinitialisieren der Füllmenge des Aktivtanks.

ARG_0XD29B_D

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
STEUERN_INITIALISIERUNG_FUELLMENGE_PASSIVTANK 0/1 high unsigned char - - - - - - - Manuelles Neuinitialisieren der Füllmenge des Passivtanks.

ARG_0XD29C_D

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
STEUERN_INITIALISIERUNG_RAM 0/1 high unsigned char - - - - - - - Manuelles Neuinitialisieren zahlreicher nicht OBD-relevanter Systemgrößen.

AR_TESTAUSWAHL

Dimensions: 15 rows × 2 columns

WERT TEXT
0x0001 Test Druckaufbau
0x0004 Test Leckage
0x0010 Test Teilrücksaugen
0x0020 Test Komplettrücksaugen
0x0040 Test Trockentaktung
0x0080 Test Umpumpe
0x0100 Test Aktivtankheizung
0x0200 Test Dosierleitungsheizung
0x0400 Test Dosiermenge
0x0011 Tests Druckaufbau, Teilrücksaugen
0x0015 Tests Druckaufbau, Leckage, Teilrücksaugen
0x0315 Test Heizung, Druckaufbau, Leckage, Teilrücksaugen
0x0345 Tests Trockentaktung, Heizung, Druckaufbau, Leckage
0x0355 Tests Trockentaktung, Heizung, Druckaufbau, Leckage, Teilrücksaugen
0x0755 Systemgutprüfung

BF_ACT_INIT_TESTS

Dimensions: 9 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ACT_DRUCKAUFBAU 0/1 high unsigned int 0x0001 - - - - Wenn 1: Teilschritt Druckaufbau läuft gerade.
STAT_ACT_LECKAGE 0/1 high unsigned int 0x0004 - - - - Wenn 1: Teilschritt Leckage läuft gerade.
STAT_ACT_TEILRUECKSAUGEN 0/1 high unsigned int 0x0010 - - - - Wenn 1: Teilschritt Teilrücksaugen läuft gerade.
STAT_ACT_KOMPLETTRUECKSAUGEN 0/1 high unsigned int 0x0020 - - - - Wenn 1: Teilschritt Komplettrücksaugen läuft gerade.
STAT_ACT_TROCKENTAKTUNG 0/1 high unsigned int 0x0040 - - - - Wenn 1: Teilschritt Trockentaktung Dosierventil läuft gerade.
STAT_ACT_TRANSFERPUMPE 0/1 high unsigned int 0x0080 - - - - Wenn 1: Teilschritt Test der Transferpumpe läuft gerade.
STAT_ACT_AKTIVTANKHEIZUNG 0/1 high unsigned int 0x0100 - - - - Wenn 1: Teilschritt Test der Aktivtankheizung läuft gerade.
STAT_ACT_DOSIERLEITUNGSHEIZUNG 0/1 high unsigned int 0x0200 - - - - Wenn 1: Teilschritt Test der Dosierleitungsheizung läuft gerade.
STAT_ACT_DOSIERMENGE 0/1 high unsigned int 0x0400 - - - - Wenn 1: Teilschritt Dosiermengentest läuft gerade.

BF_DWIS_ANFORDERUNG_GRUPPE

Dimensions: 8 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_GRUPPE_0 0/1 high unsigned int 0x0001 - - - - DWIS-Request Gruppe 0 aktiv
STAT_GRUPPE_1 0/1 high unsigned int 0x0002 - - - - DWIS-Request Gruppe 1 aktiv
STAT_GRUPPE_2 0/1 high unsigned int 0x0004 - - - - DWIS-Request Gruppe 2 aktiv
STAT_GRUPPE_3 0/1 high unsigned int 0x0008 - - - - DWIS-Request Gruppe 3 aktiv
STAT_GRUPPE_4 0/1 high unsigned int 0x0010 - - - - DWIS-Request Gruppe 4 aktiv
STAT_GRUPPE_5 0/1 high unsigned int 0x0020 - - - - DWIS-Request Gruppe 5 aktiv
STAT_GRUPPE_6 0/1 high unsigned int 0x0040 - - - - DWIS-Request Gruppe 6 aktiv
STAT_GRUPPE_7 0/1 high unsigned int 0x0080 - - - - DWIS-Request Gruppe 7 aktiv

BF_DWIS_ANFORDERUNG_TAMPERING

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_VERY_FAST 0/1 high unsigned int 0x0001 - - - - sehr schnell
STAT_FAST 0/1 high unsigned int 0x0002 - - - - schnell
STAT_MEDIUM 0/1 high unsigned int 0x0004 - - - - mittel
STAT_SLOW 0/1 high unsigned int 0x0008 - - - - langsam
STAT_VERY_SLOW 0/1 high unsigned int 0x0010 - - - - sehr langsam

BF_FOERDERPUMPE_FEHLER_HIGH_BYTE

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ROTOR_STALL_DIAGNOSIS 0/1 high unsigned int 0x0001 - - - - Diagnose Blockierender Rotor
STAT_SW_OVER_CURRENT_DIAGNOSIS 0/1 high unsigned int 0x0002 - - - - Diagnose SW Überstrom
STAT_OPEN_LOAD_HALL_SENSOR_DIAGNOSIS 0/1 high unsigned int 0x0004 - - - - Diagnose Leitungsunterbechung Hall Sensoren
STAT_SPEED_CONTROLLER_SETPOINT_DIAGNOSIS 0/1 high unsigned int 0x0008 - - - - Diagnose Sollwert Geschwindigkeitsregler
STAT_ELECTRIC_MOTOR_LOW_CURRENT_CONSUMPTION 0/1 high unsigned int 0x0010 - - - - Elektrischer Motor: niedriger Stromverbrauch
STAT_INTERMITTENT_OPEN_LOAD_DIAGNOSIS 0/1 high unsigned int 0x0020 - - - - Diagnose Wackelkontakt

BF_FOERDERPUMPE_FEHLER_LOW_BYTE

Dimensions: 16 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_OVER_TEMPERATURE_FLAG 0/1 high unsigned int 0x0001 - - - - Übertemperatur
STAT_OPEN_LOAD_FOR_BRIDGE_OPERATION 0/1 high unsigned int 0x0002 - - - - Leitungsunterbrechung im Brückenbetrieb
STAT_SHORT_TO_GROUND_HALF_BRIDGE_1 0/1 high unsigned int 0x0004 - - - - Halbbrücke 1: Kurzschluss nach Masse
STAT_SHORT_TO_BATTERY_HALF_BRIDGE_1 0/1 high unsigned int 0x0008 - - - - Halbbrücke 1: Kurzschluss nach Batterie
STAT_SHORT_TO_GROUND_HALF_BRIDGE_2 0/1 high unsigned int 0x0010 - - - - Halbbrücke 2: Kurzschluss nach Masse
STAT_SHORT_TO_BATTERY_HALF_BRIDGE_2 0/1 high unsigned int 0x0020 - - - - Halbbrücke 2: Kurzschluss nach Batterie
STAT_SHORT_TO_GROUND_HALF_BRIDGE_3 0/1 high unsigned int 0x0040 - - - - Halbbrücke 3: Kurzschluss nach Masse
STAT_SHORT_TO_BATTERY_HALF_BRIDGE_3 0/1 high unsigned int 0x0080 - - - - Halbbrücke 3: Kurzschluss nach Batterie
STAT_OPEN_LOAD_FLAG_FOR_3RD_HALF_BRIDGE 0/1 high unsigned int 0x0100 - - - - Dritte Halbbrücke: Leitungsunterbrechung
STAT_SHORT_TO_GROUND_3RD_HALF_BRIDGE 0/1 high unsigned int 0x0200 - - - - Dritte Halbbrücke: Kurzschluss nach Masse
STAT_SHORT_TO_BATTEY_3RD_HALF_BRIDGE 0/1 high unsigned int 0x0400 - - - - Dritte Halbbrücke: Kurzschluss nach Batterie
STAT_OPEN_LOAD_FLAG_3RD_HALF_BRIDGE 0/1 high unsigned int 0x0800 - - - - Dritte Halbbrücke: Leitungsunterbrechung
STAT_UNDER_VOLTAGE_FLAG 0/1 high unsigned int 0x1000 - - - - Unterspannung
STAT_OVER_VOLTAGE_FLAG 0/1 high unsigned int 0x2000 - - - - Überspannung
STAT_WRONG_COMMAND_OF_BRUSHLESS_MOTOR 0/1 high unsigned int 0x4000 - - - - falscher Befehl des bürstenlosen Motors: - alle HALLx Eingänge bleiben auf 0 oder auf 1 hängen - der Kommutationsschritt (HALLx Kombination) ist nicht mit vorhergehendem Schritt konsistent
STAT_CURRENT_LIMITATION_FLAG 0/1 high unsigned int 0x8000 - - - - Strombegrenzung

BF_FREIGABEMASKE_FUER_FUELLSTANDSFUNKTION_AKTIVTANK

Dimensions: 16 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_AUSGEWAEHLTE_RELEVANTE_BEDINGUNGEN 0/1 high unsigned int 0x0001 - - - - Aus dem logischen Bereich vom statischen Fall ausgewaehlte relevante Bedingungen fuer direkten Stand als dynamische Bedingungen
STAT_FAHRZEUG_IN_BEWEGUNG 0/1 high unsigned int 0x0002 - - - - Fahrzeug in Bewegung
STAT_LONGITUDINALE_UND_TRANSVERSALE_BESCHLEUNIGUNG 0/1 high unsigned int 0x0004 - - - - Gueltige longitudinale/transversale Beschleunigung
STAT_BEENDIGUNG_DER_SENSORAKTIVIERUNG 0/1 high unsigned int 0x0008 - - - - Initiale Verzoegerung bei Start für Beendingung der Sensoraktivierung
STAT_FREIGABE_DIREKTE_STANDFUNKTION 0/1 high unsigned int 0x0010 - - - - Freigabe der direkten Standfunktion
STAT_DIREKTE_STANDMESSUNG 0/1 high unsigned int 0x0020 - - - - Direkte Standmessung gueltig
STAT_DIREKTE_STANDMESSUNG_MIT_ABSCHALTVERZOEGERUNG 0/1 high unsigned int 0x0040 - - - - Direkte Standmessung gueltig (mit Abschaltverzoegerung)
STAT_TANKTEMPERATUR_UND_AUSSENTEMPERATUR 0/1 high unsigned int 0x0080 - - - - Tanktemperatur und Aussentemperature für direkten Stand ok
STAT_DIREKTE_STANDMESSUNG_STATISCH 0/1 high unsigned int 0x0100 - - - - Direkte Standmessung gueltig (Statische Bedingungen)
STAT_DIREKTER_STAND_HOHE_AENDERUNGSPRUEFUNG 0/1 high unsigned int 0x0200 - - - - Direkter Stand: hohe Aendungspruefung ok
STAT_COMBI_STAND_FUNKTION 0/1 high unsigned int 0x0400 - - - - Freigabe Combi-Stand-Funktion
STAT_COMBI_STANDMESSUNG 0/1 high unsigned int 0x0800 - - - - Combi-Standmessung gueltig
STAT_COMBI_STANDMESSUNG_MIT_ABSCHALTVERZOEGERUNG 0/1 high unsigned int 0x1000 - - - - Combi-Standmessung gueltig (mit Abschaltverzoegerung)
STAT_TANKTEMP_UND_AUSSENTEMP_FUER_COMBI_TEMP 0/1 high unsigned int 0x2000 - - - - Tanktemperatur und Aussentemperatur für Combi-Temperature ok
STAT_COMBI_STANDMESSUNG_STATISCHE_BEDINGUNG 0/1 high unsigned int 0x4000 - - - - Combi-Stand-Messung gueltig (Statische Bedingungen)
STAT_COMBI_STAND_HOHE_AENDERUNGSPRUEFUNG 0/1 high unsigned int 0x8000 - - - - Combi Stand: hohe Aenderungspruefung ok

BF_FREIGABEMASKE_FUER_FUELLSTANDSFUNKTION_PASSIVTANK

Dimensions: 7 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_TEMPERATURBEDINGUNG 0/1 high unsigned int 0x01 - - - - Temperaturbedingung; Passivtank nicht gefroren
STAT_FREIGABE_FEHLERMANAGEMENT 0/1 high unsigned int 0x02 - - - - Freigabe Fehlermanagement
STAT_FUELLSTANDSMESSUNG 0/1 high unsigned int 0x04 - - - - Keine gültige Füllstandmessung
STAT_FUELLSTANDSUEBERWACHUNG 0/1 high unsigned int 0x08 - - - - Längere Zeit keine gültige Füllstandsmessung
STAT_FAHRZEUG_IN_BEWEGUNG 0/1 high unsigned int 0x10 - - - - Fahrzeug fährt
STAT_BESCHLEUNIGUNGSSIGNALE 0/1 high unsigned int 0x20 - - - - Beschleunigungssignale sind gültig
STAT_INITIALSIERUNG_CAN 0/1 high unsigned int 0x40 - - - - Initialisierung CAN abgeschlossen

BF_FREIGABE_ROUTINE

Dimensions: 7 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_BATTERIESPANNUNG_OK 0/1 high unsigned char 0x01 - - - - Wenn 1: Batteriespannung ok.
STAT_MOTORDREHZAHL_OK 0/1 high unsigned char 0x02 - - - - Wenn 1: Drehzahl Verbrennungsmotor ok.
STAT_FAHRZEUGGESCHWINDIGKEIT_OK 0/1 high unsigned char 0x04 - - - - Wenn 1: Fahrzeuggeschwindigkeit ok.
STAT_AUSSENTEMPERATUR_OK 0/1 high unsigned char 0x08 - - - - Wenn 1: Außentemperatur ok.
STAT_AKTIVTANKTEMPERATUR_OK 0/1 high unsigned char 0x10 - - - - Wenn 1: AdBlue-Temperatur im Aktivtank ok.
STAT_ABGASTEMPERATUR_OK 0/1 high unsigned char 0x20 - - - - Wenn 1: Abgastemperatur ok.
STAT_QUERVERRIEGELUNG_OK 0/1 high unsigned char 0x40 - - - - Wenn 1: Querverriegelungen in der Software ok.

BF_LEVELSENSOR_AKTIVTANK_FEHLER

Dimensions: 10 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ASIC_ERROR_PDU 0/1 high unsigned int 0x0001 - - - - ASIC PDU (0=kein Fehler, 1=ASIC PDU Fehler)
STAT_ASIC_ERROR_MEMORY 0/1 high unsigned int 0x0002 - - - - ASC MEMORY (0=kein Fehler, 1=ASIC MEMORY Fehler)
STAT_NTC_ERROR 0-n high unsigned int 0x000C NTC_ERROR - - - NTC Fehler (0=kein Fehler, 4=offene Leitung, 8=Kurzschluss)
STAT_PIEZO_TD1_ERROR 0/1 high unsigned int 0x0010 - - - - Piezo TD1 Fehler (0=kein Fehler, 1=offene Leitung oder Kurzschluss)
STAT_PIEZO_TD2_ERROR 0/1 high unsigned int 0x0020 - - - - Piezo TD2 Fehler (0=kein Fehler, 1=offene Leitung oder Kurzschluss)
STAT_2ND_PIEZO_VALIDITY 0/1 high unsigned int 0x0080 - - - - Zweite Piezo Gültigkeitsdauer (0=nicht gültig, 1=Stufe TD2 verfügbar)
STAT_TEMPERATURE_IN_RANGE_FLAG 0-n high unsigned int 0x0300 TEMPERATURBEREICH - - - Temperatur
STAT_POWER_SUPPLY_STATUS 0-n high unsigned int 0x0C00 STATUS_VERSORGUNGSSPANNUNG - - - Status Versorgungsspannung
STAT_MEASUREMENT_STATUS 0-n high unsigned int 0x7000 MESSAUFZEICHNUNG - - - Status Messaufzeichnung
STAT_MEASUREMENT_UPDATE 0/1 high unsigned int 0x8000 - - - - Anzeige zur Aktualisierung der Messung (0: Messung läuft, 1: Messwerte werden aktualisiert)

BF_LEVELSENSOR_PASSIVTANK_FEHLER

Dimensions: 1 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_MESSUNGEN 0-n high unsigned int 0x07 MESSUNGEN - - - Der STATE kann als höchsten Wert 5 annehmen (5 gültige Messungen).

BF_SCR_INIT

Dimensions: 9 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_DRUCKAUFBAU 0/1 high unsigned int 0x0001 - - - - Wenn 1: Druckaufbau erfolgreich beendet.
STAT_LECKAGE 0/1 high unsigned int 0x0004 - - - - Wenn 1: Leckagetest erfolgreich beendet.
STAT_TEILRUECKSAUGEN 0/1 high unsigned int 0x0010 - - - - Wenn 1: Teilrücksaugen erfolgreich beendet.
STAT_KOMPLETTRUECKSAUGEN 0/1 high unsigned int 0x0020 - - - - Wenn 1: Komplettrücksaugen erfolgreich beendet.
STAT_TROCKENTAKTUNG 0/1 high unsigned int 0x0040 - - - - Wenn 1: Trockentaktung Dosierventil erfolgreich beendet.
STAT_TRANSFERPUMPE 0/1 high unsigned int 0x0080 - - - - Wenn 1: Test der Transferpumpe erfolgreich beendet.
STAT_AKTIVTANKHEIZUNG 0/1 high unsigned int 0x0100 - - - - Wenn 1: Test der Aktivtankheizung erfolgreich beendet.
STAT_DOSIERLEITUNGSHEIZUNG 0/1 high unsigned int 0x0200 - - - - Wenn 1: Test der Dosierleitungsheizung erfolgreich beendet.
STAT_DOSIERMENGE 0/1 high unsigned int 0x0400 - - - - Wenn 1: Dosiermengentest erfolgreich beendet.

BF_STATUS_ANTRIEB_FAHRZEUG

Dimensions: 3 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_VERBRENNUNGSMOTOR 0-n high unsigned char 0x1F VERBRENNUNGSMOTOR - - - Status des Verbrennungsmotors
STAT_E_MASCHINE 0/1 high unsigned char 0x80 - - - - E-Maschine ist nach Anforderung Fahrbereitschaft von CAS/FEM elektrisch fahrbereit oder bereits aktiv: 0x0--- ---- Keine E-Maschine vorhanden: 0x1--- ----
STAT_INIT 0/1 high unsigned char 0x83 - - - - Initialisierung: 1000 0011

BF_STATUS_BEREITSTELLUNG_SCR_ADDITIV

Dimensions: 1 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SCR_DOSIERFREIGABE 0/1 high unsigned int 0x01 - - - - SCR-Dosierfreigabe

BF_STATUS_OBD_ZYKLUS

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_WARM_UP_CYCLE 0/1 high unsigned char 0x01 - - - - Warm-Up-Zyklus nicht aktiv/aktiv (0/1)
STAT_DRIVING_CYLCE 0/1 high unsigned char 0x02 - - - - Driving-Zyklus nicht aktiv/aktiv (0/1)
STAT_PFC_CYCLE 0/1 high unsigned char 0x10 - - - - Kein PFC-Zyklus/PFC-Zyklus erfuellt (0/1)
STAT_RBM_CYCLE 0-n high unsigned char 0x24 RBM_CYCLE - - - RBM-Zyklus nicht aktiv/aktiv/nicht erfuellbar
STAT_SIGNAL_UNGUELTIG 0/1 high unsigned char 0x3F - - - - Signal ungültig

BF_STATUS_SPERRE_SCR_SYSTEM

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_VERRIEGELUNGSINFORMATION_0 0/1 high unsigned int 0x01 - - - - Verriegelungsinformation 0
STAT_VERRIEGELUNGSINFORMATION_1 0/1 high unsigned int 0x02 - - - - Verriegelungsinformation 1
STAT_VERRIEGELUNGSINFORMATION_2 0/1 high unsigned int 0x04 - - - - Verriegelungsinformation 2
STAT_VERRIEGELUNGSINFORMATION_3 0/1 high unsigned int 0x08 - - - - Verriegelungsinformation 3
STAT_VERRIEGELUNGSINFORMATION_4 0/1 high unsigned int 0x10 - - - - Verriegelungsinformation 4

BF_STATUS_SYSTEM_FEHLER_OBD_SCR

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_OBD_FEHLER_1 0/1 high unsigned int 0x01 - - - - OBD Fehler 1
STAT_OBD_FEHLER_2 0/1 high unsigned int 0x02 - - - - OBD Fehler 2
STAT_OBD_FEHLER_3 0/1 high unsigned int 0x04 - - - - OBD Fehler 3
STAT_OBD_FEHLER_4 0/1 high unsigned int 0x08 - - - - OBD Fehler 4
STAT_OBD_FEHLER_5 0/1 high unsigned int 0x10 - - - - OBD Fehler 5

BETRIEBSMODE

Dimensions: 6 rows × 3 columns

WERT TEXT BEDEUTUNG
0x00 Allgemeiner Fertigungs- und Energiesparmode Hier deaktivierte Funktionen gemäß FeTra-Liste festhalten
0x01 Spezieller Energiesparmode -
0x02 ECOS-Mode -
0x03 MOST-Mode -
0x04 Rollenmode -
0xFF ungültiger Betriebsmode ungültig

