ampt10.prg
INFO
| Field | Value |
|---|---|
| ECU | Top HIFI Verstärker |
| ORIGIN | BMW EI-41 JoannisToptsis |
| REVISION | 2.000 |
| AUTHOR | HarmanBecker EEA ChristianFenzl, HarmanBecker EEA ChristianKnot |
| COMMENT | - |
| PACKAGE | 1.49 |
| SPRACHE | deutsch |
Jobs
Index
- INFO - Information SGBD
- INITIALISIERUNG - Initialisierung und Kommunikationsparameter
- IDENT - Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
- FS_LESEN - Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
- FS_LESEN_DETAIL - Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
- FS_LOESCHEN - Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
- PRUEFSTEMPEL_LESEN - Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
- PRUEFSTEMPEL_SCHREIBEN - Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
- SVK_LESEN - Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
- STATUS_LESEN - Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
- STEUERN - Vorgeben eines Status UDS : $2E WriteDataByIdentifier
- SERIENNUMMER_LESEN - Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
- STEUERN_ROUTINE - Vorgeben eines Status UDS : $31 RoutineControl
- FS_SPERREN - Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
- IS_LESEN - Sekundaerer Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $22 ReadDataByIdentifierRequestServiceID UDS : $2000 DataIdentifier sekundaerer Fehlerspeicher Modus: Default
- IS_LESEN_DETAIL - sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $22 ReadDataByIdentifier UDS : $20 dataIdentifier UDS : $00 alle Info-Meldungen anschließend UDS : $20 dataIdentifier UDS : $nn Details zur Info-Meldung an der Position n Modus: Default
- IS_LOESCHEN - Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default
- HERSTELLINFO_LESEN - Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
- DIAGNOSE_AUFRECHT - Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
- DIAGNOSE_MODE - SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
- ENERGIESPARMODE - Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
- STATUS_ENERGIESPARMODE - Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
- STATUS_BETRIEBSMODE - Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default
- STEUERN_BETRIEBSMODE - Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default
- STEUERGERAETE_RESET - Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
- STATUS_VERSION_MOST_CONTROLLER - Return Version of MOST Controller
- STATUS_VERSORGUNGSSPANNUNG - Betriebsspannung am SG. Darstellung mit Millivolt-Auflösung.
- STATUS_WAKEUP_STATUS - Gibt an, ob das SG den MOST-Ring geweckt hat oder geweckt wurde.
- STATUS_ABILITY_TO_WAKE - Gibt an ob SG Most Ring wecken darf
- STATUS_AVERAGE_MESSAGE_RECEPTION_RATE - Liest die mittlere Nachrichtenabnahmerate des SGs während dieses Gerät geflasht wird, also in der ProgramminSession Auslesbar muss der Status jederzeit sein
- STATUS_FOT_TEMPERATUR - Temperatur am FOT
- STEUERN_SENSOR_TEMP - Simulates the temperature of a definite sensor.
- STEUERN_WATCHDOG_TRIGGER_STOP - Unterbindet das regelmäßige Rücksetzen des Applikations-Watchdogs nach ARG_TIME_WATCHDOG Sekunden. Wenn ARG_TIME_WATCHDOG nicht angegeben wird, wird der Wert 0 benutzt.
- STATUS_SENSOR_TEMP - Returns the temperature of the desired sensor (no matter if the temperature is currently being simulated or not).
- STEUERN_ROE_STOP - Temporaeres Deaktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $00 Stop $02 (EventWindowTime) gültig für LH Diagnosemaster V9 oder früher. (pre 35up)
- STATUS_ROE_REPORT - Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS: $86 ResponseOnEvent $04 report activated events [$02 eventWindowTime - infinite (nur 35up)] 35up: LH Diagnosemaster V11 oder höher pre35up: LH Diagnosemaster V6 - V9
- STEUERN_ROE_START - Temporaeres Aktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $05 Start $02 (EventWindowTime) gültig für LH Diagnosemaster V9 oder früher. (pre 35up)
- STEUERN_ROE_PERSISTENT_STOP - Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
- STEUERN_ROE_PERSISTENT_START - Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
- CPS_LESEN - Codierpruefstempel lesen UDS : $22 ReadDataByIdentifier UDS : $37FE DataIdentifier Codierpruefstempel Modus: Default
- DIAG_SESSION_LESEN - Aktive Diagnose-Session auslesen UDS : $22 ReadDataByIdentifier UDS : $F186 ActiveDiagnosticSession Modus: Default
- FLASH_TP_LESEN - Flash Timing Parameter auslesen UDS : $22 ReadDataByIdentifier UDS : $2504 FlashTimingParameter Modus: Default
- PROG_ZAEHLER_LESEN - Programmierzaehler lesen UDS : $22 ReadDataByIdentifier UDS : $2502 ProgrammingCounter Modus: Default
- PROG_MAX_LESEN - Anzahl der maximal möglichen Programmiervorgänge auslesen UDS : $22 ReadDataByIdentifier UDS : $2503 ProgrammingCounter Modus: Default
- STEUERN_HARMAN_SW_VERSION - Read SW Versions UDS: $31 RoutineControl $01 startRoutine $F0 00 RoutineIdentifier PM Mode $FF Developer Functions $20 Version $xx Sort $00 Get Status $0D PM Mode Endmarker HARMAN Version: xx.yy.zz xx = Major yy = Minor zz = Bugfix
INFO
Information SGBD
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| ECU | string | Steuergerät im Klartext |
| ORIGIN | string | Steuergeräte-Verantwortlicher |
| REVISION | string | Versions-Nummer |
| AUTHOR | string | Namen aller Autoren |
| COMMENT | string | wichtige Hinweise |
| PACKAGE | string | Include-Paket-Nummer |
| SPRACHE | string | deutsch, english |
INITIALISIERUNG
Initialisierung und Kommunikationsparameter
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| DONE | int | 1, wenn Okay |
IDENT
Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| ID_SG_ADR | long | Steuergeraeteadresse |
| ID_SGBD_INDEX | long | Index zur Erkennung der SG-Variante |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FS_LESEN
Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| IGNORIERE_EREIGNIS_DTC | string | 'IGNORIERE_EREIGNIS_DTC': Alle Ereignis DTC-Fehlereinträge werden ignoriert sonst: alle Fehlereinträge werden ausgegeben |
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FS_LESEN_DETAIL
Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| F_CODE | long | gewaehlter Fehlercode |
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_HFK | int | Haeufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf |
| F_HLZ | int | Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Heilungsszaehler |
| F_UEBERLAUF | int | 0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers |
| F_FEHLERKLASSE_NR | int | 0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich ! |
| F_FEHLERKLASSE_TEXT | string | Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT |
| F_UW_ANZ | int | Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung |
| F_UW_KM | long | Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht |
| F_UW_ZEIT | long | Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_SAE_CODE | unsigned int | Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD |
| F_SAE_CODE_STRING | string | 5 stelliger Text in der Form 'Sxxxx' |
| F_SAE_CODE_TEXT | string | Text zu F_SAE_CODE |
| _RESPONSE_SNAPSHOT | binary | Hex-Antwort von SG |
| _RESPONSE_EXTENDED_DATA | binary | Hex-Antwort von SG |
| _RESPONSE_SEVERITY | binary | Hex-Antwort von SG |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
FS_LOESCHEN
Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| F_CODE | long | 0x??????: Angabe eines einzelnen Fehlers Default: 0xFFFFFF: alle Fehler |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PRUEFSTEMPEL_LESEN
Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| BYTE1 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE2 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE3 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PRUEFSTEMPEL_SCHREIBEN
Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| BYTE1 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE2 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE3 | int | Bereich: 0-255 bzw. 0x00-0xFF |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
SVK_LESEN
Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| SVK | string | table SVK_ID BEZEICHNUNG WERT default SVK_AKTUELL |
Results
| Name | Type | Comment |
|---|---|---|
| PROG_TEST | int | Programmierabhaengigkeiten (ProgrammingDependenciesChecked) 1: IO : Signaturpruefung und ProgrammingDependenciesCheck erfolgreich 2: NIO: mindestens eine SWE fehlerhaft oder ProgrammingDependenciesCheck nicht durchgefuehrt 3: NIO: mindestens eine SWE passt nicht mit einer HWE zusammen 4: NIO: mindestens eine SWE passt nicht mit einer anderen SWE zusammen sonst: reserviert |
| ANZAHL_EINHEITEN | int | Anzahl der xWEn |
| PROG_DATUM | string | Programmierdatum (DD.MM.YY) |
| PROG_KM | long | KM-Stand bei Programmierung (10 KM bis 655350 KM) Inkrement sind 10 KM -1: KM-Stand wird nicht unterstuetzt |
| PROZESSKLASSE_WERT | int | table Prozessklassen WERT dezimale Angabe der Prozessklasse |
| PROZESSKLASSE_TEXT | string | table Prozessklassen BEZEICHNUNG Text-Angabe der Prozessklasse |
| PROZESSKLASSE_KURZTEXT | string | table Prozessklassen PROZESSKLASSE Text-Angabe des Prozessklassenkurztextes |
| SGBM_IDENTIFIER | string | Angabe SGBM-ID der Prozessklasse |
| VERSION | string | Angabe der Version der Prozessklasse |
| SGBM_ID | string | Angabe von Prozessklasse, SGBM-Identifier, Version |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_LESEN
Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Es muss mindestens ein Argument übergeben werden Es wird das zugehörige result erzeugt table SG_Funktionen ARG ID RESULTNAME RES_TABELLE ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN
Vorgeben eines Status UDS : $2E WriteDataByIdentifier
