Skip to content

eme_04_alt.prg

INFO

Field Value
ECU Elektrische Maschine Elektronik Hybrid Gen. 1.5
ORIGIN BMW EA-412 Roland_Koeppl
REVISION 1.001
AUTHOR CAS DHS-F Joerg_Scheiner, CAS DHS-F Sven_Kasner, BMW EA-412 Jos
COMMENT I410
PACKAGE 1.11
SPRACHE deutsch

Jobs

Index

  • INFO - Information SGBD
  • INITIALISIERUNG - Initialisierung und Kommunikationsparameter
  • IDENT - Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
  • FS_LESEN - Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
  • FS_LESEN_DETAIL - Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
  • FS_LOESCHEN - Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
  • PRUEFSTEMPEL_LESEN - Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
  • PRUEFSTEMPEL_SCHREIBEN - Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
  • SVK_LESEN - Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
  • STATUS_LESEN - Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
  • STEUERN - Vorgeben eines Status UDS : $2E WriteDataByIdentifier
  • SERIENNUMMER_LESEN - Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
  • STEUERN_ROUTINE - Vorgeben eines Status UDS : $31 RoutineControl
  • FS_SPERREN - Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
  • HERSTELLINFO_LESEN - Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
  • DIAGNOSE_AUFRECHT - Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
  • DIAGNOSE_MODE - SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
  • ENERGIESPARMODE - Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
  • STATUS_ENERGIESPARMODE - Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
  • STATUS_BETRIEBSMODE - Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default
  • STEUERN_BETRIEBSMODE - Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default
  • STEUERGERAETE_RESET - Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
  • STEUERN_ROE_STOP - Temporaeres Deaktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $00 Stop $02 (EventWindowTime)
  • STATUS_ROE_REPORT - Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $04 report activated events
  • STEUERN_ROE_START - Temporaeres Aktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $05 Start $02 (EventWindowTime)
  • STEUERN_ROE_PERSISTENT_STOP - Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime)
  • STEUERN_ROE_PERSISTENT_START - Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime)
  • DIAG_SESSION_LESEN - Aktive Diagnose-Session auslesen UDS : $22 ReadDataByIdentifier UDS : $F186 ActiveDiagnosticSession Modus: Default
  • FLASH_TP_LESEN - Flash Timing Parameter auslesen UDS : $22 ReadDataByIdentifier UDS : $2504 FlashTimingParameter Modus: Default
  • PROG_ZAEHLER_LESEN - Programmierzaehler lesen UDS : $22 ReadDataByIdentifier UDS : $2502 ProgrammingCounter Modus: Default
  • PROG_MAX_LESEN - Anzahl der maximal möglichen Programmiervorgänge auslesen UDS : $22 ReadDataByIdentifier UDS : $2503 ProgrammingCounter Modus: Default

INFO

Information SGBD

No arguments.

Results

Name Type Comment
ECU string Steuergerät im Klartext
ORIGIN string Steuergeräte-Verantwortlicher
REVISION string Versions-Nummer
AUTHOR string Namen aller Autoren
COMMENT string wichtige Hinweise
PACKAGE string Include-Paket-Nummer
SPRACHE string deutsch, english

INITIALISIERUNG

Initialisierung und Kommunikationsparameter

No arguments.

Results

Name Type Comment
DONE int 1, wenn Okay

IDENT

Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default

No arguments.

Results

Name Type Comment
ID_SG_ADR long Steuergeraeteadresse
ID_SGBD_INDEX long Index zur Erkennung der SG-Variante
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

FS_LESEN

Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default

No arguments.

Results

Name Type Comment
F_VERSION int Typ des Fehlerspeichers Fuer UDS immer 3
F_HEX_CODE binary Fehlerdaten pro Fehler als Hexcode
F_ORT_NR long Index fuer Fehlerort
F_ORT_TEXT string Fehlerort als Text table FOrtTexte ORTTEXT
F_EREIGNIS_DTC int 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC
F_READY_NR int Readyness Flag (Standard-Fehlerart) als Zahl
F_READY_TEXT string Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
F_VORHANDEN_NR int Fehler vorhanden (Standard-Fehlerart) als Zahl
F_VORHANDEN_TEXT string Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
F_WARNUNG_NR int Warnlampen Flag (Standard-Fehlerart) als Zahl
F_WARNUNG_TEXT string Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

FS_LESEN_DETAIL

Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default

Arguments

Name Type Comment
F_CODE long gewaehlter Fehlercode

Results

Name Type Comment
F_VERSION int Typ des Fehlerspeichers Fuer UDS immer 3
F_HEX_CODE binary Fehlerdaten pro Fehler als Hexcode
F_ORT_NR long Index fuer Fehlerort
F_ORT_TEXT string Fehlerort als Text table FOrtTexte ORTTEXT
F_EREIGNIS_DTC int 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC
F_READY_NR int Readyness Flag (Standard-Fehlerart) als Zahl
F_READY_TEXT string Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
F_VORHANDEN_NR int Fehler vorhanden (Standard-Fehlerart) als Zahl
F_VORHANDEN_TEXT string Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
F_WARNUNG_NR int Warnlampen Flag (Standard-Fehlerart) als Zahl
F_WARNUNG_TEXT string Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT
F_HFK int Haufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf
F_HLZ int Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Haufigkeitszaehler
F_UEBERLAUF int 0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers
F_FEHLERKLASSE_NR int 0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich !
F_FEHLERKLASSE_TEXT string Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT
F_UW_ANZ int Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung
F_UW_KM long Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht
F_UW_ZEIT long Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht
F_SAE_CODE unsigned int Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD
F_SAE_CODE_STRING string 5 stelliger Text in der Form 'Sxxxx'
F_SAE_CODE_TEXT string Text zu F_SAE_CODE
_RESPONSE_SNAPSHOT binary Hex-Antwort von SG
_RESPONSE_EXTENDED_DATA binary Hex-Antwort von SG
_RESPONSE_SEVERITY binary Hex-Antwort von SG
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT

FS_LOESCHEN

Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default

Arguments

Name Type Comment
F_CODE long 0x??????: Angabe eines einzelnen Fehlers Default: 0xFFFFFF: alle Fehler

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

PRUEFSTEMPEL_LESEN

Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default

No arguments.

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
BYTE1 int Bereich: 0-255 bzw. 0x00-0xFF
BYTE2 int Bereich: 0-255 bzw. 0x00-0xFF
BYTE3 int Bereich: 0-255 bzw. 0x00-0xFF
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

PRUEFSTEMPEL_SCHREIBEN

Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default

Arguments

Name Type Comment
BYTE1 int Bereich: 0-255 bzw. 0x00-0xFF
BYTE2 int Bereich: 0-255 bzw. 0x00-0xFF
BYTE3 int Bereich: 0-255 bzw. 0x00-0xFF

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

SVK_LESEN

Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default

Arguments

Name Type Comment
SVK string table SVK_ID BEZEICHNUNG WERT default SVK_AKTUELL

Results

Name Type Comment
PROG_TEST int Programmierabhaengigkeiten (ProgrammingDependenciesChecked) 1: IO : Signaturpruefung und ProgrammingDependenciesCheck erfolgreich 2: NIO: mindestens eine SWE fehlerhaft oder ProgrammingDependenciesCheck nicht durchgefuehrt 3: NIO: mindestens eine SWE passt nicht mit einer HWE zusammen 4: NIO: mindestens eine SWE passt nicht mit einer anderen SWE zusammen sonst: reserviert
ANZAHL_EINHEITEN int Anzahl der xWEn
PROG_DATUM string Programmierdatum (DD.MM.YY)
PROG_KM long KM-Stand bei Programmierung (10 KM bis 655350 KM) Inkrement sind 10 KM -1: KM-Stand wird nicht unterstuetzt
PROZESSKLASSE_WERT int table Prozessklassen WERT dezimale Angabe der Prozessklasse
PROZESSKLASSE_TEXT string table Prozessklassen BEZEICHNUNG Text-Angabe der Prozessklasse
PROZESSKLASSE_KURZTEXT string table Prozessklassen PROZESSKLASSE Text-Angabe des Prozessklassenkurztextes
SGBM_IDENTIFIER string Angabe SGBM-ID der Prozessklasse
VERSION string Angabe der Version der Prozessklasse
SGBM_ID string Angabe von Prozessklasse, SGBM-Identifier, Version
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STATUS_LESEN

Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier

Arguments

Name Type Comment
ARGUMENT_SPALTE string 'ARG', 'ID', 'LABEL'
STATUS string Es muss mindestens ein Argument übergeben werden Es wird das zugehörige result erzeugt table SG_Funktionen ARG ID RESULTNAME RES_TABELLE ARG_TABELLE

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Antwort von SG
_RESPONSE binary Hex-Antwort von SG

STEUERN

Vorgeben eines Status UDS : $2E WriteDataByIdentifier

Arguments

Name Type Comment
ARGUMENT_SPALTE string 'ARG', 'ID', 'LABEL'
STATUS string Siehe table SG_Funktionen ARG ID LABEL ARG_TABELLE
WERT string Es muss mindestens ein Argument übergeben werden Argumente siehe table SG_Funktionen ARG ID ARG_TABELLE

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Antwort von SG
_RESPONSE binary Hex-Antwort von SG

SERIENNUMMER_LESEN

Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default

No arguments.

Results

Name Type Comment
SERIENNUMMER string Seriennummer des Steuergeraets
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STEUERN_ROUTINE

Vorgeben eines Status UDS : $31 RoutineControl

Arguments

Name Type Comment
ARGUMENT_SPALTE string 'ARG', 'ID', 'LABEL'
STATUS string Siehe table SG_Funktionen ARG ID RES_TABELLE ARG_TABELLE
STEUERPARAMETER string 'STR' = startRoutine 'STPR' = stopRoutine 'RRR' = requestRoutineResults
WERT string Argumente siehe table SG_Funktionen ARG_TABELLE

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Antwort von SG
_RESPONSE binary Hex-Antwort von SG

FS_SPERREN

Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default

Arguments

Name Type Comment
SPERREN string "ja" -> Fehlerspeicher sperren "nein" -> Fehlerspeicher freigeben table DigitalArgument TEXT Default: "ja"

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

HERSTELLINFO_LESEN

Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default

No arguments.

Results

Name Type Comment
ID_LIEF_NR long Lieferantennummer 0xFFFFFF, falls nicht vorhanden
ID_LIEF_TEXT string Text zu ID_LIEF_NR table Lieferanten LIEF_TEXT unbekannter Hersteller, falls nicht vorhanden
ID_DATUM string Herstelldatum (DD.MM.YY)
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG
_REQUEST_2 binary Hex-Auftrag an SG
_RESPONSE_2 binary Hex-Antwort von SG

DIAGNOSE_AUFRECHT

Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default

Arguments

Name Type Comment
SG_ANTWORT string "ja" -> SG soll antworten "nein" -> SG soll nicht antworten table DigitalArgument TEXT Default: SG soll antworten

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

DIAGNOSE_MODE

SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job

Arguments

Name Type Comment
MODE string gewuenschter Diagnose-Modus table DiagMode MODE MODE_TEXT Defaultwert: DEFAULT (DefaultMode)

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

ENERGIESPARMODE

Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default

Arguments

Name Type Comment
MODE int 0x00: Normalmode 0x01: Fertigungsmode 0x02: Transportmode 0x03: Flashmode

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STATUS_ENERGIESPARMODE

Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default

No arguments.

Results

Name Type Comment
STAT_ENERGIESPARMODE_WERT int Ausgabe des Energiesparmodes 0: Kein Energiesparmode gesetzt 1: Produktionsmode gesetzt 2: Transportmode gesetzt 3: Flashmode gesetzt -1: Mode ungueltig
STAT_ENERGIESPARMODE_TEXT string Text zu STAT_ENERGIESPARMODE_WERT
STAT_PRODUKTIONSMODE_EIN int 0: Produktionsmode nicht aktiv 1: Produktionsmode aktiv
STAT_TRANSPORTMODE_EIN int 0: Transportmode nicht aktiv 1: Transportmode aktiv
STAT_FLASHMODE_EIN int 0: Flashmode nicht aktiv 1: Flashmode aktiv
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STATUS_BETRIEBSMODE

Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default

No arguments.

Results

Name Type Comment
STAT_BETRIEBSMODE_WERT int Aktueller Betriebsmode table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle)
STAT_BETRIEBSMODE_TEXT string Textausgabe STAT_BETRIEBSMODE_WERT table Betriebsmode TEXT
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STEUERN_BETRIEBSMODE

Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default

Arguments

Name Type Comment
BETRIEBSMODE int Betriebsmode setzen table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle)

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STEUERGERAETE_RESET

Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default

No arguments.

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STEUERN_ROE_STOP

Temporaeres Deaktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $00 Stop $02 (EventWindowTime)

No arguments.

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STATUS_ROE_REPORT

Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $04 report activated events

No arguments.

Results

Name Type Comment
STAT_ROE_AKTIV char 0x00 = Aktive Fehlermeldung deaktiviert 0x01 = Aktive Fehlermeldung aktiviert 0xFF = Status der aktiven Fehlermeldung nicht feststellbar
STAT_ROE_AKTIV_TEXT string Interpretation von STAT_ROE_AKTIV table UDS_TAB_ROE_AKTIV TEXT
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STEUERN_ROE_START

Temporaeres Aktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $05 Start $02 (EventWindowTime)

No arguments.

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STEUERN_ROE_PERSISTENT_STOP

Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime)

No arguments.

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

STEUERN_ROE_PERSISTENT_START

Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime)

No arguments.

Results

Name Type Comment
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

DIAG_SESSION_LESEN

Aktive Diagnose-Session auslesen UDS : $22 ReadDataByIdentifier UDS : $F186 ActiveDiagnosticSession Modus: Default

No arguments.

Results

Name Type Comment
DIAG_SESSION_WERT int Diagnose-Session (1 Byte)
DIAG_SESSION_TEXT string Diagnose-Session als Text
DIAG_DETAIL_WERT int Details zur Diagnose-Session (1 Byte)
DIAG_DETAIL_TEXT string Details zur Diagnose-Session als Text
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

FLASH_TP_LESEN

Flash Timing Parameter auslesen UDS : $22 ReadDataByIdentifier UDS : $2504 FlashTimingParameter Modus: Default

No arguments.

Results

Name Type Comment
FLASH_LOESCHEN int EraseMemoryTime (2 Byte)
FLASH_TEST int CheckMemoryTime (2 Byte)
FLASH_BOOT int BootloaderInstallationTime (2 Byte)
FLASH_AUTHENT int AuthenticationTime (2 Byte)
FLASH_RESET int ResetTime (2 Byte)
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

PROG_ZAEHLER_LESEN

Programmierzaehler lesen UDS : $22 ReadDataByIdentifier UDS : $2502 ProgrammingCounter Modus: Default

No arguments.

Results

Name Type Comment
PROG_ZAEHLER_STATUS_WERT int Status, wie oft das SG programmierbar ist
PROG_ZAEHLER_STATUS_TEXT string Status, wie oft das SG programmierbar ist
PROG_ZAEHLER int Programmierzaehler
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

PROG_MAX_LESEN

Anzahl der maximal möglichen Programmiervorgänge auslesen UDS : $22 ReadDataByIdentifier UDS : $2503 ProgrammingCounter Modus: Default

No arguments.

Results

Name Type Comment
PROG_MAX long maximal mögliche Programmiervorgänge Sonderfall 0xFFFF: Anzahl der Programmiervorgänge unbegrenzt
JOB_STATUS string OKAY, wenn fehlerfrei table JobResult STATUS_TEXT
_REQUEST binary Hex-Auftrag an SG
_RESPONSE binary Hex-Antwort von SG

Tables

Index

JOBRESULT

Dimensions: 66 rows × 2 columns

SB STATUS_TEXT
0x10 ERROR_ECU_GENERAL_REJECT
0x11 ERROR_ECU_SERVICE_NOT_SUPPORTED
0x12 ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED
0x13 ERROR_ECU_INCORRECT_MESSAGE_LENGTH_OR_INVALID_FORMAT
0x14 ERROR_ECU_RESPONSE_TOO_LONG
0x21 ERROR_ECU_BUSY_REPEAT_REQUEST
0x22 ERROR_ECU_CONDITIONS_NOT_CORRECT
0x24 ERROR_ECU_REQUEST_SEQUENCE_ERROR
0x25 ERROR_ECU_NO_RESPONSE_FROM_SUBNET_COMPONENT
0x26 ERROR_ECU_FAILURE_PREVENTS_EXECUTION_OF_REQUESTED_ACTION
0x31 ERROR_ECU_REQUEST_OUT_OF_RANGE
0x33 ERROR_ECU_SECURITY_ACCESS_DENIED
0x35 ERROR_ECU_INVALID_KEY
0x36 ERROR_ECU_EXCEED_NUMBER_OF_ATTEMPTS
0x37 ERROR_ECU_REQUIRED_TIME_DELAY_NOT_EXPIRED
0x70 ERROR_ECU_UPLOAD_DOWNLOAD_NOT_ACCEPTED
0x71 ERROR_ECU_TRANSFER_DATA_SUSPENDED
0x72 ERROR_ECU_GENERAL_PROGRAMMING_FAILURE
0x73 ERROR_ECU_WRONG_BLOCK_SEQUENCE_COUNTER
0x78 ERROR_ECU_REQUEST_CORRECTLY_RECEIVED__RESPONSE_PENDING
0x7E ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED_IN_ACTIVE_SESSION
0x7F ERROR_ECU_SERVICE_NOT_SUPPORTED_IN_ACTIVE_SESSION
0x81 ERROR_ECU_RPM_TOO_HIGH
0x82 ERROR_ECU_RPM_TOO_LOW
0x83 ERROR_ECU_ENGINE_IS_RUNNING
0x84 ERROR_ECU_ENGINE_IS_NOT_RUNNING
0x85 ERROR_ECU_ENGINE_RUN_TIME_TOO_LOW
0x86 ERROR_ECU_TEMPERATURE_TOO_HIGH
0x87 ERROR_ECU_TEMPERATURE_TOO_LOW
0x88 ERROR_ECU_VEHICLE_SPEED_TOO_HIGH
0x89 ERROR_ECU_VEHICLE_SPEED_TOO_LOW
0x8A ERROR_ECU_THROTTLE_PEDAL_TOO_HIGH
0x8B ERROR_ECU_THROTTLE_PEDAL_TOO_LOW
0x8C ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_NEUTRAL
0x8D ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_GEAR
0x8F ERROR_ECU_BRAKE_SWITCH_NOT_CLOSED
0x90 ERROR_ECU_SHIFTER_LEVER_NOT_IN_PARK
0x91 ERROR_ECU_TORQUE_CONVERTER_CLUTCH_LOCKED
0x92 ERROR_ECU_VOLTAGE_TOO_HIGH
0x93 ERROR_ECU_VOLTAGE_TOO_LOW
?00? OKAY
?01? ERROR_ECU_NO_RESPONSE
?02? ERROR_ECU_INCORRECT_LEN
?03? ERROR_ECU_INCORRECT_RESPONSE_ID
?04? ERROR_ECU_TA_RESPONSE_NOT_SA_REQUEST
?05? ERROR_ECU_SA_RESPONSE_NOT_TA_REQUEST
?06? ERROR_ECU_RESPONSE_INCORRECT_DATA_IDENTIFIER
?07? ERROR_ECU_RESPONSE_TOO_MUCH_DATA
?08? ERROR_ECU_RESPONSE_TOO_LESS_DATA
?09? ERROR_ECU_RESPONSE_VALUE_OUT_OF_RANGE
?0A? ERROR_TABLE
?10? ERROR_F_CODE
?12? ERROR_INTERPRETATION
?13? ERROR_F_POS
?14? ERROR_ECU_RESPONSE_INCORRECT_IO_CONTROL_PARAMETER
?15? ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_CONTROL_TYPE
?16? ERROR_ECU_RESPONSE_INCORRECT_SUB_FUNCTION
?17? ERROR_ECU_RESPONSE_INCORRECT_DYNAMICALLY_DEFINED_DATA_IDENTIFIER
?18? ERROR_ECU_RESPONSE_NO_STRING_END_CHAR
?50? ERROR_BYTE1
?51? ERROR_BYTE2
?52? ERROR_BYTE3
?80? ERROR_SVK_INCORRECT_LEN
?81? ERROR_SVK_INCORRECT_FINGERPRINT
?F0? ERROR_ARGUMENT
0xXY ERROR_ECU_UNKNOWN_NEGATIVE_RESPONSE