FDETAILSTRUKTUR

Dimensions: 6 rows × 2 columns

NAME TYP
F_UWB_ERW ja
SAE_CODE ja
F_HLZ ja
F_SEVERITY nein
F_UWB_SATZ 2
F_HLZ_VIEW ja

FORTTEXTE

Dimensions: 206 rows × 4 columns

ORT ORTTEXT EREIGNIS_DTC FEHLERKLASSE
0x020B00 Energiesparmode aktiv 0 -
0x02FF0B Dummy-Fehlerspeichereintrag im Komponentenfehlerbereich nur für Testzwecke 1 -
0x805270 Aktivtank, Förderpumpe, Hall-Sensor, Signalfehler. 0 -
0x805271 Aktivtank, Förderpumpe, Kurzschluss nach Masse. 0 -
0x805272 Aktivtank, Förderpumpe, Kurzschluss nach Plus. 0 -
0x805273 Aktivtank, Förderpumpe, Leitungsunterbrechung. 0 -
0x805275 Aktivtank, Förderpumpe klemmt. 0 -
0x805276 Aktivtank, Datencheckfehler SENT_1 (Level, Temperatur_1, Qualität). 0 -
0x805277 Aktivtank, Datencheckfehler SENT_2 (Druck, Temperatur_2). 0 -
0x805278 Aktivtank, Initialisierungsfehler SENT_1 (Level, Temperatur_1, Qualität). 0 -
0x805279 Aktivtank, Initialisierungsfehler SENT_2 (Druck, Temperatur_2). 0 -
0x80527A Aktivtank, Kommunikationsfehler SENT_1 (Level, Temperatur_1, Qualität). 0 -
0x80527B Aktivtank, Kommunikationsfehler SENT_2 (Druck, Temperatur_2). 0 -
0x80527C Aktivtank, Signalfehler SENT_1 (Level, Temperatur_1, Qualität). 0 -
0x80527D Aktivtank, Signalfehler SENT_2 (Druck, Temperatur_2). 0 -
0x80527E Aktivtank, Datenfehler Multiplexing SENT_1 (Level, Temperatur_1, Qualität). 0 -
0x805280 Heizung, mehrfacher Fehler. 0 -
0x805281 Aktivtankheizung, Leistung zu gering. 0 -
0x805282 Aktivtankheizung, Leistung zu hoch. 0 -
0x805283 Aktivtankheizung, Leitungsunterbrechung. 0 -
0x805284 Aktivtankheizung, Low Side, Kurschluss nach Masse. 0 -
0x805285 Aktivtankheizung, Low Side, Kurzschluss nach Plus. 0 -
0x805286 Aktivtankheizung, Signal Range Check high. 0 -
0x805287 Aktivtankheizung, Fehler bei aktiver Heizanforderung. 0 -
0x805288 Aktivtank leer. 0 -
0x805289 Dosierleitungsheizung, Leistung zu gering. 0 -
0x80528A Dosierleitungsheizung, Leistung zu hoch. 0 -
0x80528B Dosierleitungsheizung, Leitungsunterbrechung. 0 -
0x80528C Dosierleitungsheizung, Low Side, Kurschluss nach Masse. 0 -
0x80528D Dosierleitungsheizung, Low Side, Kurzschluss nach Plus. 0 -
0x80528E Dosierleitungsheizung, Signal Range Check high. 0 -
0x80528F Dosierleitungsheizung, Fehler bei aktiver Heizanforderung. 0 -
0x805290 Dosiermengenabweichung, dosierte Menge gemäß Fördervolumen zu gering. 0 -
0x805291 Dosiermengenabweichung, dosierte Menge gemäß Fördervolumen zu hoch. 0 -
0x805292 Dosierventil, High Side, Kurzschluss nach Masse. 0 -
0x805293 Dosierventil, High Side, Kurzschluss nach Plus. 0 -
0x805294 Dosierventil, Leitungsunterbrechung. 0 -
0x805295 Dosierventil, Low Side, Kurzschluss nach Masse. 0 -
0x805296 Dosierventil, Low Side, Kurzschluss nach Plus. 0 -
0x805297 Dosierventil, Spulenstrom zu hoch. 0 -
0x805298 Dosierventil, Spulenstrom zu niedrig. 0 -
0x80529A Dosierventil, unzureichende Kühlung. 0 -
0x80529B Heizung, High Side, Kurzschluss nach Masse. 0 -
0x80529C Heizung, High Side, Kurzschluss nach Plus. 0 -
0x80529D Aktivtankheizung, Kurzschluss nach Last. 0 -
0x80529F Dosierleitungsheizung, Kurzschluss nach Last. 0 -
0x8052A0 Passivtank, Levelsensor, Echofehler. 0 -
0x8052A1 Passivtank, Levelsensor, Offset zu Referenztemperatur zu groß (positiv). 0 -
0x8052A2 Passivtank, Levelsensor, Offset zu Referenztemperatur zu groß (negativ). 0 -
0x8052A3 Passivtank, Levelsensor, Sensorfehler. 0 -
0x8052A4 Passivtank, Sensorsignal PWM (Level, Temperatur), Kurzschluss nach Plus oder Leitungsunterbrechung. 0 -
0x8052A5 Passivtank, Sensorsignal PWM (Level, Temperatur), Kurzschluss nach Masse. 0 -
0x8052A6 Aktivtank, Level-Quality-Sensor, Fehler im Direkt-Piezo. 0 -
0x8052A7 Aktivtank, Level-Quality-Sensor, Fehler im Kombi-Piezo. 0 -
0x8052A8 Aktivtank, Level-Quality-Sensor, Fehler im Temperatursensor. 0 -
0x8052A9 Aktivtank, Level-Quality-Sensor, Fehler im ASIC. 0 -
0x8052AA Aktivtank, Level-Quality-Sensor, Offset zu Referenztemperatur zu groß (positiv). 0 -
0x8052AB Aktivtank, Level-Quality-Sensor, Offset zu Referenztemperatur zu groß (negativ). 0 -
0x8052AC Aktivtank, Drucksensor, Offset zu Referenztemperatur zu groß (positiv). 0 -
0x8052AD Aktivtank, Drucksensor, Offset zu Referenztemperatur zu groß (negativ). 0 -
0x8052AE Dosierventil, Spulentemperatur, Offset zu Referenztemperatur zu groß (positiv). 0 -
0x8052AF Dosierventil, Spulentemperatur, Offset zu Referenztemperatur zu groß (negativ). 0 -
0x8052B0 Systemdruck, Druckabbaufehler. 0 -
0x8052B1 Systemdruck, Druckaufbaufehler. 0 -
0x8052B3 Systemdruck, Druck vor Motorstart zu niedrig. 0 -
0x8052B4 Systemdruck, Druck vor Motorstart zu hoch. 0 -
0x8052B7 Systemdruck, Leckageerkennung, Systemdruck nach Dosierpause zu niedrig. 0 -
0x8052B8 Systemdruck, Überdruckfehler im Dosierbetrieb. 0 -
0x8052B9 Systemdruck, Unterdruckfehler im Dosierbetrieb. 0 -
0x8052BC Passivtank, Sensorsignal PWM (Level), Signal Range Check, high. 0 -
0x8052BD Passivtank, Sensorsignal PWM (Level), Signal Range Check, low. 0 -
0x8052BE Passivtank, Sensorsignal PWM (Temperatur), Signal Range Check, high. 0 -
0x8052BF Passivtank, Sensorsignal PWM (Temperatur), Signal Range Check, low. 0 -
0x8052C0 Transferpumpe, Fördermenge ungenügend (Füllstand im Aktivtank steigt nicht). 0 -
0x8052C1 Transferpumpe, High Side, Kurzschluss nach Masse. 0 -
0x8052C2 Transferpumpe, High Side, Kurzschluss nach Plus. 0 -
0x8052C3 Transferpumpe, Leitungsunterbrechung. 0 -
0x8052C4 Transferpumpe, Low Side, Kurzschluss nach Masse. 0 -
0x8052C5 Transferpumpe, Low Side, Kurzschluss nach Plus. 0 -
0x8052C6 Systemleckage, Aktivtankfüllstand gemäß eindosierter Menge zu niedrig. 0 -
0x8052C7 Dosiermengenabweichung, dosierte Menge gemäß Aktivtankfüllstand zu gering. 0 -
0x8052C8 Dosiermengenabweichung, dosierte Menge gemäß Aktivtankfüllstand zu hoch. 0 -
0x8052C9 Aktivtank, AdBlue-Qualität, Signal ohne Veränderung. 0 -
0x8052CA Aktivtank, Förderpumpe, Geschwindigkeitsregler am Anschlag. 0 -
0x8052CB Aktivtank, Datencheckfehler SENT_2 slow channel (Druck, Temperatur_2). 0 -
0x8052CD Aktivtank, Kommunikationsfehler SENT_2 slow channel (Druck, Temperatur_2). 0 -
0x8052CE Aktivtank, Signalfehler SENT_2 slow channel (Druck, Temperatur_2). 0 -
0x8052D0 Aktivtank, Förderpumpe fördert Luft. 0 -
0x8052D1 Aktivtank, Drucksensor, Messwert Druck unplausibel. 0 -
0x8052D2 Systemdruck, Blockage zwischen Förderpumpe und Dosierventil. 0 -
0x8052D3 Dosierbereitschaft zu spät (TTCL) oder unplausibel entfallen. 0 -
0x8052D4 Aktivtank, Drucksensor, Messwert Temperatur_2 unplausibel (slow channel). 0 -
0x8052D5 Aktivtank, Drucksensor, Messwert Temperatur_2 unplausibel (fast channel). 0 -
0x8052D6 Dosierventil blockiert. 0 -
0x8052D7 Aktivtank, Level-Quality-Sensor (Direkt-Piezo), Echofehler 0 -
0x8052D8 Aktivtank, Level-Quality-Sensor (Kombi-Piezo), Echofehler. 0 -
0x8052D9 Aktivtank, Level-Quality-Sensor (Direkt-Piezo), Signal zu hoch. 0 -
0x8052DA Aktivtank, Level-Quality-Sensor, Qualitätssignal nicht verfügbar. 0 -
0x8052DB Aktivtank, Level-Quality-Sensor, Vergleich beider Piezosignale unplausibel. 0 -
0x8052DC Aktivtank, Level-Quality-Sensor, keine Messung verfügbar. 0 -
0x8052DD Aktivtank, Level-Quality-Sensor (Direkt-Piezo), keine Änderung bei dynamischer Fahrt. 0 -
0x8052DE Aktivtank, Level-Quality-Sensor (Kombi-Piezo), keine Änderung bei dynamischer Fahrt. 0 -
0x8052DF Anforderung Warnmeldung. 0 -
0x8052E0 Dosiermengenabweichung, dosierte Menge gemäß Druckstufen zu gering. 0 -
0x8052E1 Dosiermengenabweichung, dosierte Menge gemäß Druckstufen zu hoch. 0 -
0x8052E2 Dosiermengenabweichung, dosierte Menge zu gering, Summenfehler. 0 -
0x8052E3 Dosiermengenabweichung, dosierte Menge zu hoch, Summenfehler. 0 -
0x8052E4 Dosierunterbrechung zur Diagnose einer Dosiermengenabweichung (dosierte Menge zu gering). 0 -
0x8052E5 Dosierunterbrechung zur Diagnose einer Dosiermengenabweichung (dosierte Menge zu hoch). 0 -
0x805350 SCR-Steuergerät, 5V-Ausgang, Überspannung. 0 -
0x805351 SCR-Steuergerät, 5V-Ausgang, Unterspannung. 0 -
0x805352 SCR-Steuergerät, 12V-Ausgang, Überspannung. 0 -
0x805354 SCR-Steuergerät, 12V-Ausgang, Unterspannung. 0 -
0x805355 SCR-Steuergerät, Klemme 30 (Heizerversorgung), Überspannung. 0 -
0x805356 SCR-Steuergerät, Klemme 30 (Heizerversorgung), Unterspannung. 0 -
0x805357 SCR-Steuergerät, Klemme 30B (Logik, Sensorik, Dosierventil, Pumpenversorgung), Überspannung. 0 -
0x805358 SCR-Steuergerät, Klemme 30B (Logik, Sensorik, Dosierventil, Pumpenversorgung), Unterspannung. 0 -
0x805359 Aktivtank, Förderpumpe, Strom zu hoch. 0 -
0x80535A SCR-Steuergerät, Transferpumpe High Side, Mosfet offen. 0 -
0x80535B SCR-Steuergerät, Transferpumpe Low Side, Mosfet offen. 0 -
0x80535C SCR-Steuergerät, Endstufe Förderpumpe, SPI-Kommunikation gestört. 0 -
0x80535D SCR-Steuergerät, Endstufen Low Sides, SPI-Kommunikation gestört. 0 -
0x80535E SCR-Steuergerät, 12V-Ausgang, Kurzschluss nach Plus. 0 -
0x80535F SCR-Steuergerät, 12V-Ausgang, Kurzschluss nach Masse. 0 -
0x805360 SCR-Steuergerät, Dosierventil High Side, Mosfet offen. 0 -
0x805362 SCR-Steuergerät, Dosierventil Low Side, Mosfet offen. 0 -
0x805363 SCR-Steuergerät, Dosierventil Low Side, Mosfet Kurzschluss. 0 -
0x805364 SCR-Steuergerät, Heizung High Side, Mosfet offen. 0 -
0x805365 SCR-Steuergerät, Aktivtankheizung Low Side, Mosfet offen. 0 -
0x805366 SCR-Steuergerät, Aktivtankheizung Low Side, Mosfet Kurzschluss. 0 -
0x805367 SCR-Steuergerät, Dosierleitungsheizung Low Side, Mosfet offen. 0 -
0x805368 SCR-Steuergerät, Dosierleitungsheizung Low Side, Mosfet Kurzschluss. 0 -
0x80536A SCR-Steuergerät, RAM-Fehler. 0 -
0x80536B SCR-Steuergerät, Checksummenfehler Bootloader Continental. 0 -
0x80536C SCR-Steuergerät, Checksummenfehler Bootloader BMW. 0 -
0x80536D SCR-Steuergerät, Checksummenfehler Programmstand. 0 -
0x80536E SCR-Steuergerät, Checksummenfehler Datenstand. 0 -
0x805371 SCR-Steuergerät, Montagemodus aktiv. 0 -
0x805372 SCR-Steuergerät, Nachlauf gestört. 0 -
0x805373 SCR-Steuergerät, Nachlauf nicht abgeschlossen. 0 -
0x805375 Fahrzeugstatus nicht plausibel zu Klemmenstatus bzw. PWF-Zustand. 0 -
0x805377 OBD-relevanter Fehler im Fahrzyklus erkannt aber nicht im nichtflüchtigen Speicher gesichert. 0 -
0x80537A Motorabstellzeit, Summenfehler für Plausibilisierungen. 0 -
0x80537B Motorabstellzeit, unplausibel bei Motorstart nach abgeschlossenem SCR-Nachlauf. 0 -
0x80537C Motorabstellzeit, unplausibel bei laufendem Motor. 0 -
0x80537D Motorabstellzeit, unplausibel bei Motorstart während SCR-Nachlauf. 0 -
0x80537E Motorabstellzeit, unplausibel zu Motorabstellzeit der DDE. 0 -
0xCBC401 FA-CAN Physikalischer Busfehler 0 -
0xCBC40A FA-CAN Control Module Bus OFF 0 -
0xCBC469 LP-CAN Physikalischer Busfehler 0 -
0xCBC472 LP-CAN Control Module Bus OFF 0 -
0xCBCBFF Dummy-Fehlerspeichereintrag im Netzwerkfehlerbereich nur für Testzwecke 1 -
0xCBD400 Botschaft fehlt: Längsbeschleunigung Schwerpunkt, 0x199, Sender DSC_Modul. 1 -
0xCBD401 Botschaft fehlt: Querbeschleunigung Schwerpunkt, 0x19A, Sender DSC_Modul. 1 -
0xCBD403 Botschaft fehlt: Drehmoment Kurbelwelle 1, 0xA5, Sender Sender DME1. 1 -
0xCBD404 Botschaft fehlt: Geschwindigkeit Fahrzeug, 0x1A1, Sender DSC_Modul. 1 -
0xCBD405 Botschaft fehlt: Kilometerstand/Reichweite, 0x330, Sender Kombi/IKE. 1 -
0xCBD406 Botschaft fehlt: Daten Antriebsstrang 2, 0x3F9, Sender DME1. 1 -
0xCBD407 Botschaft fehlt: Daten Antriebsstrang 1, 0x3FB, Sender DME1. 1 -
0xCBD408 Botschaft fehlt: Bereitstellung Daten SCR, 0x188, Sender DME1. 1 -
0xCBD409 Botschaft fehlt: Anforderung Bereitstellung SCR-Additiv, 0x84, Sender DME1. 1 -
0xCBD40A Botschaft fehlt: Außentemperatur, 0x2CA, Sender Kombi/IKE. 1 -
0xCBD40B Botschaft fehlt: Relativzeit BN2020, 0x328, Sender Kombi/IKE. 1 -
0xCBD40C Botschaft fehlt: Temperatur Daten Motor, 0x2CB, Sender DME1. 1 -
0xCBD40E Botschaft fehlt: Diagnose OBD Motor, 0x397, Sender DME1. 1 -
0xCBD40F Botschaft fehlt: Klemmen, 0x12F, Sender BDC. 1 -
0xCBD410 Botschaft fehlt: Fahrzeugzustand, 0x3A0, Sender BDC/BDC_2015. 1 -
0xCBD411 Botschaft fehlt: Zustand Fahrzeug (35up), 0x3C, Sender BDC_2015. 1 -
0xCBD412 Botschaft fehlt: Status Verbrauch Kraftstoff Motor, 0x2C4, Sender DME1. 1 -
0xCBD413 Botschaft fehlt: Status Motor Betrieb, 0x3DE, Sender DME1. 1 -
0xCBD420 Signalfehler: Soll_Bereitstellung_Einspritzmenge_SCR-Additiv (TAR_RESG_IJV_SCRA), Sender DME1. 1 -
0xCBD422 Signalfehler: Status_Abgas_Massenstrom (ST_EXH_MFLOW), Sender DME1. 1 -
0xCBD423 Signalfehler: Status_Initialisierung_Filter_Wert_DME (ST_INIT_FIL_VL_DME), Sender DME1. 1 -
0xCBD424 Signalfehler: Temperatur_Außen (TEMP_EX), Sender Kombi/IKE. 1 -
0xCBD427 Signalfehler: Luftdruck_Motor_Antrieb (AIP_ENG_DRVI), Sender DME1. 1 -
0xCBD428 Signalfehler: Temperatur_Motor_Antrieb (TEMP_ENG_DRV), Sender DME1. 1 -
0xCBD429 Signalfehler: Status_Antrieb_Fahrzeug (ST_DRV_VEH), Sender DME1. 1 -
0xCBD42A Signalfehler: Status_OBD-Zyklus (ST_OBD_CYC), Sender DME1. 1 -
0xCBD42B Signalfehler: OBD_Position_Drosselklappe_Motor (OBD_PO_THVA_ENG), Sender DME1. 1 -
0xCBD42C Signalfehler: OBD_Modellwert_Last_Motor (OBD_CALCVL_LD_ENG), Sender DME1. 1 -
0xCBD42D Signalfehler: Ist_Drehmoment_Kurbelwelle (AVL_TORQ_CRSH), Sender DME1. 1 -
0xCBD42E Signalfehler: Ist_Drehzahl_Motor_Kurbelwelle (AVL_RPM_ENG_CRSH), Sender DME1. 1 -
0xCBD42F Signalfehler: Status_Sperre_Fehlerspeicher_FZM (ST_ILK_ERRM_FZM), Sender BDC/BDC2015. 1 -
0xCBD430 Signalfehler: Geschwindigkeit_Fahrzeug_Schwerpunkt (V_VEH_COG), Sender DSC_Modul. 1 -
0xCBD431 Signalfehler: Wegstrecke_Kilometer (MILE_KM), Sender Kombi/IKE. 1 -
0xCBD432 Signalfehler: Status_Diagnose_Verdampfer_Zyklus (ST_DIAG_EVA_CYC), Sender DME1. 1 -
0xCBD433 Signalfehler: Status_Klemme (ST_KL), Sender BDC. 1 -
0xCBD434 Signalfehler: Längsbeschleunigung_Schwerpunkt (ACLNX_COG), Sender DSC_Modul. 1 -
0xCBD435 Signalfehler: Qualifier_Längsbeschleunigung_Schwerpunkt (QU_ACLNX_COG), Sender DSC_Modul. 1 -
0xCBD436 Signalfehler: Querbeschleunigung_Schwerpunkt (ACLNY_COG), Sender DSC_Modul. 1 -
0xCBD437 Signalfehler: Qualifier_Querbeschleunigung_Schwerpunkt (QU_ACLNY_COG), Sender DSC_Modul. 1 -
0xCBD438 Signalfehler: Zeit_Sekunde_Zähler_Relativ (T_SEC_COU_REL), Sender Kombi/IKE. 1 -
0xCBD439 Signalfehler: Temperatur_SCR-Katalysator (TEMP_SCAT), Sender DME1. 1 -
0xCBD43B Signalfehler: Temperatur_Kraftstoff (TEMP_FU), Sender DME1. 1 -
0xCBD43C Signalfehler: Drehmoment_Fahrerwunsch_PID_SCR-System (TORQ_DVCH_PID_SCRS), Sender DME1. 1 -
0xCBD43D Signalfehler: Drehmoment_Aktuelle_PID_SCR-System (TORQ_PRES_PID_SCRS), Sender DME1. 1 -
0xCBD43E Signalfehler: Status_Zustand_Fahrzeug (ST_CON_VEH), Sender BDC_2015. 1 -
0xCBD43F Signalfehler: Einspritzmenge_Kraftstoff_Motor (INJV_FU_ENG), Sender DME1. 1 -
0xCBD443 Signalfehler: Qualifier_Ist_Drehzahl_Motor_Kurbelwelle (QU_AVL_RPM_ENG_CRSH), Sender DME1. 1 -
0xCBD444 Signalfehler: Qualifier_Geschwindigkeit_Fahrzeug_Schwerpunkt (QU_V_VEH_COG), Sender DSC_Modul. 1 -
0xCBD445 Signalfehler: Steuerung_Basis_Teilnetze (CTR_BS_PRTNT), Sender BDC2015. 1 -
0xCBD446 Signalfehler: Restlaufleistung_SCR-Additv (RMMI_SCRA), Sender DME1. 1 -
0xCBD447 Signalfehler: Status_FID_SCR-System (ST_FID_SCRS), Sender DME1. 1 -
0xCBD448 Signalfehler: Motor_Aus_Zeit (ENG_OFF_T), Sender DME1. 1 -
0xCBD449 Signalfehler: Status_Motor_Aus_Zeit (ST_ENG_OFF_T), Sender DME1. 1 -
0xFFFFFF unbekannter Fehlerort 0 -

