SRR01_VR.prg
INFO
| Field |
Value |
| ECU |
Short Range Radar vorne rechts |
| ORIGIN |
BMW EF-631 Nüdling |
| REVISION |
2.000 |
| AUTHOR |
BMW EV-313 Tschoepe |
| COMMENT |
- |
| PACKAGE |
1.989 |
| SPRACHE |
deutsch |
Jobs
Index
- INFO - Information SGBD
- INITIALISIERUNG - Initialisierung und Kommunikationsparameter
- IDENT - Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
- FS_LESEN - Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
- FS_LESEN_DETAIL - Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
- FS_LOESCHEN - Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
- PRUEFSTEMPEL_LESEN - Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
- PRUEFSTEMPEL_SCHREIBEN - Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
- SVK_LESEN - Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
- STATUS_LESEN - Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
- STEUERN - Vorgeben eines Status UDS : $2E WriteDataByIdentifier
- SERIENNUMMER_LESEN - Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
- STEUERN_ROUTINE - Vorgeben eines Status UDS : $31 RoutineControl
- FS_SPERREN - Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
- IS_LESEN - Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $17 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
- IS_LESEN_DETAIL - sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $19 ReadDTCInformation UDS : $18 reportDTCSnapshotRecordByDTCNumber UDS : $19 reportDTCExtendedDataRecordByDTCNumber UDS : $-- reportSeverityInformationOfDTC (nicht möglich!) Modus: Default
- IS_LOESCHEN - Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default
- HERSTELLINFO_LESEN - Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
- DIAGNOSE_AUFRECHT - Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
- DIAGNOSE_MODE - SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
- ENERGIESPARMODE - Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
- STATUS_ENERGIESPARMODE - Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
- STATUS_BETRIEBSMODE - Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default
- STEUERN_BETRIEBSMODE - Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default
- STEUERGERAETE_RESET - Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
- STATUS_ROE_REPORT - Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS: $86 ResponseOnEvent $04 report activated events $02 eventWindowTime - infinite (LH Diagnosemaster V11 oder höher, Umsetzung nach LH V6 - V10 wird jedoch toleriert)
- STEUERN_ROE_PERSISTENT_STOP - Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
- STEUERN_ROE_PERSISTENT_START - Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
- CPS_LESEN - Codierpruefstempel lesen UDS : $22 ReadDataByIdentifier UDS : $37FE DataIdentifier Codierpruefstempel Modus: Default
INFO
Information SGBD
No arguments.
Results
| Name |
Type |
Comment |
| ECU |
string |
Steuergerät im Klartext |
| ORIGIN |
string |
Steuergeräte-Verantwortlicher |
| REVISION |
string |
Versions-Nummer |
| AUTHOR |
string |
Namen aller Autoren |
| COMMENT |
string |
wichtige Hinweise |
| PACKAGE |
string |
Include-Paket-Nummer |
| SPRACHE |
string |
deutsch, english |
INITIALISIERUNG
Initialisierung und Kommunikationsparameter
No arguments.
Results
| Name |
Type |
Comment |
| DONE |
int |
1, wenn Okay |
IDENT
Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| ID_SG_ADR |
long |
Steuergeraeteadresse |
| ID_SGBD_INDEX |
long |
Index zur Erkennung der SG-Variante |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
FS_LESEN
Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
Arguments
| Name |
Type |
Comment |
| FEHLER_KLASSE |
string |
'IGNORIERE_EREIGNIS_DTC': Wenn EREIGNIS_DTC = '1', DTC-Fehlereinträge werden ignoriert sonst: FEHLERKLASSE wird ausgewertet |
Results
| Name |
Type |
Comment |
| F_VERSION |
int |
Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE |
binary |
Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR |
long |
Index fuer Fehlerort |
| F_ORT_TEXT |
string |
Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC |
int |
0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC -1: wird nicht unterstuetzt table FOrtTexte EREIGNIS_DTC |
| F_FEHLERKLASSE |
unsigned long |
table FOrtTexte FEHLERKLASSE |
| F_STATUSBYTE |
int |
Wert des DTC-Statusbyte laut ISO 14229 (bitcodiert) Bedeutung der einzelnen Bits: Bit 7: warningIndicatorRequested Bit 6: testNotCompletedThisOperationCycle Bit 5: testFailedSinceLastClear Bit 4: testNotCompletedSinceLastClear Bit 3: ConfirmedDTC Bit 2: PendingDTC Bit 1: testFailedThisOperationCycle Bit 0: testFailed |
| F_READY_NR |
int |
Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT |
string |
Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR |
int |
Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT |
string |
Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR |
int |
Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT |
string |
Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
FS_LESEN_DETAIL
Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
Arguments
| Name |
Type |
Comment |
| F_CODE |
long |
gewaehlter Fehlercode |
Results
| Name |
Type |
Comment |
| F_VERSION |
int |
Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE |
binary |
Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR |
long |
Index fuer Fehlerort |
| F_ORT_TEXT |
string |
Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC |
int |
0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_STATUSBYTE |
int |
Wert des DTC-Statusbyte laut ISO 14229 (bitcodiert) Bedeutung der einzelnen Bits: Bit 7: warningIndicatorRequested Bit 6: testNotCompletedThisOperationCycle Bit 5: testFailedSinceLastClear Bit 4: testNotCompletedSinceLastClear Bit 3: ConfirmedDTC Bit 2: PendingDTC Bit 1: testFailedThisOperationCycle Bit 0: testFailed |
| F_READY_NR |
int |
Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT |
string |
Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR |
int |
Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT |
string |
Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR |
int |
Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT |
string |
Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_HFK |
int |
Haeufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf |
| F_HLZ |
int |
Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Heilungsszaehler |
| F_UEBERLAUF |
int |
0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers |
| F_FEHLERKLASSE_NR |
int |
0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich ! |
| F_FEHLERKLASSE_TEXT |
string |
Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT |
| F_UW_ANZ |
int |
Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung |
| F_UW_KM |
long |
Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht |
| F_UW_KM_SUPREME |
string |
Umweltbedingung Kilometerstand metergenau (31 Bit) Wertebereich: 0 - 16777215 km |
| F_UW_KM_SUPREME_INSYNC |
unsigned char |
Environmental condition mileage (long, LSb 1 Bit) 0 == out of sync, 1 == insync |
| F_UW_ZEIT |
long |
Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_UW_ZEIT_MS |
int |
Umweltbedingung Zeit Millisekundenanteil Genauigkeit: in 5ms-Schritten -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_UW_ZEIT_SUPREME |
string |
Umweltbedingung Absolute Zeit mit Sekundenbruchteilen Genauigkeit: in 5ms-Schritten wenn Zeit nicht zur Verfuegung steht "No time received" |
| F_UW_ZEIT_SUPREME_INSYNC |
unsigned char |
Environmental condition system time (Bit0) 0 == out of sync, 1 == insync |
| F_UW_ZEIT_SUPREME_SYNCMETHOD |
unsigned char |
Environmental condition system time (Bit1 und Bit2) 00 == Kombizeit, 01 == DMCS, 10 == IEEE802.1AS, 11 == invalid |
| F_UW_ZEIT_SUPREME_SYNCMETHOD_INFO |
string |
Environmental condition system time (Bit1 und Bit2) table: 0 == Kombizeit, 1 == DMCS, 2 == IEEE802.1AS, 3 == invalid |
| F_UW_ZEIT_SUPREME_USER_INFORMATION |
string |
Environmental condition system time (Bit0, Bit1 und Bit2) TAB_ZEIT_USER_INFO |
| F_UW_BN |
int |
Umweltbedingung Basisnetz (1 Byte) -1, wenn Daten bzgl. Basisnetz nicht zur Verfuegung stehen |
| F_UW_TN |
long |
Umweltbedingung Teilnetz (3 Byte) -1, wenn Daten bzgl. funktionalem Teilnetz nicht zur Verfuegung stehen |
| F_SAE_CODE |
unsigned int |
Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD |
| F_SAE_CODE_STRING |
string |
5 stelliger Text in der Form 'Sxxxx' |
| F_SAE_CODE_TEXT |
string |
Text zu F_SAE_CODE |
| _RESPONSE_SNAPSHOT |
binary |
Hex-Antwort von SG |
| _RESPONSE_EXTENDED_DATA |
binary |
Hex-Antwort von SG |
| _RESPONSE_SEVERITY |
binary |
Hex-Antwort von SG |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
FS_LOESCHEN
Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
Arguments
| Name |
Type |
Comment |
| F_CODE |
long |
0x??????: Angabe eines einzelnen Fehlers Default: 0xFFFFFF: alle Fehler |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
PRUEFSTEMPEL_LESEN
Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| BYTE1 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE2 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE3 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
PRUEFSTEMPEL_SCHREIBEN
Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
Arguments
| Name |
Type |
Comment |
| BYTE1 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE2 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE3 |
int |
Bereich: 0-255 bzw. 0x00-0xFF |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
SVK_LESEN
Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
Arguments
| Name |
Type |
Comment |
| SVK |
string |
table SVK_ID BEZEICHNUNG WERT default SVK_AKTUELL |
Results
| Name |
Type |
Comment |
| PROG_TEST |
int |
Programmierabhaengigkeiten (ProgrammingDependenciesChecked) 1: IO : Signaturpruefung und ProgrammingDependenciesCheck erfolgreich 2: NIO: mindestens eine SWE fehlerhaft oder ProgrammingDependenciesCheck nicht durchgefuehrt 3: NIO: mindestens eine SWE passt nicht mit einer HWE zusammen 4: NIO: mindestens eine SWE passt nicht mit einer anderen SWE zusammen sonst: reserviert |
| ANZAHL_EINHEITEN |
int |
Anzahl der xWEn |
| PROG_DATUM |
string |
Programmierdatum (DD.MM.YY) |
| PROG_KM |
long |
KM-Stand bei Programmierung (10 KM bis 655350 KM) Inkrement sind 10 KM -1: KM-Stand wird nicht unterstuetzt |
| PROZESSKLASSE_WERT |
int |
table Prozessklassen WERT dezimale Angabe der Prozessklasse |
| PROZESSKLASSE_TEXT |
string |
