gzar01.prg
INFO
| Field | Value |
|---|---|
| ECU | - |
| ORIGIN | BMW EK-532 MarioWerkstetter |
| REVISION | 1.510 |
| AUTHOR | APAG CTO FrankDoorenbosch, APAG FE TillFriedrich |
| COMMENT | - |
| PACKAGE | 1.25 |
| SPRACHE | deutsch |
Jobs
Index
- INFO - Information SGBD
- INITIALISIERUNG - Initialisierung und Kommunikationsparameter
- IDENT - Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
- FS_LESEN - Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
- FS_LESEN_DETAIL - Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
- FS_LOESCHEN - Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
- PRUEFSTEMPEL_LESEN - Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
- PRUEFSTEMPEL_SCHREIBEN - Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
- SVK_LESEN - Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
- STATUS_LESEN - Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
- STEUERN - Vorgeben eines Status UDS : $2E WriteDataByIdentifier
- SERIENNUMMER_LESEN - Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
- STEUERN_IO - Vorgeben eines Status UDS : $2F InputOutputControlByIdentifier
- STEUERN_ROUTINE - Vorgeben eines Status UDS : $31 RoutineControl
- FS_SPERREN - Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
- FS_LESEN_PERMANENT - permanente Fehler aus Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $15 ReportDTCWithPermanentStatus Modus: Default
- IS_LESEN - Sekundaerer Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $22 ReadDataByIdentifierRequestServiceID UDS : $2000 DataIdentifier sekundaerer Fehlerspeicher Modus: Default
- IS_LESEN_DETAIL - sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $22 ReadDataByIdentifier UDS : $20 dataIdentifier UDS : $00 alle Info-Meldungen anschließend UDS : $20 dataIdentifier UDS : $nn Details zur Info-Meldung an der Position n Modus: Default
- IS_LOESCHEN - Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default
- STATUS_BLOCK_LESEN - Lesen eines dynamisch definierten Datenblockes UDS : $2C DynamicallyDefineDataIdentifier $03 ClearDynamicallyDefinedDataIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier UDS : $2C DynamicallyDefineDataIdentifier $01 DefineByIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier UDS : $22 ReadDataByIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier $2C$02 DefineByMemoryAddress wird nicht unterstützt 'Composite data blocks' werden nur komplett unterstützt
- HERSTELLINFO_LESEN - Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
- DIAGNOSE_AUFRECHT - Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
- DIAGNOSE_MODE - SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
- SLEEP_MODE - SG in Sleep-Mode versetzen UDS : $11 ECUReset UDS : $04 EnableRapidPowerShutDown Modus: Default
- ENERGIESPARMODE - Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
- STATUS_ENERGIESPARMODE - Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
- STATUS_BETRIEBSMODE - Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default
- STEUERN_BETRIEBSMODE - Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default
- SENSOREN_ANZAHL_LESEN - Anzahl der intelligenten Subbussensoren lesen UDS : $22 ReadDataByIdentifier UDS : $1600 Identifier NumberofSubbusMembers Modus: Default
- SENSOREN_IDENT_LESEN - Identifikation der intelligenten Subbussensoren lesen UDS : $22 ReadDataByIdentifier UDS : $1600 Identifier NumberofSubbusMembers UDS : $16xx SubbusMemberSerialNumber Modus: Default
- STEUERGERAETE_RESET - Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
- STEUERN_ROE_STOP - Temporaeres Deaktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $00 Stop $02 (EventWindowTime)
- STATUS_ROE_REPORT - Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS: $86 ResponseOnEvent $04 report activated events [$02 eventWindowTime - infinite (nur 35up)]
- STEUERN_ROE_START - Temporaeres Aktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $05 Start $02 (EventWindowTime)
- STEUERN_ROE_PERSISTENT_STOP - Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime)
- STEUERN_ROE_PERSISTENT_START - Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime)
- CPS_LESEN - Codierpruefstempel lesen UDS : $22 ReadDataByIdentifier UDS : $37FE DataIdentifier Codierpruefstempel Modus: Default
- DIAG_SESSION_LESEN - Aktive Diagnose-Session auslesen UDS : $22 ReadDataByIdentifier UDS : $F186 ActiveDiagnosticSession Modus: Default
- FLASH_TP_LESEN - Flash Timing Parameter auslesen UDS : $22 ReadDataByIdentifier UDS : $2504 FlashTimingParameter Modus: Default
- PROG_ZAEHLER_LESEN - Programmierzaehler lesen UDS : $22 ReadDataByIdentifier UDS : $2502 ProgrammingCounter Modus: Default
- PROG_MAX_LESEN - Anzahl der maximal möglichen Programmiervorgänge auslesen UDS : $22 ReadDataByIdentifier UDS : $2503 ProgrammingCounter Modus: Default
INFO
Information SGBD
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| ECU | string | Steuergerät im Klartext |
| ORIGIN | string | Steuergeräte-Verantwortlicher |
| REVISION | string | Versions-Nummer |
| AUTHOR | string | Namen aller Autoren |
| COMMENT | string | wichtige Hinweise |
| PACKAGE | string | Include-Paket-Nummer |
| SPRACHE | string | deutsch, english |
INITIALISIERUNG
Initialisierung und Kommunikationsparameter
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| DONE | int | 1, wenn Okay |
IDENT
Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| ID_SG_ADR | long | Steuergeraeteadresse |
| ID_SGBD_INDEX | long | Index zur Erkennung der SG-Variante |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FS_LESEN
Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FS_LESEN_DETAIL
Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| F_CODE | long | gewaehlter Fehlercode |
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_HFK | int | Haufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf |
| F_HLZ | int | Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Haufigkeitszaehler |
| F_UEBERLAUF | int | 0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers |
| F_FEHLERKLASSE_NR | int | 0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich ! |
| F_FEHLERKLASSE_TEXT | string | Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT |
| F_UW_ANZ | int | Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung |
| F_UW_KM | long | Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht |
| F_UW_ZEIT | long | Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_SAE_CODE | unsigned int | Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD |
| F_SAE_CODE_STRING | string | 5 stelliger Text in der Form 'Sxxxx' |
| F_SAE_CODE_TEXT | string | Text zu F_SAE_CODE |
| _RESPONSE_SNAPSHOT | binary | Hex-Antwort von SG |
| _RESPONSE_EXTENDED_DATA | binary | Hex-Antwort von SG |
| _RESPONSE_SEVERITY | binary | Hex-Antwort von SG |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
FS_LOESCHEN
Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| F_CODE | long | 0x??????: Angabe eines einzelnen Fehlers Default: 0xFFFFFF: alle Fehler |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PRUEFSTEMPEL_LESEN
Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| BYTE1 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE2 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE3 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PRUEFSTEMPEL_SCHREIBEN
Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| BYTE1 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE2 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE3 | int | Bereich: 0-255 bzw. 0x00-0xFF |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
SVK_LESEN
Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| SVK | string | table SVK_ID BEZEICHNUNG WERT default SVK_AKTUELL |
Results
| Name | Type | Comment |
|---|---|---|
| PROG_TEST | int | Programmierabhaengigkeiten (ProgrammingDependenciesChecked) 1: IO : Signaturpruefung und ProgrammingDependenciesCheck erfolgreich 2: NIO: mindestens eine SWE fehlerhaft oder ProgrammingDependenciesCheck nicht durchgefuehrt 3: NIO: mindestens eine SWE passt nicht mit einer HWE zusammen 4: NIO: mindestens eine SWE passt nicht mit einer anderen SWE zusammen sonst: reserviert |
| ANZAHL_EINHEITEN | int | Anzahl der xWEn |