LIEFERANTEN

Dimensions: 115 rows × 2 columns

LIEF_NR LIEF_TEXT
0x000001 Reinshagen => Delphi
0x000002 Kostal
0x000003 Hella
0x000004 Siemens
0x000005 Eaton
0x000006 UTA
0x000007 Helbako
0x000008 Bosch
0x000009 Loewe => Lear
0x000010 VDO
0x000011 Valeo
0x000012 MBB
0x000013 Kammerer
0x000014 SWF
0x000015 Blaupunkt
0x000016 Philips
0x000017 Alpine
0x000018 Continental Teves
0x000019 Elektromatik Suedafrika
0x000020 Becker
0x000021 Preh
0x000022 Alps
0x000023 Motorola
0x000024 Temic
0x000025 Webasto
0x000026 MotoMeter
0x000027 Delphi PHI
0x000028 DODUCO => BERU
0x000029 DENSO
0x000030 NEC
0x000031 DASA
0x000032 Pioneer
0x000033 Jatco
0x000034 Fuba
0x000035 UK-NSI
0x000036 AABG
0x000037 Dunlop
0x000038 Sachs
0x000039 ITT
0x000040 FTE
0x000041 Megamos
0x000042 TRW
0x000043 Wabco
0x000044 ISAD Electronic Systems
0x000045 HEC (Hella Electronics Corporation)
0x000046 Gemel
0x000047 ZF
0x000048 GMPT
0x000049 Harman Kardon
0x000050 Remes
0x000051 ZF Lenksysteme
0x000052 Magneti Marelli
0x000053 Borg Instruments
0x000054 GETRAG
0x000055 BHTC (Behr Hella Thermocontrol)
0x000056 Siemens VDO Automotive
0x000057 Visteon
0x000058 Autoliv
0x000059 Haberl
0x000060 Magna Steyr
0x000061 Marquardt
0x000062 AB-Elektronik
0x000063 Siemens VDO Borg
0x000064 Hirschmann Electronics
0x000065 Hoerbiger Electronics
0x000066 Thyssen Krupp Automotive Mechatronics
0x000067 Gentex GmbH
0x000068 Atena GmbH
0x000069 Magna-Donelly
0x000070 Koyo Steering Europe
0x000071 NSI B.V
0x000072 AISIN AW CO.LTD
0x000073 Shorlock
0x000074 Schrader
0x000075 BERU Electronics GmbH
0x000076 CEL
0x000077 Audio Mobil
0x000078 rd electronic
0x000079 iSYS RTS GmbH
0x000080 Westfalia Automotive GmbH
0x000081 Tyco Electronics
0x000082 Paragon AG
0x000083 IEE S.A
0x000084 TEMIC AUTOMOTIVE of NA
0x000085 AKsys GmbH
0x000086 META System
0x000087 Hülsbeck & Fürst GmbH & Co KG
0x000088 Mann & Hummel Automotive GmbH
0x000089 Brose Fahrzeugteile GmbH & Co
0x000090 Keihin
0x000091 Vimercati S.p.A.
0x000092 CRH
0x000093 TPO Display Corp.
0x000094 KÜSTER Automotive Control
0x000095 Hitachi Automotive
0x000096 Continental Automotive
0x000097 TI-Automotive
0x000098 Hydro
0x000099 Johnson Controls
0x00009A Takata- Petri
0x00009B Mitsubishi Electric B.V. (Melco)
0x00009C Autokabel
0x00009D GKN-Driveline
0x00009E Zollner Elektronik AG
0x00009F PEIKER acustics GmbH
0x0000A0 Bosal-Oris
0x0000A1 Cobasys
0x0000A2 Lighting Reutlingen GmbH
0x0000A3 CONTI VDO
0x0000A4 ADC Automotive Distance Control Systems GmbH
0x0000A5 Funkwerk Dabendorf GmbH
0x0000A6 Lame
0x0000A7 Magna/Closures
0x0000A8 Wanyu
0xFFFFFF unbekannter Hersteller

FARTTEXTE

Dimensions: 18 rows × 2 columns

ARTNR ARTTEXT
0x00 keine Fehlerart verfügbar
0x04 Fehler momentan nicht vorhanden, aber bereits gespeichert
0x05 Fehler momentan vorhanden und bereits gespeichert
0x08 Fehler momentan nicht vorhanden, aber bereits gespeichert
0x09 Fehler momentan vorhanden und bereits gespeichert
0x0C Fehler momentan nicht vorhanden, aber bereits gespeichert
0x0D Fehler momentan vorhanden und bereits gespeichert
0x44 Fehler gespeichert
0x45 Fehler gespeichert
0x48 Fehler gespeichert
0x49 Fehler gespeichert
0x4C Fehler gespeichert
0x4D Fehler gespeichert
0x10 Testbedingungen erfüllt
0x11 Testbedingungen noch nicht erfüllt
0x80 Fehler würde kein Aufleuchten einer Warnlampe verursachen
0x81 Fehler würde das Aufleuchten einer Warnlampe verursachen
0xFF unbekannte Fehlerart

DIGITALARGUMENT

Dimensions: 17 rows × 2 columns

TEXT WERT
ein 1
aus 0
ja 1
nein 0
auf 1
ab 0
an 1
yes 1
no 0
on 1
off 0
up 1
down 0
true 1
false 0
1 1
0 0

PROZESSKLASSEN

Dimensions: 24 rows × 3 columns

WERT PROZESSKLASSE BEZEICHNUNG
0x00 - ungueltig
0x01 HWEL Hardware (Elektronik)
0x02 HWAP Hardwareauspraegung
0x03 HWFR Hardwarefarbe
0x05 CAFD Codierdaten
0x06 BTLD Bootloader
0x08 SWFL Software ECU Speicherimage
0x09 SWFF Flash File Software
0x0A SWPF Pruefsoftware
0x0B ONPS Onboard Programmiersystem
0x0F FAFP FA2FP
0x1A TLRT Temporaere Loeschroutine
0x1B TPRG Temporaere Programmierroutine
0x07 FLSL Flashloader Slave
0x0C IBAD Interaktive Betriebsanleitung Daten
0x10 FCFA Freischaltcode Fahrzeug-Auftrag
0x1C BLUP Bootloader-Update Applikation
0x1D FLUP Flashloader-Update Applikation
0xA0 ENTD Entertainment Daten
0xA1 NAVD Navigation Daten
0xA2 FCFN Freischaltcode Funktion
0xC0 SWUP Software-Update Package
0xC1 SWIP Index Software-Update Package
0xFF - ungueltig

SVK_ID

Dimensions: 65 rows × 2 columns

WERT BEZEICHNUNG
0x01 SVK_AKTUELL
0x02 SVK_SUPPLIER
0x03 SVK_WERK
0x04 SVK_BACKUP_01
0x05 SVK_BACKUP_02
0x06 SVK_BACKUP_03
0x07 SVK_BACKUP_04
0x08 SVK_BACKUP_05
0x09 SVK_BACKUP_06
0x0A SVK_BACKUP_07
0x0B SVK_BACKUP_08
0x0C SVK_BACKUP_09
0x0D SVK_BACKUP_10
0x0E SVK_BACKUP_11
0x0F SVK_BACKUP_12
0x10 SVK_BACKUP_13
0x11 SVK_BACKUP_14
0x12 SVK_BACKUP_15
0x13 SVK_BACKUP_16
0x14 SVK_BACKUP_17
0x15 SVK_BACKUP_18
0x16 SVK_BACKUP_19
0x17 SVK_BACKUP_20
0x18 SVK_BACKUP_21
0x19 SVK_BACKUP_22
0x1A SVK_BACKUP_23
0x1B SVK_BACKUP_24
0x1C SVK_BACKUP_25
0x1D SVK_BACKUP_26
0x1E SVK_BACKUP_27
0x1F SVK_BACKUP_28
0x20 SVK_BACKUP_29
0x21 SVK_BACKUP_30
0x22 SVK_BACKUP_31
0x23 SVK_BACKUP_32
0x24 SVK_BACKUP_33
0x25 SVK_BACKUP_34
0x26 SVK_BACKUP_35
0x27 SVK_BACKUP_36
0x28 SVK_BACKUP_37
0x29 SVK_BACKUP_38
0x2A SVK_BACKUP_39
0x2B SVK_BACKUP_40
0x2C SVK_BACKUP_41
0x2D SVK_BACKUP_42
0x2E SVK_BACKUP_43
0x2F SVK_BACKUP_44
0x30 SVK_BACKUP_45
0x31 SVK_BACKUP_46
0x32 SVK_BACKUP_47
0x33 SVK_BACKUP_48
0x34 SVK_BACKUP_49
0x35 SVK_BACKUP_50
0x36 SVK_BACKUP_51
0x37 SVK_BACKUP_52
0x38 SVK_BACKUP_53
0x39 SVK_BACKUP_54
0x3A SVK_BACKUP_55
0x3B SVK_BACKUP_56
0x3C SVK_BACKUP_57
0x3D SVK_BACKUP_58
0x3E SVK_BACKUP_59
0x3F SVK_BACKUP_60
0x40 SVK_BACKUP_61
0xXY ERROR_UNKNOWN

DTCEXTENDEDDATARECORDNUMBER

Dimensions: 5 rows × 3 columns

WERT TEXT ANZ_BYTE
0x00 ISO_RESERVED 0
0x01 CONDITION_BYTE 1
0x02 HFK 1
0x03 HLZ 1
0xFF RECORD_UNKNOWN 0

DTCSNAPSHOTIDENTIFIER

Dimensions: 5 rows × 9 columns

UWNR UWTEXT UW_EINH L/H UWTYP NAME MUL DIV ADD
0x1700 KM_STAND 0-n - 0xFFFFFF - 1 1 0.000000
0x1701 ABS_ZEIT 0-n - 0xFFFFFFFF - 1 1 0.000000
0x1702 SAE_CODE 0-n - 0xFFFFFF - 1 1 0.000000
0x1731 Fehlerklasse_DTC - - u char - 1 1 0.000000
0xFFFF IDENTIFIER_UNKNOWN - - 0xFFFFFF - 1 1 0.000000

FEHLERKLASSE

Dimensions: 5 rows × 2 columns

NR TEXT
0x00 Keine Fehlerklasse verfuegbar
0x01 Ueberpruefung bei naechstem Werkstattbesuch
0x02 Ueberpruefung bei naechstem Halt
0x04 Ueberpruefung sofort erforderlich !
0xFF unbekannte Fehlerklasse

DIAGMODE

Dimensions: 11 rows × 3 columns

NR MODE MODE_TEXT
0x00 UNGUELTIG DefaultMode
0x01 DEFAULT DefaultMode
0x02 ECUPM ECUProgrammingMode
0x03 ECUEXTDIAG ECUExtendedDiagnosticSession
0x04 ECUSSDS ECUSafetySystemDiagnosticSession
0x40 ECUEOL ECUEndOfLineSession
0x41 ECUCODE ECUCodingSession
0x42 ECUSWT ECUSwtSession
0x43 ECUHDD ECUHDDDownloadSession
0x4F ECUDEVELOP ECUDevelopmentSession
0xXY -- unbekannter Diagnose-Mode

UDS_TAB_ROE_AKTIV

Dimensions: 3 rows × 2 columns

NR TEXT
0x00 Aktive Fehlermeldung deaktiviert
0x01 Aktive Fehlermeldung aktiviert
0xFF Status der aktiven Fehlermeldung nicht feststellbar

JOBRESULTEXTENDED

Dimensions: 1 rows × 2 columns

SB STATUS_TEXT
0xXY ERROR_UNKNOWN

BETRIEBSMODE

Dimensions: 2 rows × 3 columns

WERT TEXT BEDEUTUNG
0x00 kein Betriebsmode gesetzt kein Betriebsmode
0xFF ungültiger Betriebsmode ungültig

FDETAILSTRUKTUR

Dimensions: 6 rows × 2 columns

NAME TYP
F_UWB_ERW ja
SAE_CODE ja
F_HLZ ja
F_SEVERITY nein
F_UWB_SATZ 2
F_HLZ_VIEW -

IORTTEXTE

Dimensions: 1 rows × 3 columns

ORT ORTTEXT EREIGNIS_DTC
0xFFFFFF unbekannter Fehlerort 0

IDETAILSTRUKTUR

Dimensions: 4 rows × 2 columns

NAME TYP
F_UWB_ERW nein
SAE_CODE nein
F_HLZ nein
F_SEVERITY nein

RES_06323

Dimensions: 34 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_NV_MSA_DCDC_WERT Ah - unsigned int - - 1 - 0 -
STAT_NV_MSA_EKK_WERT Ah - unsigned long - - 1 - 0 -
STAT_NV_ENTL_EKK_STD_WERT Ah - unsigned long - - 1 - 0 -
STAT_NV_ENTL_EKK15_WERT Ah - unsigned long - - 1 - 0 -
STAT_NV_ENTL_DCDC15_WERT Ah - unsigned long - - 1 - 0 -
STAT_NV_ENTL_EM1_WERT Ah - unsigned long - - 1 - 0 -
STAT_NV_ENTL_EKK_WERT Ah - unsigned long - - 1 - 0 -
STAT_NV_ENTL_DCDC_WERT Ah - unsigned long - - 1 - 0 -
STAT_NV_MSA_EM1_WERT Ah - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_NULL_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_1_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_2_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_3_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_4_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_5_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_6_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_7_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_8_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_9_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_10_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_11_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_12_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_13_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_14_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_15_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_16_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_17_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_18_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_19_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_20_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_21_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_22_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_23_WERT s - unsigned long - - 1 - 0 -
STAT_NV_UHVB_SB_24_WERT s - unsigned long - - 1 - 0 -