table Prozessklassen BEZEICHNUNG Text-Angabe der Prozessklasse |
| PROZESSKLASSE_KURZTEXT |
string |
table Prozessklassen PROZESSKLASSE Text-Angabe des Prozessklassenkurztextes |
| SGBM_IDENTIFIER |
string |
Angabe SGBM-ID der Prozessklasse |
| VERSION |
string |
Angabe der Version der Prozessklasse |
| SGBM_ID |
string |
Angabe von Prozessklasse, SGBM-Identifier, Version |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STATUS_LESEN
Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
Arguments
| Name |
Type |
Comment |
| ARGUMENT_SPALTE |
string |
'ARG', 'ID', 'LABEL' |
| STATUS |
string |
Es muss mindestens ein Argument übergeben werden Es wird das zugehörige result erzeugt table SG_Funktionen ARG ID RESULTNAME RES_TABELLE ARG_TABELLE |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Antwort von SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN
Vorgeben eines Status UDS : $2E WriteDataByIdentifier
Arguments
| Name |
Type |
Comment |
| ARGUMENT_SPALTE |
string |
'ARG', 'ID', 'LABEL' |
| STATUS |
string |
Siehe table SG_Funktionen ARG ID LABEL ARG_TABELLE |
| WERT |
string |
Es muss mindestens ein Argument übergeben werden Argumente siehe table SG_Funktionen ARG ID ARG_TABELLE |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Antwort von SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
SERIENNUMMER_LESEN
Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| SERIENNUMMER |
string |
Seriennummer des Steuergeraets |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN_ROUTINE
Vorgeben eines Status UDS : $31 RoutineControl
Arguments
| Name |
Type |
Comment |
| ARGUMENT_SPALTE |
string |
'ARG', 'ID', 'LABEL' |
| STATUS |
string |
Siehe table SG_Funktionen ARG ID RES_TABELLE ARG_TABELLE |
| STEUERPARAMETER |
string |
'STR' = startRoutine 'STPR' = stopRoutine 'RRR' = requestRoutineResults |
| WERT |
string |
Argumente siehe table SG_Funktionen ARG_TABELLE |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Antwort von SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
FS_SPERREN
Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
Arguments
| Name |
Type |
Comment |
| SPERREN |
string |
"ja" -> Fehlerspeicher sperren "nein" -> Fehlerspeicher freigeben table DigitalArgument TEXT Default: "ja" |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
IS_LESEN
Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $17 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
Arguments
| Name |
Type |
Comment |
| IGNORIERE_EREIGNIS_DTC |
string |
'IGNORIERE_EREIGNIS_DTC': Alle Ereignis DTC-Fehlereinträge werden ignoriert sonst: alle Fehlereinträge werden ausgegeben |
Results
| Name |
Type |
Comment |
| F_VERSION |
int |
Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE |
binary |
Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR |
long |
Index fuer Fehlerort |
| F_ORT_TEXT |
string |
Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC |
int |
0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_STATUSBYTE |
int |
Wert des DTC-Statusbyte laut ISO 14229 (bitcodiert) Bedeutung der einzelnen Bits: Bit 7: warningIndicatorRequested Bit 6: testNotCompletedThisOperationCycle Bit 5: testFailedSinceLastClear Bit 4: testNotCompletedSinceLastClear Bit 3: ConfirmedDTC Bit 2: PendingDTC Bit 1: testFailedThisOperationCycle Bit 0: testFailed |
| F_READY_NR |
int |
Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT |
string |
Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR |
int |
Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT |
string |
Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR |
int |
Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT |
string |
Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
IS_LESEN_DETAIL
sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $19 ReadDTCInformation UDS : $18 reportDTCSnapshotRecordByDTCNumber UDS : $19 reportDTCExtendedDataRecordByDTCNumber UDS : $-- reportSeverityInformationOfDTC (nicht möglich!) Modus: Default
Arguments
| Name |
Type |
Comment |
| F_CODE |
long |
gewaehlter Infocode |
Results
| Name |
Type |
Comment |
| F_VERSION |
int |
Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE |
binary |
Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR |
long |
Index fuer Fehlerort |
| F_ORT_TEXT |
string |
Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC |
int |
0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_STATUSBYTE |
int |
Wert des DTC-Statusbyte laut ISO 14229 (bitcodiert) Bedeutung der einzelnen Bits: Bit 7: warningIndicatorRequested Bit 6: testNotCompletedThisOperationCycle Bit 5: testFailedSinceLastClear Bit 4: testNotCompletedSinceLastClear Bit 3: ConfirmedDTC Bit 2: PendingDTC Bit 1: testFailedThisOperationCycle Bit 0: testFailed |
| F_READY_NR |
int |
Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT |
string |
Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR |
int |
Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT |
string |
Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR |
int |
Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT |
string |
Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_HFK |
int |
Haeufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf |
| F_HLZ |
int |
Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Heilungsszaehler |
| F_UEBERLAUF |
int |
0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers |
| F_FEHLERKLASSE_NR |
int |
0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich ! |
| F_FEHLERKLASSE_TEXT |
string |
Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT |
| F_UW_ANZ |
int |
Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung |
| F_UW_KM |
long |
Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht |
| F_UW_KM_SUPREME |
string |
Umweltbedingung Kilometerstand metergenau (31 Bit) Wertebereich: 0 - 16777215 km |
| F_UW_KM_SUPREME_INSYNC |
unsigned char |
Environmental condition mileage (long, LSb 1 Bit) 0 == out of sync, 1 == insync |
| F_UW_ZEIT |
long |
Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_UW_ZEIT_MS |
int |
Umweltbedingung Zeit Millisekundenanteil Genauigkeit: in 5ms-Schritten -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_UW_ZEIT_SUPREME |
string |
Umweltbedingung Absolute Zeit mit Sekundenbruchteilen Genauigkeit: in 5ms-Schritten wenn Zeit nicht zur Verfuegung steht "No time received" |
| F_UW_ZEIT_SUPREME_INSYNC |
unsigned char |
Environmental condition system time (Bit0) 0 == out of sync, 1 == insync |
| F_UW_ZEIT_SUPREME_SYNCMETHOD |
unsigned char |
Environmental condition system time (Bit1 und Bit2) 00 == Kombizeit, 01 == DMCS, 10 == IEEE802.1AS, 11 == invalid |
| F_UW_ZEIT_SUPREME_SYNCMETHOD_INFO |
string |
Environmental condition system time (Bit1 und Bit2) table: 0 == Kombizeit, 1 == DMCS, 2 == IEEE802.1AS, 3 == invalid |
| F_UW_ZEIT_SUPREME_USER_INFORMATION |
string |
Environmental condition system time (Bit0, Bit1 und Bit2) TAB_ZEIT_USER_INFO |
| F_UW_BN |
int |
Umweltbedingung Basisnetz (1 Byte) -1, wenn Daten bzgl. Basisnetz nicht zur Verfuegung stehen |
| F_UW_TN |
long |
Umweltbedingung Teilnetz (3 Byte) -1, wenn Daten bzgl. funktionalem Teilnetz nicht zur Verfuegung stehen |
| F_SAE_CODE |
unsigned int |
Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD |
| F_SAE_CODE_STRING |
string |
5 stelliger Text in der Form 'Sxxxx' |
| F_SAE_CODE_TEXT |
string |
Text zu F_SAE_CODE |
| _RESPONSE_SNAPSHOT |
binary |
Hex-Antwort von SG |
| _RESPONSE_EXTENDED_DATA |
binary |
Hex-Antwort von SG |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
IS_LOESCHEN
Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
HERSTELLINFO_LESEN
Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| ID_LIEF_NR |
long |
Lieferantennummer 0xFFFFFF, falls nicht vorhanden |
| ID_LIEF_TEXT |
string |
Text zu ID_LIEF_NR table Lieferanten LIEF_TEXT unbekannter Hersteller, falls nicht vorhanden |
| ID_DATUM |
string |
Herstelldatum (DD.MM.YY) |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
| _REQUEST_2 |
binary |
Hex-Auftrag an SG |
| _RESPONSE_2 |
binary |
Hex-Antwort von SG |
DIAGNOSE_AUFRECHT
Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
Arguments
| Name |
Type |
Comment |
| SG_ANTWORT |
string |
"ja" -> SG soll antworten "nein" -> SG soll nicht antworten table DigitalArgument TEXT Default: SG soll antworten |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
DIAGNOSE_MODE
SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
Arguments
| Name |
Type |
Comment |
| MODE |
string |
gewuenschter Diagnose-Modus table DiagMode MODE MODE_TEXT Defaultwert: DEFAULT (DefaultMode) |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
ENERGIESPARMODE
Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
Arguments
| Name |
Type |
Comment |
| MODE |
int |
0x00: Normalmode 0x01: Fertigungsmode 0x02: Transportmode 0x03: Flashmode |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STATUS_ENERGIESPARMODE
Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| STAT_ENERGIESPARMODE_WERT |
int |
Ausgabe des Energiesparmodes 0: Kein Energiesparmode gesetzt 1: Produktionsmode gesetzt 2: Transportmode gesetzt 3: Flashmode gesetzt -1: Mode ungueltig |
| STAT_ENERGIESPARMODE_TEXT |
string |
Text zu STAT_ENERGIESPARMODE_WERT |
| STAT_PRODUKTIONSMODE_EIN |
int |
0: Produktionsmode nicht aktiv 1: Produktionsmode aktiv |
| STAT_TRANSPORTMODE_EIN |
int |
0: Transportmode nicht aktiv 1: Transportmode aktiv |
| STAT_FLASHMODE_EIN |
int |
0: Flashmode nicht aktiv 1: Flashmode aktiv |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STATUS_BETRIEBSMODE
Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| STAT_BETRIEBSMODE_WERT |
int |
Aktueller Betriebsmode table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle) |
| STAT_BETRIEBSMODE_TEXT |
string |
Textausgabe STAT_BETRIEBSMODE_WERT table Betriebsmode TEXT |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN_BETRIEBSMODE
Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default
Arguments
| Name |
Type |
Comment |
| BETRIEBSMODE |
int |
Betriebsmode setzen table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle) |
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERGERAETE_RESET
Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STATUS_ROE_REPORT
Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS: $86 ResponseOnEvent $04 report activated events $02 eventWindowTime - infinite (LH Diagnosemaster V11 oder höher, Umsetzung nach LH V6 - V10 wird jedoch toleriert)
No arguments.