FUMWELTTEXTE

Dimensions: 181 rows × 9 columns

UWNR UWTEXT UW_EINH L/H UWTYP NAME MUL DIV ADD
0x1750 F_UW_BN - High unsigned char - 1.0 1.0 0.0
0xD28D UWB_CAN_RX_MOTOR_AUS_ZEIT min High unsigned int - 1.0 1.0 0.0
0xD28E UWB_CAN_RX_STATUS_MOTOR_AUS_ZEIT 0-n High 0xFFFF TAB_CAN_RX_STATUS_MOTOR_AUS_ZEIT - - -
0xD28F UWB_CAN_RX_STATUS_FID_SCR_SYSTEM - High unsigned int - 1.0 1.0 0.0
0xD2B7 UWB_CAN_RX_SOLL_BEREITSTELLUNG_EINSPRITZMENGE_SCR_ADDITIV g High unsigned int - 0.001 1.0 0.0
0xD2B9 UWB_CAN_RX_STATUS_ABGAS_MASSENSTROM kg/h High unsigned int - 0.0625 1.0 0.0
0xD2BB UWB_CAN_RX_TEMPERATUR_AUSSEN °C High signed int - 0.0078125 1.0 0.0
0xD2BE UWB_CAN_RX_LUFTDRUCK_MOTOR_ANTRIEB hPa High unsigned int - 0.08291752 1.0 0.0
0xD2BF UWB_CAN_RX_TEMPERATUR_MOTOR_ANTRIEB °C High unsigned int - 1.0 1.0 -40.0
0xD2C4 UWB_CAN_RX_IST_DREHMOMENT_KURBELWELLE Nm High signed int - 0.03125 1.0 0.0
0xD2C5 UWB_CAN_RX_IST_DREHZAHL_MOTOR_KURBELWELLE 1/min High unsigned int - 1.0 1.0 0.0
0xD2C6 UWB_CAN_RX_STATUS_SPERRE_FEHLERSPEICHER_FZM 0-n High 0xFFFF STATUS_SPERRE_FEHLERSPEICHER_FZM - - -
0xD2C7 UWB_CAN_RX_GESCHWINDIGKEIT_FAHRZEUG_SCHWERPUNKT km/h High unsigned int - 1.0 1.0 0.0
0xD2CA UWB_CAN_RX_STATUS_KLEMME - High unsigned int - 1.0 1.0 0.0
0xD2CB UWB_CAN_RX_LAENGSBESCHLEUNIGUNG_SCHWERPUNKT m/s² High signed int - 0.0008475 1.0 0.0
0xD2CC UWB_CAN_RX_QUALIFIER_LAENGSBESCHLEUNIGUNG_SCHWERPUNKT - High unsigned int - 1.0 1.0 0.0
0xD2CD UWB_CAN_RX_QUERBESCHLEUNIGUNG_SCHWERPUNKT m/s² High signed int - 0.0008475 1.0 0.0
0xD2CE UWB_CAN_RX_QUALIFIER_QUERBESCHLEUNIGUNG_SCHWERPUNKT - High unsigned int - 1.0 1.0 0.0
0xD2D0 UWB_CAN_RX_TEMPERATUR_SCR_KATALYSATOR °C High unsigned int - 0.0625 1.0 -273.15
0xD2D2 UWB_CAN_RX_TEMPERATUR_KRAFTSTOFF °C High unsigned int - 1.0 1.0 -50.0
0xD2DF UWB_CAN_RX_RESTLAUFLEISTUNG_SCR_ADDITIV km High unsigned int - 1.0 1.0 0.0
0xD2E0 UWB_CAN_TX_ANFORDERUNG_MIL_DIAGNOSE_OBD_SCR 0-n High 0xFFFF ANFORDERUNG_MIL_DIAGNOSE_OBD_SCR - - -
0xD2E1 UWB_CAN_TX_STATUS_SYSTEM_FEHLER_OBD_SCR - High unsigned int - 1.0 1.0 0.0
0xD2E2 UWB_CAN_TX_STATUS_SPERRE_SYR_SYSTEM - High unsigned int - 1.0 1.0 0.0
0xD2E3 UWB_CAN_TX_IST_BEREITSTELLUNG_EINSPRITZMENGE_SCR_ADDITIV g High unsigned int - 0.001 1.0 0.0
0xD2E4 UWB_CAN_TX_LIM_BEREITSTELLUNG_EINSPRITZMENGE_SCR_ADDITIV mg/s High unsigned int - 0.0625 1.0 0.0
0xD2E5 UWB_CAN_TX_STATUS_BEREITSTELLUNG_SCR_ADDITIV - High unsigned int - 1.0 1.0 0.0
0xD2E9 UWB_CAN_TX_STATUS_RESTLAUFLEISTUNG_SCR_ADDITIV km High unsigned int - 1.0 1.0 0.0
0xD3F9 UWB_CAN_TX_STATUS_IST_QUALITAET_SCR_ADDITIV 0-n High 0xFFFF TAB_CAN_TX_STATUS_IST_QUALITAET_SCR_ADDITIV - - -
0xD3FB UWB_CAN_TX_IST_STROM_VERBRAUCHER_FEPM A High unsigned int - 1.0 1.0 0.0
0xD46B UWB_FOERDERPUMPE_FEHLER_HIGH_BYTE - High unsigned int - 1.0 1.0 0.0
0xD46C UWB_FOERDERPUMPE_FEHLER_LOW_BYTE - Low unsigned int - 1.0 1.0 0.0
0xD46D UWB_DWIS_ANFORDERUNG_CCM - High unsigned int - 1.0 1.0 0.0
0xD46E UWB_DWIS_ANFORDERUNG_GRUPPE - High unsigned int - 1.0 1.0 0.0
0xD48F UWB_AKTIVTANKHEIZUNG_PWM % High unsigned int - 0.00610352 1.0 0.0
0xD490 UWB_DOSIERLEITUNGSHEIZUNG_PWM % High unsigned int - 0.00610352 1.0 0.0
0xD491 UWB_AKTIVTANKHEIZUNG_AKTIV 0/1 High 0x0001 - - - -
0xD492 UWB_DOSIERLEITUNGSHEIZUNG_AKTIV 0/1 High 0x0001 - - - -
0xD493 UWB_AKTIVTANKHEIZUNG_STROM_ROHWERT V High unsigned int - 0.00015258 1.0 0.0
0xD494 UWB_DOSIERLEITUNGSHEIZUNG_STROM_ROHWERT V High unsigned int - 0.00015258 1.0 0.0
0xD495 UWB_AKTIVTANKHEIZUNG_STROM A High unsigned int - 0.00097656 1.0 0.0
0xD496 UWB_DOSIERLEITUNGSHEIZUNG_STROM A High unsigned int - 0.00097656 1.0 0.0
0xD497 UWB_AKTIVTANKHEIZUNG_LEISTUNG W High unsigned int - 0.1 1.0 0.0
0xD498 UWB_DOSIERLEITUNGSHEIZUNG_LEISTUNG W High unsigned int - 0.1 1.0 0.0
0xD49B UWB_FOERDERPUMPE_STROM A High unsigned int - 0.001 1.0 0.0
0xD49C UWB_FOERDERPUMPE_DREHZAHL 1/min High unsigned int - 1.0 1.0 0.0
0xD49D UWB_DRUCKREGELUNG_AKTIV 0/1 High 0x0001 - - - -
0xD49E UWB_DRUCKREGELUNG_GEPRUEFT 0/1 High 0x0001 - - - -
0xD49F UWB_DOSIERLEITUNG_FUELLUNGSGRAD_NACH_RUECKSAUGEN ml High unsigned int - 0.01 1.0 0.0
0xD4A0 UWB_TEMPERATUR_LEVELSENSOR_AKTIVTANK_ROHWERT °C High unsigned int - 0.0625 1.0 -273.15
0xD4A1 UWB_TEMPERATUR_AKTIVTANK °C High unsigned int - 0.0625 1.0 -273.15
0xD4A2 UWB_TEMPERATUR_DRUCKSENSOR_ROHWERT °C High unsigned int - 0.0625 1.0 -273.15
0xD4A3 UWB_FOERDERPUMPE_DREHZAHL_SOLLWERT 1/min High unsigned int - 1.0 1.0 0.0
0xD4A4 UWB_DRUCK_ROHWERT bar High signed int - 0.00097656 1.0 0.0
0xD4A5 UWB_DRUCK_GEFILTERT bar High signed int - 0.00097656 1.0 0.0
0xD4A6 UWB_DRUCK_NOMINAL bar High signed int - 0.00097656 1.0 0.0
0xD4A7 UWB_DRUCK_ABWEICHUNG_VON_NOMINAL bar High signed int - 0.00097656 1.0 0.0
0xD4A8 UWB_SCHALLGESCHWINDIGKEIT_ROHWERT m/s High unsigned int - 0.1 1.0 0.0
0xD4A9 UWB_QUALITAET_ROHWERT % High unsigned int - 0.01 1.0 -10.0
0xD4AA UWB_QUALITAET % High unsigned int - 0.01 1.0 -10.0
0xD4AB UWB_LEVELSENSOR_AKTIVTANK_FEHLER - High unsigned int - 1.0 1.0 0.0
0xD4AC UWB_LEVELSIGNAL_GUELTIG_AKTIVTANK_DIREKT_PIEZO 0/1 High 0x0001 - - - -
0xD4AD UWB_LEVELSIGNAL_GUELTIG_AKTIVTANK_KOMBI_PIEZO 0/1 High 0x0001 - - - -
0xD4AE UWB_FUELLSTAND_AKTIVTANK_DIREKT_PIEZO_ROHWERT mm High unsigned int - 0.01 1.0 0.0
0xD4AF UWB_FUELLSTAND_AKTIVTANK_KOMBI_PIEZO_ROHWERT mm High unsigned int - 0.01 1.0 0.0
0xD4B0 UWB_FUELLSTAND_AKTIVTANK_DIREKT_PIEZO mm High unsigned int - 0.01 1.0 0.0
0xD4B1 UWB_FUELLSTAND_AKTIVTANK_KOMBI_PIEZO mm High unsigned int - 0.01 1.0 0.0
0xD4B2 UWB_AMPLITUDE_ECHO_1_DIREKT_PIEZO - High unsigned int - 0.1 1.0 0.0
0xD4B3 UWB_AMPLITUDE_ECHO_1_KOMBI_PIEZO - High unsigned int - 0.1 1.0 0.0
0xD4B4 UWB_AMPLITUDE_ECHO_2_KOMBI_PIEZO - High unsigned int - 0.1 1.0 0.0
0xD4B5 UWB_AMPLITUDE_ECHO_3_KOMBI_PIEZO - High unsigned int - 0.1 1.0 0.0
0xD4B6 UWB_FUELLMENGE_AKTIVTANK_DIREKT_PIEZO_UNGEFILTERT l High unsigned int - 0.1 1.0 0.0
0xD4B7 UWB_FUELLMENGE_AKTIVTANK_KOMBI_PIEZO_UNGEFILTERT l High unsigned int - 0.1 1.0 0.0
0xD4C3 UWB_BATTERIESPANNUNG_SCR V High signed int - 0.01953125 1.0 0.0
0xD4D0 UWB_FUELLMENGE_AKTIVTANK_SCHNELL_GEFILTERT l High unsigned int - 0.00097656 1.0 0.0
0xD4D1 UWB_FUELLMENGE_AKTIVTANK_LANGSAM_GEFILTERT l High unsigned int - 0.00097656 1.0 0.0
0xD4D2 UWB_FUELLMENGE_AKTIVTANK_RELATIV % High unsigned int - 0.39215686 1.0 0.0
0xD4D3 UWB_NACHFUELLBARE_MENGE_AKTIVTANK_GEFILTERT l High unsigned int - 0.00097656 1.0 0.0
0xD4D4 UWB_FREIGABEMASKE_FUER_FUELLSTANDSFUNKTION_AKTIVTANK - High unsigned int - 1.0 1.0 0.0
0xD4D6 UWB_NACHTANKERKENNUNG 0/1 High 0x0001 - - - -
0xD4D7 UWB_AUFTAUZEIT_AKTUELL s High unsigned int - 0.1 1.0 0.0
0xD4D8 UWB_AUFTAUZEIT_VORGABE s High unsigned int - 0.1 1.0 0.0
0xD4D9 UWB_AUFTAUZEIT_EPA s High unsigned int - 0.1 1.0 0.0
0xD4DA UWB_AUFTAUEN_AKTIV 0/1 High 0x0001 - - - -
0xD4DB UWB_AUFTAUEN_ABGESCHLOSSEN 0/1 High 0x0001 - - - -
0xD4DC UBW_TEMPERATUR_AKTIVTANK_GESPEICHERT °C High unsigned int - 0.0625 1.0 -273.15
0xD4DE UWB_AKTIVTANK_GEFROREN 0/1 High 0x0001 - - - -
0xD4DF UWB_LEVELSENSOR_PASSIVTANK_ANZAHL_ECHOS - High unsigned int - 1.0 1.0 0.0
0xD4E1 UWB_TEMPERATUR_PASSIVTANK °C High unsigned int - 0.0625 1.0 -273.15
0xD4E4 UWB_FREIGABEMASKE_FUER_FUELLSTANDSFUNKTION_PASSIVTANK - High unsigned int - 1.0 1.0 0.0
0xD4E5 UWB_NACHFUELLBARE_MENGE_PASSIVTANK_GEFILTERT l High unsigned int - 0.00097656 1.0 0.0
0xD4E6 UWB_PASSIVTANK_VERBAUT 0/1 High 0x0001 - - - -
0xD4E7 UWB_LANGZEIT_UMPUMPMENGE l High unsigned int - 0.1 1.0 0.0
0xD4E8 UWB_TEMPERATUR_SCR_STEUERGERAET °C High unsigned int - 0.75 1.0 -48.0
0xD4E9 UWB_ZUSTAND_SCR_SYSTEM - High unsigned int - 1.0 1.0 0.0
0xD4EA UWB_NACHLAUF_GESTARTET 0/1 High 0x0001 - - - -
0xD4EC UWB_NACHLAUF_AKTIV 0/1 High 0x0001 - - - -
0xD4ED UWB_NACHLAUF_ABGESCHLOSSEN 0/1 High 0x0001 - - - -
0xD4EE UWB_NACHLAUFZEIT s High unsigned int - 0.1 1.0 0.0
0xD4EF UWB_ZEIT_SEIT_MOTORSTOPP min High unsigned int - 1.0 1.0 0.0
0xD4F0 UWB_ZEIT_SEIT_MOTORSTART s High unsigned int - 0.1 1.0 0.0
0xD4F1 UWB_TEMPERATUR_DOSIERVENTIL °C High unsigned int - 0.0625 1.0 -273.15
0xD4F2 UWB_WIDERSTAND_DOSIERVENTIL_GEMESSEN Ohm High unsigned int - 0.00195313 1.0 0.0
0xD4F3 UWB_WIDERSTAND_DOSIERVENTIL_OFFSET_ROHWERT Ohm High signed int - 0.00195313 1.0 0.0
0xD4F4 UWB_WIDERSTAND_DOSIERVENTIL_OFFSETWERT Ohm High signed int - 0.00195313 1.0 0.0
0xD4F5 UWB_STROM_DOSIERVENTIL A High unsigned int - 0.00097656 1.0 0.0
0xD4F6 UWB_TASTVERHAELTNIS_DOSIERVENTIL_ANFORDERUNG % High unsigned int - 0.00610352 1.0 0.0
0xD4F7 UWB_FREQUENZ_DOSIERVENTIL_ANFORDERUNG Hz High unsigned int - 0.015625 1.0 0.0
0xD4F9 UWB_MASSENSTROM_DOSIERVENTIL mg/s High unsigned int - 0.015625 1.0 0.0
0xD4FA UWB_LANGZEIT_DOSIERMENGE g High unsigned int - 32.768 1.0 0.0
0xD4FB UWB_DOSIERVENTIL_FEHLER - High unsigned int - 1.0 1.0 0.0
0xD4FE UWB_KILOMETER_AKTUELLER_DC km High unsigned int - 0.1 1.0 0.0
0xD4FF UWB_ZEITDAUER_UEBERTEMPERATUR_DOSIERVENTIL s High unsigned int - 1.0 1.0 0.0
0xD6E0 UWB_LAUFZEIT_ECHO_1_DIREKT_PIEZO µs High unsigned int - 0.015625 1.0 0.0
0xD6E1 UWB_LAUFZEIT_ECHO_1_KOMBI_PIEZO µs High unsigned int - 0.015625 1.0 0.0
0xD6E2 UWB_LAUFZEIT_ECHO_2_KOMBI_PIEZO µs High unsigned int - 0.015625 1.0 0.0
0xD6E3 UWB_LAUFZEIT_ECHO_3_KOMBI_PIEZO µs High unsigned int - 0.015625 1.0 0.0
0xD6E4 UWB_SIGNALGUETE_ECHO_1_DIREKT_PIEZO - High unsigned int - 1.0 1.0 0.0
0xD6E5 UWB_SIGNALGUETE_ECHO_1_KOMBI_PIEZO - High unsigned int - 1.0 1.0 0.0
0xD6E6 UWB_SIGNALGUETE_ECHO_2_KOMBI_PIEZO - High unsigned int - 1.0 1.0 0.0
0xD6E7 UWB_SIGNALGUETE_ECHO_3_KOMBI_PIEZO - High unsigned int - 1.0 1.0 0.0
0xD6E8 UWB_ZEIT_REHEATING s High unsigned int - 1.0 1.0 0.0
0xD6EA UWB_FUELLSTAND_PASSIVTANK_ROHWERT mm High unsigned int - 0.25 1.0 0.0
0xD6EB UWB_FUELLMENGE_PASSIVTANK_RELATIV % High unsigned int - 0.5 1.0 0.0
0xD6EC UWB_FUELLMENGE_PASSIVTANK_ROHWERT l High unsigned int - 0.1 1.0 0.0
0xD6ED UWB_FUELLMENGE_PASSIVTANK_SCHNELL_GEFILTERT l High unsigned int - 0.00097656 1.0 0.0
0xD6EF UWB_FUELLMENGE_PASSIVTANK_LANGSAM_GEFILTERT l High unsigned int - 0.00097656 1.0 0.0
0xD6F0 UWB_ERSTBEFUELLUNGSSTATUS 0/1 High 0x0001 - - - -
0xD6F2 UWB_LERNWERT_FOERDERPUMPE µl High unsigned int - 0.1 1.0 0.0
0xD6F3 UWB_TEMPERATUR_DOSIERVENTIL_MAXIMAL °C High unsigned int - 0.0625 1.0 -273.15
0xD6F7 UWB_PRODUKTIONSDATUM_LQS HEX High unsigned int - - - -
0xD6FB UWB_KAVITAETSERKENNUNG_GUELTIG 0/1 High 0x0001 - - - -
0xD7C1 UWB_CDM2_SUMME_NACHFUELLMENGE l High unsigned int - 0.00097656 1.0 0.0
0xD7C2 UWB_TEMPERATUR_FOERDERPUMPE °C High unsigned int - 0.0625 1.0 -273.15
0xD7C4 UWB_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_GEFILTERT µl High unsigned int - 0.1 1.0 0.0
0xD7C5 UWB_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_ERSTER µl High unsigned int - 0.1 1.0 0.0
0xD7C6 UWB_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_REFERENZ µl High unsigned int - 0.1 1.0 0.0
0xD7D4 UWB_DOSIERMENGE_AKTUELLER_DC mg High unsigned int - 16.0 1.0 0.0
0xD7D5 UWB_FOERDERPUMPE_PWM_SOLL % High unsigned int - 0.00610352 1.0 0.0
0xD7D6 UWB_FOERDERPUMPE_PWM_IST % High unsigned int - 0.00610352 1.0 0.0
0xD7D8 UWB_CDM2_VERBRAUCH_IST_ZU_SOLL % High signed int - 0.1 1.0 0.0
0xD7DA UWB_CDM2_FUELLMENGE_AKTIVTANK_ENDE l High unsigned int - 0.00097656 1.0 0.0
0xD7DB UWB_CDM2_FUELLMENGE_AKTIVTANK_ANFANG l High unsigned int - 0.00097656 1.0 0.0
0xD7DC UWB_TEMPERATUR_ABGAS_DOSIERVENTIL °C High signed int - 0.0625 1.0 0.0
0xD7DE UWB_TEMPERATUR_DRUCKSENSOR_CROSSCHECK °C High unsigned int - 0.0625 1.0 -273.15
0xD7DF UWB_TEMPERATUR_LEVELSENSOR_AKTIVTANK_CROSSCHECK °C High unsigned int - 0.0625 1.0 -273.15
0xD7EE UWB_TEMPERATUR_DOSIERVENTIL_CROSSCHECK °C High signed int - 0.0078125 1.0 0.0
0xD7EF UWB_SYSTEMLECKAGE_DIAGNOSE - High unsigned int - 0.03125 1.0 0.0
0xD810 UWB_SYSTEMLECKAGE_GEMESSEN - High unsigned int - 0.03125 1.0 0.0
0xD812 UWB_VOLUMENSTROM_ANGEFORDERT - High unsigned int - 1.0 1.0 0.0
0xD813 UWB_CDM1_VERBRAUCH_IST_ZU_SOLL % High signed int - 0.1 1.0 0.0
0xD814 UWB_DOSIERVENTIL_SPANNUNG_HIGH_SIDE V High unsigned int - 0.00015258 1.0 0.0
0xD815 UWB_DOSIERVENTIL_SPANNUNG_LOW_SIDE V High unsigned int - 0.00015258 1.0 0.0
0xD816 UWB_SPANNUNG_KLEMME_30B_LOGIK V High signed int - 0.01953125 1.0 0.0
0xD818 UWB_SPANNUNG_KLEMME_30_HEIZER V High signed int - 0.01953125 1.0 0.0
0xD826 UWB_DRUCKSENSOR_DATEN_FAST_CHANNEL - High unsigned int - 1.0 1.0 0.0
0xD827 UWB_DRUCKSENSOR_FEHLER - High unsigned int - 1.0 1.0 0.0
0xD828 UWB_LECKAGE_FUELLSTANDSBASIERT_BITFELD - High unsigned int - 1.0 1.0 0.0
0xD829 UWB_CDM3_DOSIERMENGENABWEICHUNG_RELATIV % High signed int - 0.1 1.0 0.0
0xD82A UWB_CDM3_DOSIERMENGE_IST_AUS_DRUCKSTUFEN mg High unsigned int - 1.0 1.0 0.0
0xD82B UWB_CDM3_DOSIERMENGE_SOLL mg High unsigned int - 1.0 1.0 0.0
0xD82D UWB_SUMME_DRUCKSTUFEN_INJ_BLOCK bar High signed int - 0.00097656 1.0 0.0
0xD82E UWB_SUMME_DRUCKSTUFEN_PUMP_AIR bar High signed int - 0.00097656 1.0 0.0
0xD84E UWB_CDM2_HIGH_RELATIV % High signed int - 0.01 1.0 0.0
0xD84F UWB_CDM2_LOW_RELATIV % High signed int - 0.01 1.0 0.0
0xD854 UWB_LECKAGE_REFERENZ_DOSIERMENGE_INJEKTOR l High unsigned int - 0.00048828 1.0 0.0
0xD855 UWB_CDM2_DOSIERMENGE_AUS_FUELLSTANDSAENDERUNG l High signed int - 0.00097656 1.0 0.0
0xD856 UWB_LECKAGE_DOSIERMENGE_AUS_FUELLSTANDSAENDERUNG l High unsigned int - 0.00048828 1.0 0.0
0xD857 UWB_CDM2_REFERENZ_DOSIERMENGE_INJEKTOR l High unsigned int - 0.00097656 1.0 0.0
0xD858 UWB_CDM2_VOLUMEN_AUS_FUELLSTANDSAENDERUNG l High signed int - 0.00097656 1.0 0.0
0xD8F6 UWB_SYSTEMSTEIFIGKEIT_BERECHNET - High unsigned int - 0.00012207 1.0 0.0
0xD8F7 UWB_SYSTEM_LECKAGE_ADAPTIERT - High unsigned int - 0.03125 1.0 0.0
0xD8F8 UWB_SYSTEM_LECKAGE_CDM1 - High unsigned int - 0.03125 1.0 0.0
0xD8F9 UWB_CDM1_VOLUMEN_AUS_DOSIERANFORDERUNG l High unsigned int - 0.00097656 1.0 0.0
0xD8FA UWB_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_GEFILTERT_2 µl High unsigned int - 0.1 1.0 0.0
0xD8FB UWB_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_ERSTER_2 µl High unsigned int - 0.1 1.0 0.0
0xD8FC UWB_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_REFERENZ_2 µl High unsigned int - 0.1 1.0 0.0
0xE38B UWB_GESAMTDOSIERMENGE_AKTUELLER_DC_TANK_GEFROREN mg High unsigned int - 16.0 1.0 0.0
0xE38C UWB_AKTIVTANKHEIZUNG_LEISTUNG_SETPOINT W High unsigned int - 0.1 1.0 0.0
0xE38D UWB_DOSIERLEITUNGSHEIZUNG_LEISTUNG_SETPOINT W High unsigned int - 0.1 1.0 0.0
0xXYXY unbekannte Umweltbedingung - - - - - - -

IDETAILSTRUKTUR

Dimensions: 5 rows × 2 columns

NAME TYP
F_UWB_ERW ja
SAE_CODE nein
F_HLZ ja
F_SEVERITY nein
F_UWB_SATZ 2

IORTTEXTE

Dimensions: 9 rows × 4 columns

ORT ORTTEXT EREIGNIS_DTC FEHLERKLASSE
0x100001 Puffer für ausgehende Fehlermeldungen ist voll 1 -
0x100002 Fehler konnte nach maximaler Anzahl von Versuchen nicht gesendet werden 1 -
0x100003 SCR-Steuergerät-Reset. 0 -
0x8052D0 Aktivtank, Förderpumpe fördert Luft. 0 -
0x8052E0 Dosiermengenabweichung, dosierte Menge gemäß Druckstufen zu gering. 0 -
0x8052E1 Dosiermengenabweichung, dosierte Menge gemäß Druckstufen zu hoch. 0 -
0x80537B Motorabstellzeit, unplausibel bei Motorstart nach abgeschlossenem SCR-Nachlauf. 0 -
0x80537E Motorabstellzeit, unplausibel zu Motorabstellzeit der DDE. 0 -
0xFFFFFF unbekannter Fehlerort 0 -