| PROG_DATUM | string | Programmierdatum (DD.MM.YY) |
| PROG_KM | long | KM-Stand bei Programmierung (10 KM bis 655350 KM) Inkrement sind 10 KM -1: KM-Stand wird nicht unterstuetzt |
| PROZESSKLASSE_WERT | int | table Prozessklassen WERT dezimale Angabe der Prozessklasse |
| PROZESSKLASSE_TEXT | string | table Prozessklassen BEZEICHNUNG Text-Angabe der Prozessklasse |
| PROZESSKLASSE_KURZTEXT | string | table Prozessklassen PROZESSKLASSE Text-Angabe des Prozessklassenkurztextes |
| SGBM_IDENTIFIER | string | Angabe SGBM-ID der Prozessklasse |
| VERSION | string | Angabe der Version der Prozessklasse |
| SGBM_ID | string | Angabe von Prozessklasse, SGBM-Identifier, Version |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_LESEN
Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Es muss mindestens ein Argument übergeben werden Es wird das zugehörige result erzeugt table SG_Funktionen ARG ID RESULTNAME RES_TABELLE ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN
Vorgeben eines Status UDS : $2E WriteDataByIdentifier
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Siehe table SG_Funktionen ARG ID LABEL ARG_TABELLE |
| WERT | string | Es muss mindestens ein Argument übergeben werden Argumente siehe table SG_Funktionen ARG ID ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
SERIENNUMMER_LESEN
Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| SERIENNUMMER | string | Seriennummer des Steuergeraets |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_IO
Vorgeben eines Status UDS : $2F InputOutputControlByIdentifier
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Siehe table SG_Funktionen ARG ID RES_TABELLE ARG_TABELLE |
| STEUERPARAMETER | string | 'RCTECU' = returnControlToECU 'RTD' = resetToDefault 'FCS' = freezeCurrentState 'STA' = shortTermAdjustment optionales Argument Wenn nicht angegeben, dann kein InputOutputControlParameter im Request |
| WERT | string | Argumente siehe table SG_Funktionen ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROUTINE
Vorgeben eines Status UDS : $31 RoutineControl
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Siehe table SG_Funktionen ARG ID RES_TABELLE ARG_TABELLE |
| STEUERPARAMETER | string | 'STR' = startRoutine 'STPR' = stopRoutine 'RRR' = requestRoutineResults |
| WERT | string | Argumente siehe table SG_Funktionen ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FS_SPERREN
Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| SPERREN | string | "ja" -> Fehlerspeicher sperren "nein" -> Fehlerspeicher freigeben table DigitalArgument TEXT Default: "ja" |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FS_LESEN_PERMANENT
permanente Fehler aus Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $15 ReportDTCWithPermanentStatus Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
IS_LESEN
Sekundaerer Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $22 ReadDataByIdentifierRequestServiceID UDS : $2000 DataIdentifier sekundaerer Fehlerspeicher Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
IS_LESEN_DETAIL
sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $22 ReadDataByIdentifier UDS : $20 dataIdentifier UDS : $00 alle Info-Meldungen anschließend UDS : $20 dataIdentifier UDS : $nn Details zur Info-Meldung an der Position n Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| F_CODE | long | gewaehlter Infocode Wenn dieser Parameter angegeben wird, wird die Position automatisch ermittelt. Es darf dann nicht argument F_POS angegeben werden |
| F_POS | int | gewaehlter Eintrag Wenn dieser Parameter angegeben wird, wird die Position benutzt. Wertebereich 1 - 255 Es darf dann nicht argument F_CODE angegeben werden |
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_HFK | int | Haufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf |
| F_HLZ | int | Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Haufigkeitszaehler |
| F_UEBERLAUF | int | 0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers |
| F_FEHLERKLASSE_NR | int | 0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich ! |
| F_FEHLERKLASSE_TEXT | string | Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT |
| F_UW_ANZ | int | Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung |
| F_UW_KM | long | Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht |
| F_UW_ZEIT | long | Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_SAE_CODE | unsigned int | Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD |
| F_SAE_CODE_STRING | string | 5 stelliger Text in der Form 'Sxxxx' |
| F_SAE_CODE_TEXT | string | Text zu F_SAE_CODE |
| _RESPONSE_2000 | binary | Hex-Antwort von SG |
| _RESPONSE_200X | binary | Hex-Antwort von SG |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
IS_LOESCHEN
Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_BLOCK_LESEN
Lesen eines dynamisch definierten Datenblockes UDS : $2C DynamicallyDefineDataIdentifier $03 ClearDynamicallyDefinedDataIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier UDS : $2C DynamicallyDefineDataIdentifier $01 DefineByIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier UDS : $22 ReadDataByIdentifier $F300-$F3FF DynamicallyDefinedDataIdentifier $2C$02 DefineByMemoryAddress wird nicht unterstützt 'Composite data blocks' werden nur komplett unterstützt
Arguments
| Name | Type | Comment |
|---|---|---|
| BLOCK_NR | long | Nummer des Blockes 0..255 |
| NEU_DEFINIEREN | string | Wenn 'JA' oder 'YES' wird der Block im SG gelöscht und neu ins SG geschrieben Wenn 'NEIN' oder 'NO' wird der Block im SG nicht gelöscht und nicht geschrieben Anschließend wird der Block gelesen |
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Es muss mindestens ein Argument übergeben werden Es wird das zugehörige Result table SG_Funktionen ARG ID RESULTNAME erzeugt |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST_1 | binary | Hex-Antwort von SG |
| _RESPONSE_1 | binary | Hex-Antwort von SG |
| _REQUEST_2 | binary | Hex-Antwort von SG |
| _RESPONSE_2 | binary | Hex-Antwort von SG |
| _REQUEST_3 | binary | Hex-Antwort von SG |
| _RESPONSE_3 | binary | Hex-Antwort von SG |
HERSTELLINFO_LESEN
Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| ID_LIEF_NR | long | Lieferantennummer 0xFFFFFF, falls nicht vorhanden |
| ID_LIEF_TEXT | string | Text zu ID_LIEF_NR table Lieferanten LIEF_TEXT unbekannter Hersteller, falls nicht vorhanden |
| ID_DATUM | string | Herstelldatum (DD.MM.YY) |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
| _REQUEST_2 | binary | Hex-Auftrag an SG |
| _RESPONSE_2 | binary | Hex-Antwort von SG |
DIAGNOSE_AUFRECHT
Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| SG_ANTWORT | string | "ja" -> SG soll antworten "nein" -> SG soll nicht antworten table DigitalArgument TEXT Default: SG soll antworten |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
DIAGNOSE_MODE
SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
Arguments
| Name | Type | Comment |
|---|---|---|
| MODE | string | gewuenschter Diagnose-Modus table DiagMode MODE MODE_TEXT Defaultwert: DEFAULT (DefaultMode) |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
SLEEP_MODE
SG in Sleep-Mode versetzen UDS : $11 ECUReset UDS : $04 EnableRapidPowerShutDown Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
ENERGIESPARMODE
Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
Arguments
| Name | Type | Comment |
|---|---|---|
| MODE | int | 0x00: Normalmode 0x01: Fertigungsmode 0x02: Transportmode 0x03: Flashmode |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_ENERGIESPARMODE
Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_ENERGIESPARMODE_WERT | int | Ausgabe des Energiesparmodes 0: Kein Energiesparmode gesetzt 1: Produktionsmode gesetzt 2: Transportmode gesetzt 3: Flashmode gesetzt -1: Mode ungueltig |
| STAT_ENERGIESPARMODE_TEXT | string | Text zu STAT_ENERGIESPARMODE_WERT |
| STAT_PRODUKTIONSMODE_EIN | int | 0: Produktionsmode nicht aktiv 1: Produktionsmode aktiv |
| STAT_TRANSPORTMODE_EIN | int | 0: Transportmode nicht aktiv 1: Transportmode aktiv |
| STAT_FLASHMODE_EIN | int | 0: Flashmode nicht aktiv 1: Flashmode aktiv |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_BETRIEBSMODE
Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_BETRIEBSMODE_WERT | int | Aktueller Betriebsmode table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle) |
| STAT_BETRIEBSMODE_TEXT | string | Textausgabe STAT_BETRIEBSMODE_WERT table Betriebsmode TEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_BETRIEBSMODE
Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| BETRIEBSMODE | int | Betriebsmode setzen table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle) |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
SENSOREN_ANZAHL_LESEN
Anzahl der intelligenten Subbussensoren lesen UDS : $22 ReadDataByIdentifier UDS : $1600 Identifier NumberofSubbusMembers Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| SENSOR_ANZAHL | long | Anzahl der intelligenten Subbussensoren |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
SENSOREN_IDENT_LESEN
Identifikation der intelligenten Subbussensoren lesen UDS : $22 ReadDataByIdentifier UDS : $1600 Identifier NumberofSubbusMembers UDS : $16xx SubbusMemberSerialNumber Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| SENSOR_NR | long | optionales Argument gewuenschter Sensor xx (0x01 - 0xFF) oder VERBAUORT eines bestimmten Sensors (table VerbauortTabelle ORT) |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| SENSOR_VERBAUORT | string | Verbauort des Sensors table VerbauortTabelle ORTTEXT |
| SENSOR_VERBAUORT_NR | long | Verbauort-Nummer des Sensors |
| SENSOR_BMW_NR | string | BMW-Teilenummer des Sensors |
| SENSOR_PART_NR | string | Teilenummer des Sensors optional wenn SENSOR_BMW_NR gueltig wenn Teilenummer vom Sensor nicht verfuegbar dann '--' |
| SENSOR_LIN_2_0_FORMAT | int | 1: Die optionalen Daten des Sensors (Hersteller, Seriennummer, ...) werden in LIN_2_Format geliefert 0: Optionale Daten nicht im LIN_2_Format (nur Defaultwerte werden ausgegeben) |
| SENSOR_HERSTELLER_NR | long | Lieferantennummer des Herstellers wenn Hersteller-Nummer nicht verfuegbar, dann 0 |
| SENSOR_HERSTELLER_TEXT | string | Textausgabe Lieferant wenn Softwarestand nicht verfuegbar, dann 'Information nicht verfuegbar' |
| SENSOR_FUNKTIONS_NR | long | Funktionsnummer des Sensors wenn Funktions-Nummer nicht verfuegbar, dann 0 |
| SENSOR_VARIANTEN_NR | long | Variantennummer des Sensors wenn Varianten-Nummer nicht verfuegbar, dann 0 |
| SENSOR_PROD_DATUM | string | Produnktionsdatum (DD.MM.YY) des Sensors wenn Produktions-Datum nicht verfuegbar, dann '--' |
| SENSOR_SERIEN_NR | string | Seriennummer des Sensors wenn Serien-Nummer nicht verfuegbar, dann '--' |
| SENSOR_SW_RELEASE_NR | string | Softwarestand des Sensors wenn Softwarestand nicht verfuegbar, dann '--' |
| SENSOR_HW_RELEASE_NR | string | Hardwarestand des Sensors wenn Softwarestand nicht verfuegbar, dann '--' |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
| _REQUEST_2 | binary | Hex-Auftrag an SG |
| _RESPONSE_2 | binary | Hex-Antwort von SG |
STEUERGERAETE_RESET
Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_STOP
Temporaeres Deaktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $00 Stop $02 (EventWindowTime)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_ROE_REPORT
Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS: $86 ResponseOnEvent $04 report activated events [$02 eventWindowTime - infinite (nur 35up)]
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_ROE_AKTIV | char | 0x00 = Aktive Fehlermeldung deaktiviert 0x01 = Aktive Fehlermeldung aktiviert 0xFF = Status der aktiven Fehlermeldung nicht feststellbar |
| STAT_ROE_AKTIV_TEXT | string | Interpretation von STAT_ROE_AKTIV table UDS_TAB_ROE_AKTIV TEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_START
Temporaeres Aktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $05 Start $02 (EventWindowTime)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_PERSISTENT_STOP
Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_PERSISTENT_START
Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
CPS_LESEN
Codierpruefstempel lesen UDS : $22 ReadDataByIdentifier UDS : $37FE DataIdentifier Codierpruefstempel Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| CPS | string | Codierpruefstempel 7-stellig |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
DIAG_SESSION_LESEN
Aktive Diagnose-Session auslesen UDS : $22 ReadDataByIdentifier UDS : $F186 ActiveDiagnosticSession Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| DIAG_SESSION_WERT | int | Diagnose-Session (1 Byte) |
| DIAG_SESSION_TEXT | string | Diagnose-Session als Text |
| DIAG_DETAIL_WERT | int | Details zur Diagnose-Session (1 Byte) |
| DIAG_DETAIL_TEXT | string | Details zur Diagnose-Session als Text |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FLASH_TP_LESEN
Flash Timing Parameter auslesen UDS : $22 ReadDataByIdentifier UDS : $2504 FlashTimingParameter Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| FLASH_LOESCHEN | int | EraseMemoryTime (2 Byte) |
| FLASH_TEST | int | CheckMemoryTime (2 Byte) |
| FLASH_BOOT | int | BootloaderInstallationTime (2 Byte) |
| FLASH_AUTHENT | int | AuthenticationTime (2 Byte) |
| FLASH_RESET | int | ResetTime (2 Byte) |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PROG_ZAEHLER_LESEN
Programmierzaehler lesen UDS : $22 ReadDataByIdentifier UDS : $2502 ProgrammingCounter Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| PROG_ZAEHLER_STATUS_WERT | int | Status, wie oft das SG programmierbar ist |
| PROG_ZAEHLER_STATUS_TEXT | string | Status, wie oft das SG programmierbar ist |
| PROG_ZAEHLER | int | Programmierzaehler |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PROG_MAX_LESEN
Anzahl der maximal möglichen Programmiervorgänge auslesen UDS : $22 ReadDataByIdentifier UDS : $2503 ProgrammingCounter Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| PROG_MAX | long | maximal mögliche Programmiervorgänge Sonderfall 0xFFFF: Anzahl der Programmiervorgänge unbegrenzt |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
Tables
Index
- JOBRESULT (66 × 2)
- LIEFERANTEN (127 × 2)
- FARTTEXTE (19 × 2)
- DIGITALARGUMENT (17 × 2)
- PROZESSKLASSEN (25 × 3)
- SVK_ID (65 × 2)
- DTCEXTENDEDDATARECORDNUMBER (5 × 3)
- DTCSNAPSHOTIDENTIFIER (5 × 9)
- FEHLERKLASSE (5 × 2)
- DIAGMODE (11 × 3)
- VERBAUORTTABELLE (176 × 3)
- PARTNRTABELLE (1 × 3)
- LIEFERANTENLIN (99 × 2)
- IARTTEXTE (18 × 2)
- UDS_TAB_ROE_AKTIV (3 × 2)
- JOBRESULTEXTENDED (1 × 2)
- BETRIEBSMODE (6 × 3)
- FORTTEXTE (23 × 3)
- FDETAILSTRUKTUR (6 × 2)
- DTCBEREICHE (20 × 4)
- FUMWELTTEXTE (2 × 9)
- IORTTEXTE (14 × 3)
- IDETAILSTRUKTUR (4 × 2)
- IUMWELTTEXTE (2 × 9)
- SG_FUNKTIONEN (13 × 16)
- DM_TAB_ROE_ACTIVATED_DOP (2 × 2)
- RDTCI_LEV_DOP (9 × 2)
- FEHLERKLASSE_DOP (4 × 2)
- PROG_DEP_DOP (6 × 2)
- SVK_VERSION_DOP (2 × 2)
- ENERGIESPARMODE_DOP (4 × 2)
- RDBI_ADS_DOP (8 × 2)
- RDBI_PC_PCS_DOP (3 × 2)
- EXTENDED_ENERGY_MODE_DOP (16 × 2)
- ARG_0XD5D9 (2 × 12)
- ARG_0XD5E3 (1 × 12)
- ARG_0XD5E7 (3 × 12)
- ARG_0XD62F (2 × 12)
- RES_0XA537 (4 × 13)
- RES_0XD5D9 (1 × 10)
- RES_0XD5E3 (1 × 10)
- RES_0XD5E7 (4 × 10)
- ARG_0X4000 (1 × 12)
- ARG_0X4001 (1 × 12)
- ARG_0X4002 (1 × 12)
- RES_0X4001 (1 × 10)
- RES_0X4002 (1 × 10)
- TAB_GZA_LED (4 × 2)
- DL_BINCLASS_HELLIGKEIT (3 × 2)
- SL_BINCLASS_HELLIGKEIT (4 × 2)
- TAB_GZA_REFERENZLAUF (5 × 2)
JOBRESULT
Dimensions: 66 rows × 2 columns
| SB | STATUS_TEXT |
|---|---|
| 0x10 | ERROR_ECU_GENERAL_REJECT |
| 0x11 | ERROR_ECU_SERVICE_NOT_SUPPORTED |
| 0x12 | ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED |
| 0x13 | ERROR_ECU_INCORRECT_MESSAGE_LENGTH_OR_INVALID_FORMAT |
| 0x14 | ERROR_ECU_RESPONSE_TOO_LONG |
| 0x21 | ERROR_ECU_BUSY_REPEAT_REQUEST |
| 0x22 | ERROR_ECU_CONDITIONS_NOT_CORRECT |
| 0x24 | ERROR_ECU_REQUEST_SEQUENCE_ERROR |
| 0x25 | ERROR_ECU_NO_RESPONSE_FROM_SUBNET_COMPONENT |
| 0x26 | ERROR_ECU_FAILURE_PREVENTS_EXECUTION_OF_REQUESTED_ACTION |
| 0x31 | ERROR_ECU_REQUEST_OUT_OF_RANGE |
| 0x33 | ERROR_ECU_SECURITY_ACCESS_DENIED |
| 0x35 | ERROR_ECU_INVALID_KEY |
| 0x36 | ERROR_ECU_EXCEED_NUMBER_OF_ATTEMPTS |
| 0x37 | ERROR_ECU_REQUIRED_TIME_DELAY_NOT_EXPIRED |
| 0x70 | ERROR_ECU_UPLOAD_DOWNLOAD_NOT_ACCEPTED |
| 0x71 | ERROR_ECU_TRANSFER_DATA_SUSPENDED |
| 0x72 | ERROR_ECU_GENERAL_PROGRAMMING_FAILURE |
| 0x73 | ERROR_ECU_WRONG_BLOCK_SEQUENCE_COUNTER |
| 0x78 | ERROR_ECU_REQUEST_CORRECTLY_RECEIVED__RESPONSE_PENDING |