Results
| Name |
Type |
Comment |
| STAT_ROE_AKTIV |
char |
0x00 = Aktive Fehlermeldung deaktiviert 0x01 = Aktive Fehlermeldung aktiviert 0xFF = Status der aktiven Fehlermeldung nicht feststellbar |
| STAT_ROE_AKTIV_TEXT |
string |
Interpretation von STAT_ROE_AKTIV table UDS_TAB_ROE_AKTIV TEXT |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN_ROE_PERSISTENT_STOP
Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
No arguments.
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
STEUERN_ROE_PERSISTENT_START
Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
No arguments.
Results
| Name |
Type |
Comment |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
CPS_LESEN
Codierpruefstempel lesen UDS : $22 ReadDataByIdentifier UDS : $37FE DataIdentifier Codierpruefstempel Modus: Default
No arguments.
Results
| Name |
Type |
Comment |
| CPS |
string |
Codierpruefstempel bis SP2021 bestehend aus VIN7 7 Zeichen (ASCII) Codierpruefstempel ab SP2021 bestehend aus Codierdatum 6 Zeichen (3 Byte Hex) bestehend aus TesterNr 6 Zeichen (3 Byte Hex) bestehend aus LizenzID 10 Zeichen (5 Byte Hex) bestehend aus VIN7 7 Zeichen (ASCII) |
| CPS_VIN7 |
string |
7 Zeichen (ASCII) |
| CPS_DATUM |
string |
erst ab SP2021 Codierdatum 8 Zeichen TT.MM.JJJJ |
| CPS_TESTERNR |
string |
erst ab SP2021 Tester-Nummer 6 Zeichen hex |
| CPS_LIZENZID |
string |
erst ab SP2021 Tester-Lizenz-ID 10 Zeichen hex |
| JOB_STATUS |
string |
OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST |
binary |
Hex-Auftrag an SG |
| _RESPONSE |
binary |
Hex-Antwort von SG |
Tables
Index
JOBRESULT
Dimensions: 76 rows × 2 columns
| SB |
STATUS_TEXT |
| 0x10 |
ERROR_ECU_GENERAL_REJECT |
| 0x11 |
ERROR_ECU_SERVICE_NOT_SUPPORTED |
| 0x12 |
ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED |
| 0x13 |
ERROR_ECU_INCORRECT_MESSAGE_LENGTH_OR_INVALID_FORMAT |
| 0x14 |
ERROR_ECU_RESPONSE_TOO_LONG |
| 0x21 |
ERROR_ECU_BUSY_REPEAT_REQUEST |
| 0x22 |
ERROR_ECU_CONDITIONS_NOT_CORRECT |
| 0x24 |
ERROR_ECU_REQUEST_SEQUENCE_ERROR |
| 0x25 |
ERROR_ECU_NO_RESPONSE_FROM_SUBNET_COMPONENT |
| 0x26 |
ERROR_ECU_FAILURE_PREVENTS_EXECUTION_OF_REQUESTED_ACTION |
| 0x31 |
ERROR_ECU_REQUEST_OUT_OF_RANGE |
| 0x33 |
ERROR_ECU_SECURITY_ACCESS_DENIED |
| 0x35 |
ERROR_ECU_INVALID_KEY |
| 0x36 |
ERROR_ECU_EXCEED_NUMBER_OF_ATTEMPTS |
| 0x37 |
ERROR_ECU_REQUIRED_TIME_DELAY_NOT_EXPIRED |
| 0x70 |
ERROR_ECU_UPLOAD_DOWNLOAD_NOT_ACCEPTED |
| 0x71 |
ERROR_ECU_TRANSFER_DATA_SUSPENDED |
| 0x72 |
ERROR_ECU_GENERAL_PROGRAMMING_FAILURE |
| 0x73 |
ERROR_ECU_WRONG_BLOCK_SEQUENCE_COUNTER |
| 0x78 |
ERROR_ECU_REQUEST_CORRECTLY_RECEIVED__RESPONSE_PENDING |
| 0x7E |
ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED_IN_ACTIVE_SESSION |
| 0x7F |
ERROR_ECU_SERVICE_NOT_SUPPORTED_IN_ACTIVE_SESSION |
| 0x81 |
ERROR_ECU_RPM_TOO_HIGH |
| 0x82 |
ERROR_ECU_RPM_TOO_LOW |
| 0x83 |
ERROR_ECU_ENGINE_IS_RUNNING |
| 0x84 |
ERROR_ECU_ENGINE_IS_NOT_RUNNING |
| 0x85 |
ERROR_ECU_ENGINE_RUN_TIME_TOO_LOW |
| 0x86 |
ERROR_ECU_TEMPERATURE_TOO_HIGH |
| 0x87 |
ERROR_ECU_TEMPERATURE_TOO_LOW |
| 0x88 |
ERROR_ECU_VEHICLE_SPEED_TOO_HIGH |
| 0x89 |
ERROR_ECU_VEHICLE_SPEED_TOO_LOW |
| 0x8A |
ERROR_ECU_THROTTLE_PEDAL_TOO_HIGH |
| 0x8B |
ERROR_ECU_THROTTLE_PEDAL_TOO_LOW |
| 0x8C |
ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_NEUTRAL |
| 0x8D |
ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_GEAR |
| 0x8F |
ERROR_ECU_BRAKE_SWITCH_NOT_CLOSED |
| 0x90 |
ERROR_ECU_SHIFTER_LEVER_NOT_IN_PARK |
| 0x91 |
ERROR_ECU_TORQUE_CONVERTER_CLUTCH_LOCKED |
| 0x92 |
ERROR_ECU_VOLTAGE_TOO_HIGH |
| 0x93 |
ERROR_ECU_VOLTAGE_TOO_LOW |
| ?00? |
OKAY |
| ?01? |
ERROR_ECU_NO_RESPONSE |
| ?02? |
ERROR_ECU_INCORRECT_LEN |
| ?03? |
ERROR_ECU_INCORRECT_RESPONSE_ID |
| ?04? |
ERROR_ECU_TA_RESPONSE_NOT_SA_REQUEST |
| ?05? |
ERROR_ECU_SA_RESPONSE_NOT_TA_REQUEST |
| ?06? |
ERROR_ECU_RESPONSE_INCORRECT_DATA_IDENTIFIER |
| ?07? |
ERROR_ECU_RESPONSE_TOO_MUCH_DATA |
| ?08? |
ERROR_ECU_RESPONSE_TOO_LESS_DATA |
| ?09? |
ERROR_ECU_RESPONSE_VALUE_OUT_OF_RANGE |
| ?0A? |
ERROR_TABLE |
| ?10? |
ERROR_F_CODE |
| ?12? |
ERROR_INTERPRETATION |
| ?13? |
ERROR_F_POS |
| ?14? |
ERROR_ECU_RESPONSE_INCORRECT_IO_CONTROL_PARAMETER |
| ?15? |
ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_CONTROL_TYPE |
| ?16? |
ERROR_ECU_RESPONSE_INCORRECT_SUB_FUNCTION |
| ?17? |
ERROR_ECU_RESPONSE_INCORRECT_DYNAMICALLY_DEFINED_DATA_IDENTIFIER |
| ?18? |
ERROR_ECU_RESPONSE_NO_STRING_END_CHAR |
| ?19? |
ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_IDENTIFIER |
| ?1A? |
ERROR_ECU_RESPONSE_INCORRECT_RESET_TYPE |
| ?1B? |
ERROR_ECU_RESPONSE_INCORRECT_SERIAL_NUMBER_FORMAT |
| ?1C? |
ERROR_ECU_RESPONSE_INCORRECT_DTC_BY_STATUS_MASK |
| ?1D? |
ERROR_ECU_RESPONSE_INCORRECT_DTC_STATUS_AVAILABILITY_MASK |
| ?1E? |
ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_CONTROL_IDENTIFIER |
| ?50? |
ERROR_BYTE1 |
| ?51? |
ERROR_BYTE2 |
| ?52? |
ERROR_BYTE3 |
| ?60? |
ERROR_VERIFY |
| ?61? |
ERROR_ECU_RESPONSE_ZGW |
| ?62? |
ERROR_ECU_RESPONSE_BACKUP |
| ?70? |
ERROR_CALID_CVN_INCORRECT_LEN |
| ?80? |
ERROR_SVK_INCORRECT_LEN |
| ?81? |
ERROR_SVK_INCORRECT_FINGERPRINT |
| ?F0? |
ERROR_ARGUMENT |
| 0xXY |
ERROR_ECU_UNKNOWN_NEGATIVE_RESPONSE |
LIEFERANTEN
Dimensions: 149 rows × 2 columns
| LIEF_NR |
LIEF_TEXT |
| 0x000001 |
Reinshagen / Delphi |
| 0x000002 |
Leopold Kostal GmbH & Co. KG |
| 0x000003 |
Hella Fahrzeugkomponenten GmbH |
| 0x000004 |
Siemens |
| 0x000005 |
Eaton |
| 0x000006 |
UTA |
| 0x000007 |
Helbako GmbH |
| 0x000008 |
Robert Bosch GmbH |
| 0x000009 |
Lear Corporation |
| 0x000010 |
VDO |
| 0x000011 |
Valeo GmbH |
| 0x000012 |
MBB |
| 0x000013 |
Kammerer |
| 0x000014 |
SWF |
| 0x000015 |
Blaupunkt |
| 0x000016 |
Philips |
| 0x000017 |
Alpine Electronics GmbH |
| 0x000018 |
Continental Teves AG & Co. OHG |
| 0x000019 |
Elektromatik Südafrika |
| 0x000020 |
Harman Becker Automotive Systems |
| 0x000021 |
Preh GmbH |
| 0x000022 |
Alps Electric Co. Ltd. |
| 0x000023 |
Motorola |
| 0x000024 |
Temic |
| 0x000025 |
Webasto SE |
| 0x000026 |
MotoMeter |
| 0x000027 |
Delphi Automotive PLC |
| 0x000028 |
DODUCO (Beru) |
| 0x000029 |
DENSO |
| 0x000030 |
NEC |
| 0x000031 |
DASA |
| 0x000032 |
Pioneer Corporation |
| 0x000033 |
Jatco |
| 0x000034 |
FUBA Automotive GmbH & Co. KG |
| 0x000035 |
UK-NSI |
| 0x000036 |
AABG |
| 0x000037 |
Dunlop |