IUMWELTTEXTE

Dimensions: 178 rows × 9 columns

UWNR UWTEXT UW_EINH L/H UWTYP NAME MUL DIV ADD
0x1750 F_UW_BN - High unsigned char - 1.0 1.0 0.0
0xD28D UWB_CAN_RX_MOTOR_AUS_ZEIT min High unsigned int - 1.0 1.0 0.0
0xD28E UWB_CAN_RX_STATUS_MOTOR_AUS_ZEIT 0-n High 0xFFFF TAB_CAN_RX_STATUS_MOTOR_AUS_ZEIT - - -
0xD28F UWB_CAN_RX_STATUS_FID_SCR_SYSTEM - High unsigned int - 1.0 1.0 0.0
0xD2B7 UWB_CAN_RX_SOLL_BEREITSTELLUNG_EINSPRITZMENGE_SCR_ADDITIV g High unsigned int - 0.001 1.0 0.0
0xD2B9 UWB_CAN_RX_STATUS_ABGAS_MASSENSTROM kg/h High unsigned int - 0.0625 1.0 0.0
0xD2BB UWB_CAN_RX_TEMPERATUR_AUSSEN °C High signed int - 0.0078125 1.0 0.0
0xD2BE UWB_CAN_RX_LUFTDRUCK_MOTOR_ANTRIEB hPa High unsigned int - 0.08291752 1.0 0.0
0xD2BF UWB_CAN_RX_TEMPERATUR_MOTOR_ANTRIEB °C High unsigned int - 1.0 1.0 -40.0
0xD2C4 UWB_CAN_RX_IST_DREHMOMENT_KURBELWELLE Nm High signed int - 0.03125 1.0 0.0
0xD2C5 UWB_CAN_RX_IST_DREHZAHL_MOTOR_KURBELWELLE 1/min High unsigned int - 1.0 1.0 0.0
0xD2C6 UWB_CAN_RX_STATUS_SPERRE_FEHLERSPEICHER_FZM 0-n High 0xFFFF STATUS_SPERRE_FEHLERSPEICHER_FZM - - -
0xD2C7 UWB_CAN_RX_GESCHWINDIGKEIT_FAHRZEUG_SCHWERPUNKT km/h High unsigned int - 1.0 1.0 0.0
0xD2CA UWB_CAN_RX_STATUS_KLEMME - High unsigned int - 1.0 1.0 0.0
0xD2CB UWB_CAN_RX_LAENGSBESCHLEUNIGUNG_SCHWERPUNKT m/s² High signed int - 0.0008475 1.0 0.0
0xD2CC UWB_CAN_RX_QUALIFIER_LAENGSBESCHLEUNIGUNG_SCHWERPUNKT - High unsigned int - 1.0 1.0 0.0
0xD2CD UWB_CAN_RX_QUERBESCHLEUNIGUNG_SCHWERPUNKT m/s² High signed int - 0.0008475 1.0 0.0
0xD2CE UWB_CAN_RX_QUALIFIER_QUERBESCHLEUNIGUNG_SCHWERPUNKT - High unsigned int - 1.0 1.0 0.0
0xD2D0 UWB_CAN_RX_TEMPERATUR_SCR_KATALYSATOR °C High unsigned int - 0.0625 1.0 -273.15
0xD2D2 UWB_CAN_RX_TEMPERATUR_KRAFTSTOFF °C High unsigned int - 1.0 1.0 -50.0
0xD2DF UWB_CAN_RX_RESTLAUFLEISTUNG_SCR_ADDITIV km High unsigned int - 1.0 1.0 0.0
0xD2E0 UWB_CAN_TX_ANFORDERUNG_MIL_DIAGNOSE_OBD_SCR 0-n High 0xFFFF ANFORDERUNG_MIL_DIAGNOSE_OBD_SCR - - -
0xD2E1 UWB_CAN_TX_STATUS_SYSTEM_FEHLER_OBD_SCR - High unsigned int - 1.0 1.0 0.0
0xD2E2 UWB_CAN_TX_STATUS_SPERRE_SYR_SYSTEM - High unsigned int - 1.0 1.0 0.0
0xD2E3 UWB_CAN_TX_IST_BEREITSTELLUNG_EINSPRITZMENGE_SCR_ADDITIV g High unsigned int - 0.001 1.0 0.0
0xD2E4 UWB_CAN_TX_LIM_BEREITSTELLUNG_EINSPRITZMENGE_SCR_ADDITIV mg/s High unsigned int - 0.0625 1.0 0.0
0xD2E5 UWB_CAN_TX_STATUS_BEREITSTELLUNG_SCR_ADDITIV - High unsigned int - 1.0 1.0 0.0
0xD2E9 UWB_CAN_TX_STATUS_RESTLAUFLEISTUNG_SCR_ADDITIV km High unsigned int - 1.0 1.0 0.0
0xD3F9 UWB_CAN_TX_STATUS_IST_QUALITAET_SCR_ADDITIV 0-n High 0xFFFF TAB_CAN_TX_STATUS_IST_QUALITAET_SCR_ADDITIV - - -
0xD3FB UWB_CAN_TX_IST_STROM_VERBRAUCHER_FEPM A High unsigned int - 1.0 1.0 0.0
0xD46B UWB_FOERDERPUMPE_FEHLER_HIGH_BYTE - High unsigned int - 1.0 1.0 0.0
0xD46C UWB_FOERDERPUMPE_FEHLER_LOW_BYTE - Low unsigned int - 1.0 1.0 0.0
0xD46D UWB_DWIS_ANFORDERUNG_CCM - High unsigned int - 1.0 1.0 0.0
0xD46E UWB_DWIS_ANFORDERUNG_GRUPPE - High unsigned int - 1.0 1.0 0.0
0xD48F UWB_AKTIVTANKHEIZUNG_PWM % High unsigned int - 0.00610352 1.0 0.0
0xD490 UWB_DOSIERLEITUNGSHEIZUNG_PWM % High unsigned int - 0.00610352 1.0 0.0
0xD491 UWB_AKTIVTANKHEIZUNG_AKTIV 0/1 High 0x0001 - - - -
0xD492 UWB_DOSIERLEITUNGSHEIZUNG_AKTIV 0/1 High 0x0001 - - - -
0xD493 UWB_AKTIVTANKHEIZUNG_STROM_ROHWERT V High unsigned int - 0.00015258 1.0 0.0
0xD494 UWB_DOSIERLEITUNGSHEIZUNG_STROM_ROHWERT V High unsigned int - 0.00015258 1.0 0.0
0xD495 UWB_AKTIVTANKHEIZUNG_STROM A High unsigned int - 0.00097656 1.0 0.0
0xD496 UWB_DOSIERLEITUNGSHEIZUNG_STROM A High unsigned int - 0.00097656 1.0 0.0
0xD497 UWB_AKTIVTANKHEIZUNG_LEISTUNG W High unsigned int - 0.1 1.0 0.0
0xD498 UWB_DOSIERLEITUNGSHEIZUNG_LEISTUNG W High unsigned int - 0.1 1.0 0.0
0xD49B UWB_FOERDERPUMPE_STROM A High unsigned int - 0.001 1.0 0.0
0xD49C UWB_FOERDERPUMPE_DREHZAHL 1/min High unsigned int - 1.0 1.0 0.0
0xD49D UWB_DRUCKREGELUNG_AKTIV 0/1 High 0x0001 - - - -
0xD49E UWB_DRUCKREGELUNG_GEPRUEFT 0/1 High 0x0001 - - - -
0xD49F UWB_DOSIERLEITUNG_FUELLUNGSGRAD_NACH_RUECKSAUGEN ml High unsigned int - 0.01 1.0 0.0
0xD4A0 UWB_TEMPERATUR_LEVELSENSOR_AKTIVTANK_ROHWERT °C High unsigned int - 0.0625 1.0 -273.15
0xD4A1 UWB_TEMPERATUR_AKTIVTANK °C High unsigned int - 0.0625 1.0 -273.15
0xD4A2 UWB_TEMPERATUR_DRUCKSENSOR_ROHWERT °C High unsigned int - 0.0625 1.0 -273.15
0xD4A3 UWB_FOERDERPUMPE_DREHZAHL_SOLLWERT 1/min High unsigned int - 1.0 1.0 0.0
0xD4A4 UWB_DRUCK_ROHWERT bar High signed int - 0.00097656 1.0 0.0
0xD4A5 UWB_DRUCK_GEFILTERT bar High signed int - 0.00097656 1.0 0.0
0xD4A6 UWB_DRUCK_NOMINAL bar High signed int - 0.00097656 1.0 0.0
0xD4A7 UWB_DRUCK_ABWEICHUNG_VON_NOMINAL bar High signed int - 0.00097656 1.0 0.0
0xD4A8 UWB_SCHALLGESCHWINDIGKEIT_ROHWERT m/s High unsigned int - 0.1 1.0 0.0
0xD4A9 UWB_QUALITAET_ROHWERT % High unsigned int - 0.01 1.0 -10.0
0xD4AA UWB_QUALITAET % High unsigned int - 0.01 1.0 -10.0
0xD4AB UWB_LEVELSENSOR_AKTIVTANK_FEHLER - High unsigned int - 1.0 1.0 0.0
0xD4AC UWB_LEVELSIGNAL_GUELTIG_AKTIVTANK_DIREKT_PIEZO 0/1 High 0x0001 - - - -
0xD4AD UWB_LEVELSIGNAL_GUELTIG_AKTIVTANK_KOMBI_PIEZO 0/1 High 0x0001 - - - -
0xD4AE UWB_FUELLSTAND_AKTIVTANK_DIREKT_PIEZO_ROHWERT mm High unsigned int - 0.01 1.0 0.0
0xD4AF UWB_FUELLSTAND_AKTIVTANK_KOMBI_PIEZO_ROHWERT mm High unsigned int - 0.01 1.0 0.0
0xD4B0 UWB_FUELLSTAND_AKTIVTANK_DIREKT_PIEZO mm High unsigned int - 0.01 1.0 0.0
0xD4B1 UWB_FUELLSTAND_AKTIVTANK_KOMBI_PIEZO mm High unsigned int - 0.01 1.0 0.0
0xD4B2 UWB_AMPLITUDE_ECHO_1_DIREKT_PIEZO - High unsigned int - 0.1 1.0 0.0
0xD4B3 UWB_AMPLITUDE_ECHO_1_KOMBI_PIEZO - High unsigned int - 0.1 1.0 0.0
0xD4B4 UWB_AMPLITUDE_ECHO_2_KOMBI_PIEZO - High unsigned int - 0.1 1.0 0.0
0xD4B5 UWB_AMPLITUDE_ECHO_3_KOMBI_PIEZO - High unsigned int - 0.1 1.0 0.0
0xD4B6 UWB_FUELLMENGE_AKTIVTANK_DIREKT_PIEZO_UNGEFILTERT l High unsigned int - 0.1 1.0 0.0
0xD4B7 UWB_FUELLMENGE_AKTIVTANK_KOMBI_PIEZO_UNGEFILTERT l High unsigned int - 0.1 1.0 0.0
0xD4C3 UWB_BATTERIESPANNUNG_SCR V High signed int - 0.01953125 1.0 0.0
0xD4D0 UWB_FUELLMENGE_AKTIVTANK_SCHNELL_GEFILTERT l High unsigned int - 0.00097656 1.0 0.0
0xD4D1 UWB_FUELLMENGE_AKTIVTANK_LANGSAM_GEFILTERT l High unsigned int - 0.00097656 1.0 0.0
0xD4D2 UWB_FUELLMENGE_AKTIVTANK_RELATIV % High unsigned int - 0.39215686 1.0 0.0
0xD4D3 UWB_NACHFUELLBARE_MENGE_AKTIVTANK_GEFILTERT l High unsigned int - 0.00097656 1.0 0.0
0xD4D4 UWB_FREIGABEMASKE_FUER_FUELLSTANDSFUNKTION_AKTIVTANK - High unsigned int - 1.0 1.0 0.0
0xD4D6 UWB_NACHTANKERKENNUNG 0/1 High 0x0001 - - - -
0xD4D7 UWB_AUFTAUZEIT_AKTUELL s High unsigned int - 0.1 1.0 0.0
0xD4D8 UWB_AUFTAUZEIT_VORGABE s High unsigned int - 0.1 1.0 0.0
0xD4D9 UWB_AUFTAUZEIT_EPA s High unsigned int - 0.1 1.0 0.0
0xD4DA UWB_AUFTAUEN_AKTIV 0/1 High 0x0001 - - - -
0xD4DB UWB_AUFTAUEN_ABGESCHLOSSEN 0/1 High 0x0001 - - - -
0xD4DC UBW_TEMPERATUR_AKTIVTANK_GESPEICHERT °C High unsigned int - 0.0625 1.0 -273.15
0xD4DE UWB_AKTIVTANK_GEFROREN 0/1 High 0x0001 - - - -
0xD4DF UWB_LEVELSENSOR_PASSIVTANK_ANZAHL_ECHOS - High unsigned int - 1.0 1.0 0.0
0xD4E1 UWB_TEMPERATUR_PASSIVTANK °C High unsigned int - 0.0625 1.0 -273.15
0xD4E4 UWB_FREIGABEMASKE_FUER_FUELLSTANDSFUNKTION_PASSIVTANK - High unsigned int - 1.0 1.0 0.0
0xD4E5 UWB_NACHFUELLBARE_MENGE_PASSIVTANK_GEFILTERT l High unsigned int - 0.00097656 1.0 0.0
0xD4E6 UWB_PASSIVTANK_VERBAUT 0/1 High 0x0001 - - - -
0xD4E7 UWB_LANGZEIT_UMPUMPMENGE l High unsigned int - 0.1 1.0 0.0
0xD4E8 UWB_TEMPERATUR_SCR_STEUERGERAET °C High unsigned int - 0.75 1.0 -48.0
0xD4E9 UWB_ZUSTAND_SCR_SYSTEM - High unsigned int - 1.0 1.0 0.0
0xD4EA UWB_NACHLAUF_GESTARTET 0/1 High 0x0001 - - - -
0xD4EC UWB_NACHLAUF_AKTIV 0/1 High 0x0001 - - - -
0xD4ED UWB_NACHLAUF_ABGESCHLOSSEN 0/1 High 0x0001 - - - -
0xD4EE UWB_NACHLAUFZEIT s High unsigned int - 0.1 1.0 0.0
0xD4EF UWB_ZEIT_SEIT_MOTORSTOPP min High unsigned int - 1.0 1.0 0.0
0xD4F0 UWB_ZEIT_SEIT_MOTORSTART s High unsigned int - 0.1 1.0 0.0
0xD4F1 UWB_TEMPERATUR_DOSIERVENTIL °C High unsigned int - 0.0625 1.0 -273.15
0xD4F2 UWB_WIDERSTAND_DOSIERVENTIL_GEMESSEN Ohm High unsigned int - 0.00195313 1.0 0.0
0xD4F3 UWB_WIDERSTAND_DOSIERVENTIL_OFFSET_ROHWERT Ohm High signed int - 0.00195313 1.0 0.0
0xD4F4 UWB_WIDERSTAND_DOSIERVENTIL_OFFSETWERT Ohm High signed int - 0.00195313 1.0 0.0
0xD4F5 UWB_STROM_DOSIERVENTIL A High unsigned int - 0.00097656 1.0 0.0
0xD4F6 UWB_TASTVERHAELTNIS_DOSIERVENTIL_ANFORDERUNG % High unsigned int - 0.00610352 1.0 0.0
0xD4F7 UWB_FREQUENZ_DOSIERVENTIL_ANFORDERUNG Hz High unsigned int - 0.015625 1.0 0.0
0xD4F9 UWB_MASSENSTROM_DOSIERVENTIL mg/s High unsigned int - 0.015625 1.0 0.0
0xD4FA UWB_LANGZEIT_DOSIERMENGE g High unsigned int - 32.768 1.0 0.0
0xD4FB UWB_DOSIERVENTIL_FEHLER - High unsigned int - 1.0 1.0 0.0
0xD4FE UWB_KILOMETER_AKTUELLER_DC km High unsigned int - 0.1 1.0 0.0
0xD4FF UWB_ZEITDAUER_UEBERTEMPERATUR_DOSIERVENTIL s High unsigned int - 1.0 1.0 0.0
0xD6E0 UWB_LAUFZEIT_ECHO_1_DIREKT_PIEZO µs High unsigned int - 0.015625 1.0 0.0
0xD6E1 UWB_LAUFZEIT_ECHO_1_KOMBI_PIEZO µs High unsigned int - 0.015625 1.0 0.0
0xD6E2 UWB_LAUFZEIT_ECHO_2_KOMBI_PIEZO µs High unsigned int - 0.015625 1.0 0.0
0xD6E3 UWB_LAUFZEIT_ECHO_3_KOMBI_PIEZO µs High unsigned int - 0.015625 1.0 0.0
0xD6E4 UWB_SIGNALGUETE_ECHO_1_DIREKT_PIEZO - High unsigned int - 1.0 1.0 0.0
0xD6E5 UWB_SIGNALGUETE_ECHO_1_KOMBI_PIEZO - High unsigned int - 1.0 1.0 0.0
0xD6E6 UWB_SIGNALGUETE_ECHO_2_KOMBI_PIEZO - High unsigned int - 1.0 1.0 0.0
0xD6E7 UWB_SIGNALGUETE_ECHO_3_KOMBI_PIEZO - High unsigned int - 1.0 1.0 0.0
0xD6E8 UWB_ZEIT_REHEATING s High unsigned int - 1.0 1.0 0.0
0xD6EA UWB_FUELLSTAND_PASSIVTANK_ROHWERT mm High unsigned int - 0.25 1.0 0.0
0xD6EB UWB_FUELLMENGE_PASSIVTANK_RELATIV % High unsigned int - 0.5 1.0 0.0
0xD6EC UWB_FUELLMENGE_PASSIVTANK_ROHWERT l High unsigned int - 0.1 1.0 0.0
0xD6ED UWB_FUELLMENGE_PASSIVTANK_SCHNELL_GEFILTERT l High unsigned int - 0.00097656 1.0 0.0
0xD6EF UWB_FUELLMENGE_PASSIVTANK_LANGSAM_GEFILTERT l High unsigned int - 0.00097656 1.0 0.0
0xD6F0 UWB_ERSTBEFUELLUNGSSTATUS 0/1 High 0x0001 - - - -
0xD6F2 UWB_LERNWERT_FOERDERPUMPE µl High unsigned int - 0.1 1.0 0.0
0xD6F3 UWB_TEMPERATUR_DOSIERVENTIL_MAXIMAL °C High unsigned int - 0.0625 1.0 -273.15
0xD6F7 UWB_PRODUKTIONSDATUM_LQS HEX High unsigned int - - - -
0xD6FB UWB_KAVITAETSERKENNUNG_GUELTIG 0/1 High 0x0001 - - - -
0xD7C1 UWB_CDM2_SUMME_NACHFUELLMENGE l High unsigned int - 0.00097656 1.0 0.0
0xD7C2 UWB_TEMPERATUR_FOERDERPUMPE °C High unsigned int - 0.0625 1.0 -273.15
0xD7C4 UWB_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_GEFILTERT µl High unsigned int - 0.1 1.0 0.0
0xD7C5 UWB_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_ERSTER µl High unsigned int - 0.1 1.0 0.0
0xD7C6 UWB_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_REFERENZ µl High unsigned int - 0.1 1.0 0.0
0xD7D4 UWB_DOSIERMENGE_AKTUELLER_DC mg High unsigned int - 16.0 1.0 0.0
0xD7D5 UWB_FOERDERPUMPE_PWM_SOLL % High unsigned int - 0.00610352 1.0 0.0
0xD7D6 UWB_FOERDERPUMPE_PWM_IST % High unsigned int - 0.00610352 1.0 0.0
0xD7D8 UWB_CDM2_VERBRAUCH_IST_ZU_SOLL % High signed int - 0.1 1.0 0.0
0xD7DA UWB_CDM2_FUELLMENGE_AKTIVTANK_ENDE l High unsigned int - 0.00097656 1.0 0.0
0xD7DB UWB_CDM2_FUELLMENGE_AKTIVTANK_ANFANG l High unsigned int - 0.00097656 1.0 0.0
0xD7DC UWB_TEMPERATUR_ABGAS_DOSIERVENTIL °C High signed int - 0.0625 1.0 0.0
0xD7DE UWB_TEMPERATUR_DRUCKSENSOR_CROSSCHECK °C High unsigned int - 0.0625 1.0 -273.15
0xD7DF UWB_TEMPERATUR_LEVELSENSOR_AKTIVTANK_CROSSCHECK °C High unsigned int - 0.0625 1.0 -273.15
0xD7EE UWB_TEMPERATUR_DOSIERVENTIL_CROSSCHECK °C High signed int - 0.0078125 1.0 0.0
0xD7EF UWB_SYSTEMLECKAGE_DIAGNOSE - High unsigned int - 0.03125 1.0 0.0
0xD810 UWB_SYSTEMLECKAGE_GEMESSEN - High unsigned int - 0.03125 1.0 0.0
0xD812 UWB_VOLUMENSTROM_ANGEFORDERT - High unsigned int - 1.0 1.0 0.0
0xD813 UWB_CDM1_VERBRAUCH_IST_ZU_SOLL % High signed int - 0.1 1.0 0.0
0xD814 UWB_DOSIERVENTIL_SPANNUNG_HIGH_SIDE V High unsigned int - 0.00015258 1.0 0.0
0xD815 UWB_DOSIERVENTIL_SPANNUNG_LOW_SIDE V High unsigned int - 0.00015258 1.0 0.0
0xD816 UWB_SPANNUNG_KLEMME_30B_LOGIK V High signed int - 0.01953125 1.0 0.0
0xD818 UWB_SPANNUNG_KLEMME_30_HEIZER V High signed int - 0.01953125 1.0 0.0
0xD826 UWB_DRUCKSENSOR_DATEN_FAST_CHANNEL - High unsigned int - 1.0 1.0 0.0
0xD827 UWB_DRUCKSENSOR_FEHLER - High unsigned int - 1.0 1.0 0.0
0xD828 UWB_LECKAGE_FUELLSTANDSBASIERT_BITFELD - High unsigned int - 1.0 1.0 0.0
0xD829 UWB_CDM3_DOSIERMENGENABWEICHUNG_RELATIV % High signed int - 0.1 1.0 0.0
0xD82A UWB_CDM3_DOSIERMENGE_IST_AUS_DRUCKSTUFEN mg High unsigned int - 1.0 1.0 0.0
0xD82B UWB_CDM3_DOSIERMENGE_SOLL mg High unsigned int - 1.0 1.0 0.0
0xD82D UWB_SUMME_DRUCKSTUFEN_INJ_BLOCK bar High signed int - 0.00097656 1.0 0.0
0xD82E UWB_SUMME_DRUCKSTUFEN_PUMP_AIR bar High signed int - 0.00097656 1.0 0.0
0xD84E UWB_CDM2_HIGH_RELATIV % High signed int - 0.01 1.0 0.0
0xD84F UWB_CDM2_LOW_RELATIV % High signed int - 0.01 1.0 0.0
0xD854 UWB_LECKAGE_REFERENZ_DOSIERMENGE_INJEKTOR l High unsigned int - 0.00048828 1.0 0.0
0xD855 UWB_CDM2_DOSIERMENGE_AUS_FUELLSTANDSAENDERUNG l High signed int - 0.00097656 1.0 0.0
0xD856 UWB_LECKAGE_DOSIERMENGE_AUS_FUELLSTANDSAENDERUNG l High unsigned int - 0.00048828 1.0 0.0
0xD857 UWB_CDM2_REFERENZ_DOSIERMENGE_INJEKTOR l High unsigned int - 0.00097656 1.0 0.0
0xD858 UWB_CDM2_VOLUMEN_AUS_FUELLSTANDSAENDERUNG l High signed int - 0.00097656 1.0 0.0
0xD8F6 UWB_SYSTEMSTEIFIGKEIT_BERECHNET - High unsigned int - 0.00012207 1.0 0.0
0xD8F7 UWB_SYSTEM_LECKAGE_ADAPTIERT - High unsigned int - 0.03125 1.0 0.0
0xD8F8 UWB_SYSTEM_LECKAGE_CDM1 - High unsigned int - 0.03125 1.0 0.0
0xD8F9 UWB_CDM1_VOLUMEN_AUS_DOSIERANFORDERUNG l High unsigned int - 0.00097656 1.0 0.0
0xD8FA UWB_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_GEFILTERT_2 µl High unsigned int - 0.1 1.0 0.0
0xD8FB UWB_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_ERSTER_2 µl High unsigned int - 0.1 1.0 0.0
0xD8FC UWB_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_REFERENZ_2 µl High unsigned int - 0.1 1.0 0.0
0xXYXY unbekannte Umweltbedingung - - - - - - -

JOBRESULTEXTENDED

Dimensions: 1 rows × 2 columns

SB STATUS_TEXT
0xXY ERROR_UNKNOWN

MESSAUFZEICHNUNG

Dimensions: 9 rows × 2 columns

WERT TEXT
0x0000 Messung ungültig
0x1000 Konzentrationsmessung vorhanden
0x2000 TD1 Füllstandsmessung vorhanden
0x3000 TD1 Füllstandsmessung und Konzentration vorhanden
0x4000 Messung unplausibel
0x5000 Messung unplausibel und Konzentration vorhanden
0x6000 -
0x7000 Messung nicht durchgeführt
0xFFFF Wert ungültig

MESSUNGEN

Dimensions: 7 rows × 2 columns

WERT TEXT
0x00 0/5 plausible Messungen
0x01 1/5 plausible Messungen
0x02 2/5 plausible Messungen
0x03 3/5 plausible Messungen
0x04 4/5 plausible Messungen
0x05 5/5 plausible Messungen
0xFF Wert ungültig

NTC_ERROR

Dimensions: 4 rows × 2 columns

WERT TEXT
0x0000 kein Fehler
0x0004 offene Leitung
0x0008 Kurzschluss
0xFFFF Wert ungültig

PASSIVTANK_VERBAUT

Dimensions: 3 rows × 2 columns

WERT TEXT
0x00 Kein Passivtank verbaut.
0x01 Passivtank verbaut.
0xFF Wert ungültig

QUALIFIER_GESCHWINDIGKEIT_FAHRZEUG_SCHWERPUNKT

Dimensions: 14 rows × 2 columns

WERT TEXT
0x8 Initialisierung
0x1 Signalwert ist gültig und abgesichert und plausibilisiert
0x9 reserviert
0x2 reserviert
0xA Signalwert ist gültig, Zustand/Status temporär
0x3 reserviert
0xB Signalqualität bzw. Überwachung eingeschränkt, Zustand/Status temporär
0x4 reserviert
0xC reserviert
0x6 reserviert
0xE Signalwert ist ungültig, Zustand/Status temporär
0x7 reserviert
0xF Signal ungültig
0xFF Wert ungültig

QUALIFIER_IST_DREHZAHL_MOTOR_KURBELWELLE

Dimensions: 14 rows × 2 columns

WERT TEXT
0x8 Initialisierung
0x1 Signalwert ist gültig und abgesichert und plausibilisiert
0x9 reserviert
0x2 Signalwert ist gültig, Zustand/Status permanent
0xA reserviert
0x3 reserviert
0xB reserviert
0x4 Ersatzwert ist im Nutzsignal gesetzt, Zustand/Status permanent
0xC Abgleichwert ist im Nutzsignal gesetzt, Zustand/Status temporär
0x6 Signalwert ist ungültig
0xE reserviert
0x7 reserviert
0xF Signal ungültig
0xFF Wert ungültig

QUALIFIER_LAENGSBESCHLEUNIGUNG_SCHWERPUNKT

Dimensions: 14 rows × 2 columns

WERT TEXT
0x8 Initialisierung
0x1 reserviert
0x9 reserviert
0x2 Signalwert ist gültig
0xA Signalwert ist gültig, Zustand/Status temporär
0x3 Signalqualität bzw. Überwachung eingeschränkt
0xB Signalqualität bzw. Überwachung eingeschränkt, Zustand/Status temporär
0x4 reserviert
0xC Ersatzwert ist im Nutzsignal gesetzt, Zustand/Status temporär
0x6 Signalwert ist ungültig
0xE Signalwert ist ungültig, Zustand/Status temporär
0x7 reserviert
0xF Signal ungültig
0xFF Wert ungültig

QUALIFIER_QUERBESCHLEUNIGUNG_SCHWERPUNKT

Dimensions: 14 rows × 2 columns

WERT TEXT
0x8 Initialisierung
0x1 reserviert
0x9 reserviert
0x2 Signalwert ist gültig
0xA Signalwert ist gültig, Zustand/Status temporär
0x3 Signalqualität bzw. Überwachung eingeschränkt
0xB Signalqualität bzw. Überwachung eingeschränkt, Zustand/Status temporär
0x4 reserviert
0xC Ersatzwert ist im Nutzsignal gesetzt, Zustand/Status temporär
0x6 Signalwert ist ungültig
0xE Signalwert ist ungültig, Zustand/Status temporär
0x7 reserviert
0xF Signal ungültig
0xFF Wert ungültig

RBM_CYCLE

Dimensions: 4 rows × 2 columns

WERT TEXT
0x00 RBM Zyklus nicht aktiv
0x04 RBM Zyklus aktiv
0x24 RBM Zyklus nicht erfüllbar
0xFF Wert ungültig

RDBI_ADS_DOP

Dimensions: 10 rows × 2 columns

WERT TEXT
0x00 ISOSAEReserved_00
0x01 defaultSession
0x02 programmingSession
0x03 extendedDiagnosticSession
0x04 safetySystemDiagnosticSession
0x40 vehicleManufacturerSpecific_40
0x41 codingSession
0x42 SWTSession
0x43 HDDUpdateSession
0xff ungültig

RDBI_PC_PCS_DOP

Dimensions: 4 rows × 2 columns

WERT TEXT
0x00 ECU mehrmals programmierbar
0x01 ECU mindestens einmal vollstaendig programmierbar
0x02 ECU nicht mehr programmierbar
0xff ungültig

RES_0X1061_R

Dimensions: 1 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_FS_ENDE_WABL - - + 0/1 high unsigned char - - - - - 0: Verriegelt (loeschen von Einzelfehlern und PDTCs wird unterbunden) 1: Entriegelt (loeschen von Einzelfehlern und PDTCs wird nicht unterbunden)

RES_0X2502_D

Dimensions: 3 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_RESERVE_WERT - high unsigned char - - 1.0 1.0 0.0 Reserve. Konstante = 0x00
STAT_PROG_ZAEHLER_STATUS 0-n high unsigned char - RDBI_PC_PCS_DOP - - - ProgrammingCounterStatus
STAT_PROG_ZAEHLER_WERT - high unsigned int - - 1.0 1.0 0.0 ProgrammingCounter

RES_0X2504_D

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ERASE_MEMORY_TIME_WERT s high unsigned int - - 1.0 1.0 0.0 EraseMemoryTime, maximale SWE-Löschzeit mit Ablaufkontrolle im Steuergerät.
STAT_CHECK_MEMORY_TIME_WERT s high unsigned int - - 1.0 1.0 0.0 CheckMemoryTime (Bsp.: Signaturprüfung), maximale Speicherprüfzeit mit Ablaufkontrolle im Steuergerät.
STAT_BOOTLOADER_INSTALLATION_TIME_WERT s high unsigned int - - 1.0 1.0 0.0 BootloaderInstallationTime Die Zeit, die nach dem Reset benötigt wird, damit der Hilfsbootloader gestartet wird, den Bootloader löscht, den neuen Bootloader kopiert, dessen Signatur prüf und der neue Bootloader gestartet wird bis er wieder diagnosefähig ist. Angabe ist verpflichtend für alle Steuergeräte, auch wenn das Steuergerät keinen Bootloader Update geplant hat. Ein Wert von 0x0000 ist verboten.
STAT_AUTHENTICATION_TIME_WERT s high unsigned int - - 1.0 1.0 0.0 AuthenticationTime, die maximale Zeit, die das Steuergerät zur Prüfung der Authentisierung (sendKey) benötigt mit Ablaufkontrolle im Steuergerät.
STAT_RESET_TIME_WERT s high unsigned int - - 1.0 1.0 0.0 ResetTime Die Zeitangabe bezieht sich auf den Übergang von der ApplicationExtendedSesssion in die ProgrammingSession bzw. bei Übergang von der ProgrammingSession in die DefaultSession. Es ist der Maximalwert auszugeben. Nach Ablauf der ResetTime ist das Steuergerät durch Diagnose ansprechbar.
STAT_TRANSFER_DATA_TIME_WERT s high unsigned int - - 1.0 1.0 0.0 TransferDataTime Die Angabe hat sich zu beziehen auf einen TransferData mit maximaler Blocklänge auf die Zeitspanne vom vollständigen Empfang der Daten im Steuergerät über das ggf. erforderliche Dekomprimieren und dem vollständigen Speichern im nichtflüchtigen Speicher bis einschließlich dem Senden der positiven Response.

RES_0X4006_R

Dimensions: 1 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_RAM_DATEN_SCHREIBEN - - + 0-n high unsigned char - STATUS_RAM_DATEN_SCHREIBEN_TAB - - - Status RAM_DATEN_SCHREIBEN

RES_0XAE60_R

Dimensions: 3 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ZUSTAND_ROUTINE - - + 0-n high unsigned char - TAB_STATE_ROUTINE - - - Zustand der Routine.
- - - + Bit high BITFIELD - BF_FREIGABE_ROUTINE - - - Status der Start- und Freigabebedingungen für die Routine.
STAT_KOMPLETTRUECKSAUGEN_DETAIL - - + 0-n high unsigned char - TAB_RUECKSAUGEN_DETAIL - - - Detaillierter Status der Routine Komplettrücksaugen.

RES_0XAE61_R

Dimensions: 3 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ZUSTAND_ROUTINE - - + 0-n high unsigned char - TAB_STATE_ROUTINE - - - Zustand der Routine.
- - - + Bit high BITFIELD - BF_FREIGABE_ROUTINE - - - Status der Start- und Freigabebedingungen für die Routine.
STAT_TEILRUECKSAUGEN_DETAIL - - + 0-n high unsigned char - TAB_RUECKSAUGEN_DETAIL - - - Detaillierter Status der Routine Teilrücksaugen.

