fla_20.prg
INFO
| Field | Value |
|---|---|
| ECU | Fernlicht-Assistent |
| ORIGIN | BMW EI-611 Stefan_Weidhaas |
| REVISION | 1.000 |
| AUTHOR | Gentex_GmbH EE Gundolf_Aichinger |
| COMMENT | FLA [41] |
| PACKAGE | 1.17 |
| SPRACHE | deutsch |
Jobs
Index
- INFO - Information SGBD
- INITIALISIERUNG - Initialisierung und Kommunikationsparameter
- IDENT - Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
- FS_LESEN - Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
- FS_LESEN_DETAIL - Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
- FS_LOESCHEN - Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
- PRUEFSTEMPEL_LESEN - Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
- PRUEFSTEMPEL_SCHREIBEN - Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
- SVK_LESEN - Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
- STATUS_LESEN - Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
- STEUERN - Vorgeben eines Status UDS : $2E WriteDataByIdentifier
- SERIENNUMMER_LESEN - Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
- STEUERN_IO - Vorgeben eines Status UDS : $2F InputOutputControlByIdentifier
- STEUERN_ROUTINE - Vorgeben eines Status UDS : $31 RoutineControl
- FS_SPERREN - Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
- IS_LESEN - Sekundaerer Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $22 ReadDataByIdentifierRequestServiceID UDS : $2000 DataIdentifier sekundaerer Fehlerspeicher Modus: Default
- IS_LESEN_DETAIL - sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $22 ReadDataByIdentifier UDS : $20 dataIdentifier UDS : $00 alle Info-Meldungen anschließend UDS : $20 dataIdentifier UDS : $nn Details zur Info-Meldung an der Position n Modus: Default
- IS_LOESCHEN - Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default
- STATUS_BLOCK_LESEN - Lesen eines dynamisch definierten Datenblockes UDS : $2C DynamicallyDefineDataIdentifier $03 ClearDynamicallyDefinedDataIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier UDS : $2C DynamicallyDefineDataIdentifier $01 DefineByIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier UDS : $22 ReadDataByIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier $2C$02 DefineByMemoryAddress wird nicht unterstützt 'Composite data blocks' werden nur komplett unterstützt
- HERSTELLINFO_LESEN - Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
- DIAGNOSE_AUFRECHT - Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
- DIAGNOSE_MODE - SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
- ENERGIESPARMODE - Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
- STATUS_ENERGIESPARMODE - Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
- STEUERGERAETE_RESET - Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
- STEUERN_ROE_STOP - Temporaeres Deaktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $00 Stop $02 (EventWindowTime)
- STATUS_ROE_REPORT - Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $04 report activated events
- STEUERN_ROE_START - Temporaeres Aktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $05 Start $02 (EventWindowTime)
- STEUERN_ROE_PERSISTENT_STOP - Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime)
- STEUERN_ROE_PERSISTENT_START - Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime)
- CPS_LESEN - Codierpruefstempel lesen UDS : $22 ReadDataByIdentifier UDS : $37FE DataIdentifier Codierpruefstempel Modus: Default
- DIAG_SESSION_LESEN - Aktive Diagnose-Session auslesen UDS : $22 ReadDataByIdentifier UDS : $F186 ActiveDiagnosticSession Modus: Default
- FLASH_TP_LESEN - Flash Timing Parameter auslesen UDS : $22 ReadDataByIdentifier UDS : $2504 FlashTimingParameter Modus: Default
- PROG_ZAEHLER_LESEN - Programmierzaehler lesen UDS : $22 ReadDataByIdentifier UDS : $2502 ProgrammingCounter Modus: Default
- PROG_MAX_LESEN - Anzahl der maximal möglichen Programmiervorgänge auslesen UDS : $22 ReadDataByIdentifier UDS : $2503 ProgrammingCounter Modus: Default
INFO
Information SGBD
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| ECU | string | Steuergerät im Klartext |
| ORIGIN | string | Steuergeräte-Verantwortlicher |
| REVISION | string | Versions-Nummer |
| AUTHOR | string | Namen aller Autoren |
| COMMENT | string | wichtige Hinweise |
| PACKAGE | string | Include-Paket-Nummer |
| SPRACHE | string | deutsch, english |
INITIALISIERUNG
Initialisierung und Kommunikationsparameter
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| DONE | int | 1, wenn Okay |
IDENT
Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| ID_SG_ADR | long | Steuergeraeteadresse |
| ID_SGBD_INDEX | long | Index zur Erkennung der SG-Variante |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FS_LESEN
Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FS_LESEN_DETAIL
Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| F_CODE | long | gewaehlter Fehlercode |
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_HFK | int | Haufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf |
| F_HLZ | int | Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Haufigkeitszaehler |
| F_UEBERLAUF | int | 0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers |
| F_FEHLERKLASSE_NR | int | 0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich ! |
| F_FEHLERKLASSE_TEXT | string | Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT |
| F_UW_ANZ | int | Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung |
| F_UW_KM | long | Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht |
| F_UW_ZEIT | long | Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_SAE_CODE | unsigned int | Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD |
| F_SAE_CODE_STRING | string | 5 stelliger Text in der Form 'Sxxxx' |
| F_SAE_CODE_TEXT | string | Text zu F_SAE_CODE |
| _RESPONSE_SNAPSHOT | binary | Hex-Antwort von SG |
| _RESPONSE_EXTENDED_DATA | binary | Hex-Antwort von SG |
| _RESPONSE_SEVERITY | binary | Hex-Antwort von SG |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
FS_LOESCHEN
Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| F_CODE | long | 0x??????: Angabe eines einzelnen Fehlers Default: 0xFFFFFF: alle Fehler |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PRUEFSTEMPEL_LESEN
Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| BYTE1 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE2 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE3 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PRUEFSTEMPEL_SCHREIBEN
Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| BYTE1 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE2 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE3 | int | Bereich: 0-255 bzw. 0x00-0xFF |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
SVK_LESEN
Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| SVK | string | table SVK_ID BEZEICHNUNG WERT default SVK_AKTUELL |
Results
| Name | Type | Comment |
|---|---|---|
| PROG_TEST | int | Programmierabhaengigkeiten (ProgrammingDependenciesChecked) 1: IO : Signaturpruefung und ProgrammingDependenciesCheck erfolgreich 2: NIO: mindestens eine SWE fehlerhaft oder ProgrammingDependenciesCheck nicht durchgefuehrt 3: NIO: mindestens eine SWE passt nicht mit einer HWE zusammen 4: NIO: mindestens eine SWE passt nicht mit einer anderen SWE zusammen sonst: reserviert |
| ANZAHL_EINHEITEN | int | Anzahl der xWEn |
| PROG_DATUM | string | Programmierdatum (DD.MM.YY) |
| PROG_KM | long | KM-Stand bei Programmierung (10 KM bis 655350 KM) Inkrement sind 10 KM -1: KM-Stand wird nicht unterstuetzt |
| PROZESSKLASSE_WERT | int | table Prozessklassen WERT dezimale Angabe der Prozessklasse |
| PROZESSKLASSE_TEXT | string | table Prozessklassen BEZEICHNUNG Text-Angabe der Prozessklasse |
| PROZESSKLASSE_KURZTEXT | string | table Prozessklassen PROZESSKLASSE Text-Angabe des Prozessklassenkurztextes |
| SGBM_IDENTIFIER | string | Angabe SGBM-ID der Prozessklasse |
| VERSION | string | Angabe der Version der Prozessklasse |
| SGBM_ID | string | Angabe von Prozessklasse, SGBM-Identifier, Version |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_LESEN
Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Es muss mindestens ein Argument übergeben werden Es wird das zugehörige result erzeugt table SG_Funktionen ARG ID RESULTNAME RES_TABELLE ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN
Vorgeben eines Status UDS : $2E WriteDataByIdentifier
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Siehe table SG_Funktionen ARG ID LABEL ARG_TABELLE |
| WERT | string | Es muss mindestens ein Argument übergeben werden Argumente siehe table SG_Funktionen ARG ID ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
SERIENNUMMER_LESEN
Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| SERIENNUMMER | string | Seriennummer des Steuergeraets |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_IO
Vorgeben eines Status UDS : $2F InputOutputControlByIdentifier
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Siehe table SG_Funktionen ARG ID RES_TABELLE ARG_TABELLE |
| STEUERPARAMETER | string | 'RCTECU' = returnControlToECU 'RTD' = resetToDefault 'FCS' = freezeCurrentState 'STA' = shortTermAdjustment optionales Argument Wenn nicht angegeben, dann kein InputOutputControlParameter im Request |
| WERT | string | Argumente siehe table SG_Funktionen ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROUTINE
Vorgeben eines Status UDS : $31 RoutineControl
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Siehe table SG_Funktionen ARG ID RES_TABELLE ARG_TABELLE |
| STEUERPARAMETER | string | 'STR' = startRoutine 'STPR' = stopRoutine 'RRR' = requestRoutineResults |
| WERT | string | Argumente siehe table SG_Funktionen ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FS_SPERREN
Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| SPERREN | string | "ja" -> Fehlerspeicher sperren "nein" -> Fehlerspeicher freigeben table DigitalArgument TEXT Default: "ja" |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
IS_LESEN
Sekundaerer Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $22 ReadDataByIdentifierRequestServiceID UDS : $2000 DataIdentifier sekundaerer Fehlerspeicher Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
IS_LESEN_DETAIL
sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $22 ReadDataByIdentifier UDS : $20 dataIdentifier UDS : $00 alle Info-Meldungen anschließend UDS : $20 dataIdentifier UDS : $nn Details zur Info-Meldung an der Position n Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| F_CODE | long | gewaehlter Infocode Wenn dieser Parameter angegeben wird, wird die Position automatisch ermittelt. Es darf dann nicht argument F_POS angegeben werden |
| F_POS | int | gewaehlter Eintrag Wenn dieser Parameter angegeben wird, wird die Position benutzt. Wertebereich 1 - 255 Es darf dann nicht argument F_CODE angegeben werden |
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_HFK | int | Haufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf |
| F_HLZ | int | Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Haufigkeitszaehler |
| F_UEBERLAUF | int | 0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers |
| F_FEHLERKLASSE_NR | int | 0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich ! |
| F_FEHLERKLASSE_TEXT | string | Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT |
| F_UW_ANZ | int | Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung |
| F_UW_KM | long | Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht |
| F_UW_ZEIT | long | Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_SAE_CODE | unsigned int | Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD |
| F_SAE_CODE_STRING | string | 5 stelliger Text in der Form 'Sxxxx' |
| F_SAE_CODE_TEXT | string | Text zu F_SAE_CODE |
| _RESPONSE_2000 | binary | Hex-Antwort von SG |
| _RESPONSE_200X | binary | Hex-Antwort von SG |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
IS_LOESCHEN
Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_BLOCK_LESEN
Lesen eines dynamisch definierten Datenblockes UDS : $2C DynamicallyDefineDataIdentifier $03 ClearDynamicallyDefinedDataIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier UDS : $2C DynamicallyDefineDataIdentifier $01 DefineByIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier UDS : $22 ReadDataByIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier $2C$02 DefineByMemoryAddress wird nicht unterstützt 'Composite data blocks' werden nur komplett unterstützt
Arguments
| Name | Type | Comment |
