hsr_01.prg
INFO
| Field | Value |
|---|---|
| ECU | Hinterachse Schräglauf-Regelung |
| ORIGIN | BMW EF-611 Feneberg |
| REVISION | 2.019 |
| AUTHOR | VOLKE IT Zlatkovic |
| COMMENT | N/A |
| PACKAGE | 1.11 |
| SPRACHE | deutsch |
Jobs
Index
- INFO - Information SGBD
- INITIALISIERUNG - Initialisierung und Kommunikationsparameter
- IDENT - Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
- FS_LESEN - Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
- FS_LESEN_DETAIL - Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
- FS_LOESCHEN - Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
- PRUEFSTEMPEL_LESEN - Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
- PRUEFSTEMPEL_SCHREIBEN - Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
- SVK_LESEN - Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
- STATUS_LESEN - Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
- STEUERN - Vorgeben eines Status UDS : $2E WriteDataByIdentifier
- SERIENNUMMER_LESEN - Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
- STEUERN_ROUTINE - Vorgeben eines Status UDS : $31 RoutineControl
- FS_SPERREN - Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
- IS_LESEN - Sekundaerer Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $22 ReadDataByIdentifierRequestServiceID UDS : $2000 DataIdentifier sekundaerer Fehlerspeicher Modus: Default
- IS_LESEN_DETAIL - sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $22 ReadDataByIdentifier UDS : $20 dataIdentifier UDS : $00 alle Info-Meldungen anschließend UDS : $20 dataIdentifier UDS : $nn Details zur Info-Meldung an der Position n Modus: Default
- IS_LOESCHEN - Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default
- HERSTELLINFO_LESEN - Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
- DIAGNOSE_AUFRECHT - Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
- DIAGNOSE_MODE - SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
- ENERGIESPARMODE - Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
- STATUS_ENERGIESPARMODE - Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
- STATUS_BETRIEBSMODE - Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default
- STEUERN_BETRIEBSMODE - Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default
- STEUERGERAETE_RESET - Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
- STEUERN_ROE_STOP - Temporaeres Deaktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $00 Stop $02 (EventWindowTime)
- STATUS_ROE_REPORT - Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $04 report activated events
- STEUERN_ROE_START - Temporaeres Aktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $05 Start $02 (EventWindowTime)
- STEUERN_ROE_PERSISTENT_STOP - Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime)
- STEUERN_ROE_PERSISTENT_START - Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime)
- CPS_LESEN - Codierpruefstempel lesen UDS : $22 ReadDataByIdentifier UDS : $37FE DataIdentifier Codierpruefstempel Modus: Default
- DIAG_SESSION_LESEN - Aktive Diagnose-Session auslesen UDS : $22 ReadDataByIdentifier UDS : $F186 ActiveDiagnosticSession Modus: Default
- FLASH_TP_LESEN - Flash Timing Parameter auslesen UDS : $22 ReadDataByIdentifier UDS : $2504 FlashTimingParameter Modus: Default
- PROG_ZAEHLER_LESEN - Programmierzaehler lesen UDS : $22 ReadDataByIdentifier UDS : $2502 ProgrammingCounter Modus: Default
- PROG_MAX_LESEN - Anzahl der maximal möglichen Programmiervorgänge auslesen UDS : $22 ReadDataByIdentifier UDS : $2503 ProgrammingCounter Modus: Default
INFO
Information SGBD
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| ECU | string | Steuergerät im Klartext |
| ORIGIN | string | Steuergeräte-Verantwortlicher |
| REVISION | string | Versions-Nummer |
| AUTHOR | string | Namen aller Autoren |
| COMMENT | string | wichtige Hinweise |
| PACKAGE | string | Include-Paket-Nummer |
| SPRACHE | string | deutsch, english |
INITIALISIERUNG
Initialisierung und Kommunikationsparameter
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| DONE | int | 1, wenn Okay |
IDENT
Identdaten UDS : $22 ReadDataByIdentifier UDS : $F150 Sub-Parameter SGBD-Index Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| ID_SG_ADR | long | Steuergeraeteadresse |
| ID_SGBD_INDEX | long | Index zur Erkennung der SG-Variante |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FS_LESEN
Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $02 ReadDTCByStatusMask UDS : $0C StatusMask (Bit2, Bit3) Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FS_LESEN_DETAIL
Fehlerspeicher lesen (einzelner Fehler / Ort und Art) UDS : $19 ReadDTCInformation UDS : $04 reportDTCSnapshotRecordByDTCNumber UDS : $06 reportDTCExtendedDataRecordByDTCNumber UDS : $09 reportSeverityInformationOfDTC Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| F_CODE | long | gewaehlter Fehlercode |
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_HFK | int | Haufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf |
| F_HLZ | int | Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Haufigkeitszaehler |
| F_UEBERLAUF | int | 0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers |
| F_FEHLERKLASSE_NR | int | 0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich ! |
| F_FEHLERKLASSE_TEXT | string | Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT |
| F_UW_ANZ | int | Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung |
| F_UW_KM | long | Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht |
| F_UW_ZEIT | long | Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_SAE_CODE | unsigned int | Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD |
| F_SAE_CODE_STRING | string | 5 stelliger Text in der Form 'Sxxxx' |
| F_SAE_CODE_TEXT | string | Text zu F_SAE_CODE |
| _RESPONSE_SNAPSHOT | binary | Hex-Antwort von SG |
| _RESPONSE_EXTENDED_DATA | binary | Hex-Antwort von SG |
| _RESPONSE_SEVERITY | binary | Hex-Antwort von SG |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
FS_LOESCHEN
Fehlerspeicher loeschen UDS : $14 ClearDiagnosticInformation UDS : $FF DTCHighByte UDS : $FF DTCMiddleByte UDS : $FF DTCLowByte Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| F_CODE | long | 0x??????: Angabe eines einzelnen Fehlers Default: 0xFFFFFF: alle Fehler |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PRUEFSTEMPEL_LESEN
Auslesen des Pruefstempels UDS : $22 ReadDataByIdentifier UDS : $1000 TestStamp Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| BYTE1 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE2 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE3 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PRUEFSTEMPEL_SCHREIBEN
Beschreiben des Pruefstempels Es muessen immer alle drei Argumente im Bereich von 0-255 bzw. 0x00-0xFF uebergeben werden. UDS : $2E WriteDataByIdentifier UDS : $1000 TestStamp Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| BYTE1 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE2 | int | Bereich: 0-255 bzw. 0x00-0xFF |
| BYTE3 | int | Bereich: 0-255 bzw. 0x00-0xFF |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
SVK_LESEN
Informationen zur Steuergeraete-Verbau-Kennung UDS : $22 ReadDataByIdentifier UDS : $F1xx Sub-Parameter fuer SVK UDS : $F101 SVK_AKTUELL (Default) Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| SVK | string | table SVK_ID BEZEICHNUNG WERT default SVK_AKTUELL |
Results
| Name | Type | Comment |
|---|---|---|
| PROG_TEST | int | Programmierabhaengigkeiten (ProgrammingDependenciesChecked) 1: IO : Signaturpruefung und ProgrammingDependenciesCheck erfolgreich 2: NIO: mindestens eine SWE fehlerhaft oder ProgrammingDependenciesCheck nicht durchgefuehrt 3: NIO: mindestens eine SWE passt nicht mit einer HWE zusammen 4: NIO: mindestens eine SWE passt nicht mit einer anderen SWE zusammen sonst: reserviert |
| ANZAHL_EINHEITEN | int | Anzahl der xWEn |
| PROG_DATUM | string | Programmierdatum (DD.MM.YY) |
| PROG_KM | long | KM-Stand bei Programmierung (10 KM bis 655350 KM) Inkrement sind 10 KM -1: KM-Stand wird nicht unterstuetzt |
| PROZESSKLASSE_WERT | int | table Prozessklassen WERT dezimale Angabe der Prozessklasse |
| PROZESSKLASSE_TEXT | string | table Prozessklassen BEZEICHNUNG Text-Angabe der Prozessklasse |
| PROZESSKLASSE_KURZTEXT | string | table Prozessklassen PROZESSKLASSE Text-Angabe des Prozessklassenkurztextes |
| SGBM_IDENTIFIER | string | Angabe SGBM-ID der Prozessklasse |
| VERSION | string | Angabe der Version der Prozessklasse |
| SGBM_ID | string | Angabe von Prozessklasse, SGBM-Identifier, Version |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_LESEN
Lesen eines oder mehrerer Stati UDS : $22 ReadDataByIdentifier
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Es muss mindestens ein Argument übergeben werden Es wird das zugehörige result erzeugt table SG_Funktionen ARG ID RESULTNAME RES_TABELLE ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN
Vorgeben eines Status UDS : $2E WriteDataByIdentifier
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Siehe table SG_Funktionen ARG ID LABEL ARG_TABELLE |
| WERT | string | Es muss mindestens ein Argument übergeben werden Argumente siehe table SG_Funktionen ARG ID ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
SERIENNUMMER_LESEN
Seriennummer des Steuergeraets UDS : $22 ReadDataByIdentifier UDS : $F18C Sub-Parameter ECUSerialNumber Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| SERIENNUMMER | string | Seriennummer des Steuergeraets |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROUTINE
Vorgeben eines Status UDS : $31 RoutineControl
Arguments
| Name | Type | Comment |
|---|---|---|
| ARGUMENT_SPALTE | string | 'ARG', 'ID', 'LABEL' |
| STATUS | string | Siehe table SG_Funktionen ARG ID RES_TABELLE ARG_TABELLE |
| STEUERPARAMETER | string | 'STR' = startRoutine 'STPR' = stopRoutine 'RRR' = requestRoutineResults |
| WERT | string | Argumente siehe table SG_Funktionen ARG_TABELLE |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Antwort von SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FS_SPERREN
Sperren bzw. Freigeben des Fehlerspeichers UDS : $85 ControlDTCSetting UDS : $?? Sperren ($02) / Freigabe ($01) Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| SPERREN | string | "ja" -> Fehlerspeicher sperren "nein" -> Fehlerspeicher freigeben table DigitalArgument TEXT Default: "ja" |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
IS_LESEN
Sekundaerer Fehlerspeicher lesen (alle Fehler / Ort und Art) UDS : $22 ReadDataByIdentifierRequestServiceID UDS : $2000 DataIdentifier sekundaerer Fehlerspeicher Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
IS_LESEN_DETAIL
sekundären Fehlerspeicher lesen (Info-Meldungen / Ort und Art) UDS : $22 ReadDataByIdentifier UDS : $20 dataIdentifier UDS : $00 alle Info-Meldungen anschließend UDS : $20 dataIdentifier UDS : $nn Details zur Info-Meldung an der Position n Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| F_CODE | long | gewaehlter Infocode Wenn dieser Parameter angegeben wird, wird die Position automatisch ermittelt. Es darf dann nicht argument F_POS angegeben werden |
| F_POS | int | gewaehlter Eintrag Wenn dieser Parameter angegeben wird, wird die Position benutzt. Wertebereich 1 - 255 Es darf dann nicht argument F_CODE angegeben werden |
Results
| Name | Type | Comment |
|---|---|---|
| F_VERSION | int | Typ des Fehlerspeichers Fuer UDS immer 3 |
| F_HEX_CODE | binary | Fehlerdaten pro Fehler als Hexcode |
| F_ORT_NR | long | Index fuer Fehlerort |
| F_ORT_TEXT | string | Fehlerort als Text table FOrtTexte ORTTEXT |
| F_EREIGNIS_DTC | int | 0: DTC kein Ereignis DTC 1: DTC ist Ereignis DTC table FOrtTexte EREIGNIS_DTC |
| F_READY_NR | int | Readyness Flag (Standard-Fehlerart) als Zahl |
| F_READY_TEXT | string | Readyness Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_VORHANDEN_NR | int | Fehler vorhanden (Standard-Fehlerart) als Zahl |
| F_VORHANDEN_TEXT | string | Fehler vorhanden (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_WARNUNG_NR | int | Warnlampen Flag (Standard-Fehlerart) als Zahl |
| F_WARNUNG_TEXT | string | Warnlampen Flag (Standard-Fehlerart) als Text table FArtTexte ARTTEXT |
| F_HFK | int | Haufigkeitszaehler als Zahl Wertebereich 0 - 255 Bei mehr als 255 bleibt Zaehler stehen. Kein Ueberlauf |
| F_HLZ | int | Heilungsszaehler als Zahl Wertebereich 0 - 255 -1: ohne Haufigkeitszaehler |
| F_UEBERLAUF | int | 0: Kein Ueberlauf des Fehlerspeichers 1: Ueberlauf des Fehlerspeichers |
| F_FEHLERKLASSE_NR | int | 0: Keine Fehlerklasse verfuegbar 1: Ueberpruefung bei naechstem Werkstattbesuch 2: Ueberpruefung bei naechstem Halt 4: Ueberpruefung sofort erforderlich ! |
| F_FEHLERKLASSE_TEXT | string | Ausgabe der Fehlerklasse als Text table Fehlerklasse TEXT |
| F_UW_ANZ | int | Anzahl der Umweltbedingungen Je nach dieser Anzahl i (i = 1, 2, ...) existieren i mal folgende Results: (long) F_UWi_NR Index der i. Umweltbedingung (string) F_UWi_TEXT Text zur i. Umweltbedingung (real) F_Uwi_WERT Wert der i. Umweltbedingung (string) F_UWi_EINH Einheit der i. Umweltbedingung |
| F_UW_KM | long | Umweltbedingung Kilometerstand (3 Byte) Wertebereich: 0 - 16777215 km -1, wenn Kilometerstand nicht zur Verfuegung steht |
| F_UW_ZEIT | long | Umweltbedingung Absolute Zeit (4 Byte) Genauigkeit: in Sekunden -1, wenn Absolute Zeit nicht zur Verfuegung steht |
| F_SAE_CODE | unsigned int | Wertebereich 0x000000 - 0xFFFFFF externe Tabelle T_SCOD |
| F_SAE_CODE_STRING | string | 5 stelliger Text in der Form 'Sxxxx' |
| F_SAE_CODE_TEXT | string | Text zu F_SAE_CODE |
| _RESPONSE_2000 | binary | Hex-Antwort von SG |
| _RESPONSE_200X | binary | Hex-Antwort von SG |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
IS_LOESCHEN
Infospeicher loeschen UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $0F06 ClearSecondaryDTCMemory Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
HERSTELLINFO_LESEN
Lieferant und Herstelldatum lesen UDS : $22 ReadDataByIdentifier UDS : $F18A SystemSupplierIdentifier UDS : $F18B ECUManufactoringData Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| ID_LIEF_NR | long | Lieferantennummer 0xFFFFFF, falls nicht vorhanden |
| ID_LIEF_TEXT | string | Text zu ID_LIEF_NR table Lieferanten LIEF_TEXT unbekannter Hersteller, falls nicht vorhanden |
| ID_DATUM | string | Herstelldatum (DD.MM.YY) |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
| _REQUEST_2 | binary | Hex-Auftrag an SG |
| _RESPONSE_2 | binary | Hex-Antwort von SG |
DIAGNOSE_AUFRECHT
Diagnosemode des SG aufrecht erhalten UDS : $3E TesterPresent UDS : $?0 suppressPosRspMsgIndication Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| SG_ANTWORT | string | "ja" -> SG soll antworten "nein" -> SG soll nicht antworten table DigitalArgument TEXT Default: SG soll antworten |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
DIAGNOSE_MODE
SG in bestimmten Diagnosemode bringen UDS : $10 StartDiagnosticSession Modus: einstellbar mit diesem Job
Arguments
| Name | Type | Comment |
|---|---|---|
| MODE | string | gewuenschter Diagnose-Modus table DiagMode MODE MODE_TEXT Defaultwert: DEFAULT (DefaultMode) |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
ENERGIESPARMODE
Einstellen des Energiesparmodes UDS : $31 RoutineControlRequestServiceID UDS : $01 startRoutine UDS : $0F0C DataIdentifier ControlEnergySavingMode UDS : $?? Mode Modus : Default
Arguments
| Name | Type | Comment |
|---|---|---|
| MODE | int | 0x00: Normalmode 0x01: Fertigungsmode 0x02: Transportmode 0x03: Flashmode |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_ENERGIESPARMODE
Energy-Saving-Mode auslesen UDS : $22 ReadDataByIdentifier UDS : $100A DataIdentifier EnergySavingMode Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_ENERGIESPARMODE_WERT | int | Ausgabe des Energiesparmodes 0: Kein Energiesparmode gesetzt 1: Produktionsmode gesetzt 2: Transportmode gesetzt 3: Flashmode gesetzt -1: Mode ungueltig |
| STAT_ENERGIESPARMODE_TEXT | string | Text zu STAT_ENERGIESPARMODE_WERT |
| STAT_PRODUKTIONSMODE_EIN | int | 0: Produktionsmode nicht aktiv 1: Produktionsmode aktiv |
| STAT_TRANSPORTMODE_EIN | int | 0: Transportmode nicht aktiv 1: Transportmode aktiv |
| STAT_FLASHMODE_EIN | int | 0: Flashmode nicht aktiv 1: Flashmode aktiv |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_BETRIEBSMODE
Aktueller Betriebsmode SG muss sich im Energiersparmode befinden UDS : $22 ReadDataByIdentifier UDS : $100E Sub-Parameter Betriebsmode Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_BETRIEBSMODE_WERT | int | Aktueller Betriebsmode table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle) |
| STAT_BETRIEBSMODE_TEXT | string | Textausgabe STAT_BETRIEBSMODE_WERT table Betriebsmode TEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_BETRIEBSMODE
Betriebsmode setzen SG muss sich im Energiersparmode befinden UDS : $31 RoutineControl UDS : $01 startRoutine UDS : $1003 DataIdentifier Betriebsmode UDS : $0? Betriebsmode Modus: Default
Arguments
| Name | Type | Comment |
|---|---|---|
| BETRIEBSMODE | int | Betriebsmode setzen table Betriebsmode WERT 0 : Kein Betriebsmode gesetzt 1 - 16: Erweiterter Betriebsmode (Bedeutung siehe Tabelle) |
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERGERAETE_RESET
Harter Reset des Steuergeraets UDS : $11 EcuReset UDS : $01 HardReset Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_STOP
Temporaeres Deaktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $00 Stop $02 (EventWindowTime)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STATUS_ROE_REPORT
Abfrage Status der Aktivierung der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $04 report activated events
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| STAT_ROE_AKTIV | char | 0x00 = Aktive Fehlermeldung deaktiviert 0x01 = Aktive Fehlermeldung aktiviert 0xFF = Status der aktiven Fehlermeldung nicht feststellbar |
| STAT_ROE_AKTIV_TEXT | string | Interpretation von STAT_ROE_AKTIV table UDS_TAB_ROE_AKTIV TEXT |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_START
Temporaeres Aktivieren der aktiven Fehlermeldung UDS : $86 ResponseOnEvent $05 Start $02 (EventWindowTime)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_PERSISTENT_STOP
Persistentes Deaktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $40 Stop persistent $02 (EventWindowTime)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
STEUERN_ROE_PERSISTENT_START
Persistentes Aktivieren der aktiven Fehlermeldung an den Diagnosemaster ueber TAS UDS : $86 ResponseOnEvent $45 Start persistent $02 (EventWindowTime)
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
CPS_LESEN
Codierpruefstempel lesen UDS : $22 ReadDataByIdentifier UDS : $37FE DataIdentifier Codierpruefstempel Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| CPS | string | Codierpruefstempel 7-stellig |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
DIAG_SESSION_LESEN
Aktive Diagnose-Session auslesen UDS : $22 ReadDataByIdentifier UDS : $F186 ActiveDiagnosticSession Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| DIAG_SESSION_WERT | int | Diagnose-Session (1 Byte) |
| DIAG_SESSION_TEXT | string | Diagnose-Session als Text |
| DIAG_DETAIL_WERT | int | Details zur Diagnose-Session (1 Byte) |
| DIAG_DETAIL_TEXT | string | Details zur Diagnose-Session als Text |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
FLASH_TP_LESEN
Flash Timing Parameter auslesen UDS : $22 ReadDataByIdentifier UDS : $2504 FlashTimingParameter Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| FLASH_LOESCHEN | int | EraseMemoryTime (2 Byte) |
| FLASH_TEST | int | CheckMemoryTime (2 Byte) |
| FLASH_BOOT | int | BootloaderInstallationTime (2 Byte) |
| FLASH_AUTHENT | int | AuthenticationTime (2 Byte) |
| FLASH_RESET | int | ResetTime (2 Byte) |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PROG_ZAEHLER_LESEN
Programmierzaehler lesen UDS : $22 ReadDataByIdentifier UDS : $2502 ProgrammingCounter Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| PROG_ZAEHLER_STATUS_WERT | int | Status, wie oft das SG programmierbar ist |
| PROG_ZAEHLER_STATUS_TEXT | string | Status, wie oft das SG programmierbar ist |
| PROG_ZAEHLER | int | Programmierzaehler |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
PROG_MAX_LESEN
Anzahl der maximal möglichen Programmiervorgänge auslesen UDS : $22 ReadDataByIdentifier UDS : $2503 ProgrammingCounter Modus: Default
No arguments.