| 0x000038 |
Sachs |
| 0x000039 |
ITT |
| 0x000040 |
FTE (Fahrzeugtechnik Ebern) |
| 0x000041 |
Megamos |
| 0x000042 |
TRW Automotive GmbH |
| 0x000043 |
WABCO Fahrzeugsysteme GmbH |
| 0x000044 |
ISAD Electronic Systems |
| 0x000045 |
HEC Hella Electronics Corporation |
| 0x000046 |
Gemel |
| 0x000047 |
ZF Friedrichshafen AG |
| 0x000048 |
GMPT |
| 0x000049 |
Harman Becker Automotive Systems GmbH |
| 0x000050 |
Remes GmbH |
| 0x000051 |
ZF Lenksysteme GmbH |
| 0x000052 |
Magneti Marelli S.p.A. |
| 0x000053 |
Johnson Controls Inc. |
| 0x000054 |
GETRAG Getriebe- und Zahnradf. Hermann Hagenmeyer GmbH & Co. KG |
| 0x000055 |
Behr-Hella Thermocontrol GmbH |
| 0x000056 |
Siemens VDO Automotive |
| 0x000057 |
Visteon Innovation & Technology GmbH |
| 0x000058 |
Autoliv AB |
| 0x000059 |
Haberl Electronic GmbH & Co. KG |
| 0x000060 |
Magna International Inc. |
| 0x000061 |
Marquardt GmbH |
| 0x000062 |
AB Elektronik GmbH |
| 0x000063 |
SDVO/BORG |
| 0x000064 |
Hirschmann Car Communication GmbH |
| 0x000065 |
hoerbiger-electronics |
| 0x000066 |
Thyssen Krupp Automotive |
| 0x000067 |
Gentex Corporation |
| 0x000068 |
Atena GmbH |
| 0x000069 |
Magna-Donelly |
| 0x000070 |
Koyo Steeting Europe |
| 0x000071 |
NSI Beheer B.V. |
| 0x000072 |
Aisin AW Co. Ltd. |
| 0x000073 |
Schorlock |
| 0x000074 |
Schrader Electronics Ltd. |
| 0x000075 |
Huf-Electronics Bretten GmbH |
| 0x000076 |
CEL |
| 0x000077 |
AUDIO MOBIL Elektronik GmbH |
| 0x000078 |
rd electronic |
| 0x000079 |
iSYS RTS GmbH |
| 0x000080 |
Westfalia-Automotive GmbH |
| 0x000081 |
Tyco Electronics |
| 0x000082 |
Paragon AG |
| 0x000083 |
IEE S.A. |
| 0x000084 |
TEMIC AUTOMOTIVE of NA |
| 0x000085 |
Sonceboz S.A. |
| 0x000086 |
Meta System S.p.A. |
| 0x000087 |
Huf Hülsbeck & Fürst GmbH & Co. KG |
| 0x000088 |
MANN+HUMMEL GmbH |
| 0x000089 |
Brose Fahrzeugteile GmbH & Co. |
| 0x000090 |
Keihin |
| 0x000091 |
Vimercati S.p.a |
| 0x000092 |
CRH |
| 0x000093 |
TPO Display Corp |
| 0x000094 |
Küster Automotive GmbH |
| 0x000095 |
Hitachi Automotive |
| 0x000096 |
Continental AG |
| 0x000097 |
TI-Automotive |
| 0x000098 |
Hydro |
| 0x000099 |
Johnson Controls Inc. |
| 0x00009A |
Takata-Petri |
| 0x00009B |
Mitsubishi Electric B.V. (Melco) |
| 0x00009C |
Autokabel |
| 0x00009D |
GKN Plc |
| 0x00009E |
Zollner Elektronik AG |
| 0x00009F |
peiker acustic GmbH & Co. KG |
| 0x0000A0 |
Bosal-Oris |
| 0x0000A1 |
Cobasys |
| 0x0000A2 |
Automotive Lighting Reutlingen GmbH |
| 0x0000A3 |
CONTI VDO |
| 0x0000A4 |
A.D.C. Automotive Distance Control Systems GmbH |
| 0x0000A5 |
Novero Dabendorf GmbH |
| 0x0000A6 |
LAMES S.p.a. |
| 0x0000A7 |
Magna/Closures |
| 0x0000A8 |
Harbin Wan Yu Technology Co |
| 0x0000A9 |
ThyssenKrupp Presta AG |
| 0x0000AA |
ArvinMeritor |
| 0x0000AB |
Kongsberg Automotive GmbH |
| 0x0000AC |
SMR Automotive Mirrors Stuttgart GmbH |
| 0x0000AD |
So.Ge.Mi. |
| 0x0000AE |
MTA S.p.A. |
| 0x0000AF |
Alfmeier Präzision AG |
| 0x0000B0 |
Eltek Deutechland GmbH |
| 0x0000B1 |
OMRON Automotive Electronics Europe GmbH |
| 0x0000B2 |
ASK Industries GmbH |
| 0x0000B3 |
CML Innovative Technologies GmbH & Co. KG |
| 0x0000B4 |
APAG Elektronik AG |
| 0x0000B5 |
Nexteer Automotive |
| 0x0000B6 |
Hans Widmaier Fernmelde- und Feinwerktechnik |
| 0x0000B7 |
Robert Bosch Battery Systems GmbH |
| 0x0000B8 |
Kyocera Display Europe GmbH |
| 0x0000B9 |
Magna Powertrain AG & Co. KG |
| 0x0000BA |
BorgWarner Beru Systems GmbH |
| 0x0000BB |
BMW AG |
| 0x0000BC |
Benteler Duncan Plant |
| 0x0000BD |
U-Shin Deutschland Zugangssysteme GmbH |
| 0x0000BE |
Schaeffler Technologies AG & Co. KG |
| 0x0000BF |
JTEKT Corporation |
| 0x0000C0 |
VLF |
| 0x0000C1 |
Flextronics |
| 0x0000C2 |
LG Chem |
| 0x0000C3 |
Panasonic |
| 0x0000C4 |
Alpitronic GmbH |
| 0x0000C5 |
Telemotive AG |
| 0x0000C6 |
Garmin |
| 0x0000C7 |
RSG Elotech Elektronische Baugruppen GmbH |
| 0x0000C8 |
KEBODA TECHNOLOGY CORP |
| 0x0000C9 |
Aptiv |
| 0x0000CA |
SEG Automotive Germany GmbH |
| 0xFFFFFF |
unbekannter Hersteller |
FARTTEXTE
Dimensions: 35 rows × 2 columns
| ARTNR |
ARTTEXT |
| 0x00 |
keine Fehlerart verfügbar |
| 0x04 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x05 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x08 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x09 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x0C |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x0D |
Fehler momentan vorhanden und bereits gespeichert |
| 0x20 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x21 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x24 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x25 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x28 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x29 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x2C |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x2D |
Fehler momentan vorhanden und bereits gespeichert |
| 0x40 |
unbekannte Fehlerart |
| 0x44 |
Fehler gespeichert |
| 0x45 |
Fehler gespeichert |
| 0x48 |
Fehler gespeichert |
| 0x49 |
Fehler gespeichert |
| 0x4C |
Fehler gespeichert |
| 0x4D |
Fehler gespeichert |
| 0x60 |
Fehler gespeichert |
| 0x61 |
Fehler gespeichert |
| 0x64 |
Fehler gespeichert |
| 0x65 |
Fehler gespeichert |
| 0x68 |
Fehler gespeichert |
| 0x69 |
Fehler gespeichert |
| 0x6C |
Fehler gespeichert |
| 0x6D |
Fehler gespeichert |
| 0x10 |
Testbedingungen erfüllt |
| 0x11 |
Testbedingungen noch nicht erfüllt |
| 0x80 |
Fehler würde kein Aufleuchten einer Warnlampe verursachen |
| 0x81 |
Fehler würde das Aufleuchten einer Warnlampe verursachen |
| 0xFF |
unbekannte Fehlerart |
DIGITALARGUMENT
Dimensions: 17 rows × 2 columns
| TEXT |
WERT |
| ein |
1 |
| aus |
0 |
| ja |
1 |
| nein |
0 |
| auf |
1 |
| ab |
0 |
| an |
1 |
| yes |
1 |
| no |
0 |
| on |
1 |
| off |
0 |
| up |
1 |
| down |
0 |
| true |
1 |
| false |
0 |
| 1 |
1 |
| 0 |
0 |
PROZESSKLASSEN
Dimensions: 26 rows × 3 columns
| WERT |
PROZESSKLASSE |
BEZEICHNUNG |
| 0x00 |
- |
ungueltig |
| 0x01 |
HWEL |
Hardware (Elektronik) |
| 0x02 |
HWAP |
Hardwareauspraegung |
| 0x03 |
HWFR |
Hardwarefarbe |
| 0x05 |
CAFD |
Codierdaten |
| 0x06 |
BTLD |
Bootloader |
| 0x08 |
SWFL |
Software ECU Speicherimage |
| 0x09 |
SWFF |
Flash File Software |
| 0x0A |
SWPF |
Pruefsoftware |
| 0x0B |
ONPS |
Onboard Programmiersystem |
| 0x0F |
