cecall.prg
INFO
| Field | Value |
|---|---|
| ECU | COMBOX Emergency Call |
| ORIGIN | BMW EI43 Thomas_Sykora |
| REVISION | 3.000 |
| AUTHOR | Harman/Becker EDB2 RGoeckelmann, Harman/Becker EDB1 FAnschuetz, |
| COMMENT | COMBOX_ECALL [13] |
| PACKAGE | 1.17 |
| SPRACHE | deutsch |
Jobs
Index
- INFO - Information SGBD
- INITIALISIERUNG - Initialisierung und Kommunikationsparameter
- IDENT - Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
- FS_LESEN - Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
- FS_LESEN_DETAIL - Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
- FS_LOESCHEN - Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
- PRUEFSTEMPEL_LESEN - Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
- PRUEFSTEMPEL_SCHREIBEN - Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
- SVK_LESEN - Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
- STATUS_LESEN - Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
- STEUERN - Vorgeben eines Status UDS : $2E WriteDataByIdentifier
- SERIENNUMMER_LESEN - Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
- STEUERN_IO - Vorgeben eines Status UDS : $2F InputOutputControlByIdentifier
- STEUERN_ROUTINE - Vorgeben eines Status UDS : $31 RoutineControl
- FS_SPERREN - Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
- IS_LESEN - Sekundaerer Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $22 ReadDataByIdentifierRequestServiceID UDS : $2000 DataIdentifier sekundaerer Fehlerspeicher Modus: Default
- IS_LESEN_DETAIL - sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $22 ReadDataByIdentifier UDS : $20 dataIdentifier UDS : $00 alle Info-Meldungen anschließend UDS : $20 dataIdentifier UDS : $nn Details zur Info-Meldung an der Position n Modus: Default
- IS_LOESCHEN - Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default
- STATUS_BLOCK_LESEN - Lesen eines dynamisch definierten Datenblockes UDS : $2C DynamicallyDefineDataIdentifier $03 ClearDynamicallyDefinedDataIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier UDS : $2C DynamicallyDefineDataIdentifier $01 DefineByIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier UDS : $22 ReadDataByIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier $2C$02 DefineByMemoryAddress wird nicht unterstützt 'Composite data blocks' werden nur komplett unterstützt
- HERSTELLINFO_LESEN - Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
- DIAGNOSE_AUFRECHT - Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
- DIAGNOSE_MODE - SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
- SLEEP_MODE - SG in Sleep-Mode versetzen UDS : $11 ECUReset UDS : $04 EnableRapidPowerShutDown Modus: Default
- ENERGIESPARMODE - Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
- STATUS_ENERGIESPARMODE - Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
- STATUS_BETRIEBSMODE - Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default
- STEUERN_BETRIEBSMODE - Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default
- STEUERGERAETE_RESET - Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
- STEUERN_ROE_STOP - Temporaeres Deaktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $00 Stop $02 (EventWindowTime)
- STATUS_ROE_REPORT - Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $04 report activated events
- STEUERN_ROE_START - Temporaeres Aktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $05 Start $02 (EventWindowTime)
- STEUERN_ROE_PERSISTENT_STOP - Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime)
- STEUERN_ROE_PERSISTENT_START - Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime)
- CPS_LESEN - Codierpruefstempel lesen UDS : $22 ReadDataByIdentifier UDS : $37FE DataIdentifier Codierpruefstempel Modus: Default
- DIAG_SESSION_LESEN - Aktive Diagnose-Session auslesen UDS : $22 ReadDataByIdentifier UDS : $F186 ActiveDiagnosticSession Modus: Default
- FLASH_TP_LESEN - Flash Timing Parameter auslesen UDS : $22 ReadDataByIdentifier UDS : $2504 FlashTimingParameter Modus: Default
- PROG_ZAEHLER_LESEN - Programmierzaehler lesen UDS : $22 ReadDataByIdentifier UDS : $2502 ProgrammingCounter Modus: Default
- PROG_MAX_LESEN - Anzahl der maximal möglichen Programmiervorgänge auslesen UDS : $22 ReadDataByIdentifier UDS : $2503 ProgrammingCounter Modus: Default
- SCHREIBEN_CONFIGURATION - UDS: $31 RoutineControl $01 StartRoutine $F001 SCHREIBEN_CONFIGURATION
- LESEN_CONFIGURATION - UDS: $31 RoutineControl $01 StartRoutine $F002 LESEN_CONFIGURATION
- LESEN_DPAS - UDS: $31 RoutineControl $01 StartRoutine $F004 LESEN_DPAS
- STEUERN_LED - Einschalten der eCall Button LED für die Werksdiagnose
- STATUS_POWERMANAGEMENT_NEC - Auslesen der gespeicherten internen Powermanagement Transitionen
- STATUS_POWERMANAGEMENT_NAD - Auslesen der gespeicherten internen Powermanagement Transitionen
- STATUS_ECALL_LOGGING - Auslesen der gespeicherten internen EU ecall Loggings
INFO
Information SGBD
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| ECU | string | Steuergerät im Klartext |
| ORIGIN | string | Steuergeräte-Verantwortlicher |
| REVISION | string | Versions-Nummer |
| AUTHOR | string | Namen aller Autoren |
| COMMENT | string | wichtige Hinweise |
| PACKAGE | string | Include-Paket-Nummer |
| SPRACHE | string | deutsch, english |
INITIALISIERUNG
Initialisierung und Kommunikationsparameter
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| DONE | int | 1, wenn Okay |
IDENT
Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| ID_SG_ADR | long | Steuergeraeteadresse |
| ID_SGBD_INDEX | long | Index zur Erkennung der SG-Variante |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FS_LESEN
Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FS_LESEN_DETAIL
Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| F_CODE | long | gewaehlter Fehlercode |
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_HFK | int | Haufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf |
| F_HLZ | int | Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Haufigkeitszaehler |
| F_UEBERLAUF | int | 0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers |
| F_FEHLERKLASSE_NR | int | 0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich ! |
| F_FEHLERKLASSE_TEXT | string | Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT |
| F_UW_ANZ | int | Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung |
| F_UW_KM | long | Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht |
| F_UW_ZEIT | long | Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_SAE_CODE | unsigned int | Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD |
| F_SAE_CODE_STRING | string | 5 stelliger Text in der Form 'Sxxxx' |
| F_SAE_CODE_TEXT | string | Text zu F_SAE_CODE |
| _RESPONSE_SNAPSHOT | binary | Hex-Antwort von SG |
| _RESPONSE_EXTENDED_DATA | binary | Hex-Antwort von SG |
| _RESPONSE_SEVERITY | binary | Hex-Antwort von SG |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
FS_LOESCHEN
Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| F_CODE | long | 0x??????: Angabe eines einzelnen Fehlers Default: 0xFFFFFF: alle Fehler |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PRUEFSTEMPEL_LESEN
Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| BYTE1 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE2 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE3 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PRUEFSTEMPEL_SCHREIBEN
Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| BYTE1 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE2 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE3 | int | Bereich: 0-255 bzw. 0x00-0xFF |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
SVK_LESEN
Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| SVK | string | table SVK_ID BEZEICHNUNG WERT default SVK_AKTUELL |
Results
| Name | Type | Comment |
|---|---|---|
| PROG_TEST | int | Programmierabhaengigkeiten (ProgrammingDependenciesChecked) 1: IO : Signaturpruefung und ProgrammingDependenciesCheck erfolgreich 2: NIO: mindestens eine SWE fehlerhaft oder ProgrammingDependenciesCheck nicht durchgefuehrt 3: NIO: mindestens eine SWE passt nicht mit einer HWE zusammen 4: NIO: mindestens eine SWE passt nicht mit einer anderen SWE zusammen sonst: reserviert |