Results
| Name | Type | Comment |
|---|---|---|
| PROG_MAX | long | maximal mögliche Programmiervorgänge Sonderfall 0xFFFF: Anzahl der Programmiervorgänge unbegrenzt |
| JOB_STATUS | string | OKAY, wenn fehlerfrei table JobResult STATUS_TEXT |
| _REQUEST | binary | Hex-Auftrag an SG |
| _RESPONSE | binary | Hex-Antwort von SG |
Tables
Index
- JOBRESULT (66 × 2)
- LIEFERANTEN (115 × 2)
- FARTTEXTE (18 × 2)
- DIGITALARGUMENT (17 × 2)
- PROZESSKLASSEN (24 × 3)
- SVK_ID (65 × 2)
- DTCEXTENDEDDATARECORDNUMBER (5 × 3)
- DTCSNAPSHOTIDENTIFIER (5 × 9)
- FEHLERKLASSE (5 × 2)
- DIAGMODE (11 × 3)
- IARTTEXTE (18 × 2)
- UDS_TAB_ROE_AKTIV (3 × 2)
- JOBRESULTEXTENDED (1 × 2)
- BETRIEBSMODE (3 × 3)
- FORTTEXTE (60 × 3)
- FDETAILSTRUKTUR (6 × 2)
- FUMWELTTEXTE (5 × 9)
- IORTTEXTE (186 × 3)
- IDETAILSTRUKTUR (4 × 2)
- IUMWELTTEXTE (21 × 9)
- SG_FUNKTIONEN (28 × 16)
- RES_0XDBAB (6 × 10)
- RES_0XDBB0 (3 × 10)
- RES_0XDBBB (2 × 10)
- RES_0XDB88 (3 × 10)
- RES_0XDBA8 (2 × 10)
- RES_0XDBAD (8 × 10)
- ARG_0XAB94 (1 × 15)
- RES_0XAB92 (6 × 13)
- RES_0XAB94 (6 × 13)
- RES_0XDBAE (4 × 13)
- RES_0XDBBA (3 × 10)
- RES_0XDB90 (3 × 10)
- RES_0XDBB6 (3 × 10)
- RES_0XDBAA (2 × 10)
- RES_0XDBAF (9 × 13)
- TAB_STMSTATE (41 × 3)
- TAB_GSTMSTATE (13 × 3)
- TAB_MLWSTATE (5 × 3)
- TAB_PDUSTATE (6 × 3)
- TAB_VLTGSTATE (4 × 3)
- TAB_STMCM (7 × 3)
- TAB_ADSTATE (7 × 3)
- TAB_QUTARSTEA (9 × 3)
- TAB_STECUICM (17 × 3)
- RES_0X4100 (13 × 10)
- TAB_KFC (211 × 2)
- TAB_KFA (184 × 2)
- RES_0X4101 (64 × 10)
- RES_0X4103 (1 × 13)
- ARG_0X4103 (5 × 14)
- TAB_EEEERR (14 × 3)
- RES_0X4104 (12 × 13)
JOBRESULT
Dimensions: 66 rows × 2 columns
| SB | STATUS_TEXT |
|---|---|
| 0x10 | ERROR_ECU_GENERAL_REJECT |
| 0x11 | ERROR_ECU_SERVICE_NOT_SUPPORTED |
| 0x12 | ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED |
| 0x13 | ERROR_ECU_INCORRECT_MESSAGE_LENGTH_OR_INVALID_FORMAT |
| 0x14 | ERROR_ECU_RESPONSE_TOO_LONG |
| 0x21 | ERROR_ECU_BUSY_REPEAT_REQUEST |
| 0x22 | ERROR_ECU_CONDITIONS_NOT_CORRECT |
| 0x24 | ERROR_ECU_REQUEST_SEQUENCE_ERROR |
| 0x25 | ERROR_ECU_NO_RESPONSE_FROM_SUBNET_COMPONENT |
| 0x26 | ERROR_ECU_FAILURE_PREVENTS_EXECUTION_OF_REQUESTED_ACTION |
| 0x31 | ERROR_ECU_REQUEST_OUT_OF_RANGE |
| 0x33 | ERROR_ECU_SECURITY_ACCESS_DENIED |
| 0x35 | ERROR_ECU_INVALID_KEY |
| 0x36 | ERROR_ECU_EXCEED_NUMBER_OF_ATTEMPTS |
| 0x37 | ERROR_ECU_REQUIRED_TIME_DELAY_NOT_EXPIRED |
| 0x70 | ERROR_ECU_UPLOAD_DOWNLOAD_NOT_ACCEPTED |
| 0x71 | ERROR_ECU_TRANSFER_DATA_SUSPENDED |
| 0x72 | ERROR_ECU_GENERAL_PROGRAMMING_FAILURE |
| 0x73 | ERROR_ECU_WRONG_BLOCK_SEQUENCE_COUNTER |
| 0x78 | ERROR_ECU_REQUEST_CORRECTLY_RECEIVED__RESPONSE_PENDING |
| 0x7E | ERROR_ECU_SUB_FUNCTION_NOT_SUPPORTED_IN_ACTIVE_SESSION |
| 0x7F | ERROR_ECU_SERVICE_NOT_SUPPORTED_IN_ACTIVE_SESSION |
| 0x81 | ERROR_ECU_RPM_TOO_HIGH |
| 0x82 | ERROR_ECU_RPM_TOO_LOW |
| 0x83 | ERROR_ECU_ENGINE_IS_RUNNING |
| 0x84 | ERROR_ECU_ENGINE_IS_NOT_RUNNING |
| 0x85 | ERROR_ECU_ENGINE_RUN_TIME_TOO_LOW |
| 0x86 | ERROR_ECU_TEMPERATURE_TOO_HIGH |
| 0x87 | ERROR_ECU_TEMPERATURE_TOO_LOW |
| 0x88 | ERROR_ECU_VEHICLE_SPEED_TOO_HIGH |
| 0x89 | ERROR_ECU_VEHICLE_SPEED_TOO_LOW |
| 0x8A | ERROR_ECU_THROTTLE_PEDAL_TOO_HIGH |
| 0x8B | ERROR_ECU_THROTTLE_PEDAL_TOO_LOW |
| 0x8C | ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_NEUTRAL |
| 0x8D | ERROR_ECU_TRANSMISSION_RANGE_NOT_IN_GEAR |
| 0x8F | ERROR_ECU_BRAKE_SWITCH_NOT_CLOSED |
| 0x90 | ERROR_ECU_SHIFTER_LEVER_NOT_IN_PARK |
| 0x91 | ERROR_ECU_TORQUE_CONVERTER_CLUTCH_LOCKED |
| 0x92 | ERROR_ECU_VOLTAGE_TOO_HIGH |
| 0x93 | ERROR_ECU_VOLTAGE_TOO_LOW |
| ?00? | OKAY |
| ?01? | ERROR_ECU_NO_RESPONSE |
| ?02? | ERROR_ECU_INCORRECT_LEN |
| ?03? | ERROR_ECU_INCORRECT_RESPONSE_ID |
| ?04? | ERROR_ECU_TA_RESPONSE_NOT_SA_REQUEST |
| ?05? | ERROR_ECU_SA_RESPONSE_NOT_TA_REQUEST |
| ?06? | ERROR_ECU_RESPONSE_INCORRECT_DATA_IDENTIFIER |
| ?07? | ERROR_ECU_RESPONSE_TOO_MUCH_DATA |
| ?08? | ERROR_ECU_RESPONSE_TOO_LESS_DATA |
| ?09? | ERROR_ECU_RESPONSE_VALUE_OUT_OF_RANGE |
| ?0A? | ERROR_TABLE |
| ?10? | ERROR_F_CODE |
| ?12? | ERROR_INTERPRETATION |
| ?13? | ERROR_F_POS |
| ?14? | ERROR_ECU_RESPONSE_INCORRECT_IO_CONTROL_PARAMETER |
| ?15? | ERROR_ECU_RESPONSE_INCORRECT_ROUTINE_CONTROL_TYPE |
| ?16? | ERROR_ECU_RESPONSE_INCORRECT_SUB_FUNCTION |
| ?17? | ERROR_ECU_RESPONSE_INCORRECT_DYNAMICALLY_DEFINED_DATA_IDENTIFIER |
| ?18? | ERROR_ECU_RESPONSE_NO_STRING_END_CHAR |
| ?50? | ERROR_BYTE1 |
| ?51? | ERROR_BYTE2 |
| ?52? | ERROR_BYTE3 |
| ?80? | ERROR_SVK_INCORRECT_LEN |
| ?81? | ERROR_SVK_INCORRECT_FINGERPRINT |
| ?F0? | ERROR_ARGUMENT |
| 0xXY | ERROR_ECU_UNKNOWN_NEGATIVE_RESPONSE |
LIEFERANTEN
Dimensions: 115 rows × 2 columns
| LIEF_NR | LIEF_TEXT |
|---|---|
| 0x000001 | Reinshagen => Delphi |
| 0x000002 | Kostal |
| 0x000003 | Hella |
| 0x000004 | Siemens |
| 0x000005 | Eaton |
| 0x000006 | UTA |
| 0x000007 | Helbako |
| 0x000008 | Bosch |
| 0x000009 | Loewe => Lear |
| 0x000010 | VDO |
| 0x000011 | Valeo |
| 0x000012 | MBB |
| 0x000013 | Kammerer |
| 0x000014 | SWF |
| 0x000015 | Blaupunkt |
| 0x000016 | Philips |
| 0x000017 | Alpine |
| 0x000018 | Continental Teves |
| 0x000019 | Elektromatik Suedafrika |
| 0x000020 | Becker |
| 0x000021 | Preh |
| 0x000022 | Alps |
| 0x000023 | Motorola |
| 0x000024 | Temic |
| 0x000025 | Webasto |
| 0x000026 | MotoMeter |
| 0x000027 | Delphi PHI |
| 0x000028 | DODUCO => BERU |
| 0x000029 | DENSO |
| 0x000030 | NEC |
| 0x000031 | DASA |
| 0x000032 | Pioneer |
| 0x000033 | Jatco |
| 0x000034 | Fuba |
| 0x000035 | UK-NSI |
| 0x000036 | AABG |
| 0x000037 | Dunlop |
| 0x000038 | Sachs |
| 0x000039 | ITT |
| 0x000040 | FTE |
| 0x000041 | Megamos |
| 0x000042 | TRW |
| 0x000043 | Wabco |
| 0x000044 | ISAD Electronic Systems |
| 0x000045 | HEC (Hella Electronics Corporation) |
| 0x000046 | Gemel |
| 0x000047 | ZF |
| 0x000048 | GMPT |
| 0x000049 | Harman Kardon |
| 0x000050 | Remes |
| 0x000051 | ZF Lenksysteme |
| 0x000052 | Magneti Marelli |
| 0x000053 | Borg Instruments |
| 0x000054 | GETRAG |
| 0x000055 | BHTC (Behr Hella Thermocontrol) |
| 0x000056 | Siemens VDO Automotive |
| 0x000057 | Visteon |
| 0x000058 | Autoliv |
| 0x000059 | Haberl |
| 0x000060 | Magna Steyr |
| 0x000061 | Marquardt |
| 0x000062 | AB-Elektronik |
| 0x000063 | Siemens VDO Borg |
| 0x000064 | Hirschmann Electronics |
| 0x000065 | Hoerbiger Electronics |
| 0x000066 | Thyssen Krupp Automotive Mechatronics |
| 0x000067 | Gentex GmbH |
| 0x000068 | Atena GmbH |
| 0x000069 | Magna-Donelly |
| 0x000070 | Koyo Steering Europe |
| 0x000071 | NSI B.V |
| 0x000072 | AISIN AW CO.LTD |
| 0x000073 | Shorlock |
| 0x000074 | Schrader |
| 0x000075 | BERU Electronics GmbH |
| 0x000076 | CEL |
| 0x000077 | Audio Mobil |
| 0x000078 | rd electronic |
| 0x000079 | iSYS RTS GmbH |
| 0x000080 | Westfalia Automotive GmbH |
| 0x000081 | Tyco Electronics |
| 0x000082 | Paragon AG |
| 0x000083 | IEE S.A |
| 0x000084 | TEMIC AUTOMOTIVE of NA |
| 0x000085 | AKsys GmbH |
| 0x000086 | META System |
| 0x000087 | Hülsbeck & Fürst GmbH & Co KG |
| 0x000088 | Mann & Hummel Automotive GmbH |
| 0x000089 | Brose Fahrzeugteile GmbH & Co |
| 0x000090 | Keihin |
| 0x000091 | Vimercati S.p.A. |
| 0x000092 | CRH |
| 0x000093 | TPO Display Corp. |
| 0x000094 | KÜSTER Automotive Control |
| 0x000095 | Hitachi Automotive |
| 0x000096 | Continental Automotive |
| 0x000097 | TI-Automotive |
| 0x000098 | Hydro |
| 0x000099 | Johnson Controls |
| 0x00009A | Takata- Petri |
| 0x00009B | Mitsubishi Electric B.V. (Melco) |
| 0x00009C | Autokabel |
| 0x00009D | GKN-Driveline |
| 0x00009E | Zollner Elektronik AG |
| 0x00009F | PEIKER acustics GmbH |
| 0x0000A0 | Bosal-Oris |
| 0x0000A1 | Cobasys |
| 0x0000A2 | Lighting Reutlingen GmbH |
| 0x0000A3 | CONTI VDO |
| 0x0000A4 | ADC Automotive Distance Control Systems GmbH |
| 0x0000A5 | Funkwerk Dabendorf GmbH |
| 0x0000A6 | Lame |
| 0x0000A7 | Magna/Closures |
| 0x0000A8 | Wanyu |
| 0xFFFFFF | unbekannter Hersteller |
FARTTEXTE
Dimensions: 18 rows × 2 columns
| ARTNR | ARTTEXT |
|---|---|
| 0x00 | keine Fehlerart verfügbar |
| 0x04 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x05 | Fehler momentan vorhanden und bereits gespeichert |
| 0x08 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x09 | Fehler momentan vorhanden und bereits gespeichert |
| 0x0C | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x0D | Fehler momentan vorhanden und bereits gespeichert |
| 0x44 | Fehler gespeichert |
| 0x45 | Fehler gespeichert |
| 0x48 | Fehler gespeichert |
| 0x49 | Fehler gespeichert |
| 0x4C | Fehler gespeichert |
| 0x4D | Fehler gespeichert |
| 0x10 | Testbedingungen erfüllt |
| 0x11 | Testbedingungen noch nicht erfüllt |
| 0x80 | Fehler würde kein Aufleuchten einer Warnlampe verursachen |
| 0x81 | Fehler würde das Aufleuchten einer Warnlampe verursachen |
| 0xFF | unbekannte Fehlerart |
DIGITALARGUMENT
Dimensions: 17 rows × 2 columns
| TEXT | WERT |
|---|---|
| ein | 1 |
| aus | 0 |
| ja | 1 |
| nein | 0 |
| auf | 1 |
| ab | 0 |
| an | 1 |
| yes | 1 |
| no | 0 |
| on | 1 |
| off | 0 |
| up | 1 |
| down | 0 |
| true | 1 |
| false | 0 |
| 1 | 1 |
| 0 | 0 |
PROZESSKLASSEN
Dimensions: 24 rows × 3 columns
| WERT | PROZESSKLASSE | BEZEICHNUNG |
|---|---|---|
| 0x00 | - | ungueltig |
| 0x01 | HWEL | Hardware (Elektronik) |
| 0x02 | HWAP | Hardwareauspraegung |
| 0x03 | HWFR | Hardwarefarbe |
| 0x05 | CAFD | Codierdaten |
| 0x06 | BTLD | Bootloader |
| 0x08 | SWFL | Software ECU Speicherimage |
| 0x09 | SWFF | Flash File Software |
| 0x0A | SWPF | Pruefsoftware |
| 0x0B | ONPS | Onboard Programmiersystem |
| 0x0F | FAFP | FA2FP |
| 0x1A | TLRT | Temporaere Loeschroutine |
| 0x1B | TPRG | Temporaere Programmierroutine |
| 0x07 | FLSL | Flashloader Slave |
| 0x0C | IBAD | Interaktive Betriebsanleitung Daten |
| 0x10 | FCFA | Freischaltcode Fahrzeug-Auftrag |
| 0x1C | BLUP | Bootloader-Update Applikation |
| 0x1D | FLUP | Flashloader-Update Applikation |
| 0xA0 | ENTD | Entertainment Daten |
| 0xA1 | NAVD | Navigation Daten |
| 0xA2 | FCFN | Freischaltcode Funktion |
| 0xC0 | SWUP | Software-Update Package |
| 0xC1 | SWIP | Index Software-Update Package |
| 0xFF | - | ungueltig |
SVK_ID
Dimensions: 65 rows × 2 columns
| WERT | BEZEICHNUNG |
|---|---|
| 0x01 | SVK_AKTUELL |