|---|---|---|
| BLOCK_NR | long | Nummer des Blockes 0..255 |
| NEU_DEFINIEREN | string | Wenn 'JA' oder 'YES' wird der Block im SG gelöscht und neu ins SG geschrieben Wenn 'NEIN' oder 'NO' wird der Block im SG nicht gelöscht und nicht geschrieben Anschließend wird der Block gelesen |
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Es muss mindestens ein Argument übergeben werden Es wird das zugehörige Result table SG_Funktionen ARG ID RESULTNAME erzeugt |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST_1 | binary | Hex-Antwort von SG |
| _RESPONSE_1 | binary | Hex-Antwort von SG |
| _REQUEST_2 | binary | Hex-Antwort von SG |
| _RESPONSE_2 | binary | Hex-Antwort von SG |
| _REQUEST_3 | binary | Hex-Antwort von SG |
| _RESPONSE_3 | binary | Hex-Antwort von SG |
HERSTELLINFO_LESEN
Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| ID_LIEF_NR | long | Lieferantennummer 0xFFFFFF, falls nicht vorhanden |
| ID_LIEF_TEXT | string | Text zu ID_LIEF_NR table Lieferanten LIEF_TEXT unbekannter Hersteller, falls nicht vorhanden |
| ID_DATUM | string | Herstelldatum (DD.MM.YY) |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
| _REQUEST_2 | binary | Hex-Auftrag an SG |
| _RESPONSE_2 | binary | Hex-Antwort von SG |
DIAGNOSE_AUFRECHT
Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| SG_ANTWORT | string | "ja" -> SG soll antworten "nein" -> SG soll nicht antworten table DigitalArgument TEXT Default: SG soll antworten |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
DIAGNOSE_MODE
SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
Arguments
| Name | Type | Comment |
|---|---|---|
| MODE | string | gewuenschter Diagnose-Modus table DiagMode MODE MODE_TEXT Defaultwert: DEFAULT (DefaultMode) |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
ENERGIESPARMODE
Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
Arguments
| Name | Type | Comment |
|---|---|---|
| MODE | int | 0x00: Normalmode 0x01: Fertigungsmode 0x02: Transportmode 0x03: Flashmode |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_ENERGIESPARMODE
Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_ENERGIESPARMODE_WERT | int | Ausgabe des Energiesparmodes 0: Kein Energiesparmode gesetzt 1: Produktionsmode gesetzt 2: Transportmode gesetzt 3: Flashmode gesetzt -1: Mode ungueltig |
| STAT_ENERGIESPARMODE_TEXT | string | Text zu STAT_ENERGIESPARMODE_WERT |
| STAT_PRODUKTIONSMODE_EIN | int | 0: Produktionsmode nicht aktiv 1: Produktionsmode aktiv |
| STAT_TRANSPORTMODE_EIN | int | 0: Transportmode nicht aktiv 1: Transportmode aktiv |
| STAT_FLASHMODE_EIN | int | 0: Flashmode nicht aktiv 1: Flashmode aktiv |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERGERAETE_RESET
Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_STOP
Temporaeres Deaktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $00 Stop $02 (EventWindowTime)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_ROE_REPORT
Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $04 report activated events
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_ROE_AKTIV | char | 0x00 = Aktive Fehlermeldung deaktiviert 0x01 = Aktive Fehlermeldung aktiviert 0xFF = Status der aktiven Fehlermeldung nicht feststellbar |
| STAT_ROE_AKTIV_TEXT | string | Interpretation von STAT_ROE_AKTIV table UDS_TAB_ROE_AKTIV TEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_START
Temporaeres Aktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $05 Start $02 (EventWindowTime)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_PERSISTENT_STOP
Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_PERSISTENT_START
Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
CPS_LESEN
Codierpruefstempel lesen UDS : $22 ReadDataByIdentifier UDS : $37FE DataIdentifier Codierpruefstempel Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| CPS | string | Codierpruefstempel 7-stellig |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
DIAG_SESSION_LESEN
Aktive Diagnose-Session auslesen UDS : $22 ReadDataByIdentifier UDS : $F186 ActiveDiagnosticSession Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| DIAG_SESSION_WERT | int | Diagnose-Session (1 Byte) |
| DIAG_SESSION_TEXT | string | Diagnose-Session als Text |
| DIAG_DETAIL_WERT | int | Details zur Diagnose-Session (1 Byte) |
| DIAG_DETAIL_TEXT | string | Details zur Diagnose-Session als Text |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FLASH_TP_LESEN
Flash Timing Parameter auslesen UDS : $22 ReadDataByIdentifier UDS : $2504 FlashTimingParameter Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| FLASH_LOESCHEN | int | EraseMemoryTime (2 Byte) |
| FLASH_TEST | int | CheckMemoryTime (2 Byte) |
| FLASH_BOOT | int | BootloaderInstallationTime (2 Byte) |
| FLASH_AUTHENT | int | AuthenticationTime (2 Byte) |
| FLASH_RESET | int | ResetTime (2 Byte) |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PROG_ZAEHLER_LESEN
Programmierzaehler lesen UDS : $22 ReadDataByIdentifier UDS : $2502 ProgrammingCounter Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| PROG_ZAEHLER_STATUS_WERT | int | Status, wie oft das SG programmierbar ist |
| PROG_ZAEHLER_STATUS_TEXT | string | Status, wie oft das SG programmierbar ist |
| PROG_ZAEHLER | int | Programmierzaehler |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PROG_MAX_LESEN
Anzahl der maximal möglichen Programmiervorgänge auslesen UDS : $22 ReadDataByIdentifier UDS : $2503 ProgrammingCounter Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| PROG_MAX | long | maximal mögliche Programmiervorgänge Sonderfall 0xFFFF: Anzahl der Programmiervorgänge unbegrenzt |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
Tables
Index
- JOBRESULT (66 × 2)
- LIEFERANTEN (121 × 2)
- FARTTEXTE (19 × 2)
- DIGITALARGUMENT (17 × 2)
- PROZESSKLASSEN (24 × 3)
- SVK_ID (65 × 2)
- DTCEXTENDEDDATARECORDNUMBER (5 × 3)
- DTCSNAPSHOTIDENTIFIER (5 × 9)
- FEHLERKLASSE (5 × 2)
- DIAGMODE (11 × 3)
- IARTTEXTE (18 × 2)
- UDS_TAB_ROE_AKTIV (3 × 2)
- JOBRESULTEXTENDED (1 × 2)
- BETRIEBSMODE (6 × 3)
- FORTTEXTE (49 × 3)
- FDETAILSTRUKTUR (6 × 2)
- IORTTEXTE (5 × 3)
- IDETAILSTRUKTUR (4 × 2)
- SG_FUNKTIONEN (13 × 16)
- TAB_INIT (3 × 2)
- TAB_FLA_CONTROL (4 × 2)
- RES_0XD341 (8 × 10)
- RES_0XD370 (4 × 10)
- RES_0XD371 (5 × 10)