FORTTEXTE

Dimensions: 299 rows × 3 columns

ORT ORTTEXT EREIGNIS_DTC
0x021A00 Energiesparmode aktiv 0
0x02FF1A Dummy-DTC: Applikationsfehler zum Testen 0
0x21EE00 Interlock Leitung unterbrochen 0
0x21EE01 Interlock Leitung: Kurzschluss auf Versorgung 12V 0
0x21EE02 Interlock Leitung: Kurzschluss nach Masse 0
0x21EE04 EME, interner Fehler, CY320: 3,3V Referenz defekt 0
0x21EE05 EME, interner Fehler, CY320: 5V Referenz defekt 0
0x21EE06 Interlock Leitung: Allgemeiner Fehler 0
0x21EE07 Interlock Leitung: Durchführungsfehler 0
0x21EE08 Leistungselektronik Pulswechselrichter: Phase U unterbrochen 0
0x21EE09 Leistungselektronik Pulswechselrichter: Phase V unterbrochen 0
0x21EE0A Leistungselektronik Pulswechselrichter: Phase W unterbrochen 0
0x21EE10 EME, Klemme 50: Wert unplausibel 0
0x21EE13 EME, interner Fehler, DC/DC: Wandler dauerhaft gesperrt 0
0x21EE14 Fehler in der einstellbaren Phasenzuordnung 0
0x21EE18 EME, interner Fehler: ROM-Initialisierung fehlgeschlagen 0
0x21EE19 EME, interner Fehler: ROM-Fehler im Betrieb 0
0x21EE1A EME, interner Fehler: RAM-Initialisierung fehlgeschlagen 0
0x21EE1B EME, interner Fehler: RAM-Fehler im Betrieb 0
0x21EE1C EME, interner Fehler: EEPROM defekt 0
0x21EE1D EME, interner Fehler: CPLD defekt (Registerinhalt falsch) 0
0x21EE20 EME, interner Fehler A/D-Wandler: Spannungswert gegenüber der Referenz des CY320 unplausibel 0
0x21EE21 EME, interner Fehler A/D-Wandlervergleich: Stromwert der Phase U zu hoch 0
0x21EE23 EME, interner Fehler A/D-Wandlervergleich: Stromwert der Phase V zu hoch 0
0x21EE25 EME, interner Fehler A/D-Wandlervergleich: Sinuswert des Rotorlagesensors zu hoch 0
0x21EE27 EME, interner Fehler A/D-Wandlervergleich: Cosinuswert des Rotorlagesensors zu hoch 0
0x21EE29 EME, interner Fehler Ebene 3 A/D-Wandler Strom Phase U: Spannungswert gegenüber der Referenz des CY320 unplausibel 0
0x21EE2A EME, interner Fehler Ebene 3 A/D-Wandler Strom Phase V: Spannungswert gegenüber der Referenz des CY320 unplausibel 0
0x21EE2B EME, interner Fehler Ebene 3 A/D-Wandler Position Sinus: Spannungswert gegenüber der Referenz des CY320 unplausibel 0
0x21EE2C EME, interner Fehler, CPLD: Taktgeber defekt 0
0x21EE2D EME, interner Fehler Ebene 3 A/D-Wandler Position Cosinus: Spannungswert gegenüber der Referenz des CY320 unplausibel 0
0x21EE2E EME, interner Fehler, E-Maschinenregelung, Parametersatz: Daten fehlerhaft (ZFS) 0
0x21EE2F EME, interner Fehler, E-Maschinenregelung, Parametersatz: Daten fehlerhaft (CAS) 0
0x21EE30 EME, Versorgungsspannung: Spannung zu hoch / interner Sensor defekt 0
0x21EE31 EME, redundante Versorgungsspannung: Spannung zu hoch / interner Sensor defekt 0
0x21EE32 EME, Versorgungsspannung: Spannung zu niedrig / interner Sensor defekt / Masseanschluss fehlt 0
0x21EE33 EME, redundante Versorgungsspannung: Spannung zu niedrig / interner Sensor defekt / Masseanschluss fehlt 0
0x21EE34 EME, Software: Inkompatible Softwareversion programmiert 0
0x21EE35 EME, interner Fehler: HW-Identifikation aus EEPROM nicht lesbar 0
0x21EE36 EME, interner Fehler, DC/DC-Wandler, Leistungshalbleiter Tiefsetzsteller: Transistor defekt oder Leitungsschluss 0
0x21EE37 EME, interner Fehler, DC/DC-Wandler, Leistungshalbleiter Hochsetzsteller: Transistor defekt oder Leitungsschluss 0
0x21EE38 EME, interner Fehler, DC/DC-Wandler, Leistungshalbleiter: Spannungsversorgung defekt 0
0x21EE39 EME, interner Fehler, DC/DC-Wandler, Leistungshalbleiter: HW-Initialisierungsfehler Versorgungsspannung 0
0x21EE3A EME, interner Fehler, DC/DC-Wandler, Messelektronik: HW-Initialisierungsfehler Versorgungsspannung 0
0x21EE3B EME, interner Fehler, DC/DC-Wandler: HW-Initialisierungsfehler Analogkomperator 0
0x21EE3C EME, interner Fehler, DC/DC-Wandler, Temperatursensor: Wert unplausibel 0
0x21EE3D EME, interner Fehler, DC/DC-Wandler, Temperatursensor: Hardware defekt (Temperatur über Messbereich) 0
0x21EE3E EME, interner Fehler, DC/DC-Wandler, Temperatursensor, Wertebereichsüberschreitung: Obere Schwelle 0
0x21EE3F EME, interner Fehler, DC/DC-Wandler: Taktgenerator defekt 0
0x21EE40 EME, interner Fehler, DC/DC-Wandler: Watchdog defekt 0
0x21EE41 EME, interner Fehler, DC/DC-Wandler: Fehler bei Initialisierung Tiefsetzstellerbetrieb 0
0x21EE42 EME, interner Fehler, DC/DC-Wandler: Fehler bei Initialisierung Hochsetzstellerbetrieb 0
0x21EE43 EME, interner Fehler, DC/DC-Wandler, Phasenmodulation: ungültige Parameter 0
0x21EE44 EME, interner Fehler, DC/DC-Wandler, Phasenmodulation: Notaus 0
0x21EE45 EME, interner Fehler, DC/DC-Wandler, Phasenmodulation: Treiberausgang 0
0x21EE46 EME, interner Fehler, DC/DC-Wandler, Phasenmodulation: PWM-Signal ungültig 0
0x21EE47 EME, interner Fehler, DC/DC-Wandler, Phasenmodulation: Watchdog-Fehler 0
0x21EE48 EME, interner Fehler, DC/DC-Wandler: Aktivierung des FPGA-Taktgenerators fehlgeschlagen 0
0x21EE49 EME, interner Fehler, DC/DC-Wandler, SPI-Kommunikation: Initialisierung der HW fehlgeschlagen 0
0x21EE4A EME, interner Fehler, DC/DC-Wandler, HW-Resetsignal: Initialisierung der HW fehlgeschlagen 0
0x21EE4B EME, interner Fehler, DC/DC-Wandler, Fehlerstatussignal: Initialisierung der HW fehlgeschlagen 0
0x21EE4C EME, interner Fehler, DC/DC-Wandler: Allgemeiner SPI-Kommunikationsfehler 0
0x21EE4D EME, interner Fehler, DC/DC-Wandler: Allgemeiner HW-Deinitialisierungsfehler 0
0x21EE4E EME, interner Fehler, DC/DC-Wandler: Zustand <Passive> unplausibel 0
0x21EE53 EME, interner Fehler, DC/DC-Wandler, Zwischenkreis: Überstrom erkannt (HW-Schwelle) 0
0x21EE54 EME, DC/DC, Zwischenkreisspannung im Tiefsetzbetrieb: Wert über 1. Spannungsschwelle (SW) 0
0x21EE55 EME, DC/DC, Zwischenkreisspannung, Überspannungsschutz: Wert über Spannungsschwelle (HW) 0
0x21EE56 EME, DC/DC, Zwischenkreisspannung im Tiefsetzbetrieb: Wert unter Spannungsschwelle (SW) 0
0x21EE57 EME, DC/DC, Zwischenkreisspannung: Wert unplausibel 0
0x21EE58 EME, DC/DC, Zwischenkreisspannung im Tiefsetzbetrieb: Wert über 2. Spannungsschwelle (SW) 0
0x21EE59 EME, DC/DC, Zwischenkreisspannung im Hochsetzbetrieb: Wert über Spannungsschwelle (SW) 0
0x21EE5A EME, DC/DC, Zwischenkreisspannung im Hochsetzbetrieb: Wert unter Spannungsschwelle (SW) 0
0x21EE5B EME, DC/DC, Bordnetzstrom im Tiefsetzbetrieb: Wert über Stromschwelle (SW) 0
0x21EE5C EME, DC/DC, Bordnetzstrom: Wert über Stromschwelle (HW) 0
0x21EE5D EME, DC/DC, Bordnetzspannung: Wert über Spannungsschwelle (HW) 0
0x21EE5E EME, DC/DC, Bordnetzspannung: Wert unter Spannungsschwelle (SW) 0
0x21EE5F EME, DC/DC, Bordnetzspannung: Wert unplausibel 0
0x21EE60 EME, DC/DC, Bordnetzstrom: Wert unplausibel 0
0x21EE61 EME, DC/DC, Bortnetzstrom im Hochsetzbetrieb: Wert über Stromschwelle (SW) 0
0x21EE62 EME, DC/DC, Bortnetzspannung im Hochsetzbetrieb: Wert über Spannungsschwelle (SW) 0
0x21EE63 EME, DC/DC, Bortnetzspannung im Tiefsetzbetrieb: Wert über Spannungsschwelle (SW) 0
0x21EE64 EME, interner Fehler, DC/DC: Zeitüberschreitung bei Konfiguration des Tiefsetzbetriebs 0
0x21EE67 EME, interner Fehler, DC/DC, interne Spannungsversorgung: 15V Schaltnetzteil defekt 0
0x21EE68 EME, interner Fehler, DC/DC, interne Spannungsversorgung: -7V Schaltnetzteil defekt 0
0x21EE69 EME, interner Fehler, DC/DC, interne Spannungsversorgung: 5V Schaltnetzteil defekt 0
0x21EE6C EME, interner Fehler, DC/DC: Wandler nicht vorhanden 0
0x21EE6D EME, interner Fehler, DC/DC-Wandler, HW-Initialisierung: Voraussetzung nicht erfüllt 0
0x21EE6E EME, interner Fehler, DC/DC-Wandler, Temperatursensor Leistungsstufe Hochvolt: Wert unplausibel 0
0x21EE6F EME, interner Fehler, DC/DC-Wandler, Temperatursensor Leistungsstufe Niedervolt: Wert unplausibel 0
0x21EE70 EME, interner Fehler, DC/DC-Wandler, Temperatursensor Transformator: Wert unplausibel 0
0x21EE71 EME, interner Fehler, DC/DC-Wandler, Temperatursensor Kontrollplatine: Wert unplausibel 0
0x21EE72 EME, interner Fehler, DC/DC: Sammelfehler der Klasse 1 0
0x21EE73 EME, interner Fehler, DC/DC: Sammelfehler der Klasse 2 0
0x21EE74 EME, interner Fehler, DC/DC: Sammelfehler der Klasse 3 0
0x21EE80 EME, Stromplausibilisierung der drei Phasen: Summe der Phasenströme außerhalb des erlaubten Bereichs 0
0x21EE88 EME, interner Fehler, Ebene 2: Summe der Phasenström außerhalb des erlaubten Bereichs. 0
0x21EE89 EME, interner Fehler, Ebene 2: ADCReady-Interrupt-Zähler hat zu hohen oder niedrigen Wert 0
0x21EE8B EME, interner Fehler, Ebene 2: Snapshot-Zähler hat zu hohen oder niedrigen Wert 0
0x21EE8D EME, interner Fehler, Ebene 2: Vergleicher, der Iq aus Ebene 1 und Ebene 2 vergleicht, schlägt an 0
0x21EE8E EME, interner Fehler, Ebene 2: Vergleicher, der den gefilterten Iq aus Ebene 1 und Ebene 2 vergleicht, schlägt an 0
0x21EE8F EME, interner Fehler, Ebene 2: Vergleicher, der das Ist-Moment aus Ebene 1 und Ebene 2 vergleicht, schlägt an 0
0x21EE90 EME, interner Fehler, Ebene 2: Vergleicher, der das Ist-Moment aus Ebene 2 mit dem zulässigen E2-Moment vergleicht, schlägt an 0
0x21EE91 EME, interner Fehler, Ebene 2: Winkelplausibiliesierung fehlgeschlagen 0
0x21EE92 EME, interner Fehler, Ebene 2: Drehzahlplausibilisierung fehlgeschlagen 0
0x21EE93 EME, interner Fehler, Ebene 2: Programmablauffehler 0
0x21EE94 EME, interner Fehler, Ebene 2: Redundante Datenablage ist nicht konsistent (ZFS) 0
0x21EE98 EME, interner Fehler, Ebene 2: Deaktivierung des OEM-Moduls 0
0x21EE99 EME, interner Fehler, Ebene 2: Ermittelter e-Offset außerhalb der Toleranz 0
0x21EE9A EME, interner Fehler, Ebene 2, Notlauf-Anforderung: Unterschied Level 1 und Level 2 0
0x21EE9B EME, interner Fehler, Ebene 2: Redundante Datenablage ist nicht konsistent (CAS) 0
0x21EE9C EME, interner Fehler, Ebene 2: Sensorwerte der Phasen U, V oder W außerhalb des gültigen Bereiches 0
0x21EE9D EME, interner Fehler, Ebene 2: Resetursachenermittelung konnte nicht aus dem EEPROM lesen 0
0x21EE9E EME, interner Fehler, Ebene 2: Resetursachenermittelung konnte die Überwachungsmodul-Resetinformationen nicht lesen 0
0x21EEA0 EME, interner Fehler, Ebene 3: die maximales Resetanzahl eines spezifischen Fehlers erreicht 0
0x21EEA1 EME, interner Fehler, Ebene 3: Reset durch externes Überwachungsmodul 0
0x21EEA8 EME, interner Fehler, Ebene 2: Watchdog CY320 kann nicht konfiguriert werden 0
0x21EEA9 EME, interner Fehler, Ebene 2: Fehlerzähler des Überwachungsmoduls ist größer 4 0
0x21EEAA EME, interner Fehler, Ebene 2: Fehlerzähler des Überwachungsmoduls verändert sich trotz Fehler nicht 0
0x21EEAB EME, interner Fehler, Ebene 2: Abschaltpfad (z.B. AKS) nicht aktiv, obwohl das Frage-Antwort-Verfahren im Tabellenmodus läuft 0
0x21EEC0 EME, interner Fehler, Temperatursensor der Kontrollleiterplatine: Wert unplausibel 0
0x21EEC1 EME, interner Fehler, Temperatursensor der Kontrollleiterplatine, Wertebereichsverletzung: Untere Schwelle 0
0x21EEC2 EME, interner Fehler, Temperatursensor der Kontrollleiterplatine, Wertebereichsverletzung: Obere Schwelle 0
0x21EEC4 Externer Temperatursensor E-Maschine Signal: Wert unplausibel 0
0x21EEC5 Externer Temperatursensor E-Maschine Signal Wertebereichsverletzung : Untere Schwelle 0
0x21EEC6 Externer Temperatursensor E-Maschine Signal Wertebereichsverletzung: Obere Schwelle 0
0x21EEC8 EME, interner Fehler, Temperatursensor Leistungselektronik Pulswechselrichter: Wert unplausibel 0
0x21EEC9 EME, interner Fehler, Temperatursensor Leistungselektronik, Pulswechselrichter, Wertebereichsverletzung: Untere Schwelle 0
0x21EECA EME, interner Fehler, Temperatursensor Leistungselektronik, Pulswechselrichter, Wertebereichsverletzung: Obere Schwelle 0
0x21EF00 Externer Rotorlagesensor Sinussignal: Wert unplausibel 0
0x21EF01 Externer Rotorlagesensor Sinussignal Wertebereichsverletzung: Untere Schwelle 0
0x21EF02 Externer Rotorlagesensor Sinussignal Wertebereichsverletzung: Obere Schwelle 0
0x21EF03 Externer Rotorlagesensor Cosinussignal: Wert unplausibel 0
0x21EF04 Externer Rotorlagesensor Cosinussignal Wertebereichsverletzung: Untere Schwelle 0
0x21EF05 Externer Rotorlagesensor Cosinussignal Wertebereichsverletzung: Obere Schwelle 0
0x21EF08 Interne EME Temperatur Kontrollleiterplatte: Obere Temperaturschwelle überschritten 0
0x21EF09 Interne EME-Temperatur Leistungselektronik Pulswechselrichter: Obere Temperaturschwelle überschritten 0
0x21EF0A Interne EME-Temperatur Leistungselektronik Pulswechselrichter: 1. Temperaturschwelle (Vorwarnung) überschritten 0
0x21EF0B Interne EME-Temperatur Leistungselektronik Pulswechselrichter: 2. Temperaturschwelle (Leistungsbegrenzung) überschritten 0
0x21EF0C EME, interner Fehler, Stromsensor Leistungselektronik, Pulswechselrichter, Wertebereichsverletzung: Ebene 1 0
0x21EF0D EME, interner Fehler, Stromsensor Leistungselektronik, Pulswechselrichter, Wertebereichsverletzung: Ebene 2 0
0x21EF0E Interne EME-Temperatur DC/DC-Wandler Trafo: Obere Temperaturschwelle überschritten 0
0x21EF0F Interne EME-Temperatur Leistungselektronik Pulswechselrichter: Temperaturgradient steigt zu stark 0
0x21EF10 EME, Stromsensor Phase U: Überstrom oder Sensor defekt 0
0x21EF11 EME, interner Fehler, Stromsensor Phase U: Wert unplausibel 0
0x21EF12 EME, interner Fehler, Stromsensor Phase U, Wertebereichsverletzung: Untere Schwelle 0
0x21EF13 EME, interner Fehler, Stromsensor Phase U, Wertebereichsverletzung: Obere Schwelle 0
0x21EF14 EME, interner Fehler, Stromsensor Phase U: defekt (anderer Stromsensor bereits als defekt detektiert) 0
0x21EF15 EME, interner Fehler, Stromsensor Phase U: Offset ausserhalb gültigen Bereichs (Ebene 1) 0
0x21EF16 EME, interner Fehler, Stromsensor Phase U,V oder W: Offset ausserhalb gültigen Bereichs (Ebene 2) 0
0x21EF18 EME, Stromsemnsor Phase V: Überstrom oder Sensor defekt 0
0x21EF19 EME, interner Fehler, Stromsensor Phase V: Wert unplausibel 0
0x21EF1A EME, interner Fehler, Stromsensor Phase V, Wertebereichsverletzung: Untere Schwelle 0
0x21EF1B EME, interner Fehler, Stromsensor Phase V, Wertebereichsverletzung: Obere Schwelle 0
0x21EF1C EME, interner Fehler, Stromsensor Phase V: defekt (anderer Stromsensor bereits als defekt detektiert) 0
0x21EF1D EME, interner Fehler, Stromsensor Phase V: Offset ausserhalb gültigen Bereichs (Ebene 1) 0
0x21EF20 EME, Stromsemnsor Phase W: Überstrom oder Sensor defekt 0
0x21EF21 EME, interner Fehler, Stromsensor Phase W: Wert unplausibel 0
0x21EF22 EME, interner Fehler, Stromsensor Phase W, Wertebereichsverletzung: Untere Schwelle 0
0x21EF23 EME, interner Fehler, Stromsensor Phase W, Wertebereichsverletzung: Obere Schwelle 0
0x21EF24 EME, interner Fehler, Stromsensor Phase W: defekt (anderer Stromsensor bereits als defekt detektiert) 0
0x21EF25 EME, interner Fehler, Stromsensor Phase W: Offset ausserhalb gültigen Bereichs (Ebene 1) 0
0x21EF30 EME, Phase U: Leistungsendstufe Highside defekt oder Leitungsschluss 0
0x21EF31 EME, Phase V: Leistungsendstufe Highside defekt oder Leitungsschluss 0
0x21EF32 EME, Phase W: Leistungsendstufe Highside defekt oder Leitungsschluss 0
0x21EF33 EME, Phase U: Leistungsendstufe Lowside defekt oder Leitungsschluss 0
0x21EF34 EME, Phase V: Leistungsendstufe Lowside defekt oder Leitungsschluss 0
0x21EF35 EME, Phase W: Leistungsendstufe Lowside defekt oder Leitungsschluss 0
0x21EF38 EME, interner Fehler, interne Spannungsversorgung: 5V Schaltnetzteil Lowside defekt 0
0x21EF39 EME, interner Fehler, interne Spannungsversorgung: 5V Schaltnetzteil Highside defekt 0
0x21EF3A EME, interner Fehler, interne Spannungsversorgung: 15V Schaltnetzteil Highside defekt 0
0x21EF40 EME, E-Maschinenregelung, E-Maschine: Ermittelter e-Offset außerhalb der Toleranz 0
0x21EF41 EME, E-Maschinenregelung, E-Maschine: Temperatur über 1. Schwelle 0
0x21EF42 EME, E-Maschinenregelung, E-Maschine: Temperatur über 2. Schwelle 0
0x21EF43 EME, E-Maschinenregelung, E-Maschine: Überdrehzahl erkannt 0
0x21EF44 EME, interner Fehler, Ebene 3: Watchdog Abschaltpfadtest fehlgeschlagen 0
0x21EF45 EME, interner Fehler, Ebene 3: CAN-Transceiver-Test fehlgeschlagen 0
0x21EF46 EME, interner Fehler, Ebene 3: Endstufen-Test fehlgeschlagen 0
0x21EF48 Externer Crashsensor: Crash detektiert (KL30C) 0
0x21EF4C EME, Hochvoltzwischenkreis: Überspannungsschutz des Pulswechselrichters (HW-Schwellenwerte) 0
0x21EF4D EME, Hochvoltzwischenkreis: Überspannungsschutz des Pulswechselrichters (SW-Schwellenwerte) 0
0x21EF4E EME, Hochvoltzwischenkreis: Unterspannungsschutz des Pulswechselrichters (SW-Schwellenwerte) 0
0x21EF4F EWP5: Kommunikationsfehler 0
0x21EF50 EWP5: Drehzahlabweichung 0
0x21EF51 EWP5, Leistungsreduzierung: Unter-/Übertemperatur 0
0x21EF52 EWP5, Leistungsreduzierung: Trockenlauf 0
0x21EF53 EWP5: Abschaltung aufgrund Überstrom/Überspannung 0
0x21EF54 EWP5: Abschaltung aufgrund Übertemperatur/Trockenlauf 0
0x21EF55 Ladekontrollleuchte aktiv 0
0x21EF7E EME, interner Fehler, interne Spannungsversorgung: Fehler im HF-Bus (Highside) 0
0x21EF7F EME, interner Fehler, interne Spannungsversorgung: Fehler im HF-Bus (Lowside) 0
0x21EF82 Energetische Betriebsstrategie: Anforderung der Ladezustandsregelung nicht erfüllt (Batterie laden) 0
0x21EF83 EME, interner Fehler, DC/DC-Wandler: Kein Leistungstransfer - Zustand unplausibel 0
0x21EF85 DSC, OBD: Bremssystem-Steuergerät - interner Hardware Fehler 0
0x21EF86 DSC, OBD: Bremspedal Positionssensor Schaltkreis - Fehlfunktion oder Leitungsunterbrechung 0
0x21EF87 DSC, OBD: Bremspedal Positionssensor - Unterspannung 0
0x21EF88 EME, interner Fehler, DC/DC, Temperatursensor der Hochvolt-Leistungsendstufe: Wert unplausibel 0
0x21EF89 EME, interner Fehler, DC/DC, Temperatursensor der Niedervolt-Leistungsendstufe: Wert unplausibel 0
0x21EF8A EME, interner Fehler, DC/DC, Temperatursensor des Transformators: Wert unplausibel 0
0x21EF8B EME, interner Fehler, CPLD: Initialisierung fehlgeschlagen 0
0x21EF8C Ebene 2: CAN-Botschaften: Botschaftsfolgezähler fehlerhaft 1
0x21EF8D Ebene 2: CAN-Botschaften: CRC der Nutzdaten fehlerhaft 1
0x21EF8E Ebene 2: CAN-Botschaften: Ausfall 1
0x21EF8F Ebene 2: BMW-Modul erkennt Fehler 0
0x21EF90 Externer Crashsensor: Crash detektiert (CAN) 0
0x21EF91 BMW: NLM CAN Signalausfall von DME 0
0x21EF92 BMW: NLM CAN Signalausfall von IHKA, DSC, ICM 0
0x21EF93 BMW: NLM CAN Signalausfall von LE, DCDC 0
0x21EF94 BMW: NLM CAN Signalausfall von SME 0
0x21EF95 DSC, OBD: Bremspedal Positionssensor - elektrischer Fehler oder Sensor defekt 0
0x21EF96 DSC, OBD: Bremspedal Positionssensor - Überspannung 0
0x21EF97 DSC, OBD: Bremspedal Positionssensor Schaltkreis - niedrig 0
0x21EF98 DSC, OBD: Bremspedal Positionssensor Schaltkreis - hoch 0
0x21EF99 DSC, OBD: Bremspedal Positionssensor - Gradient zu hoch 0
0x21EF9A DSC, OBD: Bremspedal Positionssensor - Gradient zu niedrig 0
0x21EF9B DSC, OBD: Bremskraftverstärker Drucksensor Schaltkreis - niedrig 0
0x21EF9C DSC, OBD: Bremskraftverstärker Drucksensor Schaltkreis - hoch 0
0x21EF9D DSC, OBD: Bremssystem Überwachung DSC (Dynamic Stability Control) 0
0x21EF9E DSC, OBD: Bremssystem-Steuergerät Kommunikationsverlust mit Motorsteuergerät 0
0x21EF9F DSC, OBD: Bremspedal Positionssensor Schaltkreis - Messbereichs- oder Leistungsproblem 0
0x21EFA0 DSC, OBD: Bremspedal Positionssensor Schaltkreis Messbereichs- oder Leistungsproblem - Signal zu hoch 0
0x21EFA1 DSC, OBD: Bremspedal Positionssensor Schaltkreis Messbereichs- oder Leistungsproblem - Signal zu niedrig 0
0x21EFA2 DSC, OBD: Bremskraftverstärker Drucksensor Schaltkreis - Messbereichs- oder Leistungsproblem 0
0x21EFA3 DSC, OBD: Bremskraftverstärker Drucksensor - Testpuls hoch 0
0x21EFA4 DSC, OBD: Bremskraftverstärker Drucksensor - Testpuls niedrig 0
0xCF840A EME, CAN: FA-CAN wurde getrennt 1
0xCF8490 EME, CAN: H-CAN wurde getrennt 1
0xCF8491 EME, CAN: A-CAN wurde getrennt 1
0xCF8492 EME, CAN: Applikations-CAN wurde getrennt 1
0xCF8500 Botschaft (Winkel_Fahrpedal, FA-CAN, 0x0D9): Botschaftsfolgezähler fehlerhaft 1
0xCF8501 Botschaft (Diagnose OBD Hybrid 1, FA-CAN, 0x416): Botschaftsfolgezähler fehlerhaft 1
0xCF8504 Botschaft (Daten Antriebsstrang 2, FA-CAN, 0x3F9): Botschaftsfolgezähler fehlerhaft 1
0xCF8505 Botschaft (Anforderung Drehmoment Antrieb Hybrid, A-CAN, 0x0FF): Botschaftsfolgezähler fehlerhaft 1
0xCF8506 Botschaft (Drehmoment Kurbelwelle 1, FA-CAN, 0x0A5): Botschaftsfolgezähler fehlerhaft 1
0xCF8507 Botschaft (Drehmoment Kurbelwelle Hybrid, H-CAN, 0x10E): Botschaftsfolgezähler fehlerhaft 1
0xCF8509 Botschaft (Status Dynamisch Spannung Hochvoltspeicher, A-CAN, 0x182): Botschaftsfolgezähler fehlerhaft 1
0xCF850A Botschaft (RESI_HVSTO, A-CAN, 0x406): Botschaftsfolgezähler fehlerhaft 1
0xCF850B Botschaft (Ladung Hochvoltspeicher, A-CAN, 0x404): Botschaftsfolgezähler fehlerhaft 1
0xCF850C Botschaft (Daten Antriebsstrang 2, FA-CAN, 0x3F9): Botschaftsfolgezähler fehlerhaft 1
0xCF850D Botschaft (Status Motor Start Auto, FA-CAN, 0x30B): Botschaftsfolgezähler fehlerhaft 1
0xCF850E Botschaft (Anforderung Drehmoment Fahrerwunsch Hybrid, H-CAN, 0x10D): Botschaftsfolgezähler fehlerhaft 1
0xCF8600 Botschaft (Winkel_Fahrpedal, FA-CAN, 0x0D9): CRC der Nutzdaten fehlerhaft 1
0xCF8602 Botschaft (Daten Antriebsstrang 2, FA-CAN, 0x3F9): CRC der Nutzdaten fehlerhaft 1
0xCF8603 Botschaft (Anforderung Drehmoment Antrieb Hybrid, A-CAN, 0x0FF): CRC der Nutzdaten fehlerhaft 1
0xCF8604 Botschaft (Drehmoment Kurbelwelle 1, FA-CAN, 0x0A5): CRC der Nutzdaten fehlerhaft 1
0xCF8605 Botschaft (Drehmoment Kurbelwelle Hybrid, H-CAN, 0x10E): CRC der Nutzdaten fehlerhaft 1
0xCF8607 Botschaft (RESI_HVSTO, A-CAN, 0x406): CRC der Nutzdaten fehlerhaft 1
0xCF8608 Botschaft (Ladung Hochvoltspeicher, A-CAN, 0x404): CRC der Nutzdaten fehlerhaft 1
0xCF8609 Botschaft (Status Dynamisch Spannung Hochvoltspeicher, A-CAN, 0x182): CRC der Nutzdaten fehlerhaft 1
0xCF860A Botschaft (Daten Antriebsstrang 2, FA-CAN, 0x3F9): CRC der Nutzdaten fehlerhaft 1
0xCF860B Botschaft (Status Motor Start Auto, FA-CAN, 0x30B): CRC der Nutzdaten fehlerhaft 1
0xCF860C Botschaft (Anforderung Drehmoment Fahrerwunsch Hybrid, H-CAN, 0x10D): CRC der Nutzdaten fehlerhaft 1
0xCF8700 Botschaft (Außentemperatur, FA-CAN, 0x2CA): Ausfall 1
0xCF8701 Botschaft (Winkel_Fahrpedal, FA-CAN, 0x0D9): Ausfall 1
0xCF8702 Botschaft (Ist Drehzahl Rad ungesichert, FA-CAN, 0x254): Ausfall 1
0xCF8703 Botschaft (Bordnetz Spannungswert, FA-CAN, 0x281): Ausfall 1
0xCF8704 Botschaft (Steuerung Kühlung Antrieb Elektrisch, A-CAN, 0x340): Ausfall 1
0xCF8705 Botschaft (Steuerung Crashabschaltung EKP, FA-CAN, 0x135): Ausfall 1
0xCF8706 Botschaft (Diagnose OBD Motor, FA-CAN, 0x397): Ausfall 1
0xCF8707 Botschaft (Diagnose OBD Hybrid 1, FA-CAN, 0x416): Ausfall 1
0xCF870A Botschaft (Daten Anzeige Getriebestrang, FA-CAN, 0x3FD): Ausfall 1
0xCF870B Botschaft (Daten Getriebestrang, FA-CAN, 0x1AF): Ausfall 1
0xCF870C Botschaft (Daten Antriebsstrang 1, FA-CAN, 0x3FB): Ausfall 1
0xCF870D Botschaft (Daten Antriebsstrang 2, FA-CAN, 0x3F9): Ausfall 1
0xCF870E Botschaft (Fahrzeugzustand, FA-CAN, 0x3A0): Ausfall 1
0xCF870F Botschaft (Identifikation Hochvoltspeicher, A-CAN, 0x363): Ausfall 1
0xCF8710 Botschaft (Klemmen, FA-CAN, 0x12F): Ausfall 1
0xCF8711 Botschaft (Begrenzung Ladung Entladung Hochvoltspeicher, A-CAN, 0x2F5): Ausfall 1
0xCF8712 Botschaft (Powermanagement Niederspannung, H-CAN, 0x3C9): Ausfall 1
0xCF8713 Botschaft (Relativzeit, FA-CAN, 0x328): Ausfall 1
0xCF8714 Botschaft (Freigabe Kühlung Hochvoltspeicher, FA-CAN, 0x37B): Ausfall 1
0xCF8715 Botschaft (Anforderung Klimaanlage, FA-CAN, 0x2F9): Ausfall 1
0xCF8716 Botschaft (Anforderung Drehmoment Antrieb Hybrid, A-CAN, 0x0FF): Ausfall 1
0xCF8717 Botschaft (Status Gurt Kontakt Sitzbelegung, FA-CAN, 0x297): Ausfall 1
0xCF8718 Botschaft (Status Getriebesteuergerät, A-CAN, 0x39A): Ausfall 1
0xCF8719 Botschaft (Status Hochvoltspeicher 1, A-CAN, 0x1FA): Ausfall 1
0xCF871A Botschaft (Status Hybrid 2, A-CAN, 0x418): Ausfall 1
0xCF871B Botschaft (Status Stabilisierung DSC, FA-CAN, 0x173): Ausfall 1
0xCF871C Botschaft (Status Motor Start Auto, FA-CAN, 0x30B): Ausfall 1
0xCF871E Botschaft (Status Hochvoltspeicher 2, A-CAN, 0x112): Ausfall 1
0xCF871F Botschaft (ZV und Klappenzustand, FA-CAN, 0x2FC): Ausfall 1
0xCF8720 Botschaft (SVC_IHKA, FA-CAN, 0x5F8): Ausfall 1
0xCF8721 Botschaft (Drehmoment Kurbelwelle 1, FA-CAN, 0x0A5): Ausfall 1
0xCF8722 Botschaft (Drehmoment Kurbelwelle Hybrid, H-CAN, 0x10E): Ausfall 1
0xCF8724 Botschaft (Geschwindigkeit Fahrzeug, FA-CAN, 0x1A1): Ausfall 1
0xCF8725 Botschaft (Radmoment Antrieb 4, FA-CAN, 0x0DC): Ausfall 1
0xCF8728 Botschaft (RESI_HVSTO, A-CAN, 0x406): Ausfall 1
0xCF8729 Botschaft (Status Dynamisch Spannung Hochvoltspeicher, A-CAN, 0x182): Ausfall 1
0xCF872A Botschaft (Ladung Hochvoltspeicher, A-CAN, 0x404): Ausfall 1
0xCF872B Botschaft (Status Betriebsart Hybrid 2, A-CAN, 0x41C): Ausfall 1
0xCF872E Botschaft (Anforderung Drehmoment Fahrerwunsch Hybrid, H-CAN, 0x10D): Ausfall 1
0xCF8731 Botschaft (Konfiguration Schalter Fahrdynamik, FA-CAN, 0x3A7): Ausfall 1
0xCF8732 Botschaft (Ist Bremsmoment Summe, FA-CAN, 0x0EF): Ausfall 1
0xCF8733 Botschaft (Kilometerstand/Reichweite, A-CAN, 0x330): Ausfall 1
0xCF8734 Botschaft (OBD Anfrage Begrenzung Drehmoment, A-CAN, 0x41D): Ausfall 1
0xCF8735 Botschaft (Nachlaufzeit Stromversorgung, FA-CAN, 0x3BE): Ausfall 1
0xCF8736 Botschaft (Drehmoment Kurbelwelle 3, A-CAN, 0x0A7): Ausfall 1
0xCF8737 Botschaft (Daten Antriebsstrang 2, FA-CAN, 0x3F9): Ausfall 1
0xCF8BFF Dummy-DTC: Netzwerkfehler zum Testen 1
0xFFFFFF unbekannter Fehlerort 0