RES_0XAE62_R

Dimensions: 3 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ZUSTAND_ROUTINE - - + 0-n high unsigned char - TAB_STATE_ROUTINE - - - Zustand der Routine.
- - - + Bit high BITFIELD - BF_FREIGABE_ROUTINE - - - Status der Start- und Freigabebedingungen für die Routine.
STAT_LECKAGEERKENNUNG_DETAIL - - + 0-n high unsigned char - TAB_LECKAGEERKENNUNG_DETAIL - - - Detaillierter Status der Routine Leckageerkennung.

RES_0XAE63_R

Dimensions: 3 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ZUSTAND_ROUTINE - - + 0-n high unsigned char - TAB_STATE_ROUTINE - - - Zustand der Routine.
- - - + Bit high BITFIELD - BF_FREIGABE_ROUTINE - - - Status der Start- und Freigabebedingungen für die Routine.
STAT_DRUCKAUFBAU_DETAIL - - + 0-n high unsigned char - TAB_DRUCKAUFBAU_DETAIL - - - Detaillierter Status der Routine Druckaufbau.

RES_0XAE64_R

Dimensions: 3 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ZUSTAND_ROUTINE - - + 0-n high unsigned char - TAB_STATE_ROUTINE - - - Zustand der Routine.
- - - + Bit high BITFIELD - BF_FREIGABE_ROUTINE - - - Status der Start- und Freigabebedingungen für die Routine.
STAT_DOSIERMENGENTEST_DETAIL - - + 0-n high unsigned char - TAB_DOSIERMENGENTEST_DETAIL - - - Detaillierter Status für die Routine Dosiermengentest.

RES_0XAE68_R

Dimensions: 4 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ZUSTAND_ROUTINE - - + 0-n high unsigned char - TAB_STATE_ROUTINE - - - Zustand der Routine.
- - - + Bit high BITFIELD - BF_FREIGABE_ROUTINE - - - Status der Start- und Freigabebedingungen für die Routine.
- - - + Bit high BITFIELD - BF_ACT_INIT_TESTS - - - Aktuell laufender Teilschritt.
- - - + Bit high BITFIELD - BF_SCR_INIT - - - Status Inbetriebnahmesquenz.

RES_0XAE6A_R

Dimensions: 3 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ZUSTAND_ROUTINE - - + 0-n high unsigned char - TAB_STATE_ROUTINE - - - Zustand der Routine.
- - - + Bit high BITFIELD - BF_FREIGABE_ROUTINE - - - Status der Start- und Freigabebedingungen für die Routine.
STAT_TROCKENTAKTUNG_DETAIL - - + 0-n high unsigned char - TAB_TROCKENTAKTUNG_DETAIL - - - Detaillierter Status der Routine Trockentaktung.

RES_0XAE6B_R

Dimensions: 3 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ZUSTAND_ROUTINE - - + 0-n high unsigned char - TAB_STATE_ROUTINE - - - Zustand der Routine.
- - - + Bit high BITFIELD - BF_FREIGABE_ROUTINE - - - Status der Start- und Freigabebedingungen für die Routine.
STAT_TRANSFERPUMPE_DETAIL - - + 0-n high unsigned char - TAB_TRANSFERPUMPE_DETAIL - - - Detaillierter Status der Routine Test Transferpumpe.

RES_0XAE6C_R

Dimensions: 3 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ZUSTAND_ROUTINE - - + 0-n high unsigned char - TAB_STATE_ROUTINE - - - Zustand der Routine
- - - + Bit high BITFIELD - BF_FREIGABE_ROUTINE - - - Status der Start- und Freigabebedingungen für die Routine.
STAT_AKTIVTANKHEIZUNG_DETAIL - - + 0-n high unsigned char - TAB_HEIZUNG_DETAIL - - - Deatillierter Status der Routine Test Aktivtankheizung.

RES_0XAE6D_R

Dimensions: 3 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ZUSTAND_ROUTINE - - + 0-n high unsigned char - TAB_STATE_ROUTINE - - - Zustand der Routine.
- - - + Bit high BITFIELD - BF_FREIGABE_ROUTINE - - - Status der Start- und Freigabebedingungen für die Routine.
STAT_DOSIERLEITUNGSHEIZUNG_DETAIL - - + 0-n high unsigned char - TAB_HEIZUNG_DETAIL - - - Detaillierter Zustand der Routine Test Dosierleitungsheizung.

RES_0XAE6E_R

Dimensions: 2 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ZUSTAND_ROUTINE - - + 0-n high unsigned char - TAB_STATE_ROUTINE - - - Zustand der Routine.
STAT_SCR_DEAKTIVIERUNG_SCHUTZDOSIERUNG - - + 0-n high unsigned char - TAB_STATE_DEAKTIVIERUNG_SCHUTZDOSIERUNG - - - Status der Deaktivierung der Schutzdosierung.

RES_0XAE6F_R

Dimensions: 2 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ZUSTAND_ROUTINE - - + 0-n high unsigned char - TAB_STATE_ROUTINE - - - Zustand der Routine.
STAT_SCR_MONTAGEMODUS - - + 0-n high unsigned char - TAB_STATE_MONTAGEMODUS - - - Zustand des Montagemodus. 0 = Montagemodus inaktiv. 1 = Montagemodus aktiv.

SCR_SYSTEM_ZUSTAND

Dimensions: 8 rows × 2 columns

WERT TEXT
0x0000 ES_ON - Zündung an, Motor aus
0x0001 ASYN_ON - Zündung an und asynchrone Kurbelwellenrotation
0x0002 SYN_ON - Zündung an und synchrone Kurbelwellenrotation
0x0003 SYN_OFF - Zündung aus und synchrone Kurbelwellenrotation
0x0004 PWL - Nachlauf
0x0005 WAIT - Vorlauf
0x0006 DEAC - SG geht in den Ruhezustand
0xFFFF Wert ungültig