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Siehe table SG_Funktionen ARG ID LABEL ARG_TABELLE |
| WERT | string | Es muss mindestens ein Argument übergeben werden Argumente siehe table SG_Funktionen ARG ID ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
SERIENNUMMER_LESEN
Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| SERIENNUMMER | string | Seriennummer des Steuergeraets |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROUTINE
Vorgeben eines Status UDS : $31 RoutineControl
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Siehe table SG_Funktionen ARG ID RES_TABELLE ARG_TABELLE |
| STEUERPARAMETER | string | 'STR' = startRoutine 'STPR' = stopRoutine 'RRR' = requestRoutineResults |
| WERT | string | Argumente siehe table SG_Funktionen ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FS_SPERREN
Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| SPERREN | string | "ja" -> Fehlerspeicher sperren "nein" -> Fehlerspeicher freigeben table DigitalArgument TEXT Default: "ja" |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
IS_LESEN
Sekundaerer Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $22 ReadDataByIdentifierRequestServiceID UDS : $2000 DataIdentifier sekundaerer Fehlerspeicher Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
IS_LESEN_DETAIL
sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $22 ReadDataByIdentifier UDS : $20 dataIdentifier UDS : $00 alle Info-Meldungen anschließend UDS : $20 dataIdentifier UDS : $nn Details zur Info-Meldung an der Position n Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| F_CODE | long | gewaehlter Infocode Wenn dieser Parameter angegeben wird, wird die Position automatisch ermittelt. Es darf dann nicht argument F_POS angegeben werden |
| F_POS | int | gewaehlter Eintrag Wenn dieser Parameter angegeben wird, wird die Position benutzt. Wertebereich 1 - 255 Es darf dann nicht argument F_CODE angegeben werden |
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_HFK | int | Haeufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf |
| F_HLZ | int | Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Heilungsszaehler |
| F_UEBERLAUF | int | 0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers |
| F_FEHLERKLASSE_NR | int | 0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich ! |
| F_FEHLERKLASSE_TEXT | string | Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT |
| F_UW_ANZ | int | Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung |
| F_UW_KM | long | Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht |
| F_UW_ZEIT | long | Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_SAE_CODE | unsigned int | Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD |
| F_SAE_CODE_STRING | string | 5 stelliger Text in der Form 'Sxxxx' |
| F_SAE_CODE_TEXT | string | Text zu F_SAE_CODE |
| _RESPONSE_2000 | binary | Hex-Antwort von SG |
| _RESPONSE_200X | binary | Hex-Antwort von SG |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
IS_LOESCHEN
Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
HERSTELLINFO_LESEN
Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| ID_LIEF_NR | long | Lieferantennummer 0xFFFFFF, falls nicht vorhanden |
| ID_LIEF_TEXT | string | Text zu ID_LIEF_NR table Lieferanten LIEF_TEXT unbekannter Hersteller, falls nicht vorhanden |
| ID_DATUM | string | Herstelldatum (DD.MM.YY) |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
| _REQUEST_2 | binary | Hex-Auftrag an SG |
| _RESPONSE_2 | binary | Hex-Antwort von SG |
DIAGNOSE_AUFRECHT
Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| SG_ANTWORT | string | "ja" -> SG soll antworten "nein" -> SG soll nicht antworten table DigitalArgument TEXT Default: SG soll antworten |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
DIAGNOSE_MODE
SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
Arguments
| Name | Type | Comment |
|---|---|---|
| MODE | string | gewuenschter Diagnose-Modus table DiagMode MODE MODE_TEXT Defaultwert: DEFAULT (DefaultMode) |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
ENERGIESPARMODE
Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
Arguments
| Name | Type | Comment |
|---|---|---|
| MODE | int | 0x00: Normalmode 0x01: Fertigungsmode 0x02: Transportmode 0x03: Flashmode |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_ENERGIESPARMODE
Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_ENERGIESPARMODE_WERT | int | Ausgabe des Energiesparmodes 0: Kein Energiesparmode gesetzt 1: Produktionsmode gesetzt 2: Transportmode gesetzt 3: Flashmode gesetzt -1: Mode ungueltig |
| STAT_ENERGIESPARMODE_TEXT | string | Text zu STAT_ENERGIESPARMODE_WERT |
| STAT_PRODUKTIONSMODE_EIN | int | 0: Produktionsmode nicht aktiv 1: Produktionsmode aktiv |
| STAT_TRANSPORTMODE_EIN | int | 0: Transportmode nicht aktiv 1: Transportmode aktiv |
| STAT_FLASHMODE_EIN | int | 0: Flashmode nicht aktiv 1: Flashmode aktiv |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_BETRIEBSMODE
Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_BETRIEBSMODE_WERT | int | Aktueller Betriebsmode table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle) |
| STAT_BETRIEBSMODE_TEXT | string | Textausgabe STAT_BETRIEBSMODE_WERT table Betriebsmode TEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_BETRIEBSMODE
Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| BETRIEBSMODE | int | Betriebsmode setzen table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle) |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERGERAETE_RESET
Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_VERSION_MOST_CONTROLLER
Return Version of MOST Controller
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_TRANSCEIVER_VERSION | string | Transceiver Version Format DDMMYY |
| STAT_NETSERVICES_VERSION | string | 3 Bytes Netservices Version |
| STAT_NETSERVICES_REVISION | string | 4 Byte Netservices Revision |
| JOB_STATUS | string | "OKAY", wenn fehlerfrei |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_VERSORGUNGSSPANNUNG
Betriebsspannung am SG. Darstellung mit Millivolt-Auflösung.
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_MILLI_VOLT_WERT | unsigned int | Spannung in milliVolt |
| STAT_MILLI_VOLT_EINH | string | unit of the result |
| JOB_STATUS | string | "OKAY", wenn fehlerfrei |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_WAKEUP_STATUS
Gibt an, ob das SG den MOST-Ring geweckt hat oder geweckt wurde.
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_WAKEUP_STATUS | int | 0 = nicht initialisiert, 1 = SG hat geweckt, 2= SG wurde geweckt from table TWakeupStatus WERT |
| STAT_WAKEUP_STATUS_TEXT | string | 0 = nicht initialisiert, 1 = SG hat geweckt, 2= SG wurde geweckt from table TWakeupStatus TEXT |
| JOB_STATUS | string | "OKAY", wenn fehlerfrei |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_ABILITY_TO_WAKE
Gibt an ob SG Most Ring wecken darf
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_ABILITY_TO_WAKE | int | 0 = off, 1 = on, 2= critical ("critical" ist in Most Specs definiert wird aber praktisch nicht benutzt) |
| STAT_ABILITY_TO_WAKE_TEXT | string | 0 = off, 1 = on, 2= critical ("critical" ist in Most Specs definiert wird aber praktisch nicht benutzt) |
| JOB_STATUS | string | "OKAY", wenn fehlerfrei |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_AVERAGE_MESSAGE_RECEPTION_RATE
Liest die mittlere Nachrichtenabnahmerate des SGs während dieses Gerät geflasht wird, also in der ProgramminSession Auslesbar muss der Status jederzeit sein
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_MSG_CMS_SYNC_WERT | unsigned int | Mittl. Nachrichtenabnahmerate des Kontrollkanals [0-1000] |
| STAT_MSG_CMS_ASYNC_WERT | unsigned int | Mittl. Nachrichtenabnahmerate des async. Kanals. Sollte dieses Gerät nicht Async geflasht werden muss dieser Parameter auf 0 gesetzt sein [0-10000] |
| JOB_STATUS | string | "OKAY", wenn fehlerfrei |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_FOT_TEMPERATUR
Temperatur am FOT
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_FOT_TEMP_CELSIUS | char | Temperatur am FOT des SG in Celsius -128 C bis +127 C hierbei -128 C bedeutet ungültig (0xFF) |
| STAT_FOT_TEMP_FAHRENHEIT | real | Temperatur am FOT des SG in Fahrenheit -196.6 F bis +260.6 F hierbei bedeutet -198.4 F ungültig ( -128 C) Dieses this result is calculated inside the SGBD-Job Fahrenheit = (( Celsius × 9 ) / 5 ) + 32 |
| JOB_STATUS | string | "OKAY", wenn fehlerfrei |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_SENSOR_TEMP
Simulates the temperature of a definite sensor.
Arguments
| Name | Type | Comment |
|---|---|---|
| ARG_SENSOR | unsigned char | Sensor for which the temperature must be simulated |
| ARG_TEMPERATURE | int | Temperature that must be simulated |
| ARG_DURATION | unsigned int | Duration of the temperature simulation |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | "OKAY", wenn fehlerfrei |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_WATCHDOG_TRIGGER_STOP
Unterbindet das regelmäßige Rücksetzen des Applikations-Watchdogs nach ARG_TIME_WATCHDOG Sekunden. Wenn ARG_TIME_WATCHDOG nicht angegeben wird, wird der Wert 0 benutzt.
Arguments
| Name | Type | Comment |
|---|---|---|
| ARG_TIME_WATCHDOG | unsigned int | Beschreibung: z.B. ARG_TIME_WATCHDOG = 4 bedeutet Abschalten des Watchdog-Triggers nach 4 Sekunden. nur positiven Zahlen und die 0. Skalierung: 1 entspricht 1 Sekunde |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | "OKAY", wenn fehlerfrei |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_SENSOR_TEMP
Returns the temperature of the desired sensor (no matter if the temperature is currently being simulated or not).