FAFP |
FA2FP |
| 0x1A |
TLRT |
Temporaere Loeschroutine |
| 0x1B |
TPRG |
Temporaere Programmierroutine |
| 0x07 |
FLSL |
Flashloader Slave |
| 0x0C |
IBAD |
Interaktive Betriebsanleitung Daten |
| 0x10 |
FCFA |
Freischaltcode Fahrzeug-Auftrag |
| 0x1C |
BLUP |
Bootloader-Update Applikation |
| 0x1D |
FLUP |
Flashloader-Update Applikation |
| 0xC0 |
SWUP |
Software-Update Package |
| 0xC1 |
SWIP |
Index Software-Update Package |
| 0xA0 |
ENTD |
Entertainment Daten |
| 0xA1 |
NAVD |
Navigation Daten |
| 0xA2 |
FCFN |
Freischaltcode Funktion |
| 0x04 |
GWTB |
Gateway-Tabelle |
| 0x0D |
SWFK |
BEGU: Detaillierung auf SWE-Ebene |
| 0xFF |
- |
ungueltig |
SVK_ID
Dimensions: 65 rows × 2 columns
| WERT |
BEZEICHNUNG |
| 0x01 |
SVK_AKTUELL |
| 0x02 |
SVK_SUPPLIER |
| 0x03 |
SVK_WERK |
| 0x04 |
SVK_BACKUP_01 |
| 0x05 |
SVK_BACKUP_02 |
| 0x06 |
SVK_BACKUP_03 |
| 0x07 |
SVK_BACKUP_04 |
| 0x08 |
SVK_BACKUP_05 |
| 0x09 |
SVK_BACKUP_06 |
| 0x0A |
SVK_BACKUP_07 |
| 0x0B |
SVK_BACKUP_08 |
| 0x0C |
SVK_BACKUP_09 |
| 0x0D |
SVK_BACKUP_10 |
| 0x0E |
SVK_BACKUP_11 |
| 0x0F |
SVK_BACKUP_12 |
| 0x10 |
SVK_BACKUP_13 |
| 0x11 |
SVK_BACKUP_14 |
| 0x12 |
SVK_BACKUP_15 |
| 0x13 |
SVK_BACKUP_16 |
| 0x14 |
SVK_BACKUP_17 |
| 0x15 |
SVK_BACKUP_18 |
| 0x16 |
SVK_BACKUP_19 |
| 0x17 |
SVK_BACKUP_20 |
| 0x18 |
SVK_BACKUP_21 |
| 0x19 |
SVK_BACKUP_22 |
| 0x1A |
SVK_BACKUP_23 |
| 0x1B |
SVK_BACKUP_24 |
| 0x1C |
SVK_BACKUP_25 |
| 0x1D |
SVK_BACKUP_26 |
| 0x1E |
SVK_BACKUP_27 |
| 0x1F |
SVK_BACKUP_28 |
| 0x20 |
SVK_BACKUP_29 |
| 0x21 |
SVK_BACKUP_30 |
| 0x22 |
SVK_BACKUP_31 |
| 0x23 |
SVK_BACKUP_32 |
| 0x24 |
SVK_BACKUP_33 |
| 0x25 |
SVK_BACKUP_34 |
| 0x26 |
SVK_BACKUP_35 |
| 0x27 |
SVK_BACKUP_36 |
| 0x28 |
SVK_BACKUP_37 |
| 0x29 |
SVK_BACKUP_38 |
| 0x2A |
SVK_BACKUP_39 |
| 0x2B |
SVK_BACKUP_40 |
| 0x2C |
SVK_BACKUP_41 |
| 0x2D |
SVK_BACKUP_42 |
| 0x2E |
SVK_BACKUP_43 |
| 0x2F |
SVK_BACKUP_44 |
| 0x30 |
SVK_BACKUP_45 |
| 0x31 |
SVK_BACKUP_46 |
| 0x32 |
SVK_BACKUP_47 |
| 0x33 |
SVK_BACKUP_48 |
| 0x34 |
SVK_BACKUP_49 |
| 0x35 |
SVK_BACKUP_50 |
| 0x36 |
SVK_BACKUP_51 |
| 0x37 |
SVK_BACKUP_52 |
| 0x38 |
SVK_BACKUP_53 |
| 0x39 |
SVK_BACKUP_54 |
| 0x3A |
SVK_BACKUP_55 |
| 0x3B |
SVK_BACKUP_56 |
| 0x3C |
SVK_BACKUP_57 |
| 0x3D |
SVK_BACKUP_58 |
| 0x3E |
SVK_BACKUP_59 |
| 0x3F |
SVK_BACKUP_60 |
| 0x40 |
SVK_BACKUP_61 |
| 0xXY |
ERROR_UNKNOWN |
DTCEXTENDEDDATARECORDNUMBER
Dimensions: 5 rows × 3 columns
| WERT |
TEXT |
ANZ_BYTE |
| 0x00 |
ISO_RESERVED |
0 |
| 0x01 |
CONDITION_BYTE |
1 |
| 0x02 |
HFK |
1 |
| 0x03 |
HLZ |
1 |
| 0xFF |
RECORD_UNKNOWN |
0 |
DTCSNAPSHOTIDENTIFIER
Dimensions: 9 rows × 9 columns
| UWNR |
UWTEXT |
UW_EINH |
L/H |
UWTYP |
NAME |
MUL |
DIV |
ADD |
| 0x1700 |
KM_STAND |
0-n |
- |
0xFFFFFF |
- |
1 |
1 |
0.000000 |
| 0x1701 |
ABS_ZEIT |
0-n |
- |
0xFFFFFFFF |
- |
1 |
1 |
0.000000 |
| 0x1702 |
SAE_CODE |
0-n |
- |
0xFFFFFF |
- |
1 |
1 |
0.000000 |
| 0x1731 |
Fehlerklasse_DTC |
- |
- |
u char |
- |
1 |
1 |
0.000000 |
| 0x1750 |
PWF_Basinetz |
0-n |
- |
0xFF |
- |
1 |
1 |
0.000000 |
| 0x1751 |
PWF_Teilnetz |
0-n |
- |
0xFFFFFF |
- |
1 |
1 |
0.000000 |
| 0x1768 |
KM_STAND_SUP |
0-n |
- |
0xFFFFFFFF |
- |
1 |
1 |
0.000000 |
| 0x1769 |
ABS_ZEIT_SUP |
0-n |
- |
0xFFFFFFFF |
- |
1 |
1 |
0.000000 |
| 0xFFFF |
IDENTIFIER_UNKNOWN |
- |
- |
0xFFFFFF |
- |
1 |
1 |
0.000000 |
TAB_ZEIT_SYNCMETHOD
Dimensions: 4 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
Combi-Time |
| 0x01 |
DMCS |
| 0x02 |
IEEE802.1AS |
| 0x03 |
invalid |
TAB_ZEIT_USER_INFO
Dimensions: 8 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
out of sync, no time available |
| 0x01 |
ms ECU overall, not comparable |
| 0x02 |
ms ECU overall, not comparable |
| 0x03 |
invalid |
| 0x04 |
insync, ms ECU overall, not comparable |
| 0x05 |
ms ECU overall, comparable |
| 0x06 |
ms ECU overall, comparable |
| 0x07 |
invalid |
FEHLERKLASSE
Dimensions: 5 rows × 2 columns
| NR |
TEXT |
| 0x00 |
Keine Fehlerklasse verfuegbar |
| 0x01 |
Ueberpruefung bei naechstem Werkstattbesuch |
| 0x02 |
Ueberpruefung bei naechstem Halt |
| 0x04 |
Ueberpruefung sofort erforderlich ! |
| 0xFF |
unbekannte Fehlerklasse |
DIAGMODE
Dimensions: 14 rows × 3 columns
| NR |
MODE |
MODE_TEXT |
| 0x00 |
UNGUELTIG |
DefaultMode |
| 0x01 |
DEFAULT |
DefaultMode |
| 0x02 |
ECUPM |
ECUProgrammingMode |
| 0x03 |
ECUEXTDIAG |
ECUExtendedDiagnosticSession |
| 0x04 |
ECUSSDS |
ECUSafetySystemDiagnosticSession |
| 0x40 |
ECUEOL |
ECUEndOfLineSession |
| 0x41 |
ECUCODE |
ECUCodingSession |
| 0x42 |
ECUSWT |
ECUSwtSession |
| 0x43 |
ECUHDD |
ECUHDDDownloadSession |
| 0x44 |
ECURSU |
ECURsuSession |
| 0x4F |
ECUDEVELOP |
ECUDevelopmentSession |
| 0x5F |
ECUGDM |
ECUGarageDiagnoseMode |
| 0x61 |
ECUSUPSPEC |
ECUSupplierSpecificSession |
| 0xXY |
-- |
unbekannter Diagnose-Mode |
IARTTEXTE
Dimensions: 35 rows × 2 columns
| ARTNR |
ARTTEXT |
| 0x00 |
keine Fehlerart verfügbar |
| 0x04 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x05 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x08 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x09 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x0C |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x0D |
Fehler momentan vorhanden und bereits gespeichert |
| 0x20 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x21 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x24 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x25 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x28 |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x29 |
Fehler momentan vorhanden und bereits gespeichert |
| 0x2C |
Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x2D |
Fehler momentan vorhanden und bereits gespeichert |
| 0x40 |
unbekannte Fehlerart |
| 0x44 |
Fehler gespeichert |
| 0x45 |
Fehler gespeichert |
| 0x48 |
Fehler gespeichert |
| 0x49 |
Fehler gespeichert |
| 0x4C |
Fehler gespeichert |
| 0x4D |
Fehler gespeichert |
| 0x60 |
Fehler gespeichert |
| 0x61 |
Fehler gespeichert |
| 0x64 |
Fehler gespeichert |
| 0x65 |
Fehler gespeichert |
| 0x68 |
Fehler gespeichert |
| 0x69 |
Fehler gespeichert |
| 0x6C |
Fehler gespeichert |
| 0x6D |
Fehler gespeichert |
| 0x10 |
Testbedingungen erfüllt |
| 0x11 |
Testbedingungen noch nicht erfüllt |
| 0x80 |
Fehler würde kein Aufleuchten einer Warnlampe verursachen |
| 0x81 |