| 0x7E | ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED_IN_ACTIVE_SESSION |
| 0x7F | ERROR_ECU_SERVICE_NOT_SUPPORTED_IN_ACTIVE_SESSION |
| 0x81 | ERROR_ECU_RPM_TOO_HIGH |
| 0x82 | ERROR_ECU_RPM_TOO_LOW |
| 0x83 | ERROR_ECU_ENGINE_IS_RUNNING |
| 0x84 | ERROR_ECU_ENGINE_IS_NOT_RUNNING |
| 0x85 | ERROR_ECU_ENGINE_RUN_TIME_TOO_LOW |
| 0x86 | ERROR_ECU_TEMPERATURE_TOO_HIGH |
| 0x87 | ERROR_ECU_TEMPERATURE_TOO_LOW |
| 0x88 | ERROR_ECU_VEHICLE_SPEED_TOO_HIGH |
| 0x89 | ERROR_ECU_VEHICLE_SPEED_TOO_LOW |
| 0x8A | ERROR_ECU_THROTTLE_PEDAL_TOO_HIGH |
| 0x8B | ERROR_ECU_THROTTLE_PEDAL_TOO_LOW |
| 0x8C | ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_NEUTRAL |
| 0x8D | ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_GEAR |
| 0x8F | ERROR_ECU_BRAKE_SWITCH_NOT_CLOSED |
| 0x90 | ERROR_ECU_SHIFTER_LEVER_NOT_IN_PARK |
| 0x91 | ERROR_ECU_TORQUE_CONVERTER_CLUTCH_LOCKED |
| 0x92 | ERROR_ECU_VOLTAGE_TOO_HIGH |
| 0x93 | ERROR_ECU_VOLTAGE_TOO_LOW |
| ?00? | OKAY |
| ?01? | ERROR_ECU_NO_RESPONSE |
| ?02? | ERROR_ECU_INCORRECT_LEN |
| ?03? | ERROR_ECU_INCORRECT_RESPONSE_ID |
| ?04? | ERROR_ECU_TA_RESPONSE_NOT_SA_REQUEST |
| ?05? | ERROR_ECU_SA_RESPONSE_NOT_TA_REQUEST |
| ?06? | ERROR_ECU_RESPONSE_INCORRECT_DATA_IDENTIFIER |
| ?07? | ERROR_ECU_RESPONSE_TOO_MUCH_DATA |
| ?08? | ERROR_ECU_RESPONSE_TOO_LESS_DATA |
| ?09? | ERROR_ECU_RESPONSE_VALUE_OUT_OF_RANGE |
| ?0A? | ERROR_TABLE |
| ?10? | ERROR_F_CODE |
| ?12? | ERROR_INTERPRETATION |
| ?13? | ERROR_F_POS |
| ?14? | ERROR_ECU_RESPONSE_INCORRECT_IO_CONTROL_PARAMETER |
| ?15? | ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_CONTROL_TYPE |
| ?16? | ERROR_ECU_RESPONSE_INCORRECT_SUB_FUNCTION |
| ?17? | ERROR_ECU_RESPONSE_INCORRECT_DYNAMICALLY_DEFINED_DATA_IDENTIFIER |
| ?18? | ERROR_ECU_RESPONSE_NO_STRING_END_CHAR |
| ?50? | ERROR_BYTE1 |
| ?51? | ERROR_BYTE2 |
| ?52? | ERROR_BYTE3 |
| ?80? | ERROR_SVK_INCORRECT_LEN |
| ?81? | ERROR_SVK_INCORRECT_FINGERPRINT |
| ?F0? | ERROR_ARGUMENT |
| 0xXY | ERROR_ECU_UNKNOWN_NEGATIVE_RESPONSE |
LIEFERANTEN
Dimensions: 127 rows × 2 columns
| LIEF_NR | LIEF_TEXT |
|---|---|
| 0x000001 | Reinshagen => Delphi |
| 0x000002 | Kostal |
| 0x000003 | Hella |
| 0x000004 | Siemens |
| 0x000005 | Eaton |
| 0x000006 | UTA |
| 0x000007 | Helbako |
| 0x000008 | Bosch |
| 0x000009 | Loewe => Lear |
| 0x000010 | VDO |
| 0x000011 | Valeo |
| 0x000012 | MBB |
| 0x000013 | Kammerer |
| 0x000014 | SWF |
| 0x000015 | Blaupunkt |
| 0x000016 | Philips |
| 0x000017 | Alpine |
| 0x000018 | Continental Teves |
| 0x000019 | Elektromatik Suedafrika |
| 0x000020 | Becker |
| 0x000021 | Preh |
| 0x000022 | Alps |
| 0x000023 | Motorola |
| 0x000024 | Temic |
| 0x000025 | Webasto |
| 0x000026 | MotoMeter |
| 0x000027 | Delphi PHI |
| 0x000028 | DODUCO => BERU |
| 0x000029 | DENSO |
| 0x000030 | NEC |
| 0x000031 | DASA |
| 0x000032 | Pioneer |
| 0x000033 | Jatco |
| 0x000034 | Fuba |
| 0x000035 | UK-NSI |
| 0x000036 | AABG |
| 0x000037 | Dunlop |
| 0x000038 | Sachs |
| 0x000039 | ITT |
| 0x000040 | FTE |
| 0x000041 | Megamos |
| 0x000042 | TRW |
| 0x000043 | Wabco |
| 0x000044 | ISAD Electronic Systems |
| 0x000045 | HEC (Hella Electronics Corporation) |
| 0x000046 | Gemel |
| 0x000047 | ZF |
| 0x000048 | GMPT |
| 0x000049 | Harman Kardon |
| 0x000050 | Remes |
| 0x000051 | ZF Lenksysteme |
| 0x000052 | Magneti Marelli |
| 0x000053 | Borg Instruments |
| 0x000054 | GETRAG |
| 0x000055 | BHTC (Behr Hella Thermocontrol) |
| 0x000056 | Siemens VDO Automotive |
| 0x000057 | Visteon |
| 0x000058 | Autoliv |
| 0x000059 | Haberl |
| 0x000060 | Magna Steyr |
| 0x000061 | Marquardt |
| 0x000062 | AB-Elektronik |
| 0x000063 | Siemens VDO Borg |
| 0x000064 | Hirschmann Electronics |
| 0x000065 | Hoerbiger Electronics |
| 0x000066 | Thyssen Krupp Automotive Mechatronics |
| 0x000067 | Gentex GmbH |
| 0x000068 | Atena GmbH |
| 0x000069 | Magna-Donelly |
| 0x000070 | Koyo Steering Europe |
| 0x000071 | NSI B.V |
| 0x000072 | AISIN AW CO.LTD |
| 0x000073 | Shorlock |
| 0x000074 | Schrader |
| 0x000075 | BERU Electronics GmbH |
| 0x000076 | CEL |
| 0x000077 | Audio Mobil |
| 0x000078 | rd electronic |
| 0x000079 | iSYS RTS GmbH |
| 0x000080 | Westfalia Automotive GmbH |
| 0x000081 | Tyco Electronics |
| 0x000082 | Paragon AG |
| 0x000083 | IEE S.A |
| 0x000084 | TEMIC AUTOMOTIVE of NA |
| 0x000085 | AKsys GmbH |
| 0x000086 | META System |
| 0x000087 | Hülsbeck & Fürst GmbH & Co KG |
| 0x000088 | Mann & Hummel Automotive GmbH |
| 0x000089 | Brose Fahrzeugteile GmbH & Co |
| 0x000090 | Keihin |
| 0x000091 | Vimercati S.p.A. |
| 0x000092 | CRH |
| 0x000093 | TPO Display Corp. |
| 0x000094 | KÜSTER Automotive Control |
| 0x000095 | Hitachi Automotive |
| 0x000096 | Continental Automotive |
| 0x000097 | TI-Automotive |
| 0x000098 | Hydro |
| 0x000099 | Johnson Controls |
| 0x00009A | Takata- Petri |
| 0x00009B | Mitsubishi Electric B.V. (Melco) |
| 0x00009C | Autokabel |
| 0x00009D | GKN-Driveline |
| 0x00009E | Zollner Elektronik AG |
| 0x00009F | PEIKER acustics GmbH |
| 0x0000A0 | Bosal-Oris |
| 0x0000A1 | Cobasys |
| 0x0000A2 | Lighting Reutlingen GmbH |
| 0x0000A3 | CONTI VDO |
| 0x0000A4 | ADC Automotive Distance Control Systems GmbH |
| 0x0000A5 | Funkwerk Dabendorf GmbH |
| 0x0000A6 | Lame |
| 0x0000A7 | Magna/Closures |
| 0x0000A8 | Wanyu |
| 0x0000A9 | Thyssen Krupp Presta |
| 0x0000AA | ArvinMeritor |
| 0x0000AB | Kongsberg Automotive GmbH |
| 0x0000AC | SMR Automotive Mirrors |
| 0x0000AD | So.Ge.Mi. |
| 0x0000AE | MTA |
| 0x0000AF | Alfmeier |
| 0x0000B0 | ELTEK VALERE DEUTSCHLAND GMBH |
| 0x0000B1 | Omron Automotive Electronics Europe Group |
| 0x0000B2 | ASK |
| 0x0000B3 | CML Innovative Technologies GmbH & Co. KG |
| 0x0000B4 | APAG Elektronik AG |
| 0xFFFFFF | unbekannter Hersteller |
FARTTEXTE
Dimensions: 19 rows × 2 columns
| ARTNR | ARTTEXT |
|---|---|
| 0x00 | keine Fehlerart verfügbar |
| 0x04 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x05 | Fehler momentan vorhanden und bereits gespeichert |
| 0x08 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x09 | Fehler momentan vorhanden und bereits gespeichert |
| 0x0C | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x0D | Fehler momentan vorhanden und bereits gespeichert |
| 0x40 | unbekannte Fehlerart |
| 0x44 | Fehler gespeichert |
| 0x45 | Fehler gespeichert |
| 0x48 | Fehler gespeichert |
| 0x49 | Fehler gespeichert |
| 0x4C | Fehler gespeichert |
| 0x4D | Fehler gespeichert |
| 0x10 | Testbedingungen erfüllt |
| 0x11 | Testbedingungen noch nicht erfüllt |
| 0x80 | Fehler würde kein Aufleuchten einer Warnlampe verursachen |
| 0x81 | Fehler würde das Aufleuchten einer Warnlampe verursachen |
| 0xFF | unbekannte Fehlerart |
DIGITALARGUMENT
Dimensions: 17 rows × 2 columns
| TEXT | WERT |
|---|---|
| ein | 1 |
| aus | 0 |
| ja | 1 |
| nein | 0 |
| auf | 1 |
| ab | 0 |
| an | 1 |
| yes | 1 |
| no | 0 |
| on | 1 |
| off | 0 |
| up | 1 |
| down | 0 |
| true | 1 |
| false | 0 |
| 1 | 1 |
| 0 | 0 |
PROZESSKLASSEN
Dimensions: 25 rows × 3 columns
| WERT | PROZESSKLASSE | BEZEICHNUNG |
|---|---|---|
| 0x00 | - | ungueltig |
| 0x01 | HWEL | Hardware (Elektronik) |
| 0x02 | HWAP | Hardwareauspraegung |
| 0x03 | HWFR | Hardwarefarbe |
| 0x05 | CAFD | Codierdaten |
| 0x06 | BTLD | Bootloader |
| 0x08 | SWFL | Software ECU Speicherimage |
| 0x09 | SWFF | Flash File Software |
| 0x0A | SWPF | Pruefsoftware |
| 0x0B | ONPS | Onboard Programmiersystem |
| 0x0F | FAFP | FA2FP |
| 0x1A | TLRT | Temporaere Loeschroutine |
| 0x1B | TPRG | Temporaere Programmierroutine |
| 0x07 | FLSL | Flashloader Slave |
| 0x0C | IBAD | Interaktive Betriebsanleitung Daten |
| 0x10 | FCFA | Freischaltcode Fahrzeug-Auftrag |
| 0x1C | BLUP | Bootloader-Update Applikation |
| 0x1D | FLUP | Flashloader-Update Applikation |
| 0x04 | GWTB | Gateway-Tabelle |
| 0xA0 | ENTD | Entertainment Daten |
| 0xA1 | NAVD | Navigation Daten |
| 0xA2 | FCFN | Freischaltcode Funktion |
| 0xC0 | SWUP | Software-Update Package |
| 0xC1 | SWIP | Index Software-Update Package |
| 0xFF | - | ungueltig |
SVK_ID
Dimensions: 65 rows × 2 columns
| WERT | BEZEICHNUNG |
|---|---|
| 0x01 | SVK_AKTUELL |
| 0x02 | SVK_SUPPLIER |
| 0x03 | SVK_WERK |
| 0x04 | SVK_BACKUP_01 |
| 0x05 | SVK_BACKUP_02 |
| 0x06 | SVK_BACKUP_03 |