RES_0X6301

Dimensions: 9 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_E_MOTOR_WERT °C high int - - - 64 - E-Motor-Temperatur
STAT_DCB_WERT °C high int - - - 64 - DCB-Temperatur
STAT_CONTROL_BOARD_WERT °C high int - - - 64 - Control-Board-Temperatur
STAT_E_MOTOR_MIN_WERT °C high int - - - 64 - minimale gültige E-Motor-Temperatur -40°C
STAT_E_MOTOR_MAX_WERT °C high int - - - 64 - maximale gültige E-Motor-Temperatur +180°C
STAT_DCB_MIN_WERT °C high int - - - 64 - minimale gültige DCB-Temperatur -40°C
STAT_DCB_MAX_WERT °C high int - - - 64 - maximale gültige DCB-Temperatur +105°C
STAT_CONTROL_BOARD_MIN_WERT °C high int - - - 64 - minimale gültige Control-Board-Temperatur-Temperatur -40°C
STAT_CONTROL_BOARD_MAX_WERT °C high int - - - 64 - maximale gültige Control-Board-Temperatur-Temperatur +125°C

RES_0X6306

Dimensions: 4 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_STROM_DC_WERT A - int - - 1 10 0 HV-Strom Bordnetz
STAT_STROM_AC_EFF_W_WERT A - int - - 1 16 0 Effektiver Zuleitungsstrom Phase W
STAT_STROM_AC_EFF_V_WERT A - int - - 1 16 0 Effektiver Zuleitungsstrom Phase V
STAT_STROM_AC_EFF_U_WERT A - int - - 1 16 0 Effektiver Zuleitungsstrom Phase U

RES_0X6308

Dimensions: 3 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_KL50L_NR 0-n - unsigned char - TAB_STAT_KL50L_NR - - - Status Klemme 50
STAT_SPANNUNG_UBAT_WERT V - unsigned int - - 0.015 - - Spannung 12V Bordnetz
STAT_STROM_UBAT_WERT A - unsigned int - - 0.08 - -200 Strom 12V Bordnetz

RES_0X6309

Dimensions: 3 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ELEKTRISCHE_MASCHINE_DREHZAHL_WERT 1/min - unsigned int - - - 2 -5000 Drehzahl der E-Maschine
STAT_ELEKTRISCHE_MASCHINE_IST_MOMENT_WERT Nm - int - - - 2 - Tatsächliches Moment der E-Maschine
STAT_ELEKTRISCHE_MASCHINE_SOLL_MOMENT_WERT Nm - int - - - 2 - Vorgegebenes Moment der E-Maschine

RES_0X630A

Dimensions: 2 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_DCDC_LADEMODUS_NR 0-n - unsigned char - TAB_STAT_DCDC_LADEMODUS_NR - - - Abfrage des DC/DC-Wandlers nach Betriebsmodus
STAT_LADUNG_HV_BATTERIE_BSW_WERT % - unsigned int - - - 10 - Istwert Ladezustand Batterie

RES_0X630B

Dimensions: 1 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_EME_ANTRIEBSART_NR 0-n - unsigned char - TAB_STAT_EME_ANTRIEBSART_NR - - - Rückmeldung der aktuell anliegenden Antriebsart. z.B. Rekuperation, Boost etc.