Fehler würde das Aufleuchten einer Warnlampe verursachen |
| 0xFF |
unbekannte Fehlerart |
UDS_TAB_ROE_AKTIV
Dimensions: 3 rows × 2 columns
| NR |
TEXT |
| 0x00 |
Aktive Fehlermeldung deaktiviert |
| 0x01 |
Aktive Fehlermeldung aktiviert |
| 0xFF |
Status der aktiven Fehlermeldung nicht feststellbar |
ARG_0X4017_D
Dimensions: 1 rows × 12 columns
| ARG |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| QUALIFIER_ALIGNMENT |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
1.0 |
QUALIFIER_ALIGNMENT |
ARG_0X4019_D
Dimensions: 1 rows × 12 columns
| ARG |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| QUALIFIER_REICHWEITE |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
1.0 |
QUALIFIER_REICHWEITE |
ARG_0XA158_R
Dimensions: 1 rows × 14 columns
| ARG |
STR |
STPR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| GESCHWINDIGKEIT_ZIEL |
+ |
- |
km/h |
high |
signed int |
- |
- |
1.0 |
1.0 |
0.0 |
-150.0 |
150.0 |
Geschwindigkeit des zu suchenden Ziels (Wertebereich -150 km/h bis +150 km/h, Auflösung 1km/h Schritte) |
ARG_0XA159_R
Dimensions: 5 rows × 14 columns
| ARG |
STR |
STPR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| MESSGERAET |
+ |
- |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
255.0 |
Gerät zur Zielerzeugung (Gerät1, Gerät2, Gerät3 usw.) |
| WINKEL_ZIEL |
+ |
- |
° |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
360.0 |
Winkel unter dem das zu suchende Ziel sich befindet ( Wertebereich 0° bis 360°, Schrittweite 1.0°) |
| ABSTAND_ZIEL |
+ |
- |
m |
high |
unsigned int |
- |
- |
10.0 |
1.0 |
0.0 |
0.0 |
300.0 |
Abstand des zu suchenden Ziels (Wertebereich 0 m bis 300 m, Auflösung 0,1 m Schritte) |
| GESCHWINDIGKEIT_ZIEL |
+ |
- |
km/h |
high |
signed int |
- |
- |
1.0 |
1.0 |
0.0 |
-150.0 |
150.0 |
Geschwindigkeit des zu suchenden Ziels (Wertebereich -150 km/h bis +150 km/h, Auflösung 1km/h Schritte) |
| GROESSE_ZIEL |
+ |
- |
dBm |
high |
unsigned int |
- |
- |
10.0 |
1.0 |
0.0 |
0.0 |
50.0 |
Größe des zu suchenden Ziels (Wertebereich 0 dBsm bis 50 dBsm, Auflösung 0,1 dBsm) |
ARG_0XA15A_R
Dimensions: 4 rows × 14 columns
| ARG |
STR |
STPR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| WINKEL_ZIEL |
+ |
- |
° |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
360.0 |
Winkel unter dem das zu suchende Ziel sich befindet ( Wertebereich 0° bis 360°, Schrittweite 1.0°) |
| ABSTAND_ZIEL |
+ |
- |
m |
high |
unsigned int |
- |
- |
10.0 |
1.0 |
0.0 |
0.0 |
300.0 |
Abstand des zu suchenden Ziels (Wertebereich 0 m bis 300 m, Auflösung 0,1 m Schritte) |
| GESCHWINDIGKEIT_ZIEL |
+ |
- |
km/h |
high |
signed int |
- |
- |
1.0 |
1.0 |
0.0 |
-150.0 |
150.0 |
Geschwindigkeit des zu suchenden Ziels (Wertebereich -150 km/h bis +150 km/h, Auflösung 1km/h Schritte) |
| GROESSE_ZIEL |
+ |
- |
dBm |
high |
unsigned int |
- |
- |
10.0 |
1.0 |
0.0 |
0.0 |
50.0 |
Größe des zu suchenden Ziels (Wertebereich 0 dBsm bis 50 dBsm, Auflösung 0,1 dBsm) |
ARG_0XA15B_R
Dimensions: 5 rows × 14 columns
| ARG |
STR |
STPR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| MESSGERAET |
+ |
- |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
255.0 |
Gerät zur Zielerzeugung (Gerät1, Gerät2, Gerät3 usw.) |
| WINKEL_ZIEL |
+ |
- |
° |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
0.0 |
360.0 |
Winkel unter dem das zu suchende Ziel sich befindet ( Wertebereich 0° bis 360°, Schrittweite 1.0°) |
| ABSTAND_ZIEL |
+ |
- |
m |
high |
unsigned int |
- |
- |
10.0 |
1.0 |
0.0 |
0.0 |
300.0 |
Abstand des zu suchenden Ziels (Wertebereich 0 m bis 300 m, Auflösung 0,1 m Schritte) |
| GESCHWINDIGKEIT_ZIEL |
+ |
- |
km/h |
high |
signed int |
- |
- |
1.0 |
1.0 |
0.0 |
-150.0 |
150.0 |
Geschwindigkeit des zu suchenden Ziels (Wertebereich -150 km/h bis +150 km/h, Auflösung 1km/h Schritte) |
| GROESSE_ZIEL |
+ |
- |
dBsm |
high |
unsigned int |
- |
- |
10.0 |
1.0 |
250.0 |
-25.0 |
25.0 |
Größe des zu suchenden Ziels (Wertebereich -25 dBsm bis 25dBsm, Auflösung 0,1 dBsm) |
ARG_0XF002_R
Dimensions: 1 rows × 14 columns
| ARG |
STR |
STPR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
MIN |
MAX |
INFO |
| ARG1 |
+ |
- |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
- |
- |
First argument |
BF_22_F152_SUPPLIERINFO
Dimensions: 2 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_HWMODEL |
0-n |
high |
unsigned char |
0xC0 |
HW_MODEL |
- |
- |
- |
hardware model |
| STAT_SUPPLIERINFOFIELD |
0-n |
high |
unsigned char |
0x3F |
TAB_SUPPLIERINFO_FIELD |
- |
- |
- |
supplierInfo |
BETRIEBSMODE
Dimensions: 6 rows × 3 columns
| WERT |
TEXT |
BEDEUTUNG |
| 0x00 |
Allgemeiner Fertigungs- und Energiesparmode |
Hier deaktivierte Funktionen gemäß FeTra-Liste festhalten |
| 0x01 |
Spezieller Energiesparmode |
- |
| 0x02 |
ECOS-Mode |
- |
| 0x03 |
MOST-Mode |
- |
| 0x04 |
Rollenmode |
- |
| 0xFF |
ungültiger Betriebsmode |
ungültig |
FDETAILSTRUKTUR
Dimensions: 6 rows × 2 columns
| NAME |
TYP |
| F_UWB_ERW |
ja |
| SAE_CODE |
nein |
| F_HLZ |
nein |
| F_SEVERITY |
nein |
| F_UWB_SATZ |
2 |
| F_HLZ_VIEW |
nein |
FORTTEXTE
Dimensions: 10 rows × 4 columns
| ORT |
ORTTEXT |
EREIGNIS_DTC |
FEHLERKLASSE |
| 0x022000 |
Energiesparmode aktiv |
0 |
- |
| 0x022008 |
Codierung: Steuergerät ist nicht codiert |
0 |
- |
| 0x022009 |
Codierung: Fehler bei Codierdatentransaktion aufgetreten |
0 |
- |
| 0x02200A |
Codierung: Signatur der Codierdaten ungültig |
0 |
- |
| 0x02200B |
Codierung: Codierdaten passen nicht zum Fahrzeug |
0 |
- |
| 0x02200C |
Codierung: Unplausible Daten während Codierdatentransaktion |
0 |
- |
| 0x02200D |
Codierung: Codierdaten nicht qualifiziert |
0 |
- |
| 0x02FF20 |
Dummy-Fehlerspeichereintrag im Komponentenfehlerbereich nur für Testzwecke |
1 |
- |
| 0xD10BFF |
Dummy-Fehlerspeichereintrag im Netzwerkfehlerbereich nur für Testzwecke |
1 |
- |
| 0xFFFFFF |
unbekannter Fehlerort |
0 |
- |
FUMWELTTEXTE
Dimensions: 2 rows × 9 columns
| UWNR |
UWTEXT |
UW_EINH |
L/H |
UWTYP |
NAME |
MUL |
DIV |
ADD |
| 0x1750 |
F_UW_BN |
- |
High |
unsigned char |
- |
1.0 |
1.0 |
0.0 |
| 0xXYXY |
unbekannte Umweltbedingung |
- |
- |
- |
- |
- |
- |
- |
HW_MODEL
Dimensions: 5 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
A-Muster |
| 0x40 |
B-Muster |
| 0x80 |
C-Muster |
| 0xC0 |
D-Muster |
| 0xFF |
Wert ungültig |
IDETAILSTRUKTUR
Dimensions: 5 rows × 2 columns
| NAME |
TYP |
| F_UWB_ERW |
ja |