SG_FUNKTIONEN

Dimensions: 274 rows × 16 columns

ARG ID RESULTNAME INFO EINHEIT LABEL L/H DATENTYP NAME MUL DIV ADD SG_ADR SERVICE ARG_TABELLE RES_TABELLE
FS_LOESCHEN_PERMANENT 0x1060 - Job zum Löschen der Permanent-DTCs - - - - - - - - - 31 - -
FEHLERSPEICHER_ENDE_WERKSABLAUF 0x1061 - Löschen von Einzelfehlern und Permanent-DTCs unterbindet - - - - - - - - - 31 - RES_0x1061_R
PROGRAMMING_COUNTER 0x2502 - Programming-Counter - - - - - - - - - 22 - RES_0x2502_D
PROGRAMMING_COUNTER_MAX_VALUE 0x2503 STAT_PROG_MAX_WERT maximalen Anzahl von Programmiervorgängen - - High unsigned int - 1.0 1.0 0.0 - 22 - -
FLASH_TIMING_PARAMETER 0x2504 - Programmierspezifische Timing Parameter - - - - - - - - - 22 - RES_0x2504_D
MILE_KM_EEPROM 0x2540 STAT_MILE_KM_EEPROM_DATA Im EEPROM abgelegter Kilometerstand. DATA - High data[3] - 1.0 1.0 0.0 - 22 - -
RAM_DATEN_SCHREIBEN 0x4006 - Dient dazu während der Inbetriebnahme angelernte applikative Daten in den nichtflüchtigen Speicher zu sichern. - - - - - - - - - 31 - RES_0x4006_R
SCR_KOMPLETTRUECKSAUGEN 0xAE60 - Komplettrücksaugen - - - - - - - - - 31 - RES_0xAE60_R
SCR_TEILRUECKSAUGEN 0xAE61 - Teilrücksaugen - - - - - - - - - 31 - RES_0xAE61_R
SCR_LECKAGEERKENNUNG 0xAE62 - Leckageerkennung - - - - - - - - - 31 - RES_0xAE62_R
SCR_DRUCKAUFBAU 0xAE63 - Druckaufbau - - - - - - - - - 31 - RES_0xAE63_R
SCR_TEST_DOSIERMENGE 0xAE64 - Dosiermengentest - - - - - - - - - 31 ARG_0xAE64_R RES_0xAE64_R
SCR_SYSTEMCHECK_INIT 0xAE68 - Inbetriebnahmeroutine im Werk - - - - - - - - - 31 ARG_0xAE68_R RES_0xAE68_R
SCR_TROCKENTAKTUNG 0xAE6A - Funktionstest Dosierventil. - - - - - - - - - 31 - RES_0xAE6A_R
SCR_TRANSFERPUMPE 0xAE6B - Funktionstest Transferpumpe. - - - - - - - - - 31 ARG_0xAE6B_R RES_0xAE6B_R
SCR_TEST_AKTIVTANKHEIZUNG 0xAE6C - Funktionstest Aktivtankheizung - - - - - - - - - 31 - RES_0xAE6C_R
SCR_TEST_DOSIERLEITUNGSHEIZUNG 0xAE6D - Funktionstest Dosierleitungsheizung - - - - - - - - - 31 - RES_0xAE6D_R
SCR_DEAKTIVIERUNG_SCHUTZDOSIERUNG 0xAE6E - Manuelles Deaktivieren der AdBlue-Schutzdosierung für den Werkstattdiagnosetest der SCR-Abgaskomponenten. - - - - - - - - - 31 - RES_0xAE6E_R
MONTAGEMODUS 0xAE6F - Steuern des Montagemodus für das SCR Gen3 SG. - - - - - - - - - 31 - RES_0xAE6F_R
STEUERN_FOERDERPUMPE 0xD280 - Test zum Steuern der Förderpumpe. - - - - - - - - - 2F ARG_0xD280_D -
STEUERN_RUECKFOERDERPUMPE 0xD281 - Test zum Steuern der Förderpumpe (Rückwärtslauf). - - - - - - - - - 2F ARG_0xD281_D -
STEUERN_AKTIVTANKHEIZUNG 0xD282 - Test zum Steuern der Aktivtankheizung. - - - - - - - - - 2F ARG_0xD282_D -
STEUERN_DOSIERLEITUNGSHEIZUNG 0xD283 - Test zum Steuern der Dosierleitungsheizung. - - - - - - - - - 2F ARG_0xD283_D -
STEUERN_DOSIERVENTIL 0xD284 - Test zum Steuern des Dosierventils. - - - - - - - - - 2F ARG_0xD284_D -
STEUERN_TRANSFERPUMPE 0xD285 - Test zum Steuern der Transferpumpe. - - - - - - - - - 2F ARG_0xD285_D -
STEUERN_LANGZEIT_DOSIERMENGE 0xD286 - Schreiben der Langzeitdosiermenge. - - - - - - - - - 2E ARG_0xD286_D -
STEUERN_LANGZEIT_UMPUMPMENGE 0xD287 - Schreiben der Langzeitumpumpmenge. - - - - - - - - - 2E ARG_0xD287_D -
CAN_RX_MOTORABSTELLZEIT 0xD28D STAT_CAN_RX_MOTOR_AUS_ZEIT_WERT T_ES_CAN min T_ES_CAN High unsigned int - 1.0 1.0 0.0 - 22 - -
CAN_RX_STATUS_MOTOR_AUS_ZEIT 0xD28E STAT_CAN_RX_STATUS_MOTOR_AUS_ZEIT STATE_T_ES_CAN 0-n STATE_T_ES_CAN High unsigned int TAB_CAN_RX_STATUS_MOTOR_AUS_ZEIT - - - - 22 - -
CAN_RX_STATUS_FID_SCR_SYSTEM 0xD28F STAT_CAN_RX_STATUS_FID_SCR_SYSTEM_WERT LF_FID_INH_CUS_COM_RX_TMP - LF_FID_INH_CUS_COM_RX_TMP High unsigned int - 1.0 1.0 0.0 - 22 - -
STEUERN_ERSTBEFUELLUNGSSTATUS 0xD290 - Schreiben des Erstbefüllungsstatus. - - - - - - - - - 2E ARG_0xD290_D -
STEUERN_ZEITDAUER_SPULENHEIZEN 0xD291 - Schreiben der Zeitdauer für das Spulenheizen des Dosierventils. - - - - - - - - - 2E ARG_0xD291_D -
STEUERN_ZEITDAUER_UEBERTEMPERATUR_DOSIERVENTIL 0xD292 - Manuelles Rücksetzen der Zeitdauer für die Übertemperatur des Dosierventils. - - - - - - - - - 2E ARG_0xD292_D -
STEUERN_INITIALISIERUNG_LERNWERT_FOERDERPUMPE 0xD293 - Manuelles Neuinitialisieren des Lernwerts der Förderpumpe. - - - - - - - - - 2E ARG_0xD293_D -
STEUERN_INITIALISIERUNG_LERNWERT_DOSIERVENTIL 0xD294 - Manuelles Neuinitialisieren des Spulenwiderstands des Dosierventils. - - - - - - - - - 2E ARG_0xD294_D -
STEUERN_INITIALISIERUNG_FUELLMENGE_AKTIVTANK 0xD29A - Manuelles Neuinitialisieren der Füllmenge des Aktivtanks. - - - - - - - - - 2E ARG_0xD29A_D -
STEUERN_INITIALISIERUNG_FUELLMENGE_PASSIVTANK 0xD29B - Manuelles Neuinitialisieren der Füllmenge des Passivtanks. - - - - - - - - - 2E ARG_0xD29B_D -
STEUERN_INITIALISIERUNG_RAM 0xD29C - Neuinitialisierung zahlreicher nicht OBD-relevanter Systemgrößen. - - - - - - - - - 2E ARG_0xD29C_D -
CAN_RX_SOLL_BEREITSTELLUNG_EINSPRITZMENGE_SCR_ADDITIV 0xD2B7 STAT_CAN_RX_SOLL_BEREITSTELLUNG_EINSPRITZMENGE_SCR_ADDITIV_WERT MASS_RAG_TAR_INJ_DOWN g MASS_RAG_TAR_INJ_DOWN High unsigned int - 0.001 1.0 0.0 - 22 - -
CAN_RX_STATUS_ABGAS_MASSENSTROM 0xD2B9 STAT_CAN_RX_STATUS_ABGAS_MASSENSTROM_WERT MFL_EG_KGH kg/h MFL_EG_KGH High unsigned int - 0.0625 1.0 0.0 - 22 - -
CAN_RX_STATUS_INITIALISIERUNG_FILTER_WERT_DME 0xD2BA STAT_CAN_RX_STATUS_INITIALISIERUNG_FILTER_WERT_DME LV_M_RAG_REQ_SYN_SCRM 0-n LV_M_RAG_REQ_SYN_SCRM High unsigned char STATUS_INITIALISIERUNG_FILTER_WERT_DME - - - - 22 - -
CAN_RX_TEMPERATUR_AUSSEN 0xD2BB STAT_CAN_RX_TEMPERATUR_AUSSEN_WERT TAA °C TAA High signed int - 0.0078125 1.0 0.0 - 22 - -
CAN_RX_LUFTDRUCK_MOTOR_ANTRIEB 0xD2BE STAT_CAN_RX_LUFTDRUCK_MOTOR_ANTRIEB_WERT AMP hPa AMP High unsigned int - 0.08291752 1.0 0.0 - 22 - -
CAN_RX_TEMPERATUR_MOTOR_ANTRIEB 0xD2BF STAT_CAN_RX_TEMPERATUR_MOTOR_ANTRIEB_WERT TCO_1_SYS °C TCO_1_SYS High unsigned int - 1.0 1.0 -40.0 - 22 - -
CAN_RX_STATUS_ANTRIEB_FAHRZEUG 0xD2C0 - STATE_DRIV_VEH Bit ST_DRV_VEH High BITFIELD BF_STATUS_ANTRIEB_FAHRZEUG - - - - 22 - -
CAN_RX_STATUS_OBD_ZYKLUS 0xD2C1 - STATE_OBD_CYC_TMP Bit ST_OBD_CYC High BITFIELD BF_STATUS_OBD_ZYKLUS - - - - 22 - -
CAN_RX_OBD_POSITION_DROSSELKLAPPE_MOTOR 0xD2C2 STAT_CAN_RX_OBD_POSITION_DROSSELKLAPPE_MOTOR_WERT FAC_TPS_1_SAE % FAC_TPS_1_SAE High unsigned char - 0.3921568 1.0 0.0 - 22 - -
CAN_RX_OBD_MODELLWERT_LAST_MOTOR 0xD2C3 STAT_CAN_RX_OBD_MODELLWERT_LAST_MOTOR_WERT LOAD_CLC_SAE_CAN % LOAD_CLC_SAE_CAN High unsigned char - 0.3921568 1.0 0.0 - 22 - -
CAN_RX_IST_DREHMOMENT_KURBELWELLE 0xD2C4 STAT_CAN_RX_IST_DREHMOMENT_KURBELWELLE_WERT TQI_SP Nm TQI_SP High signed int - 0.03125 1.0 0.0 - 22 - -
CAN_RX_IST_DREHZAHL_MOTOR_KURBELWELLE 0xD2C5 STAT_CAN_RX_IST_DREHZAHL_MOTOR_KURBELWELLE_WERT N 1/min N High unsigned int - 1.0 1.0 0.0 - 22 - -
CAN_RX_STATUS_SPERRE_FEHLERSPEICHER_FZM 0xD2C6 STAT_CAN_RX_STATUS_SPERRE_FEHLERSPEICHER_FZM LV_CDN_COM_DIAG 0-n LV_CDN_COM_DIAG High unsigned int STATUS_SPERRE_FEHLERSPEICHER_FZM - - - - 22 - -
CAN_RX_GESCHWINDIGKEIT_FAHRZEUG_SCHWERPUNKT 0xD2C7 STAT_CAN_RX_GESCHWINDIGKEIT_FAHRZEUG_SCHWERPUNKT_WERT VS km/h VS High unsigned int - 1.0 1.0 0.0 - 22 - -
CAN_RX_WEGSTRECKE_KILOMETER 0xD2C8 STAT_CAN_RX_WEGSTRECKE_KILOMETER_WERT DIST_KM km DIST_KM High unsigned long - 1.0 1.0 0.0 - 22 - -
CAN_RX_STATUS_KLEMME 0xD2CA STAT_CAN_RX_STATUS_KLEMME STATE_IGK_CAN 0-n STATE_IGK_CAN High unsigned int STATUS_KLEMME - - - - 22 - -
CAN_RX_LAENGSBESCHLEUNIGUNG_SCHWERPUNKT 0xD2CB STAT_CAN_RX_LAENGSBESCHLEUNIGUNG_SCHWERPUNKT_WERT AC_VEH m/s² AC_VEH High signed int - 0.0008475 1.0 0.0 - 22 - -
CAN_RX_QUALIFIER_LAENGSBESCHLEUNIGUNG_SCHWERPUNKT 0xD2CC STAT_CAN_RX_QUALIFIER_LAENGSBESCHLEUNIGUNG_SCHWERPUNKT STATE_AC_LGT_VEH 0-n QU_ACLNX_COG High unsigned int QUALIFIER_LAENGSBESCHLEUNIGUNG_SCHWERPUNKT - - - - 22 - -
CAN_RX_QUERBESCHLEUNIGUNG_SCHWERPUNKT 0xD2CD STAT_CAN_RX_QUERBESCHLEUNIGUNG_SCHWERPUNKT_WERT AC_TRV_VEH m/s² AC_TRV_VEH High signed int - 0.0008475 1.0 0.0 - 22 - -
CAN_RX_QUALIFIER_QUERBESCHLEUNIGUNG_SCHWERPUNKT 0xD2CE STAT_CAN_RX_QUALIFIER_QUERBESCHLEUNIGUNG_SCHWERPUNKT STATE_AC_TRV_VEH 0-n QU_ACLNY_COG High unsigned int QUALIFIER_QUERBESCHLEUNIGUNG_SCHWERPUNKT - - - - 22 - -
CAN_RX_ZEIT_SEKUNDE_ZAEHLER_RELATIV 0xD2CF STAT_CAN_RX_ZEIT_SEKUNDE_ZAEHLER_RELATIV_WERT T_ABSV_COM s T_ABSV_COM High unsigned long - 1.0 1.0 0.0 - 22 - -
CAN_RX_TEMPERATUR_SCR_KATALYSATOR 0xD2D0 STAT_CAN_RX_TEMPERATUR_SCR_KATALYSATOR_WERT TEG_CAT_UP °C TEG_CAT_UP High unsigned int - 0.0625 1.0 -273.15 - 22 - -
CAN_RX_TEMPERATUR_KRAFTSTOFF 0xD2D2 STAT_CAN_RX_TEMPERATUR_KRAFTSTOFF_WERT TFU °C TFU High unsigned int - 1.0 1.0 -50.0 - 22 - -
CAN_RX_DREHMOMENT_FAHRERWUNSCH_PID_SCR_SYSTEM 0xD2D3 STAT_CAN_RX_DREHMOMENT_FAHRERWUNSCH_PID_SCR_SYSTEM_WERT TQ_REQ_CAN_SAE % TQ_REQ_CAN_SAE High unsigned char - 1.0 1.0 -125.0 - 22 - -
CAN_RX_DREHMOMENT_AKTUELLE_PID_SCR_SYSTEM 0xD2D4 STAT_CAN_RX_DREHMOMENT_AKTUELLE_PID_SCR_SYSTEM_WERT TQI_AV_SAE % TQI_AV_SAE High unsigned char - 1.0 1.0 -125.0 - 22 - -
CAN_RX_STATUS_ZUSTAND_FAHRZEUG 0xD2D5 STAT_CAN_RX_STATUS_ZUSTAND_FAHRZEUG STATE_PTL_NET 0-n ST_CON_VEH High unsigned char STATUS_ZUSTAND_FAHRZEUG - - - - 22 - -
CAN_RX_EINSPRITZMENGE_KRAFTSTOFF_MOTOR 0xD2D6 STAT_CAN_RX_EINSPRITZMENGE_KRAFTSTOFF_MOTOR_WERT FCO_SUM_CAN_H_RNG µl FCO_SUM_CAN_H_RNG High unsigned int - 1.0 1.0 0.0 - 22 - -
CAN_RX_QUALIFIER_IST_DREHZAHL_MOTOR_KURBELWELLE 0xD2DA STAT_CAN_RX_QUALIFIER_IST_DREHZAHL_MOTOR_KURBELWELLE STATE_N_CAN 0-n QU_AVL_RPM_ENG_CRSH High unsigned char QUALIFIER_IST_DREHZAHL_MOTOR_KURBELWELLE - - - - 22 - -
CAN_RX_QUALIFIER_GESCHWINDIGKEIT_FAHRZEUG_SCHWERPUNKT 0xD2DB STAT_CAN_RX_QUALIFIER_GESCHWINDIGKEIT_FAHRZEUG_SCHWERPUNKT STATE_VS_CAN 0-n QU_V_VEH_COG High unsigned char QUALIFIER_GESCHWINDIGKEIT_FAHRZEUG_SCHWERPUNKT - - - - 22 - -
CAN_RX_STEUERUNG_BASIS_TEILNETZE 0xD2DC STAT_CAN_RX_STEUERUNG_BASIS_TEILNETZE_WERT STATE_CTL_BAS_PTL_NET - STATE_CTL_BAS_PTL_NET High unsigned char - 1.0 1.0 0.0 - 22 - -
CAN_RX_RESTLAUFLEISTUNG_SCR_ADDITIV 0xD2DF STAT_CAN_RX_RESTLAUFLEISTUNG_SCR_ADDITIV_WERT DIST_AVL_RAG_VOL_TANK_ECU_ENVD km DIST_AVL_RAG_VOL_TANK_ECU_ENVD High unsigned int - 1.0 1.0 0.0 - 22 - -
CAN_TX_ANFORDERUNG_MIL_DIAGNOSE_OBD_SCR 0xD2E0 STAT_CAN_TX_ANFORDERUNG_MIL_DIAGNOSE_OBD_SCR LV_MIL_REQ_ON 0-n LV_MIL_REQ_ON High unsigned int ANFORDERUNG_MIL_DIAGNOSE_OBD_SCR - - - - 22 - -
CAN_TX_STATUS_SYSTEM_FEHLER_OBD_SCR 0xD2E1 - LF_DWIS_REQ_EXTN Bit LF_DWIS_REQ_EXTN High BITFIELD BF_STATUS_SYSTEM_FEHLER_OBD_SCR - - - - 22 - -
CAN_TX_STATUS_SPERRE_SCR_SYSTEM 0xD2E2 - STATE_SCR_LOCK_TMP Bit ST_ILK_SCRS High BITFIELD BF_STATUS_SPERRE_SCR_SYSTEM - - - - 22 - -
CAN_TX_IST_BEREITSTELLUNG_EINSPRITZMENGE_SCR_ADDITIV 0xD2E3 STAT_CAN_TX_IST_BEREITSTELLUNG_EINSPRITZMENGE_SCR_ADDITIV_WERT MASS_RAG_AVL_SCR g MASS_RAG_AVL_SCR High unsigned int - 0.001 1.0 0.0 - 22 - -
CAN_TX_LIM_BEREITSTELLUNG_EINSPRITZMENGE_SCR_ADDITIV 0xD2E4 STAT_CAN_TX_LIM_BEREITSTELLUNG_EINSPRITZMENGE_SCR_ADDITIV_WERT MFL_RAG_TAR_INJ_LIM_MAX[0] mg/s MFL_RAG_TAR_INJ_LIM_MAX[0] High unsigned int - 0.0625 1.0 0.0 - 22 - -
CAN_TX_STATUS_BEREITSTELLUNG_SCR_ADDITIV 0xD2E5 - LV_ENA_RAG_INJ Bit LV_ENA_RAG_INJ High BITFIELD BF_STATUS_BEREITSTELLUNG_SCR_ADDITIV - - - - 22 - -
CAN_TX_STATUS_INITIALISIERUNG_FILTER_WERT_SCR_ADDITIV 0xD2E6 STAT_CAN_TX_STATUS_INITIALISIERUNG_FILTER_WERT_SCR_ADDITIV LV_M_RAG_AVL_SYN_RASL 0-n tbd High unsigned char STATUS_INITIALISIERUNG_FILTER_WERT_SCR_ADDITIV - - - - 22 - -
CAN_TX_IST_QUALITAET_SCR_ADDITIV 0xD2E7 STAT_CAN_TX_IST_QUALITAET_SCR_ADDITIV_WERT CONC_RAG_VLD % CONC_RAG_VLD High unsigned int - 0.01 1.0 -10.0 - 22 - -
CAN_TX_TEMPERATUR_SCR_ADDITIV 0xD2E8 STAT_CAN_TX_TEMPERATUR_SCR_ADDITIV_WERT TEMP_RAG_TANK °C TEMP_RAG_TANK High unsigned int - 0.0625 1.0 -273.15 - 22 - -
CAN_TX_STATUS_RESTLAUFLEISTUNG_SCR_ADDITIV 0xD2E9 STAT_CAN_TX_STATUS_RESTLAUFLEISTUNG_SCR_ADDITIV_WERT DIST_AVL_RAG_VOL_TANK_ENVD km DIST_AVL_RAG_VOL_TANK_ENVD High unsigned int - 1.0 1.0 0.0 - 22 - -
CAN_TX_STATUS_NACHTANKEN_SCR_ADDITIV 0xD2EA STAT_CAN_TX_STATUS_NACHTANKEN_SCR_ADDITIV LV_RAG_TANK_FILL_DET_EXTN_ACT 0-n ST_RFG_SCRA High unsigned char STATUS_NACHTANKEN_SCR_ADDITIV - - - - 22 - -
CAN_TX_STATUS_FUELLSTAND_GEBER_SCR_ADDITIV 0xD2EB STAT_CAN_TX_STATUS_FUELLSTAND_GEBER_SCR_ADDITIV STATE_RAG_TANK_VOL_WARN_LVL 0-n STATE_RAG_TANK_VOL_WARN_LVL High unsigned char STATUS_FUELLSTAND_GEBER_SCR_ADDITIV - - - - 22 - -
CAN_TX_STATUS_FUELLSTAND_NIVEAU_SCR_ADDITIV 0xD2EC STAT_CAN_TX_STATUS_FUELLSTAND_NIVEAU_SCR_ADDITIV STATE_RAG_VOL_TANK_LEVEL 0-n ST_FLLV_LEV_SCRA High unsigned char STATUS_FUELLSTAND_NIVEAU_SCR_ADDITIV - - - - 22 - -
CAN_TX_VERHAELTNIS_GEMISCH_SCR_ADDITIV 0xD2ED STAT_CAN_TX_VERHAELTNIS_GEMISCH_SCR_ADDITIV_WERT RAG_VOL_FILL_BFR_FILL_PERC % RAG_VOL_FILL_BFR_FILL_PERC High unsigned char - 0.390625 1.0 0.0 - 22 - -
CAN_TX_FUELLSTAND_SCR_ADDITIV 0xD2EE STAT_CAN_TX_FUELLSTAND_SCR_ADDITIV_WERT RAG_VOL_TANK_PERC % RAG_VOL_TANK_PERC High unsigned char - 0.39215686 1.0 0.0 - 22 - -
CAN_TX_NACHFUELLMENGE_SCR_ADDITIV 0xD2EF STAT_CAN_TX_NACHFUELLMENGE_SCR_ADDITIV_WERT RAG_VOL_TANK_MAX_FILL l RAG_VOL_TANK_MAX_FILL High unsigned int - 0.00097656 1.0 0.0 - 22 - -
CAN_TX_STATUS_IST_QUALITAET_SCR_ADDITIV 0xD3F9 STAT_CAN_TX_STATUS_IST_QUALITAET_SCR_ADDITIV STATE_CONC_RAG_VLD 0-n STATE_CONC_RAG_VLD High unsigned int TAB_CAN_TX_STATUS_IST_QUALITAET_SCR_ADDITIV - - - - 22 - -
CAN_TX_ID_ENERGIE_BORDNETZ_VERBRAUCHER_STROM_FEPM 0xD3FA STAT_CAN_TX_ID_ENERGIE_BORDNETZ_VERBRAUCHER_STROM_FEPM_WERT EGY_IDX_CUR_BN_SCR - EGY_IDX_CUR_BN_SCR High unsigned int - 1.0 1.0 0.0 - 22 - -
CAN_TX_IST_STROM_VERBRAUCHER_FEPM 0xD3FB STAT_CAN_TX_IST_STROM_VERBRAUCHER_FEPM_WERT CUR_VALUE_AV_SCR A CUR_VALUE_AV_SCR High unsigned int - 1.0 1.0 0.0 - 22 - -
CAN_TX_VERBRAUCHER_STROM_VORAUSSAGE_FEPM 0xD3FC STAT_CAN_TX_VERBRAUCHER_STROM_VORAUSSAGE_FEPM_WERT CUR_VALUE_PRED_SCR A CUR_VALUE_PRED_SCR High unsigned char - 1.0 1.0 0.0 - 22 - -
CAN_TX_VERBRAUCHER_STROM_BEDARF_FEPM 0xD3FD STAT_CAN_TX_VERBRAUCHER_STROM_BEDARF_FEPM_WERT CUR_VALUE_RSV_SCR A CUR_VALUE_RSV_SCR High unsigned char - 1.0 1.0 0.0 - 22 - -
CAN_TX_VERBRAUCHER_STROM_VERFUEGBAR_FEPM 0xD3FE STAT_CAN_TX_VERBRAUCHER_STROM_VERFUEGBAR_FEPM_WERT CUR_VALUE_AVL_SCR A CUR_VALUE_AVL_SCR High unsigned char - 1.0 1.0 0.0 - 22 - -
CAN_TX_VERBRAUCHER_KLASSE_FEPM 0xD3FF STAT_CAN_TX_VERBRAUCHER_KLASSE_FEPM CUR_CLAS_SCR 0-n CUR_CLAS_SCR High unsigned char VERBRAUCHER_KLASSE_FEPM - - - - 22 - -
FOERDERPUMPE_FEHLER_HIGH_BYTE 0xD46B - LF_ERR_STATE_RAG_PUMP_CTL (high word) Bit LF_ERR_STATE_RAG_PUMP_CTL (high word) High BITFIELD BF_FOERDERPUMPE_FEHLER_HIGH_BYTE - - - - 22 - -
FOERDERPUMPE_FEHLER_LOW_BYTE 0xD46C - LF_ERR_STATE_RAG_PUMP_CTL (low word) Bit LF_ERR_STATE_RAG_PUMP_CTL (low word) High BITFIELD BF_FOERDERPUMPE_FEHLER_LOW_BYTE - - - - 22 - -
DWIS_ANFORDERUNG_CCM 0xD46D - LF_DWIS_FAIL_EXTN Bit LF_DWIS_FAIL_EXTN High BITFIELD BF_DWIS_ANFORDERUNG_TAMPERING - - - - 22 - -
DWIS_ANFORDERUNG_GRUPPE 0xD46E - LF_DWIS_REQ_GRP Bit LF_DWIS_REQ_GRP High BITFIELD BF_DWIS_ANFORDERUNG_GRUPPE - - - - 22 - -
AKTIVTANKHEIZUNG_PWM 0xD48F STAT_AKTIVTANKHEIZUNG_PWM_WERT PWM_WUP_RAG_HEAT[0] % PWM_WUP_RAG_HEAT[0] High unsigned int - 0.00610352 1.0 0.0 - 22 - -
DOSIERLEITUNGSHEIZUNG_PWM 0xD490 STAT_DOSIERLEITUNGSHEIZUNG_PWM_WERT PWM_WUP_RAG_HEAT[1] % PWM_WUP_RAG_HEAT[1] High unsigned int - 0.00610352 1.0 0.0 - 22 - -
AKTIVTANKHEIZUNG_AKTIV 0xD491 STAT_AKTIVTANKHEIZUNG_AKTIV LV_RAG_HEAT_ACT[0] 0/1 LV_RAG_HEAT_ACT[0] High unsigned int - - - - - 22 - -
DOSIERLEITUNGSHEIZUNG_AKTIV 0xD492 STAT_DOSIERLEITUNGSHEIZUNG_AKTIV LV_RAG_HEAT_ACT[1] 0/1 LV_RAG_HEAT_ACT[1] High unsigned int - - - - - 22 - -
AKTIVTANKHEIZUNG_STROM_ROHWERT 0xD493 STAT_AKTIVTANKHEIZUNG_STROM_ROHWERT_WERT VP_CFB_RAG_HEAT[0] V VP_CFB_RAG_HEAT[0] High unsigned int - 0.00015258 1.0 0.0 - 22 - -
DOSIERLEITUNGSHEIZUNG_STROM_ROHWERT 0xD494 STAT_DOSIERLEITUNGSHEIZUNG_STROM_ROHWERT_WERT VP_CFB_RAG_HEAT[1] V VP_CFB_RAG_HEAT[1] High unsigned int - 0.00015258 1.0 0.0 - 22 - -
AKTIVTANKHEIZUNG_STROM 0xD495 STAT_AKTIVTANKHEIZUNG_STROM_WERT CFB_RAG_HEAT[0] A CFB_RAG_HEAT[0] High unsigned int - 0.00097656 1.0 0.0 - 22 - -
DOSIERLEITUNGSHEIZUNG_STROM 0xD496 STAT_DOSIERLEITUNGSHEIZUNG_STROM_WERT CFB_RAG_HEAT[1] A CFB_RAG_HEAT[1] High unsigned int - 0.00097656 1.0 0.0 - 22 - -
AKTIVTANKHEIZUNG_LEISTUNG 0xD497 STAT_AKTIVTANKHEIZUNG_LEISTUNG_WERT POW_RAG_HEAT_TANK_CNS W POW_RAG_HEAT_TANK_CNS High unsigned int - 0.1 1.0 0.0 - 22 - -
DOSIERLEITUNGSHEIZUNG_LEISTUNG 0xD498 STAT_DOSIERLEITUNGSHEIZUNG_LEISTUNG_WERT POW_RAG_HEAT_TUBE_CNS W POW_RAG_HEAT_TUBE_CNS High unsigned int - 0.1 1.0 0.0 - 22 - -
FOERDERPUMPE_STROM 0xD49B STAT_FOERDERPUMPE_STROM_WERT CUR_EM_RMS A CUR_EM_RMS High unsigned int - 0.001 1.0 0.0 - 22 - -
FOERDERPUMPE_DREHZAHL 0xD49C STAT_FOERDERPUMPE_DREHZAHL_WERT N_RAG_PUMP_MES 1/min N_RAG_PUMP_MES High unsigned int - 1.0 1.0 0.0 - 22 - -
DRUCKREGELUNG_AKTIV 0xD49D STAT_DRUCKREGELUNG_AKTIV LV_PRS_CTL_RAG_ON 0/1 LV_PRS_CTL_RAG_ON High unsigned int - - - - - 22 - -
DRUCKREGELUNG_GEPRUEFT 0xD49E STAT_DRUCKREGELUNG_GEPRUEFT LV_PRS_CTL_RAG_CHK_OK 0/1 LV_PRS_CTL_RAG_CHK_OK High unsigned int - - - - - 22 - -
DOSIERLEITUNG_FUELLUNGSGRAD_NACH_RUECKSAUGEN 0xD49F STAT_DOSIERLEITUNG_FUELLUNGSGRAD_NACH_RUECKSAUGEN_WERT RAG_VOL_PUMP_DOWN ml RAG_VOL_PUMP_DOWN High unsigned int - 0.01 1.0 0.0 - 22 - -
TEMPERATUR_LEVELSENSOR_AKTIVTANK_ROHWERT 0xD4A0 STAT_TEMPERATUR_LEVELSENSOR_AKTIVTANK_ROHWERT_WERT TEMP_RAG_TANK_SENS °C TEMP_RAG_TANK_SENS High unsigned int - 0.0625 1.0 -273.15 - 22 - -
TEMPERATUR_AKTIVTANK 0xD4A1 STAT_TEMPERATUR_LEVELSENSOR_AKTIVTANK_WERT TEMP_RAG_SYS °C TEMP_RAG_SYS High unsigned int - 0.0625 1.0 -273.15 - 22 - -
TEMPERATUR_DRUCKSENSOR_ROHWERT 0xD4A2 STAT_TEMPERATUR_DRUCKSENSOR_ROHWERT_WERT TEMP_PRS_RAG_SENS °C TEMP_PRS_RAG_SENS High unsigned int - 0.0625 1.0 -273.15 - 22 - -
FOERDERPUMPE_DREHZAHL_SOLLWERT 0xD4A3 STAT_FOERDERPUMPE_DREHZAHL_SOLL_WERT N_SP_EM 1/min N_SP_EM High unsigned int - 1.0 1.0 0.0 - 22 - -
DRUCK_ROHWERT 0xD4A4 STAT_DRUCK_ROHWERT_WERT PRS_RAG_SENT (relativ) bar PRS_RAG_SENT High signed int - 0.00097656 1.0 0.0 - 22 - -
DRUCK_GEFILTERT 0xD4A5 STAT_DRUCK_GEFILTERT_WERT PRS_RAG_FIL (absolut) bar PRS_RAG_FIL High signed int - 0.00097656 1.0 0.0 - 22 - -
DRUCK_NOMINAL 0xD4A6 STAT_DRUCK_NOMINAL_WERT PRS_RAG_SP bar PRS_RAG_SP High signed int - 0.00097656 1.0 0.0 - 22 - -
DRUCK_ABWEICHUNG_VON_NOMINAL 0xD4A7 STAT_DRUCK_ABWEICHUNG_VON_NOMINAL_WERT PRS_CTL_DIF_RAG_FIL bar PRS_CTL_DIF_RAG_FIL High signed int - 0.00097656 1.0 0.0 - 22 - -
SCHALLGESCHWINDIGKEIT_ROHWERT 0xD4A8 STAT_SCHALLGESCHWINDIGKEIT_ROHWERT_WERT VEL_RAG_UCLS m/s VEL_RAG_UCLS High unsigned int - 0.1 1.0 0.0 - 22 - -
QUALITAET_ROHWERT 0xD4A9 STAT_QUALITAET_ROHWERT_WERT CONC_RAG_SENS % CONC_RAG_SENS High unsigned int - 0.01 1.0 -10.0 - 22 - -
QUALITAET 0xD4AA STAT_QUALITAET_WERT CONC_RAG_VLD % CONC_RAG_VLD High unsigned int - 0.01 1.0 -10.0 - 22 - -
LEVELSENSOR_AKTIVTANK_FEHLER 0xD4AB - LF_STATE_RAG_UCLS_SENT Bit LF_STATE_RAG_UCLS_SENT High BITFIELD BF_LEVELSENSOR_AKTIVTANK_FEHLER - - - - 22 - -
LEVELSIGNAL_GUELTIG_AKTIVTANK_DIREKT_PIEZO 0xD4AC STAT_LEVELSIGNAL_GUELTIG_AKTIVTANK_DIREKT_PIEZO LV_RAG_RTL_INFO_NOT_REL 0/1 LV_RAG_RTL_INFO_NOT_REL High unsigned int - - - - - 22 - -
LEVELSIGNAL_GUELTIG_AKTIVTANK_KOMBI_PIEZO 0xD4AD STAT_LEVELSIGNAL_GUELTIG_AKTIVTANK_KOMBI_PIEZO LV_RAG_RTL_INFO_NOT_VLD_2 0/1 LV_RAG_RTL_INFO_NOT_VLD_2 High unsigned int - - - - - 22 - -
FUELLSTAND_AKTIVTANK_DIREKT_PIEZO_ROHWERT 0xD4AE STAT_FUELLSTAND_AKTIVTANK_DIREKT_PIEZO_ROHWERT_WERT RTL_MES_SENS[0] mm RTL_MES_SENS[0] High unsigned int - 0.01 1.0 0.0 - 22 - -
FUELLSTAND_AKTIVTANK_KOMBI_PIEZO_ROHWERT 0xD4AF STAT_FUELLSTAND_AKTIVTANK_KOMBI_PIEZO_ROHWERT_WERT RTL_MES_SENS[1] mm RTL_MES_SENS[1] High unsigned int - 0.01 1.0 0.0 - 22 - -
FUELLSTAND_AKTIVTANK_DIREKT_PIEZO 0xD4B0 STAT_FUELLSTAND_AKTIVTANK_DIREKT_PIEZO_WERT RTL_MES_SENS_FIL[0] mm RTL_MES_SENS_FIL[0] High unsigned int - 0.01 1.0 0.0 - 22 - -
FUELLSTAND_AKTIVTANK_KOMBI_PIEZO 0xD4B1 STAT_FUELLSTAND_AKTIVTANK_KOMBI_PIEZO_WERT RTL_MES_SENS_FIL[1] mm RTL_MES_SENS_FIL[1] High unsigned int - 0.01 1.0 0.0 - 22 - -
AMPLITUDE_ECHO_1_DIREKT_PIEZO 0xD4B2 STAT_AMPLITUDE_ECHO_1_DIREKT_PIEZO_WERT AMPL_RAG_UCLS[3] - AMPL_RAG_UCLS[3] High unsigned int - 0.1 1.0 0.0 - 22 - -
AMPLITUDE_ECHO_1_KOMBI_PIEZO 0xD4B3 STAT_AMPLITUDE_ECHO_2_DIREKT_PIEZO_WERT AMPL_RAG_UCLS[0] - AMPL_RAG_UCLS[0] High unsigned int - 0.1 1.0 0.0 - 22 - -
AMPLITUDE_ECHO_2_KOMBI_PIEZO 0xD4B4 STAT_AMPLITUDE_ECHO_1_KOMBI_PIEZO_WERT AMPL_RAG_UCLS[1] - AMPL_RAG_UCLS[1] High unsigned int - 0.1 1.0 0.0 - 22 - -
AMPLITUDE_ECHO_3_KOMBI_PIEZO 0xD4B5 STAT_AMPLITUDE_ECHO_2_KOMBI_PIEZO_WERT AMPL_RAG_UCLS[2] - AMPL_RAG_UCLS[2] High unsigned int - 0.1 1.0 0.0 - 22 - -
FUELLMENGE_AKTIVTANK_DIREKT_PIEZO_UNGEFILTERT 0xD4B6 STAT_FUELLMENGE_AKTIVTANK_DIREKT_PIEZO_UNGEFILTERT_WERT RTL_CONT_SENS_VCT[0] l RTL_CONT_SENS_VCT[0] High unsigned int - 0.1 1.0 0.0 - 22 - -
FUELLMENGE_AKTIVTANK_KOMBI_PIEZO_UNGEFILTERT 0xD4B7 STAT_FUELLMENGE_AKTIVTANK_KOMBI_PIEZO_UNGEFILTERT_WERT RTL_CONT_SENS_VCT[1] l RTL_CONT_SENS_VCT[1] High unsigned int - 0.1 1.0 0.0 - 22 - -
ZEITDAUER_SPULENHEIZEN 0xD4B8 STAT_ZEITDAUER_SPULENHEIZEN_WERT T_TOT_RDU_ANST_HEAT[0] s T_TOT_RDU_ANST_HEAT[0] High unsigned long - 0.01 1.0 0.0 - 22 - -
BATTERIESPANNUNG_SCR 0xD4C3 STAT_BATTERIESPANNUNG_WERT Batteriespannung gemessen vom SCR Steuergerät. VB_H_RES. V VB_H_RES High signed int - 0.01953125 1.0 0.0 - 22 - -
FUELLMENGE_AKTIVTANK_SCHNELL_GEFILTERT 0xD4D0 STAT_FUELLMENGE_AKTIVTANK_SCHNELL_GEFILTERT_WERT RTL_VOL_FIL_H_RES[0] l RTL_VOL_FIL_H_RES[0] High unsigned int - 0.00097656 1.0 0.0 - 22 - -
FUELLMENGE_AKTIVTANK_LANGSAM_GEFILTERT 0xD4D1 STAT_FUELLMENGE_AKTIVTANK_LANGSAM_GEFILTERT_WERT RTL_VOL_FIL_H_RES[1] l RTL_VOL_FIL_H_RES[1] High unsigned int - 0.00097656 1.0 0.0 - 22 - -
FUELLMENGE_AKTIVTANK_RELATIV 0xD4D2 STAT_FUELLMENGE_AKTIVTANK_RELATIV_WERT RAG_VOL_TANK_PERC % RAG_VOL_TANK_PERC High unsigned int - 0.39215686 1.0 0.0 - 22 - -
NACHFUELLBARE_MENGE_AKTIVTANK_GEFILTERT 0xD4D3 STAT_NACHFUELLBARE_MENGE_AKTIVTANK_GEFILTERT_WERT RAG_VOL_TANK_MAX_FILL l RAG_VOL_TANK_MAX_FILL High unsigned int - 0.00097656 1.0 0.0 - 22 - -
FREIGABEMASKE_FUER_FUELLSTANDSFUNKTION_AKTIVTANK 0xD4D4 - LF_RTL_SENS_MES_VLD_DET Bit LF_RTL_SENS_MES_VLD_DET High BITFIELD BF_FREIGABEMASKE_FUER_FUELLSTANDSFUNKTION_AKTIVTANK - - - - 22 - -