- RES_0XD372 (4 × 10)
- ARG_0XD3A6 (1 × 12)
- RES_0XD3AD (5 × 10)
- ARG_0XD3AD (5 × 12)
- TAB_STFLA_CONTROL (4 × 2)
- TAB_FLA_EMPFEHLUNG (4 × 2)
- ARG_0XD3B7 (2 × 12)
- TAB_FLA_AXIS (2 × 2)
- ARG_0XD3B8 (1 × 12)
- RES_0XA375 (3 × 13)
- ARG_0XA375 (3 × 14)
- RES_0XA376 (6 × 13)
- ARG_0XA376 (3 × 14)
- TAB_FLA_AIM_RESULT (6 × 2)
- TAB_FLA_AXIS_HV (3 × 2)
- RES_0X4001 (6 × 10)
- ARG_0X4006 (1 × 12)
JOBRESULT
Dimensions: 66 rows × 2 columns
| SB | STATUS_TEXT |
|---|---|
| 0x10 | ERROR_ECU_GENERAL_REJECT |
| 0x11 | ERROR_ECU_SERVICE_NOT_SUPPORTED |
| 0x12 | ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED |
| 0x13 | ERROR_ECU_INCORRECT_MESSAGE_LENGTH_OR_INVALID_FORMAT |
| 0x14 | ERROR_ECU_RESPONSE_TOO_LONG |
| 0x21 | ERROR_ECU_BUSY_REPEAT_REQUEST |
| 0x22 | ERROR_ECU_CONDITIONS_NOT_CORRECT |
| 0x24 | ERROR_ECU_REQUEST_SEQUENCE_ERROR |
| 0x25 | ERROR_ECU_NO_RESPONSE_FROM_SUBNET_COMPONENT |
| 0x26 | ERROR_ECU_FAILURE_PREVENTS_EXECUTION_OF_REQUESTED_ACTION |
| 0x31 | ERROR_ECU_REQUEST_OUT_OF_RANGE |
| 0x33 | ERROR_ECU_SECURITY_ACCESS_DENIED |
| 0x35 | ERROR_ECU_INVALID_KEY |
| 0x36 | ERROR_ECU_EXCEED_NUMBER_OF_ATTEMPTS |
| 0x37 | ERROR_ECU_REQUIRED_TIME_DELAY_NOT_EXPIRED |
| 0x70 | ERROR_ECU_UPLOAD_DOWNLOAD_NOT_ACCEPTED |
| 0x71 | ERROR_ECU_TRANSFER_DATA_SUSPENDED |
| 0x72 | ERROR_ECU_GENERAL_PROGRAMMING_FAILURE |
| 0x73 | ERROR_ECU_WRONG_BLOCK_SEQUENCE_COUNTER |
| 0x78 | ERROR_ECU_REQUEST_CORRECTLY_RECEIVED__RESPONSE_PENDING |
| 0x7E | ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED_IN_ACTIVE_SESSION |
| 0x7F | ERROR_ECU_SERVICE_NOT_SUPPORTED_IN_ACTIVE_SESSION |
| 0x81 | ERROR_ECU_RPM_TOO_HIGH |
| 0x82 | ERROR_ECU_RPM_TOO_LOW |
| 0x83 | ERROR_ECU_ENGINE_IS_RUNNING |
| 0x84 | ERROR_ECU_ENGINE_IS_NOT_RUNNING |
| 0x85 | ERROR_ECU_ENGINE_RUN_TIME_TOO_LOW |
| 0x86 | ERROR_ECU_TEMPERATURE_TOO_HIGH |
| 0x87 | ERROR_ECU_TEMPERATURE_TOO_LOW |
| 0x88 | ERROR_ECU_VEHICLE_SPEED_TOO_HIGH |
| 0x89 | ERROR_ECU_VEHICLE_SPEED_TOO_LOW |
| 0x8A | ERROR_ECU_THROTTLE_PEDAL_TOO_HIGH |
| 0x8B | ERROR_ECU_THROTTLE_PEDAL_TOO_LOW |
| 0x8C | ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_NEUTRAL |
| 0x8D | ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_GEAR |
| 0x8F | ERROR_ECU_BRAKE_SWITCH_NOT_CLOSED |
| 0x90 | ERROR_ECU_SHIFTER_LEVER_NOT_IN_PARK |
| 0x91 | ERROR_ECU_TORQUE_CONVERTER_CLUTCH_LOCKED |
| 0x92 | ERROR_ECU_VOLTAGE_TOO_HIGH |
| 0x93 | ERROR_ECU_VOLTAGE_TOO_LOW |
| ?00? | OKAY |
| ?01? | ERROR_ECU_NO_RESPONSE |
| ?02? | ERROR_ECU_INCORRECT_LEN |
| ?03? | ERROR_ECU_INCORRECT_RESPONSE_ID |
| ?04? | ERROR_ECU_TA_RESPONSE_NOT_SA_REQUEST |
| ?05? | ERROR_ECU_SA_RESPONSE_NOT_TA_REQUEST |
| ?06? | ERROR_ECU_RESPONSE_INCORRECT_DATA_IDENTIFIER |
| ?07? | ERROR_ECU_RESPONSE_TOO_MUCH_DATA |
| ?08? | ERROR_ECU_RESPONSE_TOO_LESS_DATA |
| ?09? | ERROR_ECU_RESPONSE_VALUE_OUT_OF_RANGE |
| ?0A? | ERROR_TABLE |
| ?10? | ERROR_F_CODE |
| ?12? | ERROR_INTERPRETATION |
| ?13? | ERROR_F_POS |
| ?14? | ERROR_ECU_RESPONSE_INCORRECT_IO_CONTROL_PARAMETER |
| ?15? | ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_CONTROL_TYPE |
| ?16? | ERROR_ECU_RESPONSE_INCORRECT_SUB_FUNCTION |
| ?17? | ERROR_ECU_RESPONSE_INCORRECT_DYNAMICALLY_DEFINED_DATA_IDENTIFIER |
| ?18? | ERROR_ECU_RESPONSE_NO_STRING_END_CHAR |
| ?50? | ERROR_BYTE1 |
| ?51? | ERROR_BYTE2 |
| ?52? | ERROR_BYTE3 |
| ?80? | ERROR_SVK_INCORRECT_LEN |
| ?81? | ERROR_SVK_INCORRECT_FINGERPRINT |
| ?F0? | ERROR_ARGUMENT |
| 0xXY | ERROR_ECU_UNKNOWN_NEGATIVE_RESPONSE |
LIEFERANTEN
Dimensions: 121 rows × 2 columns
| LIEF_NR | LIEF_TEXT |
|---|---|
| 0x000001 | Reinshagen => Delphi |
| 0x000002 | Kostal |
| 0x000003 | Hella |
| 0x000004 | Siemens |
| 0x000005 | Eaton |
| 0x000006 | UTA |
| 0x000007 | Helbako |
| 0x000008 | Bosch |
| 0x000009 | Loewe => Lear |
| 0x000010 | VDO |
| 0x000011 | Valeo |
| 0x000012 | MBB |
| 0x000013 | Kammerer |
| 0x000014 | SWF |
| 0x000015 | Blaupunkt |
| 0x000016 | Philips |
| 0x000017 | Alpine |
| 0x000018 | Continental Teves |
| 0x000019 | Elektromatik Suedafrika |
| 0x000020 | Becker |
| 0x000021 | Preh |
| 0x000022 | Alps |
| 0x000023 | Motorola |
| 0x000024 | Temic |
| 0x000025 | Webasto |
| 0x000026 | MotoMeter |
| 0x000027 | Delphi PHI |
| 0x000028 | DODUCO => BERU |
| 0x000029 | DENSO |
| 0x000030 | NEC |
| 0x000031 | DASA |
| 0x000032 | Pioneer |
| 0x000033 | Jatco |
| 0x000034 | Fuba |
| 0x000035 | UK-NSI |
| 0x000036 | AABG |
| 0x000037 | Dunlop |
| 0x000038 | Sachs |
| 0x000039 | ITT |
| 0x000040 | FTE |
| 0x000041 | Megamos |
| 0x000042 | TRW |
| 0x000043 | Wabco |
| 0x000044 | ISAD Electronic Systems |
| 0x000045 | HEC (Hella Electronics Corporation) |
| 0x000046 | Gemel |
| 0x000047 | ZF |
| 0x000048 | GMPT |
| 0x000049 | Harman Kardon |
| 0x000050 | Remes |
| 0x000051 | ZF Lenksysteme |
| 0x000052 | Magneti Marelli |
| 0x000053 | Borg Instruments |
| 0x000054 | GETRAG |
| 0x000055 | BHTC (Behr Hella Thermocontrol) |
| 0x000056 | Siemens VDO Automotive |
| 0x000057 | Visteon |
| 0x000058 | Autoliv |
| 0x000059 | Haberl |
| 0x000060 | Magna Steyr |
| 0x000061 | Marquardt |
| 0x000062 | AB-Elektronik |
| 0x000063 | Siemens VDO Borg |
| 0x000064 | Hirschmann Electronics |
| 0x000065 | Hoerbiger Electronics |
| 0x000066 | Thyssen Krupp Automotive Mechatronics |
| 0x000067 | Gentex GmbH |
| 0x000068 | Atena GmbH |
| 0x000069 | Magna-Donelly |
| 0x000070 | Koyo Steering Europe |
| 0x000071 | NSI B.V |
| 0x000072 | AISIN AW CO.LTD |
| 0x000073 | Shorlock |
| 0x000074 | Schrader |
| 0x000075 | BERU Electronics GmbH |
| 0x000076 | CEL |
| 0x000077 | Audio Mobil |
| 0x000078 | rd electronic |
| 0x000079 | iSYS RTS GmbH |
| 0x000080 | Westfalia Automotive GmbH |
| 0x000081 | Tyco Electronics |
| 0x000082 | Paragon AG |
| 0x000083 | IEE S.A |
| 0x000084 | TEMIC AUTOMOTIVE of NA |
| 0x000085 | AKsys GmbH |
| 0x000086 | META System |
| 0x000087 | Hülsbeck & Fürst GmbH & Co KG |
| 0x000088 | Mann & Hummel Automotive GmbH |
| 0x000089 | Brose Fahrzeugteile GmbH & Co |
| 0x000090 | Keihin |
| 0x000091 | Vimercati S.p.A. |
| 0x000092 | CRH |
| 0x000093 | TPO Display Corp. |
| 0x000094 | KÜSTER Automotive Control |
| 0x000095 | Hitachi Automotive |
| 0x000096 | Continental Automotive |
| 0x000097 | TI-Automotive |
| 0x000098 | Hydro |
| 0x000099 | Johnson Controls |