| 0x02 | SVK_SUPPLIER |
| 0x03 | SVK_WERK |
| 0x04 | SVK_BACKUP_01 |
| 0x05 | SVK_BACKUP_02 |
| 0x06 | SVK_BACKUP_03 |
| 0x07 | SVK_BACKUP_04 |
| 0x08 | SVK_BACKUP_05 |
| 0x09 | SVK_BACKUP_06 |
| 0x0A | SVK_BACKUP_07 |
| 0x0B | SVK_BACKUP_08 |
| 0x0C | SVK_BACKUP_09 |
| 0x0D | SVK_BACKUP_10 |
| 0x0E | SVK_BACKUP_11 |
| 0x0F | SVK_BACKUP_12 |
| 0x10 | SVK_BACKUP_13 |
| 0x11 | SVK_BACKUP_14 |
| 0x12 | SVK_BACKUP_15 |
| 0x13 | SVK_BACKUP_16 |
| 0x14 | SVK_BACKUP_17 |
| 0x15 | SVK_BACKUP_18 |
| 0x16 | SVK_BACKUP_19 |
| 0x17 | SVK_BACKUP_20 |
| 0x18 | SVK_BACKUP_21 |
| 0x19 | SVK_BACKUP_22 |
| 0x1A | SVK_BACKUP_23 |
| 0x1B | SVK_BACKUP_24 |
| 0x1C | SVK_BACKUP_25 |
| 0x1D | SVK_BACKUP_26 |
| 0x1E | SVK_BACKUP_27 |
| 0x1F | SVK_BACKUP_28 |
| 0x20 | SVK_BACKUP_29 |
| 0x21 | SVK_BACKUP_30 |
| 0x22 | SVK_BACKUP_31 |
| 0x23 | SVK_BACKUP_32 |
| 0x24 | SVK_BACKUP_33 |
| 0x25 | SVK_BACKUP_34 |
| 0x26 | SVK_BACKUP_35 |
| 0x27 | SVK_BACKUP_36 |
| 0x28 | SVK_BACKUP_37 |
| 0x29 | SVK_BACKUP_38 |
| 0x2A | SVK_BACKUP_39 |
| 0x2B | SVK_BACKUP_40 |
| 0x2C | SVK_BACKUP_41 |
| 0x2D | SVK_BACKUP_42 |
| 0x2E | SVK_BACKUP_43 |
| 0x2F | SVK_BACKUP_44 |
| 0x30 | SVK_BACKUP_45 |
| 0x31 | SVK_BACKUP_46 |
| 0x32 | SVK_BACKUP_47 |
| 0x33 | SVK_BACKUP_48 |
| 0x34 | SVK_BACKUP_49 |
| 0x35 | SVK_BACKUP_50 |
| 0x36 | SVK_BACKUP_51 |
| 0x37 | SVK_BACKUP_52 |
| 0x38 | SVK_BACKUP_53 |
| 0x39 | SVK_BACKUP_54 |
| 0x3A | SVK_BACKUP_55 |
| 0x3B | SVK_BACKUP_56 |
| 0x3C | SVK_BACKUP_57 |
| 0x3D | SVK_BACKUP_58 |
| 0x3E | SVK_BACKUP_59 |
| 0x3F | SVK_BACKUP_60 |
| 0x40 | SVK_BACKUP_61 |
| 0xXY | ERROR_UNKNOWN |
DTCEXTENDEDDATARECORDNUMBER
Dimensions: 5 rows × 3 columns
| WERT | TEXT | ANZ_BYTE |
|---|---|---|
| 0x00 | ISO_RESERVED | 0 |
| 0x01 | CONDITION_BYTE | 1 |
| 0x02 | HFK | 1 |
| 0x03 | HLZ | 1 |
| 0xFF | RECORD_UNKNOWN | 0 |
DTCSNAPSHOTIDENTIFIER
Dimensions: 5 rows × 9 columns
| UWNR | UWTEXT | UW_EINH | L/H | UWTYP | NAME | MUL | DIV | ADD |
|---|---|---|---|---|---|---|---|---|
| 0x1700 | KM_STAND | 0-n | - | 0xFFFFFF | - | 1 | 1 | 0.000000 |
| 0x1701 | ABS_ZEIT | 0-n | - | 0xFFFFFFFF | - | 1 | 1 | 0.000000 |
| 0x1702 | SAE_CODE | 0-n | - | 0xFFFFFF | - | 1 | 1 | 0.000000 |
| 0x1731 | Fehlerklasse_DTC | - | - | u char | - | 1 | 1 | 0.000000 |
| 0xFFFF | IDENTIFIER_UNKNOWN | - | - | 0xFFFFFF | - | 1 | 1 | 0.000000 |
FEHLERKLASSE
Dimensions: 5 rows × 2 columns
| NR | TEXT |
|---|---|
| 0x00 | Keine Fehlerklasse verfuegbar |
| 0x01 | Ueberpruefung bei naechstem Werkstattbesuch |
| 0x02 | Ueberpruefung bei naechstem Halt |
| 0x04 | Ueberpruefung sofort erforderlich ! |
| 0xFF | unbekannte Fehlerklasse |
DIAGMODE
Dimensions: 11 rows × 3 columns
| NR | MODE | MODE_TEXT |
|---|---|---|
| 0x00 | UNGUELTIG | DefaultMode |
| 0x01 | DEFAULT | DefaultMode |
| 0x02 | ECUPM | ECUProgrammingMode |
| 0x03 | ECUEXTDIAG | ECUExtendedDiagnosticSession |
| 0x04 | ECUSSDS | ECUSafetySystemDiagnosticSession |
| 0x40 | ECUEOL | ECUEndOfLineSession |
| 0x41 | ECUCODE | ECUCodingSession |
| 0x42 | ECUSWT | ECUSwtSession |
| 0x43 | ECUHDD | ECUHDDDownloadSession |
| 0x4F | ECUDEVELOP | ECUDevelopmentSession |
| 0xXY | -- | unbekannter Diagnose-Mode |
IARTTEXTE
Dimensions: 18 rows × 2 columns
| ARTNR | ARTTEXT |
|---|---|
| 0x00 | keine Fehlerart verfügbar |
| 0x04 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x05 | Fehler momentan vorhanden und bereits gespeichert |
| 0x08 | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x09 | Fehler momentan vorhanden und bereits gespeichert |
| 0x0C | Fehler momentan nicht vorhanden, aber bereits gespeichert |
| 0x0D | Fehler momentan vorhanden und bereits gespeichert |
| 0x44 | Fehler gespeichert |
| 0x45 | Fehler gespeichert |
| 0x48 | Fehler gespeichert |
| 0x49 | Fehler gespeichert |
| 0x4C | Fehler gespeichert |
| 0x4D | Fehler gespeichert |
| 0x10 | Testbedingungen erfüllt |
| 0x11 | Testbedingungen noch nicht erfüllt |
| 0x80 | Fehler würde kein Aufleuchten einer Warnlampe verursachen |
| 0x81 | Fehler würde das Aufleuchten einer Warnlampe verursachen |
| 0xFF | unbekannte Fehlerart |
UDS_TAB_ROE_AKTIV
Dimensions: 3 rows × 2 columns
| NR | TEXT |
|---|---|
| 0x00 | Aktive Fehlermeldung deaktiviert |
| 0x01 | Aktive Fehlermeldung aktiviert |
| 0xFF | Status der aktiven Fehlermeldung nicht feststellbar |
JOBRESULTEXTENDED
Dimensions: 1 rows × 2 columns
| SB | STATUS_TEXT |
|---|---|
| 0xXY | ERROR_UNKNOWN |
BETRIEBSMODE
Dimensions: 3 rows × 3 columns
| WERT | TEXT | BEDEUTUNG |
|---|---|---|
| 0x00 | Allgemeiner Fertigungs- und Energiesparmode | Alle Systeme aktiviert |
| 0x01 | Spezieller Energiesparmode | HSR Regelsysteme deaktiviert |
| 0xFF | ungültiger Betriebsmode | ungültig |
FORTTEXTE
Dimensions: 60 rows × 3 columns
| ORT | ORTTEXT | EREIGNIS_DTC |
|---|---|---|
| 0x022B00 | Energiesparmode aktiv | 0 |
| 0x02FF2B | DM Test Application | 0 |
| 0x480380 | Hardwarefehler Steuergerät | 0 |
| 0x480381 | Überwachung | 0 |
| 0x480382 | Fahrgestellnummervergleich | 0 |
| 0x480383 | Unterspannung Klemme 15n oder 30 (< 9 V) | 1 |
| 0x480384 | Überspannung Klemme 15n oder 30 (> 15 V) | 1 |
| 0x480385 | Motorblockade | 0 |
| 0x480386 | Codierdatenfehler | 0 |
| 0x480387 | Motorpositionssensor | 0 |
| 0x480388 | Motorspannung, Motorstrom | 0 |
| 0x480389 | Motorposition | 0 |
| 0x48038A | unbekannter Fehlerort | 0 |
| 0x48038B | Selbsthemmungsüberwachung | 0 |
| 0x48038C | Kombinierte Lage- und Drehzahlüberwachnung | 0 |
| 0x48038D | Spurstangenlagesensor | 0 |
| 0x48038E | Diversitäres Rechnen | 0 |
| 0x48038F | Flashfehler | 0 |
| 0x480390 | Betriebsystem | 0 |
| 0x480391 | Klemme 30 | 1 |
| 0x480393 | Motorposition initialisieren | 1 |
| 0x480394 | Aufstartverzögerung | 0 |
| 0x480395 | Unterspannung Klemme 15n (< 9 V) | 1 |
| 0x480396 | Unterspannung Klemme 30 (< 9 V) | 1 |
| 0x480397 | Überspannung Klemme 15n (> 15 V) | 1 |
| 0x480398 | Überspannung Klemme 30 (> 15 V) | 1 |
| 0x480399 | Elmosfehler | 0 |
| 0x48039a | Softwarefehler | 0 |
| 0x48039b | Tasküberwachungsfehler | 0 |
| 0x48039c | Endstufenübertemperatur | 0 |
| 0x48039d | Zwischenkreisfehler | 0 |
| 0x48039e | Endstufenfehler | 0 |
| 0x48039f | AD-Wandlerfehler | 0 |
| 0x4803a0 | Selbsthemmung zu gering | 0 |
| 0x4803a2 | Überlastschutz | 0 |
| 0x4803a3 | Spurstangenlagesensor | 0 |
| 0x4803a4 | Spurstangenlagesensor | 0 |
| 0x4803a5 | Entfall Freigabe Auslenkung durch ICM | 1 |
| 0x4803a6 | Auslenkung abgebrochen mit Fehler | 0 |
| 0xD3C41F | Flexray physikalischer Busfehler | 1 |
| 0xD3C420 | Flexray Controllerfehler | 0 |
| 0xD3CBFF | DM Test Network | 1 |
| 0xD3D400 | Kommunikation Zeitüberschreitung | 1 |
| 0xD3D401 | Botschaft (Sollwinkel von ICM-QL) Fehler | 1 |
| 0xD3D402 | Botschaft (Klemmen von CAS) Fehler | 1 |
| 0xD3D403 | Botschaft (Fahrgestellnummer von CAS) Fehler | 1 |
| 0xD3D404 | Botschaft (Längsbeschleunigung Schwerpunkt von ICM-QL) Fehler | 1 |
| 0xD3D405 | Botschaft (Vertikalbeschleunigung Schwerpunkt von ICM_QL) Fehler | 1 |
| 0xD3D406 | Botschaft (Ist Lenkwinkel Vorderachse von ICM-QL) Fehler | 1 |
| 0xD3D407 | Botschaft (Geschwindigkeit Fahrzeug von ICM-QL) Fehler | 1 |
| 0xD3D408 | Botschaft (Höhenstand Fahrzeug von ICM-QL) Fehler | 1 |
| 0xD3D409 | Botschaft (ZV und Klappenzustand von CAS) Fehler | 1 |
| 0xD3D40a | Botschaft (Ist Bremsmoment Summe von DSC) Fehler | 1 |
| 0xD3D40b | Botschaft (Status Stabilisierung DSC von DSC) Fehler | 1 |
| 0xD3D40c | Botschaft (Ist Drehzahl Rad von DSC) Fehler | 1 |
| 0xD3D40d | Botschaft (Radmoment Antrieb 1 von DME1) Fehler | 1 |
| 0xD3D40e | Botschaft (Ist Anzahl Geberflanken Rad von DSC) Fehler | 1 |
| 0xD3D40f | Botschaft (Drehmoment Kurbelwelle 1 von DME1) Fehler | 1 |
| 0xD3D410 | Winkelfehler ICM | 1 |
| 0xFFFFFF | unbekannter Fehlerort | 0 |
FDETAILSTRUKTUR
Dimensions: 6 rows × 2 columns
| NAME | TYP |
|---|---|
| F_UWB_ERW | ja |
| SAE_CODE | ja |
| F_HLZ | ja |
| F_SEVERITY | nein |
| F_UWB_SATZ | 2 |
| F_HLZ_VIEW | - |
FUMWELTTEXTE
Dimensions: 5 rows × 9 columns
| UWNR | UWTEXT | UW_EINH | L/H | UWTYP | NAME | MUL | DIV | ADD |
|---|---|---|---|---|---|---|---|---|
| 0x400d | Fehlercode (KFC) | 0-n | - | 0xff | TAB_KFC | - | - | - |
| 0x400a | Fehlerart (KFA) | 0-n | - | 0xff | TAB_KFA | - | - | - |
| 0x4000 | Systemstatus | 0-n | - | 0xff | TAB_STMSTATE | - | - | - |
| 0x4005 | Spannung Klemme 15n | V | - | unsigned char | - | 128 | 1000 | 0 |
| 0x4008 | Temperatur | °C | - | signed char | - | - | - | - |
IORTTEXTE
Dimensions: 186 rows × 3 columns
| ORT | ORTTEXT | EREIGNIS_DTC |
|---|---|---|
| 0x2b0000 | NVM_E_WRITE_FAILED | 0 |
| 0x2b0001 | NVM_E_READ_FAILED | 0 |
| 0x2b0002 | NVM_E_CONTROL_FAILED | 0 |
| 0x2b0003 | NVM_E_ERASE_FAILED | 0 |
| 0x2b0004 | NVM_E_READ_ALL_FAILED | 0 |
| 0x2b0005 | NVM_E_WRITE_ALL_FAILED | 0 |
| 0x2b0006 | NVM_E_WRONG_CONFIG_ID | 0 |
| 0x2b0007 | DEM_EVENT_KFC_DRIVER | 0 |
| 0x2b0008 | DEM_EVENT_ELMCSI | 0 |
| 0x2b0009 | DEM_EVENT_KFC_CODING_DATA_OUT_OF_BOUNDS_NEC | 0 |
| 0x2b000a | DEM_EVENT_KFC_CODING_DATA_OUT_OF_BOUNDS_S12X | 0 |
| 0x2b000b | DEM_EVENT_KFC_S12_AGB | 0 |
| 0x2b000c | DEM_EVENT_KFC_IPC | 0 |
| 0x2b000d | DEM_EVENT_KFC_S12_IPC | 0 |
| 0x2b000e | DEM_EVENT_KFC_RAM | 0 |
| 0x2b000f | DEM_EVENT_KFC_ROM | 0 |
| 0x2b0010 | DEM_EVENT_KFC_STM | 0 |
| 0x2b0011 | DEM_EVENT_KFC_S12_WATCHDOG | 0 |
| 0x2b0012 | DEM_EVENT_KFC_FLASH | 0 |
| 0x2b0013 | DEM_EVENT_KFC_S12_FLASH | 0 |
| 0x2b0014 | DEM_EVENT_KFC_S12_FR_REC | 1 |
| 0x2b0015 | DEM_EVENT_KFC_S12_FR_SEND | 0 |
| 0x2b0016 | DEM_EVENT_KFC_FR_SEND | 0 |
| 0x2b0017 | DEM_EVENT_KFC_OS_ERROR | 0 |
| 0x2b0018 | DEM_EVENT_KFC_WDG_1MS | 0 |
| 0x2b0019 | DEM_EVENT_KFC_WDG_INT | 0 |
| 0x2b001a | DEM_EVENT_KFC_D3PDH_ILS | 0 |
| 0x2b001b | DEM_EVENT_KFC_PHASE_UZK_SC | 0 |
| 0x2b001c | DEM_EVENT_KFC_PHASE_GND_SC | 0 |
| 0x2b001d | DEM_EVENT_KFC_LSSW_U_OC | 0 |
| 0x2b001e | DEM_EVENT_KFC_LSSW_V_OC | 0 |
| 0x2b001f | DEM_EVENT_KFC_LSSW_W_OC | 0 |
| 0x2b0020 | DEM_EVENT_KFC_HSSW_U_OC | 0 |
| 0x2b0021 | DEM_EVENT_KFC_HSSW_V_OC | 0 |
| 0x2b0022 | DEM_EVENT_KFC_HSSW_W_OC | 0 |
| 0x2b0023 | DEM_EVENT_KFC_PWM3PH_INIT | 0 |
| 0x2b0024 | DEM_EVENT_KFC_ELMOSH_BS_UNDERVOLTAGE | 0 |
| 0x2b0025 | DEM_EVENT_KFC_MOTOR_OC | 0 |
| 0x2b0026 | DEM_EVENT_KFC_TOFF | 0 |
| 0x2b0027 | DEM_EVENT_KFC_ANALOG_SIGNALS_NOT_VALID | 0 |