NACHTANKERKENNUNG 0xD4D6 STAT_NACHTANKERKENNUNG LV_RS_SENS_REAC_FILL 0/1 LV_RS_SENS_REAC_FILL High unsigned int - - - - - 22 - -
AUFTAUZEIT_AKTUELL 0xD4D7 STAT_AUFTAUZEIT_AKTUELL_WERT T_TOT_DUR_CUR_WUP_RAG_HEAT s T_TOT_DUR_CUR_WUP_RAG_HEAT High unsigned int - 0.1 1.0 0.0 - 22 - -
AUFTAUZEIT_VORGABE 0xD4D8 STAT_AUFTAUZEIT_VORGABE_WERT T_MAX_DUR_CUR_WUP_RAG_HEAT_COR s T_MAX_DUR_CUR_WUP_RAG_HEAT_COR High unsigned int - 0.1 1.0 0.0 - 22 - -
AUFTAUZEIT_EPA 0xD4D9 STAT_AUFTAUZEIT_EPA_WERT T_MAX_DUR_CUR_WUP_RAG_HEAT s T_MAX_DUR_CUR_WUP_RAG_HEAT High unsigned int - 0.1 1.0 0.0 - 22 - -
AUFTAUEN_AKTIV 0xD4DA STAT_AUFTAUEN_AKTIV LV_RAG_WUP_HEAT_ACT 0/1 LV_RAG_WUP_HEAT_ACT High unsigned int - - - - - 22 - -
AUFTAUEN_ABGESCHLOSSEN 0xD4DB STAT_AUFTAUEN_ABGESCHLOSSEN LV_RAG_WUP_HEAT_CMPL 0/1 LV_RAG_WUP_HEAT_CMPL High unsigned int - - - - - 22 - -
TEMPERATUR_AKTIVTANK_GESPEICHERT 0xD4DC STAT_TEMPERATUR_AKTIVTANK_GESPEICHERT_WERT TEMP_RAG_SYS_HEAT_ST °C TEMP_RAG_SYS_HEAT_ST High unsigned int - 0.0625 1.0 -273.15 - 22 - -
AKTIVTANK_GEFROREN 0xD4DE STAT_AKTIVTANK_GEFROREN LV_RAG_TANK_ICE 0/1 LV_RAG_TANK_ICE High unsigned int - - - - - 22 - -
LEVELSENSOR_PASSIVTANK_ANZAHL_ECHOS 0xD4DF - STATE_RAG_TANK_SENS Bit STATE_RAG_TANK_SENS High BITFIELD BF_LEVELSENSOR_PASSIVTANK_FEHLER - - - - 22 - -
TEMPERATUR_PASSIVTANK 0xD4E1 STAT_TEMPERATUR_PASSIVTANK_WERT TEMP_RAG_TANK_PAS °C TEMP_RAG_TANK_PAS High unsigned int - 0.0625 1.0 -273.15 - 22 - -
LEVELSENSOR_PASSIVTANK_SIGNALZEIT_ROHWERT 0xD4E2 STAT_LEVELSENSOR_PASSIVTANK_SIGNALZEIT_ROHWERT_TEXT T_PER_L_PWM_RAG_TANK_SENS[x] Array mit 5 Elementen TEXT T_PER_L_PWM_RAG_TANK_SENS[0..4] High string[10] - 0.01 1.0 0.0 - 22 - -
LEVELSENSOR_PASSIVTANK_SIGNALPERIODE_ROHWERT 0xD4E3 STAT_LEVELSENSOR_PASSIVTANK_SIGNALPERIODE_ROHWERT_TEXT T_PER_PWM_RAG_TANK_SENS[x] Array mit 5 Elementen TEXT T_PER_PWM_RAG_TANK_SENS[0..4] High string[10] - 0.01 1.0 0.0 - 22 - -
FREIGABEMASKE_FUER_FUELLSTANDSFUNKTION_PASSIVTANK 0xD4E4 - LF_RTL_SENS_PAS_MES_VLD_DET Bit LF_RTL_SENS_PAS_MES_VLD_DET High BITFIELD BF_FREIGABEMASKE_FUER_FUELLSTANDSFUNKTION_PASSIVTANK - - - - 22 - -
NACHFUELLBARE_MENGE_PASSIVTANK_GEFILTERT 0xD4E5 STAT_NACHFUELLBARE_MENGE_PASSIVTANK_GEFILTERT_WERT RAG_VOL_TANK_PAS_MAX_FILL l RAG_VOL_TANK_PAS_MAX_FILL High unsigned int - 0.00097656 1.0 0.0 - 22 - -
PASSIVTANK_VERBAUT 0xD4E6 STAT_PASSIVTANK_VERBAUT LV_RAG_TANK_PAS_CPT_AVL 0-n LV_RAG_TANK_PAS_CPT_AVL High unsigned int PASSIVTANK_VERBAUT - - - - 22 - -
LANGZEIT_UMPUMPMENGE 0xD4E7 STAT_LANGZEIT_UMPUMPMENGE_WERT RAG_VOL_TOT_TRF_PUMP l RAG_VOL_TOT_TRF_PUMP High unsigned int - 0.1 1.0 0.0 - 22 - -
TEMPERATUR_SCR_STEUERGERAET 0xD4E8 STAT_TEMPERATUR_SCR_STEUERGERAET_WERT TEMP_HEAT_ECU °C TEMP_HEAT_ECU High unsigned int - 0.75 1.0 -48.0 - 22 - -
ZUSTAND_SCR_SYSTEM 0xD4E9 STAT_ZUSTAND_SCR_SYSTEM STATE_ECU 0-n STATE_ECU High unsigned int SCR_SYSTEM_ZUSTAND - - - - 22 - -
NACHLAUF_GESTARTET 0xD4EA STAT_NACHLAUF_GESTARTET LV_PWL 0/1 LV_PWL High unsigned int - - - - - 22 - -
NACHLAUF_AKTIV 0xD4EC STAT_NACHLAUF_AKTIV LV_PWL_ACT 0/1 LV_PWL_ACT High unsigned int - - - - - 22 - -
NACHLAUF_ABGESCHLOSSEN 0xD4ED STAT_NACHLAUF_ABGESCHLOSSEN LV_PWL_END 0/1 LV_PWL_END High unsigned int - - - - - 22 - -
NACHLAUFZEIT 0xD4EE STAT_NACHLAUFZEIT_WERT T_PWL_LST_DC s T_PWL_LST_DC High unsigned int - 0.1 1.0 0.0 - 22 - -
ZEIT_SEIT_MOTORSTOPP 0xD4EF STAT_ZEIT_SEIT_MOTORSTOPP_WERT T_ES_CUS min T_ES_CUS High unsigned int - 1.0 1.0 0.0 - 22 - -
ZEIT_SEIT_MOTORSTART 0xD4F0 STAT_ZEIT_SEIT_MOTORSTART_WERT T_AST s T_AST High unsigned int - 0.1 1.0 0.0 - 22 - -
TEMPERATUR_DOSIERVENTIL 0xD4F1 STAT_TEMPERATUR_DOSIERVENTIL_WERT TEMP_RDU_COIL[0] °C TEMP_RDU_COIL[0] High unsigned int - 0.0625 1.0 -273.15 - 22 - -
WIDERSTAND_DOSIERVENTIL_GEMESSEN 0xD4F2 STAT_WIDERSTAND_DOSIERVENTIL_GEMESSEN_WERT R_RDU_MES[0] Ohm R_RDU_MES[0] High unsigned int - 0.00195313 1.0 0.0 - 22 - -
WIDERSTAND_DOSIERVENTIL_OFFSET_ROHWERT 0xD4F3 STAT_WIDERSTAND_DOSIERVENTIL_ROHWERT_WERT R_RAW_RDU_PIN_CBL[0] Ohm R_RAW_RDU_PIN_CBL[0] High signed int - 0.00195313 1.0 0.0 - 22 - -
WIDERSTAND_DOSIERVENTIL_OFFSETWERT 0xD4F4 STAT_WIDERSTAND_DOSIERVENTIL_OFFSETWERT_WERT R_RDU_PIN_CBL[0] Ohm R_RDU_PIN_CBL[0] High signed int - 0.00195313 1.0 0.0 - 22 - -
STROM_DOSIERVENTIL 0xD4F5 STAT_STROM_DOSIERVENTIL_WERT CFB_RDU[0] A CFB_RDU[0] High unsigned int - 0.00097656 1.0 0.0 - 22 - -
TASTVERHAELTNIS_DOSIERVENTIL_ANFORDERUNG 0xD4F6 STAT_TASTVERHAELTNIS_DOSIERVENTIL_ANFORDERUNG_WERT PWM_RAG_INJ[0] % PWM_RAG_INJ[0] High unsigned int - 0.00610352 1.0 0.0 - 22 - -
FREQUENZ_DOSIERVENTIL_ANFORDERUNG 0xD4F7 STAT_FREQUENZ_DOSIERVENTIL_ANFORDERUNG_WERT FRQ_RAG_INJ[0] Hz FRQ_RAG_INJ High unsigned int - 0.015625 1.0 0.0 - 22 - -
MASSENSTROM_DOSIERVENTIL 0xD4F9 STAT_MASSENSTROM_DOSIERVENTIL_WERT MFL_RAG_AVL_SCR mg/s MFL_RAG_AVL_SCR High unsigned int - 0.015625 1.0 0.0 - 22 - -
LANGZEIT_DOSIERMENGE 0xD4FA STAT_LANGZEIT_DOSIERMENGE_WERT M_RAG_CNS_TOT_ENVD g M_RAG_CNS_TOT_ENVD High unsigned int - 32.768 1.0 0.0 - 22 - -
DOSIERVENTIL_FEHLER 0xD4FB STAT_DOSIERVENTIL_FEHLER LV_RDU_STUCK_DET[0] 0/1 LV_RDU_STUCK_DET[0] High unsigned int - - - - - 22 - -
KILOMETER_AKTUELLER_DC 0xD4FE STAT_KILOMETER_AKTUELLER_DC_WERT DIST_DC_ENVD km DIST_DC_ENVD High unsigned int - 0.1 1.0 0.0 - 22 - -
ZEITDAUER_UEBERTEMPERATUR_DOSIERVENTIL 0xD4FF STAT_ZEITDAUER_UEBERTEMPERATUR_DOSIERVENTIL_WERT T_TOT_TEMP_RDU_OVER_MAX[0] s T_TOT_TEMP_RDU_OVER_MAX_ENVD[0] High unsigned int - 1.0 1.0 0.0 - 22 - -
SPULENHEIZEN_AKTIV 0xD508 STAT_SPULENHEIZEN_AKTIV LV_TEMP_RDU_COIL_CTL_ON[0] 0/1 LV_TEMP_RDU_COIL_CTL_ON[0] High unsigned char - - - - - 22 - -
SPULENHEIZEN_GEREGELT_AKTIV 0xD509 STAT_SPULENHEIZEN_GEREGELT_AKTIV LV_TEMP_RDU_COIL_CTL_HEAT_CYC_L[0] 0/1 LV_TEMP_RDU_COIL_CTL_HEAT_CYC_L[0] High unsigned char - - - - - 22 - -
LAUFZEIT_ECHO_1_DIREKT_PIEZO 0xD6E0 STAT_LAUFZEIT_ECHO_1_DIREKT_PIEZO_WERT RT_RAG_UCLS[3] µs RT_RAG_UCLS[3] High unsigned int - 0.015625 1.0 0.0 - 22 - -
LAUFZEIT_ECHO_1_KOMBI_PIEZO 0xD6E1 STAT_LAUFZEIT_ECHO_1_KOMBI_PIEZO_WERT RT_RAG_UCLS[0] µs RT_RAG_UCLS[0] High unsigned int - 0.015625 1.0 0.0 - 22 - -
LAUFZEIT_ECHO_2_KOMBI_PIEZO 0xD6E2 STAT_LAUFZEIT_ECHO_2_KOMBI_PIEZO_WERT RT_RAG_UCLS[1] µs RT_RAG_UCLS[1] High unsigned int - 0.015625 1.0 0.0 - 22 - -
LAUFZEIT_ECHO_3_KOMBI_PIEZO 0xD6E3 STAT_LAUFZEIT_ECHO_3_KOMBI_PIEZO_WERT RT_RAG_UCLS[2] µs RT_RAG_UCLS[2] High unsigned int - 0.015625 1.0 0.0 - 22 - -
SIGNALGUETE_ECHO_1_DIREKT_PIEZO 0xD6E4 STAT_SIGNALGUETE_ECHO_1_DIREKT_PIEZO_WERT QLY_RAG_UCLS[3] - QLY_RAG_UCLS[3] High unsigned int - 1.0 1.0 0.0 - 22 - -
SIGNALGUETE_ECHO_1_KOMBI_PIEZO 0xD6E5 STAT_SIGNALGUETE_ECHO_1_KOMBI_PIEZO_WERT QLY_RAG_UCLS[0] - QLY_RAG_UCLS[0] High unsigned int - 1.0 1.0 0.0 - 22 - -
SIGNALGUETE_ECHO_2_KOMBI_PIEZO 0xD6E6 STAT_SIGNALGUETE_ECHO_2_KOMBI_PIEZO_WERT QLY_RAG_UCLS[1] - QLY_RAG_UCLS[1] High unsigned int - 1.0 1.0 0.0 - 22 - -
SIGNALGUETE_ECHO_3_KOMBI_PIEZO 0xD6E7 STAT_SIGNALGUETE_ECHO_3_KOMBI_PIEZO_WERT QLY_RAG_UCLS[2] - QLY_RAG_UCLS[2] High unsigned int - 1.0 1.0 0.0 - 22 - -
ZEIT_REHEATING 0xD6E8 STAT_ZEIT_REHEATING_WERT T_ACT_DUR_CUR_WUP_RAG_HEAT s T_ACT_DUR_CUR_WUP_RAG_HEAT High unsigned int - 1.0 1.0 0.0 - 22 - -
FUELLSTAND_PASSIVTANK_ROHWERT 0xD6EA STAT_FUELLSTAND_PASSIVTANK_ROHWERT_WERT RTL_TANK_SENS_RAW [0] mm RTL_TANK_SENS_RAW[0] High unsigned int - 0.25 1.0 0.0 - 22 - -
FUELLMENGE_PASSIVTANK_RELATIV 0xD6EB STAT_FUELLMENGE_PASSIVTANK_RELATIV_WERT RAG_VOL_TANK_PAS_PERC % RAG_VOL_TANK_PAS_PERC High unsigned int - 0.5 1.0 0.0 - 22 - -
FUELLMENGE_PASSIVTANK_ROHWERT 0xD6EC STAT_FUELLMENGE_PASSIVTANK_ROHWERT_WERT RTL_CONT_SENS_TANK_PAS l RTL_CONT_SENS_TANK_PAS High unsigned int - 0.1 1.0 0.0 - 22 - -
FUELLMENGE_PASSIVTANK_SCHNELL_GEFILTERT 0xD6ED STAT_FUELLMENGE_PASSIVTANK_SCHNELL_GEFILTERT_WERT RTL_VOL_SENS_PAS_FIL[0] l RTL_VOL_SENS_PAS_FIL[0] High unsigned int - 0.00097656 1.0 0.0 - 22 - -
FUELLMENGE_PASSIVTANK_LANGSAM_GEFILTERT 0xD6EF STAT_FUELLMENGE_PASSIVTANK_LANGSAM_GEFILTERT_WERT RTL_VOL_SENS_PAS_FIL[1] l RTL_VOL_SENS_PAS_FIL[1] High unsigned int - 0.00097656 1.0 0.0 - 22 - -
ERSTBEFUELLUNGSSTATUS 0xD6F0 STAT_ERSTBEFUELLUNGSSTATUS LV_RAG_REAC_FILL_FIRST_CMPL 0/1 LV_RAG_REAC_FILL_FIRST_CMPL High unsigned int - - - - - 22 - -
LERNWERT_FOERDERPUMPE 0xD6F2 STAT_LERNWERT_FOERDERPUMPE_WERT RAG_VOL_PUMP_STK_FIL µl RAG_VOL_PUMP_STK_FIL High unsigned int - 0.1 1.0 0.0 - 22 - -
TEMPERATUR_DOSIERVENTIL_MAXIMAL 0xD6F3 STAT_TEMPERATUR_DOSIERVENTIL_MAXIMAL_WERT TEMP_RDU_COIL_MES_MAX[0] °C TEMP_RDU_COIL_MES_MAX[0] High unsigned int - 0.0625 1.0 -273.15 - 22 - -
PRODUKTIONSDATUM_LQS 0xD6F7 STAT_PRODUKTIONSDATUM_LQS_WERT Enthält Produktionsjahr, -Woche und -Tag des Level-Quality-Sensors. HEX DATA_PROD_NR_UCLS High unsigned int - - - - - 22 - -
PRODUKTIONSNUMMER_LQS 0xD6F8 STAT_PRODUKTIONSNUMMER_LQS_DATA Enthält die eindeutige Produktionsnummer des Level-Quality-Sensors. DATA DATA_SRL_NR_UCLS High data[8] - 1.0 1.0 0.0 - 22 - -
UMDREHUNGEN_FOERDERPUMPE_LANGZEIT 0xD6F9 STAT_UMDREHUNGEN_FOERDERPUMPE_LANGZEIT_WERT NR_RAG_PUMP_ROT_TOT - NR_RAG_PUMP_ROT_TOT High unsigned long - 1.0 1.0 0.0 - 22 - -
UMDREHUNGEN_FOERDERPUMPE_DRUCKAUFBAU_CDM 0xD6FA STAT_UMDREHUNGEN_FORDERPUMPE_DRUCKAUFBAU_CDM_WERT CTR_ROT_RAG_VOL_PUMP - CTR_ROT_RAG_VOL_PUMP High unsigned char - 1.0 1.0 0.0 - 22 - -
KAVITAETSERKENNUNG_GUELTIG 0xD6FB STAT_KAVITAETSERKENNUNG_GUELTIG LV_RAG_TANK_VAC_DET_VLD 0/1 LV_RAG_TANK_VAC_DET_VLD High unsigned int - - - - - 22 - -
KAVITAETSERKENNUNG_GUELTIG_NVMY 0xD6FC STAT_KAVITAETSERKENNUNG_GUELTIG_NVMY LV_RAG_TANK_VAC_DET_VLD_NVMY 0/1 LV_RAG_TANK_VAC_DET_VLD_NVMY High unsigned char - - - - - 22 - -
MANIPULATION 0xD6FD STAT_MANIPULATION LV_DWIS_FAIL_TOT 0/1 LV_DWIS_FAIL_TOT High unsigned char - - - - - 22 - -
AUFTAUZEIT_MAXIMAL_MSA 0xD7C0 STAT_AUFTAUZEIT_MAXIMAL_MSA_WERT T_MAX_DUR_CUR_WUP_RAG_HEAT_STST s T_MAX_DUR_CUR_WUP_RAG_HEAT_STST High unsigned int - 0.1 1.0 0.0 - 22 - -
CDM2_SUMME_NACHFUELLMENGE 0xD7C1 STAT_CDM2_SUMME_NACHFUELLMENGE_WERT RAG_VOL_FILL_SUM_CNS_ERR l RAG_VOL_FILL_SUM_CNS_ERR High unsigned int - 0.00097656 1.0 0.0 - 22 - -
TEMPERATUR_FOERDERPUMPE 0xD7C2 STAT_TEMPERATUR_FOERDERPUMPE_WERT TEMP_RAG_PUMP_MDL °C TEMP_RAG_PUMP_MDL High unsigned int - 0.0625 1.0 -273.15 - 22 - -
TEMPERATUR_FOERDERPUMPE_ZU_HOCH 0xD7C3 STAT_TEMPERATUR_FOERDERPUMPE_ZU_HOCH LV_TEMP_RAG_SYS_OVER_HEAT 0/1 LV_TEMP_RAG_SYS_OVER_HEAT High unsigned char - - - - - 22 - -
CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_GEFILTERT 0xD7C4 STAT_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_GEFILTERT_WERT VOL_PUMP_STK_STND_FIL_CNS_ERR µl VOL_PUMP_STK_STND_FIL_CNS_ERR High unsigned int - 0.1 1.0 0.0 - 22 - -
CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_ERSTER 0xD7C5 STAT_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_ERSTER_WERT VOL_PUMP_STK_STND_FIRST_CNS_ERR µl VOL_PUMP_STK_STND_FIRST_CNS_ERR High unsigned int - 0.1 1.0 0.0 - 22 - -
CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_REFERENZ 0xD7C6 STAT_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_REFERENZ_WERT VOL_PUMP_STK_STND_REF_CNS_ERR µl VOL_PUMP_STK_STND_REF_CNS_ERR High unsigned int - 0.1 1.0 0.0 - 22 - -
DRUCKREGLER_INTEGRAL_ANTEIL 0xD7C7 STAT_DRUCKREGLER_INTEGRAL_ANTEIL_WERT VFL_RAG_PUMP_I_CLL_CTL, [Mikroliter/Sekunde] - VFL_RAG_PUMP_I_CLL_CTL High signed int - 1.0 1.0 0.0 - 22 - -
DOSIERTE_MENGE_LUFTERKENNUNG 0xD7C8 STAT_DOSIERTE_MENGE_LUFTERKENNUNG_WERT M_RAG_COR_AIR_INJ_TOT mg M_RAG_COR_AIR_INJ_TOT High signed int - 0.0625 1.0 0.0 - 22 - -
DOSIERTE_MENGE_LUFTERKENNUNG_KORREKTUR 0xD7C9 STAT_DOSIERTE_MENGE_LUFTERKENNUNG_KORREKTUR_WERT M_RAG_COR_AIR_INJ_REL mg M_RAG_COR_AIR_INJ_REL High signed int - 0.0625 1.0 0.0 - 22 - -
SOFTWARE_VERSION_LQS 0xD7CA STAT_SOFTWARE_VERSION_LQS_TEXT DATA_SW_VERS_CAL_IDF_UCLS[0..3] TEXT DATA_SW_VERS_CAL_IDF_UCLS[0..3] High string[4] - 1.0 1.0 0.0 - 22 - -
PUMPENLECKAGE_ADAPTIONSKENNFELD 0xD7CB STAT_PUMPENLECKAGE_ADAPTIONSKENNFELD_DATA IP_AD_VFL_LEAK_RAG DATA IP_AD_VFL_LEAK_RAG High data[20] - 1.0 1.0 0.0 - 22 - -
PUMPENLECKAGE_ADAPTIONSWERT_MINIMUM 0xD7CC STAT_PUMPENLECKAGE_ADAPTIONSWERT_MINIMUM_WERT VFL_LEAK_RAG_AD_MIN, [Mikroliter/Sekunde] - VFL_LEAK_RAG_AD_MIN High unsigned int - 0.001 1.0 0.0 - 22 - -
PUMPENLECKAGE_ADAPTIONSWERT_MAXIMUM 0xD7CD STAT_PUMPENLECKAGE_ADAPTIONSWERT_MAXIMUM_WERT VFL_LEAK_RAG_AD_MAX [Mikroliter/Sekunde] - VFL_LEAK_RAG_AD_MAX High unsigned int - 0.001 1.0 0.0 - 22 - -
SCHUTZDOSIERUNG_MASSE_AKTUELLER_DC 0xD7CE STAT_SCHUTZDOSIERUNG_MASSE_AKTUELLER_DC_WERT MASS_RAG_TEMP_RDU_PROT_DC g MASS_RAG_TEMP_RDU_PROT_DC[0] High unsigned int - 0.02 1.0 0.0 - 22 - -
SCHUTZDOSIERUNG_ANZAHL_AKTUELLER_DC 0xD7CF STAT_SCHUTZDOSIERUNG_ANZAHL_AKTUELLER_DC_WERT CTR_RAG_TEMP_RDU_PROT_DC - CTR_RAG_TEMP_RDU_PROT_DC[0] High unsigned char - 1.0 1.0 0.0 - 22 - -
RBM_NCAT_NUMERATOR 0xD7D0 STAT_RBM_NCAT_NUMERATOR_WERT CTR_MOD_9_RBM[4] - CTR_MOD_9_RBM[4] High unsigned int - 1.0 1.0 0.0 - 22 - -
RBM_NCAT_DENOMINATOR 0xD7D1 STAT_RBM_NCAT_DENOMINATOR_WERT CTR_MOD_9_RBM[5] - CTR_MOD_9_RBM[5] High unsigned int - 1.0 1.0 0.0 - 22 - -
RBM_DENOMINATOR 0xD7D2 STAT_RBM_DENOMINATOR_DATA CTR_CDN_RBM[x] DATA CTR_CDN_RBM[x] High data[100] - 1.0 1.0 0.0 - 22 - -
RBM_NUMERATOR 0xD7D3 STAT_RBM_NUMERATOR_DATA CTR_COMP_RBM[x] DATA CTR_COMP_RBM[x] High data[100] - 1.0 1.0 0.0 - 22 - -
DOSIERMENGE_AKTUELLER_DC 0xD7D4 STAT_DOSIERMENGE_AKTUELLER_DC_WERT M_RAG_CNS_DC_ENVD mg M_RAG_CNS_DC_ENVD High unsigned int - 16.0 1.0 0.0 - 22 - -
FOERDERPUMPE_PWM_SOLL 0xD7D5 STAT_FOERDERPUMPE_PWM_SOLL_WERT PWM_EM_DUCY % PWM_EM_DUCY High unsigned int - 0.00610352 1.0 0.0 - 22 - -
FOERDERPUMPE_PWM_IST 0xD7D6 STAT_FOERDERPUMPE_PWM_IST_WERT PWM_RAG_PUMP % PWM_RAG_PUMP High unsigned int - 0.00610352 1.0 0.0 - 22 - -
CDM2_VERBRAUCH_IST_ZU_SOLL 0xD7D8 STAT_CDM2_VERBRAUCH_IST_ZU_SOLL_WERT RAG_VOL_DIF_CNS_ERR_PERC % RAG_VOL_DIF_CNS_ERR_PERC High signed int - 0.1 1.0 0.0 - 22 - -
CDM2_FUELLMENGE_AKTIVTANK_ENDE 0xD7DA STAT_CDM2_FUELLMENGE_AKTIVTANK_ENDE_WERT RTL_VOL_FIL_HLD_END_CNS_ERR l RTL_VOL_FIL_HLD_END_CNS_ERR High unsigned int - 0.00097656 1.0 0.0 - 22 - -
CDM2_FUELLMENGE_AKTIVTANK_ANFANG 0xD7DB STAT_CDM2_FUELLMENGE_AKTIVTANK_ANFANG_WERT RTL_VOL_FIL_HLD_ST_CNS_ERR l RTL_VOL_FIL_HLD_ST_CNS_ERR High unsigned int - 0.00097656 1.0 0.0 - 22 - -
TEMPERATUR_ABGAS_DOSIERVENTIL 0xD7DC STAT_TEMPERATUR_ABGAS_DOSIERVENTIL_WERT TEG_RAG_INJ_BK_1 °C TEG_RAG_INJ_BK_1 High signed int - 0.0625 1.0 0.0 - 22 - -
TEMPERATUR_DRUCKSENSOR_CROSSCHECK 0xD7DE STAT_TEMPERATUR_DRUCKSENSOR_CROSSCHECK_WERT TEMP_PRS_RAG_SENS_HLD_CRCH °C TEMP_PRS_RAG_SENS_HLD_CRCH High unsigned int - 0.0625 1.0 -273.15 - 22 - -
TEMPERATUR_LEVELSENSOR_AKTIVTANK_CROSSCHECK 0xD7DF STAT_TEMPERATUR_LEVELSENSOR_AKTIVTANK_CROSSCHECK_WERT TEMP_RAG_TANK_SENS_HLD_CRCH °C TEMP_RAG_TANK_SENS_HLD_CRCH High unsigned int - 0.0625 1.0 -273.15 - 22 - -
TEMPERATUR_DOSIERVENTIL_CROSSCHECK 0xD7EE STAT_TEMPERATUR_DOSIERVENTIL_CROSSCHECK_WERT TEMP_RDU_COIL_MES_HLD_CRCH °C TEMP_RDU_COIL_MES_HLD_CRCH High signed int - 0.0078125 1.0 0.0 - 22 - -
SYSTEMLECKAGE_DIAGNOSE 0xD7EF STAT_SYSTEMLECKAGE_DIAGNOSE_WERT VFL_RAG_LEAK_DIAG, [Mikroliter/Sekunde] - VFL_RAG_LEAK_DIAG High unsigned int - 0.03125 1.0 0.0 - 22 - -
SYSTEMLECKAGE_GEMESSEN 0xD810 STAT_SYSTEMLECKAGE_GEMESSEN_WERT VFL_LEAK_RAG_MES, [Mikroliter/Sekunde] - VFL_LEAK_RAG_MES High unsigned int - 0.03125 1.0 0.0 - 22 - -
VOLUMENSTROM_ANGEFORDERT 0xD812 STAT_VOLUMENSTROM_ANGEFORDERT_WERT VFL_RAG_PUMP_PCTL, [Mikroliter/Sekunde] - VFL_RAG_PUMP_CTL High unsigned int - 1.0 1.0 0.0 - 22 - -
CDM1_VERBRAUCH_IST_ZU_SOLL 0xD813 STAT_CDM1_VERBRAUCH_IST_ZU_SOLL_WERT VOL_PUMP_STK_DIF_CNS_ERR_PERC % VOL_PUMP_STK_DIF_CNS_ERR_PERC High signed int - 0.1 1.0 0.0 - 22 - -
DOSIERVENTIL_SPANNUNG_HIGH_SIDE 0xD814 STAT_DOSIERVENTIL_SPANNUNG_HIGH_SIDE_WERT VP_FB_RAG_INJ_H_SIDE V VP_FB_RAG_INJ_H_SIDE High unsigned int - 0.00015258 1.0 0.0 - 22 - -
DOSIERVENTIL_SPANNUNG_LOW_SIDE 0xD815 STAT_DOSIERVENTIL_SPANNUNG_LOW_SIDE_WERT VP_FB_RAG_INJ_L_SIDE V VP_FB_RAG_INJ_L_SIDE High unsigned int - 0.00015258 1.0 0.0 - 22 - -
SPANNUNG_KLEMME_30B_LOGIK 0xD816 STAT_SPANNUNG_KLEMME_30B_LOGIK_WERT VP_PWR[0] V VP_PWR[0] High signed int - 0.01953125 1.0 0.0 - 22 - -
SPANNUNG_KLEMME_30_HEIZER 0xD818 STAT_SPANNUNG_KLEMME_30_HEIZER_WERT VP_PWR[1] V VP_PWR[1] High signed int - 0.01953125 1.0 0.0 - 22 - -
SERIENNUMMER_VOLLSTAENDIG 0xD820 STAT_SERIENNUMMER_VOLLSTAENDIG_DATA DATA_MATRIX_CODE_PCB Vollständige eindeutige 16-stellige Seriennummer des SCR-Steuergeräts. DATA DATA_MATRIX_CODE_PCB High data[16] - 1.0 1.0 0.0 - 22 - -
CDM1_HIGH_FEHLER_BIS_UEBERGABE_CDM2 0xD821 STAT_CDM1_HIGH_FEHLER_BIS_UEBERGABE_CDM2_WERT CTR_RAG_CNS_H_RTL_MIL_REQ - CTR_RAG_CNS_H_RTL_MIL_REQ High unsigned char - 1.0 1.0 0.0 - 22 - -
CDM1_LOW_FEHLER_BIS_UEBERGABE_CDM2 0xD822 STAT_CDM1_LOW_FEHLER_BIS_UEBERGABE_CDM2_WERT CTR_RAG_CNS_L_RTL_MIL_REQ - CTR_RAG_CNS_L_RTL_MIL_REQ High unsigned char - 1.0 1.0 0.0 - 22 - -
CDM2_VERBRAUCH_SUMME 0xD823 STAT_CDM2_VERBRAUCH_SUMME_WERT RAG_VOL_INJ_SUM_INT_CNS_ERR µl RAG_VOL_INJ_SUM_INT_CNS_ERR High unsigned long - 0.00390625 1.0 0.0 - 22 - -
ZAEHLER_DC_RBM 0xD824 STAT_ZAEHLER_DC_RBM_WERT CTR_CDN_OBD_RBM - CTR_CDN_OBD_RBM High unsigned int - 1.0 1.0 0.0 - 22 - -
ZAEHLER_DC 0xD825 STAT_ZAEHLER_DC_WERT CTR_IGK_CYC_RBM - CTR_IGK_CYC_RBM High unsigned int - 1.0 1.0 0.0 - 22 - -
DRUCKSENSOR_DATEN_FAST_CHANNEL 0xD826 STAT_DRUCKSENSOR_DATEN_FAST_CHANNEL_WERT DATA_CHN_SENS_SENT[0][UREA_PRS] - DATA_CHN_SENS_SENT[0][UREA_PRS] High unsigned int - 1.0 1.0 0.0 - 22 - -
DRUCKSENSOR_FEHLER 0xD827 STAT_DRUCKSENSOR_FEHLER_WERT DATA_ERR_SRL_SENS_SENT[UREA_PRS] - DATA_ERR_SRL_SENS_SENT[UREA_PRS] High unsigned int - 1.0 1.0 0.0 - 22 - -
LECKAGE_FUELLSTANDSBASIERT_BITFELD 0xD828 STAT_LECKAGE_FUELLSTANDSBASIERT_BITFELD_WERT LF_RTL_CNS_LEAK_DIAG_ENA_CDN - LF_RTL_CNS_LEAK_DIAG_ENA_CDN High unsigned int - 1.0 1.0 0.0 - 22 - -
CDM3_DOSIERMENGENABWEICHUNG_RELATIV 0xD829 STAT_CDM3_DOSIERMENGENABWEICHUNG_RELATIV_WERT M_RAG_DIF_CNS_ERR_PERC % M_RAG_DIF_CNS_ERR_PERC High signed int - 0.1 1.0 0.0 - 22 - -
CDM3_DOSIERMENGE_IST_AUS_DRUCKSTUFEN 0xD82A STAT_CDM3_DOSIERMENGE_IST_AUS_DRUCKSTUFEN_WERT M_RAG_PRS_SUM_CNS_ERR_ENVD mg M_RAG_PRS_SUM_CNS_ERR_ENVD High unsigned int - 1.0 1.0 0.0 - 22 - -
CDM3_DOSIERMENGE_SOLL 0xD82B STAT_CDM_DOSIERMENGE_SOLL_WERT M_RAG_TAR_SUM_CNS_ERR_ENVD mg M_RAG_TAR_SUM_CNS_ERR_ENVD High unsigned int - 1.0 1.0 0.0 - 22 - -
SUMME_DRUCKSTUFEN_INJ_BLOCK 0xD82D STAT_SUMME_DRUCKSTUFEN_INJ_BLOCK_WERT PRS_DIF_SUM_INJ_BLOCK[0] bar PRS_DIF_SUM_INJ_BLOCK[0] High signed int - 0.00097656 1.0 0.0 - 22 - -
SUMME_DRUCKSTUFEN_PUMP_AIR 0xD82E STAT_SUMME_DRUCKSTUFEN_PUMP_AIR_WERT PRS_DIF_SUM_PUMP_AIR bar PRS_DIF_SUM_PUMP_AIR High signed int - 0.00097656 1.0 0.0 - 22 - -
CDM2_HIGH_RELATIV 0xD84E STAT_CDM2_HIGH_RELATIV_WERT RAG_CNS_H_RTL_PERC_SAE % RAG_CNS_H_RTL_PERC_SAE High signed int - 0.01 1.0 0.0 - 22 - -
CDM2_LOW_RELATIV 0xD84F STAT_CDM2_LOW_RELATIV_WERT RAG_CNS_L_RTL_PERC_SAE % RAG_CNS_L_RTL_PERC_SAE High signed int - 0.01 1.0 0.0 - 22 - -
LECKAGE_REFERENZ_DOSIERMENGE_INJEKTOR 0xD854 STAT_LECKAGE_REFERENZ_DOSIERMENGE_INJEKTOR_WERT RAG_INJ_CNS_WIN_SUM_LEAK_DIAG_ENVD l RAG_INJ_CNS_WIN_SUM_LEAK_DIAG_ENVD High unsigned int - 0.00048828 1.0 0.0 - 22 - -
CDM2_DOSIERMENGE_AUS_FUELLSTANDSAENDERUNG 0xD855 STAT_CDM2_DOSIERMENGE_AUS_FUELLSTANDSAENDERUNG_WERT RAG_VOL_DIF_SUM_CNS_ERR l RAG_VOL_DIF_SUM_CNS_ERR High signed int - 0.00097656 1.0 0.0 - 22 - -
LECKAGE_DOSIERMENGE_AUS_FUELLSTANDSAENDERUNG 0xD856 STAT_LECKAGE_DOSIERMENGE_AUS_FUELLSTANDSERFASSUNG_WERT RAG_VOL_DIF_WIN_SUM_LEAK_DIAG_ENVD l RAG_VOL_DIF_WIN_SUM_LEAK_DIAG_ENVD High unsigned int - 0.00048828 1.0 0.0 - 22 - -
CDM2_REFERENZ_DOSIERMENGE_INJEKTOR 0xD857 STAT_CDM2_REFERENZ_DOSIERMENGE_INJEKTOR_WERT RAG_VOL_INJ_SUM_CNS_ERR l RAG_VOL_INJ_SUM_CNS_ERR High unsigned int - 0.00097656 1.0 0.0 - 22 - -
CDM2_VOLUMEN_AUS_FUELLSTANDSAENDERUNG 0xD858 STAT_CDM2_VOLUMEN_AUS_FUELLSTANDSAENDERUNG_WERT RTL_DIF_SYM_FAST_CNS_ERR l RTL_DIF_SYM_FAST_CNS_ERR High signed int - 0.00097656 1.0 0.0 - 22 - -
SYSTEMSTEIFIGKEIT_BERECHNET 0xD8F6 STAT_SYSTEMSTEIFIGKEIT_BERECHNET_WERT STFN_RAG_SYS - STFN_RAG_SYS High unsigned int - 0.00012207 1.0 0.0 - 22 - -
SYSTEM_LECKAGE_ADAPTIERT 0xD8F7 STAT_SYSTEM_LECKAGE_ADAPTIERT_WERT VFL_LEAK_RAG_AD - VFL_LEAK_RAG_AD High unsigned int - 0.03125 1.0 0.0 - 22 - -
SYSTEM_LECKAGE_CDM1 0xD8F8 STAT_SYSTEM_LECKAGE_CDM1_WERT VFL_RAG_LEAK_CNS_ERR - VFL_RAG_LEAK_CNS_ERR High unsigned int - 0.03125 1.0 0.0 - 22 - -
CDM1_VOLUMEN_AUS_DOSIERANFORDERUNG 0xD8F9 STAT_CDM1_VOLUMEN_AUS_DOSIERANFORDERUNG_WERT VOL_DIF_SYM_FAST_CNS_ERR l VOL_DIF_SYM_FAST_CNS_ERR High unsigned int - 0.00097656 1.0 0.0 - 22 - -
CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_GEFILTERT_2 0xD8FA STAT_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_GEFILTERT_2_WERT VOL_PUMP_STK_FIL_CNS_ERR µl VOL_PUMP_STK_FIL_CNS_ERR High unsigned int - 0.1 1.0 0.0 - 22 - -
CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_ERSTER_2 0xD8FB STAT_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_ERSTER_2_WERT VOL_PUMP_STK_FIRST_CNS_ERR µl VOL_PUMP_STK_FIRST_CNS_ERR High unsigned int - 0.1 1.0 0.0 - 22 - -
CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_REFERENZ_2 0xD8FC STAT_CDM1_VOLUMEN_FOERDERPUMPE_LERNWERT_REFERENZ_2_WERT VOL_PUMP_STK_REF_CNS_ERR µl VOL_PUMP_STK_REF_CNS_ERR High unsigned int - 0.1 1.0 0.0 - 22 - -
GESAMTDOSIERMENGE_AKTUELLER_DC_TANK_GEFROREN 0xE38B STAT_GESAMTDOSIERMENGE_AKTUELLER_DC_TANK_GEFROREN_WERT Gen3: M_RAG_CNS_DC_TOT_ENVD Gen4: M_RAG_CNS_DC_TOT mg M_RAG_CNS_DC_TOT_ENVD High unsigned int - 16.0 1.0 0.0 - 22 - -
AKTIVTANKHEIZUNG_LEISTUNG_SETPOINT 0xE38C STAT_AKTIVTANKHEIZUNG_LEISTUNG_SETPOINT_WERT POW_RAG_HEAT_TANK_SEL_SP W POW_RAG_HEAT_TANK_SEL_SP High unsigned int - 0.1 1.0 0.0 - 22 - -
DOSIERLEITUNGSHEIZUNG_LEISTUNG_SETPOINT 0xE38D STAT_DOSIERLEITUNGSHEIZUNG_LEISTUNG_SETPOINT_WERT POW_RAG_HEAT_TUBE_SEL_SP W POW_RAG_HEAT_TUBE_SEL_SP High unsigned int - 0.1 1.0 0.0 - 22 - -
ACTIVE_DIAGNOSTIC_SESSION 0xF186 STAT_ACTIVE_DIAGNOSTIC_SESSION activeDiagnosticSession 0-n - High unsigned char RDBI_ADS_DOP - - - - 22 - -