| 0x00009A | Takata- Petri |
| 0x00009B | Mitsubishi Electric B.V. (Melco) |
| 0x00009C | Autokabel |
| 0x00009D | GKN-Driveline |
| 0x00009E | Zollner Elektronik AG |
| 0x00009F | PEIKER acustics GmbH |
| 0x0000A0 | Bosal-Oris |
| 0x0000A1 | Cobasys |
| 0x0000A2 | Lighting Reutlingen GmbH |
| 0x0000A3 | CONTI VDO |
| 0x0000A4 | ADC Automotive Distance Control Systems GmbH |
| 0x0000A5 | Funkwerk Dabendorf GmbH |
| 0x0000A6 | Lame |
| 0x0000A7 | Magna/Closures |
| 0x0000A8 | Wanyu |
| 0x0000A9 | Thyssen Krupp Presta |
| 0x0000AA | ArvinMeritor |
| 0x0000AB | Kongsberg Automotive GmbH |
| 0x0000AC | SMR Automotive Mirrors |
| 0x0000AD | So.Ge.Mi. |
| 0x0000AE | MTA |
| 0xFFFFFF | unbekannter Hersteller |
FARTTEXTE
Dimensions: 19 rows × 2 columns
| ARTNR | ARTTEXT |
|---|---|
| 0x00 | keine Fehlerart verfügbar |
| 0x04 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x05 | Fehler momentan vorhanden und bereits gespeichert |
| 0x08 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x09 | Fehler momentan vorhanden und bereits gespeichert |
| 0x0C | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x0D | Fehler momentan vorhanden und bereits gespeichert |
| 0x40 | unbekannte Fehlerart |
| 0x44 | Fehler gespeichert |
| 0x45 | Fehler gespeichert |
| 0x48 | Fehler gespeichert |
| 0x49 | Fehler gespeichert |
| 0x4C | Fehler gespeichert |
| 0x4D | Fehler gespeichert |
| 0x10 | Testbedingungen erfüllt |
| 0x11 | Testbedingungen noch nicht erfüllt |
| 0x80 | Fehler würde kein Aufleuchten einer Warnlampe verursachen |
| 0x81 | Fehler würde das Aufleuchten einer Warnlampe verursachen |
| 0xFF | unbekannte Fehlerart |
DIGITALARGUMENT
Dimensions: 17 rows × 2 columns
| TEXT | WERT |
|---|---|
| ein | 1 |
| aus | 0 |
| ja | 1 |
| nein | 0 |
| auf | 1 |
| ab | 0 |
| an | 1 |
| yes | 1 |
| no | 0 |
| on | 1 |
| off | 0 |
| up | 1 |
| down | 0 |
| true | 1 |
| false | 0 |
| 1 | 1 |
| 0 | 0 |
PROZESSKLASSEN
Dimensions: 24 rows × 3 columns
| WERT | PROZESSKLASSE | BEZEICHNUNG |
|---|---|---|
| 0x00 | - | ungueltig |
| 0x01 | HWEL | Hardware (Elektronik) |
| 0x02 | HWAP | Hardwareauspraegung |
| 0x03 | HWFR | Hardwarefarbe |
| 0x05 | CAFD | Codierdaten |
| 0x06 | BTLD | Bootloader |
| 0x08 | SWFL | Software ECU Speicherimage |
| 0x09 | SWFF | Flash File Software |
| 0x0A | SWPF | Pruefsoftware |
| 0x0B | ONPS | Onboard Programmiersystem |
| 0x0F | FAFP | FA2FP |
| 0x1A | TLRT | Temporaere Loeschroutine |
| 0x1B | TPRG | Temporaere Programmierroutine |
| 0x07 | FLSL | Flashloader Slave |
| 0x0C | IBAD | Interaktive Betriebsanleitung Daten |
| 0x10 | FCFA | Freischaltcode Fahrzeug-Auftrag |
| 0x1C | BLUP | Bootloader-Update Applikation |
| 0x1D | FLUP | Flashloader-Update Applikation |
| 0xA0 | ENTD | Entertainment Daten |
| 0xA1 | NAVD | Navigation Daten |
| 0xA2 | FCFN | Freischaltcode Funktion |
| 0xC0 | SWUP | Software-Update Package |
| 0xC1 | SWIP | Index Software-Update Package |
| 0xFF | - | ungueltig |
SVK_ID
Dimensions: 65 rows × 2 columns
| WERT | BEZEICHNUNG |
|---|---|
| 0x01 | SVK_AKTUELL |
| 0x02 | SVK_SUPPLIER |
| 0x03 | SVK_WERK |
| 0x04 | SVK_BACKUP_01 |
| 0x05 | SVK_BACKUP_02 |
| 0x06 | SVK_BACKUP_03 |
| 0x07 | SVK_BACKUP_04 |
| 0x08 | SVK_BACKUP_05 |
| 0x09 | SVK_BACKUP_06 |
| 0x0A | SVK_BACKUP_07 |
| 0x0B | SVK_BACKUP_08 |
| 0x0C | SVK_BACKUP_09 |
| 0x0D | SVK_BACKUP_10 |
| 0x0E | SVK_BACKUP_11 |
| 0x0F | SVK_BACKUP_12 |
| 0x10 | SVK_BACKUP_13 |
| 0x11 | SVK_BACKUP_14 |
| 0x12 | SVK_BACKUP_15 |
| 0x13 | SVK_BACKUP_16 |
| 0x14 | SVK_BACKUP_17 |
| 0x15 | SVK_BACKUP_18 |
| 0x16 | SVK_BACKUP_19 |
| 0x17 | SVK_BACKUP_20 |
| 0x18 | SVK_BACKUP_21 |
| 0x19 | SVK_BACKUP_22 |
| 0x1A | SVK_BACKUP_23 |
| 0x1B | SVK_BACKUP_24 |
| 0x1C | SVK_BACKUP_25 |
| 0x1D | SVK_BACKUP_26 |
| 0x1E | SVK_BACKUP_27 |
| 0x1F | SVK_BACKUP_28 |
| 0x20 | SVK_BACKUP_29 |
| 0x21 | SVK_BACKUP_30 |
| 0x22 | SVK_BACKUP_31 |
| 0x23 | SVK_BACKUP_32 |
| 0x24 | SVK_BACKUP_33 |
| 0x25 | SVK_BACKUP_34 |
| 0x26 | SVK_BACKUP_35 |
| 0x27 | SVK_BACKUP_36 |
| 0x28 | SVK_BACKUP_37 |
| 0x29 | SVK_BACKUP_38 |
| 0x2A | SVK_BACKUP_39 |
| 0x2B | SVK_BACKUP_40 |
| 0x2C | SVK_BACKUP_41 |
| 0x2D | SVK_BACKUP_42 |
| 0x2E | SVK_BACKUP_43 |
| 0x2F | SVK_BACKUP_44 |
| 0x30 | SVK_BACKUP_45 |
| 0x31 | SVK_BACKUP_46 |
| 0x32 | SVK_BACKUP_47 |
| 0x33 | SVK_BACKUP_48 |
| 0x34 | SVK_BACKUP_49 |
| 0x35 | SVK_BACKUP_50 |
| 0x36 | SVK_BACKUP_51 |
| 0x37 | SVK_BACKUP_52 |
| 0x38 | SVK_BACKUP_53 |
| 0x39 | SVK_BACKUP_54 |
| 0x3A | SVK_BACKUP_55 |
| 0x3B | SVK_BACKUP_56 |
| 0x3C | SVK_BACKUP_57 |
| 0x3D | SVK_BACKUP_58 |
| 0x3E | SVK_BACKUP_59 |
| 0x3F | SVK_BACKUP_60 |
| 0x40 | SVK_BACKUP_61 |
| 0xXY | ERROR_UNKNOWN |
DTCEXTENDEDDATARECORDNUMBER
Dimensions: 5 rows × 3 columns
| WERT | TEXT | ANZ_BYTE |
|---|---|---|
| 0x00 | ISO_RESERVED | 0 |
| 0x01 | CONDITION_BYTE | 1 |
| 0x02 | HFK | 1 |
| 0x03 | HLZ | 1 |
| 0xFF | RECORD_UNKNOWN | 0 |
DTCSNAPSHOTIDENTIFIER
Dimensions: 5 rows × 9 columns
| UWNR | UWTEXT | UW_EINH | L/H | UWTYP | NAME | MUL | DIV | ADD |
|---|---|---|---|---|---|---|---|---|
| 0x1700 | KM_STAND | 0-n | - | 0xFFFFFF | - | 1 | 1 | 0.000000 |
| 0x1701 | ABS_ZEIT | 0-n | - | 0xFFFFFFFF | - | 1 | 1 | 0.000000 |
| 0x1702 | SAE_CODE | 0-n | - | 0xFFFFFF | - | 1 | 1 | 0.000000 |
| 0x1731 | Fehlerklasse_DTC | - | - | u char | - | 1 | 1 | 0.000000 |
| 0xFFFF | IDENTIFIER_UNKNOWN | - | - | 0xFFFFFF | - | 1 | 1 | 0.000000 |
FEHLERKLASSE
Dimensions: 5 rows × 2 columns
| NR | TEXT |
|---|---|
| 0x00 | Keine Fehlerklasse verfuegbar |
| 0x01 | Ueberpruefung bei naechstem Werkstattbesuch |
| 0x02 | Ueberpruefung bei naechstem Halt |
| 0x04 | Ueberpruefung sofort erforderlich ! |
| 0xFF | unbekannte Fehlerklasse |
DIAGMODE
Dimensions: 11 rows × 3 columns
| NR | MODE | MODE_TEXT |
|---|---|---|
| 0x00 | UNGUELTIG | DefaultMode |
| 0x01 | DEFAULT | DefaultMode |
| 0x02 | ECUPM | ECUProgrammingMode |
| 0x03 | ECUEXTDIAG | ECUExtendedDiagnosticSession |
| 0x04 | ECUSSDS | ECUSafetySystemDiagnosticSession |
| 0x40 | ECUEOL | ECUEndOfLineSession |
| 0x41 | ECUCODE | ECUCodingSession |
| 0x42 | ECUSWT | ECUSwtSession |
| 0x43 | ECUHDD | ECUHDDDownloadSession |
| 0x4F | ECUDEVELOP | ECUDevelopmentSession |
| 0xXY | -- | unbekannter Diagnose-Mode |
IARTTEXTE
Dimensions: 18 rows × 2 columns
| ARTNR | ARTTEXT |