| ANZAHL_EINHEITEN | int | Anzahl der xWEn |
| PROG_DATUM | string | Programmierdatum (DD.MM.YY) |
| PROG_KM | long | KM-Stand bei Programmierung (10 KM bis 655350 KM) Inkrement sind 10 KM -1: KM-Stand wird nicht unterstuetzt |
| PROZESSKLASSE_WERT | int | table Prozessklassen WERT dezimale Angabe der Prozessklasse |
| PROZESSKLASSE_TEXT | string | table Prozessklassen BEZEICHNUNG Text-Angabe der Prozessklasse |
| PROZESSKLASSE_KURZTEXT | string | table Prozessklassen PROZESSKLASSE Text-Angabe des Prozessklassenkurztextes |
| SGBM_IDENTIFIER | string | Angabe SGBM-ID der Prozessklasse |
| VERSION | string | Angabe der Version der Prozessklasse |
| SGBM_ID | string | Angabe von Prozessklasse, SGBM-Identifier, Version |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_LESEN
Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Es muss mindestens ein Argument übergeben werden Es wird das zugehörige result erzeugt table SG_Funktionen ARG ID RESULTNAME RES_TABELLE ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN
Vorgeben eines Status UDS : $2E WriteDataByIdentifier
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Siehe table SG_Funktionen ARG ID LABEL ARG_TABELLE |
| WERT | string | Es muss mindestens ein Argument übergeben werden Argumente siehe table SG_Funktionen ARG ID ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
SERIENNUMMER_LESEN
Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| SERIENNUMMER | string | Seriennummer des Steuergeraets |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_IO
Vorgeben eines Status UDS : $2F InputOutputControlByIdentifier
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Siehe table SG_Funktionen ARG ID RES_TABELLE ARG_TABELLE |
| STEUERPARAMETER | string | 'RCTECU' = returnControlToECU 'RTD' = resetToDefault 'FCS' = freezeCurrentState 'STA' = shortTermAdjustment optionales Argument Wenn nicht angegeben, dann kein InputOutputControlParameter im Request |
| WERT | string | Argumente siehe table SG_Funktionen ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROUTINE
Vorgeben eines Status UDS : $31 RoutineControl
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Siehe table SG_Funktionen ARG ID RES_TABELLE ARG_TABELLE |
| STEUERPARAMETER | string | 'STR' = startRoutine 'STPR' = stopRoutine 'RRR' = requestRoutineResults |
| WERT | string | Argumente siehe table SG_Funktionen ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FS_SPERREN
Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| SPERREN | string | "ja" -> Fehlerspeicher sperren "nein" -> Fehlerspeicher freigeben table DigitalArgument TEXT Default: "ja" |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
IS_LESEN
Sekundaerer Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $22 ReadDataByIdentifierRequestServiceID UDS : $2000 DataIdentifier sekundaerer Fehlerspeicher Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
IS_LESEN_DETAIL
sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $22 ReadDataByIdentifier UDS : $20 dataIdentifier UDS : $00 alle Info-Meldungen anschließend UDS : $20 dataIdentifier UDS : $nn Details zur Info-Meldung an der Position n Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| F_CODE | long | gewaehlter Infocode Wenn dieser Parameter angegeben wird, wird die Position automatisch ermittelt. Es darf dann nicht argument F_POS angegeben werden |
| F_POS | int | gewaehlter Eintrag Wenn dieser Parameter angegeben wird, wird die Position benutzt. Wertebereich 1 - 255 Es darf dann nicht argument F_CODE angegeben werden |
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_HFK | int | Haufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf |
| F_HLZ | int | Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Haufigkeitszaehler |
| F_UEBERLAUF | int | 0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers |
| F_FEHLERKLASSE_NR | int | 0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich ! |
| F_FEHLERKLASSE_TEXT | string | Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT |
| F_UW_ANZ | int | Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung |
| F_UW_KM | long | Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht |
| F_UW_ZEIT | long | Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_SAE_CODE | unsigned int | Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD |
| F_SAE_CODE_STRING | string | 5 stelliger Text in der Form 'Sxxxx' |
| F_SAE_CODE_TEXT | string | Text zu F_SAE_CODE |
| _RESPONSE_2000 | binary | Hex-Antwort von SG |
| _RESPONSE_200X | binary | Hex-Antwort von SG |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
IS_LOESCHEN
Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_BLOCK_LESEN
Lesen eines dynamisch definierten Datenblockes UDS : $2C DynamicallyDefineDataIdentifier $03 ClearDynamicallyDefinedDataIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier UDS : $2C DynamicallyDefineDataIdentifier $01 DefineByIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier UDS : $22 ReadDataByIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier $2C$02 DefineByMemoryAddress wird nicht unterstützt 'Composite data blocks' werden nur komplett unterstützt
Arguments
| Name | Type | Comment |
|---|---|---|
| BLOCK_NR | long | Nummer des Blockes 0..255 |
| NEU_DEFINIEREN | string | Wenn 'JA' oder 'YES' wird der Block im SG gelöscht und neu ins SG geschrieben Wenn 'NEIN' oder 'NO' wird der Block im SG nicht gelöscht und nicht geschrieben Anschließend wird der Block gelesen |
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Es muss mindestens ein Argument übergeben werden Es wird das zugehörige Result table SG_Funktionen ARG ID RESULTNAME erzeugt |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST_1 | binary | Hex-Antwort von SG |
| _RESPONSE_1 | binary | Hex-Antwort von SG |
| _REQUEST_2 | binary | Hex-Antwort von SG |
| _RESPONSE_2 | binary | Hex-Antwort von SG |
| _REQUEST_3 | binary | Hex-Antwort von SG |
| _RESPONSE_3 | binary | Hex-Antwort von SG |
HERSTELLINFO_LESEN
Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| ID_LIEF_NR | long | Lieferantennummer 0xFFFFFF, falls nicht vorhanden |
| ID_LIEF_TEXT | string | Text zu ID_LIEF_NR table Lieferanten LIEF_TEXT unbekannter Hersteller, falls nicht vorhanden |
| ID_DATUM | string | Herstelldatum (DD.MM.YY) |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
| _REQUEST_2 | binary | Hex-Auftrag an SG |
| _RESPONSE_2 | binary | Hex-Antwort von SG |
DIAGNOSE_AUFRECHT
Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| SG_ANTWORT | string | "ja" -> SG soll antworten "nein" -> SG soll nicht antworten table DigitalArgument TEXT Default: SG soll antworten |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
DIAGNOSE_MODE
SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
Arguments
| Name | Type | Comment |
|---|---|---|
| MODE | string | gewuenschter Diagnose-Modus table DiagMode MODE MODE_TEXT Defaultwert: DEFAULT (DefaultMode) |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
SLEEP_MODE
SG in Sleep-Mode versetzen UDS : $11 ECUReset UDS : $04 EnableRapidPowerShutDown Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
ENERGIESPARMODE
Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
Arguments
| Name | Type | Comment |
|---|---|---|
| MODE | int | 0x00: Normalmode 0x01: Fertigungsmode 0x02: Transportmode 0x03: Flashmode |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_ENERGIESPARMODE
Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_ENERGIESPARMODE_WERT | int | Ausgabe des Energiesparmodes 0: Kein Energiesparmode gesetzt 1: Produktionsmode gesetzt 2: Transportmode gesetzt 3: Flashmode gesetzt -1: Mode ungueltig |
| STAT_ENERGIESPARMODE_TEXT | string | Text zu STAT_ENERGIESPARMODE_WERT |
| STAT_PRODUKTIONSMODE_EIN | int | 0: Produktionsmode nicht aktiv 1: Produktionsmode aktiv |
| STAT_TRANSPORTMODE_EIN | int | 0: Transportmode nicht aktiv 1: Transportmode aktiv |
| STAT_FLASHMODE_EIN | int | 0: Flashmode nicht aktiv 1: Flashmode aktiv |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_BETRIEBSMODE
Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_BETRIEBSMODE_WERT | int | Aktueller Betriebsmode table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle) |
| STAT_BETRIEBSMODE_TEXT | string | Textausgabe STAT_BETRIEBSMODE_WERT table Betriebsmode TEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_BETRIEBSMODE
Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| BETRIEBSMODE | int | Betriebsmode setzen table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle) |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERGERAETE_RESET
Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_STOP
Temporaeres Deaktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $00 Stop $02 (EventWindowTime)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_ROE_REPORT
Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $04 report activated events
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_ROE_AKTIV | char | 0x00 = Aktive Fehlermeldung deaktiviert 0x01 = Aktive Fehlermeldung aktiviert 0xFF = Status der aktiven Fehlermeldung nicht feststellbar |
| STAT_ROE_AKTIV_TEXT | string | Interpretation von STAT_ROE_AKTIV table UDS_TAB_ROE_AKTIV TEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_START
Temporaeres Aktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $05 Start $02 (EventWindowTime)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_PERSISTENT_STOP
Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_PERSISTENT_START
Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
CPS_LESEN
Codierpruefstempel lesen UDS : $22 ReadDataByIdentifier UDS : $37FE DataIdentifier Codierpruefstempel Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| CPS | string | Codierpruefstempel 7-stellig |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
DIAG_SESSION_LESEN
Aktive Diagnose-Session auslesen UDS : $22 ReadDataByIdentifier UDS : $F186 ActiveDiagnosticSession Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| DIAG_SESSION_WERT | int | Diagnose-Session (1 Byte) |
| DIAG_SESSION_TEXT | string | Diagnose-Session als Text |
| DIAG_DETAIL_WERT | int | Details zur Diagnose-Session (1 Byte) |
| DIAG_DETAIL_TEXT | string | Details zur Diagnose-Session als Text |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FLASH_TP_LESEN
Flash Timing Parameter auslesen UDS : $22 ReadDataByIdentifier UDS : $2504 FlashTimingParameter Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| FLASH_LOESCHEN | int | EraseMemoryTime (2 Byte) |
| FLASH_TEST | int | CheckMemoryTime (2 Byte) |
| FLASH_BOOT | int | BootloaderInstallationTime (2 Byte) |
| FLASH_AUTHENT | int | AuthenticationTime (2 Byte) |
| FLASH_RESET | int | ResetTime (2 Byte) |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PROG_ZAEHLER_LESEN
Programmierzaehler lesen UDS : $22 ReadDataByIdentifier UDS : $2502 ProgrammingCounter Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| PROG_ZAEHLER_STATUS_WERT | int | Status, wie oft das SG programmierbar ist |
| PROG_ZAEHLER_STATUS_TEXT | string | Status, wie oft das SG programmierbar ist |
| PROG_ZAEHLER | int | Programmierzaehler |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PROG_MAX_LESEN
Anzahl der maximal möglichen Programmiervorgänge auslesen UDS : $22 ReadDataByIdentifier UDS : $2503 ProgrammingCounter Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| PROG_MAX | long | maximal mögliche Programmiervorgänge Sonderfall 0xFFFF: Anzahl der Programmiervorgänge unbegrenzt |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
SCHREIBEN_CONFIGURATION
UDS: $31 RoutineControl $01 StartRoutine $F001 SCHREIBEN_CONFIGURATION
Arguments
| Name | Type | Comment |
|---|---|---|
| ARG_PFAD | string | Pfad |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, if without errors table JobResult STATUS_TEXT |
LESEN_CONFIGURATION
UDS: $31 RoutineControl $01 StartRoutine $F002 LESEN_CONFIGURATION
Arguments
| Name | Type | Comment |
|---|---|---|
| ARG_PFAD | string | Pfad (optional) |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, if without errors table JobResult STATUS_TEXT |
| OTA_DATA | binary | Hex-respone from ECU |
LESEN_DPAS
UDS: $31 RoutineControl $01 StartRoutine $F004 LESEN_DPAS
Arguments
| Name | Type | Comment |
|---|---|---|
| ARG_PFAD | string | Pfad (optional) |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, if without errors table JobResult STATUS_TEXT |
| DPAS_DATA | binary | Hex-respone from ECU |
STEUERN_LED
Einschalten der eCall Button LED für die Werksdiagnose
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | "OKAY", wenn fehlerfrei |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_POWERMANAGEMENT_NEC
Auslesen der gespeicherten internen Powermanagement Transitionen
Arguments
| Name | Type | Comment |
|---|---|---|
| ARG_DATASET | unsigned char | Dataset number requested Index starts with 0x01 |
Results
| Name | Type | Comment |
|---|---|---|
| STAT_STATUS_TEXT | string | values from table TPowerStateNEC |
| STAT_EVENT_TEXT | string | values from table TPowerEventNEC |
| STAT_TIMESTAMP | string | Timestamp as hex string |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_POWERMANAGEMENT_NAD
Auslesen der gespeicherten internen Powermanagement Transitionen
Arguments
| Name | Type | Comment |
|---|---|---|
| ARG_DATASET | unsigned char | Dataset number requested |
Results
| Name | Type | Comment |
|---|---|---|
| STAT_STATUS_TEXT | string | values from table TPowerStateNAD |
| STAT_EVENT_TEXT | string | values from table TPowerEventNAD |
| STAT_TIMESTAMP | string | Timestamp as hex string |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_ECALL_LOGGING
Auslesen der gespeicherten internen EU ecall Loggings
Arguments
| Name | Type | Comment |
|---|---|---|
| ARG_DATASET | unsigned char | Dataset number requested Index starts with 0x01 |
Results
| Name | Type | Comment |
|---|---|---|
| STAT_STATUS_TEXT | string | values from table TPowerStateNEC |
| STAT_EVENT_TEXT | string | values from table TPowerEventNEC |
| STAT_TIMESTAMP | string | Timestamp as hex string |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
Tables
Index
- JOBRESULT (66 × 2)
- LIEFERANTEN (121 × 2)
- FARTTEXTE (19 × 2)
- DIGITALARGUMENT (17 × 2)
- PROZESSKLASSEN (24 × 3)
- SVK_ID (65 × 2)
- DTCEXTENDEDDATARECORDNUMBER (5 × 3)
- DTCSNAPSHOTIDENTIFIER (5 × 9)
- FEHLERKLASSE (5 × 2)
- DIAGMODE (11 × 3)
- IARTTEXTE (18 × 2)
- UDS_TAB_ROE_AKTIV (3 × 2)
- JOBRESULTEXTENDED (1 × 2)
- BETRIEBSMODE (2 × 3)
- FORTTEXTE (52 × 3)
- FDETAILSTRUKTUR (6 × 2)
- IORTTEXTE (6 × 3)
- IDETAILSTRUKTUR (4 × 2)
- SG_FUNKTIONEN (13 × 16)
- TGPSSTATUS (14 × 2)
- RES_0XA022 (2 × 13)
- ARG_0XA022 (1 × 14)
- TSELBSTTESTROUTINE (2 × 2)
- RES_0XA05E (51 × 13)
- ARG_0XA05E (1 × 14)
- TANTENNECEALL (5 × 2)
- TANTENNEFEHLERART (5 × 2)
- RES_0XA05F (2 × 13)
- ARG_0XA05F (1 × 14)
- TVERBAUCECALL (13 × 2)
- TTESTSTATUS (6 × 2)
- RES_0XA076 (1 × 13)
- ARG_0XA076 (1 × 14)
- RES_0XA079 (1 × 13)
- TRESETSTATUS (6 × 2)
- RES_0XA07A (3 × 13)
- TPROVISIONINGSTATUSECALL (6 × 2)
- ARG_0XA086 (3 × 14)
- TPOWERSTATENEC (12 × 2)
- TPOWEREVENTNEC (32 × 2)
- TPOWERSTATENAD (13 × 2)
- TPOWEREVENTNAD (12 × 2)
- TSTATEECALLLOG (33 × 2)
- TEVENTECALLLOG (36 × 2)
JOBRESULT
Dimensions: 66 rows × 2 columns
| SB | STATUS_TEXT |
|---|---|
| 0x10 | ERROR_ECU_GENERAL_REJECT |
| 0x11 | ERROR_ECU_SERVICE_NOT_SUPPORTED |
| 0x12 | ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED |
| 0x13 | ERROR_ECU_INCORRECT_MESSAGE_LENGTH_OR_INVALID_FORMAT |
| 0x14 | ERROR_ECU_RESPONSE_TOO_LONG |
| 0x21 | ERROR_ECU_BUSY_REPEAT_REQUEST |
| 0x22 | ERROR_ECU_CONDITIONS_NOT_CORRECT |
| 0x24 | ERROR_ECU_REQUEST_SEQUENCE_ERROR |
| 0x25 | ERROR_ECU_NO_RESPONSE_FROM_SUBNET_COMPONENT |
| 0x26 | ERROR_ECU_FAILURE_PREVENTS_EXECUTION_OF_REQUESTED_ACTION |
| 0x31 | ERROR_ECU_REQUEST_OUT_OF_RANGE |
| 0x33 | ERROR_ECU_SECURITY_ACCESS_DENIED |
| 0x35 | ERROR_ECU_INVALID_KEY |
| 0x36 | ERROR_ECU_EXCEED_NUMBER_OF_ATTEMPTS |
| 0x37 | ERROR_ECU_REQUIRED_TIME_DELAY_NOT_EXPIRED |
| 0x70 | ERROR_ECU_UPLOAD_DOWNLOAD_NOT_ACCEPTED |
| 0x71 | ERROR_ECU_TRANSFER_DATA_SUSPENDED |
| 0x72 | ERROR_ECU_GENERAL_PROGRAMMING_FAILURE |
| 0x73 | ERROR_ECU_WRONG_BLOCK_SEQUENCE_COUNTER |
| 0x78 | ERROR_ECU_REQUEST_CORRECTLY_RECEIVED__RESPONSE_PENDING |