Arguments
| Name | Type | Comment |
|---|---|---|
| ARG_SENSOR | unsigned char | Sensor for which the temperature must be returned |
Results
| Name | Type | Comment |
|---|---|---|
| STAT_TEMPERATURE_WERT | int | Temperature of the selected sensor |
| STAT_DURATION_WERT | unsigned int | Remaining duration for the simulated temperature |
| JOB_STATUS | string | "OKAY", wenn fehlerfrei |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_STOP
Temporaeres Deaktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $00 Stop $02 (EventWindowTime) gültig für LH Diagnosemaster V9 oder früher. (pre 35up)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_ROE_REPORT
Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS: $86 ResponseOnEvent $04 report activated events [$02 eventWindowTime - infinite (nur 35up)] 35up: LH Diagnosemaster V11 oder höher pre35up: LH Diagnosemaster V6 - V9
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_ROE_AKTIV | char | 0x00 = Aktive Fehlermeldung deaktiviert 0x01 = Aktive Fehlermeldung aktiviert 0xFF = Status der aktiven Fehlermeldung nicht feststellbar |
| STAT_ROE_AKTIV_TEXT | string | Interpretation von STAT_ROE_AKTIV table UDS_TAB_ROE_AKTIV TEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_START
Temporaeres Aktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $05 Start $02 (EventWindowTime) gültig für LH Diagnosemaster V9 oder früher. (pre 35up)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_PERSISTENT_STOP
Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_PERSISTENT_START
Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime) gültig für LH Diagnosemaster V6 - V12 (Stand 2013)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
CPS_LESEN
Codierpruefstempel lesen UDS : $22 ReadDataByIdentifier UDS : $37FE DataIdentifier Codierpruefstempel Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| CPS | string | Codierpruefstempel 7-stellig |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
DIAG_SESSION_LESEN
Aktive Diagnose-Session auslesen UDS : $22 ReadDataByIdentifier UDS : $F186 ActiveDiagnosticSession Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| DIAG_SESSION_WERT | int | Diagnose-Session (1 Byte) |
| DIAG_SESSION_TEXT | string | Diagnose-Session als Text |
| DIAG_DETAIL_WERT | int | Details zur Diagnose-Session (1 Byte) |
| DIAG_DETAIL_TEXT | string | Details zur Diagnose-Session als Text |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FLASH_TP_LESEN
Flash Timing Parameter auslesen UDS : $22 ReadDataByIdentifier UDS : $2504 FlashTimingParameter Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| FLASH_LOESCHEN | int | EraseMemoryTime (2 Byte) |
| FLASH_TEST | int | CheckMemoryTime (2 Byte) |
| FLASH_BOOT | int | BootloaderInstallationTime (2 Byte) |
| FLASH_AUTHENT | int | AuthenticationTime (2 Byte) |
| FLASH_RESET | int | ResetTime (2 Byte) |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PROG_ZAEHLER_LESEN
Programmierzaehler lesen UDS : $22 ReadDataByIdentifier UDS : $2502 ProgrammingCounter Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| PROG_ZAEHLER_STATUS_WERT | int | Status, wie oft das SG programmierbar ist |
| PROG_ZAEHLER_STATUS_TEXT | string | Status, wie oft das SG programmierbar ist |
| PROG_ZAEHLER | int | Programmierzaehler |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PROG_MAX_LESEN
Anzahl der maximal möglichen Programmiervorgänge auslesen UDS : $22 ReadDataByIdentifier UDS : $2503 ProgrammingCounter Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| PROG_MAX | long | maximal mögliche Programmiervorgänge Sonderfall 0xFFFF: Anzahl der Programmiervorgänge unbegrenzt |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_HARMAN_SW_VERSION
Read SW Versions UDS: $31 RoutineControl $01 startRoutine $F0 00 RoutineIdentifier PM Mode $FF Developer Functions $20 Version $xx Sort $00 Get Status $0D PM Mode Endmarker HARMAN Version: xx.yy.zz xx = Major yy = Minor zz = Bugfix
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| SW_VERSION_CU | string | Controller Urloader Version xx.yy.zz xx = Major yy = Minor zz = Bugfix |
| SW_VERSION_CF | string | Controller Flasher Version xx.yy.zz xx = Major yy = Minor zz = Bugfix |
| SW_VERSION_CA | string | Controller Audio Application xx.yy.zz xx = Major yy = Minor zz = Bugfix |
| SW_VERSION_CB | string | Controller H/B BIOS Version xx.yy.zz xx = Major yy = Minor zz = Bugfix |
| SW_VERSION_DU | string | DSP Urloader Version xx.yy.zz xx = Major yy = Minor zz = Bugfix |
| SW_VERSION_DF | string | DSP Flasher Version xx.yy.zz xx = Major yy = Minor zz = Bugfix |
| SW_VERSION_DA | string | DSP Audio Application Version xx.yy.zz xx = Major yy = Minor zz = Bugfix |
| SW_VERSION_DB | string | DSP H/B BIOS Version xx.yy.zz xx = Major yy = Minor zz = Bugfix |
| SW_VERSION_DS | string | DSP DataSet Version xx.yy.zz xx = Major yy = Minor zz = Bugfix |
| SW_VERSION_MST | string | INIC firmware Version xx.yy.zz xx = Major yy = Minor zz = Bugfix |
| SW_VERSION_NS | string | MOST NetServices Version xx.yy.zz xx = Major yy = Minor zz = Bugfix |
| SW_VERSION_HW | string | INIC Hardware Version xx xx = Major |
| SW_VERSION_CS | string | INIC ConfigString Version xx.yy.zz xx = Major yy = Minor zz = Bugfix |
| SW_VERSION_P | string | Lattice Power Controller Version xx.yy.zz xx = Major yy = Minor zz = Bugfix |
| _REQUEST_CU | binary | Hex-Auftrag an SG |
| _RESPONSE_CU | binary | Hex-Antwort von SG |
| _REQUEST_CF | binary | Hex-Auftrag an SG |
| _RESPONSE_CF | binary | Hex-Antwort von SG |
| _REQUEST_CA | binary | Hex-Auftrag an SG |
| _RESPONSE_CA | binary | Hex-Antwort von SG |
| _REQUEST_CB | binary | Hex-Auftrag an SG |
| _RESPONSE_CB | binary | Hex-Antwort von SG |
| _REQUEST_DU | binary | Hex-Auftrag an SG |
| _RESPONSE_DU | binary | Hex-Antwort von SG |
| _REQUEST_DF | binary | Hex-Auftrag an SG |
| _RESPONSE_DF | binary | Hex-Antwort von SG |
| _REQUEST_DA | binary | Hex-Auftrag an SG |
| _RESPONSE_DA | binary | Hex-Antwort von SG |
| _REQUEST_DB | binary | Hex-Auftrag an SG |
| _RESPONSE_DB | binary | Hex-Antwort von SG |
| _REQUEST_DS | binary | Hex-Auftrag an SG |
| _RESPONSE_DS | binary | Hex-Antwort von SG |
| _REQUEST_MST | binary | Hex-Auftrag an SG |
| _RESPONSE_MST | binary | Hex-Antwort von SG |
| _REQUEST_P | binary | Hex-Auftrag an SG |
| _RESPONSE_P | binary | Hex-Antwort von SG |
Tables
Index
- JOBRESULT (76 × 2)
- LIEFERANTEN (137 × 2)
- FARTTEXTE (35 × 2)
- DIGITALARGUMENT (17 × 2)
- PROZESSKLASSEN (26 × 3)
- SVK_ID (65 × 2)
- DTCEXTENDEDDATARECORDNUMBER (5 × 3)
- DTCSNAPSHOTIDENTIFIER (5 × 9)
- FEHLERKLASSE (5 × 2)
- DIAGMODE (12 × 3)
- IARTTEXTE (18 × 2)
- UDS_TAB_ROE_AKTIV (3 × 2)
- TFBLOCKIDTEXTE (85 × 2)
- TWAKEUPSTATUS (3 × 3)
- ARG_0XA001_R (3 × 14)
- ARG_0XA06F_R (1 × 14)
- ARG_0XD003_D (1 × 12)