RES_0X6310

Dimensions: 1 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_KL30C_STATUS 0-n - unsigned char - TAB_KL30C_STATUS - - - 0=Crash nicht erkannt, 1=Crash erkannt

RES_0X6316

Dimensions: 2 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_EMK_STROM_DC_WERT A - signed int - - 0.25 - 0 -
STAT_SPANNUNG_DCDC_LV_WERT V - unsigned int - - 0.1 - 0 -

RES_0X6320

Dimensions: 17 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HVB_WERT % - unsigned int - - 0.1 - 0 -
STAT_SOC_HVB_MIN_WERT % - signed long - - 1 - 0 -
STAT_LADEGERAET 0/1 - unsigned char - - 1 - 0 -
STAT_FREMDLADUNG 0/1 - unsigned char - - 1 - 0 -
STAT_FAHRB 0/1 - unsigned char - - 1 - 0 -
STAT_PWR_LOW 0/1 - unsigned char - - 1 - 0 -
STAT_BA_DCDC_KOMM_WERT - - unsigned char - - 1 - 0 -
STAT_I_DCDC_HV_OUT_WERT A - signed int - - 0.1 - 0 -
STAT_U_DCDC_HV_OUT_WERT V - unsigned int - - 0.1 - 0 -
STAT_I_DCDC_LV_OUT_WERT A - signed int - - 1 - 0 -
STAT_U_DCDC_LV_OUT_WERT V - unsigned int - - 0.1 - 0 -
STAT_BA_DCDC_IST_WERT - - unsigned char - - 1 - 0 -
STAT_ALS_DCDC_WERT % - unsigned char - - 0.5 - 0 -
STAT_I_DCDC_HV_WERT A - signed int - - 0.1 - 0 -
STAT_U_DCDC_HV_WERT V - unsigned int - - 0.1 - 0 -
STAT_I_DCDC_LV_WERT A - signed int - - 1 - 0 -
STAT_U_DCDC_LV_WERT V - unsigned int - - 0.1 - 0 -

RES_0X6321

Dimensions: 11 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_P_EM1_GEN_MAX_WERT W - signed long - - 1 - 0 -
STAT_P_HVB_MOT_1S_WERT W - signed long - - 1 - 0 -
STAT_P_WUNSCH_SOCR_WERT W - signed long - - 1 - 0 -
STAT_P_BN_WERT - - signed long - - 1 - 0 -
STAT_ANF_ANTRIEB_WERT - - unsigned char - - 1 - 0 -
STAT_ANF_ANTRIEB_FUNK_WERT - - unsigned char - - 1 - 0 -
STAT_ANF_DCDC_ENTL 0/1 - unsigned char - - 1 - 0 -
STAT_ANF_DCDC_AUS 0/1 - unsigned char - - 1 - 0 -
STAT_ANF_EKMV_AUS 0/1 - unsigned char - - 1 - 0 -
STAT_SCHUBPHASE 0/1 - unsigned char - - 1 - 0 -
STAT_ANF_MIN_BUCK 0/1 - unsigned char - - 1 - 0 -

RES_0X6322

Dimensions: 13 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_INLK_DCDC_WERT - - unsigned char - - 1 - 0 -
STAT_INLK_LE 0/1 - unsigned char - - 1 - 0 -
STAT_FL_HV_ANF 0/1 - unsigned char - - 1 - 0 -
STAT_KL30C 0/1 - unsigned char - - 1 - 0 -
STAT_HV_EIN_ANF 0/1 - unsigned char - - 1 - 0 -
STAT_HV_EIN 0/1 - unsigned char - - 1 - 0 -
STAT_HV_AUS_ANF 0/1 - unsigned char - - 1 - 0 -
STAT_HV_AUS 0/1 - unsigned char - - 1 - 0 -
STAT_U_DC_HV_LE_WERT V - unsigned int - - 0.25 - 0 -
STAT_HV_READY 0/1 - unsigned char - - 1 - 0 -
STAT_HDCAC_EREQ 0/1 - unsigned char - - 1 - 0 -
STAT_I0ANF_HVB 0/1 - unsigned char - - 1 - 0 -
STAT_ANF_ENTL_DCDC 0/1 - unsigned char - - 1 - 0 -

RES_0X6323

Dimensions: 34 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_NV_MSA_DCDC_WERT Ah - unsigned int - - 1 - 0 -
STAT_NV_MSA_EKK_WERT Ah - signed long - - 1 - 0 -
STAT_NV_ENTL_EKK_STD_WERT Ah - signed long - - 1 - 0 -
STAT_NV_ENTL_EKK15_WERT Ah - signed long - - 1 - 0 -
STAT_NV_ENTL_DCDC15_WERT Ah - signed long - - 1 - 0 -
STAT_NV_ENTL_EM1_WERT Ah - signed long - - 1 - 0 -
STAT_NV_ENTL_EKK_WERT Ah - signed long - - 1 - 0 -
STAT_NV_ENTL_DCDC_WERT Ah - signed long - - 1 - 0 -
STAT_NV_MSA_EM1_WERT Ah - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_NULL_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_1_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_2_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_3_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_4_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_5_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_6_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_7_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_8_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_9_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_10_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_11_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_12_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_13_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_14_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_15_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_16_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_17_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_18_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_19_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_20_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_21_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_22_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_23_WERT s - signed long - - 1 - 0 -
STAT_NV_UHVB_SB_24_WERT s - signed long - - 1 - 0 -

RES_0X6324

Dimensions: 45 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_NV_KM_SOC_LOW_MSAAV_DEAKT_WERT km - unsigned int - - 1 - 0 -
STAT_NV_ANZ_SOC_LOW_MSAAV_AKT_WERT 0 - unsigned int - - 1 - 0 -
STAT_NV_KM_SOC_LOW_MSAAV_AKT_WERT km - unsigned int - - 1 - 0 -
STAT_NV_KM_SOC_HIGH_MSAAV_DEAKT_WERT km - unsigned int - - 1 - 0 -
STAT_NV_ANZ_SOC_HIGH_MSAAV_AKT_WERT 0 - unsigned int - - 1 - 0 -
STAT_NV_KM_SOC_HIGH_MSAAV_AKT_WERT km - unsigned int - - 1 - 0 -
STAT_NV_KM_HVPM_MSAAV_DEAKT_WERT km - unsigned int - - 1 - 0 -
STAT_NV_KM_HVPM_MSAAV_AKT_WERT km - unsigned int - - 1 - 0 -
STAT_NV_T_MSA_STOP_WERT s - unsigned long - - 1 - 0 -
STAT_NV_ANZ_MSA_STOP_KL5S_WERT 0 - unsigned long - - 1 - 0 -
STAT_NV_ANZ_MSA_STOP_GR5S_KL20S_WERT 0 - unsigned long - - 1 - 0 -
STAT_NV_ANZ_MSA_STOP_GR20S_KL60S_WERT 0 - unsigned long - - 1 - 0 -
STAT_NV_ANZ_MSA_STOP_GR60S_KL180S_WERT 0 - unsigned long - - 1 - 0 -
STAT_NV_ANZ_MSA_STOP_GR180S_WERT 0 - unsigned long - - 1 - 0 -
STAT_NV_PRZ_EA_SOC_LOW_KURZ_WERT % - unsigned char - - 1 - 0 -
STAT_NV_PRZ_EA_SOC_LOW_LANG_WERT % - unsigned char - - 1 - 0 -
STAT_NV_PRZ_EA_SOC_HIGH_KURZ_WERT % - unsigned char - - 1 - 0 -
STAT_NV_PRZ_EA_SOC_HIGH_LANG_WERT % - unsigned char - - 1 - 0 -
STAT_NV_PRZ_EA_PWRLOW_KURZ_WERT % - unsigned char - - 1 - 0 -
STAT_NV_PRZ_EA_PWRLOW_LANG_WERT % - unsigned char - - 1 - 0 -
STAT_NV_PRZ_EA_TEMP_KURZ_WERT % - unsigned char - - 1 - 0 -
STAT_NV_PRZ_EA_TEMP_LANG_WERT % - unsigned char - - 1 - 0 -
STAT_NV_PRZ_AV_SOC_LOW_KURZ_WERT % - unsigned char - - 1 - 0 -
STAT_NV_PRZ_AV_SOC_LOW_LANG_WERT % - unsigned char - - 1 - 0 -
STAT_NV_PRZ_AV_SOC_HIGH_KURZ_WERT % - unsigned char - - 1 - 0 -
STAT_NV_PRZ_AV_SOC_HIGH_LANG_WERT % - unsigned char - - 1 - 0 -
STAT_NV_PRZ_AV_PWRLOW_KURZ_WERT % - unsigned char - - 1 - 0 -
STAT_NV_PRZ_AV_PWRLOW_LANG_WERT % - unsigned char - - 1 - 0 -
STAT_NV_PRZ_AV_TEMP_KURZ_WERT % - unsigned char - - 1 - 0 -
STAT_NV_PRZ_AV_TEMP_LANG_WERT % - unsigned char - - 1 - 0 -
STAT_NV_T_FZG_STOP_WERT s - unsigned long - - 1 - 0 -
STAT_NV_ANZ_FZG_STOP_WERT 0 - unsigned long - - 1 - 0 -
STAT_NV_KM_HVPM_MSAEA_AKT_WERT km - unsigned int - - 1 - 0 -
STAT_NV_KM_HVPM_MSAEA_DEAKT_WERT km - unsigned int - - 1 - 0 -
STAT_NV_ANZ_HVPM_MSAEA_AKT_WERT 0 - unsigned int - - 1 - 0 -
STAT_NV_ANZ_HVPM_MSAAV_AKT_WERT 0 - unsigned int - - 1 - 0 -
STAT_NV_KM_PWR_LOW_MSAEA_AKT_WERT km - unsigned int - - 1 - 0 -
STAT_NV_KM_PWR_LOW_MSAEA_DEAKT_WERT km - unsigned int - - 1 - 0 -
STAT_NV_ANZ_PWR_LOW_MSAEA_AKT_WERT 0 - unsigned int - - 1 - 0 -
STAT_NV_KM_PWR_LOW_MSAAV_AKT_WERT km - unsigned int - - 1 - 0 -
STAT_NV_KM_PWR_LOW_MSAAV_DEAKT_WERT km - unsigned int - - 1 - 0 -
STAT_NV_ANZ_PWR_LOW_MSAAV_AKT_WERT 0 - unsigned int - - 1 - 0 -
STAT_NV_KM_TEMP_HVB_MSAEA_AKT_WERT km - unsigned int - - 1 - 0 -
STAT_NV_KM_TEMP_HVB_MSAEA_DEAKT_WERT km - unsigned int - - 1 - 0 -
STAT_NV_ANZ_TEMP_HVB_MSAEA_AKT_WERT 0 - unsigned int - - 1 - 0 -

RES_0X6325

Dimensions: 23 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_NV_KM_DEG_EKMV_VM_AN_A_WERT km - unsigned int - - 1 - 0 -
STAT_NV_T_DEG_EKMV_VM_AN_A_WERT min - unsigned char - - 1 - 0 -
STAT_NV_KM_DEG_BUCK_VM_AN_A_WERT km - unsigned int - - 1 - 0 -
STAT_NV_T_DEG_BUCK_VM_AN_A_WERT min - unsigned char - - 1 - 0 -
STAT_NV_KM_DEG_EKMV_VM_AUS_A_WERT km - unsigned int - - 1 - 0 -
STAT_NV_T_DEG_EKMV_VM_AUS_A_WERT min - unsigned char - - 1 - 0 -
STAT_NV_KM_DEG_BUCK_VM_AUS_A_WERT km - unsigned int - - 1 - 0 -
STAT_NV_T_DEG_BUCK_VM_AUS_A_WERT min - unsigned char - - 1 - 0 -
STAT_NV_KM_DEG_EKMV_VM_AN_B_WERT km - unsigned int - - 1 - 0 -
STAT_NV_T_DEG_EKMV_VM_AN_B_WERT min - unsigned char - - 1 - 0 -
STAT_NV_KM_DEG_BUCK_VM_AN_B_WERT km - unsigned int - - 1 - 0 -
STAT_NV_T_DEG_BUCK_VM_AN_B_WERT min - unsigned char - - 1 - 0 -
STAT_NV_T_DEG_EKMV_VM_AUS_B_WERT min - unsigned char - - 1 - 0 -
STAT_NV_KM_DEG_BUCK_VM_AUS_B_WERT km - unsigned int - - 1 - 0 -
STAT_NV_T_DEG_BUCK_VM_AUS_B_WERT min - unsigned char - - 1 - 0 -
STAT_NV_KM_DEG_EM1_LL_A_WERT km - unsigned int - - 1 - 0 -
STAT_NV_T_DEG_EM1_LL_A_WERT min - unsigned char - - 1 - 0 -
STAT_NV_KM_DEG_EM1_LL_B_WERT km - unsigned int - - 1 - 0 -
STAT_NV_T_DEG_EM1_LL_B_WERT min - unsigned char - - 1 - 0 -
STAT_NV_KM_DEG_EM1_NOTLL_A_WERT km - unsigned int - - 1 - 0 -
STAT_NV_T_DEG_EM1_NOTLL_A_WERT min - unsigned char - - 1 - 0 -
STAT_NV_KM_DEG_EM1_NOTLL_B_WERT km - unsigned int - - 1 - 0 -
STAT_NV_T_DEG_EM1_NOTLL_B_WERT min - unsigned char - - 1 - 0 -

RES_0X632D

Dimensions: 2 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_KM_TAUSCH_1_WERT km - unsigned long - - 1 - 0 -
STAT_KM_TAUSCH_2_WERT km - unsigned long - - 1 - 0 -

RES_0X632E

Dimensions: 4 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_LADUNG_GESAMT_WERT As - unsigned long - - 1 - 0 -
STAT_ENTLADUNG_GESAMT_WERT As - unsigned long - - 1 - 0 -
STAT_LADUNGSMENGE_BOOST_WERT As - unsigned long - - 1 - 0 -
STAT_LADUNGSMENGE_RECUP_WERT As - unsigned long - - 1 - 0 -

RES_0X6314

Dimensions: 3 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_TEMP_SG_WERT_DCDC_TRAFO_WERT °C - signed int - - 1 - 0 -
STAT_TEMP_SG_WERT_DCDC_SCHALTER_HV_WERT °C - signed int - - 1 - 0 -
STAT_TEMP_SG_WERT_DCDC_SCHALTER_LV_WERT °C - signed int - - 1 - 0 -

RES_0X6318

Dimensions: 4 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_EPI_XMUL_WERT - - unsigned int - - 0.00006103515625 - 0 -
STAT_EPI_YMUL_WERT - - unsigned int - - 0.00006103515625 - 0 -
STAT_EPI_XOFF_WERT - - unsigned int - - 0.000152587890625 - 0 -
STAT_EPI_YOFF_WERT - - unsigned int - - 0.000152587890625 - 0 -

RES_0X6319

Dimensions: 1 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ERSTSTARTBEGRAKTIV_WERT - - unsigned char - - 1 - 0 -

RES_0X631B

Dimensions: 2 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_DC_STROMDERATING_POS_WERT % - unsigned int - - 1 - 0 -
STAT_DC_STROMDERATING_NEG_WERT % - unsigned int - - 1 - 0 -

RES_0X636E

Dimensions: 8 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ZEIT_TEMPERATUR_HVBATTERIE_SMALLER_0C_WERT min - unsigned long - - 1 - 0 -
STAT_ZEIT_TEMPERATUR_HVBATTERIE_0C_10C_WERT min - unsigned long - - 1 - 0 -
STAT_ZEIT_TEMPERATUR_HVBATTERIE_10C_20C_WERT min - unsigned long - - 1 - 0 -
STAT_ZEIT_TEMPERATUR_HVBATTERIE_20C_30C_WERT min - unsigned long - - 1 - 0 -
STAT_ZEIT_TEMPERATUR_HVBATTERIE_30C_40C_WERT min - unsigned long - - 1 - 0 -
STAT_ZEIT_TEMPERATUR_HVBATTERIE_40C_45C_WERT min - unsigned long - - 1 - 0 -
STAT_ZEIT_TEMPERATUR_HVBATTERIE_45C_50C_WERT min - unsigned long - - 1 - 0 -
STAT_ZEIT_TEMPERATUR_HVBATTERIE_GR_50C_WERT min - unsigned long - - 1 - 0 -

RES_0X636F

Dimensions: 8 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_TIME_IN_SOC_SINCE_SOP_0_40_WERT min - unsigned long - - 1 - 0 -
STAT_TIME_IN_SOC_SINCE_SOP_40_50_WERT min - unsigned long - - 1 - 0 -
STAT_TIME_IN_SOC_SINCE_SOP_50_54_WERT min - unsigned long - - 1 - 0 -
STAT_TIME_IN_SOC_SINCE_SOP_54_58_WERT min - unsigned long - - 1 - 0 -
STAT_TIME_IN_SOC_SINCE_SOP_58_62_WERT min - unsigned long - - 1 - 0 -
STAT_TIME_IN_SOC_SINCE_SOP_62_66_WERT min - unsigned long - - 1 - 0 -
STAT_TIME_IN_SOC_SINCE_SOP_66_70_WERT min - unsigned long - - 1 - 0 -
STAT_TIME_IN_SOC_SINCE_SOP_70_100_WERT min - unsigned long - - 1 - 0 -