|---|---|
| 0x00 | keine Fehlerart verfügbar |
| 0x04 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x05 | Fehler momentan vorhanden und bereits gespeichert |
| 0x08 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x09 | Fehler momentan vorhanden und bereits gespeichert |
| 0x0C | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x0D | Fehler momentan vorhanden und bereits gespeichert |
| 0x44 | Fehler gespeichert |
| 0x45 | Fehler gespeichert |
| 0x48 | Fehler gespeichert |
| 0x49 | Fehler gespeichert |
| 0x4C | Fehler gespeichert |
| 0x4D | Fehler gespeichert |
| 0x10 | Testbedingungen erfüllt |
| 0x11 | Testbedingungen noch nicht erfüllt |
| 0x80 | Fehler würde kein Aufleuchten einer Warnlampe verursachen |
| 0x81 | Fehler würde das Aufleuchten einer Warnlampe verursachen |
| 0xFF | unbekannte Fehlerart |
UDS_TAB_ROE_AKTIV
Dimensions: 3 rows × 2 columns
| NR | TEXT |
|---|---|
| 0x00 | Aktive Fehlermeldung deaktiviert |
| 0x01 | Aktive Fehlermeldung aktiviert |
| 0xFF | Status der aktiven Fehlermeldung nicht feststellbar |
JOBRESULTEXTENDED
Dimensions: 1 rows × 2 columns
| SB | STATUS_TEXT |
|---|---|
| 0xXY | ERROR_UNKNOWN |
BETRIEBSMODE
Dimensions: 6 rows × 3 columns
| WERT | TEXT | BEDEUTUNG |
|---|---|---|
| 0x00 | Allgemeiner Fertigungs- und Energiesparmode | Hier deaktivierte Funktionen gemäß FeTra-Liste festhalten |
| 0x01 | Spezieller Energiesparmode | - |
| 0x02 | ECOS-Mode | - |
| 0x03 | MOST-Mode | - |
| 0x04 | Rollenmode | - |
| 0xFF | ungültiger Betriebsmode | ungültig |
FORTTEXTE
Dimensions: 49 rows × 3 columns
| ORT | ORTTEXT | EREIGNIS_DTC |
|---|---|---|
| 0x800609 | Horizontale Dejustage erkannt | 0 |
| 0xE0C468 | BODY-CAN Control Module Bus OFF | 0 |
| 0x800614 | Codierung: Codierung passt nicht zum Fahrzeug | 0 |
| 0x800615 | Codierung: Unplausible Daten während Transaktion | 0 |
| 0xE0EC03 | Signal (0x1a1) ungültig empfangen: Fahrzustand Fahrzeug, Geschwindigkeit_Fahrzeug_Schwerpunkt | 1 |
| 0xE0D404 | Botschaft (0x380 , Fahrgestellnummer): Ausfall | 1 |
| 0xE0EC06 | Signal (0x21A) ungültig empfangen: Status Abblendlicht | 1 |
| 0x80060B | Sensitivität verstellt | 1 |
| 0x800604 | Temperatur unterhalb des Arbeitsbereichs | 1 |
| 0xE0D409 | Botschaft (0x21a , Lampenzustand): Ausfall | 1 |
| 0x025F00 | Energiesparmode aktiv | 0 |
| 0x800608 | Sensorsichtfeld verdeckt | 1 |
| 0xE0D410 | Botschaft (0x96, Status_Stufenloser_Fernlichtassistent): Ausfall | 1 |
| 0x800613 | Codierung: Signatur für Daten ungültig | 0 |
| 0xE0EC05 | Signal (0x19f) ungültig empfangen: Giergeschwindigkeit Fahrzeug | 1 |
| 0x80060C | ALS-Sensor defekt | 0 |
| 0x800605 | Temperatur oberhalb des Arbeitsbereichs | 1 |
| 0xE0EC0F | Signal (0x2ca) ungültig empfangen: Temperatur Außen | 1 |
| 0x800611 | Codierung: Steuergerät ist nicht codiert | 0 |
| 0xE0D401 | Botschaft (0x1ee , Bedienung Lenkstocktaster): Ausfall | 1 |
| 0x800603 | Interner Softwarefehler | 0 |
| 0xE0EC09 | Signal (0x12F) ungültig empfangen:Status Fahrzeug_Zustand, Status Klemme 15N | 1 |
| 0xE0D400 | Botschaft (0x2ca , Aussentemperatur): Ausfall | 1 |
| 0x800607 | Überspannung erkannt | 1 |
| 0xE0D40F | Botschaft (0x12F, Klemmen) Ausfall | 1 |
| 0xE0EC01 | Signal (0x3f9) ungültig empfangen: Status Gangwahl Antrieb | 1 |
| 0xE0D402 | Botschaft (0x3f9 , Daten Antriebsstrang 2): Ausfall | 1 |
| 0x800612 | Codierung: Fehler bei Codierung aufgetreten | 0 |
| 0x80060A | Vertikale Dejustage erkannt | 0 |
| 0xE0D407 | Botschaft (0x19f, Giergeschwindigkeit Fahrzeug): Ausfall | 1 |
| 0xE0D40E | Botschaft (0x3b0 , Status Gang Rückwärts): Ausfall | 1 |
| 0x800606 | Unterspannung erkannt | 1 |
| 0xE0EC0D | Signal (0x36A) ungültig empfangen: Anzeige Fernlicht Assistent, Anfortderung Bedienung Fernlicht Assistent | 1 |
| 0xE0D405 | Botschaft (0x3a0 , Fahrzeugzustand): Ausfall | 1 |
| 0x02FF5F | Dummy-Fehlerspeichereintrag im Komponentenfehlerbereich nur für Testzwecke | 1 |
| 0xE0EC08 | Signal (0x3b0) ungültig empfangen: Status Gang Rückwärts | 1 |
| 0xE0EC02 | Signal (0x380) ungültig empfangen: Fahrgestellnummer | 1 |
| 0xE0EC07 | Signal (0x330) ungültig empfangen:Wegstrecke Kilometer | 1 |
| 0xE0EC0E | Signal (0x96) ungültig empfangen: eines der Signale Position Hell-Dunkel-Grenze ungültig | 1 |
| 0x800600 | Interner Komponentenfehler Steuergerät | 0 |
| 0xE0EC0C | Signal (0x328) ungültig empfangen: Zeit Sekunde Zähler Relativ | 1 |
| 0xE0D406 | Botschaft (0x1a1 , Geschwindigkeit Fahrzeug): Ausfall | 1 |
| 0xE0EC00 | Signal (0x1ee) ungültig empfangen: Bedienung Lenkstocktaster | 1 |
| 0xE0D408 | Botschaft (0x330 , Kilometerstand Reichweite): Ausfall | 1 |
| 0xE0CBFF | Dummy-Fehlerspeichereintrag im Netzwerkfehlerbereich nur fuer Testzwecke | 1 |
| 0x800601 | Interner Komponentenfehler Kamera | 0 |
| 0xE0D40C | Botschaft (0x328 , Relativzeit): Ausfall | 1 |
| 0xE0D40D | Botschaft (0x36A, Status Fernlichtassistent): Ausfall | 1 |
| 0xFFFFFF | unbekannter Fehlerort | 0 |
FDETAILSTRUKTUR
Dimensions: 6 rows × 2 columns
| NAME | TYP |
|---|---|
| F_UWB_ERW | nein |
| SAE_CODE | nein |
| F_HLZ | nein |
| F_SEVERITY | nein |
| F_UWB_SATZ | 2 |
| F_HLZ_VIEW | - |
IORTTEXTE
Dimensions: 5 rows × 3 columns
| ORT | ORTTEXT | EREIGNIS_DTC |
|---|---|---|
| 0x5F0000 | Infospeicher: Onlinekalibrierung initial abgeschlossen | 0 |
| 0x80060F | Botschaft (328h, Relativzeit): Ausfall | 1 |
| 0x80060D | Puffer für aktive Fehlermeldungen voll. | 0 |
| 0x80060E | Versand aktiver Fehlermeldungen mehrfach erfolglos. Puffer wird gelöscht. | 0 |
| 0xFFFFFF | unbekannter Fehlerort | 0 |
IDETAILSTRUKTUR
Dimensions: 4 rows × 2 columns
| NAME | TYP |
|---|---|
| F_UWB_ERW | nein |
| SAE_CODE | nein |
| F_HLZ | nein |
| F_SEVERITY | nein |
SG_FUNKTIONEN
Dimensions: 13 rows × 16 columns
| ARG | ID | RESULTNAME | INFO | EINHEIT | LABEL | L/H | DATENTYP | NAME | MUL | DIV | ADD | SG_ADR | SERVICE | ARG_TABELLE | RES_TABELLE |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ABSCHALTGRUND_FERNLICHT | 0xD341 | - | Abschaltgründe für Fernlicht. | - | - | - | - | - | - | - | - | - | 22 | - | RES_0xD341 |
| AUTOAIM_FLA_INIT | 0xD370 | - | Status AUTOAIM-Vorgang und aktuelle Werte | - | - | - | - | - | - | - | - | - | 22 | - | RES_0xD370 |