| 0x2b0028 | DEM_EVENT_KFC_OFFSET_CALIB_FAILED | 0 |
| 0x2b0029 | DEM_EVENT_KFC_ELMOSH_S_E_LINK | 0 |
| 0x2b002a | DEM_EVENT_KFC_ELMOSH_S_E_SPIBUF_OVL | 0 |
| 0x2b002b | DEM_EVENT_KFC_ELMOSH_S_E_TIMEOUT | 0 |
| 0x2b002c | DEM_EVENT_KFC_ELMOSH_UNDERVOLTAGE | 0 |
| 0x2b002d | DEM_EVENT_KFC_ELMOSH_OVERCURRENT | 0 |
| 0x2b002e | DEM_EVENT_KFC_ELMOSH_FAULTPIN_LOW | 0 |
| 0x2b002f | DEM_EVENTKFC_5V0A_UNDERVOLTAGE | 0 |
| 0x2b0030 | DEM_EVENT_PRG_SW | 0 |
| 0x2b0031 | DEM_EVENT_KCF_CCU | 0 |
| 0x2b0032 | DEM_EVENT_KCF_SMVOLT | 0 |
| 0x2b0033 | DEM_EVENT_KFC_PWR_OUT | 0 |
| 0x2b0035 | DEM_EVENT_KFC_SMCURR | 0 |
| 0x2b0036 | DEM_EVENT_KFC_SMPOS | 0 |
| 0x2b0039 | DEM_EVENT_KFC_ADC | 0 |
| 0x2b003a | DEM_EVENT_KFC_SMCOM | 0 |
| 0x2b003b | DEM_EVENT_KFC_SELFLOCK | 0 |
| 0x2b003c | DEM_EVENT_KFC_ACT_KLD | 0 |
| 0x2b003d | DEM_EVENT_KFC_WRONG_KFC_FROM_ZFLS | 0 |
| 0x2b003e | DEM_EVENT_KFC_ACT_BLOCK | 0 |
| 0x2b003f | DEM_EVENT_KFC_WACKEL | 1 |
| 0x2b0040 | DEM_EVENT_KFC_SENS_SLGS | 0 |
| 0x2b0041 | DEM_EVENT_KFC_TAR_STEA_MSG | 1 |
| 0x2b0042 | DEM_EVENT_KFC_DISCHARGE | 0 |
| 0x2b0043 | DEM_EVENT_KFC_S12_OS | 0 |
| 0x2b0044 | DEM_EVENT_KFC_AGB | 0 |
| 0x2b0045 | DEM_EVENT_KFC_PWR_KL30 | 1 |
| 0x2b0046 | DEM_EVENT_KFC_S12_STM_ERROR | 0 |
| 0x2b0047 | DEM_EVENT_KFC_S12_TSACTRL | 0 |
| 0x2b0048 | DEM_EVENT_KFC_TEMP | 0 |
| 0x2b0049 | DEM_EVENT_KFC_TAR_STEA_TIMEOUT | 1 |
| 0x2b004a | DEM_EVENT_KFC_TSA_BOUND | 0 |
| 0x2b004b | DEM_EVENT_KFC_HSR_ERROR | 0 |
| 0x2b004c | DEM_EVENT_KFC_KL30_UNDERVOLTAGE | 1 |
| 0x2b004d | DEM_EVENT_KFC_KL30_OVERVOLTAGE | 1 |
| 0x2b004e | DEM_EVENT_KFC_KL15_UNDERVOLTAGE | 1 |
| 0x2b004f | DEM_EVENT_KFC_KL15_OVERVOLTAGE | 1 |
| 0x2b0050 | DEM_EVENT_KFC_SSW_MOSFET_OC | 0 |
| 0x2b0051 | DEM_EVENT_KFC_PCHARGE_OR_SSW_MOSFET_SC | 0 |
| 0x2b0052 | DEM_EVENT_KFC_PCHARGE_OC_OR_POWERSTAGE_SC | 0 |
| 0x2b0053 | DEM_EVENT_KFC_SAFETY_SWITCH_2_SC | 0 |
| 0x2b0054 | DEM_EVENT_KFC_SAFETY_SWITCH_1_SC | 0 |
| 0x2b0055 | CODING_EVENT_SIGNATURE_ERROR | 0 |
| 0x2b0056 | CODING_EVENT_WRONG_VEHICLE | 1 |
| 0x2b0057 | CODING_EVENT_TRANSACTION_FAILED | 0 |
| 0x2b0058 | CODING_EVENT_INVALID_DATA | 1 |
| 0x2b0059 | DEM_EVENT_KFC_VINCOMP | 0 |
| 0x2b005a | DEM_EVENT_KFC_MAXAKTDIFF | 0 |
| 0x2b005b | DEM_EVENT_KFC_3V3A_2_UNDERVOLTAGE | 0 |
| 0x2b005c | DEM_EVENT_KFC_VERS_SLS | 0 |
| 0x2b005d | DEM_EVENT_KFC_VERS_MLS | 0 |
| 0x2b005e | DEM_EVENT_KFC_MOTORPHASE_OC | 0 |
| 0x2b005f | DEM_EVENT_KFC_NOT_CONFIGURED_IN_TRESOS | 0 |
| 0x2b0060 | DEM_EVENT_KFC_FR_FLX | 1 |
| 0x2b0061 | DEM_EVENT_KFC_FR_CC | 0 |
| 0x2b0062 | DEM_EVENT_KFC_SET_MLW_INVALID | 1 |
| 0x2b0063 | DEM_EVENT_KFC_REQ_RESTART | 1 |
| 0x2b0064 | DEM_EVENT_KFC_S12_SMCOM | 0 |
| 0x2b0069 | DEM_EVENT_KFC_WAIT_FOR_RLW_SET | 0 |
| 0x2b006a | DEM_EVENT_KFC_FR_KLEMMEN | 1 |
| 0x2b006b | DEM_EVENT_KFC_TAR_STEA_MAXTIMEOUTS | 1 |
| 0x2b006c | DEM_EVENT_KFC_EEPROM | 0 |
| 0x2b006d | DEM_EVENT_KFC_ELMOS_ON | 0 |
| 0x2b006e | DM_Queue_DELETED | 0 |
| 0x2b006f | DM_Queue_FULL | 0 |
| 0x2b0070 | DEM_EVENT_ZFLS_UNDERVOLTAGE | 1 |
| 0x2b0071 | DEM_EVENT_KFC_VINTIMEOUT | 1 |
| 0x2b0072 | DEM_EVENT_KFC_ZWK | 0 |
| 0x2b0073 | DEM_EVENT_KFC_SSW_OFF | 0 |
| 0x2b0075 | DEM_EVENT_KFC_PPROT | 0 |
| 0x2b0076 | DEM_EVENT_KFC_AGB_LIMIT | 0 |
| 0x2b007c | DEM_EVENT_KFC_SW_WARNING | 0 |
| 0x2b007d | DEM_EVENT_KFC_SKEIS_FLANKENZYKLUS | 1 |
| 0x2b007e | DEM_EVENT_KFC_SKEIS_FLANKENZAHL | 1 |
| 0x2b007f | DEM_EVENT_KFC_SKEIS_RDZ_ZYKLUS | 1 |
| 0x2b0080 | DEM_EVENT_KFC_SKEIS_HS | 1 |
| 0x2b0081 | DEM_EVENT_KFC_SKEIS_HS_KODIERUNG | 0 |
| 0x2b0082 | DEM_EVENT_FRA_ACLNX_MASSCNTR_ACLNY_MASSCNTR | 1 |
| 0x2b0083 | DEM_EVENT_FRA_ACLNZ_COG_VYAW_VEH | 1 |
| 0x2b0084 | DEM_EVENT_FRA_AVL_STEA_FTAX | 1 |
| 0x2b0085 | DEM_EVENT_FRA_V_VEH | 1 |
| 0x2b0086 | DEM_EVENT_FRA_HGLV_VEH | 1 |
| 0x2b0087 | DEM_EVENT_FRA_STAT_ZV_KLAPPEN | 1 |
| 0x2b0088 | DEM_EVENT_FRA_AVL_BRTORQ_SUM_ST_PRMSN_IBRK | 1 |
| 0x2b0089 | DEM_EVENT_FRA_ST_STAB_DSC | 1 |
| 0x2b008a | DEM_EVENT_FRA_AVL_RPM_WHL | 1 |
| 0x2b008b | DEM_EVENT_FRA_WMOM_DRV_1 | 1 |
| 0x2b008c | DEM_EVENT_FRA_AVL_QUAN_EES_WHL | 1 |
| 0x2b008d | DEM_EVENT_FRA_TORQ_CRSH_1_ANG_ACPD | 1 |
| 0x2b008e | DEM_EVENT_KFC_KLD_MINI | 0 |
| 0x2b008f | DEM_EVENT_KFC_US | 0 |
| 0x2b0090 | DEM_EVENT_KFC_ELMCSI | 0 |
| 0x2b0091 | DEM_EVENT_KFC_S12X_TSA_PLAUS | 0 |
| 0x2b0092 | DEM_EVENT_KFC_PWR_OUT_INIT | 0 |
| 0x2b0093 | DEM_EVENT_KFC_TSENSOR | 0 |
| 0x2b0094 | DEM_EVENT_KFC_INFO_ZWK_UNDERVOLTAGE | 1 |
| 0x2b0095 | DEM_EVENT_KFC_INFO_ZWK_PL_UNDERVOLTAGE | 1 |
| 0x2b0096 | DEM_EVENT_KFC_INFO_ZWK_OVERVOLTAGE | 1 |
| 0x2b0097 | DEM_EVENT_KFC_INFO_ZWK_PL_OVERVOLTAGE | 1 |
| 0x2b0098 | DEM_EVENT_KFC_INFO_ZWK_LONG_PL | 0 |
| 0x2b0099 | DEM_EVENT_KFC_INFO_FRPHYS | 0 |
| 0x2b009a | DEM_EVENT_KFC_FRPHYS | 0 |
| 0x2b009b | DEM_EVENT_KFC_INFO_FRPHYS_STATUS_UP | 0 |
| 0x2b009c | DEM_EVENT_KFC_FRPHYS_SPI | 0 |
| 0x2b009d | DEM_EVENT_KFC_FRPHYS_INIT | 0 |
| 0x2b009e | DEM_EVENT_KFC_INFO_FRPHYS_REINIT | 0 |
| 0x2b009f | DEM_EVENT_KFC_NO_SERVICE_ICM | 1 |
| 0x2b00a0 | DEM_EVENT_KFC_STM_LOW_VLTG4DRIVE | 0 |
| 0x2b00a1 | DEM_EVENT_KFC_SKE_SCHED_DATA | 1 |
| 0x2b0100 | DEM_EVENT_KFC_NO_SERVICE_KL | 1 |
| 0x2b0101 | DEM_EVENT_KFC_SLGS_NOSIGNAL_PWM | 0 |
| 0x2b0102 | DEM_EVENT_KFC_SLGS_NOSIGNAL_PWMK | 0 |
| 0x2b0103 | DEM_EVENT_KFC_SLGS_NOSIGNAL_PWM_TIMEOUT | 0 |
| 0x2b0104 | DEM_EVENT_KFC_SLGS_NOSIGNAL_PWMK_TIMEOUT | 0 |
| 0x2b0105 | DEM_EVENT_KFC_SLGS_STARTUP_PWM | 0 |
| 0x2b0106 | DEM_EVENT_KFC_SLGS_STARTUP_PWM_TIMEOUT | 0 |
| 0x2b0107 | DEM_EVENT_KFC_SLGS_STARTUP_PWMK_TIMEOUT | 0 |
| 0x2b0108 | DEM_EVENT_KFC_SLGS_FREQ | 0 |
| 0x2b0109 | DEM_EVENT_KFC_SLGS_DC | 0 |
| 0x2b010a | DEM_EVENT_KFC_SLGS_DCM_OVERFLOW | 0 |
| 0x2b010b | DEM_EVENT_KFC_SLGS_STARTUP_PWMK | 0 |
| 0x2b010c | DEM_EVENT_KFC_S12_AGB_TSA | 0 |
| 0x2b010d | DEM_EVENT_KFC_DRLS | 0 |
| 0x2b010e | DEM_EVENT_KFC_ACTIVE_DIAG | 0 |
| 0x2b010f | DEM_EVENT_KFC_S12_RLS_COMPARE | 0 |
| 0x2b0110 | DEM_EVENT_KFC_KLD | 0 |
| 0x2b0111 | DEM_EVENT_KFC_S12_AGB_LOCK | 0 |
| 0x2b0112 | DEM_EVENT_KFC_VERS_SLS_KL15 | 0 |
| 0x2b0113 | DEM_EVENT_KFC_PRG_SW_ACTSTM | 0 |
| 0x2b0114 | DEM_EVENT_KFC_TORQUE | 0 |
| 0x2b0115 | DEM_EVENT_KFC_SKE_IS_SIG_CHECK | 0 |
| 0x2b0116 | DEM_EVENT_KFC_SKE_IS_SCHED_DATA | 0 |
| 0x2b0117 | DEM_EVENT_KFC_SKE_IS_SIG_ALIVE | 0 |
| 0x2b0118 | DEM_EVENT_KFC_SKE_IS_FKT_ERR | 0 |
| 0x2b0119 | DEM_EVENT_KFC_S12_PRG_SW_ACTSTM | 0 |
| 0x2b011a | DEM_EVENT_KFC_SLGS_INFO_EVTCNT | 0 |
| 0x2b011b | DEM_EVENT_KFC_SLGS_INFO_DCM | 0 |
| 0x2b011c | DEM_EVENT_KFC_SLGS_INFO_CAP | 0 |
| 0x2b011d | DEM_EVENT_KFC_SLGS_INFO_SUPTIME | 0 |
| 0x2b011e | DEM_EVENT_KFC_SLGS_INFO_TIME | 0 |
| 0x2b011f | DEM_EVENT_KFC_SLGS_INFO_LASTPWM | 0 |
| 0x2b0120 | DEM_EVENT_KFC_SLGS_INFO_LASTPWMK | 0 |
| 0x2b0121 | DEM_EVENT_KFC_BIST_INFO_RESTART | 0 |
| 0x2b7000 | VSM_EVENT_VEHICLESTATE | 1 |
| 0x2b8000 | DM_EVENT_ZEITBOTSCHAFTTIMEOUT | 1 |
| 0xFFFFFF | Unbekannter Fehlerort | 0 |
IDETAILSTRUKTUR
Dimensions: 4 rows × 2 columns
| NAME | TYP |
|---|---|
| F_UWB_ERW | ja |
| SAE_CODE | ja |
| F_HLZ | ja |
| F_SEVERITY | nein |
IUMWELTTEXTE
Dimensions: 21 rows × 9 columns
| UWNR | UWTEXT | UW_EINH | L/H | UWTYP | NAME | MUL | DIV | ADD |
|---|---|---|---|---|---|---|---|---|
| 0x400a | Fehlerart (KFA) | 0-n | - | 0xff | TAB_KFA | - | - | - |
| 0x4000 | Systemstatus | 0-n | - | 0xff | TAB_STMSTATE | - | - | - |
| 0x4003 | Systemstatus Counter | - | - | unsigned char | - | - | - | - |
| 0x400c | Z-Status | - | - | unsigned char | - | - | - | - |
| 0x4004 | Ersatzmassnahme | - | - | unsigned char | - | - | - | - |
| 0x4001 | Sollwinkel | ° | high | signed int | - | 1 | 1000 | 0 |
| 0x4002 | Istwinkel | ° | high | signed int | - | 1 | 1000 | 0 |
| 0x4005 | Spannung Klemme 15n | V | - | unsigned char | - | 128 | 1000 | 0 |
| 0x4006 | Spannung Klemme 30 | V | - | unsigned char | - | 128 | 1000 | 0 |
| 0x4007 | Spannung Zwischenkreis | V | - | unsigned char | - | 128 | 1000 | 0 |
| 0x4008 | Temperatur | °C | - | signed char | - | - | - | - |
| 0x4009 | Uptime | ms | high | signed long | - | - | - | - |
| 0x400b | Local Condition | hex | - | signed long | - | - | - | - |
| 0x400e | Sperrenzustand | - | - | unsigned char | - | - | - | - |
| 0x400f | Sollwertqualifier ICM | - | - | unsigned char | - | - | - | - |
| 0x4010 | Klemmenstatus | - | - | unsigned char | - | - | - | - |
| 0x400d | Fehlercode (KFC) | 0-n | - | 0xff | TAB_KFC | - | - | - |
| 0x4011 | DET Sequenznummer | - | - | unsigned char | - | - | - | - |
| 0x4012 | Anzahl MLW-Verlust | - | - | unsigned char | - | - | - | - |
| 0x4013 | Anzahl Aktive Diagnose | - | - | unsigned char | - | - | - | - |
| 0x4014 | Filterung | - | - | unsigned char | - | - | - | - |
SG_FUNKTIONEN
Dimensions: 28 rows × 16 columns
| ARG | ID | RESULTNAME | INFO | EINHEIT | LABEL | L/H | DATENTYP | NAME | MUL | DIV | ADD | SG_ADR | SERVICE | ARG_TABELLE | RES_TABELLE |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| AUSLENKUNGSTEST_HINTERACHSE | 0xAB92 | - | Führt die Ansteuerung der HSR nach einem festen Schema aus ( Steller in 0 Pos --> linker Anschlag --> rechter Anschlag --> 0 Pos | - | - | - | - | - | - | - | - | - | 31 | - | RES_0xAB92 |
| AUSLENKUNG_HINTERACHSE | 0xAB94 | - | Fährt den gewünschten Lenkwinkel (LENKWINKEL_WERT) an der HA an. | - | - | - | - | - | - | - | - | - | 31 | ARG_0xAB94 | RES_0xAB94 |
| BUS_IN_CAS_INFO | 0xDBA8 | - | Auslesen der vom CAS gesendeten Fahrgestellnummer | - | - | - | - | - | - | - | - | - | 22 | - | RES_0xDBA8 |
| ERSATZMASSNAHME | 0xDBAD | - | Aktuelle Ersatzmassnahme. Degradation im Fehlerfall. | - | - | - | - | - | - | - | - | - | 22 | - | RES_0xDBAD |
| FLEXRAY_SIGNALE | 0xDBAB | - | Signale vom FlexRay | - | - | - | - | - | - | - | - | - | 22 | - | RES_0xDBAB |
| HSR_ALIVECOUNTER | 0xDB90 | - | Alive Counter zur Kontrolle der Kommunikation HSR | - | - | - | - | - | - | - | - | - | 22 | - | RES_0xDB90 |
| HSR_MOTORSPANNUNGEN | 0xDBBA | - | Motorspannung des HSR Motors. Ausgabe der Spannung für alle 3 Phasen | - | - | - | - | - | - | - | - | - | 22 | - | RES_0xDBBA |
| HSR_MOTORSTROEME | 0xDBB6 | - | Motorstrom des HSR Motors. Ausgabe des Stroms für alle 3 Phasen | - | - | - | - | - | - | - | - | - | 22 | - | RES_0xDBB6 |