| 0x07 | SVK_BACKUP_04 |
| 0x08 | SVK_BACKUP_05 |
| 0x09 | SVK_BACKUP_06 |
| 0x0A | SVK_BACKUP_07 |
| 0x0B | SVK_BACKUP_08 |
| 0x0C | SVK_BACKUP_09 |
| 0x0D | SVK_BACKUP_10 |
| 0x0E | SVK_BACKUP_11 |
| 0x0F | SVK_BACKUP_12 |
| 0x10 | SVK_BACKUP_13 |
| 0x11 | SVK_BACKUP_14 |
| 0x12 | SVK_BACKUP_15 |
| 0x13 | SVK_BACKUP_16 |
| 0x14 | SVK_BACKUP_17 |
| 0x15 | SVK_BACKUP_18 |
| 0x16 | SVK_BACKUP_19 |
| 0x17 | SVK_BACKUP_20 |
| 0x18 | SVK_BACKUP_21 |
| 0x19 | SVK_BACKUP_22 |
| 0x1A | SVK_BACKUP_23 |
| 0x1B | SVK_BACKUP_24 |
| 0x1C | SVK_BACKUP_25 |
| 0x1D | SVK_BACKUP_26 |
| 0x1E | SVK_BACKUP_27 |
| 0x1F | SVK_BACKUP_28 |
| 0x20 | SVK_BACKUP_29 |
| 0x21 | SVK_BACKUP_30 |
| 0x22 | SVK_BACKUP_31 |
| 0x23 | SVK_BACKUP_32 |
| 0x24 | SVK_BACKUP_33 |
| 0x25 | SVK_BACKUP_34 |
| 0x26 | SVK_BACKUP_35 |
| 0x27 | SVK_BACKUP_36 |
| 0x28 | SVK_BACKUP_37 |
| 0x29 | SVK_BACKUP_38 |
| 0x2A | SVK_BACKUP_39 |
| 0x2B | SVK_BACKUP_40 |
| 0x2C | SVK_BACKUP_41 |
| 0x2D | SVK_BACKUP_42 |
| 0x2E | SVK_BACKUP_43 |
| 0x2F | SVK_BACKUP_44 |
| 0x30 | SVK_BACKUP_45 |
| 0x31 | SVK_BACKUP_46 |
| 0x32 | SVK_BACKUP_47 |
| 0x33 | SVK_BACKUP_48 |
| 0x34 | SVK_BACKUP_49 |
| 0x35 | SVK_BACKUP_50 |
| 0x36 | SVK_BACKUP_51 |
| 0x37 | SVK_BACKUP_52 |
| 0x38 | SVK_BACKUP_53 |
| 0x39 | SVK_BACKUP_54 |
| 0x3A | SVK_BACKUP_55 |
| 0x3B | SVK_BACKUP_56 |
| 0x3C | SVK_BACKUP_57 |
| 0x3D | SVK_BACKUP_58 |
| 0x3E | SVK_BACKUP_59 |
| 0x3F | SVK_BACKUP_60 |
| 0x40 | SVK_BACKUP_61 |
| 0xXY | ERROR_UNKNOWN |
DTCEXTENDEDDATARECORDNUMBER
Dimensions: 5 rows × 3 columns
| WERT | TEXT | ANZ_BYTE |
|---|---|---|
| 0x00 | ISO_RESERVED | 0 |
| 0x01 | CONDITION_BYTE | 1 |
| 0x02 | HFK | 1 |
| 0x03 | HLZ | 1 |
| 0xFF | RECORD_UNKNOWN | 0 |
DTCSNAPSHOTIDENTIFIER
Dimensions: 5 rows × 9 columns
| UWNR | UWTEXT | UW_EINH | L/H | UWTYP | NAME | MUL | DIV | ADD |
|---|---|---|---|---|---|---|---|---|
| 0x1700 | KM_STAND | 0-n | - | 0xFFFFFF | - | 1 | 1 | 0.000000 |
| 0x1701 | ABS_ZEIT | 0-n | - | 0xFFFFFFFF | - | 1 | 1 | 0.000000 |
| 0x1702 | SAE_CODE | 0-n | - | 0xFFFFFF | - | 1 | 1 | 0.000000 |
| 0x1731 | Fehlerklasse_DTC | - | - | u char | - | 1 | 1 | 0.000000 |
| 0xFFFF | IDENTIFIER_UNKNOWN | - | - | 0xFFFFFF | - | 1 | 1 | 0.000000 |
FEHLERKLASSE
Dimensions: 5 rows × 2 columns
| NR | TEXT |
|---|---|
| 0x00 | Keine Fehlerklasse verfuegbar |
| 0x01 | Ueberpruefung bei naechstem Werkstattbesuch |
| 0x02 | Ueberpruefung bei naechstem Halt |
| 0x04 | Ueberpruefung sofort erforderlich ! |
| 0xFF | unbekannte Fehlerklasse |
DIAGMODE
Dimensions: 11 rows × 3 columns
| NR | MODE | MODE_TEXT |
|---|---|---|
| 0x00 | UNGUELTIG | DefaultMode |
| 0x01 | DEFAULT | DefaultMode |
| 0x02 | ECUPM | ECUProgrammingMode |
| 0x03 | ECUEXTDIAG | ECUExtendedDiagnosticSession |
| 0x04 | ECUSSDS | ECUSafetySystemDiagnosticSession |
| 0x40 | ECUEOL | ECUEndOfLineSession |
| 0x41 | ECUCODE | ECUCodingSession |
| 0x42 | ECUSWT | ECUSwtSession |
| 0x43 | ECUHDD | ECUHDDDownloadSession |
| 0x4F | ECUDEVELOP | ECUDevelopmentSession |
| 0xXY | -- | unbekannter Diagnose-Mode |
VERBAUORTTABELLE
Dimensions: 176 rows × 3 columns
| ORT | ORTTEXT | LIN_2_FORMAT |
|---|---|---|
| 0x0100 | Batteriesensor BSD | - |
| 0x0150 | Ölqualitätsensor BSD | - |
| 0x0200 | Elektrische Wasserpumpe BSD | - |
| 0x0250 | Elektrische Kraftstoffpumpe BSD | - |
| 0x0300 | Generator 1 | - |
| 0x0350 | Generator 2 | - |
| 0x03A0 | Druck- Temperatursensor Tank | 1 |
| 0x03C0 | EAC-Sensor | - |
| 0x0400 | Schaltzentrum Lenksäule | - |
| 0x0500 | DSC Sensor-Cluster | - |
| 0x0600 | Nahbereichsradarsensor links | - |
| 0x0700 | Nahbereichsradarsensor rechts | - |
| 0x0800 | Funkempfänger | - |
| 0x0900 | Elektrische Lenksäulenverriegelung | - |
| 0x0A00 | Regen- Lichtsensor | - |
| 0x290A00 | DSC Hydraulikblock | - |
| 0x0B00 | Nightvision Kamera | - |
| 0x0C00 | TLC Kamera | - |
| 0x0D00 | Spurwechselradarsensor hinten links | - |
| 0x0E00 | Heckklima Bedienteil rechts | 1 |
| 0x0F00 | Rearview Kamera hinten | 1 |
| 0x1000 | Topview Kamera Außenspiegel links | 1 |
| 0x1100 | Topview Kamera Außenspiegel rechts | 1 |
| 0x1200 | Sideview Kamera Stoßfänger vorne links | 1 |
| 0x1300 | Sideview Kamera Stoßfänger vorne rechts | 1 |
| 0x1400 | Wischermotor | 1 |
| 0x1500 | Regen- Lichtsensor | 1 |
| 0x1600 | Innenspiegel | 1 |
| 0x1700 | Garagentoröffner | 1 |
| 0x1800 | AUC-Sensor | 1 |
| 0x1900 | Druck- Temperatursensor | 1 |
| 0x1A20 | Schalterblock Sitzheizung hinten links | 1 |
| 0x1A40 | Schalterblock Sitzheizung hinten rechts | 1 |
| 0x1A60 | Sitzheizung Fahrer | 1 |
| 0x1A80 | Sitzheizung Beifahrer | 1 |
| 0x1AA0 | Sitzheizung Fahrer hinten | 1 |
| 0x1AC0 | Sitzheizung Beifahrer hinten | 1 |
| 0x1B00 | Schalterblock Sitzmemory/-massage Fahrer | 1 |
| 0x1C00 | Schalterblock Sitzmemory/-massage Beifahrer | 1 |
| 0x1C80 | Sitzverstellschalter Beifahrer über Fond | 1 |
| 0x1D00 | Sonnenrollo Seitenfenster Fahrer | 1 |
| 0x1E00 | Sonnenrollo Seitenfenster Beifahrer | 1 |
| 0x1E40 | Heckklappenemblem | 1 |
| 0x1F00 | KAFAS Kamera | 1 |
| 0x2000 | Automatische Anhängevorrichtung | 1 |
| 0x2100 | SINE | 1 |
| 0x2110 | DWA Mikrowellensensor vorne rechts | 1 |
| 0x2120 | DWA Mikrowellensensor hinten rechts | 1 |
| 0x2130 | DWA Mikrowellensensor hinten links | 1 |
| 0x2140 | DWA Mikrowellensensor vorne links | 1 |
| 0x2150 | DWA Mikrowellensensor hinten | 1 |
| 0x2180 | DWA Ultraschallsensor | 1 |
| 0x2200 | Aussenspiegel Fahrer | - |
| 0x2300 | Aussenspiegel Beifahrer | - |
| 0x2400 | Schaltzentrum Tür | 1 |
| 0x2500 | Schalterblock Sitz Fahrer | 1 |
| 0x2600 | Schalterblock Sitz Beifahrer | 1 |
| 0x2700 | Gurtbringer Fahrer | 1 |
| 0x2800 | Gurtbringer Beifahrer | 1 |
| 0x2900 | Treibermodul Scheinwerfer links | 1 |
| 0x2A00 | Treibermodul Scheinwerfer rechts | 1 |
| 0x2B00 | Bedieneinheit Fahrerassistenzsysteme | 1 |
| 0x2C00 | Bedieneinheit Licht | 1 |
| 0x2D00 | Smart Opener | 1 |
| 0x2E00 | LED-Hauptlicht-Modul links | 1 |
| 0x2F00 | LED-Hauptlicht-Modul rechts | 1 |
| 0x0910 | Elektrische Lenksäulenverriegelung | 1 |
| 0x3200 | Funkempfänger | 1 |
| 0x3300 | Funkempfänger 2 | 1 |
| 0x3400 | Türgriffelektronik Fahrer | - |
| 0x3500 | Türgriffelektronik Beifahrer | - |
| 0x3600 | Türgriffelektronik Fahrer hinten | - |
| 0x3700 | Türgriffelektronik Beifahrer hinten | - |
| 0x3800 | Telestart-Handsender 1 | - |
| 0x3900 | Telestart-Handsender 2 | - |
| 0x3A00 | Fond-Fernbedienung | - |
| 0x3B00 | Elektrische Wasserpumpe | 1 |
| 0x3B10 | Elektrische Wasserpumpe 1 | 1 |
| 0x3B20 | Elektrische Wasserpumpe 2 | 1 |
| 0x3B80 | Elektrische Zusatzwasserpumpe | 1 |
| 0x3C00 | Batteriesensor LIN | - |
| 0x3D00 | Aktives Kühlklappensystem | 1 |
| 0x3E00 | PCU(DCDC) | 1 |
| 0x3E80 | DCDC Versorgung Zustartbatterie | 1 |
| 0x3F00 | Startergenerator | 1 |
| 0x3F80 | Generator | 1 |
| 0x4000 | Sitzverstellschalter Fahrer | 1 |
| 0x4100 | Sitzverstellschalter Beifahrer | 1 |
| 0x4200 | Sitzverstellschalter Fahrer hinten | 1 |
| 0x4300 | Sitzverstellschalter Beifahrer hinten | 1 |
| 0x4400 | Gepäckraumschalter links | 1 |
| 0x4500 | Gepäckraumschalter rechts | 1 |
| 0x4600 | Nackenwärmer | 1 |
| 0x4700 | Nackenwärmer Bedienschalter | 1 |
| 0x4A00 | Fond-Klimaanlage | 1 |
| 0x4B00 | Elektrischer Klimakompressor | 1 |
| 0x4C00 | Klimabedienteil | 1 |
| 0x4D00 | Gebläseregler | 1 |
| 0x4E00 | Klappenmotor | 0 |
| 0x4F00 | Elektrischer Kältemittelverdichter eKMV | 1 |
| 0x4F80 | Elektrischer Zuheizer PTC | 1 |
| 0x6000 | Standheizung | 1 |
| 0x6100 | Wärmepumpe | 1 |
| 0x6200 | elektrischer Durchlaufheizer | 1 |
| 0x6300 | Ionisator | 1 |
| 0x6400 | Bedufter | 1 |
| 0x5000 | PMA Sensor links | 1 |
| 0x5100 | PMA Sensor rechts | 1 |
| 0x5200 | CID-Klappe | - |
| 0x5300 | Schaltzentrum Lenksäule | 1 |
| 0x5400 | Multifunktionslenkrad | 1 |
| 0x5500 | Lenkradelektronik | 1 |
| 0x5600 | CID | - |
| 0x5700 | Satellit Upfront links | 0 |
| 0x5708 | Satellit Upfront rechts | 0 |
| 0x5710 | Satellit Tür links | 0 |
| 0x5718 | Satellit Tür rechts | 0 |
| 0x5720 | Satellit B-Säule links X | 0 |
| 0x5728 | Satellit B-Säule rechts X | 0 |
| 0x5730 | Satellit B-Säule links Y | 0 |
| 0x5738 | Satellit B-Säule rechts Y | 0 |
| 0x5740 | Satellit Zentralsensor X | 0 |
| 0x5748 | Satellit Zentralsensor Y | 0 |
| 0x5750 | Satellit Zentralsensor Low g Y | 0 |