| 0x7E | ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED_IN_ACTIVE_SESSION |
| 0x7F | ERROR_ECU_SERVICE_NOT_SUPPORTED_IN_ACTIVE_SESSION |
| 0x81 | ERROR_ECU_RPM_TOO_HIGH |
| 0x82 | ERROR_ECU_RPM_TOO_LOW |
| 0x83 | ERROR_ECU_ENGINE_IS_RUNNING |
| 0x84 | ERROR_ECU_ENGINE_IS_NOT_RUNNING |
| 0x85 | ERROR_ECU_ENGINE_RUN_TIME_TOO_LOW |
| 0x86 | ERROR_ECU_TEMPERATURE_TOO_HIGH |
| 0x87 | ERROR_ECU_TEMPERATURE_TOO_LOW |
| 0x88 | ERROR_ECU_VEHICLE_SPEED_TOO_HIGH |
| 0x89 | ERROR_ECU_VEHICLE_SPEED_TOO_LOW |
| 0x8A | ERROR_ECU_THROTTLE_PEDAL_TOO_HIGH |
| 0x8B | ERROR_ECU_THROTTLE_PEDAL_TOO_LOW |
| 0x8C | ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_NEUTRAL |
| 0x8D | ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_GEAR |
| 0x8F | ERROR_ECU_BRAKE_SWITCH_NOT_CLOSED |
| 0x90 | ERROR_ECU_SHIFTER_LEVER_NOT_IN_PARK |
| 0x91 | ERROR_ECU_TORQUE_CONVERTER_CLUTCH_LOCKED |
| 0x92 | ERROR_ECU_VOLTAGE_TOO_HIGH |
| 0x93 | ERROR_ECU_VOLTAGE_TOO_LOW |
| ?00? | OKAY |
| ?01? | ERROR_ECU_NO_RESPONSE |
| ?02? | ERROR_ECU_INCORRECT_LEN |
| ?03? | ERROR_ECU_INCORRECT_RESPONSE_ID |
| ?04? | ERROR_ECU_TA_RESPONSE_NOT_SA_REQUEST |
| ?05? | ERROR_ECU_SA_RESPONSE_NOT_TA_REQUEST |
| ?06? | ERROR_ECU_RESPONSE_INCORRECT_DATA_IDENTIFIER |
| ?07? | ERROR_ECU_RESPONSE_TOO_MUCH_DATA |
| ?08? | ERROR_ECU_RESPONSE_TOO_LESS_DATA |
| ?09? | ERROR_ECU_RESPONSE_VALUE_OUT_OF_RANGE |
| ?0A? | ERROR_TABLE |
| ?10? | ERROR_F_CODE |
| ?12? | ERROR_INTERPRETATION |
| ?13? | ERROR_F_POS |
| ?14? | ERROR_ECU_RESPONSE_INCORRECT_IO_CONTROL_PARAMETER |
| ?15? | ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_CONTROL_TYPE |
| ?16? | ERROR_ECU_RESPONSE_INCORRECT_SUB_FUNCTION |
| ?17? | ERROR_ECU_RESPONSE_INCORRECT_DYNAMICALLY_DEFINED_DATA_IDENTIFIER |
| ?18? | ERROR_ECU_RESPONSE_NO_STRING_END_CHAR |
| ?50? | ERROR_BYTE1 |
| ?51? | ERROR_BYTE2 |
| ?52? | ERROR_BYTE3 |
| ?80? | ERROR_SVK_INCORRECT_LEN |
| ?81? | ERROR_SVK_INCORRECT_FINGERPRINT |
| ?F0? | ERROR_ARGUMENT |
| 0xXY | ERROR_ECU_UNKNOWN_NEGATIVE_RESPONSE |
LIEFERANTEN
Dimensions: 121 rows × 2 columns
| LIEF_NR | LIEF_TEXT |
|---|---|
| 0x000001 | Reinshagen => Delphi |
| 0x000002 | Kostal |
| 0x000003 | Hella |
| 0x000004 | Siemens |
| 0x000005 | Eaton |
| 0x000006 | UTA |
| 0x000007 | Helbako |
| 0x000008 | Bosch |
| 0x000009 | Loewe => Lear |
| 0x000010 | VDO |
| 0x000011 | Valeo |
| 0x000012 | MBB |
| 0x000013 | Kammerer |
| 0x000014 | SWF |
| 0x000015 | Blaupunkt |
| 0x000016 | Philips |
| 0x000017 | Alpine |
| 0x000018 | Continental Teves |
| 0x000019 | Elektromatik Suedafrika |
| 0x000020 | Becker |
| 0x000021 | Preh |
| 0x000022 | Alps |
| 0x000023 | Motorola |
| 0x000024 | Temic |
| 0x000025 | Webasto |
| 0x000026 | MotoMeter |
| 0x000027 | Delphi PHI |
| 0x000028 | DODUCO => BERU |
| 0x000029 | DENSO |
| 0x000030 | NEC |
| 0x000031 | DASA |
| 0x000032 | Pioneer |
| 0x000033 | Jatco |
| 0x000034 | Fuba |
| 0x000035 | UK-NSI |
| 0x000036 | AABG |
| 0x000037 | Dunlop |
| 0x000038 | Sachs |
| 0x000039 | ITT |
| 0x000040 | FTE |
| 0x000041 | Megamos |
| 0x000042 | TRW |
| 0x000043 | Wabco |
| 0x000044 | ISAD Electronic Systems |
| 0x000045 | HEC (Hella Electronics Corporation) |
| 0x000046 | Gemel |
| 0x000047 | ZF |
| 0x000048 | GMPT |
| 0x000049 | Harman Kardon |
| 0x000050 | Remes |
| 0x000051 | ZF Lenksysteme |
| 0x000052 | Magneti Marelli |
| 0x000053 | Borg Instruments |
| 0x000054 | GETRAG |
| 0x000055 | BHTC (Behr Hella Thermocontrol) |
| 0x000056 | Siemens VDO Automotive |
| 0x000057 | Visteon |
| 0x000058 | Autoliv |
| 0x000059 | Haberl |
| 0x000060 | Magna Steyr |
| 0x000061 | Marquardt |
| 0x000062 | AB-Elektronik |
| 0x000063 | Siemens VDO Borg |
| 0x000064 | Hirschmann Electronics |
| 0x000065 | Hoerbiger Electronics |
| 0x000066 | Thyssen Krupp Automotive Mechatronics |
| 0x000067 | Gentex GmbH |
| 0x000068 | Atena GmbH |
| 0x000069 | Magna-Donelly |
| 0x000070 | Koyo Steering Europe |
| 0x000071 | NSI B.V |
| 0x000072 | AISIN AW CO.LTD |
| 0x000073 | Shorlock |
| 0x000074 | Schrader |
| 0x000075 | BERU Electronics GmbH |
| 0x000076 | CEL |
| 0x000077 | Audio Mobil |
| 0x000078 | rd electronic |
| 0x000079 | iSYS RTS GmbH |
| 0x000080 | Westfalia Automotive GmbH |
| 0x000081 | Tyco Electronics |
| 0x000082 | Paragon AG |
| 0x000083 | IEE S.A |
| 0x000084 | TEMIC AUTOMOTIVE of NA |
| 0x000085 | AKsys GmbH |
| 0x000086 | META System |
| 0x000087 | Hülsbeck & Fürst GmbH & Co KG |
| 0x000088 | Mann & Hummel Automotive GmbH |
| 0x000089 | Brose Fahrzeugteile GmbH & Co |
| 0x000090 | Keihin |
| 0x000091 | Vimercati S.p.A. |
| 0x000092 | CRH |
| 0x000093 | TPO Display Corp. |
| 0x000094 | KÜSTER Automotive Control |
| 0x000095 | Hitachi Automotive |
| 0x000096 | Continental Automotive |
| 0x000097 | TI-Automotive |
| 0x000098 | Hydro |
| 0x000099 | Johnson Controls |
| 0x00009A | Takata- Petri |
| 0x00009B | Mitsubishi Electric B.V. (Melco) |
| 0x00009C | Autokabel |
| 0x00009D | GKN-Driveline |
| 0x00009E | Zollner Elektronik AG |
| 0x00009F | PEIKER acustics GmbH |
| 0x0000A0 | Bosal-Oris |
| 0x0000A1 | Cobasys |
| 0x0000A2 | Lighting Reutlingen GmbH |
| 0x0000A3 | CONTI VDO |
| 0x0000A4 | ADC Automotive Distance Control Systems GmbH |
| 0x0000A5 | Funkwerk Dabendorf GmbH |
| 0x0000A6 | Lame |
| 0x0000A7 | Magna/Closures |
| 0x0000A8 | Wanyu |
| 0x0000A9 | Thyssen Krupp Presta |
| 0x0000AA | ArvinMeritor |
| 0x0000AB | Kongsberg Automotive GmbH |
| 0x0000AC | SMR Automotive Mirrors |
| 0x0000AD | So.Ge.Mi. |
| 0x0000AE | MTA |
| 0xFFFFFF | unbekannter Hersteller |
FARTTEXTE
Dimensions: 19 rows × 2 columns
| ARTNR | ARTTEXT |
|---|---|
| 0x00 | keine Fehlerart verfügbar |
| 0x04 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x05 | Fehler momentan vorhanden und bereits gespeichert |
| 0x08 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x09 | Fehler momentan vorhanden und bereits gespeichert |
| 0x0C | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x0D | Fehler momentan vorhanden und bereits gespeichert |
| 0x40 | unbekannte Fehlerart |
| 0x44 | Fehler gespeichert |
| 0x45 | Fehler gespeichert |
| 0x48 | Fehler gespeichert |
| 0x49 | Fehler gespeichert |
| 0x4C | Fehler gespeichert |
| 0x4D | Fehler gespeichert |
| 0x10 | Testbedingungen erfüllt |
| 0x11 | Testbedingungen noch nicht erfüllt |
| 0x80 | Fehler würde kein Aufleuchten einer Warnlampe verursachen |
| 0x81 | Fehler würde das Aufleuchten einer Warnlampe verursachen |
| 0xFF | unbekannte Fehlerart |
DIGITALARGUMENT
Dimensions: 17 rows × 2 columns
| TEXT | WERT |
|---|---|
| ein | 1 |
| aus | 0 |
| ja | 1 |
| nein | 0 |
| auf | 1 |
| ab | 0 |
| an | 1 |
| yes | 1 |
| no | 0 |
| on | 1 |
| off | 0 |
| up | 1 |
| down | 0 |
| true | 1 |
| false | 0 |
| 1 | 1 |
| 0 | 0 |
PROZESSKLASSEN
Dimensions: 24 rows × 3 columns
| WERT | PROZESSKLASSE | BEZEICHNUNG |
|---|---|---|
| 0x00 | - | ungueltig |
| 0x01 | HWEL | Hardware (Elektronik) |
| 0x02 | HWAP | Hardwareauspraegung |
| 0x03 | HWFR | Hardwarefarbe |
| 0x05 | CAFD | Codierdaten |
| 0x06 | BTLD | Bootloader |
| 0x08 | SWFL | Software ECU Speicherimage |
| 0x09 | SWFF | Flash File Software |
| 0x0A | SWPF | Pruefsoftware |
| 0x0B | ONPS | Onboard Programmiersystem |
| 0x0F | FAFP | FA2FP |
| 0x1A | TLRT | Temporaere Loeschroutine |
| 0x1B | TPRG | Temporaere Programmierroutine |
| 0x07 | FLSL | Flashloader Slave |
| 0x0C | IBAD | Interaktive Betriebsanleitung Daten |
| 0x10 | FCFA | Freischaltcode Fahrzeug-Auftrag |
| 0x1C | BLUP | Bootloader-Update Applikation |
| 0x1D | FLUP | Flashloader-Update Applikation |
| 0xA0 | ENTD | Entertainment Daten |
| 0xA1 | NAVD | Navigation Daten |
| 0xA2 | FCFN | Freischaltcode Funktion |
| 0xC0 | SWUP | Software-Update Package |
| 0xC1 | SWIP | Index Software-Update Package |
| 0xFF | - | ungueltig |
SVK_ID
Dimensions: 65 rows × 2 columns
| WERT | BEZEICHNUNG |
|---|---|
| 0x01 | SVK_AKTUELL |
| 0x02 | SVK_SUPPLIER |
| 0x03 | SVK_WERK |
| 0x04 | SVK_BACKUP_01 |
| 0x05 | SVK_BACKUP_02 |
| 0x06 | SVK_BACKUP_03 |
| 0x07 | SVK_BACKUP_04 |
| 0x08 | SVK_BACKUP_05 |
| 0x09 | SVK_BACKUP_06 |
| 0x0A | SVK_BACKUP_07 |
| 0x0B | SVK_BACKUP_08 |
| 0x0C | SVK_BACKUP_09 |
| 0x0D | SVK_BACKUP_10 |