| SAE_CODE |
nein |
| F_HLZ |
nein |
| F_SEVERITY |
nein |
| F_UWB_SATZ |
2 |
IORTTEXTE
Dimensions: 4 rows × 4 columns
| ORT |
ORTTEXT |
EREIGNIS_DTC |
FEHLERKLASSE |
| 0x600000 |
SG intern - Reset |
0 |
- |
| 0x600002 |
Extended internal Info |
0 |
- |
| 0x600003 |
Frame-Drop FASR-CAN |
0 |
- |
| 0xFFFFFF |
unbekannter Fehlerort |
0 |
- |
IUMWELTTEXTE
Dimensions: 16 rows × 9 columns
| UWNR |
UWTEXT |
UW_EINH |
L/H |
UWTYP |
NAME |
MUL |
DIV |
ADD |
| 0x1750 |
F_UW_BN |
- |
High |
unsigned char |
- |
1.0 |
1.0 |
0.0 |
| 0x2866 |
STAT_BETRIEBSSPANNUNG_WERT |
V |
High |
unsigned char |
- |
8.0 |
100.0 |
0.0 |
| 0x2867 |
STAT_FAHRZEUGGESCHWINDIGKEIT_WERT |
km/h |
High |
unsigned char |
- |
1.0 |
1.0 |
0.0 |
| 0x5001 |
RESET_FILE_ID |
HEX |
High |
unsigned int |
- |
- |
- |
- |
| 0x5002 |
RESET_ERROR_ID |
HEX |
High |
unsigned int |
- |
- |
- |
- |
| 0x5003 |
RESET_LINE |
HEX |
High |
unsigned long |
- |
- |
- |
- |
| 0x5004 |
RESET_REASON |
0-n |
High |
0xFF |
TAB_RESET_REASON |
- |
- |
- |
| 0x500B |
EXTENDED_INFO_1 |
HEX |
High |
unsigned long |
- |
- |
- |
- |
| 0x500C |
EXTENDED_INFO_2 |
HEX |
High |
unsigned int |
- |
- |
- |
- |
| 0x500D |
EXTENDED_INFO_3 |
HEX |
High |
unsigned int |
- |
- |
- |
- |
| 0x500E |
EXTENDED_INFO_4 |
HEX |
High |
unsigned int |
- |
- |
- |
- |
| 0x500F |
FD_INFO_1 |
HEX |
High |
unsigned long |
- |
- |
- |
- |
| 0x5011 |
FD_INFO_2 |
HEX |
High |
unsigned int |
- |
- |
- |
- |
| 0x5012 |
FD_INFO_3 |
HEX |
High |
unsigned int |
- |
- |
- |
- |
| 0x5013 |
FD_INFO_4 |
HEX |
High |
unsigned int |
- |
- |
- |
- |
| 0xXYXY |
unbekannte Umweltbedingung |
- |
- |
- |
- |
- |
- |
- |
JOBRESULTEXTENDED
Dimensions: 1 rows × 2 columns
| SB |
STATUS_TEXT |
| 0xXY |
ERROR_UNKNOWN |
RDBI_ADS_DOP
Dimensions: 10 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
ISOSAEReserved_00 |
| 0x01 |
defaultSession |
| 0x02 |
programmingSession |
| 0x03 |
extendedDiagnosticSession |
| 0x04 |
safetySystemDiagnosticSession |
| 0x40 |
vehicleManufacturerSpecific_40 |
| 0x41 |
codingSession |
| 0x42 |
SWTSession |
| 0x43 |
HDDUpdateSession |
| 0xff |
ungültig |
RES_0X2504_D
Dimensions: 6 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_ERASE_MEMORY_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
EraseMemoryTime, maximale SWE-Löschzeit mit Ablaufkontrolle im Steuergerät. |
| STAT_CHECK_MEMORY_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
CheckMemoryTime (Bsp.: Signaturprüfung), maximale Speicherprüfzeit mit Ablaufkontrolle im Steuergerät. |
| STAT_BOOTLOADER_INSTALLATION_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
BootloaderInstallationTime Die Zeit, die nach dem Reset benötigt wird, damit der Hilfsbootloader gestartet wird, den Bootloader löscht, den neuen Bootloader kopiert, dessen Signatur prüf und der neue Bootloader gestartet wird bis er wieder diagnosefähig ist. Angabe ist verpflichtend für alle Steuergeräte, auch wenn das Steuergerät keinen Bootloader Update geplant hat. Ein Wert von 0x0000 ist verboten. |
| STAT_AUTHENTICATION_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
AuthenticationTime, die maximale Zeit, die das Steuergerät zur Prüfung der Authentisierung (sendKey) benötigt mit Ablaufkontrolle im Steuergerät. |
| STAT_RESET_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
ResetTime Die Zeitangabe bezieht sich auf den Übergang von der ApplicationExtendedSesssion in die ProgrammingSession bzw. bei Übergang von der ProgrammingSession in die DefaultSession. Es ist der Maximalwert auszugeben. Nach Ablauf der ResetTime ist das Steuergerät durch Diagnose ansprechbar. |
| STAT_TRANSFER_DATA_TIME_WERT |
s |
high |
unsigned int |
- |
- |
1.0 |
1.0 |
0.0 |
TransferDataTime Die Angabe hat sich zu beziehen auf einen TransferData mit maximaler Blocklänge auf die Zeitspanne vom vollständigen Empfang der Daten im Steuergerät über das ggf. erforderliche Dekomprimieren und dem vollständigen Speichern im nichtflüchtigen Speicher bis einschließlich dem Senden der positiven Response. |
RES_0X4006_R
Dimensions: 1 rows × 13 columns
| RESULTNAME |
STR |
STPR |
RRR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_RAM_DATEN_SCHREIBEN |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
STATUS_RAM_DATEN_SCHREIBEN_TAB |
- |
- |
- |
Status RAM_DATEN_SCHREIBEN |
RES_0X4019_D
Dimensions: 1 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_QUALIFIER_REICHWEITE_WERT |
- |
high |
unsigned char |
- |
- |
1.0 |
1.0 |
0.0 |
Auslesen Qualifier Reichweite |
RES_0XA158_R
Dimensions: 2 rows × 13 columns
| RESULTNAME |
STR |
STPR |
RRR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_SRR_KALIBRIERUNG_STATUS_DETAIL |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_STATUS_ROUTINE |
- |
- |
- |
Ausführungsstatus |
| STAT_SRR_KALIBRIERUNG_FEHLER_DETAIL |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_SRR_FEHLER_DETAIL |
- |
- |
- |
Fehler Detail |
RES_0XA159_R
Dimensions: 2 rows × 13 columns
| RESULTNAME |
STR |
STPR |
RRR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_SRR_KALIBRIERUNG_STATUS_DETAIL |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_STATUS_ROUTINE |
- |
- |
- |
Ausführungsstatus |
| STAT_SRR_KALIBRIERUNG_FEHLER_DETAIL |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_SRR_FEHLER_DETAIL |
- |
- |
- |
Fehler Detail |
RES_0XA15A_R
Dimensions: 2 rows × 13 columns
| RESULTNAME |
STR |
STPR |
RRR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_SRR_DAEMPFUNGSMESSUNG_STATUS_DETAIL |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_STATUS_ROUTINE |
- |
- |
- |
Ausführungsstatus |
| STAT_SRR_DAEMPUNGSMESSUNG_FEHLER_DETAIL |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_SRR_FEHLER_DETAIL |
- |
- |
- |
Fehler Detail |
RES_0XA15B_R
Dimensions: 2 rows × 13 columns
| RESULTNAME |
STR |
STPR |
RRR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_SRR_DAEMPFUNG_STATUS_DETAIL |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_STATUS_ROUTINE |
- |
- |
- |
Ausführungsstatus |
| STAT_SRR_DAEMPFUNG_FEHLER_DETAIL |
- |
- |
+ |
0-n |
high |
unsigned char |
- |
TAB_SRR_FEHLER_DETAIL |
- |
- |
- |
Fehler Detail |
RES_0XE2BB_D
Dimensions: 6 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_AMPLITUDE_DETEKTION_WERT |
dBm |
high |
signed int |
- |
- |
1.0 |
10.0 |
0.0 |
Amplitude der Detektion |
| STAT_STANDARDABWEICHUNG_AMPLITUDE_WERT |