| 0x5758 | Satellit Zentralsensor Low g Z | 0 |
| 0x5760 | Satellit Zentralsensor Roll Achse | 0 |
| 0x5768 | Fussgängerschutz Sensor links | 0 |
| 0x5770 | Fussgängerschutz Sensor rechts | 0 |
| 0x5778 | Fussgängerschutz Sensor mitte | 0 |
| 0x5780 | Fussgängerschutzsensor statisch | 0 |
| 0x5788 | Satellit C-Säule links Y | 0 |
| 0x5790 | Satellit C-Säule rechts Y | 0 |
| 0x5798 | Satellit Zentrale Körperschall | 0 |
| 0x57A0 | Kapazitive Insassen- Sensorik CIS | 1 |
| 0x57A8 | Sitzbelegungserkennung Beifahrer SBR | 1 |
| 0x57B0 | Fussgängerschutzsensor dynamisch 1 | 0 |
| 0x57B8 | Fussgängerschutzsensor dynamisch 2 | 0 |
| 0x5800 | HUD | 1 |
| 0x5900 | Audio-Bedienteil | 1 |
| 0x5A00 | Innenlichtelektronik | 1 |
| 0x5B00 | Zentralinstrument | - |
| 0x5C00 | Elektrische Lenksäulenverstellung ELSV | 1 |
| 0x5D00 | Hands-Off Detection HOD | 1 |
| 0x5E01 | Innenbeleuchtung Fußraum Fahrer vorne | 1 |
| 0x5E02 | Innenbeleuchtung Fußraum Fahrer hinten | 1 |
| 0x5E03 | Innenbeleuchtung Fußraum Beifahrer vorne | 1 |
| 0x5E04 | Innenbeleuchtung Fußraum Beifahrer hinten | 1 |
| 0x5E05 | Innenbeleuchtung Fahrertür vorne oben | 1 |
| 0x5E06 | Innenbeleuchtung Fahrertür vorne Mitte | 1 |
| 0x5E07 | Innenbeleuchtung Fahrertür vorne unten | 1 |
| 0x5E08 | Innenbeleuchtung Fahrertür vorne Kartentasche | 1 |
| 0x5E09 | Innenbeleuchtung Fahrertür hinten oben | 1 |
| 0x5E0A | Innenbeleuchtung Fahrertür hinten unten | 1 |
| 0x5E0B | Innenbeleuchtung Fahrertür hinten Kartentasche | 1 |
| 0x5E0C | Innenbeleuchtung Beifahrertür vorne oben | 1 |
| 0x5E0D | Innenbeleuchtung Beifahrertür vorne Mitte | 1 |
| 0x5E0E | Innenbeleuchtung Beifahrertür vorne unten | 1 |
| 0x5E0F | Innenbeleuchtung Beifahrertür vorne Kartentasche | 1 |
| 0x5E10 | Innenbeleuchtung Beifahrertür hinten oben | 1 |
| 0x5E11 | Innenbeleuchtung Beifahrertür hinten unten | 1 |
| 0x5E12 | Innenbeleuchtung Beifahrertür hinten Kartentasche | 1 |
| 0x5E13 | Innenbeleuchtung I-Tafel Fahrer oben | 1 |
| 0x5E14 | Innenbeleuchtung I-Tafel Fahrer unten | 1 |
| 0x5E15 | Innenbeleuchtung I-Tafel oben Mitte | 1 |
| 0x5E16 | Innenbeleuchtung I-Tafel unten Mitte | 1 |
| 0x5E17 | Innenbeleuchtung I-Tafel oben Beifahrer | 1 |
| 0x5E18 | Innenbeleuchtung I-Tafel unten Beifahrer | 1 |
| 0x5E19 | Innenbeleuchtung B-Säule Fahrer | 1 |
| 0x5E1A | Innenbeleuchtung B-Säule Beifahrer | 1 |
| 0x5E1B | Innenbeleuchtung Lehne Fahrersitz | 1 |
| 0x5E1C | Innenbeleuchtung Lehne Beifahrersitz | 1 |
| 0x5E1D | Innenbeleuchtung Centerstack | 1 |
| 0x5E1E | Innenbeleuchtung Mittelkonsole Ablagefach | 1 |
| 0x5E1F | Innenbeleuchtung Gangwahlschalter links | 1 |
| 0x5E20 | Innenbeleuchtung Gangwahlschalter rechts | 1 |
| 0xFFFF | unbekannter Verbauort | - |
PARTNRTABELLE
Dimensions: 1 rows × 3 columns
| PART_NR | BMW_NR | KOMMENTAR |
|---|---|---|
| -- | -- | unbekannte Teilenummer |
LIEFERANTENLIN
Dimensions: 99 rows × 2 columns
| LIEF_NR | LIEF_TEXT |
|---|---|
| 0x0001 | Audi |
| 0x0002 | BMW |
| 0x0003 | DaimlerChrysler |
| 0x0004 | Motorola |
| 0x0005 | VCT/Mentor Graphics |
| 0x0006 | VW (VW-Group) |
| 0x0007 | Volvo Cars (Ford Group) |
| 0x000B | Freescale Semiconductor |
| 0x0011 | NXP Semiconductors |
| 0x0012 | ST Microelectronics |
| 0x0013 | Melexis |
| 0x0014 | Microchip |
| 0x0015 | CRF |
| 0x0016 | Renesas Technology Europe GmbH |
| 0x0017 | Atmel |
| 0x0018 | Magnet Marelli |
| 0x0019 | NEC |
| 0x001A | Fujitsu |
| 0x001B | Opel |
| 0x001C | Infineon |
| 0x001D | AMI Semiconductor |
| 0x001E | Vector Informatik |
| 0x001F | Brose |
| 0x0020 | ZMD |
| 0x0021 | ihr |
| 0x0022 | Visteon |
| 0x0023 | ELMOS |
| 0x0024 | ON Semi |
| 0x0025 | Denso |
| 0x0026 | c&s |
| 0x0027 | Renault |
| 0x0028 | Renesas Technology Europe Limited |
| 0x0029 | Yazaki |
| 0x002A | Trinamic Microchips |
| 0x002B | Allegro Microsystems |
| 0x002C | Toyota |
| 0x002D | PSA Peugeot Citroën |
| 0x002E | Westsächsische Hochschule Zwickau |
| 0x002F | Micron AG |
| 0x0030 | Delphi Deutschland GmbH |
| 0x0031 | Texas Instruments Deutschland GmbH |
| 0x0032 | Maxim Integrated Products |
| 0x0033 | Bertrandt Ingenierbüro GmbH |
| 0x0034 | PKC Group Oyi |
| 0x0035 | BayTech IKs |
| 0x0036 | Hella KGaA Hueck & Co. |
| 0x0037 | Continental Temic microelectronic GmbH |
| 0x0038 | Johnson Controls GmbH |
| 0x0039 | Toshiba Electronics Europe GmbH |
| 0x003A | Analog Devices |
| 0x003B | TRW Automotive Electronics & Components GmbH & Co. KG |
| 0x003C | Advanced Data Controls, Corp. |
| 0x003D | GÖPEL electronic GmbH |
| 0x003E | Dr. Ing. h.c. F. Porsche AG |
| 0x003F | Marquardt GmbH |
| 0x0040 | ETAS GmbH |
| 0x0041 | Micronas GmbH |
| 0x0042 | Preh GmbH |
| 0x0043 | GENTEX CORPORATION |
| 0x0044 | ZF Lenksysteme GmbH |
| 0x0045 | Nagares S.A. |
| 0x0046 | MAN Nutzfahrzeuge AG |
| 0x0047 | BITRON SpA BU Grugliasco |
| 0x0048 | Pierburg GmbH |
| 0x0049 | Alps Electric Co., Ltd |
| 0x004A | Beru Electronics GmbH |
| 0x004B | Paragon AG |
| 0x004C | Silicon Laboratories |
| 0x004D | Sensata Technologies Holland B.V. |
| 0x004E | Meta System S.p.A |
| 0x004F | Dräxlmaier Systemtechnik GmbH |
| 0x0050 | Grupo Antolin Ingenieria, S.A. |
| 0x0051 | MAGNA-Donnelly GmbH&Co.KG |
| 0x0052 | IEE S.A. |
| 0x0053 | austriamicrosystems AG |
| 0x0054 | Agilent Technologies |
| 0x0055 | Lear Corporation |
| 0x0056 | KOSTAL Ireland GmbH |
| 0x0057 | LIPOWSKY Industrie-Elektronik GmbH |
| 0x0058 | Sanken Electric Co.,Ltd |
| 0x0059 | Elektrobit Automotive GmbH |
| 0x005A | VIMERCATI S.p.A. |
| 0x005B | AB Volvo |
| 0x005C | SMSC Europe GmbH |
| 0x0060 | Sitronic |
| 0x0061 | Flextronics / Sidler Automotive |
| 0x0062 | EAO Automotive |
| 0x0063 | helag-electronic |
| 0x0064 | Magna International |
| 0x0065 | ARVINMERITOR |
| 0x0066 | Valeo SA |
| 0x0067 | Defond Holding / BJAutomotive |
| 0x0068 | Industrie Saleri S. p. A. |
| 0x0069 | ROHM Semiconductor GmbH |
| 0x0070 | Alfmeier AG |
| 0x0071 | Sanden Corporation |
| 0x0072 | Huf Hülsbeck & Fürst GmbH&Co KG |
| 0x0073 | ebm-papst St. Georgen GmbH&Co. KG |
| 0xFFFF | unbekannter Hersteller |
IARTTEXTE
Dimensions: 18 rows × 2 columns
| ARTNR | ARTTEXT |
|---|---|
| 0x00 | keine Fehlerart verfügbar |
| 0x04 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x05 | Fehler momentan vorhanden und bereits gespeichert |
| 0x08 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x09 | Fehler momentan vorhanden und bereits gespeichert |
| 0x0C | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x0D | Fehler momentan vorhanden und bereits gespeichert |
| 0x44 | Fehler gespeichert |
| 0x45 | Fehler gespeichert |
| 0x48 | Fehler gespeichert |
| 0x49 | Fehler gespeichert |
| 0x4C | Fehler gespeichert |
| 0x4D | Fehler gespeichert |
| 0x10 | Testbedingungen erfüllt |
| 0x11 | Testbedingungen noch nicht erfüllt |
| 0x80 | Fehler würde kein Aufleuchten einer Warnlampe verursachen |
| 0x81 | Fehler würde das Aufleuchten einer Warnlampe verursachen |
| 0xFF | unbekannte Fehlerart |
UDS_TAB_ROE_AKTIV
Dimensions: 3 rows × 2 columns
| NR | TEXT |
|---|---|
| 0x00 | Aktive Fehlermeldung deaktiviert |
| 0x01 | Aktive Fehlermeldung aktiviert |
| 0xFF | Status der aktiven Fehlermeldung nicht feststellbar |
JOBRESULTEXTENDED
Dimensions: 1 rows × 2 columns
| SB | STATUS_TEXT |
|---|---|
| 0xXY | ERROR_UNKNOWN |
BETRIEBSMODE
Dimensions: 6 rows × 3 columns
| WERT | TEXT | BEDEUTUNG |
|---|---|---|
| 0x00 | Allgemeiner Fertigungs- und Energiesparmode | Hier deaktivierte Funktionen gemäß FeTra-Liste festhalten |
| 0x01 | Spezieller Energiesparmode | - |
| 0x02 | ECOS-Mode | - |
| 0x03 | MOST-Mode | - |
| 0x04 | Rollenmode | - |
| 0xFF | ungültiger Betriebsmode | ungültig |
FORTTEXTE
Dimensions: 23 rows × 3 columns
| ORT | ORTTEXT | EREIGNIS_DTC |
|---|---|---|
| 0x805801 | LED Versorgung: Kurzschluss | 0 |
| 0x024709 | Codierung: Fehler bei Codierdatentransaktion aufgetreten | 0 |
| 0x024700 | Energiesparmode aktiv | 0 |
| 0x02470C | Codierung: Unplausible Daten während Codierdatentransaktion | 0 |
| 0x80580B | Abschaltung wegen Übertemperatur | 1 |
| 0xDAC514 | B2-CAN Control Module Bus OFF | 0 |
| 0x805810 | Überspannung | 1 |
| 0x805806 | Schrittmotor defekt | 0 |
| 0x805815 | Botschaft 0x22C (CTR_GZA) - Timeout | 1 |
| 0x805800 | Spotlight: Kurzschluss Kathode | 0 |