- ARG_0XD05B_D (2 × 12)
- BETRIEBSMODE (2 × 3)
- DM_TAB_ROE_ACTIVATED_DOP (2 × 2)
- ENERGIESPARMODE_DOP (4 × 2)
- EXTENDED_ENERGY_MODE_DOP (16 × 2)
- FDETAILSTRUKTUR (6 × 2)
- FEHLERKLASSE_DOP (4 × 2)
- FORTTEXTE (21 × 3)
- FUMWELTTEXTE (13 × 9)
- IDETAILSTRUKTUR (4 × 2)
- IORTTEXTE (11 × 3)
- IUMWELTTEXTE (13 × 9)
- JOBRESULTEXTENDED (1 × 2)
- LEISTUNGSZUSTAND (4 × 2)
- PROG_DEP_DOP (6 × 2)
- RDBI_ADS_DOP (8 × 2)
- RDBI_PC_PCS_DOP (3 × 2)
- RDTCI_LEV_DOP (9 × 2)
- RES_0XA06F_R (1 × 13)
- RES_0XD003_D (1 × 10)
- RES_0XD026_D (6 × 10)
- RES_0XD05B_D (2 × 10)
- ROE_EWT_DOP (1 × 2)
- SG_FUNKTIONEN (6 × 16)
- SVK_VERSION_DOP (2 × 2)
- TAB_ABILITY_TO_WAKE_DOP (3 × 2)
- TAB_AMP_LEISTUNGSZUSTAND (4 × 2)
- TAB_SENSOR_TEMP_DOP (2 × 2)
- TAB_WAKE_UP_STATUS_DOP (3 × 2)
- TAUDIOKANAL (26 × 2)
- TKEYNR (16 × 2)
- TRADONLEAD (3 × 2)
JOBRESULT
Dimensions: 76 rows × 2 columns
| SB | STATUS_TEXT |
|---|---|
| 0x10 | ERROR_ECU_GENERAL_REJECT |
| 0x11 | ERROR_ECU_SERVICE_NOT_SUPPORTED |
| 0x12 | ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED |
| 0x13 | ERROR_ECU_INCORRECT_MESSAGE_LENGTH_OR_INVALID_FORMAT |
| 0x14 | ERROR_ECU_RESPONSE_TOO_LONG |
| 0x21 | ERROR_ECU_BUSY_REPEAT_REQUEST |
| 0x22 | ERROR_ECU_CONDITIONS_NOT_CORRECT |
| 0x24 | ERROR_ECU_REQUEST_SEQUENCE_ERROR |
| 0x25 | ERROR_ECU_NO_RESPONSE_FROM_SUBNET_COMPONENT |
| 0x26 | ERROR_ECU_FAILURE_PREVENTS_EXECUTION_OF_REQUESTED_ACTION |
| 0x31 | ERROR_ECU_REQUEST_OUT_OF_RANGE |
| 0x33 | ERROR_ECU_SECURITY_ACCESS_DENIED |
| 0x35 | ERROR_ECU_INVALID_KEY |
| 0x36 | ERROR_ECU_EXCEED_NUMBER_OF_ATTEMPTS |
| 0x37 | ERROR_ECU_REQUIRED_TIME_DELAY_NOT_EXPIRED |
| 0x70 | ERROR_ECU_UPLOAD_DOWNLOAD_NOT_ACCEPTED |
| 0x71 | ERROR_ECU_TRANSFER_DATA_SUSPENDED |
| 0x72 | ERROR_ECU_GENERAL_PROGRAMMING_FAILURE |
| 0x73 | ERROR_ECU_WRONG_BLOCK_SEQUENCE_COUNTER |
| 0x78 | ERROR_ECU_REQUEST_CORRECTLY_RECEIVED__RESPONSE_PENDING |
| 0x7E | ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED_IN_ACTIVE_SESSION |
| 0x7F | ERROR_ECU_SERVICE_NOT_SUPPORTED_IN_ACTIVE_SESSION |
| 0x81 | ERROR_ECU_RPM_TOO_HIGH |
| 0x82 | ERROR_ECU_RPM_TOO_LOW |
| 0x83 | ERROR_ECU_ENGINE_IS_RUNNING |
| 0x84 | ERROR_ECU_ENGINE_IS_NOT_RUNNING |
| 0x85 | ERROR_ECU_ENGINE_RUN_TIME_TOO_LOW |
| 0x86 | ERROR_ECU_TEMPERATURE_TOO_HIGH |
| 0x87 | ERROR_ECU_TEMPERATURE_TOO_LOW |
| 0x88 | ERROR_ECU_VEHICLE_SPEED_TOO_HIGH |
| 0x89 | ERROR_ECU_VEHICLE_SPEED_TOO_LOW |
| 0x8A | ERROR_ECU_THROTTLE_PEDAL_TOO_HIGH |
| 0x8B | ERROR_ECU_THROTTLE_PEDAL_TOO_LOW |
| 0x8C | ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_NEUTRAL |
| 0x8D | ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_GEAR |
| 0x8F | ERROR_ECU_BRAKE_SWITCH_NOT_CLOSED |
| 0x90 | ERROR_ECU_SHIFTER_LEVER_NOT_IN_PARK |
| 0x91 | ERROR_ECU_TORQUE_CONVERTER_CLUTCH_LOCKED |
| 0x92 | ERROR_ECU_VOLTAGE_TOO_HIGH |
| 0x93 | ERROR_ECU_VOLTAGE_TOO_LOW |
| ?00? | OKAY |
| ?01? | ERROR_ECU_NO_RESPONSE |
| ?02? | ERROR_ECU_INCORRECT_LEN |
| ?03? | ERROR_ECU_INCORRECT_RESPONSE_ID |
| ?04? | ERROR_ECU_TA_RESPONSE_NOT_SA_REQUEST |
| ?05? | ERROR_ECU_SA_RESPONSE_NOT_TA_REQUEST |
| ?06? | ERROR_ECU_RESPONSE_INCORRECT_DATA_IDENTIFIER |
| ?07? | ERROR_ECU_RESPONSE_TOO_MUCH_DATA |
| ?08? | ERROR_ECU_RESPONSE_TOO_LESS_DATA |
| ?09? | ERROR_ECU_RESPONSE_VALUE_OUT_OF_RANGE |
| ?0A? | ERROR_TABLE |
| ?10? | ERROR_F_CODE |
| ?12? | ERROR_INTERPRETATION |
| ?13? | ERROR_F_POS |
| ?14? | ERROR_ECU_RESPONSE_INCORRECT_IO_CONTROL_PARAMETER |
| ?15? | ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_CONTROL_TYPE |
| ?16? | ERROR_ECU_RESPONSE_INCORRECT_SUB_FUNCTION |
| ?17? | ERROR_ECU_RESPONSE_INCORRECT_DYNAMICALLY_DEFINED_DATA_IDENTIFIER |
| ?18? | ERROR_ECU_RESPONSE_NO_STRING_END_CHAR |
| ?19? | ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_IDENTIFIER |
| ?1A? | ERROR_ECU_RESPONSE_INCORRECT_RESET_TYPE |
| ?1B? | ERROR_ECU_RESPONSE_INCORRECT_SERIAL_NUMBER_FORMAT |
| ?1C? | ERROR_ECU_RESPONSE_INCORRECT_DTC_BY_STATUS_MASK |
| ?1D? | ERROR_ECU_RESPONSE_INCORRECT_DTC_STATUS_AVAILABILITY_MASK |
| ?1E? | ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_CONTROL_IDENTIFIER |
| ?50? | ERROR_BYTE1 |
| ?51? | ERROR_BYTE2 |
| ?52? | ERROR_BYTE3 |
| ?60? | ERROR_VERIFY |
| ?61? | ERROR_ECU_RESPONSE_ZGW |
| ?62? | ERROR_ECU_RESPONSE_BACKUP |
| ?70? | ERROR_CALID_CVN_INCORRECT_LEN |
| ?80? | ERROR_SVK_INCORRECT_LEN |
| ?81? | ERROR_SVK_INCORRECT_FINGERPRINT |
| ?F0? | ERROR_ARGUMENT |
| 0xXY | ERROR_ECU_UNKNOWN_NEGATIVE_RESPONSE |
LIEFERANTEN
Dimensions: 137 rows × 2 columns
| LIEF_NR | LIEF_TEXT |
|---|---|
| 0x000001 | Reinshagen => Delphi |
| 0x000002 | Kostal |
| 0x000003 | Hella |
| 0x000004 | Siemens |
| 0x000005 | Eaton |
| 0x000006 | UTA |
| 0x000007 | Helbako |
| 0x000008 | Bosch |
| 0x000009 | Loewe => Lear |
| 0x000010 | VDO |
| 0x000011 | Valeo |
| 0x000012 | MBB |
| 0x000013 | Kammerer |
| 0x000014 | SWF |
| 0x000015 | Blaupunkt |
| 0x000016 | Philips |
| 0x000017 | Alpine |
| 0x000018 | Continental Teves |
| 0x000019 | Elektromatik Suedafrika |
| 0x000020 | Becker |
| 0x000021 | Preh |
| 0x000022 | Alps |
| 0x000023 | Motorola |
| 0x000024 | Temic |
| 0x000025 | Webasto |
| 0x000026 | MotoMeter |
| 0x000027 | Delphi PHI |
| 0x000028 | DODUCO => BERU |
| 0x000029 | DENSO |
| 0x000030 | NEC |
| 0x000031 | DASA |
| 0x000032 | Pioneer |
| 0x000033 | Jatco |
| 0x000034 | Fuba |
| 0x000035 | UK-NSI |
| 0x000036 | AABG |
| 0x000037 | Dunlop |
| 0x000038 | Sachs |
| 0x000039 | ITT |
| 0x000040 | FTE |
| 0x000041 | Megamos |
| 0x000042 | TRW |
| 0x000043 | Wabco |
| 0x000044 | ISAD Electronic Systems |
| 0x000045 | HEC (Hella Electronics Corporation) |
| 0x000046 | Gemel |
| 0x000047 | ZF |
| 0x000048 | GMPT |
| 0x000049 | Harman Kardon |
| 0x000050 | Remes |
| 0x000051 | ZF Lenksysteme |
| 0x000052 | Magneti Marelli |
| 0x000053 | Borg Instruments |
| 0x000054 | GETRAG |
| 0x000055 | BHTC (Behr Hella Thermocontrol) |
| 0x000056 | Siemens VDO Automotive |
| 0x000057 | Visteon |
| 0x000058 | Autoliv |
| 0x000059 | Haberl |
| 0x000060 | Magna Steyr |
| 0x000061 | Marquardt |
| 0x000062 | AB-Elektronik |
| 0x000063 | Siemens VDO Borg |
| 0x000064 | Hirschmann Electronics |
| 0x000065 | Hoerbiger Electronics |
| 0x000066 | Thyssen Krupp Automotive Mechatronics |
| 0x000067 | Gentex GmbH |
| 0x000068 | Atena GmbH |
| 0x000069 | Magna-Donelly |
| 0x000070 | Koyo Steering Europe |
| 0x000071 | NSI B.V |
| 0x000072 | AISIN AW CO.LTD |
| 0x000073 | Shorlock |
| 0x000074 | Schrader |
| 0x000075 | BERU Electronics GmbH |
| 0x000076 | CEL |
| 0x000077 | Audio Mobil |
| 0x000078 | rd electronic |
| 0x000079 | iSYS RTS GmbH |
| 0x000080 | Westfalia Automotive GmbH |
| 0x000081 | Tyco Electronics |
| 0x000082 | Paragon AG |
| 0x000083 | IEE S.A |
| 0x000084 | TEMIC AUTOMOTIVE of NA |
| 0x000085 | AKsys GmbH |
| 0x000086 | META System |