| 0x0E | SVK_BACKUP_11 |
| 0x0F | SVK_BACKUP_12 |
| 0x10 | SVK_BACKUP_13 |
| 0x11 | SVK_BACKUP_14 |
| 0x12 | SVK_BACKUP_15 |
| 0x13 | SVK_BACKUP_16 |
| 0x14 | SVK_BACKUP_17 |
| 0x15 | SVK_BACKUP_18 |
| 0x16 | SVK_BACKUP_19 |
| 0x17 | SVK_BACKUP_20 |
| 0x18 | SVK_BACKUP_21 |
| 0x19 | SVK_BACKUP_22 |
| 0x1A | SVK_BACKUP_23 |
| 0x1B | SVK_BACKUP_24 |
| 0x1C | SVK_BACKUP_25 |
| 0x1D | SVK_BACKUP_26 |
| 0x1E | SVK_BACKUP_27 |
| 0x1F | SVK_BACKUP_28 |
| 0x20 | SVK_BACKUP_29 |
| 0x21 | SVK_BACKUP_30 |
| 0x22 | SVK_BACKUP_31 |
| 0x23 | SVK_BACKUP_32 |
| 0x24 | SVK_BACKUP_33 |
| 0x25 | SVK_BACKUP_34 |
| 0x26 | SVK_BACKUP_35 |
| 0x27 | SVK_BACKUP_36 |
| 0x28 | SVK_BACKUP_37 |
| 0x29 | SVK_BACKUP_38 |
| 0x2A | SVK_BACKUP_39 |
| 0x2B | SVK_BACKUP_40 |
| 0x2C | SVK_BACKUP_41 |
| 0x2D | SVK_BACKUP_42 |
| 0x2E | SVK_BACKUP_43 |
| 0x2F | SVK_BACKUP_44 |
| 0x30 | SVK_BACKUP_45 |
| 0x31 | SVK_BACKUP_46 |
| 0x32 | SVK_BACKUP_47 |
| 0x33 | SVK_BACKUP_48 |
| 0x34 | SVK_BACKUP_49 |
| 0x35 | SVK_BACKUP_50 |
| 0x36 | SVK_BACKUP_51 |
| 0x37 | SVK_BACKUP_52 |
| 0x38 | SVK_BACKUP_53 |
| 0x39 | SVK_BACKUP_54 |
| 0x3A | SVK_BACKUP_55 |
| 0x3B | SVK_BACKUP_56 |
| 0x3C | SVK_BACKUP_57 |
| 0x3D | SVK_BACKUP_58 |
| 0x3E | SVK_BACKUP_59 |
| 0x3F | SVK_BACKUP_60 |
| 0x40 | SVK_BACKUP_61 |
| 0xXY | ERROR_UNKNOWN |
DTCEXTENDEDDATARECORDNUMBER
Dimensions: 5 rows × 3 columns
| WERT | TEXT | ANZ_BYTE |
|---|---|---|
| 0x00 | ISO_RESERVED | 0 |
| 0x01 | CONDITION_BYTE | 1 |
| 0x02 | HFK | 1 |
| 0x03 | HLZ | 1 |
| 0xFF | RECORD_UNKNOWN | 0 |
DTCSNAPSHOTIDENTIFIER
Dimensions: 5 rows × 9 columns
| UWNR | UWTEXT | UW_EINH | L/H | UWTYP | NAME | MUL | DIV | ADD |
|---|---|---|---|---|---|---|---|---|
| 0x1700 | KM_STAND | 0-n | - | 0xFFFFFF | - | 1 | 1 | 0.000000 |
| 0x1701 | ABS_ZEIT | 0-n | - | 0xFFFFFFFF | - | 1 | 1 | 0.000000 |
| 0x1702 | SAE_CODE | 0-n | - | 0xFFFFFF | - | 1 | 1 | 0.000000 |
| 0x1731 | Fehlerklasse_DTC | - | - | u char | - | 1 | 1 | 0.000000 |
| 0xFFFF | IDENTIFIER_UNKNOWN | - | - | 0xFFFFFF | - | 1 | 1 | 0.000000 |
FEHLERKLASSE
Dimensions: 5 rows × 2 columns
| NR | TEXT |
|---|---|
| 0x00 | Keine Fehlerklasse verfuegbar |
| 0x01 | Ueberpruefung bei naechstem Werkstattbesuch |
| 0x02 | Ueberpruefung bei naechstem Halt |
| 0x04 | Ueberpruefung sofort erforderlich ! |
| 0xFF | unbekannte Fehlerklasse |
DIAGMODE
Dimensions: 11 rows × 3 columns
| NR | MODE | MODE_TEXT |
|---|---|---|
| 0x00 | UNGUELTIG | DefaultMode |
| 0x01 | DEFAULT | DefaultMode |
| 0x02 | ECUPM | ECUProgrammingMode |
| 0x03 | ECUEXTDIAG | ECUExtendedDiagnosticSession |
| 0x04 | ECUSSDS | ECUSafetySystemDiagnosticSession |
| 0x40 | ECUEOL | ECUEndOfLineSession |
| 0x41 | ECUCODE | ECUCodingSession |
| 0x42 | ECUSWT | ECUSwtSession |
| 0x43 | ECUHDD | ECUHDDDownloadSession |
| 0x4F | ECUDEVELOP | ECUDevelopmentSession |
| 0xXY | -- | unbekannter Diagnose-Mode |
IARTTEXTE
Dimensions: 18 rows × 2 columns
| ARTNR | ARTTEXT |
|---|---|
| 0x00 | keine Fehlerart verfügbar |
| 0x04 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x05 | Fehler momentan vorhanden und bereits gespeichert |
| 0x08 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x09 | Fehler momentan vorhanden und bereits gespeichert |
| 0x0C | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x0D | Fehler momentan vorhanden und bereits gespeichert |
| 0x44 | Fehler gespeichert |
| 0x45 | Fehler gespeichert |
| 0x48 | Fehler gespeichert |
| 0x49 | Fehler gespeichert |
| 0x4C | Fehler gespeichert |
| 0x4D | Fehler gespeichert |
| 0x10 | Testbedingungen erfüllt |
| 0x11 | Testbedingungen noch nicht erfüllt |
| 0x80 | Fehler würde kein Aufleuchten einer Warnlampe verursachen |
| 0x81 | Fehler würde das Aufleuchten einer Warnlampe verursachen |
| 0xFF | unbekannte Fehlerart |
UDS_TAB_ROE_AKTIV
Dimensions: 3 rows × 2 columns
| NR | TEXT |
|---|---|
| 0x00 | Aktive Fehlermeldung deaktiviert |
| 0x01 | Aktive Fehlermeldung aktiviert |
| 0xFF | Status der aktiven Fehlermeldung nicht feststellbar |
JOBRESULTEXTENDED
Dimensions: 1 rows × 2 columns
| SB | STATUS_TEXT |
|---|---|
| 0xXY | ERROR_UNKNOWN |
BETRIEBSMODE
Dimensions: 2 rows × 3 columns
| WERT | TEXT | BEDEUTUNG |
|---|---|---|
| 0x00 | kein Betriebsmode gesetzt | kein Betriebsmode |
| 0xFF | ungültiger Betriebsmode | ungültig |
FORTTEXTE
Dimensions: 52 rows × 3 columns
| ORT | ORTTEXT | EREIGNIS_DTC |
|---|---|---|
| 0x026100 | Energiesparmode aktiv | 0 |
| 0x02FF61 | Dummy-Fehlerspeichereintrag im Komponentenfehlerbereich nur für Testzwecke | 1 |
| 0xB7F301 | Codierung: Steuergerät ist nicht codiert | 0 |
| 0xB7F302 | Codierung: Fehler bei Codierung aufgetreten | 0 |
| 0xB7F303 | Codierung: Signatur für Daten ungültig | 0 |
| 0xB7F304 | Codierung: Codierung passt nicht zum Fahrzeug | 0 |
| 0xB7F305 | Codierung: Unplausible Daten während Transaktion | 0 |
| 0xB7F306 | Speicherfehler (NVM_E_WRITE_FAILED) | 0 |
| 0xB7F307 | Speicherfehler (NVM_E_READ_FAILED) | 0 |
| 0xB7F308 | Speicherfehler (NVM_E_CONTROL_FAILED) | 0 |
| 0xB7F309 | Speicherfehler (NVM_E_ERASE_FAILED) | 0 |
| 0xB7F30A | Speicherfehler (NVM_E_WRITE_ALL_FAILED) | 0 |
| 0xB7F30B | Speicherfehler (NVM_E_WRONG_CONFIG_ID) | 0 |
| 0xB7F30C | Speicherfehler (NVM_E_READ_ALL_FAILED) | 0 |
| 0xB7F30D | Keine Kommunikation mit GPS-Empfänger | 0 |
| 0xB7F30F | Keine Kommunikation mit internem Empfangsmodul | 0 |
| 0xB7F311 | Kein Zugriff auf interne SIM-Karte | 0 |
| 0xB7F313 | SIM-Karte gesperrt | 0 |
| 0xB7F314 | SIM-Karte nicht freigeschaltet | 0 |
| 0xB7F315 | GPS-Antenne: Kurzschluss nach Plus | 0 |
| 0xB7F316 | GPS-Antenne: Unterbrechung | 0 |
| 0xB7F318 | Notruf-LED Fehler | 0 |
| 0xB7F319 | Notruf-Taster: Kurzschluss | 0 |
| 0xB7F31A | Notruf-Taster: Unterbrechung | 0 |
| 0xB7F31B | Mikrofon 1: Kurzschluss nach Plus | 0 |
| 0xB7F31C | Mikrofon 2: Kurzschluss nach Plus | 0 |
| 0xB7F31D | GSM-Backup-Antenne: Kurzschluss nach Plus | 0 |
| 0xB7F31E | GSM-Antenne: Kurzschluss nach Plus | 0 |
| 0xB7F31F | GSM-Antenne: Kurzschluss nach Masse | 0 |
| 0xB7F320 | Hardware Reset | 0 |
| 0xB7F321 | Software Reset | 0 |
| 0xB7F322 | Alive Signal Airbag fehlt beim Aufstart | 1 |
| 0xB7F323 | Alive Signal Airbag fehlerhaft | 1 |
| 0xB7F324 | Notruf-Lautsprecher: Kurzschluss nach Plus | 0 |
| 0xB7F325 | Notruf-Lautsprecher: Unterbrechung | 0 |
| 0xB7F326 | Notruf-Lautsprecher: Kurzschluss nach Masse | 0 |
| 0xB7F327 | Mikrofon 1: Kurzschluss nach Masse | 0 |
| 0xB7F328 | Mikrofon 1: Unterbrechung | 0 |
| 0xB7F329 | Mikrofon 2: Kurzschluss nach Masse | 0 |
| 0xB7F32A | Mikrofon 2: Unterbrechung | 0 |
| 0xB7F32B | GSM-Antenne: Unterbrechung | 0 |
| 0xB7F32C | GSM-Backup-Antenne: Kurzschluss nach Masse | 0 |
| 0xB7F32D | GSM-Backup-Antenne: Unterbrechung | 0 |
| 0xB7F330 | Speicherfehler (FLS_E_EREASE_FAILED) | 0 |
| 0xB7F331 | Speicherfehler (FLS_E_WRITE_FAILED) | 0 |
| 0xB7F332 | Speicherfehler (FLS_E_READ_FAILED) | 0 |
| 0xB7F333 | Speicherfehler (FLS_E_COMPARE_FAILED) | 0 |
| 0xB7F334 | Aufstart aus unbekanntem Grund | 0 |
| 0xE1445F | BODY-CAN Physikalischer Busfehler | 0 |
| 0xE14468 | BODY-CAN Control Module Bus OFF | 0 |
| 0xE14BFF | Dummy-Fehlerspeichereintrag im Netzwerkfehlerbereich nur fuer Testzwecke | 1 |
| 0xFFFFFF | unbekannter Fehlerort | 0 |
FDETAILSTRUKTUR
Dimensions: 6 rows × 2 columns
| NAME | TYP |
|---|---|
| F_UWB_ERW | nein |
| SAE_CODE | nein |
| F_HLZ | ja |
| F_SEVERITY | nein |
| F_UWB_SATZ | 2 |
| F_HLZ_VIEW | - |
IORTTEXTE
Dimensions: 6 rows × 3 columns
| ORT | ORTTEXT | EREIGNIS_DTC |
|---|---|---|
| 0x619400 | VSM_EVENT_VEHICLESTATE | 0 |
| 0x61A000 | ECALL_ASSIST_DISABLED | 0 |
| 0x61A001 | ECALL_ASSIST_NOT_AVAILABLE | 0 |
| 0x61A002 | ECALL_TRIGGERED | 0 |
| 0x61A003 | SIM-Karte nicht freigeschaltet | 0 |
| 0xFFFFFF | unbekannter Fehlerort | 0 |
IDETAILSTRUKTUR
Dimensions: 4 rows × 2 columns
| NAME | TYP |
|---|---|
| F_UWB_ERW | nein |
| SAE_CODE | nein |
| F_HLZ | ja |
| F_SEVERITY | nein |
SG_FUNKTIONEN
Dimensions: 13 rows × 16 columns
| ARG | ID | RESULTNAME | INFO | EINHEIT | LABEL | L/H | DATENTYP | NAME | MUL | DIV | ADD | SG_ADR | SERVICE | ARG_TABELLE | RES_TABELLE |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ECALL_ENABLE | 0xA076 | - | Notruf (Ecall) einschalten bzw. ausschalten | - | - | - | - | - | - | - | - | - | 31 | ARG_0xA076 | RES_0xA076 |