| 0x02FF47 | Dummy-Fehlerspeichereintrag im Komponentenfehlerbereich nur für Testzwecke | 1 |
| 0x805817 | Steuersignal Gezieltes Anleuchten ungültig | 0 |
| 0x805802 | Spotlight: Leitungsunterbrechung | 0 |
| 0x805805 | Designleuchte: Leitungsunterbrechung | 0 |
| 0x805807 | Schrittmotortreiber defekt | 0 |
| 0x80580F | Unterspannung | 1 |
| 0xDACBFF | Dummy-Fehlerspeichereintrag im Netzwerkfehlerbereich nur für Testzwecke | 1 |
| 0x02470A | Codierung: Signatur der Codierdaten ungültig | 0 |
| 0x02470B | Codierung: Codierdaten passen nicht zum Fahrzeug | 0 |
| 0x805816 | Signal CTR_GZADL ungültig | 1 |
| 0x805803 | Designleuchte: Kurzschluss Kathode | 0 |
| 0x024708 | Codierung: Steuergerät ist nicht codiert | 0 |
| 0xFFFFFF | unbekannter Fehlerort | 0 |
FDETAILSTRUKTUR
Dimensions: 6 rows × 2 columns
| NAME | TYP |
|---|---|
| F_UWB_ERW | ja |
| SAE_CODE | nein |
| F_HLZ | ja |
| F_SEVERITY | nein |
| F_UWB_SATZ | 2 |
| F_HLZ_VIEW | nein |
DTCBEREICHE
Dimensions: 20 rows × 4 columns
| DTC-TYP | MINIMALWERT | MAXIMALWERT | BESCHREIBUNG |
|---|---|---|---|
| AllgemeinerDTC | 020000 | 02FFFF | Die zulässigen Bereiche sind für jedes Steuergerät festgelegt. Es können mehrere gültige Bereiche (Kacheln) definiert werden. |
| SystembusDTC | 930030 | 930055 | Zulässiger Bereich wird mittels Formel berechnet. Enthält physikalische Fehler bzw. Protokollfehler des Systembusses. |
| SystembusDTC | DAC487 | DAC48F | Zulässiger Bereich wird mittels Formel berechnet. Enthält physikalische Fehler bzw. Protokollfehler des Systembusses. |
| SystembusDTC | DAC401 | DAC40A | Zulässiger Bereich wird mittels Formel berechnet. Enthält physikalische Fehler bzw. Protokollfehler des Systembusses. |
| SystembusDTC | DAC469 | DAC472 | Zulässiger Bereich wird mittels Formel berechnet. Enthält physikalische Fehler bzw. Protokollfehler des Systembusses. |
| SystembusDTC | DAC47D | DAC486 | Zulässiger Bereich wird mittels Formel berechnet. Enthält physikalische Fehler bzw. Protokollfehler des Systembusses. |
| SystembusDTC | DAC415 | DAC41E | Zulässiger Bereich wird mittels Formel berechnet. Enthält physikalische Fehler bzw. Protokollfehler des Systembusses. |
| SystembusDTC | DAC473 | DAC47C | Zulässiger Bereich wird mittels Formel berechnet. Enthält physikalische Fehler bzw. Protokollfehler des Systembusses. |
| SystembusDTC | DAC41F | DAC43E | Zulässiger Bereich wird mittels Formel berechnet. Enthält physikalische Fehler bzw. Protokollfehler des Systembusses. |
| SystembusDTC | DAC501 | DAC50A | Zulässiger Bereich wird mittels Formel berechnet. Enthält physikalische Fehler bzw. Protokollfehler des Systembusses. |
| SystembusDTC | DAC50B | DAC514 | Zulässiger Bereich wird mittels Formel berechnet. Enthält physikalische Fehler bzw. Protokollfehler des Systembusses. |
| SystembusDTC | DAC43F | DAC449 | Zulässiger Bereich wird mittels Formel berechnet. Enthält physikalische Fehler bzw. Protokollfehler des Systembusses. |
| SystembusDTC | 930000 | 930011 | Zulässiger Bereich wird mittels Formel berechnet. Enthält physikalische Fehler bzw. Protokollfehler des Systembusses. |
| SystembusDTC | DAC45F | DAC468 | Zulässiger Bereich wird mittels Formel berechnet. Enthält physikalische Fehler bzw. Protokollfehler des Systembusses. |
| SystembusDTC | DAC40B | DAC414 | Zulässiger Bereich wird mittels Formel berechnet. Enthält physikalische Fehler bzw. Protokollfehler des Systembusses. |
| SubbusDTC | DACC00 | DAD3FF | Zulässiger Bereich wird mittels Formel berechnet. Enthält physikalische Fehler bzw. Protokollfehler des Systembusses. |
| SignalDTC | DAD400 | DB03FF | Ist aus einem vorgegebenen Offset-Bereich frei wählbar. Enthält Signalfehler, die SG-spezifisch sind. |
| SignalDTC | DAD400 | DB03FF | Ist aus einem vorgegebenen Offset-Bereich frei wählbar. Enthält Signalfehler, die SG-spezifisch sind. |
| SignalDTC | DACBFF | DACBFF | Ist aus einem vorgegebenen Offset-Bereich frei wählbar. Enthält Signalfehler, die SG-spezifisch sind. |
| KomponentenDTC | 805800 | 80587F | Die zulässigen Bereiche sind für jedes Steuergerät festgelegt. Es können mehrere gültige Bereiche (Kacheln) definiert werden. |
FUMWELTTEXTE
Dimensions: 2 rows × 9 columns
| UWNR | UWTEXT | UW_EINH | L/H | UWTYP | NAME | MUL | DIV | ADD |
|---|---|---|---|---|---|---|---|---|
| 0xD52E | SPANNUNG_KL15_GZA | V | High | unsigned char | - | 1.0 | 1.0 | 0.0 |
| 0xD5E8 | LEUCHTEN_GZA_TEMP | °C | High | unsigned char | - | 1.0 | 1.0 | 0.0 |
IORTTEXTE
Dimensions: 14 rows × 3 columns
| ORT | ORTTEXT | EREIGNIS_DTC |
|---|---|---|
| 0x470004 | NVM_E_CONTROL_FAILED | 0 |
| 0x47000E | Botschaft (Fahrzeugzustand, 0x3A0) fehlt | 1 |
| 0x470007 | NVM_E_READ_FAILED | 0 |
| 0x47000D | Puffer für ausgehende Fehlermeldungen ist voll | 1 |
| 0x47000A | NVM_E_WRONG_CONFIG_ID | 0 |
| 0x470011 | Thermistor Leitungsunterbrechung | 0 |
| 0x470009 | NVM_E_WRITE_FAILED | 0 |
| 0x470008 | NVM_E_WRITE_ALL_FAILED | 0 |
| 0x470005 | NVM_E_ERASE_FAILED | 0 |
| 0x47000B | Fehler konnte nach maximaler Anzahl von Versuchen nicht gesendet werden | 1 |
| 0x470006 | NVM_E_READ_ALL_FAILED | 0 |
| 0x47000F | Signal (Zeit_Sekunde_Zaehler_Relativ, 0x328): ungültig | 1 |
| 0x470010 | Thermistor Kurzschluss | 0 |
| 0xFFFFFF | unbekannter Fehlerort | 0 |
IDETAILSTRUKTUR
Dimensions: 4 rows × 2 columns
| NAME | TYP |
|---|---|
| F_UWB_ERW | ja |
| SAE_CODE | nein |
| F_HLZ | ja |
| F_SEVERITY | nein |
IUMWELTTEXTE
Dimensions: 2 rows × 9 columns
| UWNR | UWTEXT | UW_EINH | L/H | UWTYP | NAME | MUL | DIV | ADD |
|---|---|---|---|---|---|---|---|---|
| 0xD52E | SPANNUNG_KL15_GZA | V | High | unsigned char | - | 1.0 | 1.0 | 0.0 |
| 0xD5E8 | LEUCHTEN_GZA_TEMP | °C | High | unsigned char | - | 1.0 | 1.0 | 0.0 |
SG_FUNKTIONEN
Dimensions: 13 rows × 16 columns
| ARG | ID | RESULTNAME | INFO | EINHEIT | LABEL | L/H | DATENTYP | NAME | MUL | DIV | ADD | SG_ADR | SERVICE | ARG_TABELLE | RES_TABELLE |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LEUCHTEN_FUNKTIONSCHECK_GZA | 0xA537 | - | Funktionstest für GZA Scheinwerfer | - | - | - | - | - | - | - | - | - | 31 | - | RES_0xA537 |
| LEUCHTEN_GZA_POSITION | 0xD5D9 | - | Status / Steuern GZA Positon | - | - | - | - | - | - | - | - | - | 2E;22 | ARG_0xD5D9 | RES_0xD5D9 |
| LEUCHTEN_GZA_REFERENZLAUF | 0xD5E3 | - | STATUS/STEUERN Referenzlauf | - | - | - | - | - | - | - | - | - | 22;2E | ARG_0xD5E3 | RES_0xD5E3 |
| LEUCHTEN_GZA_LED | 0xD5E7 | - | STATUS/STEUERN LED | - | - | - | - | - | - | - | - | - | 2E;22 | ARG_0xD5E7 | RES_0xD5E7 |
| LEUCHTEN_GZA_TEMP | 0xD5E8 | STAT_GZA_TEMP_WERT | Auslesen der Temperatur | °C | - | high | int | - | 1.0 | 1.0 | 0.0 | - | 22 | - | - |
| LEUCHTEN_SPOTLIGHT | 0xD62F | - | Aktivierung / Deaktivierung Funktion Sporlight zur Scheinwerfereinstellung | - | - | - | - | - | - | - | - | - | 2E | ARG_0xD62F | - |
| GZA_FASTA_ANZ_ANLEUCHTEREIGNISSE | 0x2300 | STAT_ANLEUCHTEREIGNISSE_WERT | Anzahl Anleuchtereignisse | - | - | high | unsigned int | - | 1.0 | 1.0 | 0.0 | - | 22 | - | - |
| GZA_FASTA_SPOT_LEUCHTDAUER | 0x2301 | STAT_SPOT_LEUCHTDAUER_WERT | Leuchtdauer des Spotlichts in Sekunden | s | - | high | unsigned long | - | 1.0 | 1.0 | 0.0 | - | 22 | - | - |
| GZA_FASTA_DL_LEUCHTDAUER | 0x2302 | STAT_DL_LEUCHTDAUER_WERT | Leuchtdauer der Designleuchte in Minuten | min | - | high | unsigned long | - | 1.0 | 1.0 | 0.0 | - | 22 | - | - |
| GZA_FASTA_TEMPERATUR_HISTO | 0x2303 | STAT_TEMPERATUR_HISTO_DATA | Histogramm der Temperatur: Byte [0...2]: Temperaturband -40...-20°C (in Minuten) Byte [3...5]: Temperaturband -20....0°C (in Minuten) Byte [6...8]: Temperaturband 0...40°C (in Minuten) Byte [9...11]: Temperaturband 40...60°C (in Minuten) Byte [12...14]: Temperaturband 60...80°C (in Minuten) Byte [0...3]: Temperaturband > 80°C (in Minuten) | DATA | - | high | data[18] | - | 1.0 | 1.0 | 0.0 | - | 22 | - | - |
| GZA_WANDELN_L_NACH_R | 0x4000 | - | Das GZA SG wird ab Werk als linkes Modul ausgeliefert. Vor dem Verbau im Fahrzeug müssen die SG in der rechten Leuchte mit diesem Dienst auf die Diagnoseadresse 0x47 umgestellt werden. | - | - | - | - | - | - | - | - | - | 2E | ARG_0x4000 | - |
| GZA_SPOTLIGHT_BINCLASS | 0x4001 | - | Helligkeitsklasse des Spotlight | - | - | - | - | - | - | - | - | - | 22;2E | ARG_0x4001 | RES_0x4001 |