| 0x000087 | Hülsbeck & Fürst GmbH & Co KG |
| 0x000088 | Mann & Hummel Automotive GmbH |
| 0x000089 | Brose Fahrzeugteile GmbH & Co |
| 0x000090 | Keihin |
| 0x000091 | Vimercati S.p.A. |
| 0x000092 | CRH |
| 0x000093 | TPO Display Corp. |
| 0x000094 | KÜSTER Automotive Control |
| 0x000095 | Hitachi Automotive |
| 0x000096 | Continental Automotive |
| 0x000097 | TI-Automotive |
| 0x000098 | Hydro |
| 0x000099 | Johnson Controls |
| 0x00009A | Takata- Petri |
| 0x00009B | Mitsubishi Electric B.V. (Melco) |
| 0x00009C | Autokabel |
| 0x00009D | GKN-Driveline |
| 0x00009E | Zollner Elektronik AG |
| 0x00009F | PEIKER acustics GmbH |
| 0x0000A0 | Bosal-Oris |
| 0x0000A1 | Cobasys |
| 0x0000A2 | Lighting Reutlingen GmbH |
| 0x0000A3 | CONTI VDO |
| 0x0000A4 | ADC Automotive Distance Control Systems GmbH |
| 0x0000A5 | Funkwerk Dabendorf GmbH |
| 0x0000A6 | Lame |
| 0x0000A7 | Magna/Closures |
| 0x0000A8 | Wanyu |
| 0x0000A9 | Thyssen Krupp Presta |
| 0x0000AA | ArvinMeritor |
| 0x0000AB | Kongsberg Automotive GmbH |
| 0x0000AC | SMR Automotive Mirrors |
| 0x0000AD | So.Ge.Mi. |
| 0x0000AE | MTA |
| 0x0000AF | Alfmeier |
| 0x0000B0 | ELTEK VALERE DEUTSCHLAND GMBH |
| 0x0000B1 | Omron Automotive Electronics Europe Group |
| 0x0000B2 | ASK |
| 0x0000B3 | CML Innovative Technologies GmbH & Co. KG |
| 0x0000B4 | APAG Elektronik AG |
| 0x0000B5 | Nexteer Automotive World Headquarters |
| 0x0000B6 | Hans Widmaier |
| 0x0000B7 | Robert Bosch Battery Systems GmbH |
| 0x0000B8 | KYOCERA Display Corporation |
| 0x0000B9 | MAGNA Powertrain AG & Co KG |
| 0x0000BA | BorgWarner |
| 0x0000BB | BMW - Fahrzeugsimulator |
| 0x0000BC | Benteler Duncan Plant |
| 0x0000BD | U-Shin |
| 0x0000BE | Schaeffler Technologies |
| 0xFFFFFF | unbekannter Hersteller |
FARTTEXTE
Dimensions: 35 rows × 2 columns
| ARTNR | ARTTEXT |
|---|---|
| 0x00 | keine Fehlerart verfügbar |
| 0x04 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x05 | Fehler momentan vorhanden und bereits gespeichert |
| 0x08 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x09 | Fehler momentan vorhanden und bereits gespeichert |
| 0x0C | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x0D | Fehler momentan vorhanden und bereits gespeichert |
| 0x20 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x21 | Fehler momentan vorhanden und bereits gespeichert |
| 0x24 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x25 | Fehler momentan vorhanden und bereits gespeichert |
| 0x28 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x29 | Fehler momentan vorhanden und bereits gespeichert |
| 0x2C | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x2D | Fehler momentan vorhanden und bereits gespeichert |
| 0x40 | unbekannte Fehlerart |
| 0x44 | Fehler gespeichert |
| 0x45 | Fehler gespeichert |
| 0x48 | Fehler gespeichert |
| 0x49 | Fehler gespeichert |
| 0x4C | Fehler gespeichert |
| 0x4D | Fehler gespeichert |
| 0x60 | Fehler gespeichert |
| 0x61 | Fehler gespeichert |
| 0x64 | Fehler gespeichert |
| 0x65 | Fehler gespeichert |
| 0x68 | Fehler gespeichert |
| 0x69 | Fehler gespeichert |
| 0x6C | Fehler gespeichert |
| 0x6D | Fehler gespeichert |
| 0x10 | Testbedingungen erfüllt |
| 0x11 | Testbedingungen noch nicht erfüllt |
| 0x80 | Fehler würde kein Aufleuchten einer Warnlampe verursachen |
| 0x81 | Fehler würde das Aufleuchten einer Warnlampe verursachen |
| 0xFF | unbekannte Fehlerart |
DIGITALARGUMENT
Dimensions: 17 rows × 2 columns
| TEXT | WERT |
|---|---|
| ein | 1 |
| aus | 0 |
| ja | 1 |
| nein | 0 |
| auf | 1 |
| ab | 0 |
| an | 1 |
| yes | 1 |
| no | 0 |
| on | 1 |
| off | 0 |
| up | 1 |
| down | 0 |
| true | 1 |
| false | 0 |
| 1 | 1 |
| 0 | 0 |
PROZESSKLASSEN
Dimensions: 26 rows × 3 columns
| WERT | PROZESSKLASSE | BEZEICHNUNG |
|---|---|---|
| 0x00 | - | ungueltig |
| 0x01 | HWEL | Hardware (Elektronik) |
| 0x02 | HWAP | Hardwareauspraegung |
| 0x03 | HWFR | Hardwarefarbe |
| 0x05 | CAFD | Codierdaten |
| 0x06 | BTLD | Bootloader |
| 0x08 | SWFL | Software ECU Speicherimage |
| 0x09 | SWFF | Flash File Software |
| 0x0A | SWPF | Pruefsoftware |
| 0x0B | ONPS | Onboard Programmiersystem |
| 0x0F | FAFP | FA2FP |
| 0x1A | TLRT | Temporaere Loeschroutine |
| 0x1B | TPRG | Temporaere Programmierroutine |
| 0x07 | FLSL | Flashloader Slave |
| 0x0C | IBAD | Interaktive Betriebsanleitung Daten |
| 0x10 | FCFA | Freischaltcode Fahrzeug-Auftrag |
| 0x1C | BLUP | Bootloader-Update Applikation |
| 0x1D | FLUP | Flashloader-Update Applikation |
| 0xC0 | SWUP | Software-Update Package |
| 0xC1 | SWIP | Index Software-Update Package |
| 0xA0 | ENTD | Entertainment Daten |
| 0xA1 | NAVD | Navigation Daten |
| 0xA2 | FCFN | Freischaltcode Funktion |
| 0x04 | GWTB | Gateway-Tabelle |
| 0x0D | SWFK | BEGU: Detaillierung auf SWE-Ebene |
| 0xFF | - | ungueltig |
SVK_ID
Dimensions: 65 rows × 2 columns
| WERT | BEZEICHNUNG |
|---|---|
| 0x01 | SVK_AKTUELL |
| 0x02 | SVK_SUPPLIER |
| 0x03 | SVK_WERK |
| 0x04 | SVK_BACKUP_01 |
| 0x05 | SVK_BACKUP_02 |
| 0x06 | SVK_BACKUP_03 |
| 0x07 | SVK_BACKUP_04 |
| 0x08 | SVK_BACKUP_05 |
| 0x09 | SVK_BACKUP_06 |
| 0x0A | SVK_BACKUP_07 |
| 0x0B | SVK_BACKUP_08 |
| 0x0C | SVK_BACKUP_09 |
| 0x0D | SVK_BACKUP_10 |
| 0x0E | SVK_BACKUP_11 |
| 0x0F | SVK_BACKUP_12 |
| 0x10 | SVK_BACKUP_13 |
| 0x11 | SVK_BACKUP_14 |
| 0x12 | SVK_BACKUP_15 |
| 0x13 | SVK_BACKUP_16 |
| 0x14 | SVK_BACKUP_17 |
| 0x15 | SVK_BACKUP_18 |
| 0x16 | SVK_BACKUP_19 |
| 0x17 | SVK_BACKUP_20 |
| 0x18 | SVK_BACKUP_21 |
| 0x19 | SVK_BACKUP_22 |
| 0x1A | SVK_BACKUP_23 |
| 0x1B | SVK_BACKUP_24 |
| 0x1C | SVK_BACKUP_25 |
| 0x1D | SVK_BACKUP_26 |
| 0x1E | SVK_BACKUP_27 |
| 0x1F | SVK_BACKUP_28 |
| 0x20 | SVK_BACKUP_29 |
| 0x21 | SVK_BACKUP_30 |
| 0x22 | SVK_BACKUP_31 |
| 0x23 | SVK_BACKUP_32 |
| 0x24 | SVK_BACKUP_33 |
| 0x25 | SVK_BACKUP_34 |
| 0x26 | SVK_BACKUP_35 |
| 0x27 | SVK_BACKUP_36 |
| 0x28 | SVK_BACKUP_37 |
| 0x29 | SVK_BACKUP_38 |
| 0x2A | SVK_BACKUP_39 |
| 0x2B | SVK_BACKUP_40 |
| 0x2C | SVK_BACKUP_41 |
| 0x2D | SVK_BACKUP_42 |
| 0x2E | SVK_BACKUP_43 |
| 0x2F | SVK_BACKUP_44 |
| 0x30 | SVK_BACKUP_45 |
| 0x31 | SVK_BACKUP_46 |
| 0x32 | SVK_BACKUP_47 |
| 0x33 | SVK_BACKUP_48 |
| 0x34 | SVK_BACKUP_49 |
| 0x35 | SVK_BACKUP_50 |
| 0x36 | SVK_BACKUP_51 |
| 0x37 | SVK_BACKUP_52 |
| 0x38 | SVK_BACKUP_53 |
| 0x39 | SVK_BACKUP_54 |
| 0x3A | SVK_BACKUP_55 |
| 0x3B | SVK_BACKUP_56 |
| 0x3C | SVK_BACKUP_57 |
| 0x3D | SVK_BACKUP_58 |
| 0x3E | SVK_BACKUP_59 |
| 0x3F | SVK_BACKUP_60 |
| 0x40 | SVK_BACKUP_61 |
| 0xXY | ERROR_UNKNOWN |
DTCEXTENDEDDATARECORDNUMBER
Dimensions: 5 rows × 3 columns
| WERT | TEXT | ANZ_BYTE |
|---|---|---|
| 0x00 | ISO_RESERVED | 0 |
| 0x01 | CONDITION_BYTE | 1 |
| 0x02 | HFK | 1 |
| 0x03 | HLZ | 1 |
| 0xFF | RECORD_UNKNOWN | 0 |
DTCSNAPSHOTIDENTIFIER
Dimensions: 5 rows × 9 columns