| PROVISIONING_ECALL | 0xA07A | - | Status des Provisionierungsprozess | - | - | - | - | - | - | - | - | - | 31 | - | RES_0xA07A |
| RESET_TO_DEFAULTCONFIG | 0xA079 | - | Setzt die standard Telematik Konfigurationswerte zurück und löscht die OTA (Over The Air) Daten | - | - | - | - | - | - | - | - | - | 31 | - | RES_0xA079 |
| SELBSTTEST | 0xA022 | - | Selbsttests des Steuergerätes Sie sollen einen evtl. notwendigen Tausch von Software/Hardware erkennen. | - | - | - | - | - | - | - | - | - | 31 | ARG_0xA022 | RES_0xA022 |
| STATUS_GPS | 0xD038 | STAT_GPS | Rückgabe des GPS-Status. | 0-n | - | - | unsigned char | TGpsStatus | - | - | - | - | 22 | - | - |
| STATUS_GPS_RECEIVER_SW_VERSION | 0xD03B | STAT_GPS_RECEIVER_SW_VERSION_WERT | not defined in diagnosis database | - | - | - | string | - | - | - | - | - | 22 | - | - |
| STATUS_ICC_ID_LESEN | 0xD05A | STAT_ICC_ID_WERT | Auslesen des ICC (Integrated Circuit Card) -ID des internen Telefonmoduls | - | - | - | string | - | - | - | - | - | 22 | - | - |
| STATUS_IMEI_LESEN | 0xD06B | STAT_IMEI_WERT | Auslesen des IMEI (International Mobile Equipment Identity) des internen Telefonmoduls | - | - | - | string | - | - | - | - | - | 22 | - | - |
| STATUS_NAD_FIRMWARE_VERSION | 0xD06D | STAT_NAD_FIRMWARE_VERSION_WERT | Auslesen der Firmware Version des NAD (Network Access Module) | - | - | - | string | - | - | - | - | - | 22 | - | - |
| STATUS_NAD_USERWARE_VERSION | 0xD06E | STAT_NAD_USERWARE_VERSION_WERT | Auslesen der Userware Version des NAD (Network Access Module) | - | - | - | string | - | - | - | - | - | 22 | - | - |
| STEUERN_SOS_SPEAKER_TEST | 0xA086 | - | Spielt einen Ton mit parametrierbarer Frequenz, Dauer, Lautstärke | - | - | - | - | - | - | - | - | - | 31 | ARG_0xA086 | - |
| TEST_ANTENNE_ECALL | 0xA05E | - | Startet und bewertet die Prüfung für eine oder mehrere Antennen. | - | - | - | - | - | - | - | - | - | 31 | ARG_0xA05E | RES_0xA05E |
| TEST_VERBAU_ECALL | 0xA05F | - | Test Verbau CECALL | - | - | - | - | - | - | - | - | - | 31 | ARG_0xA05F | RES_0xA05F |
TGPSSTATUS
Dimensions: 14 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00 | Nicht unterstuetzt: Kein GPS |
| 0x01 | Nicht unterstuetzt: Kommunikationsfehler |
| 0x02 | Receiverfehler |
| 0x03 | Kein almanac |
| 0x04 | Suche Satelliten |
| 0x05 | Ortung Satellit 1 |
| 0x06 | Ortung Satellit 2 |
| 0x07 | Ortung Satellit 3 |
| 0x08 | Ortung Satellit 4 |
| 0x09 | Ortung Satellit 5 |
| 0x0A | Ortung Satellit 6 |
| 0x0B | 2D Position |
| 0x0C | 3D Position |
| 0xFF | Nicht definiert |
RES_0XA022
Dimensions: 2 rows × 13 columns
| RESULTNAME | STR | STPR | RRR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| STAT_SELBSTTEST_ROUTINE | - | - | + | 0-n | - | unsigned long | - | TSelbsttestRoutine | - | - | - | Routine(n), die getestet wurde(n). Tabelle TSelbsttestRoutine |
| STAT_SELBSTTEST | - | - | + | 0-n | - | unsigned char | - | TTestStatus | - | - | - | Gibt den Status des Tests wieder. |
ARG_0XA022
Dimensions: 1 rows × 14 columns
| ARG | STR | STPR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ARG_SELBSTTEST_ROUTINE | + | - | - | - | unsigned long | - | - | - | - | - | - | - | Routinen, die getestet werden sollen. Die Tabelle TSelbsttestRoutine wird in der SGBD von der Entwicklung bzw. vom Zulieferer befüllt und gepflegt. |
TSELBSTTESTROUTINE
Dimensions: 2 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00000000 | Alle Routinen |
| 0xFFFFFFFF | Nicht definiert |
RES_0XA05E
Dimensions: 51 rows × 13 columns
| RESULTNAME | STR | STPR | RRR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| STAT_ANTENNE | - | - | + | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | gibt an, welche Antenne(n) getestet wurden. |
| STAT_TEST_ANTENNE | - | - | + | 0-n | - | unsigned char | - | TTestStatus | - | - | - | Gibt den Status des gesamten Tests oder der entsprechenden Antennen wieder. Nach dem Herunterfahren oder Neustart des Steuergerätes wird der Status automatisch auf 0 zurückgesetzt. |
| STAT_ANZAHL_FEHLERHAFTE_ANTENNEN_WERT | - | - | + | - | - | unsigned char | - | - | - | - | - | Dieses Result wird mit 255 belegt, wenn STAT_TEST_ANTENNE nicht den Wert 2 oder 3 meldet. Gibt wieder, wie viele Fehler während des Tests gefunden wurden. |
| STAT_FEHLER_1_ANTENNE | - | - | + | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | Rückgabe der Antenne, bei der der Fehler X auftrat. Dieses Result wird mit 0xFFFFFFFF belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet oder die Antenne nicht existiert. |
| STAT_FEHLER_1_FEHLERART_ANTENNE | - | - | + | 0-n | - | unsigned char | - | TAntenneFehlerArt | - | - | - | Dieses Result wird mit 255 belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet. |
| STAT_FEHLER_1_MESSWERT_WIDERSTAND_WERT | - | - | + | 0,1kOhm | - | unsigned int | - | - | - | - | - | der auf der fehlerhaften Antenne X gemessene Widerstand in 0.1 kOhm. |
| STAT_FEHLER_2_ANTENNE | - | - | + | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | gibt die Antenne wieder, bei der der Fehler X auftrat. Dieses Result wird mit 0xFFFFFFFF belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet oder die Antenne nicht existiert. |
| STAT_FEHLER_2_FEHLERART_ANTENNE | - | - | + | 0-n | - | unsigned char | - | TAntenneFehlerArt | - | - | - | Dieses Result wird mit 255 belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet. |
| STAT_FEHLER_2_MESSWERT_WIDERSTAND_WERT | - | - | + | 0,1kOhm | - | unsigned int | - | - | - | - | - | der auf der fehlerhaften Antenne X gemessene Widerstand in 0.1 kOhm. |
| STAT_FEHLER_3_ANTENNE | - | - | + | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | gibt die Antenne wieder, bei der der Fehler X auftrat. Dieses Result wird mit 0xFFFFFFFF belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet oder die Antenne nicht existiert. |
| STAT_FEHLER_3_FEHLERART_ANTENNE | - | - | + | 0-n | - | unsigned char | - | TAntenneFehlerArt | - | - | - | Dieses Result wird mit 255 belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet. |
| STAT_FEHLER_3_MESSWERT_WIDERSTAND_WERT | - | - | + | 0,1kOhm | - | unsigned int | - | - | - | - | - | der auf der fehlerhaften Antenne X gemessene Widerstand in 0.1 kOhm. |
| STAT_FEHLER_4_ANTENNE | - | - | + | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | gibt die Antenne wieder, bei der der Fehler X auftrat. Dieses Result wird mit 0xFFFFFFFF belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet oder die Antenne nicht existiert. |
| STAT_FEHLER_4_FEHLERART_ANTENNE | - | - | + | 0-n | - | unsigned char | - | TAntenneFehlerArt | - | - | - | Dieses Result wird mit 255 belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet. |
| STAT_FEHLER_4_MESSWERT_WIDERSTAND_WERT | - | - | + | 0,1kOhm | - | unsigned int | - | - | - | - | - | der auf der fehlerhaften Antenne X gemessene Widerstand in 0.1 kOhm. |
| STAT_FEHLER_5_ANTENNE | - | - | + | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | gibt die Antenne wieder, bei der der Fehler X auftrat. Dieses Result wird mit 0xFFFFFFFF belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet oder die Antenne nicht existiert. |
| STAT_FEHLER_5_FEHLERART_ANTENNE | - | - | + | 0-n | - | unsigned char | - | TAntenneFehlerArt | - | - | - | Dieses Result wird mit 255 belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet. |
| STAT_FEHLER_5_MESSWERT_WIDERSTAND_WERT | - | - | + | 0,1kOhm | - | unsigned int | - | - | - | - | - | der auf der fehlerhaften Antenne X gemessene Widerstand in 0.1 kOhm. |
| STAT_FEHLER_6_ANTENNE | - | - | + | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | gibt die Antenne wieder, bei der der Fehler X auftrat. Dieses Result wird mit 0xFFFFFFFF belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet oder die Antenne nicht existiert. |
| STAT_FEHLER_6_FEHLERART_ANTENNE | - | - | + | 0-n | - | unsigned char | - | TAntenneFehlerArt | - | - | - | Dieses Result wird mit 255 belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet. |