| AIM_OFFSET | 0xD371 | - | Auslesen der horizontalen und vertikalen Offsetwerte. | - | - | - | - | - | - | - | - | - | 22 | - | RES_0xD371 |
| SENSORPARAMETER_FLA | 0xD372 | - | Auslesen diverser Imagerparameter. | - | - | - | - | - | - | - | - | - | 22 | - | RES_0xD372 |
| DEMO_MODE_FLA | 0xD3A6 | - | Demo-Mode für Fernlichtassisten ein-/ausschalten. | - | - | - | - | - | - | - | - | - | 2E | ARG_0xD3A6 | - |
| EMPFEHLUNG_FLA_STFLA | 0xD3AD | - | Empfehlung für 2-stufigen und stufenlosen Fernlichtassisten | - | - | - | - | - | - | - | - | - | 2E;22 | ARG_0xD3AD | RES_0xD3AD |
| OFFSET_AUTOAIM | 0xD3B7 | - | Setzt die Offset-AUTOAIM-Werte auf einen beliebigen Wert | - | - | - | - | - | - | - | - | - | 2E | ARG_0xD3B7 | - |
| _OFFSET_WINDSCREEN | 0xD3B8 | - | Scheibenneigungswinkel | - | - | - | - | - | - | - | - | - | 2E | ARG_0xD3B8 | - |
| SPANNUNG_KLEMME_15N_WERT | 0xDAD2 | STAT_SPANNUNG_KLEMME_15N_WERT | Auslesen der Klemmensteuerung am Steuergerät. | Volt | - | - | int | - | - | 10.0 | - | - | 22 | - | - |
| AUSRICHTUNG_WERK_SCHREIBEN | 0xA375 | - | Die Ausrichtung der Kamera wird mit einem Target durchgeführt | - | - | - | - | - | - | - | - | - | 31 | ARG_0xA375 | RES_0xA375 |
| AUSRICHTUNG_WERK_LESEN | 0xA376 | - | Überprüfung der Ausrichtung mit Target | - | - | - | - | - | - | - | - | - | 31 | ARG_0xA376 | RES_0xA376 |
| _FASTA_FLA_DATA | 0x4001 | - | _FASTA_FLA_DATA | - | - | - | - | - | - | - | - | - | 22 | - | RES_0x4001 |
| _FASTA_FLA_LOESCHEN | 0x4006 | - | _FASTA_FLA_LOESCHEN | - | - | - | - | - | - | - | - | - | 2E | ARG_0x4006 | - |
TAB_INIT
Dimensions: 3 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00 | nicht initialisiert |
| 0x01 | Initialisierung in Ordnung |
| 0xFF | Initialisierung nicht in Ordnung |
TAB_FLA_CONTROL
Dimensions: 4 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00 | AUS |
| 0x01 | EIN |
| 0x02 | keine_Empfehlung |
| 0x03 | Zurück_zum_Normalmodus |
RES_0XD341
Dimensions: 8 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_FLA_ENTGEGENKOMMENDES_FAHRZEUG | 0/1 | - | unsigned char | - | - | - | - | - | Gibt aus, ob ein entgegenkommendes Fahrzeug erkannt worden ist: 0 = kein Fahrzeug erkannt, 1 = Fahrzeug erkannt |
| STAT_FLA_VORAUSFAHRENDES_FAHRZEUG | 0/1 | - | unsigned char | - | - | - | - | - | Gibt aus, ob ein vorausfahrendes Fahrzeug erkannt worden ist: 0 = kein Fahrzeug erkannt, 1 = Fahrzeug erkannt |
| STAT_FLA_GESCHWINDIGKEITSLIMIT | 0/1 | - | unsigned char | - | - | - | - | - | Gibt aus, ob die Geschwindigkeit unterhalb der Grenze erkannt worden ist: 0 = Geschwindigkeit oberhalb der Schwelle, Fernlicht wird eingeschaltet, 1 = Geschwindigkeit unterhalb der Schwelle, Fernlicht wird abgeschaltet |
| STAT_FLA_UMGEBUNGSHELLIGKEIT | 0/1 | - | unsigned char | - | - | - | - | - | Gibt aus, ob Umgebungshelligkeit (Tag) erkannt worden ist: 0 = kein Helligkeit (Nacht) erkannt, 1 = Helligkeit (Tag) erkannt |
| STAT_FLA_ORTSCHAFTSERKENNUNG | 0/1 | - | unsigned char | - | - | - | - | - | Gibt aus, ob eine ausreichende Beleuchtung erkannt worden ist: 0 = keine ausreichende Beleuchtung erkannt, 1 = ausreichende Beleuchtung erkannt |
| STAT_FLA_NEBELERKENNUNG | 0/1 | - | unsigned char | - | - | - | - | - | Gibt aus, ob Nebel erkannt worden ist: 0 = kein Nebel, 1 = Nebel erkannt |
| STAT_FLA_AUTOBAHNMODE | 0/1 | - | unsigned char | - | - | - | - | - | Gibt aus, ob Autobahn erkannt worden ist: 0 = keine Autobahn, 1 = Autobahn erkannt |
| STAT_FLA_VERZOEGERUNGSZEIT | 0/1 | - | unsigned char | - | - | - | - | - | Gibt aus, ob wegen einer Zeiterzögerung das Fernlicht nicht eingeschaltet wird: 0 = keine Zeitverzögerung, 1 = Zeitverzögerung |
RES_0XD370
Dimensions: 4 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_AUTOAIM | 0/1 | - | unsigned char | - | - | - | - | - | Status der initialen Kalibrierung im Kundenbetrieb 0=AUTOAIM nicht abgeschlossen, 1=AUTOAIM initial abgeschlossen |
| STAT_AUTOAIM_OFFSET_H_WERT | Grad | - | char | - | - | - | 10.0 | - | Erfolgte Korrektur horizontal in Grad |
| STAT_AUTOAIM_OFFSET_V_WERT | Grad | - | char | - | - | - | 10.0 | - | Erfolgte Korrektur vertikal in Grad |
| STAT_AUTOAIM_INITIAL_COMPLETION_DISTANCE_WERT | km | high | unsigned long | - | - | - | - | - | Gefahrenen Kilometer bis initiale Kalibrierung, Das Byte 1 wird mit 0 vorbelegt, sodaß der Distanze_Wert vom CAN-Bus übernommen werden kann. |
RES_0XD371
Dimensions: 5 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_SUPPLIER_OFFSET_H_WERT | Grad | - | char | - | - | - | 10.0 | - | Steuergeräte interner H-Offset (Anlieferzustand vom Zulieferer) in 0.1*Grad |
| STAT_SUPPLIER_OFFSET_V_WERT | Grad | - | char | - | - | - | 10.0 | - | Steuergeräte interner V-Offset (Anlieferzustand vom Zulieferer) in Grad |
| STAT_WINDSCREEN_OFFSET_V_WERT | Grad | - | char | - | - | - | 10.0 | - | Durch das Fahrzeug eingebrachte V-Offset in Grad |
| STAT_AUTOAIM_OFFSET_H_WERT | Grad | - | char | - | - | - | 10.0 | - | Erfolgte Korrektur horizontal in Grad |
| STAT_AUTOAIM_OFFSET_V_WERT | Grad | - | char | - | - | - | 10.0 | - | Erfolgte Korrektur vertikal in Grad |
RES_0XD372
Dimensions: 4 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_TEMPERATUR_WERT | °C | - | char | - | - | - | - | - | Temperatur auf dem Imager-Die |
| STAT_IMAGER_MAX_PIXEL_WERT | % | - | unsigned char | - | - | - | - | - | Wert des hellsten Pixels |
| STAT_IMAGER_MIN_PIXEL_WERT | % | - | unsigned char | - | - | - | - | - | Wert des dunkelsten Pixels |
| STAT_IMAGER_AVG_PIXEL_WERT | % | - | unsigned char | - | - | - | - | - | Wert der durchschnittlichen Pixelhelligkeit |
ARG_0XD3A6
Dimensions: 1 rows × 12 columns
| ARG | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|
| AKTION | 0/1 | - | unsigned char | - | - | - | - | - | - | - | 1 = Demo-Mode einschalten, 0 = Demo-Mode ausschalten |
RES_0XD3AD
Dimensions: 5 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_SCHALTEMPFEHLUNG_FLA | 0-n | - | unsigned char | - | TAB_FLA_EMPFEHLUNG | - | - | - | Schaltempfehlung 2-stufiger FLA: 0 = Keine Emfehlung (Defekt erkannt, Sichtfeld verdreckt), 1 = Fernlicht AUS, 2 = Fernlicht EIN |
| STAT_GFA_OBJECT_RANGE_WERT | m | - | unsigned char | - | - | - | - | - | Entfernung zum Objekt |
| STAT_GFA_RIGHT_BOUNDARY_WERT | Grad | - | unsigned char | - | - | 1.0 | 10.0 | -15.0 | Rechte Grenze des blendfreien Bereiches |