RES_0X636D

Dimensions: 8 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_I_HISTO_KL_MIN160A_WERT s - unsigned long - - 1 - 0 -
STAT_I_HISTO_GRGL_MIN160A_KL_MIN80A_WERT s - unsigned long - - 1 - 0 -
STAT_I_HISTO_GRGL_MIN80A_KL_MIN5A_WERT s - unsigned long - - 1 - 0 -
STAT_I_HISTO_GRGL_MIN5A_KL_0A_WERT s - unsigned long - - 1 - 0 -
STAT_I_HISTO_GRGL_0A_KL_5A_WERT s - unsigned long - - 1 - 0 -
STAT_I_HISTO_GRGL_5A_KL_80A_WERT s - unsigned long - - 1 - 0 -
STAT_I_HISTO_GRGL_80A_KL_160A_WERT s - unsigned long - - 1 - 0 -
STAT_I_HISTO_GRGL_160A_WERT s - unsigned long - - 1 - 0 -

RES_0X6336

Dimensions: 7 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_DAUER_TEMP_60_80_WERT h - unsigned int - - 1 - 0 -
STAT_DAUER_TEMP_GR_80_WERT h - unsigned int - - 1 - 0 -
STAT_DAUER_TEMP_KL_MIN_40_WERT h - unsigned int - - 1 - 0 -
STAT_DAUER_LADESTROM_ZU_HOCH_WERT h - unsigned long - - 1 - 0 -
STAT_DAUER_ENTLADESTROM_ZU_HOCH_WERT h - unsigned long - - 1 - 0 -
STAT_DAUER_SPANNUNG_ZU_NIEDRIG_WERT h - unsigned long - - 1 - 0 -
STAT_DAUER_SPANNUNG_ZU_HOCH_WERT h - unsigned long - - 1 - 0 -

RES_0X6351

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_RI_ENTLADEN_FUER_T1_UND_SOC_30_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T1_UND_SOC_40_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T1_UND_SOC_50_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T1_UND_SOC_60_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T1_UND_SOC_70_WERT Ohm - unsigned int - - 1 - 0 -

RES_0X6352

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_RI_ENTLADEN_FUER_T2_UND_SOC_30_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T2_UND_SOC_40_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T2_UND_SOC_50_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T2_UND_SOC_60_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T2_UND_SOC_70_WERT Ohm - unsigned int - - 1 - 0 -

RES_0X6353

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_RI_ENTLADEN_FUER_T3_UND_SOC_30_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T3_UND_SOC_40_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T3_UND_SOC_50_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T3_UND_SOC_60_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T3_UND_SOC_70_WERT Ohm - unsigned int - - 1 - 0 -

RES_0X6354

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_RI_ENTLADEN_FUER_T4_UND_SOC_30_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T4_UND_SOC_40_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T4_UND_SOC_50_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T4_UND_SOC_60_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T4_UND_SOC_70_WERT Ohm - unsigned int - - 1 - 0 -

RES_0X6355

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_RI_ENTLADEN_FUER_T5_UND_SOC_30_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T5_UND_SOC_40_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T5_UND_SOC_50_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T5_UND_SOC_60_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T5_UND_SOC_70_WERT Ohm - unsigned int - - 1 - 0 -

RES_0X6356

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_RI_ENTLADEN_FUER_T6_UND_SOC_30_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T6_UND_SOC_40_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T6_UND_SOC_50_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T6_UND_SOC_60_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T6_UND_SOC_70_WERT Ohm - unsigned int - - 1 - 0 -

RES_0X6357

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_RI_ENTLADEN_FUER_T7_UND_SOC_30_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T7_UND_SOC_40_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T7_UND_SOC_50_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T7_UND_SOC_60_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_ENTLADEN_FUER_T7_UND_SOC_70_WERT Ohm - unsigned int - - 1 - 0 -

RES_0X6358

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_RI_LADEN_FUER_T1_UND_SOC_30_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T1_UND_SOC_40_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T1_UND_SOC_50_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T1_UND_SOC_60_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T1_UND_SOC_70_WERT Ohm - unsigned int - - 1 - 0 -

RES_0X6359

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_RI_LADEN_FUER_T2_UND_SOC_30_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T2_UND_SOC_40_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T2_UND_SOC_50_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T2_UND_SOC_60_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T2_UND_SOC_70_WERT Ohm - unsigned int - - 1 - 0 -

RES_0X635A

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_RI_LADEN_FUER_T3_UND_SOC_30_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T3_UND_SOC_40_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T3_UND_SOC_50_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T3_UND_SOC_60_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T3_UND_SOC_70_WERT Ohm - unsigned int - - 1 - 0 -

RES_0X635B

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_RI_LADEN_FUER_T4_UND_SOC_30_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T4_UND_SOC_40_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T4_UND_SOC_50_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T4_UND_SOC_60_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T4_UND_SOC_70_WERT Ohm - unsigned int - - 1 - 0 -

RES_0X635C

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_RI_LADEN_FUER_T5_UND_SOC_30_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T5_UND_SOC_40_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T5_UND_SOC_50_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T5_UND_SOC_60_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T5_UND_SOC_70_WERT Ohm - unsigned int - - 1 - 0 -

RES_0X635D

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_RI_LADEN_FUER_T6_UND_SOC_30_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T6_UND_SOC_40_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T6_UND_SOC_50_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T6_UND_SOC_60_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T6_UND_SOC_70_WERT Ohm - unsigned int - - 1 - 0 -

RES_0X635E

Dimensions: 5 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_RI_LADEN_FUER_T7_UND_SOC_30_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T7_UND_SOC_40_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T7_UND_SOC_50_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T7_UND_SOC_60_WERT Ohm - unsigned int - - 1 - 0 -
STAT_RI_LADEN_FUER_T7_UND_SOC_70_WERT Ohm - unsigned int - - 1 - 0 -

RES_0X6370

Dimensions: 14 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_NV_HVB_SOC_Fahrb_0_20_WERT - - unsigned char - - 1 - 0 -
STAT_NV_HVB_SOC_Fahrb_20_25_WERT - - unsigned char - - 1 - 0 -
STAT_NV_HVB_SOC_Fahrb_25_30_WERT - - unsigned char - - 1 - 0 -
STAT_NV_HVB_SOC_Fahrb_30_33_WERT - - unsigned char - - 1 - 0 -
STAT_NV_HVB_SOC_Fahrb_33_36_WERT - - unsigned char - - 1 - 0 -
STAT_NV_HVB_SOC_Fahrb_36_39_WERT - - unsigned char - - 1 - 0 -
STAT_NV_HVB_SOC_Fahrb_39_42_WERT - - unsigned char - - 1 - 0 -
STAT_NV_HVB_SOC_Fahrb_42_45_WERT - - unsigned char - - 1 - 0 -
STAT_NV_HVB_SOC_Fahrb_45_48_WERT - - unsigned char - - 1 - 0 -
STAT_NV_HVB_SOC_Fahrb_48_51_WERT - - unsigned char - - 1 - 0 -
STAT_NV_HVB_SOC_Fahrb_51_56_WERT - - unsigned char - - 1 - 0 -
STAT_NV_HVB_SOC_Fahrb_56_65_WERT - - unsigned char - - 1 - 0 -
STAT_NV_HVB_SOC_Fahrb_65_80_WERT - - unsigned char - - 1 - 0 -
STAT_NV_HVB_SOC_Fahrb_80_100_WERT - - unsigned char - - 1 - 0 -

RES_0X6371

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_0_Hub_0_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_0_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_0_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_0_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_0_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_0_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_0_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_0_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_0_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_0_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_0_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_0_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6372

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_0_Hub_5_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_5_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_5_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_5_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_5_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_5_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_5_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_5_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_5_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_5_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_5_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_5_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6373

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_0_Hub_10_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_10_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_10_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_10_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_10_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_10_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_10_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_10_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_10_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_10_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_10_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_Hub_10_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6374

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_0_HUB_15_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_15_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_15_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_15_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_15_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_15_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6375

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_0_HUB_25_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_25_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_25_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_25_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_25_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_25_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6376

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_0_HUB_35_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_35_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_35_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_35_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_35_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_35_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6377

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_0_HUB_50_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_50_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_50_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_50_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_50_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_0_HUB_50_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6378

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_20_HUB_0_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_0_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_0_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_0_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_0_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_0_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_0_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_0_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_0_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_0_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_0_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_0_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6379

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_20_HUB_5_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_5_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_5_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_5_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_5_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_5_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_5_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_5_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_5_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_5_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_5_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_5_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X637A

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_20_HUB_10_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_10_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_10_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_10_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_10_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_10_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_10_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_10_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_10_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_10_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_10_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_10_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X637B

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_20_HUB_15_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_15_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_15_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_15_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_15_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_15_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_15_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_15_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_15_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_15_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_15_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_15_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X637C

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_20_HUB_25_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_25_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_25_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_25_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_25_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_25_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X637D

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_20_HUB_35_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_35_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_35_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_35_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_35_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_35_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X637E

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_20_HUB_50_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_50_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_50_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_50_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_50_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_20_HUB_50_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X637F

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_25_HUB_0_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_0_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_0_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_0_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_0_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_0_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_0_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_0_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_0_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_0_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_0_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_0_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6380

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_25_HUB_5_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_5_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_5_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_5_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_5_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_5_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_5_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_5_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_5_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_5_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_5_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_5_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6381

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_25_HUB_10_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_10_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_10_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_10_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_10_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_10_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_10_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_10_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_10_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_10_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_10_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_10_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6382

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_25_HUB_15_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_15_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_15_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_15_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_15_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_15_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_15_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_15_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_15_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_15_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_15_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_15_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6383

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_25_HUB_25_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_25_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_25_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_25_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_25_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_25_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_25_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_25_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_25_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_25_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_25_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_25_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6384

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_25_HUB_35_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_35_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_35_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_35_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_35_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_35_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6385

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_25_HUB_50_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_50_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_50_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_50_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_50_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_25_HUB_50_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6386

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_30_HUB_0_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_0_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_0_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_0_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_0_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_0_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_0_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_0_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_0_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_0_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_0_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_0_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6387

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_30_HUB_5_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_5_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_5_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_5_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_5_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_5_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_5_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_5_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_5_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_5_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_5_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_5_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6388

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_30_HUB_10_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_10_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_10_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_10_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_10_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_10_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_10_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_10_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_10_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_10_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_10_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_10_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6389

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_30_HUB_15_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_15_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_15_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_15_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_15_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_15_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_15_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_15_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_15_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_15_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_15_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_15_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X638A

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_30_HUB_25_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_25_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_25_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_25_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_25_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_25_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_25_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_25_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_25_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_25_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_25_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_25_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X638B

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_30_HUB_35_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_35_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_35_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_35_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_35_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_35_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_35_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_35_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_35_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_35_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_35_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_35_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X638C

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_30_HUB_50_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_50_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_50_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_50_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_50_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_30_HUB_50_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X638D

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_50_HUB_0_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_0_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_0_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_0_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_0_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_0_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_0_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_0_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_0_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_0_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_0_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_0_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X638E

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_50_HUB_5_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_5_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_5_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_5_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_5_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_5_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_5_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_5_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_5_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_5_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_5_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_5_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X638F

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_50_HUB_10_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_10_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_10_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_10_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_10_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_10_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_10_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_10_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_10_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_10_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_10_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_10_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6390

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_50_HUB_15_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_15_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_15_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_15_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_15_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_15_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_15_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_15_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_15_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_15_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_15_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_15_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6391

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_50_HUB_25_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_25_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_25_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_25_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_25_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_25_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_25_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_25_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_25_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_25_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_25_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_25_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6392

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_50_HUB_35_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_35_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_35_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_35_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_35_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_35_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_35_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_35_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_35_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_35_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_35_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_35_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6393

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_50_HUB_50_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_50_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_50_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_50_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_50_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_50_HUB_50_EL_I_10_WERT - - unsigned long - - 1 - 0 -

RES_0X6394

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_70_HUB_0_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_0_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_0_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_0_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_0_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_0_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_0_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_0_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_0_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_0_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_0_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_0_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6395

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_70_HUB_5_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_5_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_5_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_5_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_5_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_5_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_5_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_5_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_5_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_5_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_5_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_5_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6396

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_70_HUB_10_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_10_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_10_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_10_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_10_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_10_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_10_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_10_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_10_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_10_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_10_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_10_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6397

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_70_HUB_15_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_15_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_15_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_15_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_15_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_15_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_15_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_15_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_15_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_15_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_15_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_15_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6398

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_70_HUB_25_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_25_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_25_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_25_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_25_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_25_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_25_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_25_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_25_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_25_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_25_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_25_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X6399

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_70_HUB_35_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_35_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_35_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_35_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_35_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_35_EL_I_10_WERT - - unsigned long - - 1 - 0 -

RES_0X639A

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_70_HUB_50_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_50_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_50_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_50_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_50_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_70_HUB_50_EL_I_10_WERT - - unsigned long - - 1 - 0 -

RES_0X639B

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_80_HUB_0_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_0_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_0_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_0_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_0_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_0_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_0_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_0_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_0_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_0_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_0_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_0_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X639C

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_80_HUB_5_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_5_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_5_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_5_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_5_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_5_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_5_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_5_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_5_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_5_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_5_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_5_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X639D

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_80_HUB_10_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_10_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_10_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_10_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_10_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_10_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_10_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_10_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_10_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_10_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_10_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_10_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X639E

Dimensions: 12 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_80_HUB_15_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_15_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_15_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_15_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_15_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_15_EL_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_15_L_I_0_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_15_L_I_10_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_15_L_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_15_L_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_15_L_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_15_L_I_160_WERT - - unsigned long - - 1 - 0 -

RES_0X639F

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_80_HUB_25_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_25_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_25_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_25_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_25_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_25_EL_I_10_WERT - - unsigned long - - 1 - 0 -

RES_0X63A0

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_80_HUB_35_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_35_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_35_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_35_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_35_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_35_EL_I_10_WERT - - unsigned long - - 1 - 0 -

RES_0X63A1

Dimensions: 6 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_SOC_HV_BATT_STARTSOC_80_HUB_50_EL_I_200_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_50_EL_I_160_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_50_EL_I_120_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_50_EL_I_80_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_50_EL_I_40_WERT - - unsigned long - - 1 - 0 -
STAT_SOC_HV_BATT_STARTSOC_80_HUB_50_EL_I_10_WERT - - unsigned long - - 1 - 0 -

RES_0X63A2

Dimensions: 4 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_KALTSTARTTEMP1_WERT - - unsigned long - - 1 - 0 -
STAT_KALTSTARTTEMP2_WERT - - unsigned long - - 1 - 0 -
STAT_KALTSTARTTEMP3_WERT - - unsigned long - - 1 - 0 -
STAT_KALTSTARTTEMP4_WERT - - unsigned long - - 1 - 0 -

RES_0X63A4

Dimensions: 3 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_NLM_ERREAKT_WERT - - unsigned long - - 1 - 0 -
STAT_NLM_DEAK_MSA_WERT - - unsigned char - - 1 - 0 -
STAT_ANF_NL_EME_WERT - - unsigned char - - 1 - 0 -

RES_0X63A5

Dimensions: 40 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ZEIT_START_CCM_636_0_WERT sec - unsigned long - - 1 - 0 -
STAT_ZEIT_STOP_CCM_636_0_WERT sec - unsigned long - - 1 - 0 -
STAT_KM_START_CCM_636_0_WERT km - unsigned long - - 1 - 0 -
STAT_ABBRUCHBEDINGUNG_0_WERT - - unsigned long - - 1 - 0 -
STAT_ZEIT_START_CCM_636_1_WERT sec - unsigned long - - 1 - 0 -
STAT_ZEIT_STOP_CCM_636_1_WERT sec - unsigned long - - 1 - 0 -
STAT_KM_START_CCM_636_1_WERT km - unsigned long - - 1 - 0 -
STAT_ABBRUCHBEDINGUNG_1_WERT - - unsigned long - - 1 - 0 -
STAT_ZEIT_START_CCM_636_2_WERT sec - unsigned long - - 1 - 0 -
STAT_ZEIT_STOP_CCM_636_2_WERT sec - unsigned long - - 1 - 0 -
STAT_KM_START_CCM_636_2_WERT km - unsigned long - - 1 - 0 -
STAT_ABBRUCHBEDINGUNG_2_WERT - - unsigned long - - 1 - 0 -
STAT_ZEIT_START_CCM_636_3_WERT sec - unsigned long - - 1 - 0 -
STAT_ZEIT_STOP_CCM_636_3_WERT sec - unsigned long - - 1 - 0 -
STAT_KM_START_CCM_636_3_WERT km - unsigned long - - 1 - 0 -
STAT_ABBRUCHBEDINGUNG_3_WERT - - unsigned long - - 1 - 0 -
STAT_ZEIT_START_CCM_636_4_WERT sec - unsigned long - - 1 - 0 -
STAT_ZEIT_STOP_CCM_636_4_WERT sec - unsigned long - - 1 - 0 -
STAT_KM_START_CCM_636_4_WERT km - unsigned long - - 1 - 0 -
STAT_ABBRUCHBEDINGUNG_4_WERT - - unsigned long - - 1 - 0 -
STAT_ZEIT_START_CCM_636_5_WERT sec - unsigned long - - 1 - 0 -
STAT_ZEIT_STOP_CCM_636_5_WERT sec - unsigned long - - 1 - 0 -
STAT_KM_START_CCM_636_5_WERT km - unsigned long - - 1 - 0 -
STAT_ABBRUCHBEDINGUNG_5_WERT - - unsigned long - - 1 - 0 -
STAT_ZEIT_START_CCM_636_6_WERT sec - unsigned long - - 1 - 0 -
STAT_ZEIT_STOP_CCM_636_6_WERT sec - unsigned long - - 1 - 0 -
STAT_KM_START_CCM_636_6_WERT km - unsigned long - - 1 - 0 -
STAT_ABBRUCHBEDINGUNG_6_WERT - - unsigned long - - 1 - 0 -
STAT_ZEIT_START_CCM_636_7_WERT sec - unsigned long - - 1 - 0 -
STAT_ZEIT_STOP_CCM_636_7_WERT sec - unsigned long - - 1 - 0 -
STAT_KM_START_CCM_636_7_WERT km - unsigned long - - 1 - 0 -
STAT_ABBRUCHBEDINGUNG_7_WERT - - unsigned long - - 1 - 0 -
STAT_ZEIT_START_CCM_636_8_WERT sec - unsigned long - - 1 - 0 -
STAT_ZEIT_STOP_CCM_636_8_WERT sec - unsigned long - - 1 - 0 -
STAT_KM_START_CCM_636_8_WERT km - unsigned long - - 1 - 0 -
STAT_ABBRUCHBEDINGUNG_8_WERT - - unsigned long - - 1 - 0 -
STAT_ZEIT_START_CCM_636_9_WERT sec - unsigned long - - 1 - 0 -
STAT_ZEIT_STOP_CCM_636_9_WERT sec - unsigned long - - 1 - 0 -
STAT_KM_START_CCM_636_9_WERT km - unsigned long - - 1 - 0 -
STAT_ABBRUCHBEDINGUNG_9_WERT - - unsigned long - - 1 - 0 -