| STAT_FEHLER_6_MESSWERT_WIDERSTAND_WERT | - | - | + | 0,1kOhm | - | unsigned int | - | - | - | - | - | der auf der fehlerhaften Antenne X gemessene Widerstand in 0.1 kOhm. |
| STAT_FEHLER_7_ANTENNE | - | - | + | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | gibt die Antenne wieder, bei der der Fehler X auftrat. Dieses Result wird mit 0xFFFFFFFF belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet oder die Antenne nicht existiert. |
| STAT_FEHLER_7_FEHLERART_ANTENNE | - | - | + | 0-n | - | unsigned char | - | TAntenneFehlerArt | - | - | - | Dieses Result wird mit 255 belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet. |
| STAT_FEHLER_7_MESSWERT_WIDERSTAND_WERT | - | - | + | 0,1kOhm | - | unsigned int | - | - | - | - | - | der auf der fehlerhaften Antenne X gemessene Widerstand in 0.1 kOhm. |
| STAT_FEHLER_8_ANTENNE | - | - | + | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | gibt die Antenne wieder, bei der der Fehler X auftrat. Dieses Result wird mit 0xFFFFFFFF belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet oder die Antenne nicht existiert. |
| STAT_FEHLER_8_FEHLERART_ANTENNE | - | - | + | 0-n | - | unsigned char | - | TAntenneFehlerArt | - | - | - | Dieses Result wird mit 255 belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet. |
| STAT_FEHLER_8_MESSWERT_WIDERSTAND_WERT | - | - | + | 0,1kOhm | - | unsigned int | - | - | - | - | - | der auf der fehlerhaften Antenne X gemessene Widerstand in 0.1 kOhm. |
| STAT_FEHLER_9_ANTENNE | - | - | + | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | gibt die Antenne wieder, bei der der Fehler X auftrat. Dieses Result wird mit 0xFFFFFFFF belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet oder die Antenne nicht existiert. |
| STAT_FEHLER_9_FEHLERART_ANTENNE | - | - | + | 0-n | - | unsigned char | - | TAntenneFehlerArt | - | - | - | Dieses Result wird mit 255 belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet. |
| STAT_FEHLER_9_MESSWERT_WIDERSTAND_WERT | - | - | + | 0,1kOhm | - | unsigned int | - | - | - | - | - | der auf der fehlerhaften Antenne X gemessene Widerstand in 0.1 kOhm. |
| STAT_FEHLER_10_ANTENNE | - | - | + | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | gibt die Antenne wieder, bei der der Fehler X auftrat. Dieses Result wird mit 0xFFFFFFFF belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet oder die Antenne nicht existiert. |
| STAT_FEHLER_10_FEHLERART_ANTENNE | - | - | + | 0-n | - | unsigned char | - | TAntenneFehlerArt | - | - | - | Dieses Result wird mit 255 belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet. |
| STAT_FEHLER_10_MESSWERT_WIDERSTAND_WERT | - | - | + | 0,1kOhm | - | unsigned int | - | - | - | - | - | der auf der fehlerhaften Antenne X gemessene Widerstand in 0.1 kOhm. |
| STAT_FEHLER_11_ANTENNE | - | - | + | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | gibt die Antenne wieder, bei der der Fehler X auftrat. Dieses Result wird mit 0xFFFFFFFF belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet oder die Antenne nicht existiert. |
| STAT_FEHLER_11_FEHLERART_ANTENNE | - | - | + | 0-n | - | unsigned char | - | TAntenneFehlerArt | - | - | - | Dieses Result wird mit 255 belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet. |
| STAT_FEHLER_11_MESSWERT_WIDERSTAND_WERT | - | - | + | 0,1kOhm | - | unsigned int | - | - | - | - | - | der auf der fehlerhaften Antenne X gemessene Widerstand in 0.1 kOhm. |
| STAT_FEHLER_12_ANTENNE | - | - | + | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | gibt die Antenne wieder, bei der der Fehler X auftrat. Dieses Result wird mit 0xFFFFFFFF belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet oder die Antenne nicht existiert. |
| STAT_FEHLER_12_FEHLERART_ANTENNE | - | - | + | 0-n | - | unsigned char | - | TAntenneFehlerArt | - | - | - | Dieses Result wird mit 255 belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet. |
| STAT_FEHLER_12_MESSWERT_WIDERSTAND_WERT | - | - | + | 0,1kOhm | - | unsigned int | - | - | - | - | - | der auf der fehlerhaften Antenne X gemessene Widerstand in 0.1 kOhm. |
| STAT_FEHLER_13_ANTENNE | - | - | + | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | gibt die Antenne wieder, bei der der Fehler X auftrat. Dieses Result wird mit 0xFFFFFFFF belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet oder die Antenne nicht existiert. |
| STAT_FEHLER_13_FEHLERART_ANTENNE | - | - | + | 0-n | - | unsigned char | - | TAntenneFehlerArt | - | - | - | Dieses Result wird mit 255 belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet. |
| STAT_FEHLER_13_MESSWERT_WIDERSTAND_WERT | - | - | + | 0,1kOhm | - | unsigned int | - | - | - | - | - | der auf der fehlerhaften Antenne X gemessene Widerstand in 0.1 kOhm. |
| STAT_FEHLER_14_ANTENNE | - | - | + | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | gibt die Antenne wieder, bei der der Fehler X auftrat. Dieses Result wird mit 0xFFFFFFFF belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet oder die Antenne nicht existiert. |
| STAT_FEHLER_14_FEHLERART_ANTENNE | - | - | + | 0-n | - | unsigned char | - | TAntenneFehlerArt | - | - | - | Dieses Result wird mit 255 belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet. |
| STAT_FEHLER_14_MESSWERT_WIDERSTAND_WERT | - | - | + | 0,1kOhm | - | unsigned int | - | - | - | - | - | der auf der fehlerhaften Antenne X gemessene Widerstand in 0.1 kOhm. |
| STAT_FEHLER_15_ANTENNE | - | - | + | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | gibt die Antenne wieder, bei der der Fehler X auftrat. Dieses Result wird mit 0xFFFFFFFF belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet oder die Antenne nicht existiert. |
| STAT_FEHLER_15_FEHLERART_ANTENNE | - | - | + | 0-n | - | unsigned char | - | TAntenneFehlerArt | - | - | - | Dieses Result wird mit 255 belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet. |
| STAT_FEHLER_15_MESSWERT_WIDERSTAND_WERT | - | - | + | 0,1kOhm | - | unsigned int | - | - | - | - | - | der auf der fehlerhaften Antenne X gemessene Widerstand in 0.1 kOhm. |
| STAT_FEHLER_16_ANTENNE | - | - | + | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | gibt die Antenne wieder, bei der der Fehler X auftrat. Dieses Result wird mit 0xFFFFFFFF belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet oder die Antenne nicht existiert. |
| STAT_FEHLER_16_FEHLERART_ANTENNE | - | - | + | 0-n | - | unsigned char | - | TAntenneFehlerArt | - | - | - | Dieses Result wird mit 255 belegt, wenn STAT_TEST_ANTENNE nicht den Wert 3 (Fehler) meldet. |
| STAT_FEHLER_16_MESSWERT_WIDERSTAND_WERT | - | - | + | 0,1kOhm | - | unsigned int | - | - | - | - | - | der auf der fehlerhaften Antenne X gemessene Widerstand in 0.1 kOhm. |
ARG_0XA05E
Dimensions: 1 rows × 14 columns
| ARG | STR | STPR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ARG_ANTENNE | + | - | 0-n | - | unsigned long | - | TAntenneCEALL | - | - | - | 0.0 | - | Antenne(n) die getestet werden sollen. Tabelle TAntenneCEALL |
TANTENNECEALL
Dimensions: 5 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00000000 | Alle |
| 0x00000001 | GSM_Telematik |
| 0x00000002 | GSM_Backup |
| 0x00000004 | GPS_Antenne |
| 0xFFFFFFFF | nicht definiert |
TANTENNEFEHLERART
Dimensions: 5 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00 | Kurzschluss nach Plus |
| 0x01 | Kurzschluss nach Masse |
| 0x02 | Leitungsunterbrechung |
| 0x03 | Falscher Antennfuß oder Diversity |
| 0xFF | Nicht definiert |
RES_0XA05F
Dimensions: 2 rows × 13 columns
| RESULTNAME | STR | STPR | RRR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| STAT_VERBAU_ROUTINE | - | - | + | 0-n | - | unsigned long | - | TVerbauCECALL | - | - | - | Ausgeführte Testroutine(n). |
| STAT_TEST_VERBAU | - | - | + | 0-n | - | unsigned char | - | TTestStatus | - | - | - | Gibt den Status des Verbautests wieder. Nach dem Herunterfahren oder Neustart des Steuergerätes wird der Status automatisch auf 0 zurückgesetzt. |
ARG_0XA05F
Dimensions: 1 rows × 14 columns
| ARG | STR | STPR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ARG_VERBAU_ROUTINE | + | - | 0-n | - | unsigned long | - | TVerbauCECALL | - | - | - | - | - | Routinen, die getestet werden sollen. Tabelle TVerbauCECALL |
TVERBAUCECALL