| UWNR | UWTEXT | UW_EINH | L/H | UWTYP | NAME | MUL | DIV | ADD |
|---|---|---|---|---|---|---|---|---|
| 0x1700 | KM_STAND | 0-n | - | 0xFFFFFF | - | 1 | 1 | 0.000000 |
| 0x1701 | ABS_ZEIT | 0-n | - | 0xFFFFFFFF | - | 1 | 1 | 0.000000 |
| 0x1702 | SAE_CODE | 0-n | - | 0xFFFFFF | - | 1 | 1 | 0.000000 |
| 0x1731 | Fehlerklasse_DTC | - | - | u char | - | 1 | 1 | 0.000000 |
| 0xFFFF | IDENTIFIER_UNKNOWN | - | - | 0xFFFFFF | - | 1 | 1 | 0.000000 |
FEHLERKLASSE
Dimensions: 5 rows × 2 columns
| NR | TEXT |
|---|---|
| 0x00 | Keine Fehlerklasse verfuegbar |
| 0x01 | Ueberpruefung bei naechstem Werkstattbesuch |
| 0x02 | Ueberpruefung bei naechstem Halt |
| 0x04 | Ueberpruefung sofort erforderlich ! |
| 0xFF | unbekannte Fehlerklasse |
DIAGMODE
Dimensions: 12 rows × 3 columns
| NR | MODE | MODE_TEXT |
|---|---|---|
| 0x00 | UNGUELTIG | DefaultMode |
| 0x01 | DEFAULT | DefaultMode |
| 0x02 | ECUPM | ECUProgrammingMode |
| 0x03 | ECUEXTDIAG | ECUExtendedDiagnosticSession |
| 0x04 | ECUSSDS | ECUSafetySystemDiagnosticSession |
| 0x40 | ECUEOL | ECUEndOfLineSession |
| 0x41 | ECUCODE | ECUCodingSession |
| 0x42 | ECUSWT | ECUSwtSession |
| 0x43 | ECUHDD | ECUHDDDownloadSession |
| 0x4F | ECUDEVELOP | ECUDevelopmentSession |
| 0x5F | ECUGDM | ECUGarageDiagnoseMode |
| 0xXY | -- | unbekannter Diagnose-Mode |
IARTTEXTE
Dimensions: 18 rows × 2 columns
| ARTNR | ARTTEXT |
|---|---|
| 0x00 | keine Fehlerart verfügbar |
| 0x04 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x05 | Fehler momentan vorhanden und bereits gespeichert |
| 0x08 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x09 | Fehler momentan vorhanden und bereits gespeichert |
| 0x0C | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x0D | Fehler momentan vorhanden und bereits gespeichert |
| 0x44 | Fehler gespeichert |
| 0x45 | Fehler gespeichert |
| 0x48 | Fehler gespeichert |
| 0x49 | Fehler gespeichert |
| 0x4C | Fehler gespeichert |
| 0x4D | Fehler gespeichert |
| 0x10 | Testbedingungen erfüllt |
| 0x11 | Testbedingungen noch nicht erfüllt |
| 0x80 | Fehler würde kein Aufleuchten einer Warnlampe verursachen |
| 0x81 | Fehler würde das Aufleuchten einer Warnlampe verursachen |
| 0xFF | unbekannte Fehlerart |
UDS_TAB_ROE_AKTIV
Dimensions: 3 rows × 2 columns
| NR | TEXT |
|---|---|
| 0x00 | Aktive Fehlermeldung deaktiviert |
| 0x01 | Aktive Fehlermeldung aktiviert |
| 0xFF | Status der aktiven Fehlermeldung nicht feststellbar |
TFBLOCKIDTEXTE
Dimensions: 85 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x01 | NetBlock |
| 0x02 | NetworkMaster |
| 0x03 | ConnectionMaster |
| 0x04 | PowerMaster |
| 0x05 | Vehicle |
| 0x06 | Diagnosis |
| 0x07 | VideoSwitch |
| 0x0F | EnhancedTestability |
| 0x10 | MMI |
| 0x11 | SVS |
| 0x14 | BCStatistic |
| 0x15 | ControlElements |
| 0x20 | AudioMaster |
| 0x22 | AudioAmplifier / AudioAmplifier_HU |
| 0x23 | HeadPhoneAmplifier |
| 0x24 | AuxiliaryInput |
| 0x26 | MicrophoneInput |
| 0x2E | AudioSinkRouter |
| 0x2F | AudioSourceRouter |
| 0x30 | AudioTapePlayer |
| 0x31 | AudioDiskPlayer |
| 0x32 | MultiMediaPlayer |
| 0x40 | AmFmTuner |
| 0x41 | TMCTuner |
| 0x42 | TVTuner |
| 0x43 | DABTuner |
| 0x44 | SatRadio |
| 0x50 | Telephone |
| 0x51 | GeneralPhoneBook / MobileOffice |
| 0x52 | Navigation / NavigationStd |
| 0x54 | Bluetooth |
| 0x6F | Monitor |
| 0x70 | PDC |
| 0x71 | Climate |
| 0x74 | EBA/Services |
| 0x80 | MMI_Terminal |
| 0x81 | Kombi_Terminal |
| 0x82 | HUD_Terminal |
| 0x90 | Telematik |
| 0x91 | InternalAudioSource |
| 0x92 | InternalAudioSink |
| 0xA0 | WLAN |
| 0xA1 | Kleer |
| 0xAB | TollCollect |
| 0xBE | Browser |
| 0xC0 | CANDevices |
| 0xC1 | MPEG-TS_Decoder |
| 0xC9 | Services |
| 0xCA | KombiMiscFKts |
| 0xCB | BordComputer |
| 0xCC | ADASInterface |
| 0xCD | NavigationInfo |
| 0xCE | iSpeech |
| 0xCF | HMIControl |
| 0xD0 | Security |
| 0xD1 | SystemFunction |
| 0xD2 | MultiMediaServer |
| 0xD3 | MassStorageControl |
| 0xD4 | SWUpdate |
| 0xD5 | VirtualControlElements |
| 0xD6 | Vehicle2 |
| 0xD7 | VideoConnectionMaster |
| 0xD8 | VideoSink |
| 0xD9 | EarlyVideoControl |
| 0xDA | MapControl |
| 0xDB | Titelematics |
| 0xDC | DataComIP |
| 0xDD | DUMM |
| 0xDE | TelematikTCU / jetzt TelematicAssist |
| 0xDF | TeleX |
| 0xE0 | KombiInterface |
| 0xE1 | HUDInterface |
| 0xE2 | Camera |
| 0xE3 | MOSTFileSystem |
| 0xE4 | XFCD / Jingle / SoundApplications |
| 0xE5 | CentralControlUnit / CentralControlSystem |
| 0xE6 | TripMemory |
| 0xE7 | RemoteApplication |
| 0xE8 | VideoOutSettings |
| 0xE9 | SoundSignalService |
| 0xEA | PDC |
| 0xEB | DebugApplication |
| 0xED | PIM |
| 0xEE | DataCommunication |
| 0xFF | Nicht definiert |
TWAKEUPSTATUS
Dimensions: 3 rows × 3 columns
| WERT | TEXT | TEXT2 |
|---|---|---|
| 0 | not initialised | off |
| 1 | SG will be waked up | on |
| 2 | SG are waked up | critical |
ARG_0XA001_R
Dimensions: 3 rows × 14 columns
| ARG | STR | STPR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ARG_FREQUENZ | + | - | Hz | - | unsigned int | - | - | 1.0 | 1.0 | 0.0 | 20.0 | 20000.0 | Frequenzeinstellung: 20..20 000 Hz |
| ARG_LEVEL | + | - | - | - | char | - | - | 1.0 | 1.0 | 0.0 | -96.0 | 127.0 | Bei Headunits: Hex-Wert, von 0x00 lückenlos bis 0x7F, Nicht unterstützte Werte (Stereo: 0x3F) dürfen nicht zu Fehlermeldungen führen.Sondern die für das Lautsprechersystem nächstmöglich kleinere verfügbare Lautstärke wird eingestellt. Bei Verstärkern: Integer,-96..0 [dB] |
| ARG_KANAL | + | - | - | - | unsigned long | - | - | 1.0 | 1.0 | 0.0 | - | - | bezeichnet den Kanal, auf dem ausgegeben werden soll. Tabelle TAudioKanal |
ARG_0XA06F_R
Dimensions: 1 rows × 14 columns
| ARG | STR | STPR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ARG_LEISTUNGSZUSTAND | + | - | 0-n | - | unsigned char | - | TAB_AMP_LEISTUNGSZUSTAND | 1.0 | 1.0 | 0.0 | - | - | Leistungszustand des Verstärkers |
ARG_0XD003_D
Dimensions: 1 rows × 12 columns
| ARG | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ARG_KANAL | - | - | unsigned long | - | - | 1.0 | 1.0 | 0.0 | - | - | Kanalnummer |
ARG_0XD05B_D
Dimensions: 2 rows × 12 columns
| ARG | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|
| ARG_LEVEL | - | - | char | - | - | 1.0 | 1.0 | 0.0 | - | - | -96..0 dB |
| ARG_KANAL | - | - | unsigned long | - | - | 1.0 | 1.0 | 0.0 | - | - | Kanalnummer Tabelle TAudioKanal |
BETRIEBSMODE
Dimensions: 2 rows × 3 columns
| WERT | TEXT | BEDEUTUNG |
|---|---|---|
| 0x00 | kein Betriebsmode gesetzt | kein Betriebsmode |
| 0xFF | ungültiger Betriebsmode | ungültig |
DM_TAB_ROE_ACTIVATED_DOP
Dimensions: 2 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | Aktive Fehlermeldung deaktiviert |
| 1 | Aktive Fehlermeldung aktiviert |
ENERGIESPARMODE_DOP
Dimensions: 4 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | Normalmode |