SG_FUNKTIONEN

Dimensions: 129 rows × 16 columns

ARG ID RESULTNAME INFO EINHEIT LABEL L/H DATENTYP NAME MUL DIV ADD SG_ADR SERVICE ARG_TABELLE RES_TABELLE
STATUS_EPSOFFSET 0x6300 STAT_EPSOFF_WERT EPS Offset -180,00° .. +180,00° ° GETEPSOFFSET high int - 180 32768 - 0x1A 22 - -
STATUS_TEMPERATUREN 0x6301 - Temperaturen lesen vom E-Motor DCB (Endstufen) Control Board - GETINVERTERTEMPERATURES - - - - - - 0x1A 22 - RES_0x6301
STATUS_HVIL_GESAMT 0x6302 STAT_HVIL_GESAMT_NR Auslesen des HVIL-Zustandes falls HVIL unterbrochen, dann n.i.O. 0-n B_err_interlk - unsigned char TAB_STAT_HVIL_GESAMT_NR - - - 0x1A 22 - -
STATUS_HV_ISOLATION 0x6303 STAT_HV_ISOLATION_NR Auslesen des Isolationswächters falls Iso-Fehler, dann n.i.O. 0-n B_extiso_sm - unsigned char TAB_STAT_HV_ISOLATION_NR - - - 0x1A 22 - -
STATUS_PRECHARGE 0x6304 STAT_PRECHARGE_NR Variable in der Basis SW: ECUM_eSystemState= Run -> Precharge abgeschlossen. Den Precharge macht aber die SME 0-n ECUM_eSystemState - unsigned char TAB_STAT_PRECHARGE_NR - - - 0x1A 22 - -
STATUS_SPANNUNG_DC_HV 0x6305 STAT_SPANNUNG_DC_HV_WERT DC Spannung der EMK EMR (HV-Batterieseitig ) (nach intern) V U_dc_hv_le_ist - unsigned int - 0.25 - 0 0x1A 22 - -
STATUS_HV_STROM 0x6306 - HV-Strom Bordnetz - T_ecu_em1 - - - - - - 0x1A 22 - RES_0x6306
STATUS_POSITIONSGEBER 0x6307 STAT_POSITIONSGEBER_WERT Winkelstellung der E-Maschinen in Grad ° T_em1 - int - 180 32768 0 0x1A 22 - -
STATUS_LV_BAT 0x6308 - - - - - - - - - - 0x1A 22 - RES_0x6308
STATUS_ELEKTRISCHE_MASCHINE 0x6309 - - - - - - - - - - 0x1A 22 - RES_0x6309
STATUS_DCDC_LADEMODUS 0x630A - - - - - - - - - - 0x1A 22 - RES_0x630A
STATUS_EME_ANTRIEBSART 0x630B - Auswahl: normal, explizit keine E-Maschinen unterstützung positive Momentengrenzen auf Null setzen, Md_em1_max_1s/10s_pm. Umsetzung in der Funktion P_emko_emlim - - - - - - - - 0x1A 22;2E ARG_0x630B RES_0x630B
STATUS_KL30C_SPANNUNG 0x6310 - - - - - - - - - - 0x1A 22 - RES_0x6310
STATUS_PUMPEN 0x630D STAT_EME_PUMPE_DREHZAHL_WERT - U/min N_colpp_eme_ly - unsigned int - 1 1 0 0x1A 22 - -
STATUS_TEMPERATUR_HVB 0x6313 STAT_TEMPERATUR_HVB_WERT - °C T_hvb_plaus - signed long - 1 1 0 0x1A 22 - -
STATUS_TEMP_DCDC 0x6314 - - - - - - - - 1 - 0x1A 22 - RES_0x6314
STATUS_SPANNUNG_DC_HV_DCDC 0x6315 STAT_SPANNUNG_DC_HV_DCDC_WERT - V U_dcdc1_hv_ly - unsigned int - 0.1 - 0 0x1A 22 - -
STATUS_EMK_STROM_DC 0x6316 - - - - - - - - 1 - 0x1A 22 - RES_0x6316
STATUS_DCDC_LV 0x6317 STAT_STROM_DCDC_LV_WERT - A I_dcdc1_lv_ly - signed int - 1 - 0 0x1A 22 - -
STATUS_EPI 0x6318 - - - - - - - - - - 0x1A 22 - RES_0x6318
STATUS_ERSTSTARTBEGRENZUNG 0x6319 STAT_ERSTSTARTBEGRAKTIV_WERT - - ACAL_ErststartBegrAktiv - unsigned int - 1 - 0 0x1A 22 - -
STATUS_INFO_EMK 0x631A STAT_INFO_EMK_WERT - - St_info_em1 - unsigned int - 1 - 0 0x1A 22 - -
STATUS_HVPM_DC/DC_ANSTEUERUNG 0x6320 - - - - - - - - - - 0x1A 22 - RES_0x6320
STATUS_HVPM_VERBRAUCHERREDUZIERUNG 0x6321 - - - - - - - - - - 0x1A 22 - RES_0x6321
STATUS_HVPM_HV_SYSTEM_ON_OFF 0x6322 - - - - - - - - 1 - 0x1A 22 - RES_0x6322
STATUS_HVPM_ENERGIEBORDNETZ 0x6323 - - - - - - - - 1 - 0x1A 22 - RES_0x6323
STATUS_HVPM_MSA 0x6324 - - - - - - - - - - 0x1A 22 - RES_0x6324
STATUS_HVPM_PKOR 0x6325 - - - - - - - - - - 0x1A 22 - RES_0x6325
STATUS_REFERENZKAPAZITAET_HVB 0x6326 STAT_REF_KAPAZITAET_HVB_WERT - As NV_SOH_CAP_REFERENCE - unsigned int - 1 - 0 0x1A 22 - -
STATUS_SOC_HVB 0x6327 STAT_SOC_HVB_WERT - % Soc_hvb_ist_ly - unsigned int - 0.1 - 0 0x1A 22 - -
STATUS_RUHESPANNUNG 0x632A STAT_OCV - 0/1 B_ocv_ist - unsigned char - 1 - 0 0x1A 22 - -
STATUS_ESOC_SOC 0x632B STAT_ESOC_SOC_TABLE_OUT_WERT - % Soc_ocv_table_out_ist - signed long - 1 - 0 0x1A 22 - -
STATUS_LADUNGSMENGE_HVB 0x632C STAT_AKTUELLE_LADUNGSMENGE_HVB_WERT - As NV_SOH_Q_SUM_TESTER - signed long - 1 - 0 0x1A 22 - -
STATUS_HVB_TAUSCH_LESEN 0x632D - - - - - - - - - - 0x1A 22 - RES_0x632D
STATUS_HVB_LADUNGSMENGE 0x632E - - - - - - - - - - 0x1A 22 - RES_0x632E
STATUS_LADUNG_HV_BATTERIE 0x6332 STAT_LADUNG_HV_BATTERIE_WERT - Ah Count_Ah_chg_lifetime - signed long - 1 - 0 0x1A 22 - -
STATUS_ENTLADUNG_HV_BATTERIE 0x6333 STAT_ENTLADUNG_HV_BATTERIE_WERT - Ah Count_Ah_dchg_lifetime - signed long - 1 - 0 0x1A 22 - -
STATUS_ALTERUNG_INNENWIDERSTAND 0x6334 STAT_ALTERUNG_INNENWIDERSTAND_WERT - % NV_SOH_INNENWIDERSTAND - signed long - 1 - 0 0x1A 22 - -
STATUS_ALTERUNG_KAPAZITAET 0x6335 STAT_ALTERUNG_KAPAZITAET_WERT - % NV_SOH_KAPAZITAET - signed long - 1 - 0 0x1A 22 - -
STATUS_HVB_WARRANTY 0x6336 - - - - - - - - - - 0x1A 22 - RES_0x6336
STATUS_ENTLADE_INNENWIDERSTAND_T1 0x6351 - - - - - - - - - - 0x1A 22 - RES_0x6351
STATUS_ENTLADE_INNENWIDERSTAND_T2 0x6352 - - - - - - - - - - 0x1A 22 - RES_0x6352
STATUS_ENTLADE_INNENWIDERSTAND_T3 0x6353 - - - - - - - - - - 0x1A 22 - RES_0x6353
STATUS_ENTLADE_INNENWIDERSTAND_T4 0x6354 - - - - - - - - - - 0x1A 22 - RES_0x6354
STATUS_ENTLADE_INNENWIDERSTAND_T5 0x6355 - - - - - - - - - - 0x1A 22 - RES_0x6355
STATUS_ENTLADE_INNENWIDERSTAND_T6 0x6356 - - - - - - - - - - 0x1A 22 - RES_0x6356
STATUS_ENTLADE_INNENWIDERSTAND_T7 0x6357 - - - - - - - - - - 0x1A 22 - RES_0x6357
STATUS_LADE_INNENWIDERSTAND_T1 0x6358 - - - - - - - - - - 0x1A 22 - RES_0x6358
STATUS_LADE_INNENWIDERSTAND_T2 0x6359 - - - - - - - - - - 0x1A 22 - RES_0x6359
STATUS_LADE_INNENWIDERSTAND_T3 0x635A - - - - - - - - - - 0x1A 22 - RES_0x635A
STATUS_LADE_INNENWIDERSTAND_T4 0x635B - - - - - - - - - - 0x1A 22 - RES_0x635B
STATUS_LADE_INNENWIDERSTAND_T5 0x635C - - - - - - - - - - 0x1A 22 - RES_0x635C
STATUS_LADE_INNENWIDERSTAND_T6 0x635D - - - - - - - - - - 0x1A 22 - RES_0x635D
STATUS_LADE_INNENWIDERSTAND_T7 0x635E - - - - - - - - - - 0x1A 22 - RES_0x635E
STATUS_MITTELWERT_RI_FAKTOR_1S 0x635F STAT_MITTELWERT_FUER_RI_FAKTOR_1S_WERT - Ohm NV_SOH_RI_CORR_FCTR_LT - unsigned int - 1 - 0 0x1A 22 - -
STATUS_MITTELWERT_RI_FAKTOR_5S 0x6360 STAT_MITTELWERT_FUER_RI_FAKTOR_5S_WERT - Ohm NV_SOH_RI_CORR_FCTR_ST - unsigned int - 1 - 0 0x1A 22 - -
STATUS_ANZEIGE_SOC 0x6361 STAT_ANZEIGE_SOC_WERT - % NV_ANZ_SOC - unsigned int - 1 - 0 0x1A 22 - -
STATUS_HVB_HISTORIE_STROMBELASTUNG 0x636D - - - - - - - - - - 0x1A 22 - RES_0x636D
STATUS_HVB_HISTORIE_TEMPERATUR 0x636E - - - - - - - - - - 0x1A 22 - RES_0x636E
STATUS_HVB_HISTORIE_SOC_SEIT_EINBAU 0x636F - - - - - - - - - - 0x1A 22 - RES_0x636F
STATUS_HVB_SOC_FAHRB 0x6370 - - - - - - - - - - 0x1A 22 - RES_0x6370
STATUS_HVBHIST_STARTSOC_0_HUB_0 0x6371 - - - - - - - - - - 0x1A 22 - RES_0x6371
STATUS_HVBHIST_STARTSOC_0_HUB_5 0x6372 - - - - - - - - - - 0x1A 22 - RES_0x6372
STATUS_HVBHIST_STARTSOC_0_HUB_10 0x6373 - - - - - - - - - - 0x1A 22 - RES_0x6373
STATUS_HVBHIST_STARTSOC_0_HUB_15_ L 0x6374 - - - - - - - - - - 0x1A 22 - RES_0x6374
STATUS_HVBHIST_STARTSOC_0_HUB_25_ L 0x6375 - - - - - - - - - - 0x1A 22 - RES_0x6375
STATUS_HVBHIST_STARTSOC_0_HUB_35_ L 0x6376 - - - - - - - - - - 0x1A 22 - RES_0x6376
STATUS_HVBHIST_STARTSOC_0_HUB_50_ L 0x6377 - - - - - - - - - - 0x1A 22 - RES_0x6377
STATUS_HVBHIST_STARTSOC_20_HUB_0 0x6378 - - - - - - - - - - 0x1A 22 - RES_0x6378
STATUS_HVBHIST_STARTSOC_20_HUB_5 0x6379 - - - - - - - - - - 0x1A 22 - RES_0x6379
STATUS_HVBHIST_STARTSOC_20_HUB_10 0x637A - - - - - - - - - - 0x1A 22 - RES_0x637A
STATUS_HVBHIST_STARTSOC_20_HUB_15 0x637B - - - - - - - - - - 0x1A 22 - RES_0x637B
STATUS_HVBHIST_STARTSOC_20_HUB_25_L 0x637C - - - - - - - - - - 0x1A 22 - RES_0x637C
STATUS_HVBHIST_STARTSOC_20_HUB_35_L 0x637D - - - - - - - - - - 0x1A 22 - RES_0x637D
STATUS_HVBHIST_STARTSOC_20_HUB_50_L 0x637E - - - - - - - - - - 0x1A 22 - RES_0x637E
STATUS_HVBHIST_STARTSOC_25_HUB_0 0x637F - - - - - - - - - - 0x1A 22 - RES_0x637F
STATUS_HVBHIST_STARTSOC_25_HUB_5 0x6380 - - - - - - - - - - 0x1A 22 - RES_0x6380
STATUS_HVBHIST_STARTSOC_25_HUB_10 0x6381 - - - - - - - - - - 0x1A 22 - RES_0x6381
STATUS_HVBHIST_STARTSOC_25_HUB_15 0x6382 - - - - - - - - - - 0x1A 22 - RES_0x6382
STATUS_HVBHIST_STARTSOC_25_HUB_25 0x6383 - - - - - - - - - - 0x1A 22 - RES_0x6383
STATUS_HVBHIST_STARTSOC_25_HUB_35_L 0x6384 - - - - - - - - - - 0x1A 22 - RES_0x6384
STATUS_HVBHIST_STARTSOC_25_HUB_50_L 0x6385 - - - - - - - - - - 0x1A 22 - RES_0x6385
STATUS_HVBHIST_STARTSOC_30_HUB_0 0x6386 - - - - - - - - - - 0x1A 22 - RES_0x6386
STATUS_HVBHIST_STARTSOC_30_HUB_5 0x6387 - - - - - - - - - - 0x1A 22 - RES_0x6387
STATUS_HVBHIST_STARTSOC_30_HUB_10 0x6388 - - - - - - - - - - 0x1A 22 - RES_0x6388
STATUS_HVBHIST_STARTSOC_30_HUB_15 0x6389 - - - - - - - - - - 0x1A 22 - RES_0x6389
STATUS_HVBHIST_STARTSOC_30_HUB_25 0x638A - - - - - - - - - - 0x1A 22 - RES_0x638A
STATUS_HVBHIST_STARTSOC_30_HUB_35 0x638B - - - - - - - - - - 0x1A 22 - RES_0x638B
STATUS_HVBHIST_STARTSOC_30_HUB_50_L 0x638C - - - - - - - - - - 0x1A 22 - RES_0x638C
STATUS_HVBHIST_STARTSOC_50_HUB_0 0x638D - - - - - - - - - - 0x1A 22 - RES_0x638D
STATUS_HVBHIST_STARTSOC_50_HUB_5 0x638E - - - - - - - - - - 0x1A 22 - RES_0x638E
STATUS_HVBHIST_STARTSOC_50_HUB_10 0x638F - - - - - - - - - - 0x1A 22 - RES_0x638F
STATUS_HVBHIST_STARTSOC_50_HUB_15 0x6390 - - - - - - - - - - 0x1A 22 - RES_0x6390
STATUS_HVBHIST_STARTSOC_50_HUB_25 0x6391 - - - - - - - - - - 0x1A 22 - RES_0x6391
STATUS_HVBHIST_STARTSOC_50_HUB_35 0x6392 - - - - - - - - - - 0x1A 22 - RES_0x6392
STATUS_HVBHIST_STARTSOC_50_HUB_50_EL 0x6393 - - - - - - - - - - 0x1A 22 - RES_0x6393
STATUS_HVBHIST_STARTSOC_70_HUB_0 0x6394 - - - - - - - - - - 0x1A 22 - RES_0x6394
STATUS_HVBHIST_STARTSOC_70_HUB_5 0x6395 - - - - - - - - - - 0x1A 22 - RES_0x6395
STATUS_HVBHIST_STARTSOC_70_HUB_10 0x6396 - - - - - - - - - - 0x1A 22 - RES_0x6396
STATUS_HVBHIST_STARTSOC_70_HUB_15 0x6397 - - - - - - - - - - 0x1A 22 - RES_0x6397
STATUS_HVBHIST_STARTSOC_70_HUB_25 0x6398 - - - - - - - - - - 0x1A 22 - RES_0x6398
STATUS_HVBHIST_STARTSOC_70_HUB_35_EL 0x6399 - - - - - - - - - - 0x1A 22 - RES_0x6399
STATUS_HVBHIST_STARTSOC_70_HUB_50_EL 0x639A - - - - - - - - - - 0x1A 22 - RES_0x639A
STATUS_HVBHIST_STARTSOC_80_HUB_0 0x639B - - - - - - - - - - 0x1A 22 - RES_0x639B
STATUS_HVBHIST_STARTSOC_80_HUB_5 0x639C - - - - - - - - - - 0x1A 22 - RES_0x639C
STATUS_HVBHIST_STARTSOC_80_HUB_10 0x639D - - - - - - - - - - 0x1A 22 - RES_0x639D
STATUS_HVBHIST_STARTSOC_80_HUB_15 0x639E - - - - - - - - - - 0x1A 22 - RES_0x639E
STATUS_HVBHIST_STARTSOC_80_HUB_25_EL 0x639F - - - - - - - - - - 0x1A 22 - RES_0x639F
STATUS_HVBHIST_STARTSOC_80_HUB_35_EL 0x63A0 - - - - - - - - - - 0x1A 22 - RES_0x63A0
STATUS_HVBHIST_STARTSOC_80_HUB_50_EL 0x63A1 - - - - - - - - - - 0x1A 22 - RES_0x63A1
STATUS_KALTSTARTZAEHLER 0x63A2 - - - - - - - - - - 0x1A 22 - RES_0x63A2
STATUS_BETRIEBSART_HYBRID 0x63A3 STAT_BA_HYBRID_WERT - - Ba_hybrid - unsigned char - 1 - 0 0x1A 22 - -
STATUS_NLK_ER_ANF 0x63A4 - - - - - - - - - - 0x1A 22 - RES_0x63A4
STATUS_HVPM_SPANNUNGSFREIHEIT 0x63A5 - - - - - - - - - - 0x1A 22 - RES_0x63A5
STEUERN_ROTORLAGESENSOR_ANLERNEN 0xF500 - - - - - - - - - - 0x1A 31 ARG_0xF500 RES_0xF500
STEUERN_DCDC_WANDLER 0xF502 - RIDI_DCDC - Steuern der HV-Spannung des DC/DC-Wandlers - - - - - - - - 0x1A 31 ARG_0xF502 RES_0xF502
STEUERN_HV_SYSTEM_ON_OFF 0xF503 - RIDI_HYSYS - Hoch-/Runterfahren HV-System - - - - - - - - 0x1A 31 ARG_0xF503 RES_0xF503
STEUERN_EME_PUMPE 0xF504 - RIDI_EMECWP5 - Vorgabe der Drehzahl Kühlwasserpumpe für die EME - - - - - - - - 0x1A 31 ARG_0xF504 RES_0xF504
STEUERN_DME_LEERLAUFREGELUNG_AKTIVIEREN 0xF505 - RIDI_DMELLR - Leerlaufregler der DME aktivieren - - - - - - - - 0x1A 2E ARG_0xF505 -
STEUERN_ELEKTRISCHE_MASCHINE_GENERATORBETRIEB 0xF506 - RIDI_EMGENERATOR negative Momentengrenzen auf Null setzen, Md_em1_min_1s/10s_pm. Umsetzung in der Funktion P_emko_emlim - - - - - - - - 0x1A 2E ARG_0xF506 -
STEUERN_HVPM_INFOSPEICHER_STRZLR_LOESCHEN 0xF507 - RIDI_HVPM_STRZLR_CLR - Löschen Infospeicher HSPM - - - - - - - - 0x1A 2E ARG_0xF507 -
STEUERN_HVPM_INFOSPEICHER_SPMON_LOESCHEN 0xF508 - RIDI_HVPM_SPMON_CLR - Löschen Infospeicher HVPM - - - - - - - - 0x1A 2E ARG_0xF508 -
STEUERN_ENTLADEMODUS 0xF509 - RIDI_ENTLADEMODUS - Schütze müssen geschlossen sein und Temperatur der Batterie über 10°C und KL15 On Kein Gang - - - - - - - - 0x1A 31 ARG_0xF509 RES_0xF509
STEUERN_LADEMODUS 0xF50A - RIDI_LADEMODUS - Schütze müssen geschlossen sein und Temperatur der Batterie über 10°C und KL15 On Kein Gang - - - - - - - - 0x1A 31 ARG_0xF50A RES_0xF50A
STEUERN_REFERENZKAPAZITAET_HVB 0xF50B - RIDI_REFKAP_HVB - Die auf dem Tester ermittelte Referenzkapazität wird auf die EME geschrieben - - - - - - - - 0x1A 2E ARG_0xF50B -
STEUERN_ELEKTRISCHE_MASCHINE 0xF50C - RIDI_EMASCHINE - Über STEUERN_ELEKTRISCHE_MASCHINE lassen sich die Betriebsart der E-Maschine (Momenten- oder Drehzahl-Vorgabe) einstellung und das Moment bzw. die Drehzahl vorgeben. Betriebsart = 0 --> Momenten-Vorgabe Md_em1_soll_steuern Betriebsart = 1 --> Drehzahl-Vorgabe N_em1_soll_steuern - - - - - - - - 0x1A 31 ARG_0xF50C -
STEUERN_HVPM_INFOSPEICHER_MSA_LOESCHEN 0xF50D - RIDI_HVPM_MSA_CLR - Alle Infospeicher aus Job STATUS_HVPM_MSA Null setzen - - - - - - - - 0x1A 2E ARG_0xF50D -
STEUERN_HVPM_INFOSPEICHER_PKOR_LOESCHEN 0xF50E - RIDI_HVPM_PKOR_CLR - Alle Infospeicher aus Job STATUS_HVPM_EKMV Null setzen - - - - - - - - 0x1A 2E ARG_0xF50E -
STEUERN_EEP_RECALL_DEFAULT 0xF50F - Zurücksetzen der ZFS-EEPROM-Parameter auf Defaultwerte - - - - - - - - 0x1A 31 - -