| HSR_SG_TEMPERATUR | 0xDB89 | STAT_ZWK_TEMPERATUR_WERT | HSR SG Temperatur | °C | - | - | int | - | - | - | - | - | 22 | - | - |
| MOTORLAGEWINKEL_HINTERACHSE | 0xDBAF | - | Motorlagewinkel des HSR Motor. | - | - | - | - | - | - | - | - | - | 22 | - | RES_0xDBAF |
| MOTORLAGEWINKEL_INITIALISIERUNG | 0xDB9C | STAT_GUELTIGKEIT_MLW_NR | Information ob HSR Motorlagewinkel bereits initialisiert wurde. | 0-n | - | - | unsigned char | TAB_MLWSTATE | - | - | - | - | 22 | - | - |
| MOTORLAGEWINKEL_RUECKSETZEN | 0xAB90 | - | Motorlagewinkel wird ungültig gesetzt | - | - | - | - | - | - | - | - | - | 31 | - | - |
| MOTORLAGEWINKEL_SETZEN | 0xAB8F | - | Motorlagewinkel wird gültig gesetzt | - | - | - | - | - | - | - | - | - | 31 | - | - |
| OPERATINGSYSTEM_HSR | 0xDB88 | - | Daten vom HSR OS (Betriebssystem) | - | - | - | - | - | - | - | - | - | 22 | - | RES_0xDB88 |
| SENSORDIFFERENZ | 0xDBBB | - | Sensorplausibilisierung. Differenz zwischen den Werten des RLS und SLS. | - | - | - | - | - | - | - | - | - | 22 | - | RES_0xDBBB |
| SPANNUNG_KLEMME_15N_WERT | 0xDAD2 | STAT_SPANNUNG_KLEMME_15N_WERT | Job zum Auslesen der Klemmensteuerung am Steuergerät. | V | - | - | int | - | - | 10 | - | - | 22 | - | - |
| SPANNUNG_KLEMME_30_WERT | 0xDAD8 | STAT_SPANNUNG_KLEMME_30_WERT | Job zum Auslesen der Klemmensteuerung am Steuergerät. | V | - | - | int | - | - | 10 | - | - | 22 | - | - |
| SPURSTANGENLAGESENSOR | 0xDBB0 | - | Winkel vom Spurstangenlagesensor | - | - | - | - | - | - | - | - | - | 22 | - | RES_0xDBB0 |
| STATUS_ICM | 0xDBAE | - | ICM-QL Signale auf A-FlexRay | - | - | - | - | - | - | - | - | - | 22 | - | RES_0xDBAE |
| STATUS_KLEMME_15N_EIN | 0xDAFF | STAT_STATUS_KLEMME_15N_EIN | Job liefert den Status der Klemme(n) im Steuergerät: 0=AUS; 1=EIN | 0/1 | - | - | int | - | - | - | - | - | 22 | - | - |
| STATUS_KLEMME_30_EIN | 0xDB05 | STAT_STATUS_KLEMME_30_EIN | Job liefert den Status der Klemme(n) im Steuergerät: 0=AUS; 1=EIN | 0/1 | - | - | int | - | - | - | - | - | 22 | - | - |
| VERSORGUNG | 0xDBAA | - | Versorgungsspannungen des Steuergeräts | - | - | - | - | - | - | - | - | - | 22 | - | RES_0xDBAA |
| CODIERDATEN_LESEN | 0x4100 | - | Auslesen aller Codierparameter | - | - | - | - | - | - | - | - | - | 22 | - | RES_0x4100 |
| SKE_RINGBUFFER_LESEN | 0x4101 | - | Auslesen des SKE Ringpuffers | - | - | - | - | - | - | - | - | - | 22 | - | RES_0x4101 |
| SKE_RINGBUFFER_LOESCHEN | 0x4102 | - | Loeschen des SKE Ringbuffers | - | - | - | - | - | - | - | - | - | 31 | - | - |
| EEE_EXECUTE | 0x4103 | - | Ausführen von Kommandos in NEC EEELib | - | - | - | - | - | - | - | - | - | 31 | ARG_0x4103 | RES_0x4103 |
| SKE_FESTUS_LESEN | 0x4104 | - | Auslesen von SKE Festus Variablen | - | - | - | - | - | - | - | - | - | 22 | - | RES_0x4104 |
| CODIERDATEN_LOESCHEN | 0x4105 | - | Löschen der Codierdaten. | - | - | - | - | - | - | - | - | - | 31 | - | - |
RES_0XDBAB
Dimensions: 6 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_MESSAGE_KLEMMEN_NR | 0-n | - | unsigned char | - | TAB_PDUSTATE | - | - | - | Qualifier für die KLEMMEN Nachricht |
| STAT_MESSAGE_KILOMETERSTAND_NR | 0-n | - | unsigned char | - | TAB_PDUSTATE | - | - | - | Qualifier für Kilometerstand |
| STAT_MESSAGE_TAR_STEA_ACT_NR | 0-n | - | unsigned char | - | TAB_PDUSTATE | - | - | - | Qualifier für die TAR_STEA_ACT Nachricht (Sollwertvorgabe - Winkel - von ICMQL) |
| STAT_MESSAGE_RELATIVZEIT_NR | 0-n | - | unsigned char | - | TAB_PDUSTATE | - | - | - | Qualifier : Zeit ab Zündung EIN (Kl.50) |
| STAT_MESSAGE_FAHRGESTELL_NR | 0-n | - | unsigned char | - | TAB_PDUSTATE | - | - | - | Qualifier für die VIN Nachricht |
| STAT_MESSAGE_FZZSTD_NR | 0-n | - | unsigned char | - | TAB_PDUSTATE | - | - | - | Qualifier für die Nachricht Fahrzeugzustand |
RES_0XDBB0
Dimensions: 3 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_SLS_ISTWERT_CPU1_WERT | Grad | - | long | - | - | - | 1000 | - | Die Position laut Spurstangelagesensor |
| STAT_SLS_ISTWERT_GUELTIGKEIT_CPU1_NR | 0-n | - | unsigned char | - | TAB_MLWSTATE | - | - | - | Die Gueltigkeit der position laut Spurstangelagesensor |
| STAT_SLS_PWM_FREQUENZ_WERT | Hz | - | unsigned int | - | - | - | - | - | Die PWM Frequenz des Spurstangenlagesensors |
RES_0XDBBB
Dimensions: 2 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_SENSORDIFFERENZ_WERT | Grad | - | long | - | - | - | 1000 | - | Differenz zwischen den Werten von SLS unnd RLS, gemessen umgerechnet auf die position des Rotors. |
| STAT_GUELTIGKEIT_SENSORDIFFERENZ_NR | 0-n | - | unsigned char | - | TAB_MLWSTATE | - | - | - | Gueltigkeit der gebildeten Differenz |
RES_0XDB88
Dimensions: 3 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_SYSTEMZUSTAND_CPU1_NR | 0-n | - | unsigned char | - | TAB_GSTMSTATE | - | - | - | Zeigt den Systemzustand der CPU 1. |
| STAT_SYSTEMZUSTAND_CPU2_NR | 0-n | - | unsigned char | - | TAB_GSTMSTATE | - | - | - | Zeigt den Systemzustand der CPU 2. |
| STAT_SYSTEMZUSTAND_SOLL_CPU1_NR | 0-n | - | unsigned char | - | TAB_GSTMSTATE | - | - | - | Zeigt den auf der CPU 2 berechneten Soll-Systemzustand der CPU 1. |
RES_0XDBA8
Dimensions: 2 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_CAS_FAHRGESTELLNUMMER_WERT | - | - | string[7] | - | - | - | - | - | Empfangene Fahrgestellnummer |
| STAT_GUELTIGKEIT_CAS_FAHRGESTELLNR_NR | 0-n | - | unsigned char | - | TAB_PDUSTATE | - | - | - | Gueltigkeit der empfangenen Fahrgestellnummer |
RES_0XDBAD
Dimensions: 8 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_ERSATZMASSNAHME_NR | 0-n | - | unsigned char | - | TAB_STMCM | - | - | - | Aktuelle Ersatzmassnahme. Degradationszustand in Fehlerfall |
| STAT_OUTOFF | 0/1 | - | unsigned char | - | - | - | - | - | Massnahme Abschaltung Endstufe Motor, 0: Nicht abschalten, 1: Abschalten |
| STAT_DONOTDISC | 0/1 | - | unsigned char | - | - | - | - | - | Massnahme Entladung der Kondensatoren, 0: Entladen, 1: Nicht entladen |
| STAT_ROTINVALID | 0/1 | - | unsigned char | - | - | - | - | - | Massnahme Motorlagewinkel ungültig schreiben, 0: Nicht verändern, 1: Ungültig setzen |
| STAT_NUTSUCHEN | 0/1 | - | unsigned char | - | - | - | - | - | Massnahme Nutsuche Sperre, 0: Nicht durchführen, 1: Nut suchen |
| STAT_DRLSOFF | 0/1 | - | unsigned char | - | - | - | - | - | Massnahme DRLS abschalten, 0: nichts ändern, 1: DRLS abschalten |
| STAT_RESTART | 0/1 | - | unsigned char | - | - | - | - | - | Massnahme Neustart, 0: kein Neustart, 1: Neustart durtchführen |
| STAT_REQMLWINVALID | 0/1 | - | unsigned char | - | - | - | - | - | Das Ungültigsetzen des MLW (z.B. mit einem Diag-Job), 0: wird nicht verlangt 1: wird verlangt |
ARG_0XAB94
Dimensions: 1 rows × 15 columns
| ARG | STR | STPR | RRR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LENKWINKEL | + | - | - | ° | - | long | - | - | 1000 | - | - | - | - | Fährt den gewünschten Lenkwinkel (LENKWINKEL) an der Hinterachse. |
RES_0XAB92
Dimensions: 6 rows × 13 columns
| RESULTNAME | STR | STPR | RRR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| STAT_ICM_FREIGABE | - | - | + | 0/1 | - | unsigned char | - | - | - | - | - | Gibt an ob die Freigabe seitens ICM-QL besteht: 0=Nein; 1=Ja |
| STAT_SG_FREIGABE | - | - | + | 0/1 | - | unsigned char | - | - | - | - | - | Gibt an ob die Freigabe seitens SG besteht: 0=Nein; 1=Ja |
| STAT_AUSLENKUNG_MOEGLICH | - | - | + | 0/1 | - | unsigned char | - | - | - | - | - | Gibt an ob der Auslenkungstest ausgefuehrt werden kann: 0=Nein; 1=Ja |
| STAT_AUSLENKUNG_AKTIV | - | - | + | 0/1 | - | unsigned char | - | - | - | - | - | Gibt an ob die Auslenkung momentan aktiv ist: 0=Nein; 1=Ja |
| STAT_SOLLMOMENT_WERT | - | - | + | % | - | signed int | - | - | - | - | - | Gibt das aktuelle Sollmoment an |
| STAT_LETZTE_AUSLENKUNG | - | - | + | 0-n | - | unsigned char | - | TAB_ADSTATE | - | - | - | Zeigt an ob der letzte Auslenkungstest erfolgreich ausgeführt wurde |
RES_0XAB94
Dimensions: 6 rows × 13 columns
| RESULTNAME | STR | STPR | RRR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| STAT_ICM_FREIGABE | - | - | + | 0/1 | - | unsigned char | - | - | - | - | - | Gibt an ob die Freigabe seitens ICM-QL besteht: 0=Nein; 1=Ja |
| STAT_SG_FREIGABE | - | - | + | 0/1 | - | unsigned char | - | - | - | - | - | Gibt an ob die Freigabe seitens SG besteht: 0=Nein; 1=Ja |
| STAT_AUSLENKUNG_MOEGLICH | - | - | + | 0/1 | - | unsigned char | - | - | - | - | - | Gibt an ob der Auslenkungstest ausgefuehrt werden kann: 0=Nein; 1=Ja |
| STAT_AUSLENKUNG_AKTIV | - | - | + | 0/1 | - | unsigned char | - | - | - | - | - | Gibt an ob die Auslenkung momentan aktiv ist: 0=Nein; 1=Ja |
| STAT_SOLLMOMENT_WERT | - | - | + | % | - | signed int | - | - | - | - | - | Gibt das aktuelle Sollmoment an |
| STAT_LETZTE_AUSLENKUNG | - | - | + | 0-n | - | unsigned char | - | TAB_ADSTATE | - | - | - | Zeigt an ob der letzte Auslenkungstest erfolgreich ausgeführt wurde |
RES_0XDBAE
Dimensions: 4 rows × 13 columns
| RESULTNAME | STR | STPR | RRR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| STAT_ICM_ALIVECOUNTER_WERT | - | - | - | - | - | unsigned char | - | - | - | - | - | Aktueller Alivecounter ICM-QL auf BUS (Empfänger ASA, DSC). Bei Alive ändert sich dieser Wert. |
| STAT_ICM_SOLL_MLW_WERT | - | - | - | - | - | unsigned int | - | - | - | - | - | Aktueller HSR Sollwinkel ohne Einheit (Rohformat auf BUS) |
| STAT_ICM_SOLL_MLW_QUAL_NR | - | - | - | 0-n | - | unsigned char | - | TAB_QUTARSTEA | - | - | - | Sollwinkel-Qualifier von ICM-QL |
| STAT_ICM_STAT_NR | - | - | - | 0-n | - | unsigned char | - | TAB_STECUICM | - | - | - | Service Qualifier von ICM-QL |
RES_0XDBBA
Dimensions: 3 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_PHASENSPANNUNG_U_WERT | V | - | long | - | - | - | 1000 | - | Spannung der Phase U am Stator des Stellmotors |
| STAT_PHASENSPANNUNG_V_WERT | V | - | long | - | - | - | 1000 | - | Spannung der Phase V am Stator des Stellmotors |
| STAT_PHASENSPANNUNG_W_WERT | V | - | long | - | - | - | 1000 | - | Spannung der Phase W am Stator des Stellmotors |
RES_0XDB90
Dimensions: 3 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_SG_ALIVECOUNTER_WERT | - | - | unsigned char | - | - | - | - | - | Aktueller Alivecounter HSR auf BUS (Empfänger ICMQL, DSC) |