| 1 | Fertigungsmode |
| 2 | Transportmode |
| 3 | Flashmode |
EXTENDED_ENERGY_MODE_DOP
Dimensions: 16 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | Erweiterter Betriebsmodus nicht gesetzt |
| 1 | Erweiterter Betriebsmodus 1 |
| 2 | Erweiterter Betriebsmodus 2 |
| 3 | Erweiterter Betriebsmodus 3 |
| 4 | Erweiterter Betriebsmodus 4 |
| 5 | Erweiterter Betriebsmodus 5 |
| 6 | Erweiterter Betriebsmodus 6 |
| 7 | Erweiterter Betriebsmodus 7 |
| 8 | Erweiterter Betriebsmodus 8 |
| 9 | Erweiterter Betriebsmodus 9 |
| 10 | Erweiterter Betriebsmodus 10 |
| 11 | Erweiterter Betriebsmodus 11 |
| 12 | Erweiterter Betriebsmodus 12 |
| 13 | Erweiterter Betriebsmodus 13 |
| 14 | Erweiterter Betriebsmodus 14 |
| 15 | Erweiterter Betriebsmodus 15 |
FDETAILSTRUKTUR
Dimensions: 6 rows × 2 columns
| NAME | TYP |
|---|---|
| F_UWB_ERW | ja |
| SAE_CODE | nein |
| F_HLZ | nein |
| F_SEVERITY | ja |
| F_UWB_SATZ | 3 |
| F_HLZ_VIEW | - |
FEHLERKLASSE_DOP
Dimensions: 4 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | Keine Fehlerklasse verfuegbar |
| 1 | Ueberpruefung beim naechsten Werkstattbesuch |
| 2 | Ueberpruefung beim naechsten Halt |
| 4 | Ueberpruefung sofort erforderlich |
FORTTEXTE
Dimensions: 21 rows × 3 columns
| ORT | ORTTEXT | EREIGNIS_DTC |
|---|---|---|
| 0x023700 | Energiesparmode aktiv | 0 |
| 0x02FF37 | Dummy-Fehlerspeichereintrag im Komponentenfehlerbereich nur für Testzwecke | 1 |
| 0xB7F481 | Codierung: Steuergerät nicht codiert | 0 |
| 0xB7F482 | Codierung: Fehler bei Codierung aufgetreten | 0 |
| 0xB7F483 | Codierung: Signatur für Daten ungültig | 0 |
| 0xB7F484 | Codierung: Codierung passt nicht zum Fahrzeug | 0 |
| 0xB7F485 | Codierung: Unplausible Daten während Transaktion | 0 |
| 0xB7F490 | Interner Steuergerätefehler Software | 0 |
| 0xB7F491 | Interner Steuergerätefehler Hardware | 0 |
| 0xB7F492 | Ungültige Codierdaten für Equalizing | 0 |
| 0xB7F4A0 | Steuergerät: Übertemperatur erkannt | 1 |
| 0xB7F4E0 | Logikteil: Unterspannung erkannt | 1 |
| 0xB7F4E1 | Lastteil: Unterspannung erkannt | 1 |
| 0xB7F4E2 | Logikteil: Überspannung erkannt | 1 |
| 0xB7F4E3 | Lastteil: Überspannung erkannt | 1 |
| 0xD6C43F | Empfängerknoten: hat Nachricht nicht abgenommen; Puffer voll | 0 |
| 0xD6C440 | Überwachungsschaltung hat Reset ausgelöst | 0 |
| 0xD6C442 | Sender- Empfängerbaustein (FOT): Temperatur übersteigt kritische Schwelle | 0 |
| 0xD6C445 | AMPT: MOST Reset | 0 |
| 0xD6CBFF | Dummy-Fehlerspeichereintrag im Netzwerkfehlerbereich nur für Testzwecke | 1 |
| 0xFFFFFF | unbekannter Fehlerort | 0 |
FUMWELTTEXTE
Dimensions: 13 rows × 9 columns
| UWNR | UWTEXT | UW_EINH | L/H | UWTYP | NAME | MUL | DIV | ADD |
|---|---|---|---|---|---|---|---|---|
| 0x1707 | Diagnose Addresse | Hex | high | unsigned char | - | 1 | 1 | 0 |
| 0x1708 | Klemmenstatus | Hex | high | unsigned char | - | 1 | 1 | 0 |
| 0x1709 | MOST Message Header | text | - | 6 | - | - | - | - |
| 0x170A | Temperatur Sender - Emfpängerbaustein (FOT) | Hex | high | unsigned char | - | 1 | 1 | 0 |
| 0x170B | Node Position Register | Hex | high | unsigned char | - | 1 | 1 | 0 |
| 0x170C | Spannung Batterie | mVolt | high | unsigned int | - | 1 | 1 | 0 |
| 0x170D | MemMirror | Hex | high | unsigned char | - | 1 | 1 | 0 |
| 0x170E | MostMesErrorCodeInfo | Hex | high | unsigned int | - | 1 | 1 | 0 |
| 0x1721 | Reset Reason | Hex | high | unsigned char | - | 1 | 1 | 0 |
| 0x172D | MOSTMesOpType | Hex | high | unsigned int | - | 1 | 1 | 0 |
| 0x172E | HighSyncConnectionTable | Hex | high | unsigned int | - | 1 | 1 | 0 |
| 0x172F | NotificationTable | Hex | high | unsigned int | - | 1 | 1 | 0 |
| 0xXYXY | unbekannte Umweltbedingung | - | - | - | - | - | - | - |
IDETAILSTRUKTUR
Dimensions: 4 rows × 2 columns
| NAME | TYP |
|---|---|
| F_UWB_ERW | ja |
| SAE_CODE | nein |
| F_HLZ | nein |
| F_SEVERITY | nein |
IORTTEXTE
Dimensions: 11 rows × 3 columns
| ORT | ORTTEXT | EREIGNIS_DTC |
|---|---|---|
| 0x930001 | Versorgungsspannung: Mindestwert unterschritten | 1 |
| 0x930002 | Sender- Empfängerbaustein (FOT): Temperatur übersteigt Schwelle 1 | 0 |
| 0x930003 | Sender- Empfängerbaustein (FOT): Temperatur übersteigt Schwelle 2 | 0 |
| 0x930004 | Diagnose-Master-Client: Datenzwischenablage im Active Response Handler übergelaufen | 1 |
| 0x930005 | Diagnose-Master-Client: Telegramm Systemzeit nicht firstgerecht erhalten | 1 |
| 0x930006 | MOST: Licht geht unerwartet aus | 0 |
| 0x930007 | MOST: Synchronisation (PLL) arbeitet nicht korrekt | 0 |
| 0x930008 | Systemzustand Ok nicht fristgerecht erkannt | 0 |
| 0x930011 | MOST: Ringbruch | 1 |
| 0xB7F495 | Entwickler-EQ: ungültige Checksumm | 0 |
| 0xFFFFFF | unbekannter Fehlerort | 0 |
IUMWELTTEXTE
Dimensions: 13 rows × 9 columns
| UWNR | UWTEXT | UW_EINH | L/H | UWTYP | NAME | MUL | DIV | ADD |
|---|---|---|---|---|---|---|---|---|
| 0x1707 | Diagnose Addresse | Hex | high | unsigned char | - | 1 | 1 | 0 |
| 0x1708 | Klemmenstatus | Hex | high | unsigned char | - | 1 | 1 | 0 |
| 0x1709 | MOST-Messageheader | text | high | 6 | - | 1 | 1 | 0 |
| 0x170A | Temperatur Sender - Emfpängerbaustein (FOT) | Hex | high | unsigned char | - | 1 | 1 | 0 |
| 0x170B | Node Position Register | Hex | high | unsigned char | - | 1 | 1 | 0 |
| 0x170C | Spannung Batterie | mVolt | high | unsigned int | - | 1 | 1 | 0 |
| 0x170D | MemMirror | Hex | high | unsigned char | - | 1 | 1 | 0 |
| 0x171E | MostMesErrorCodeInfo | Hex | high | unsigned int | - | 1 | 1 | 0 |
| 0x1721 | Reset Reason | Hex | high | unsigned char | - | 1 | 1 | 0 |
| 0x172D | MOSTMesOpType | Hex | high | unsigned int | - | 1 | 1 | 0 |
| 0x172E | HighSyncConnectionTable | Hex | high | unsigned int | - | 1 | 1 | 0 |
| 0x172F | NotificationTable | Hex | high | unsigned int | - | 1 | 1 | 0 |
| 0xXYXY | unbekannte Umweltbedingung | - | - | - | - | - | - | - |
JOBRESULTEXTENDED
Dimensions: 1 rows × 2 columns
| SB | STATUS_TEXT |
|---|---|
| 0xXY | ERROR_UNKNOWN |
LEISTUNGSZUSTAND
Dimensions: 4 rows × 2 columns
| WERT | TEXT |
|---|---|
| 1 | MSA-Start |
| 2 | PowerSave |
| 3 | Standard |
| 4 | High Performance |
PROG_DEP_DOP
Dimensions: 6 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | reserved |
| 1 | correctResult |
| 2 | incorrectResult |
| 3 | incorrectResult error SWE - HWE |
| 4 | incorrectResult error SWE - SWE |
| 255 | reserved |
RDBI_ADS_DOP
Dimensions: 8 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | ISOSAEReserved_00 |
| 1 | defaultSession |
| 2 | programmingSession |
| 3 | extendedDiagnosticSession |
| 4 | safetySystemDiagnosticSession |
| 64 | vehicleManufacturerSpecific_40 |
| 65 | codingSession |
| 66 | SWTSession |
RDBI_PC_PCS_DOP
Dimensions: 3 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | ECUMehrmalsProgrammierbar |
| 1 | ECUMindestensEinmalVollstaendigProgrammierbar |