STATUS_FUELLSTAND_GEBER_SCR_ADDITIV

Dimensions: 3 rows × 2 columns

WERT TEXT
0x0 unter Restriction Level
0x1 über Restriction Level
0x3 Signal ungültig

STATUS_FUELLSTAND_NIVEAU_SCR_ADDITIV

Dimensions: 7 rows × 2 columns

WERT TEXT
0x0 Leer
0x1 Begrenzung
0x2 Warnung
0x3 OK
0x4 Voll
0x7 Signal ungültig
0xFF Wert ungültig

STATUS_INITIALISIERUNG_FILTER_WERT_DME

Dimensions: 4 rows × 2 columns

WERT TEXT
0x0 CT1 Filterwert nicht initialisiert
0x1 CT1 Filterwert wurde initialisiert
0x3 Signal ungültig
0xFF Wert ungültig

STATUS_INITIALISIERUNG_FILTER_WERT_SCR_ADDITIV

Dimensions: 3 rows × 2 columns

WERT TEXT
0x0 CT1 Filterwert nicht initialisiert
0x1 CT1 Filterwert wurde initialisiert
0x3 Signal ungültig

STATUS_KLEMME

Dimensions: 3 rows × 2 columns

WERT TEXT
0x00 Klemme 15 aus
0x01 Klemme 15 an
0xFF Wert ungültig

STATUS_NACHTANKEN_SCR_ADDITIV

Dimensions: 3 rows × 2 columns

WERT TEXT
0x0 Keine Nachbetankung
0x1 Nachbetankung erkannt
0x3 Signal ungültig

STATUS_RAM_DATEN_SCHREIBEN_TAB

Dimensions: 4 rows × 2 columns

WERT TEXT
0x00 Schreiben erfolgreich
0x01 Schreiben fehlgeschlagen
0x02 Schreiben läuft
0x03 Schreiben noch nicht angestoßen (Routine nicht gestartet)

STATUS_SPERRE_FEHLERSPEICHER_FZM

Dimensions: 3 rows × 2 columns

WERT TEXT
0x0000 Fehlerspeichersperre aktiv
0x0001 Fehlerspeichersperre nicht aktiv
0xFFFF Wert ungültig

STATUS_VERSORGUNGSSPANNUNG

Dimensions: 5 rows × 2 columns

WERT TEXT
0x0000 Versorgungsspannung im Bereich
0x0400 Versorgungsspannung zu hoch
0x0800 Versorgungsspannung zu niedrig
0x0C00 Signal nicht erkannt
0xFFFF Wert ungültig

STATUS_ZUSTAND_FAHRZEUG

Dimensions: 17 rows × 2 columns

WERT TEXT
0x0 keine Kommunikation
0x1 Parken_BN_niO
0x2 Parken_BN_iO
0x3 Standfunktionen_Kunde_nicht_im_FZG
0x4 keine Kommunikation
0x5 Wohnen
0x6 keine Kommunikation
0x7 Pruefen_Analyse_Diagnose
0x8 Fahrbereitschaft_herstellen
0x9 keine Kommunikation
0xA Fahren
0xB keine Kommunikation
0xC Fahrbereitschaft_beenden
0xD keine Kommunikation
0xE keine Kommunikation
0xF Signal_unbefuellt
0xFF Wert ungültig

TAB_CAN_RX_STATUS_MOTOR_AUS_ZEIT

Dimensions: 4 rows × 2 columns

WERT TEXT
0x00 Wert gültig
0x01 Fehler und Ersatzwert
0x03 Abstellzeit nicht verfügbar
0xFF Wert ungültig

TAB_CAN_TX_STATUS_IST_QUALITAET_SCR_ADDITIV

Dimensions: 4 rows × 2 columns

WERT TEXT
0x0000 Wert gültig
0x0001 Messung ungültig und Ersatzwert
0x0002 Sensorfehler und Ersatzwert
0xFFFF Wert ungültig

TAB_DOSIERMENGENTEST_DETAIL

Dimensions: 26 rows × 2 columns

WERT TEXT
0x0 Funktion noch nicht gestartet
0x1 System in Vorbereitung
0x2 Funktion kann wegen Fehlerspeichereintrag / FID nicht gestartet werden
0x3 Funktion läuft
0x4 Startbedingung nicht erfüllt: Eindosierung nicht erlaubt
0x5 Freigabe für Eindosierung nicht mehr vorhanden
0x6 Funktion vollständig und fehlerfrei durchlaufen
0x7 Funktion fehlerhaft beendet
0x8 frei
0x9 frei
0xF0 frei
0xF1 System hinter Förderpumpe nicht befüllt
0xF2 Auftauen erforderlich oder Dosierleitung nicht entleert
0xF3 Rücksaugen aktiv
0xF4 Hohe Abgastemperatur
0xF5 Auftauen erforderlich
0xF6 Erneutes Heizen erforderlich
0xF7 Fahrzeug in Bewegung
0xF8 Umgebungslufttemperatur nicht OK
0xF9 Aktivtanktemperatur nicht OK
0xFA Aktivtankfüllstand nicht OK
0xFB Berechnete Aktivtankfüllmenge nicht OK
0xFC Batteriespannung nicht OK
0xFD Zündung aus
0xFE Verbrennungsmotor läuft
0xFF Verbrennungsmotor läuft nicht

TAB_DRUCKAUFBAU_DETAIL

Dimensions: 26 rows × 2 columns

WERT TEXT
0x0 Funktion noch nicht gestartet
0x1 System in Vorbereitung
0x2 Funktion kann wegen Fehlerspeichereintrag / FID nicht gestartet werden
0x3 Funktion läuft
0x4 Startbedingung nicht erfüllt: Druckaufbau kann nur begrenzt erfolgen
0x5 Freigabe für Druckaufbau nicht mehr vorhanden
0x6 Funktion vollständig und fehlerfrei durchlaufen
0x7 frei
0x8 Funktion vollständig, aber zu langsam durchlaufen
0x9 Funktion vollständig, aber zu schnell durchlaufen
0xF0 frei
0xF1 System hinter Förderpumpe nicht befüllt
0xF2 Auftauen erforderlich oder Dosierleitung nicht entleert
0xF3 Rücksaugen aktiv
0xF4 Hohe Abgastemperatur
0xF5 Auftauen erforderlich
0xF6 Erneutes Heizen erforderlich
0xF7 Fahrzeug in Bewegung
0xF8 Umgebungslufttemperatur nicht OK
0xF9 Aktivtanktemperatur nicht OK
0xFA Aktivtankfüllstand nicht OK
0xFB Berechnete Aktivtankfüllmenge nicht OK
0xFC Batteriespannung nicht OK
0xFD Zündung aus
0xFE Verbrennungsmotor läuft
0xFF Verbrennungsmotor läuft nicht

TAB_HEIZUNG_DETAIL

Dimensions: 26 rows × 2 columns

WERT TEXT
0x0 Funktion noch nicht gestartet
0x1 System in Vorbereitung
0x2 Funktion kann wegen Fehlerspeichereintrag / FID nicht gestartet werden
0x3 Funktion läuft
0x4 Startbedingung nicht erfüllt: Heizerschutz aktiv
0x5 frei
0x6 Funktion vollständig und fehlerfrei durchlaufen
0x7 Funktion fehlerhaft beendet
0x8 Funktion vollständig, aber zu langsam durchlaufen
0x9 Funktion vollständig, aber zu schnell durchlaufen
0xF0 frei
0xF1 System hinter Förderpumpe nicht befüllt
0xF2 Auftauen erforderlich oder Dosierleitung nicht entleert
0xF3 Rücksaugen aktiv
0xF4 Hohe Abgastemperatur
0xF5 Auftauen erforderlich
0xF6 Erneutes Heizen erforderlich
0xF7 Fahrzeug in Bewegung
0xF8 Umgebungslufttemperatur nicht OK
0xF9 Aktivtanktemperatur nicht OK
0xFA Aktivtankfüllstand nicht OK
0xFB Berechnete Aktivtankfüllmenge nicht OK
0xFC Batteriespannung nicht OK
0xFD Zündung aus
0xFE Verbrennungsmotor läuft
0xFF Verbrennungsmotor läuft nicht

TAB_LECKAGEERKENNUNG_DETAIL

Dimensions: 26 rows × 2 columns

WERT TEXT
0x0 Funktion noch nicht gestartet
0x1 System in Vorbereitung
0x2 Funktion kann wegen Fehlerspeichereintrag / FID nicht gestartet werden
0x3 Funktion läuft
0x4 Startbedingung nicht erfüllt: Druckaufbau nicht erfolgt.
0x5 frei
0x6 Funktion vollständig und fehlerfrei durchlaufen
0x7 Funktion fehlerhaft beendet
0x8 frei
0x9 frei
0xF0 frei
0xF1 System hinter Förderpumpe nicht befüllt
0xF2 Auftauen erforderlich oder Dosierleitung nicht entleert
0xF3 Rücksaugen aktiv
0xF4 Hohe Abgastemperatur
0xF5 Auftauen erforderlich
0xF6 Erneutes Heizen erforderlich
0xF7 Fahrzeug in Bewegung
0xF8 Umgebungslufttemperatur nicht OK
0xF9 Aktivtanktemperatur nicht OK
0xFA Aktivtankfüllstand nicht OK
0xFB Berechnete Aktivtankfüllmenge nicht OK
0xFC Batteriespannung nicht OK
0xFD Zündung aus
0xFE Verbrennungsmotor läuft
0xFF Verbrennungsmotor läuft nicht

TAB_RUECKSAUGEN_DETAIL

Dimensions: 26 rows × 2 columns

WERT TEXT
0x0 Funktion noch nicht gestartet
0x1 System in Vorbereitung
0x2 Funktion kann wegen Fehlerspeichereintrag / FID nicht gestartet werden
0x3 Funktion läuft
0x4 Startbedingung nicht erfüllt: Druckaufbau nicht OK, Systemdruck zu niedrig
0x5 frei
0x6 Funktion vollständig und fehlerfrei durchlaufen
0x7 frei
0x8 Funktion vollständig, aber zu langsam durchlaufen
0x9 Funktion vollständig, aber zu schnell durchlaufen
0xF0 frei
0xF1 System hinter Förderpumpe nicht befüllt
0xF2 Auftauen erforderlich oder Dosierleitung nicht entleert
0xF3 Rücksaugen aktiv
0xF4 Hohe Abgastemperatur
0xF5 Auftauen erforderlich
0xF6 Erneutes Heizen erforderlich
0xF7 Fahrzeug in Bewegung
0xF8 Umgebungslufttemperatur nicht OK
0xF9 Aktivtanktemperatur nicht OK
0xFA Aktivtankfüllstand nicht OK
0xFB Berechnete Aktivtankfüllmenge nicht OK
0xFC Batteriespannung nicht OK
0xFD Zündung aus
0xFE Verbrennungsmotor läuft
0xFF Verbrennungsmotor läuft nicht

TAB_STATE_DEAKTIVIERUNG_SCHUTZDOSIERUNG

Dimensions: 3 rows × 2 columns

WERT TEXT
0x00 Schutzdosierung aktiv
0x01 Schutzdosierung deaktiviert
0xFF Wert ungültig

TAB_STATE_MONTAGEMODUS

Dimensions: 3 rows × 2 columns

WERT TEXT
0x0 Montagemodus nicht aktiv
0x1 Montagemodus aktiv
0xFF Wert ungültig

TAB_STATE_ROUTINE

Dimensions: 9 rows × 2 columns

WERT TEXT
0x0 Routine noch nicht gestartet
0x1 Start-/Ansteuerbedingung nicht erfüllt
0x2 Parameter ungültig
0x3 Warten auf Freigabe
0x5 Routine läuft
0x7 Routine abgebrochen (kein Zyklusflag/ Readiness gesetzt)
0x8 Routine vollständig durchlaufen und kein Fehler erkannt
0x9 Routine vollständig durchlaufen und Fehler erkannt.
0xFF Wert ungültig

TAB_TRANSFERPUMPE_DETAIL

Dimensions: 26 rows × 2 columns

WERT TEXT
0x0 Funktion noch nicht gestartet
0x1 System in Vorbereitung
0x2 Funktion kann wegen Fehlerspeichereintrag / FID nicht gestartet werden
0x3 Funktion läuft
0x4 Startbedingung nicht erfüllt: Füllstandssignal ungültig
0x5 Aktivtank voll / Passivtank leer
0x6 Funktion vollständig und fehlerfrei durchlaufen
0x7 Funktion fehlerhaft beendet
0x8 Funktion vollständig, aber zu langsam durchlaufen
0x9 Funktion vollständig, aber zu schnell durchlaufen
0xF0 frei
0xF1 System hinter Förderpumpe nicht befüllt
0xF2 Auftauen erforderlich oder Dosierleitung nicht entleert
0xF3 Rücksaugen aktiv
0xF4 Hohe Abgastemperatur
0xF5 Auftauen erforderlich
0xF6 Erneutes Heizen erforderlich
0xF7 Fahrzeug in Bewegung
0xF8 Umgebungslufttemperatur nicht OK
0xF9 Aktivtanktemperatur nicht OK
0xFA Aktivtankfüllstand nicht OK
0xFB Berechnete Aktivtankfüllmenge nicht OK
0xFC Batteriespannung nicht OK
0xFD Zündung aus
0xFE Verbrennungsmotor läuft
0xFF Verbrennungsmotor läuft nicht

TAB_TROCKENTAKTUNG_DETAIL

Dimensions: 26 rows × 2 columns

WERT TEXT
0x0 Funktion noch nicht gestartet
0x1 System in Vorbereitung
0x2 Funktion kann wegen Fehlerspeichereintrag / FID nicht gestartet werden
0x3 Funktion läuft
0x4 Startbedingung nicht erfüllt: Systemdruck zu hoch
0x5 Unerwartete Änderung des Systemdrucks oder der Bedingungen für Öffnen des Dosierventils
0x6 Funktion vollständig und fehlerfrei durchlaufen
0x7 Funktion fehlerhaft beendet
0x8 frei
0x9 frei
0xF0 frei
0xF1 System hinter Förderpumpe nicht befüllt
0xF2 Auftauen erforderlich oder Dosierleitung nicht entleert
0xF3 Rücksaugen aktiv
0xF4 Hohe Abgastemperatur
0xF5 Auftauen erforderlich
0xF6 Erneutes Heizen erforderlich
0xF7 Fahrzeug in Bewegung
0xF8 Umgebungslufttemperatur nicht OK
0xF9 Aktivtanktemperatur nicht OK
0xFA Aktivtankfüllstand nicht OK
0xFB Berechnete Aktivtankfüllmenge nicht OK
0xFC Batteriespannung nicht OK
0xFD Zündung aus
0xFE Verbrennungsmotor läuft
0xFF Verbrennungsmotor läuft nicht

TEMPERATURBEREICH

Dimensions: 5 rows × 2 columns

WERT TEXT
0x0000 Temperatur innerhalb der Grenzen
0x0100 Temperatur zu hoch
0x0200 Temperatur zu niedrig
0x0300 Signal nicht erkannt
0xFFFF Wert ungültig

VERBRAUCHER_KLASSE_FEPM

Dimensions: 5 rows × 2 columns

WERT TEXT
0x1 Klasse 1
0x2 Klasse 2
0x3 Klasse 3
0x4 Klasse 4
0x7 Signal ungültig

VERBRENNUNGSMOTOR

Dimensions: 13 rows × 2 columns

WERT TEXT
0x00 Verbrennungsmotor steht durch Fahrerwunsch.
0x01 Verbrennungsmotor startet durch Fahrerwunsch.
0x02 Verbrennungsmotor läuft.
0x04 Startankündigung des Verbrennungsmotors durch Fahrerwunsch
0x06 Stoppankündigung des Verbrennungsmotors durch Fahrerwunsch.
0x08 Verbrennungsmotor steht durch MSA-Anforderung.
0x09 Verbrennungsmotor startet durch MSA-Anforderung.
0x0C Startankündigung des Verbrennungsmotors durch MSA-Anforderung.
0x0D Stoppankündigung des Verbrennungsmotors durch MSA-Anforderung.
0x12 Verbrennungsmotor im Auslauf durch Fahrerwunsch.
0x1A Verbrennungsmotor im Auslauf durch MSA-Anforderung.
0x1D Verbrennungsmotor im Auslauf mit Startankündigung durch MSA-Anforderung.
0xFF Wert ungültig