dB |
high |
signed int |
- |
- |
1.0 |
10.0 |
0.0 |
Standardabweichung der gemessenen Amplitude |
| STAT_MIN_AMPLITUDE_WERT |
dBm |
high |
signed int |
- |
- |
1.0 |
10.0 |
0.0 |
Benötigte Minimal-Amplitude |
| STAT_RCS_DETEKTION_WERT |
dBsm |
high |
signed int |
- |
- |
1.0 |
10.0 |
0.0 |
RCS-Wert der Detektion |
| STAT_ABSTAND_DETEKTION_WERT |
m |
high |
signed int |
- |
- |
1.0 |
10.0 |
0.0 |
Abstand der Detektion |
| STAT_AZIMUTH_DETEKTION_WERT |
° |
high |
signed int |
- |
- |
1.0 |
10.0 |
0.0 |
Azimuth-Winkel der Detektion |
RES_0XF002_R
Dimensions: 3 rows × 13 columns
| RESULTNAME |
STR |
STPR |
RRR |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_RES1_WERT |
+ |
- |
- |
HEX |
high |
unsigned long |
- |
- |
- |
- |
- |
First result |
| STAT_RES2_WERT |
+ |
- |
- |
HEX |
high |
unsigned int |
- |
- |
- |
- |
- |
Second result |
| STAT_RES3_WERT |
+ |
- |
- |
HEX |
high |
unsigned int |
- |
- |
- |
- |
- |
Third result |
RES_0XF152_D
Dimensions: 2 rows × 10 columns
| RESULTNAME |
EINHEIT |
L/H |
DATENTYP |
MASKE |
NAME |
MUL |
DIV |
ADD |
INFO |
| STAT_HW_MODIFICATION_INDEX_WERT |
HEX |
high |
unsigned char |
- |
- |
- |
- |
- |
Index of hardware modification: FF: Not supported index |
| - |
Bit |
high |
BITFIELD |
- |
BF_22_F152_SUPPLIERINFO |
- |
- |
- |
Tab Supplierinfo |
SG_FUNKTIONEN
Dimensions: 15 rows × 16 columns
| ARG |
ID |
RESULTNAME |
INFO |
EINHEIT |
LABEL |
L/H |
DATENTYP |
NAME |
MUL |
DIV |
ADD |
SG_ADR |
SERVICE |
ARG_TABELLE |
RES_TABELLE |
| FLASH_TIMING_PARAMETER |
0x2504 |
- |
Programmierspezifische Timing Parameter |
- |
- |
- |
- |
- |
- |
- |
- |
- |
22 |
- |
RES_0x2504_D |
| MILE_KM_EEPROM |
0x2540 |
STAT_MILE_KM_EEPROM_DATA |
Im EEPROM abgelegter Kilometerstand. |
DATA |
- |
High |
data[3] |
- |
1.0 |
1.0 |
0.0 |
- |
22 |
- |
- |
| RAM_DATEN_SCHREIBEN |
0x4006 |
- |
Dient dazu während der Inbetriebnahme angelernte applikative Daten in den nichtflüchtigen Speicher zu sichern. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
- |
RES_0x4006_R |
| STEUERN_QUALIFIER_ALIGNMENT |
0x4017 |
- |
STEUERN_QUALIFIER_ALIGNMENT |
- |
- |
- |
- |
- |
- |
- |
- |
- |
2E |
ARG_0x4017_D |
- |
| STATUS_QUALIFIER_ALIGNMENT |
0x4018 |
STAT_QUALIFIER_ALIGNMENT_WERT |
Auslesen des Qualifier Alignment |
- |
- |
High |
unsigned char |
- |
1.0 |
1.0 |
0.0 |
- |
22 |
- |
- |
| QUALIFIER_REICHWEITE |
0x4019 |
- |
QUALIFIER_REICHWEITE |
- |
- |
- |
- |
- |
- |
- |
- |
- |
2E;22 |
ARG_0x4019_D |
RES_0x4019_D |
| SRR_KALIBRIERUNG_WERK |
0xA158 |
- |
Kalibrierung SRR für Inbetriebnahme im Werk |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
ARG_0xA158_R |
RES_0xA158_R |
| SRR_KALIBRIERUNG_HO |
0xA159 |
- |
SRR Kalibrierung für die Handelsorganisation |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
ARG_0xA159_R |
RES_0xA159_R |
| SRR_DAEMPFUNG_WERK |
0xA15A |
- |
SRR Dämpfungsmessung fürs Werk |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
ARG_0xA15A_R |
RES_0xA15A_R |
| SRR_DAEMPFUNG_HO |
0xA15B |
- |
Dämpfungsmessung SRR für die Handelsorganisation |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
ARG_0xA15B_R |
RES_0xA15B_R |
| SRR_DAEMPFUNG |
0xE2BB |
- |
Auslesen des Dämpfungswerts |
- |
- |
- |
- |
- |
- |
- |
- |
- |
22 |
- |
RES_0xE2BB_D |
| STATUS_SRR_READ_SNR_VALUE |
0xE3FA |
STAT_SNR_VALUE_WERT |
SNR Wert in dB |
dB |
- |
High |
unsigned int |
- |
1.0 |
100.0 |
0.0 |
- |
22 |
- |
- |
| EXTENDED_INTERNAL_INFO |
0xF002 |
- |
Output of ECU internal info |
- |
- |
- |
- |
- |
- |
- |
- |
- |
31 |
ARG_0xF002_R |
RES_0xF002_R |
| READHWMODIFICATIONINDEX |
0xF152 |
- |
Dieser Service kommt nur zum Einsatz, wenn es eine geringfügige Hardwareänderung an dem Steuergerät gegeben hat, die nicht zu einer Änderung der Sachnummer bzw. der Hardware SGBM-IDs geführt hat. Eine solche Änderung ist von außen nicht diagnostizierbar, daher wurde dieser Dienst dafür eingeführt. |
- |
- |
- |
- |
- |
- |
- |
- |
- |
22 |
- |
RES_0xF152_D |
| ACTIVE_DIAGNOSTIC_SESSION |
0xF186 |
STAT_ACTIVE_DIAGNOSTIC_SESSION |
activeDiagnosticSession |
0-n |
- |
High |
unsigned char |
RDBI_ADS_DOP |
- |
- |
- |
- |
22 |
- |
- |
STATUS_RAM_DATEN_SCHREIBEN_TAB
Dimensions: 4 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
Schreiben erfolgreich |
| 0x01 |
Schreiben fehlgeschlagen |
| 0x02 |
Schreiben läuft |
| 0x03 |
Schreiben noch nicht angestoßen (Routine nicht gestartet) |
TAB_RESET_REASON
Dimensions: 4 rows × 2 columns
| WERT |
TEXT |
| 0 |
StackOvl |
| 1 |
Hardware |
| 2 |
Assert (SW, Watchdog) |
| 0xFF |
Wert ungültig |
TAB_SRR_FEHLER_DETAIL
Dimensions: 6 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
Kein Fehler |
| 0x01 |
Kein Ziel gefunden |
| 0x02 |
Störeinflüsse in der Umgebung |
| 0x03 |
Unzureichende Sensorperformance |
| 0x04 |
Wert außerhalb zulässigen Bereichs |
| 0xFF |
Wert ungültig |
TAB_STATUS_ROUTINE
Dimensions: 7 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
Unbekannt |
| 0x01 |
Aktiv |
| 0x02 |
Erfolg |
| 0x03 |
Abbruch |
| 0x04 |
Fehler |
| 0x05 |
Phasenende |
| 0xFF |
Ungültig |
TAB_SUPPLIERINFO_FIELD
Dimensions: 64 rows × 2 columns
| WERT |
TEXT |
| 0x00 |
Wert 0 |
| 0x1 |
Wert 1 |
| 0x2 |
Wert 2 |
| 0x3 |
Wert 3 |
| 0x4 |
Wert 4 |
| 0x5 |
Wert 5 |
| 0x6 |
Wert 6 |
| 0x7 |
Wert 7 |
| 0x8 |
Wert 8 |
| 0x9 |
Wert 9 |
| 0xA |
Wert 10 |
| 0xB |
Wert 11 |
| 0xC |
Wert 12 |
| 0xD |
Wert 13 |
| 0xE |
Wert 14 |
| 0xF |
Wert 15 |
| 0x10 |
Wert 16 |
| 0x11 |
Wert 17 |
| 0x12 |
Wert 18 |
| 0x13 |
Wert 19 |
| 0x14 |
Wert 20 |
| 0x15 |
Wert 21 |
| 0x16 |
Wert 22 |
| 0x17 |
Wert 23 |
| 0x18 |
Wert 24 |
| 0x19 |
Wert 25 |
| 0x1A |
Wert 26 |
| 0x1B |
Wert 27 |
| 0x1C |
Wert 28 |
| 0x1D |
Wert 29 |
| 0x1E |
Wert 30 |
| 0x1F |
Wert 31 |
| 0x20 |
Wert 32 |
| 0x21 |
Wert 33 |
| 0x22 |
Wert 34 |
| 0x23 |
Wert 35 |
| 0x24 |
Wert 36 |
| 0x25 |
Wert 37 |
| 0x26 |
Wert 38 |
| 0x27 |
Wert 39 |
| 0x28 |
Wert 40 |
| 0x29 |
Wert 41 |
| 0x2A |
Wert 42 |
| 0x2B |
Wert 43 |
| 0x2C |
Wert 44 |
| 0x2D |
Wert 45 |
| 0x2E |
Wert 46 |
| 0x2F |
Wert 47 |
| 0x30 |
Wert 48 |
| 0x31 |
Wert 49 |
| 0x32 |
Wert 50 |
| 0x33 |
Wert 51 |
| 0x34 |
Wert 52 |
| 0x35 |
Wert 53 |
| 0x36 |
Wert 54 |
| 0x37 |
Wert 55 |
| 0x38 |
Wert 56 |
| 0x39 |
Wert 57 |
| 0x3A |
Wert 58 |
| 0x3B |
Wert 59 |
| 0x3C |
Wert 60 |
| 0x3D |
Wert 61 |
| 0x3E |
Wert 62 |
| 0xFF |
Wert ungültig |