| 2 | ECUNichtMehrProgrammierbar |
RDTCI_LEV_DOP
Dimensions: 9 rows × 2 columns
| WERT | TEXT |
|---|---|
| 2 | reportDTCByStatusMask |
| 4 | reportDTCsnapshotRecordByDTCnumber |
| 6 | reportDTCextendedDataRecordByDTCnumber |
| 7 | reportNumberOfDTCbySeverityMaskRecord |
| 8 | reportDTCbySeverityMaskRecord |
| 9 | reportSeverityInformationOfDTC |
| 10 | reportSupportedDTC |
| 18 | reportNumberOfEmissionsRelatedOBDDTCByStatusMask |
| 19 | reportEmissionsRelatedOBDDTCByStatusMask |
RES_0XA06F_R
Dimensions: 1 rows × 13 columns
| RESULTNAME | STR | STPR | RRR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| STAT_LEISTUNGSZUSTAND | - | - | + | 0-n | - | unsigned char | - | TAB_AMP_LEISTUNGSZUSTAND | 1.0 | 1.0 | 0.0 | Leistungszustand des Verstärkers |
RES_0XD003_D
Dimensions: 1 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_KANAL | 0-n | - | unsigned long | - | TAudioKanal | 1.0 | 1.0 | 0.0 | Kanalnummer |
RES_0XD026_D
Dimensions: 6 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_TEMP_FOT_WERT | °C | - | char | - | - | 1.0 | 1.0 | 0.0 | liefert die Temperatur des Fibre Optical Transceivers (FOT). Bereich: -127,&,127 |
| STAT_TEMP_ENDSTU_WERT | °C | - | int | - | - | 1.0 | 1.0 | 0.0 | liefert die Temperatur der Endstufe. Bereich: -32767,&, 32767 |
| STAT_TEMP_GYRO_WERT | °C | - | char | - | - | 1.0 | 1.0 | 0.0 | liefert die Temperatur des Gyro. Bereich: -127,&,127 |
| STAT_TEMP_MOD_WERT | °C | - | char | - | - | 1.0 | 1.0 | 0.0 | liefert die Temperatur des Moduls (normalerweise prozessornah). Bereich: -127,&,127 |
| STAT_TEMP_HDD_WERT | °C | - | char | - | - | 1.0 | 1.0 | 0.0 | liefert die Temperatur des HDD-Laufwerks. Bereich: -127,&,127 |
| STAT_TEMP_DVD_WERT | °C | - | char | - | - | 1.0 | 1.0 | 0.0 | liefert die Temperatur des DVD-Laufwerks. Bereich: -127,&,127 |
RES_0XD05B_D
Dimensions: 2 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_LEVEL_WERT | - | - | char | - | - | 1.0 | 1.0 | 0.0 | -96..0 dB |
| STAT_KANAL | 0-n | - | unsigned long | - | TAudioKanal | 1.0 | 1.0 | 0.0 | Kanalnummer |
ROE_EWT_DOP
Dimensions: 1 rows × 2 columns
| WERT | TEXT |
|---|---|
| 2 | infiniteTimeToResponse |
SG_FUNKTIONEN
Dimensions: 6 rows × 16 columns
| ARG | ID | RESULTNAME | INFO | EINHEIT | LABEL | L/H | DATENTYP | NAME | MUL | DIV | ADD | SG_ADR | SERVICE | ARG_TABELLE | RES_TABELLE |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SINUSGENERATOR | 0xA001 | - | Gibt einen Sinuston auf einen oder mehrere Kanäle aus. | - | - | - | - | - | - | - | - | - | 31 | ARG_0xA001_R | - |
| LEISTUNGSZUSTAENDE | 0xA06F | - | Steuert die Leistungszustände des Verstärkers | - | - | - | - | - | - | - | - | - | 31 | ARG_0xA06F_R | RES_0xA06F_R |
| AUDIOKANAELE | 0xD003 | - | Verstellt und liest den aktuell eingestellten Lautsprecherkanal. | - | - | - | - | - | - | - | - | - | 2E;22 | ARG_0xD003_D | RES_0xD003_D |
| STATUS_ANALOG_TEMPERATUR | 0xD026 | - | Abfrage der Temperaturen des Steuergerätes. | - | - | - | - | - | - | - | - | - | 22 | - | RES_0xD026_D |
| LAUTSPRECHER_AUSGANG | 0xD05B | - | Verstellt und liest gleichzeitig Kanal und Lautstärke | - | - | - | - | - | - | - | - | - | 22;2E | ARG_0xD05B_D | RES_0xD05B_D |
| LEISTUNGSZUSTAENDE_MOST | 0x4FFD | STAT_LEISTUNGSZUSTAND | Leistungszustände MOST | 0-n | - | high | unsigned char | LEISTUNGSZUSTAND | - | - | - | - | 22 | - | - |
SVK_VERSION_DOP
Dimensions: 2 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | reserved |
| 1 | SVKVersion_01 |
TAB_ABILITY_TO_WAKE_DOP
Dimensions: 3 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | off |
| 1 | on |
| 2 | critical |
TAB_AMP_LEISTUNGSZUSTAND
Dimensions: 4 rows × 2 columns
| WERT | TEXT |
|---|---|
| 1 | Default |
| 2 | MSA_START |
| 3 | Powersave |
| 4 | High_Performance |
TAB_SENSOR_TEMP_DOP
Dimensions: 2 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | Sensor unbekannt |
| 1 | FOT |
TAB_WAKE_UP_STATUS_DOP
Dimensions: 3 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | nicht initialisiert |
| 1 | Steuergeraet hat geweckt |
| 2 | Steuergeraet wurde geweckt |
TAUDIOKANAL
Dimensions: 26 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00000000 | Alle Kanäle |
| 0x00000001 | Links vorne (Standardkanal, speziell Mitteltöner wenn getrennte Hoch/Mitteltöner) |
| 0x00000002 | Rechts vorne (Standardkanal, speziell Mitteltöner wenn getrennte Hoch/Mitteltöner) |
| 0x00000004 | Center vorne (Erweiterter Kanal, speziell Mitteltöner wenn getrennte Hoch/Mitteltöner) |
| 0x00000008 | Seite links (Erweiterter Kanal, speziell Mitteltöner wenn getrennte Hoch/Mitteltöner) |
| 0x00000010 | Seite rechts (Erweiterter Kanal, speziell Mitteltöner wenn getrennte Hoch/Mitteltöner) |
| 0x00000020 | Links hinten (Standardkanal, speziell Mitteltöner wenn getrennte Hoch/Mitteltöner) |
| 0x00000040 | Rechts hinten (Standardkanal, speziell Mitteltöner wenn getrennte Hoch/Mitteltöner) |
| 0x00000080 | Links vorne Bass (Erweiterter Kanal) |
| 0x00000100 | Rechts vorne Bass (Erweiterter Kanal) |
| 0x00000200 | Links hinten Bass (Erweiterter Kanal) |
| 0x00000400 | Rechts hinten Bass (Erweiterter Kanal) |
| 0x00000800 | Center hinten (Erweiterter Kanal, speziell Mitteltöner wenn getrennte Hoch/Mitteltöner) |
| 0x00001000 | Linker Kopfhörer links |
| 0x00002000 | Linker Kopfhörer rechts |
| 0x00004000 | Rechter Kopfhörer links |
| 0x00008000 | Rechter Kopfhörer rechts |
| 0x00010000 | Links vorne (Erweiterter Kanal, speziell Hochtöner wenn getrennte Hoch/Mitteltöner) |
| 0x00020000 | Rechts vorne (Erweiterter Kanal, speziell Hochtöner wenn getrennte Hoch/Mitteltöner) |
| 0x00040000 | Center vorne (Erweiterter Kanal, speziell Hochtöner wenn getrennte Hoch/Mitteltöner) |
| 0x00080000 | Seite links (Erweiterter Kanal, speziell Hochtöner wenn getrennte Hoch/Mitteltöner) |
| 0x00100000 | Seite rechts (Erweiterter Kanal, speziell Hochtöner wenn getrennte Hoch/Mitteltöner) |
| 0x00200000 | Links hinten (Erweiterter Kanal, speziell Hochtöner wenn getrennte Hoch/Mitteltöner) |
| 0x00400000 | Rechts hinten (Erweiterter Kanal, speziell Hochtöner wenn getrennte Hoch/Mitteltöner) |
| 0x00800000 | Center hinten (Erweiterter Kanal, speziell Hochtöner wenn getrennte Hoch/Mitteltöner) |
| 0xFFFFFFFF | Nicht definiert |
TKEYNR
Dimensions: 16 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x01 | Schlüssel 1 |
| 0x02 | Schlüssel 2 |
| 0x03 | Schlüssel 3 |
| 0x04 | Schlüssel 4 |
| 0x05 | Schlüssel 5 |
| 0x06 | Schlüssel 6 |
| 0x07 | Schlüssel 7 |
| 0x08 | Schlüssel 8 |
| 0x09 | Schlüssel 9 |
| 0x0A | Schlüssel 10 |
| 0x0B | Schlüssel 11 |
| 0x0C | Schlüssel 12 |
| 0x0D | Schlüssel 13 |
| 0x0E | Schlüssel 14 |
| 0x0F | Schlüssel 15 |
| 0xFF | Alle Schlüssel |
TRADONLEAD
Dimensions: 3 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00 | aus |
| 0x01 | ein |
| 0xFF | Nicht definiert |