Dimensions: 13 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00000000 | Alle |
| 0x00000001 | GSM-Telematik |
| 0x00000002 | GSM-Backup |
| 0x00000004 | GSM-Antenne |
| 0x00000008 | Backup-Lautsprecher |
| 0x00000010 | E-Call-Button |
| 0x00000020 | E-Call-LED |
| 0x00000040 | E-Batterie |
| 0x00000080 | Airbag-Leitung |
| 0x00000100 | Wakeup-Leitung-CAS |
| 0x00000200 | Mikrophon1 |
| 0x00000400 | Mikrophon2 |
| 0xFFFFFFFF | nicht definiert |
TTESTSTATUS
Dimensions: 6 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00 | Test nicht gestartet |
| 0x01 | Test läuft |
| 0x02 | Test beendet ohne Fehler |
| 0x03 | Test beendet mit Fehlern |
| 0x04 | Test unterbrochen |
| 0xFF | Nicht definiert |
RES_0XA076
Dimensions: 1 rows × 13 columns
| RESULTNAME | STR | STPR | RRR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| STAT_ECALL | - | - | + | 0/1 | - | char | - | - | - | - | - | Status Notruf (Ecall); 0 = ECall deaktiviert 1 = ECall aktiviert |
ARG_0XA076
Dimensions: 1 rows × 14 columns
| ARG | STR | STPR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ARG_ECALL | + | - | 0/1 | - | char | - | - | - | - | - | 0.0 | - | Notruf (Ecall); 0 = ECall deaktivieren 1 = ECall aktivieren |
RES_0XA079
Dimensions: 1 rows × 13 columns
| RESULTNAME | STR | STPR | RRR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| STAT_RESET_TO_DEFAULT_CONFIG | - | - | + | 0-n | - | unsigned char | - | TResetStatus | - | - | - | Status Reset Werte gemäß Tabelle TResetStatus 0 UNKNOWN - unbekannt 1 ACTIVE - läuft noch 2 SUCCESS - alles OK 3 FAILED - mit Fehler beendet 4 IDLE - wurde nicht gestartet |
TRESETSTATUS
Dimensions: 6 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00 | unbekannt |
| 0x01 | läuft noch |
| 0x02 | alles OK |
| 0x03 | mit Fehler |
| 0x04 | wurde nicht gestartet |
| 0xFF | undefinierter Zustand |
RES_0XA07A
Dimensions: 3 rows × 13 columns
| RESULTNAME | STR | STPR | RRR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| STAT_PROVISIONING | - | - | + | 0-n | - | unsigned char | - | TProvisioningStatusEcall | - | - | - | Status des Provisionierungsprozess Werte gemäß Tabelle TProvisioningStatusEcall |
| STAT_ECALL_OTA_ID_WERT | - | - | + | - | - | string | - | - | - | - | - | Version von den aktuellen OTA Daten |
| STAT_ECALL_DAS_ID_WERT | - | - | + | - | - | string | - | - | - | - | - | Version von den aktuellen DAS Daten |
TPROVISIONINGSTATUSECALL
Dimensions: 6 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00 | unbekannt |
| 0x01 | läuft noch |
| 0x02 | alles OK |
| 0x03 | mit Fehler beendet |
| 0x04 | wurde nicht gestartet |
| 0xFF | nicht definiert |
ARG_0XA086
Dimensions: 3 rows × 14 columns
| ARG | STR | STPR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ARG_FREQUENZ | + | - | Hz | high | unsigned int | - | - | - | - | - | - | - | Frequenz in Hertz. Bereich 400 bis 3400 Hz. Sonst Request out of range |
| ARG_LAUTSTAERKE | + | - | - | high | unsigned char | - | - | - | - | - | - | - | Lautstaerke von 0-15. Minimal- und Maximalbereich eincodiert. Bei ungueltigen Einganben kommt Request out of range |
| ARG_DAUER | + | - | - | high | unsigned char | - | - | - | - | - | - | - | Dauer des Tons. Wertebereich von 0 bis 255 |
TPOWERSTATENEC
Dimensions: 12 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00 | Default; This state should never be logged |
| 0x01 | Sleepmode Power Off |
| 0x02 | Sleepmode Power On |
| 0x03 | Silent Operation |
| 0x04 | Normal Operation |
| 0x05 | Reset |
| 0x06 | Prepare Shutdown |
| 0x07 | High Temperature Shutdown |
| 0x0A | Wake up MB |
| 0x0B | Time Update1 |
| 0x0C | Time Update2 |
| 0xFF | Nicht definiert |
TPOWEREVENTNEC
Dimensions: 32 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00 | No change |
| 0x01 | Clamp R On |
| 0x02 | Active eCall |
| 0x03 | NAD Wake-Up |
| 0x04 | eCall Button |
| 0x05 | Airbag active |
| 0x06 | CAN on |
| 0x07 | First-Switch-To-Power |
| 0x08 | Wakeup Error |
| 0x09 | Wakeup Vehicle Request |
| 0x0A | Wakeup MB Request |
| 0x0B | NAD Always On expired |
| 0x0C | MAX RS activation reached |
| 0x0D | Network lost |
| 0x0E | High Power Timer expired |
| 0x15 | !Clamp R On && ! Active eCall On && !RST |
| 0x16 | Go to Sleep Power On |
| 0x17 | Go to Sleep Power Off |
| 0x18 | Go to Sleep Power Diagnostic |
| 0x19 | Over Temperature detected |
| 0x1A | NAD Off |
| 0x1E | NAD error |
| 0x1F | Request by Coding; Diagnostic reset |
| 0x20 | Wakeup by eCall; Only during shutdown sequence |
| 0x21 | Wakeup by NAD; Only during shutdown sequence |
| 0x22 | Wakeup by Clamp R On; Only during shutdown sequence |
| 0x23 | Wakeup by Can; Only during shutdown sequence |
| 0x24 | Wakeup by Airbag Crash; Only during shutdown sequence |
| 0x25 | Wakeup by Airbag; Only during shutdown sequence |
| 0x26 | Watchdog |
| 0x27 | Over Temperature Timer expired |
| 0xFF | Nicht definiert |
TPOWERSTATENAD
Dimensions: 13 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00 | Default; This state should never be logged |
| 0x01 | Sleep Power Off |
| 0x02 | Nad Always On |
| 0x03 | Normal Operation |
| 0x04 | Active ECall |
| 0x05 | Wakeup Nec |
| 0x06 | Wakeup Main Bord |
| 0x0B | Wakeup Vehicle |
| 0x0C | Time Update 1 |
| 0x0D | Time Update 2 |
| 0x0E | Main Bord Active |
| 0x0F | Main Bord Inactive |
| 0xFF | Nicht definiert |
TPOWEREVENTNAD
Dimensions: 12 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00 | No Change |
| 0x01 | Main Bord Active |
| 0x02 | Main Bord Inactive |
| 0x03 | Active ECall |
| 0x04 | NAD Always On Expired |
| 0x05 | RST |
| 0x06 | Wakeup Vehicle Request |
| 0x07 | Max RS Activation |
| 0x08 | Network Lost |
| 0x09 | Wakeup By Nec |
| 0x0A | Temperature Threshold |
| 0xFF | Nicht definiert |
TSTATEECALLLOG
Dimensions: 33 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x0000 | DEFAULT |
| 0x0A00 | RELEASE_CALL_NORMAL |
| 0x0A01 | RELEASE_CALL_HANGUP |
| 0x0A02 | RELEASE_CALL_DROPPED |
| 0x0A03 | RELEASE_CALL_CANCELLED |
| 0x0B00 | OPERATION_RESULT_UNDEFINED |
| 0x0B01 | OPERATION_RESULT_DISABLED |
| 0x0B02 | OPERATION_RESULT_FAILED |
| 0x0B03 | OPERATION_RESULT_SUCCESS |
| 0x0C00 | OPERATION_RESULT_UNDEFINED |
| 0x0C01 | OPERATION_RESULT_DISABLED |
| 0x0C02 | OPERATION_RESULT_FAILED |
| 0x0C03 | OPERATION_RESULT_SUCCESS |
| 0x0D00 | OPERATION_RESULT_UNDEFINED |
| 0x0D01 | OPERATION_RESULT_DISABLED |
| 0x0D02 | OPERATION_RESULT_FAILED |
| 0x0D03 | OPERATION_RESULT_SUCCESS |
| 0x0E00 | UNDEFINED |
| 0x0E01 | ASSIST_MANUAL |
| 0x0E02 | ASSIST_AUTOMATIC |
| 0x0E03 | PSAP_VOICE_MANUAL |
| 0x0E04 | PSAP_VOICE_AUTOMATIC |
| 0x0E05 | ASSIST_AUTOMAIC_FAILED_PSAP_ACTIVATED |
| 0x0E06 | ASSIST_MANUAL_FAILED_PSAP_ACTIVATED |
| 0x1100 | FAILED |
| 0x1101 | SUCCESSFUL |
| 0x1200 | ECALL_BROADER_SHUTTER |
| 0x1201 | ECALL_MOST_MESSAGE |
| 0x1202 | ECALL_EMERGENCY_BUTTON |
| 0x1203 | ECALL_AUTOMATIC |
| 0x1204 | ECALL_EXTERNAL_TRIGGERS |
| 0x1205 | ECALL_TRIGGER_SOURCE_UNDEFINED |
| 0xFFFF | Nicht definiert |
TEVENTECALLLOG
Dimensions: 36 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00 | DEFAULT |
| 0x01 | TIME_UPDATE_1 |
| 0x02 | TIME_UPDATE_2 |
| 0x03 | MILAGE_1 |
| 0x04 | MILAGE_2 |
| 0x05 | MILAGE_3 |
| 0x06 | MILAGE_4 |
| 0x0A | VOICE_CALL_RELEASE_STATE |
| 0x0B | SEND_BACKUP_SMS_RESULT |
| 0x0C | SEND_MAIN_SMS_RESULT |
| 0x0D | SEND_SECOND_BACKUP_SMS_RESULT |
| 0x0E | TYPE |
| 0x0F | DIAL_ATTEMPT |
| 0x10 | SMS_ATTEMPT |
| 0x11 | ECALL_RESULT |
| 0x12 | TRIGGER_SOURCE |
| 0x14 | TIME_BACKUP_SMS_SENT |
| 0x15 | TIME_DIAL |
| 0x16 | TIME_SEND_MAIN_SMS |
| 0x17 | TIME_SEND_DTMF |
| 0x18 | TIME_PREPARE_FOR_TERMINATE_EVENT_RECEIVED |
| 0x19 | TIME_TERMINATE_EVENT_RECEIVED |
| 0x1A | TIME_VOICE_CALL_RELEASE |
| 0x1B | TIME_SEND_SECOND_BACKUP_SMS |
| 0x1C | TIME_ECALL_FINISHED |
| 0x1D | TIME_ECALL_REOPENED_BY_OPERATOR_CALL_BACK |
| 0x1E | TIME_ECALL_REOPENED_BY_REQUEST_UPDATE |
| 0x1F | TIME_CALLBACK_MODE_ENDED |
| 0x20 | TIME_MFL_HANGUP_RECEIVED |
| 0x21 | TIME_ECALL_CANCELLED |
| 0x22 | TIME_POSITION_UPDATE_RECEIVED0 |
| 0x23 | TIME_POSITION_UPDATE_RECEIVED1 |
| 0x24 | TIME_POSITION_UPDATE_RECEIVED2 |
| 0x25 | TIME_POSITION_UPDATE_RECEIVED3 |
| 0x26 | TIME_POSITION_UPDATE_RECEIVED4 |
| 0xFF | Nicht definiert |