| GZA_DESIGNLIGHT_BINCLASS | 0x4002 | - | Helligkeitsklasse der Designleuchte | - | - | - | - | - | - | - | - | - | 22;2E | ARG_0x4002 | RES_0x4002 |
DM_TAB_ROE_ACTIVATED_DOP
Dimensions: 2 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | Aktive Fehlermeldung deaktiviert |
| 1 | Aktive Fehlermeldung aktiviert |
RDTCI_LEV_DOP
Dimensions: 9 rows × 2 columns
| WERT | TEXT |
|---|---|
| 2 | reportDTCByStatusMask |
| 4 | reportDTCsnapshotRecordByDTCnumber |
| 6 | reportDTCextendedDataRecordByDTCnumber |
| 7 | reportNumberOfDTCbySeverityMaskRecord |
| 8 | reportDTCbySeverityMaskRecord |
| 9 | reportSeverityInformationOfDTC |
| 10 | reportSupportedDTC |
| 18 | reportNumberOfEmissionsRelatedOBDDTCByStatusMask |
| 19 | reportEmissionsRelatedOBDDTCByStatusMask |
FEHLERKLASSE_DOP
Dimensions: 4 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | Keine Fehlerklasse verfuegbar |
| 1 | Ueberpruefung beim naechsten Werkstattbesuch |
| 2 | Ueberpruefung beim naechsten Halt |
| 4 | Ueberpruefung sofort erforderlich |
PROG_DEP_DOP
Dimensions: 6 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | reserved |
| 1 | correctResult |
| 2 | incorrectResult |
| 3 | incorrectResult error SWE - HWE |
| 4 | incorrectResult error SWE - SWE |
| 255 | reserved |
SVK_VERSION_DOP
Dimensions: 2 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | reserved |
| 1 | SVKVersion_01 |
ENERGIESPARMODE_DOP
Dimensions: 4 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | Normalmode |
| 1 | Fertigungsmode |
| 2 | Transportmode |
| 3 | Flashmode |
RDBI_ADS_DOP
Dimensions: 8 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | ISOSAEReserved_00 |
| 1 | defaultSession |
| 2 | programmingSession |
| 3 | extendedDiagnosticSession |
| 4 | safetySystemDiagnosticSession |
| 64 | vehicleManufacturerSpecific_40 |
| 65 | codingSession |
| 66 | SWTSession |
RDBI_PC_PCS_DOP
Dimensions: 3 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | ECUMehrmalsProgrammierbar |
| 1 | ECUMindestensEinmalVollstaendigProgrammierbar |
| 2 | ECUNichtMehrProgrammierbar |
EXTENDED_ENERGY_MODE_DOP
Dimensions: 16 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | Erweiterter Betriebsmodus nicht gesetzt |
| 1 | Erweiterter Betriebsmodus 1 |
| 2 | Erweiterter Betriebsmodus 2 |
| 3 | Erweiterter Betriebsmodus 3 |
| 4 | Erweiterter Betriebsmodus 4 |
| 5 | Erweiterter Betriebsmodus 5 |
| 6 | Erweiterter Betriebsmodus 6 |
| 7 | Erweiterter Betriebsmodus 7 |
| 8 | Erweiterter Betriebsmodus 8 |
| 9 | Erweiterter Betriebsmodus 9 |
| 10 | Erweiterter Betriebsmodus 10 |
| 11 | Erweiterter Betriebsmodus 11 |
| 12 | Erweiterter Betriebsmodus 12 |
| 13 | Erweiterter Betriebsmodus 13 |
| 14 | Erweiterter Betriebsmodus 14 |
| 15 | Erweiterter Betriebsmodus 15 |
ARG_0XD5D9
Dimensions: 2 rows × 12 columns
| ARG | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|
| HOR_POSITION | ° | high | unsigned char | - | - | 1.0 | 0.1 | 125.0 | -12.5 | 3.0 | Horizontale Position in Grad in Fahrtrichtung links positiv, rechts negativ |
| HOR_GESCHW | °/s | high | unsigned char | - | - | 1.0 | 1.0 | 0.0 | 1.0 | 18.0 | Horizontale Geschwindigkeit |
ARG_0XD5E3
Dimensions: 1 rows × 12 columns
| ARG | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|
| AKTION | - | high | unsigned char | - | - | 1.0 | 1.0 | 0.0 | - | - | Start Referenzlauf Schrittmotor |
ARG_0XD5E7
Dimensions: 3 rows × 12 columns
| ARG | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|
| LED | 0-n | high | unsigned char | - | TAB_GZA_LED | 1.0 | 1.0 | 0.0 | - | - | Vorgabe GZA Beleuchtung. |
| DIMMUNG | % | high | unsigned char | - | - | 1.0 | 1.0 | 0.0 | - | - | Angabe der Helligkeit in % |
| ZEIT | s | high | unsigned char | - | - | 1.0 | 1.0 | 0.0 | 0.0 | 30.0 | Ansteuerzeit in Sekunden |
ARG_0XD62F
Dimensions: 2 rows × 12 columns
| ARG | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|
| FUNKTION_SPOTLIGHT | % | high | unsigned char | - | - | 1.0 | 1.0 | 0.0 | 0.0 | 100.0 | Spotlight ein, durch Vorgabe Prozentwert (1...100%) Spotlight aus, durch Vorgabe Prozentwert (0%) |
| HOR_POSITION | ° | high | unsigned char | - | - | 1.0 | 0.1 | 125.0 | -12.5 | 3.0 | Horizontale Position in Grad in Fahrtrichtung links positiv, rechts negativ |
RES_0XA537
Dimensions: 4 rows × 13 columns
| RESULTNAME | STR | STPR | RRR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| STAT_FUNKTIONSTEST_DESIGNLEUCHTE | - | - | + | 0/1 | high | unsigned char | - | - | - | - | - | Ergebnis Funktionstest: 1: kein Fehler 0: Fehler |
| STAT_FUNKTIONSTEST_SPOTLIGHT | - | - | + | 0/1 | high | unsigned char | - | - | - | - | - | Ergebnis Funktionstest: 1: kein Fehler 0: Fehler |
| STAT_FUNKTIONSTEST_SCHRITTMOTOR | - | - | + | 0/1 | high | unsigned char | - | - | - | - | - | Ergebnis Funktionstest: 1: kein Fehler 0: Fehler |
| STAT_FUNKTIONSTEST_NTC | - | - | + | 0/1 | high | unsigned char | - | - | - | - | - | Ergebnis Funktionstest: 1: kein Fehler 0: Fehler |
RES_0XD5D9
Dimensions: 1 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_POS_HOR_WERT | ° | high | unsigned char | - | - | 0.1 | 1.0 | -12.5 | Horizontale Position in Grad in Fahrtrichtung links positiv, rechts negativ |
RES_0XD5E3
Dimensions: 1 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_GZA_REFERENZLAUF_NR | 0-n | high | unsigned char | - | TAB_GZA_REFERENZLAUF | 1.0 | 1.0 | 0.0 | Status GZA-Referenzlauf 0: nicht gestartet 1: aktiv 2: ohne Fehler abgeschlossen 3: mit Fehler abgebrochen |
RES_0XD5E7
Dimensions: 4 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_GZA_SPOTLIGHT_EIN | 0/1 | high | unsigned char | - | - | 1.0 | 1.0 | 0.0 | Status Spotlight 0: Spotlight aus 1: Spotlight ein |
| STAT_GZA_DESIGNLEUCHTE_EIN | 0/1 | high | unsigned char | - | - | 1.0 | 1.0 | 0.0 | Status Designleuchte 0: Designleuchte aus 1: Designleuchte ein |
| STAT_GZA_SPOTLIGHT_STROM_WERT | mA | high | int | - | - | 1.0 | 1.0 | 0.0 | Liefert den aktuellen Stromwert |
| STAT_GZA_DESIGNLEUCHTE_STROM_WERT | mA | high | int | - | - | 1.0 | 1.0 | 0.0 | Liefert den aktuellen Stromwert |
ARG_0X4000
Dimensions: 1 rows × 12 columns
| ARG | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|
| SEITE_R | 0/1 | high | unsigned char | - | - | - | - | - | - | - | Bei Senden mit gelöschtem Bit SEITE_R wird das Steuergerät auf die Diagnoseadresse 0x46 (Leuchte auf linker Seite) umgestellt. Das SG ist nach Ausführen des Jobs, sowie einem anschliessenden RESET (Job) nicht mehr auf Adresse 0x47 ansprechbar. |
ARG_0X4001
Dimensions: 1 rows × 12 columns
| ARG | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|
| SL_BINCLASS | 0-n | high | unsigned char | - | SL_BINCLASS_HELLIGKEIT | - | - | - | - | - | Enthält den Binning-Wert (Helligkeitsklasse) der Spotlight LED |
ARG_0X4002
Dimensions: 1 rows × 12 columns
| ARG | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|
| DL_BINCLASS_HELLIGKEIT | 0-n | high | unsigned char | - | DL_BINCLASS_HELLIGKEIT | - | - | - | - | - | Codiert die Helligkeitsgruppe der Designleuchten-LEDs. |
RES_0X4001
Dimensions: 1 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_SL_BINCLASS_HELLIGKEIT | 0-n | high | unsigned char | - | SL_BINCLASS_HELLIGKEIT | - | - | - | Die eingestellte Helligkeitsklasse der Spot-LED. |
RES_0X4002
Dimensions: 1 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_DL_BINCLASS_HELLIGKEIT | 0-n | high | unsigned char | - | DL_BINCLASS_HELLIGKEIT | - | - | - | Gibt die codierte Helligkeitsgruppe der Designleuchten-LEDs zurück |
TAB_GZA_LED
Dimensions: 4 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00 | Designleuchte aktvieren |
| 0x01 | Spotlight aktivieren |
| 0x02 | Designleuchte und Spotlight aktivieren |
| 0x03 | Designleuchte und Spotlight deaktivieren |
DL_BINCLASS_HELLIGKEIT
Dimensions: 3 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | AA |
| 1 | AB |
| 2 | BA |
SL_BINCLASS_HELLIGKEIT
Dimensions: 4 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0 | 5P |
| 1 | 6P |
| 2 | 7P |
| 3 | 8P |
TAB_GZA_REFERENZLAUF
Dimensions: 5 rows × 2 columns
| WERT | TEXT |
|---|---|
| 0x00 | Referenzlauf nicht gestartet |
| 0x01 | Referenzlauf aktiv |
| 0x02 | Referenzlauf ohne Fehler abgeschlossen |
| 0x03 | Referenzlauf mit Fehler abgebrochen |
| 0xFF | ungültiger Wert |