| STAT_SPI_ALIVECOUNTER_WERT | - | - | unsigned char | - | - | - | - | - | Aktueller Alivecounter HSR CPU1 und 2 auf SPI (Empfang zwischen CPU1 und 2) |
| STAT_ICM_ALIVECOUNTER_WERT | - | - | unsigned char | - | - | - | - | - | Aktueller Alivecounter ICM auf BUS (Empfänger HSR, DSC) |
RES_0XDBB6
Dimensions: 3 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_PHASENSTROM_U_WERT | A | - | long | - | - | - | 1000 | - | Phasenstrom der Phase U am Stator des Stellmotors |
| STAT_PHASENSTROM_V_WERT | A | - | long | - | - | - | 1000 | - | Phasenstrom der Phase V am Stator des Stellmotors |
| STAT_PHASENSTROM_W_WERT | A | - | long | - | - | - | 1000 | - | Phasenstrom der Phase W am Stator des Stellmotors |
RES_0XDBAA
Dimensions: 2 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_SPANNUNG_ZWISCHENKREIS_WERT | V | - | long | - | - | - | 1000 | - | Zwischenkreisspannung des Steuergerätes |
| STAT_SPANNUNGSUEBERWACHUNG_NR | 0-n | - | unsigned char | - | TAB_VLTGSTATE | - | - | - | Zustandsüberwachung der Spannungsversorgung: OK = 0, Unterspannung = 1, Überspannung = 2 |
RES_0XDBAF
Dimensions: 9 rows × 13 columns
| RESULTNAME | STR | STPR | RRR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| STAT_MLW_ISTWERT_CPU1_WERT | - | - | - | Grad | - | signed long | - | - | - | 1000 | - | Motorlagewinkel Istwert in Grad von CPU1 |
| STAT_MLW_ISTWERT_GUELTIGKEIT_CPU1_NR | - | - | - | 0-n | - | unsigned char | - | TAB_MLWSTATE | - | - | - | Qualifier für den Istwert CPU1 |
| STAT_MLW_ISTWERT_CPU2_WERT | - | - | - | Grad | - | signed long | - | - | - | 1000 | - | Motorlagewinkel Istwert in Grad, von CPU2 |
| STAT_MLW_ISTWERT_GUELTIGKEIT_CPU2_NR | - | - | - | 0-n | - | unsigned char | - | TAB_MLWSTATE | - | - | - | Qualifier für den Istwert CPU2 |
| STAT_MLW_SOLLWERT_CPU2_WERT | - | - | - | Grad | - | signed long | - | - | - | 1000 | - | Motorlagewinkel Sollwert in Grad, von CPU2 |
| STAT_MLW_SOLLWERT_CPU1_WERT | - | - | - | Grad | - | signed long | - | - | - | 1000 | - | Motorlagewinkel Sollwert in Grad, von CPU1 |
| STAT_MLW_OFFSET_WERT | - | - | - | Grad | - | signed long | - | - | - | - | - | Gespeicherter Motorlagewinkel Offset in Sensorgrad |
| STAT_MLW_RUNDENZAEHLER_WERT | - | - | - | - | - | signed long | - | - | - | - | - | Multiturnwert des Motors (Zähler für vollständige Umdrehung des Motors) |
| STAT_MLW_SELBSTINITIALISIERUNGSZAEHLER_WERT | - | - | - | - | - | signed long | - | - | - | - | - | Zähler für verlorene Motorlagwinkel (gültig--> ungültig) |
TAB_STMSTATE
Dimensions: 41 rows × 3 columns
| WERT | UWTEXT | TEXT |
|---|---|---|
| 0 | S_INIT_STARTUP | S_INIT_STARTUP |
| 1 | S_INIT_GOING_PRE_INIT | S_INIT_GOING_PRE_INIT |
| 2 | S_INIT_PRE_INIT | S_INIT_PRE_INIT |
| 3 | S_INIT_GOING_INIT | S_INIT_GOING_INIT |
| 4 | S_INIT_INIT | S_INIT_INIT |
| 5 | S_INIT_INIT_STDBY | S_INIT_INIT_STDBY |
| 6 | S_INIT_GOING_RDY_AINIT | S_INIT_GOING_RDY_AINIT |
| 7 | S_INIT_RDY_AINIT | S_INIT_RDY_AINIT |
| 8 | S_INIT_GOING_RDY_AINIT_STDBY | S_INIT_GOING_RDY_AINIT_STDBY |
| 9 | S_INIT_RDY_AINIT_STDBY | S_INIT_RDY_AINIT_STDBY |
| 10 | T_13_GOING_RDY4DRIVE | T_13_GOING_RDY4DRIVE |
| 11 | T_19_GOING_ANGLE_INIT | T_19_GOING_ANGLE_INIT |
| 12 | S_WAIT_FOR_RLW_SET | S_WAIT_FOR_RLW_SET |
| 13 | T_4_GOING_RDY4DRIVE | T_4_GOING_RDY4DRIVE |
| 14 | S_READY_FOR_DRIVE | S_READY_FOR_DRIVE |
| 15 | T_1_RDY4DRV_2_DRIVE | T_1_RDY4DRV_2_DRIVE |
| 18 | T_1_28_29_GOING_RDY4DRIVE_STDBY | T_1_28_29_GOING_RDY4DRIVE_STDBY |
| 19 | S_RDY4DRIVE_STDBY | S_RDY4DRIVE_STDBY |
| 20 | T_9_RDY4DRIVE_STDBY_2_DRVDOWN | T_9_RDY4DRIVE_STDBY_2_DRVDOWN |
| 21 | S_DRIVE | S_DRIVE |
| 22 | T_27_DRIVE_2_ACTIVEDIAG | T_27_DRIVE_2_ACTIVEDIAG |
| 23 | T_3_DRIVE_2_STANDBY | T_3_DRIVE_2_STANDBY |
| 25 | T_25_ACTIVEDIAG_2_STANDBY | T_25_ACTIVEDIAG_2_STANDBY |
| 26 | S_DRIVE_STANDBY | S_DRIVE_STANDBY |
| 30 | T_8_STANDBY_2_DRVDOWN | T_8_STANDBY_2_DRVDOWN |
| 32 | S_DRIVE_RAMP_ZERO | S_DRIVE_RAMP_ZERO |
| 33 | T_15_RAMPZERO_2_ERROR | T_15_RAMPZERO_2_ERROR |
| 34 | S_DRIVE_ACTIVEDIAG | S_DRIVE_ACTIVEDIAG |
| 35 | S_POSTRUN_DRVDOWN | S_POSTRUN_DRVDOWN |
| 36 | S_POSTRUN_GOING_POSTRUN | S_POSTRUN_GOING_POSTRUN |
| 37 | S_POSTRUN_POSTRUN | S_POSTRUN_POSTRUN |
| 38 | S_POSTRUN_FINISHED | S_POSTRUN_FINISHED |
| 39 | S_RESET | S_RESET |
| 40 | S_POWEROFF | S_POWEROFF |
| 42 | S_ERROR | S_ERROR |
| 43 | T_36_RDY4DRV_2_STANDBY_HOLD | T_36_RDY4DRV_2_STANDBY_HOLD |
| 44 | S_DRIVE_STANDBY_HOLD | S_DRIVE_STANDBY_HOLD |
| 45 | T_31_STANDBY_HOLD_2_STANDBY | T_31_STANDBY_HOLD_2_STANDBY |
| 46 | T_30_STANDBY_2_STANDBY_HOLD | T_30_STANDBY_2_STANDBY_HOLD |
| 47 | S_INIT_GOING_POSTRUN | S_INIT_GOING_POSTRUN |
| 0xXY | *** INVALID VALUE *** | *** INVALID VALUE *** |
TAB_GSTMSTATE
Dimensions: 13 rows × 3 columns
| WERT | UWTEXT | TEXT |
|---|---|---|
| 0 | Zustand Powerdown | Zustand Powerdown |
| 1 | Zustand Initialisierung | Zustand Initialisierung |
| 2 | Zustand Bereit / Regelung inaktiv | Zustand Bereit / Regelung inaktiv |
| 3 | Zustand Warte auf MLW | Zustand Warte auf MLW |
| 4 | Zustand Bereit / Regelung aktiv | Zustand Bereit / Regelung aktiv |
| 5 | Zustand Rückstellung auf Null | Zustand Rückstellung auf Null |
| 6 | Zustand Diagnose | Zustand Diagnose |
| 7 | Zustand Normalbetrieb | Zustand Normalbetrieb |
| 8 | Zustand Fehler | Zustand Fehler |
| 9 | Zustand Nachlauf | Zustand Nachlauf |
| 10 | Zustand Reset | Zustand Reset |
| 11 | Zustand Position halten | Zustand Position halten |
| 0xXY | *** Wert ungültig *** | *** Wert ungültig *** |
TAB_MLWSTATE
Dimensions: 5 rows × 3 columns
| WERT | UWTEXT | TEXT |
|---|---|---|
| 0 | Ungültig | Ungültig |
| 1 | Gültig | Gültig |
| 2 | Initialisierung | Initialisierung |
| 3 | Defekt | Defekt |
| 0xXY | *** Wert ungültig *** | *** Wert ungültig *** |
TAB_PDUSTATE
Dimensions: 6 rows × 3 columns
| WERT | UWTEXT | TEXT |
|---|---|---|
| 0 | i. O. | i. O. |
| 1 | Bus asynchron | Bus asynchron |
| 2 | Keine neuen Daten | Keine neuen Daten |
| 3 | Nicht empfangen | Nicht empfangen |
| 0xff | Hardwarefehler | Hardwarefehler |
| 0xXY | *** Wert ungültig *** | *** Wert ungültig *** |
TAB_VLTGSTATE
Dimensions: 4 rows × 3 columns
| WERT | UWTEXT | TEXT |
|---|---|---|
| 0 | i. O. | i. O. |
| 1 | Unterspannung | Unterspannung |
| 2 | Überspannung | Überspannung |
| 0xXY | *** Wert ungültig *** | *** Wert ungültig *** |
TAB_STMCM
Dimensions: 7 rows × 3 columns
| WERT | UWTEXT | TEXT |
|---|---|---|
| 0 | Keine | Keine |
| 1 | Reversible Abschaltung | Reversible Abschaltung |
| 2 | Rückstellen auf Null | Rückstellen auf Null |
| 3 | MLW Ungültig setzen | MLW Ungültig setzen |
| 4 | Bedingte Abschaltung | Bedingte Abschaltung |
| 5 | Irreversible Abschaltung | Irreversible Abschaltung |
| 0xXY | *** Wert ungültig *** | *** Wert ungültig *** |
TAB_ADSTATE
Dimensions: 7 rows × 3 columns
| WERT | UWTEXT | TEXT |
|---|---|---|
| 0 | Keine | Keine |
| 1 | Abgeschlossen | Abgeschlossen |
| 2 | Verweigert | Verweigert |
| 3 | Angehalten | Angehalten |
| 4 | Fehler (FS lesen) | Fehler (FS lesen) |
| 5 | Läuft | Läuft |
| 0xXY | *** Wert ungültig *** | *** Wert ungültig *** |
TAB_QUTARSTEA
Dimensions: 9 rows × 3 columns
| WERT | UWTEXT | TEXT |
|---|---|---|
| 0x80 | Initialisierung | Initialisierung |
| 0x20 | Sollwert umsetzen / set active | Sollwert umsetzen / set active |
| 0x24 | Sollwert umsetzen, Diagnose / set active | Sollwert umsetzen, Diagnose / set active |
| 0xe0 | Sollwert nicht umsetzen, Standby / set no active | Sollwert nicht umsetzen, Standby / set no active |
| 0xe4 | Sollwert nicht umsetzen, Diagnose / set no active | Sollwert nicht umsetzen, Diagnose / set no active |
| 0x60 | Sollwert nicht umsetzen, Fehler | Sollwert nicht umsetzen, Fehler |
| 0x70 | Sollwert nicht vorhanden | Sollwert nicht vorhanden |
| 0xff | Signal ungültig | Signal ungültig |
| 0xXY | *** Wert ungültig *** | *** Wert ungültig *** |
TAB_STECUICM
Dimensions: 17 rows × 3 columns
| WERT | UWTEXT | TEXT |
|---|---|---|
| 0x0 | Zustand Initialisierung | Zustand Initialisierung |
| 0x1 | Zustand Normalbetrieb | Zustand Normalbetrieb |
| 0x2 | Zustand Normalbetrieb/Überspannung sensiert | Zustand Normalbetrieb/Überspannung sensiert |
| 0x3 | Zustand Normalbetrieb/Unterspannung sensiert | Zustand Normalbetrieb/Unterspannung sensiert |
| 0x4 | Zustand Diagnose | Zustand Diagnose |
| 0x5 | Zustand Diagnose/Überspannung sensiert | Zustand Diagnose/Überspannung sensiert |
| 0x6 | Zustand Diagnose/Unterspannung sensiert | Zustand Diagnose/Unterspannung sensiert |
| 0x7 | Zustand Powerdown | Zustand Powerdown |
| 0x8 | Zustand PowerSave | Zustand PowerSave |
| 0x9 | Zustand Nicht verfügbar | Zustand Nicht verfügbar |
| 0xa | Zustand Reset | Zustand Reset |
| 0xb | Zustand Reserviert 11 | Zustand Reserviert 11 |
| 0xc | Zustand Reserviert 12 | Zustand Reserviert 12 |
| 0xd | Zustand Reserviert 13 | Zustand Reserviert 13 |
| 0xe | Zustand Reserviert 14 | Zustand Reserviert 14 |
| 0xf | Signal ungültig | Signal ungültig |
| 0xXY | *** Wert ungültig *** | *** Wert ungültig *** |
RES_0X4100
Dimensions: 13 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_SW_B_AKT_AKTIV | 0/1 | - | unsigned char | - | - | - | - | - | Aktivierung des Aktuators |
| STAT_SW_B_INITPROZESS | 0/1 | - | unsigned char | - | - | - | - | - | Bestimmung des Nullpunkt-Offsets |
| STAT_SW_B_AKT_DR_POS_LW | 0/1 | - | unsigned char | - | - | - | - | - | Drehrichtung für den positiven Winkel |
| STAT_SW_I_FESTUSCFG | 0-n | - | unsigned char | - | - | - | - | - | Aktivierung der Festusbotschaften |
| STAT_SW_I_KINEMATIKVARIANTE | 0-n | - | unsigned char | - | - | - | - | - | Hinterachskinematik |
| STAT_SW_I_MAX_LW_HA | 0-n | - | unsigned char | - | - | - | - | - | Maximaler Stellwinkel |
| STAT_SW_I_AKTUATORTYPE | 0-n | - | unsigned char | - | - | - | - | - | Hardwaremuster des Aktuators |
| STAT_SW_I_SPINDELSTEIGUNG | 0-n | - | unsigned char | - | - | - | - | - | Spindelsteigung |
| STAT_SKE_i_CPar_XDrive | 0-n | - | unsigned char | - | - | - | - | - | SKE Parameter |
| STAT_SKE_i_CPar_KE | 0-n | - | unsigned char | - | - | - | - | - | SKE Parameter |
| STAT_SKE_i_CPar_HS | 0-n | - | unsigned char | - | - | - | - | - | SKE Parameter |
| STAT_SKE_i_CPar_DSC | 0-n | - | unsigned char | - | - | - | - | - | SKE Parameter |