TAB_STAT_HV_ISOLATION_NR

Dimensions: 3 rows × 2 columns

WERT TEXT
0x00 ok
0x01 nicht ok
0x02 Test nicht möglich

TAB_STAT_PRECHARGE_NR

Dimensions: 2 rows × 2 columns

WERT TEXT
0x00 Zwischenkreis nicht geladen
0x01 Zwischenkreis geladen

TAB_STAT_HVIL_GESAMT_NR

Dimensions: 2 rows × 2 columns

WERT TEXT
0x00 Interlock nicht unterbrochen
0x01 Interlock unterbrochen

TAB_ST_DIAG_DCDC_ANF

Dimensions: 4 rows × 2 columns

WERT TEXT
0 Kontrolle an EME-SW
1 Anforderung Buck-Modus
2 Anforderung Boost-Modus
3 Anforderung Standby-Modus

TAB_ST_B_DIAG_DCDC

Dimensions: 5 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
STAT_B_SOC_DIAG_LAD_LMT - - unsigned char 0x01 - - - - - - 0: Abbruchbedingung EME-SW
STAT_B_I_DIAG_DCDC_LV_OUT 0/1 - unsigned char 0x02 - - - - - - 0: Systemgrenze verwenden
STAT_B_I_DIAG_DCDC_HV_OUT 0/1 - unsigned char 0x04 - - - - - - 0: Systemgrenze verwenden
STAT_B_U_DIAG_DCDC_LV_OUT 0/1 - unsigned char 0x08 - - - - - - 0: Systemgrenze verwenden
STAT_B_U_DIAG_DCDC_HV_OUT 0/1 - unsigned char 0x10 - - - - - - 0: Systemgrenze verwenden

RES_ST_DIAG_DCDC_MODUS

Dimensions: 3 rows × 2 columns

WERT TEXT
0 PENDING
1 SUCCESS
2 FAILURE

RES_ST_DIAG_DCDC_GRENZEN

Dimensions: 2 rows × 2 columns

WERT TEXT
1 SUCCESS
2 FAILURE

TAB_ST_DIAG_HV_ANF

Dimensions: 3 rows × 2 columns

WERT TEXT
0 Kontrolle an EME-SW
1 Hochfahren HV-System angefordert
2 Runterfahren HV-System angefordert

RES_ST_DIAG_HVSTART

Dimensions: 3 rows × 2 columns

WERT TEXT
0 PENDING
1 SUCCESS
2 FAILURE

ARG_EME_ANTRIEBSART

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
ST_EME_ANTRIEBSART - - unsigned char - TAB_ST_EME_ANTRIEBSART 1 1 0 0 1 Ansteuerung EME Antriebsart, keine EM Unterstuetzung

TAB_ST_EME_ANTRIEBSART

Dimensions: 2 rows × 2 columns

WERT TEXT
0 Kontrolle an EME-SW
1 Keine EM-Unterstuetzung

TAB_ST_EM_GENERATOR

Dimensions: 2 rows × 2 columns

WERT TEXT
0 Kontrolle an EME-SW
1 EM Generatorbetrieb

TAB_ST_DME_LLR

Dimensions: 2 rows × 2 columns

WERT TEXT
0 Kontrolle an EME-SW
1 LLR auf DME aktivieren

TAB_STAT_KL50L_NR

Dimensions: 2 rows × 2 columns

WERT TEXT
0 Aus
1 Ein

TAB_STAT_DCDC_LADEMODUS_NR

Dimensions: 4 rows × 2 columns

WERT TEXT
0 Off
1 Buck
2 Boost
3 geregelt

TAB_STAT_EME_ANTRIEBSART_NR

Dimensions: 6 rows × 2 columns

WERT TEXT
0 MSA
1 Boost
2 Boost
3 Rekuperation
4 Batterie Entladen
5 Batterie Laden

TAB_ST_ROTORLAGESENSOR_ANLERNEN

Dimensions: 3 rows × 2 columns

WERT TEXT
0 Spannungskalibrierung
1 Stromkalibrierung
2 EPS-Offsetkalibrierung

RES_0X6312

Dimensions: 2 rows × 10 columns

RESULTNAME EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_INNENWIDERSTAND_WERT - - unsigned int - - - - - Wert des Innenwiderstandes der HV-Batterie
STAT_INNENWIDERSTAND_EINH - - unsigned char - - - - - Einheit des Innenwiderstandes der HV-Batterie

TAB_KL30C_STATUS

Dimensions: 2 rows × 2 columns

WERT TEXT
0 Crash nicht erkannt
1 Crash erkannt

TAB_ROTORLAGE_SENSOR_STATUS

Dimensions: 3 rows × 2 columns

WERT TEXT
70 Die Routine Rotorlagesensor Anlernen wurde fehlerhaft beendet.
73 Die Routine Rotorlagesensor Anlernen wurde gestartet und läuft.
82 Die Routine Rotorlagesensor Anlernen wurde erfolgreich beendet.

TAB_EM_BETRIEBSART

Dimensions: 2 rows × 2 columns

WERT TEXT
0 Momentenvorgabe
1 Drehzahlvorgabe

TAB_HV_SYS_ON_OFF

Dimensions: 4 rows × 2 columns

WERT TEXT
WERT TEXT
0 Keine Anforderung
1 Anforderung HV ein
2 Anforderung HV aus

ARG_0X630B

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
ST_EME_ANTRIEBSART 0-n - unsigned char - TAB_ST_EME_ANTRIEBSART 1 1 - - 1 Ansteuerung EME Antriebsart, keine EM Unterstuetzung

RES_0XF500

Dimensions: 2 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ROTORLAGESENSOR_STATUS_MODE - - + 0-n - unsigned char - TAB_ROTORLAGE_SENSOR_STATUS 1 1 0 Status und Mode
STAT_ROTORLAGESENSOR_WERT - - + ° - int - - 180 32768 0 EPS Offset

ARG_0XF500

Dimensions: 1 rows × 14 columns

ARG STR STPR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
ST_ROTORLAGESENSOR_ANLERNEN + - 0-n - unsigned char - TAB_ST_ROTORLAGESENSOR_ANLERNEN - - - - - -

RES_0XF502

Dimensions: 2 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ST_DIAG_DCDC_MODUS - - + 0-n - unsigned char - RES_ST_DIAG_DCDC_MODUS 1 1 0 Result DCDC-Modus
STAT_ST_DIAG_DCDC_GRENZEN - - + 0-n - unsigned char - RES_ST_DIAG_DCDC_GRENZEN 1 1 0 Result DCDC-Grenzen

ARG_0XF502

Dimensions: 7 rows × 14 columns

ARG STR STPR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
ST_DIAG_DCDC_ANF + - 0-n - unsigned char - TAB_ST_DIAG_DCDC_ANF - - - - - Steuerung der Systemgrenzen
ST_B_DIAG_DCDC_WERT + - - - unsigned char - - - - - - - DCDC Betriebsmodus
SOC_DIAG_LAD_LMT + - % - unsigned int - - 1 1 0 0 100 HV-SOC
I_DIAG_DCDC_LV_OUT + - A - signed int - - 10 1 0 -200 200 I_LV Systemgrenze für Steuerung
I_DIAG_DCDC_HV_OUT + - A - signed int - - 10 1 0 -25 25 I_HV Systemgrenze für Steuerung
U_DIAG_DCDC_LV_OUT + - V - unsigned int - - 10 1 0 0 33 U_LV Systemgrenze für Steuerung
U_DIAG_DCDC_HV_OUT + - V - unsigned int - - 10 1 0 0 300 U_LV Systemgrenze für Steuerung

RES_0XF503

Dimensions: 1 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_HY_SYSTEM_ON_OFF - - + 0-n - unsigned char - TAB_HV_SYS_ON_OFF 1 1 0 0 - keine Anforderung 1 - Anforderung HV ein 2 - Anforderung HV aus

ARG_0XF503

Dimensions: 1 rows × 14 columns

ARG STR STPR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
ST_DIAG_HV_ANF + - 0-n - unsigned char - TAB_ST_DIAG_HV_ANF - - - - - HV-System Hoch- u. Runterfahren

RES_0XF504

Dimensions: 1 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_EME_PUMPE_WERT - - + - - unsigned char - - - - - 0= Ansteueuerung nicht aktiv 1 = Ansteuerung aktiv

ARG_0XF504

Dimensions: 1 rows × 14 columns

ARG STR STPR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
DREHZAHL_EME_PUMPE + - % - unsigned char - - - - - 0 100 Sollwert für Pumpemansteuerung

ARG_0XF505

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
ST_DME_LLR 0-n - unsigned char - TAB_ST_DME_LLR 1 1 0 0 1 Leerlaufregler der DME aktivieren

ARG_0XF506

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
ST_EM_GENERATOR 0-n - unsigned char - TAB_ST_EM_GENERATOR 1 1 0 0 1 HV-System Hoch- u. Runterfahren

ARG_0XF507

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
DUMMY - - unsigned char - - - - - - - wegen Kompatibilität zu ToolSet32

ARG_0XF508

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
DUMMY - - unsigned char - - - - - - - wegen Kompatibilität zu ToolSet32

RES_0XF509

Dimensions: 3 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_ENTLADEMODUS_WERT + + + - - unsigned char - - - - - 0 = n.i.O. (mindestens eine Voraussetzung ist nicht erfüllt) 1 = i.O.
STAT_SOC_SOLL_UNTEN_WERT + + + - - unsigned char - - - - - 0 = n.i.O. SoC-Soll_Unten ist kleiner als SoC-Min 1 = i.O SoC-Soll_Unten ist grösser als SoC-Min
STAT_ENTLADEN_HVB_WERT + + + - - unsigned char - - - - - Entladeprozess ist beendet 1 = Das Entladen ist abgeschlossen 0 = Das Entladen ist noch nicht abgeschlossen

ARG_0XF509

Dimensions: 2 rows × 14 columns

ARG STR STPR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
ENTLADEMODUS + - - - unsigned char - - - - - 0 1 Aufforderung des Testers an die EME den Entlademodus zu setzen: 0 = Keine Aufforderung, 1 = Aufforderung liegt vor
SOC_SOLL_UNTEN + - % - unsigned int - - - - - 0 100 Der untere SoC-Sollwert wird gesetzt (Beim Entladeprocess der anzusteuernde SoC-Wert)

RES_0XF50A

Dimensions: 3 rows × 13 columns

RESULTNAME STR STPR RRR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD INFO
STAT_LADEMODUS_WERT + + + - - unsigned char - - - - - 0 = n.i.O. (mindestens eine Voraussetzung ist nicht erfüllt) 1 = i.O.
STAT_SOC_SOLL_OBEN_WERT + + + - - unsigned char - - - - - 0 = n.i.O. SoC-Soll_Oben ist grösser als SoC-Max 1 = i.O SoC-Soll_Oben ist grösser als SoC-Max
STAT_LADEN_HVB_WERT + + + - - unsigned char - - - - - Ladeprozess ist beendet 1 = Das Laden ist abgeschlossen 0 = Das Laden ist noch nicht abgeschlossen

ARG_0XF50A

Dimensions: 2 rows × 14 columns

ARG STR STPR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
LADEMODUS + - - - unsigned char - - - - - 0 1 Auforderung des Testers an die EME den Lademodus zu setzen 1 Aufforderung vom Tester liegt vor 0 keine Aufforderung vom Tester
SOC_SOLL_OBEN + - % - unsigned int - - - - - 0 100 Der obere SoC-Sollwert wird gesetzt (Beim Ladeprocess der anzusteuernde SoC-Wert)

ARG_0XF50B

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
REFERENZKAPAZITAET_HVB As - unsigned int - - - - - 0 50000 Die auf dem Tester ermittelte Referenzkapazität wird auf die EME geschrieben

ARG_0XF50C

Dimensions: 3 rows × 14 columns

ARG STR STPR EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
EM_BETRIEBSART + - 0-n - unsigned char - TAB_EM_BETRIEBSART - - - 0 1 Betriebsart für EM-Steuerung: 0=Momentenvorgabe, 1= Drehzahlvorgabe
MOMENTENVORGABE + - Nm - signed int - - 0,1 - 0 - - Momentenvorgabe
DREHZAHLVORGABE + - 1/min - unsigned int - - 1 - 0 - - Drehzahlvorgabe

ARG_0XF50D

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
DUMMY - - unsigned char - - - - - - - wegen Kompatibilität zu ToolSet32

ARG_0XF50E

Dimensions: 1 rows × 12 columns

ARG EINHEIT L/H DATENTYP MASKE NAME MUL DIV ADD MIN MAX INFO
DUMMY - - unsigned char - - - - - - - wegen Kompatibilität zu ToolSet32

FUMWELTTEXTE

Dimensions: 5 rows × 9 columns

UWNR UWTEXT UW_EINH L/H UWTYP NAME MUL DIV ADD
0x1700 KM-Stand (3 Bytes 1Bit=1km) km - unsigned int - - - -
0x1701 Systemzeit (1Bit=1sec) sec - unsigned long - - - -
0x1702 SAE-Code (3 Bytes) - - unsigned int - - - -
0x4100 Systemstatus - - unsigned char - - - -
0x4101 Bordnetzstrom LV A - signed int - - 64 -