| STAT_GFA_LEFT_BOUNDARY_WERT | Grad | - | unsigned char | - | - | 1.0 | 10.0 | -10.4 | Linke Grenze des blendfreien Bereiches |
| STAT_GFA_LOWER_BOUNDARY_WERT | Grad | - | unsigned char | - | - | 1.0 | 20.0 | -5.0 | Untere Grenze des blendfreien Bereichs |
ARG_0XD3AD
Dimensions: 5 rows × 12 columns
| ARG | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|
| SCHALTEMPFEHLUNG_FLA | 0-n | - | unsigned char | - | TAB_STFLA_CONTROL | - | - | - | - | - | Schaltempfehlung für FLA: 0 = Keine Empfehlung 1 = AUS 2 = EIN 3 = Zurück zum Normalbetrieb |
| GFA_OBJECT_RANGE | m | - | unsigned char | - | - | - | - | - | - | - | Auszugebende Entfernung zum Objekt |
| GFA_RIGHT_BOUNDARY | Grad | - | unsigned char | - | - | 10.0 | 1.0 | 150.0 | -15.0 | 10.4 | Auszugebende rechte Grenze in 0,1 Grad-Schritten des blendfreien Bereiches |
| GFA_LEFT_BOUNDARY | Grad | - | unsigned char | - | - | 10.0 | 1.0 | 104.0 | -10.4 | 15.0 | Auszugebende linke Grenze in 0,1 Grad-Schritten des blendfreien Bereiches |
| GFA_LOWER_BOUNDARY | Grad | - | unsigned char | - | - | 20.0 | 1.0 | 100.0 | -5.0 | 5.0 | Auszugebende untere Grenze in 0,05 Schritten des blendfreien Bereichs |
TAB_STFLA_CONTROL
Dimensions: 4 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00 | Keine_Empfehlung |
| 0x01 | AUS |
| 0x02 | EIN |
| 0x03 | Zurück_zum_Normalbetrieb |
TAB_FLA_EMPFEHLUNG
Dimensions: 4 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x0000 | Keine Empfehlung |
| 0x0001 | Fernlicht AUS |
| 0x0002 | Fernlicht EIN |
| 0xFFFF | Ungültig |
ARG_0XD3B7
Dimensions: 2 rows × 12 columns
| ARG | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|
| RESET_AXIS | 0-n | - | unsigned char | - | TAB_FLA_AXIS | - | - | - | - | - | Angabe der Achse |
| OFFSET_ANGLE | Grad | - | char | - | - | 10.0 | - | - | -3.5 | 3.5 | Winkel mit 1 Nachkommastellen |
TAB_FLA_AXIS
Dimensions: 2 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x01 | H |
| 0x02 | V |
ARG_0XD3B8
Dimensions: 1 rows × 12 columns
| ARG | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|
| OFFSET_ANGLE_V | Grad | - | char | - | - | 10.0 | - | - | -3.5 | 3.5 | Winkel für Scheibenoffset mit 1 Nachkommastelle |
RES_0XA375
Dimensions: 3 rows × 13 columns
| RESULTNAME | STR | STPR | RRR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| STAT_AIM_RESULT | - | - | + | 0-n | - | unsigned char | - | TAB_FLA_AIM_RESULT | - | - | - | Rückgabe des Status des Ausrichtungstests im Werk. |
| STAT_AUTOAIM_OFFSET_H_WERT | - | - | + | Grad | - | char | - | - | - | 10.0 | - | Erfolgte Korrektur horizontal in Grad |
| STAT_AUTOAIM_OFFSET_V_WERT | - | - | + | Grad | - | char | - | - | - | 10.0 | - | Erfolgte Korrektur vertikal in Grad |
ARG_0XA375
Dimensions: 3 rows × 14 columns
| ARG | STR | STPR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| H_DEV | + | - | Grad | - | char | - | - | 10.0 | - | - | -12.8 | 12.7 | Horizontale Fehlpositionierung des Targets zur FLA-Mitte (= Fahrzeugmitte) in Grad |
| V_DEV | + | - | Grad | - | char | - | - | 10.0 | - | - | -12.8 | 12.7 | Vertikale Fehlpositionierung des Targets zur FLA-Mitte (= Fahrzeugmitte) in Grad |
| AIM_AXIS | + | - | 0-n | - | unsigned char | - | TAB_FLA_AXIS_HV | - | - | - | - | - | Zu berücksichtigende Achse (H,V,HV) |
RES_0XA376
Dimensions: 6 rows × 13 columns
| RESULTNAME | STR | STPR | RRR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| STAT_AIM_RESULT | - | - | + | 0-n | - | unsigned char | - | TAB_FLA_AIM_RESULT | - | - | - | Rückgabe des Status des Ausrichtungstests im Werk. |
| STAT_AUTOAIM_OFFSET_H_WERT | - | - | + | Grad | - | char | - | - | - | 10.0 | - | Erfolgte Korrektur horizontal in Grad |
| STAT_AUTOAIM_OFFSET_V_WERT | - | - | + | Grad | - | char | - | - | - | 10.0 | - | Erfolgte Korrektur vertikal in Grad |
| STAT_SUPPLIER_OFFSET_H_WERT | - | - | + | Grad | - | char | - | - | - | 10.0 | - | Steuergeräte interner H-Offset (Anlieferzustand vom Zulieferer) in 0.1*Grad |
| STAT_SUPPLIER_OFFSET_V_WERT | - | - | + | Grad | - | char | - | - | - | 10.0 | - | Steuergeräte interner V-Offset (Anlieferzustand vom Zulieferer) in Grad |
| STAT_WINDSCREEN_OFFSET_V_WERT | - | - | + | Grad | - | char | - | - | - | 10.0 | - | Durch das Fahrzeug eingebrachte V-Offset in Grad |
ARG_0XA376
Dimensions: 3 rows × 14 columns
| ARG | STR | STPR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| H_DEV | + | - | Grad | - | char | - | - | 10.0 | - | - | -12.8 | 12.7 | Horizontale Fehlpositionierung des Targets zur FLA-Mitte (= Fahrzeugmitte) in Grad |
| V_DEV | + | - | Grad | - | char | - | - | 10.0 | - | - | -12.8 | 12.7 | Vertikale Fehlpositionierung des Targets zur FLA-Mitte (= Fahrzeugmitte) in Grad |
| AIM_AXIS | + | - | 0-n | - | unsigned char | - | TAB_FLA_AXIS_HV | - | - | - | - | - | Zu berücksichtigende Achse (H,V,HV) |
TAB_FLA_AIM_RESULT
Dimensions: 6 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00 | Aiming OK |
| 0x01 | Aiming-Error: Target not found |
| 0x02 | Aiming-Error: Ambient to bright |
| 0x03 | Aiming-Error: Out off range |
| 0x04 | Aiming-Error: Too many light sources |
| 0x05 | Aiming-Error: Out off tolerance |
TAB_FLA_AXIS_HV
Dimensions: 3 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x01 | H |
| 0x02 | V |
| 0x03 | HV |
RES_0X4001
Dimensions: 6 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_FLA_OP_TIME_WERT | s | high | unsigned long | - | - | - | - | - | Zeitdauer FLA durch Fahrer aktiviert [s] |
| STAT_DELTA_TIME_FLA_NIGHT_WERT | s | high | unsigned long | - | - | - | - | - | Zeitdauer in der Umgebungshelligkeit FLA Aktivierung erlaubt [s] |
| STAT_DELTA_TIME_FLA_ACT_HB_WERT | s | high | unsigned long | - | - | - | - | - | Zeitdauer Einschaltempfehlung FLA [s] |
| STAT_DELTA_TIME_FLA_ACT_LB_WERT | s | high | unsigned long | - | - | - | - | - | Zeitdauer Abschaltempfehlung [s] |
| STAT_FLA_COUNT_OVERRIDE_WERT | Counts | high | unsigned long | - | - | - | - | - | Anzahl Übersteuerung durch Fahrer |
| STAT_OPTIME_TOTAL_WERT | s | high | unsigned long | - | - | - | - | - | Absoluter Betriebszeitzähler [s] |
ARG_0X4006
Dimensions: 1 rows × 12 columns
| ARG | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|
| FASTA_FLA_LOESCHEN | 0/1 | high | char | - | - | - | - | - | - | - | 1 = FASTA-Daten löschen |