| STAT_SKE_i_CPar_SKE | 0-n | - | unsigned char | - | - | - | - | - | SKE Parameter |
TAB_KFC
Dimensions: 211 rows × 2 columns
| WERT | UWTEXT |
|---|---|
| 0 | ERRHDL_NO_KFC |
| 1 | KFC_PRG_SW |
| 2 | KFC_ACLNX_MASSCNTR_ACLNY_MASSCNTR |
| 3 | KFC_ACLNZ_COG_VYAW_VEH |
| 4 | KFC_AVL_STEA_FTAX |
| 5 | KFC_US |
| 6 | KFC_SMCURR |
| 7 | KFC_SMPOS |
| 8 | KFC_V_VEH |
| 9 | KFC_HGLV_VEH |
| 10 | KFC_SELFLOCK_UNDERVOLTAGE |
| 11 | KFC_ZFLS_UNDERVOLT |
| 12 | KFC_ADC |
| 13 | KFC_SMPOS_INIT |
| 14 | KFC_STAT_ZV_KLAPPEN |
| 15 | KFC_AVL_BRTORQ_SUM_ST_PRMSN_IBRK |
| 16 | KFC_KLD |
| 17 | KFC_DRIVER |
| 18 | KFC_ELMCSI |
| 19 | KFC_SELFLOCK |
| 20 | KFC_ST_STAB_DSC |
| 21 | KFC_AVL_RPM_WHL |
| 22 | KFC_WMOM_DRV_1 |
| 23 | KFC_AVL_QUAN_EES_WHL |
| 24 | KFC_TORQ_CRSH_1_ANG_ACPD |
| 25 | KFC_SKEIS_FLANKENZYKLUS |
| 26 | KFC_SKEIS_FLANKENZAHL |
| 27 | KFC_SKEIS_RDZ_ZYKLUS |
| 28 | KFC_SKEIS_HS |
| 29 | KFC_SKEIS_HS_KODIERUNG |
| 30 | KFC_KLD_MINI |
| 33 | KFC_WRONG_KFC_FROM_ZFLS |
| 34 | KFC_S12_AGB_LOCK |
| 35 | KFC_WAIT_FOR_RLW_SET |
| 36 | KFC_SENS_SLGS |
| 37 | KFC_TAR_STEA_MSG |
| 38 | KFC_FR_FLX |
| 39 | KFC_FR_CC |
| 40 | KFC_FR_KLEMMEN |
| 41 | KFC_TAR_STEA_MAXTIMEOUTSPOR |
| 42 | KFC_MAXAKTDIFF |
| 43 | KFC_CODING_DATA_OUT_OF_BOUNDS_NEC |
| 44 | KFC_CODING_DATA_OUT_OF_BOUNDS_S12X |
| 45 | KFC_S12X_TSA_PLAUS |
| 46 | KFC_PWR_KL30 |
| 47 | KFC_S12_STM_ERROR |
| 48 | KFC_S12_TSACTRL |
| 49 | KFC_S12_AGB_TSA |
| 50 | KFC_IPC |
| 51 | KFC_S12_IPC |
| 52 | KFC_EEPROM |
| 53 | KFC_S12_RAM |
| 54 | KFC_S12_ROM |
| 55 | KFC_STM |
| 56 | KFC_S12_WATCHDOG |
| 57 | KFC_SET_MLW_INVALID |
| 58 | KFC_REQ_RESTART |
| 59 | KFC_FLASH |
| 60 | KFC_S12_FLASH |
| 61 | KFC_S12_FR_REC |
| 62 | KFC_S12_FR_SEND |
| 63 | KFC_FR_SEND |
| 64 | KFC_TEMP |
| 65 | KFC_PWR_OUT_INIT |
| 66 | KFC_VINCOMP |
| 67 | KFC_OS_ERROR |
| 68 | KFC_WDG_1MS |
| 69 | KFC_WDG_INT |
| 70 | KFC_TAR_STEA_TIMEOUT |
| 71 | KFC_TSA_BOUND |
| 72 | KFC_HSR_ERROR |
| 73 | KFC_ENGINE_START |
| 74 | KFC_D3PDH_ILS |
| 75 | KFC_PCHARGE_OR_SSW_MOSFET_SC |
| 76 | KFC_PCHARGE_OC_OR_POWERSTAGE_SC |
| 77 | KFC_SAFETY_SWITCH_2_SC |
| 78 | KFC_SAFETY_SWITCH_1_SC |
| 79 | KFC_SSW_MOSFET_OC |
| 80 | KFC_PHASE_UZK_SC |
| 81 | KFC_PHASE_GND_SC |
| 82 | KFC_LSSW_U_OC |
| 83 | KFC_LSSW_V_OC |
| 84 | KFC_LSSW_W_OC |
| 85 | KFC_HSSW_U_OC |
| 86 | KFC_HSSW_V_OC |
| 87 | KFC_HSSW_W_OC |
| 88 | KFC_PWM3PH_INIT |
| 89 | KFC_ELMOSH_BS_UNDERVOLTAGE |
| 90 | KFC_MOTOR_OC |
| 91 | KFC_TOFF |
| 92 | KFC_KL30_UNDERVOLTAGE |
| 93 | KFC_KL30_OVERVOLTAGE |
| 94 | KFC_KL15_UNDERVOLTAGE |
| 95 | KFC_KL15_OVERVOLTAGE |
| 96 | KFC_ANALOG_SIGNALS_NOT_VALID |
| 97 | KFC_OFFSET_CALIB_FAILED |
| 98 | KFC_ELMOSH_S_E_LINK |
| 99 | KFC_ELMOSH_S_E_SPIBUF_OVL |
| 100 | KFC_ELMOSH_S_E_TIMEOUT |
| 101 | KFC_ELMOSH_UNDERVOLTAGE |
| 102 | KFC_ELMOSH_OVERCURRENT |
| 103 | KFC_ELMOSH_FAULTPIN_LOW |
| 104 | KFC_5V0A_UNDERVOLTAGE |
| 105 | KFC_3V3A_2_UNDERVOLTAGE |
| 106 | KFC_VERS_SLS |
| 107 | KFC_VERS_MLS |
| 108 | KFC_MOTORPHASE_OC |
| 109 | KFC_RLS_SIN |
| 110 | KFC_RLS_COS |
| 111 | KFC_S12_RLS_SIN |
| 112 | KFC_S12_RLS_COS |
| 113 | KFC_RLS_ABS |
| 114 | KFC_RLS_ABS_SLOW |
| 115 | KFC_RAM |
| 116 | KFC_ROM |
| 117 | KFC_S12_OS |
| 118 | KFC_DISCHARGE |
| 119 | KFC_WACKEL |
| 120 | KFC_TAR_STEA_MAXTIMEOUTSTBY |
| 121 | KFC_ELMOS_ON |
| 122 | KFC_VINTIMEOUT |
| 123 | KFC_ZWK |
| 124 | KFC_SSW_OFF |
| 125 | KFC_PPROT |
| 126 | KFC_S12_AGB_LIMIT |
| 127 | KFC_ACTIVE_DIAG |
| 128 | KFC_RLS_OFFSET_ADAPT |
| 129 | KFC_S12_RLS_OFFSET_ADAPT |
| 130 | KFC_S12_RLS_COMPARE |
| 131 | KFC_TSENSOR |
| 132 | KFC_DM_TEST_COM |
| 133 | KFC_DM_EVENT_ZEITBOTSCHAFTTIMEOUT |
| 134 | KFC_DM_TEST_APPL |
| 135 | KFC_CODING_EVENT_NOT_CODED |
| 136 | KFC_VSM_EVENT_OPMODE |
| 137 | KFC_CODING_EVENT_SIGNATURE_ERROR |
| 138 | KFC_CODING_EVENT_WRONG_VEHICLE |
| 139 | KFC_CODING_EVENT_TRANSACTION_FAILED |
| 140 | KFC_CODING_EVENT_INVALID_DATA |
| 141 | KFC_DM_Queue_DELETED |
| 142 | KFC_DM_Queue_FULL |
| 143 | KFC_NVM_E_WRITE_FAILED |
| 144 | KFC_NVM_E_READ_FAILED |
| 145 | KFC_NVM_E_CONTROL_FAILED |
| 146 | KFC_NVM_E_ERASE_FAILED |
| 147 | KFC_NVM_E_READ_ALL_FAILED |
| 148 | KFC_NVM_E_WRITE_ALL_FAILED |
| 149 | KFC_NVM_E_WRONG_CONFIG_ID |
| 150 | KFC_SW_WARNING |
| 151 | KFC_INFO_ZWK_UNDERVOLTAGE |
| 152 | KFC_INFO_ZWK_PL_UNDERVOLTAGE |
| 153 | KFC_INFO_ZWK_OVERVOLTAGE |
| 154 | KFC_INFO_ZWK_PL_OVERVOLTAGE |
| 155 | KFC_INFO_ZWK_LONG_PL |
| 156 | KFC_INFO_FRPHYS |
| 157 | KFC_FRPHYS |
| 158 | KFC_INFO_FRPHYS_STATUS_UP |
| 159 | KFC_FRPHYS_SPI |
| 160 | KFC_FRPHYS_INIT |
| 161 | KFC_INFO_FRPHYS_REINIT |
| 162 | KFC_NO_SERVICE_ICM |
| 163 | KFC_NO_SERVICE_KL |
| 164 | KFC_TORQUE |
| 165 | KFC_SLGS_NOSIGNAL_PWM |
| 166 | KFC_SLGS_NOSIGNAL_PWMK |
| 167 | KFC_SLGS_NOSIGNAL_PWM_TIMEOUT |
| 168 | KFC_SLGS_NOSIGNAL_PWMK_TIMEOUT |
| 169 | KFC_SLGS_STARTUP_PWM |
| 170 | KFC_SLGS_STARTUP_PWMK |
| 171 | KFC_SLGS_STARTUP_PWM_TIMEOUT |
| 172 | KFC_SLGS_STARTUP_PWMK_TIMEOUT |
| 173 | KFC_SLGS_FREQ |
| 174 | KFC_SLGS_DC |
| 175 | KFC_SLGS_DCM_OVERFLOW |
| 176 | KFC_STM_LOW_VLTG4DRIVE |
| 177 | KFC_TSA_MAX |
| 178 | KFC_VERS_SLS_KL15 |
| 179 | KFC_SKE_SCHED_RADDREHZAHLEN |
| 180 | KFC_SKE_SCHED_COUNTER |
| 181 | KFC_SKE_SCHED_HOEHENSTAND |
| 182 | KFC_SKE_ALIVE_FLANKEN |
| 183 | KFC_SKE_ALIVE_RADDREHZAHLENZ1 |
| 184 | KFC_SKE_ALIVE_RADDREHZAHLENZ2 |
| 185 | KFC_SKE_SIGERR_FUNKTION |
| 186 | KFC_KL15N_POSTRUN |
| 187 | KFC_KL15_OFF |
| 188 | KFC_PRG_SW_ACTSTM |
| 189 | KFC_S12_SCHED_IRQ_OVL_PIT1 |
| 190 | KFC_S12_SCHED_IRQ_OVL_SWT7 |
| 191 | KFC_S12_SCHED_NOMSG_IPC123 |
| 192 | KFC_S12_SCHED_IPC_SEND |
| 193 | KFC_SLGS_INACTIVITY_PWM |
| 194 | KFC_SLGS_INACTIVITY_PWMK |
| 195 | KFC_LOW_VLTG_SUPRESS_LONG |
| 196 | KFC_SKE_SCHED_HOEHENSTAND_LL |
| 197 | KFC_SKE_SCHED_RADDREHZAHLEN_LL |
| 198 | KFC_INFO_ZWK_EON |
| 199 | KFC_VSM_EVENT_VEHICLESTATE |
| 200 | KFC_S12_PRG_SW_ACTSTM |
| 201 | KFC_SLGS_INFO_EVTCNT |
| 202 | KFC_SLGS_INFO_DCM |
| 203 | KFC_SLGS_INFO_CAP |
| 204 | KFC_SLGS_INFO_SUPTIME |
| 205 | KFC_SLGS_INFO_TIME |
| 206 | KFC_SLGS_INFO_LASTPWM |
| 207 | KFC_SLGS_INFO_LASTPWMK |
| 208 | KFC_BIST_INFO_RESTART |
| 209 | KFC_HWOPT |
| 210 | KFC_S12_HWOPT |
| 211 | KFC_ACTIVEDIAG_DISALLOWED |
| 0xXY | *** INVALID VALUE *** |
TAB_KFA
Dimensions: 184 rows × 2 columns
| WERT | UWTEXT |
|---|---|
| 0 | KFA_GEN |
| 1 | KFA_SCP |
| 2 | KFA_SCM |
| 3 | KFA_OC |
| 4 | KFA_SCPOC |
| 5 | KFA_SCMOC |
| 6 | KFA_THI |
| 7 | KFA_TLOW |
| 8 | KFA_NCHA |
| 9 | KFA_TMCHA |
| 10 | KFA_WREL |
| 11 | KFA_PLAUS |
| 24 | KFA_STTOHI |
| 25 | KFA_STTOLO |
| 27 | KFA_OFFSET |
| 28 | KFA_COMM_ERR |
| 29 | KFA_PROG |
| 30 | KFA_SHU_OV_CURR |
| 31 | KFA_TRA_OV_CURR |
| 32 | KFA_BOOT_UN_VOLT |
| 33 | KFA_RESET_FLAG |
| 34 | KFA_ROT_SENS_VAL |
| 35 | KFA_ANGLE_CORR |
| 36 | KFA_SLOT_FINDER |
| 37 | KFA_RED_ROT_SENS_VAL |
| 38 | KFA_BRAKE_TLOW |
| 39 | KFA_DISCHARGE_ELMOS |
| 40 | KFA_DISCHARGE |
| 41 | KFA_BRAKE_HS |
| 42 | KFA_BRAKE_LS |
| 43 | KFA_BRAKE_OPEN |
| 44 | KFA_SLOTFINDER |
| 45 | KFA_BRAKE_ELCTRICAL_TEST |
| 46 | KFA_ELMOS_DRV |
| 47 | KFA_CURR_OFFSET |
| 48 | KFA_BRAKE_HOLD |
| 49 | KFA_STM |
| 50 | KFA_ELMOS_RELAIS |
| 51 | KFA_BRAKE_RELAIS |
| 52 | KFA_THI_OFF |
| 53 | KFA_STTOHI_OFF |
| 54 | KFA_STM_PLAUS |
| 55 | KFA_OVERVOLT |
| 56 | KFA_LOCK_VLT |
| 70 | KFA_ASYNC |
| 71 | KFA_TIMEOUT |
| 72 | KFA_SIG_QU_AVL_STEA |
| 73 | KFA_SIG_AVL_STEA |
| 74 | KFA_SIG_QU_SER_CTR_STE |
| 75 | KFA_SIG_ST_ECU_ST_STE |
| 76 | KFA_SIG_QU_TAR_STEA_ACT |
| 77 | KFA_INVALID_INTERRUPT |
| 80 | KFA_CODING_DATA_STELLMOTOR_VARIANTE |
| 81 | KFA_CODING_DATA_ZM |
| 82 | KFA_CODING_DATA_ZD |
| 83 | KFA_CODING_DATA_CHANGED |
| 84 | KFA_CODING_DATA_SW_I_MAX_LW_HA |
| 85 | KFA_CODING_DATA_TRANS_POS |
| 87 | KFA_MAX_DIFF_STE_ANGLE |
| 88 | KFA_TARSTEAMAXTIMEOUTS |
| 89 | KFA_NO_ENGINE_RUN |
| 90 | KFA_VSM_STM_STATE_INVALID |
| 92 | KFA_NO_DATA |
| 94 | KFA_DATA_NOT_VALID |
| 95 | KFA_ORDER |
| 96 | KFA_PARITY |
| 99 | KFA_COS_OVERFLOW |
| 100 | KFA_SIN_OVERFLOW |
| 101 | KFA_COS_UNDERFLOW |
| 102 | KFA_SIN_UNDERFLOW |
| 103 | KFA_PROM |
| 104 | KFA_RAM |
| 105 | KFA_PROM_ORDER |
| 106 | KFA_TOO_SOON |
| 107 | KFA_CRC |
| 108 | KFA_HWM |
| 109 | KFA_ALV |
| 110 | KFA_NO_MSG |
| 111 | KFA_KL_CRC |
| 112 | KFA_KL_ALV |
| 113 | KFA_MLW_INV_FROM_ICM |
| 114 | KFA_MLW_INV_FROM_DIAG |
| 115 | KFA_SIG_PDUSTSTENEC2S12X_OLD |
| 116 | KFA_SIG_PDUSTS12X2NEC_OLD |
| 120 | KFA_ERRQUEUE_WAIT4S12X |
| 125 | KFA_SW_ERRHDL_SUSPENDED_TWICE |
| 126 | KFA_SW_ERRHDL_INVALID_DEM_EVENT |
| 127 | KFA_SW_ERRHDL_QUEUE_SUSPENDED |
| 128 | KFA_SW_STM_APPL_C |
| 129 | KFA_SW_ERRHDL_MATRIX_C |
| 130 | KFA_SW_STM_ABSTRACTION_C |
| 131 | KFA_UNKNOWN_DID |
| 132 | KFA_SW_ERRHDL_IPC_C |
| 133 | KFA_SW_ERRHDL_C |
| 134 | KFA_UNSUPPORTED_S12X_KFC |
| 135 | KFA_SW_IPC_CONFIG |
| 136 | KFA_REC_IPC1_ALV |
| 137 | KFA_REC_IPC2_ALV |
| 138 | KFA_REC_IPC3_ALV |
| 139 | KFA_ALIVE_TAR_STEA_INV |
| 140 | KFA_TAR_STEA_ACT_INV |
| 141 | KFA_QUAL_TAR_STEA_INV |
| 142 | KFA_FIL_TIME_CONST_INV |
| 143 | KFA_SW_TSACTRL_C |
| 144 | KFA_1MS |
| 145 | KFA_KLD5MS |
| 146 | KFA_WPAT |
| 147 | KFA_STAB |
| 148 | KFA_PAT |
| 149 | KFA_ECC |
| 150 | KFA_CRC_1 |
| 151 | KFA_CRC_2 |
| 152 | KFA_STACK_OVL |
| 153 | KFA_STKCK_CFG |
| 154 | KFA_STKCK_NOINIT |
| 155 | KFA_MON |
| 156 | KFA_BIST |
| 157 | KFA_FAST |
| 158 | KFA_SLOW |
| 159 | KFA_INTEGRAL |
| 160 | KFA_ZWK |
| 161 | KFA_PRELOAD_TIMEOUT |
| 162 | KFA_OS_ABNORMAL_SHUTDOWN |
| 163 | KFA_OS_TT_ERROR_HOOK |
| 164 | KFA_LOW_VLTG |
| 165 | KFA_MLW_INVALID |
| 166 | KFA_INITIATE_SHUTDOWN |
| 167 | KFA_ZKH |
| 168 | KFA_10MS |
| 169 | KFA_50MS |
| 170 | KFA_KLD_SPD_UPPER |
| 171 | KFA_KLD_SPD_LOWER |
| 172 | KFA_KLD_POS_UPPER |
| 173 | KFA_KLD_POS_LOWER |
| 174 | KFA_KLD_MINI_5MS |
| 175 | KFA_KLD_MINI_50MS |
| 185 | KFA_STD_CORE |
| 187 | KFA_ERRORVALUE |
| 188 | KFA_SIGNALERROR |
| 189 | KFA_ZWK2 |
| 190 | KFA_ZWK3 |
| 191 | KFA_FRPHYS |
| 192 | KFA_NOINIT |
| 193 | KFA_BD_STATUS_UP |
| 194 | KFA_BD_STATUS_ERR |
| 195 | KFA_SPI1 |
| 196 | KFA_SPI2 |
| 197 | KFA_FAILED |
| 198 | KFA_DELAYED |
| 199 | KFA_SPI3 |
| 200 | KFA_SPI4 |
| 201 | KFA_SIG_LO |
| 202 | KFA_SIG_HI |
| 203 | KFA_DC_LOW |
| 204 | KFA_DC_HIGH |
| 205 | KFA_DC_SOFT_ERR |
| 206 | KFA_FREQ_LO |
| 207 | KFA_FREQ_HI |
| 208 | KFA_FREQ_INVALID |
| 209 | KFA_LWSPWM |
| 210 | KFA_MAX_BUS |
| 211 | KFA_MAX_TSACTRL |
| 212 | KFA_TASK_10MS / KFA_SKE_LL |
| 213 | KFA_SKE_HL |
| 214 | KFA_IPC1 |
| 215 | KFA_IPC2 |
| 216 | KFA_IPC30 |
| 217 | KFA_IPC31 |
| 218 | KFA_HWEL_INVALID |
| 219 | KFA_HWEL_UNKNOWN |
| 220 | KFA_HWEL_INV_UNKNOWN |
| 221 | KFA_AGB |
| 222 | KFA_TORQUE |
| 246 | KFA_UNKNOWN_KFA |
| 247 | KFA_ERFLAG |
| 248 | KFA_ADFROZEN |
| 249 | KFA_DXSERVER |
| 250 | KFA_VERIFY |
| 251 | KFA_POS_ERR |
| 252 | KFA_SPEED_ERR |
| 253 | KFA_GEN2 |
| 254 | KFA_NO_ERROR |
| 255 | KFA_MAX |
| 0xXY | *** INVALID VALUE *** |
RES_0X4101
Dimensions: 64 rows × 10 columns
| RESULTNAME | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|
| STAT_P_WERT | - | - | unsigned char | - | - | - | - | - | Zeiger auf den letzten Ringspeichereintrag (RS) |
| STAT_ZKJ_WERT | - | - | unsigned int | - | - | - | - | - | Zähler wie oft eine Schneekette erkannt wurde (seit Reset Ringspeicher) |
| STAT_ZKU_WERT | - | - | unsigned int | - | - | - | - | - | Zähler wie oft keine sichere Entscheidung getroffen werden konnte (entspricht keine Schneekette erkannt) |
| STAT_ZKE_WERT | - | - | unsigned long | - | - | - | - | - | Zähler wie oft eine Entscheidung getroffen werden konnte (entspricht Anzahl Erkennungsvorgänge) |
| STAT_KMS_00_WERT | km | - | unsigned long | - | - | - | - | - | Kilometerstand RS-00 |
| STAT_AV_00_WERT | hex | - | unsigned int | - | - | - | - | - | Aktivierte Erkennungsverfahren RS-00 |
| STAT_VS_00_WERT | hex | - | unsigned int | - | - | - | - | - | Verfügbare Signale RS-00 |
| STAT_KE_00_WERT | hex | - | unsigned char | - | - | - | - | - | Erkannte Erkennungsverfahren RS-00 |
| STAT_KMS_01_WERT | km | - | unsigned long | - | - | - | - | - | Kilometerstand RS-01 |
| STAT_AV_01_WERT | hex | - | unsigned int | - | - | - | - | - | Aktivierte Erkennungsverfahren RS-01 |
| STAT_VS_01_WERT | hex | - | unsigned int | - | - | - | - | - | Verfügbare Signale RS-01 |
| STAT_KE_01_WERT | hex | - | unsigned char | - | - | - | - | - | Erkannte Erkennungsverfahren RS-01 |
| STAT_KMS_02_WERT | km | - | unsigned long | - | - | - | - | - | Kilometerstand RS-02 |
| STAT_AV_02_WERT | hex | - | unsigned int | - | - | - | - | - | Aktivierte Erkennungsverfahren RS-02 |
| STAT_VS_02_WERT | hex | - | unsigned int | - | - | - | - | - | Verfügbare Signale RS-02 |
| STAT_KE_02_WERT | hex | - | unsigned char | - | - | - | - | - | Erkannte Erkennungsverfahren RS-02 |
| STAT_KMS_03_WERT | km | - | unsigned long | - | - | - | - | - | Kilometerstand RS-03 |
| STAT_AV_03_WERT | hex | - | unsigned int | - | - | - | - | - | Aktivierte Erkennungsverfahren RS-03 |
| STAT_VS_03_WERT | hex | - | unsigned int | - | - | - | - | - | Verfügbare Signale RS-03 |
| STAT_KE_03_WERT | hex | - | unsigned char | - | - | - | - | - | Erkannte Erkennungsverfahren RS-03 |
| STAT_KMS_04_WERT | km | - | unsigned long | - | - | - | - | - | Kilometerstand RS-04 |
| STAT_AV_04_WERT | hex | - | unsigned int | - | - | - | - | - | Aktivierte Erkennungsverfahren RS-04 |
| STAT_VS_04_WERT | hex | - | unsigned int | - | - | - | - | - | Verfügbare Signale RS-04 |
| STAT_KE_04_WERT | hex | - | unsigned char | - | - | - | - | - | Erkannte Erkennungsverfahren RS-04 |
| STAT_KMS_05_WERT | km | - | unsigned long | - | - | - | - | - | Kilometerstand RS-05 |
| STAT_AV_05_WERT | hex | - | unsigned int | - | - | - | - | - | Aktivierte Erkennungsverfahren RS-05 |
| STAT_VS_05_WERT | hex | - | unsigned int | - | - | - | - | - | Verfügbare Signale RS-05 |
| STAT_KE_05_WERT | hex | - | unsigned char | - | - | - | - | - | Erkannte Erkennungsverfahren RS-05 |
| STAT_KMS_06_WERT | km | - | unsigned long | - | - | - | - | - | Kilometerstand RS-06 |
| STAT_AV_06_WERT | hex | - | unsigned int | - | - | - | - | - | Aktivierte Erkennungsverfahren RS-06 |
| STAT_VS_06_WERT | hex | - | unsigned int | - | - | - | - | - | Verfügbare Signale RS-06 |
| STAT_KE_06_WERT | hex | - | unsigned char | - | - | - | - | - | Erkannte Erkennungsverfahren RS-06 |
| STAT_KMS_07_WERT | km | - | unsigned long | - | - | - | - | - | Kilometerstand RS-07 |
| STAT_AV_07_WERT | hex | - | unsigned int | - | - | - | - | - | Aktivierte Erkennungsverfahren RS-07 |
| STAT_VS_07_WERT | hex | - | unsigned int | - | - | - | - | - | Verfügbare Signale RS-07 |
| STAT_KE_07_WERT | hex | - | unsigned char | - | - | - | - | - | Erkannte Erkennungsverfahren RS-07 |
| STAT_KMS_08_WERT | km | - | unsigned long | - | - | - | - | - | Kilometerstand RS-08 |
| STAT_AV_08_WERT | hex | - | unsigned int | - | - | - | - | - | Aktivierte Erkennungsverfahren RS-08 |
| STAT_VS_08_WERT | hex | - | unsigned int | - | - | - | - | - | Verfügbare Signale RS-08 |
| STAT_KE_08_WERT | hex | - | unsigned char | - | - | - | - | - | Erkannte Erkennungsverfahren RS-08 |
| STAT_KMS_09_WERT | km | - | unsigned long | - | - | - | - | - | Kilometerstand RS-09 |
| STAT_AV_09_WERT | hex | - | unsigned int | - | - | - | - | - | Aktivierte Erkennungsverfahren RS-09 |
| STAT_VS_09_WERT | hex | - | unsigned int | - | - | - | - | - | Verfügbare Signale RS-09 |
| STAT_KE_09_WERT | hex | - | unsigned char | - | - | - | - | - | Erkannte Erkennungsverfahren RS-09 |
| STAT_KMS_10_WERT | km | - | unsigned long | - | - | - | - | - | Kilometerstand RS-10 |
| STAT_AV_10_WERT | hex | - | unsigned int | - | - | - | - | - | Aktivierte Erkennungsverfahren RS-10 |
| STAT_VS_10_WERT | hex | - | unsigned int | - | - | - | - | - | Verfügbare Signale RS-10 |
| STAT_KE_10_WERT | hex | - | unsigned char | - | - | - | - | - | Erkannte Erkennungsverfahren RS-10 |
| STAT_KMS_11_WERT | km | - | unsigned long | - | - | - | - | - | Kilometerstand RS-11 |
| STAT_AV_11_WERT | hex | - | unsigned int | - | - | - | - | - | Aktivierte Erkennungsverfahren RS-11 |
| STAT_VS_11_WERT | hex | - | unsigned int | - | - | - | - | - | Verfügbare Signale RS-11 |
| STAT_KE_11_WERT | hex | - | unsigned char | - | - | - | - | - | Erkannte Erkennungsverfahren RS-11 |
| STAT_KMS_12_WERT | km | - | unsigned long | - | - | - | - | - | Kilometerstand RS-12 |
| STAT_AV_12_WERT | hex | - | unsigned int | - | - | - | - | - | Aktivierte Erkennungsverfahren RS-12 |
| STAT_VS_12_WERT | hex | - | unsigned int | - | - | - | - | - | Verfügbare Signale RS-12 |
| STAT_KE_12_WERT | hex | - | unsigned char | - | - | - | - | - | Erkannte Erkennungsverfahren RS-12 |
| STAT_KMS_13_WERT | km | - | unsigned long | - | - | - | - | - | Kilometerstand RS-13 |
| STAT_AV_13_WERT | hex | - | unsigned int | - | - | - | - | - | Aktivierte Erkennungsverfahren RS-13 |
| STAT_VS_13_WERT | hex | - | unsigned int | - | - | - | - | - | Verfügbare Signale RS-13 |
| STAT_KE_13_WERT | hex | - | unsigned char | - | - | - | - | - | Erkannte Erkennungsverfahren RS-13 |
| STAT_KMS_14_WERT | km | - | unsigned long | - | - | - | - | - | Kilometerstand RS-14 |
| STAT_AV_14_WERT | hex | - | unsigned int | - | - | - | - | - | Aktivierte Erkennungsverfahren RS-14 |
| STAT_VS_14_WERT | hex | - | unsigned int | - | - | - | - | - | Verfügbare Signale RS-14 |
| STAT_KE_14_WERT | hex | - | unsigned char | - | - | - | - | - | Erkannte Erkennungsverfahren RS-14 |
RES_0X4103
Dimensions: 1 rows × 13 columns
| RESULTNAME | STR | STPR | RRR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| STAT_ERROR | + | - | + | 0-n | - | unsigned char | - | TAB_EEEERR | - | - | - | tEEE_REQUEST.error |
ARG_0X4103
Dimensions: 5 rows × 14 columns
| ARG | STR | STPR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | MIN | MAX | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ARG_COMMAND | + | - | - | - | unsigned char | - | - | - | - | - | - | - | tEEE_REQUEST.command |
| ARG_ADDRESS | + | - | - | - | unsigned long | - | - | - | - | - | - | - | tEEE_REQUEST.address |
| ARG_ID | + | - | - | - | unsigned int | - | - | - | - | - | - | - | tEEE_REQUEST.identifier |
| ARG_LENGTH | + | - | - | - | unsigned int | - | - | - | - | - | - | - | tEEE_REQUEST.length |
| ARG_OFFSET | + | - | - | - | unsigned int | - | - | - | - | - | - | - | tEEE_REQUEST.offset |
TAB_EEEERR
Dimensions: 14 rows × 3 columns
| WERT | UWTEXT | TEXT |
|---|---|---|
| 0 | EEE_OK | EEE_OK |
| 1 | EEE_ERR_PARAMETER | EEE_ERR_PARAMETER |
| 2 | EEE_DRIVER_BUSY | EEE_DRIVER_BUSY |
| 3 | EEE_ERR_SECTION_FULL | EEE_ERR_SECTION_FULL |
| 4 | EEE_ERR_POOL_FULL | EEE_ERR_POOL_FULL |
| 5 | EEE_ERR_COMMAND_UNKNOWN | EEE_ERR_COMMAND_UNKNOWN |
| 6 | EEE_ERR_FLASH_ERROR | EEE_ERR_FLASH_ERROR |
| 7 | EEE_ERR_USER_ABORT | EEE_ERR_USER_ABORT |
| 8 | EEE_ERR_READ_UNKNOWNID | EEE_ERR_READ_UNKNOWNID |
| 9 | EEE_ERR_READ_OBSOLETE | EEE_ERR_READ_OBSOLETE |
| 10 | EE_ERR_NOACTIVESECTION | EE_ERR_NOACTIVESECTION |
| 11 | EEE_ERR_FLOW | EEE_ERR_FLOW |
| 12 | EEE_ERR_OPERATION_REJECTED | EEE_ERR_OPERATION_REJECTED |
| 0xXY | Wert nicht in SGBD | Wert nicht in SGBD |
RES_0X4104
Dimensions: 12 rows × 13 columns
| RESULTNAME | STR | STPR | RRR | EINHEIT | L/H | DATENTYP | MASKE | NAME | MUL | DIV | ADD | INFO |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| STAT_KRKE_E_OMEGA_WERT | - | - | - | hex | high | long | - | - | - | - | - | get_Festus_KrKE_E_omega |
| STAT_KRKE_E_HS_WERT | - | - | - | hex | high | long | - | - | - | - | - | get_Festus_KrKE_E_hs |
| STAT_KRKE_AK_OMEGA_WERT | - | - | - | hex | high | long | - | - | - | - | - | get_Festus_KrKE_AK_omega |
| STAT_KRKE_AK_OMEGA_V_WERT | - | - | - | hex | high | long | - | - | - | - | - | get_Festus_KrKE_AK_omega_V |
| STAT_KRKE_AK_HS_H_WERT | - | - | - | hex | high | long | - | - | - | - | - | get_Festus_KrKE_AK_hs_H |
| STAT_KRKE_AK_HS_V_WERT | - | - | - | hex | high | long | - | - | - | - | - | get_Festus_KrKE_AK_hs_V |
| STAT_VS_QUAL_WERT | - | - | - | hex | high | unsigned long | - | - | - | - | - | get_Festus_VS_qual |
| STAT_VM_QUAL_WERT | - | - | - | hex | high | unsigned long | - | - | - | - | - | get_Festus_VM_qual |
| STAT_LK_QUAL_WERT | - | - | - | hex | high | unsigned long | - | - | - | - | - | get_Festus_LK_qual |
| STAT_VA_QUAL_WERT | - | - | - | hex | high | unsigned long | - | - | - | - | - | get_Festus_VA_qual |
| STAT_VE_QUAL_WERT | - | - | - | hex | high | unsigned long | - | - | - | - | - | get_Festus_VE_qual |
| STAT_KE_QUAL_WERT | - | - | - | hex | high | unsigned long | - | - | - | - | - | get_Festus_KE_qual |